Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 3 de 3
Filtrar
1.
Stereotact Funct Neurosurg ; 98(4): 263-269, 2020.
Artigo em Inglês | MEDLINE | ID: mdl-32403106

RESUMO

Magnetic resonance image-guided high-intensity focused ultrasound (MRgFUS)-based thermal ablation of the ventral intermediate nucleus of the thalamus (VIM) is a minimally invasive treatment modality for essential tremor (ET). Dentato-rubro-thalamic tractography (DRTT) is becoming increasingly popular for direct targeting of the presumed VIM ablation focus. It is currently unclear if patients with implanted pulse generators (IPGs) can safely undergo MRgFUS ablation and reliably acquire DRTT suitable for direct targeting. We present an 80-year-old male with a spinal cord stimulator (SCS) and an 88-year-old male with a cardiac pacemaker who both underwent MRgFUS for medically refractory ET. Clinical outcomes were measured using the Clinical Rating Scale for Tremor (CRST). DRTT was successfully created and imaging parameter adjustments did not result in any delay in procedural time in either case. In the first case, 7 therapeutic sonications were delivered. The patient improved immediately and durably with a 90% CRST-disability improvement at 6-week follow-up. In our second case, 6 therapeutic sonications were delivered with durable, 75% CRST-disability improvement at 6 weeks. These are the first cases of MRgFUS thalamotomy in patients with IPGs. DRTT targeting and MRgFUS-based thermal ablation can be safely performed in these patients using a 1.5-T MRI.


Assuntos
Núcleos Cerebelares/diagnóstico por imagem , Neuroestimuladores Implantáveis , Marca-Passo Artificial , Núcleo Rubro/diagnóstico por imagem , Tálamo/diagnóstico por imagem , Tálamo/cirurgia , Idoso de 80 Anos ou mais , Tremor Essencial/diagnóstico por imagem , Tremor Essencial/cirurgia , Humanos , Imageamento por Ressonância Magnética/métodos , Masculino , Psicocirurgia/métodos , Estimulação da Medula Espinal/instrumentação , Resultado do Tratamento
2.
Neurosurg Focus ; 44(2): E3, 2018 02.
Artigo em Inglês | MEDLINE | ID: mdl-29385914

RESUMO

Although the use of focused ultrasound (FUS) in neurosurgery dates to the 1950s, its clinical utility was limited by the need for a craniotomy to create an acoustic window. Recent technological advances have enabled efficient transcranial delivery of US. Moreover, US is now coupled with MRI to ensure precise energy delivery and monitoring. Thus, MRI-guided transcranial FUS lesioning is now being investigated for myriad neurological and psychiatric disorders. Among the first transcranial FUS treatments is thalamotomy for the treatment of various tremors. The authors provide a technical overview of FUS thalamotomy for tremor as well as important lessons learned during their experience with this emerging technology.


Assuntos
Tremor Essencial/diagnóstico por imagem , Tremor Essencial/cirurgia , Imageamento por Ressonância Magnética/métodos , Procedimentos Neurocirúrgicos/métodos , Tálamo/diagnóstico por imagem , Tálamo/cirurgia , Humanos , Monitorização Neurofisiológica Intraoperatória/métodos , Cuidados Pós-Operatórios/métodos
3.
Oper Neurosurg (Hagerstown) ; 17(4): 376-381, 2019 10 01.
Artigo em Inglês | MEDLINE | ID: mdl-30888021

RESUMO

BACKGROUND: A recent randomized controlled trial of magnetic resonance imaging (MRI)-guided focused ultrasound (FUS) for essential tremor (ET) demonstrated safety and efficacy. Patients with ventricular shunts may be good candidates for FUS to minimize hardware-associated infections. OBJECTIVE: To demonstrate feasibility of FUS in this subset of patients. METHODS: A 74-yr-old male with medically refractory ET, and a right-sided ventricular shunt for normal pressure hydrocephalus, underwent FUS to the right ventro-intermedius (VIM) nucleus. The VIM nucleus was directly targeted using deterministic tractography. Clinical outcomes were measured using the Clinical Rating Scale for Tremor. RESULTS: Shunt components required 6% of the total ultrasound transducer elements to be shut off. Eight therapeutic sonications were delivered (maximum temperature, 64°), leading to a 90% improvement in hand tremor and a 100% improvement in functional disability at the 3-mo follow-up. No complications were noted. CONCLUSION: This is the first case of FUS thalamotomy in a patient with a shunt. Direct VIM targeting and achievement of therapeutic temperatures with acoustic energy is feasible in this subset of patients.


Assuntos
Tremor Essencial/cirurgia , Ablação por Ultrassom Focalizado de Alta Intensidade/métodos , Núcleos Ventrais do Tálamo/cirurgia , Idoso , Tremor Essencial/complicações , Humanos , Hidrocefalia de Pressão Normal/complicações , Hidrocefalia de Pressão Normal/cirurgia , Imageamento Tridimensional , Imageamento por Ressonância Magnética , Masculino , Cirurgia Assistida por Computador , Tálamo/cirurgia , Resultado do Tratamento , Derivação Ventriculoperitoneal
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA