Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 3 de 3
Filtrar
Mais filtros

Base de dados
Tipo de documento
País de afiliação
Intervalo de ano de publicação
1.
Comput Methods Biomech Biomed Engin ; 8(5): 307-13, 2005 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-16298852

RESUMO

A numerical model of the medial open wedge tibial osteotomy based on the finite element method was developed. Two plate positions were tested numerically. In a configuration, (a), the plate was fixed in a medial position and (b) in an anteromedial position. The simulation took into account soft tissues preload, muscular tonus and maximal gait load.The maximal stresses observed in the four structural elements (bone, plate, wedge, screws) of an osteotomy with plate in medial position were substantially higher (1.13-2.8 times more) than those observed in osteotomy with an anteromedial plate configuration. An important increase (1.71 times more) of the relative micromotions between the wedge and the bone was also observed. In order to avoid formation of fibrous tissue at the bone wedge interface, the osteotomy should be loaded under 18.8% (approximately 50 kg) of the normal gait load until the osteotomy interfaces union is achieved.


Assuntos
Artroplastia do Joelho/instrumentação , Artroplastia do Joelho/métodos , Placas Ósseas , Osteotomia/instrumentação , Osteotomia/métodos , Implantação de Prótese/métodos , Tíbia/fisiopatologia , Tíbia/cirurgia , Fenômenos Biomecânicos , Parafusos Ósseos , Simulação por Computador , Análise de Falha de Equipamento/métodos , Análise de Elementos Finitos , Fixação Interna de Fraturas/instrumentação , Fixação Interna de Fraturas/métodos , Humanos , Modelos Biológicos , Movimento , Estresse Mecânico , Suporte de Carga
2.
J Biomech ; 43(5): 933-7, 2010 Mar 22.
Artigo em Inglês | MEDLINE | ID: mdl-20004397

RESUMO

An analytical model of the fluid/cell mechanical interaction was developed. The interfacial shear stress, due to the coupling between the fluid and the cell deformation, was characterized by a new dimensionless number N(fs). For N(fs) above a critical value, the fluid/cell interaction had a damping effect on the interfacial shear stress. Conversely, for N(fs) below this critical value, interfacial shear stress was amplified. As illustration, the role of the dynamic fluid/cell mechanical coupling was studied in a specific biological situation involving cells seeded in a bone scaffold. For the particular bone scaffold chosen, the dimensionless number N(fs) was higher than the critical value. In this case, the dynamic shear stress at the fluid/cell interface is damped for increasing excitation frequency. Interestingly, this damping effect is correlated to the pore diameter of the scaffold, furnishing thus target values in the design of the scaffold. Correspondingly, an efficient cell stimulation might be achieved with a scaffold of pore size larger than 300 microm as no dynamic damping effect is likely to take place. The analytical model proposed in this study, while being a simplification of a fluid/cell mechanical interaction, brings complementary insights to numerical studies by analyzing the effect of different physical parameters.


Assuntos
Líquido Extracelular/fisiologia , Mecanotransdução Celular/fisiologia , Modelos Biológicos , Osteoblastos/citologia , Osteoblastos/fisiologia , Engenharia Tecidual/métodos , Alicerces Teciduais , Animais , Células Cultivadas , Simulação por Computador , Humanos , Resistência ao Cisalhamento/fisiologia
3.
J Orthop Res ; 27(8): 1082-7, 2009 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-19180634

RESUMO

Our goal was to develop a method to identify the optimal elastic modulus, Poisson's ratio, porosity, and permeability values for a mechanically stressed bone substitute. We hypothesized that a porous bone substitute that favors the transport of nutriments, wastes, biochemical signals, and cells, while keeping the fluid-induced shear stress within a range that stimulates osteoblasts, would likely promote osteointegration. Two optimization criteria were used: (i) the fluid volume exchange between the artificial bone substitute and its environment must be maximal and (ii) the fluid-induced shear stress must be between 0.03 and 3 Pa. Biot's poroelastic theory was used to compute the fluid motion due to mechanical stresses. The impact of the elastic modulus, Poisson's ratio, porosity, and permeability on the fluid motion were determined in general and for three different bone substitute sizes used in high tibial osteotomy. We found that fluid motion was optimized in two independent steps. First, fluid transport was maximized by minimizing the elastic modulus, Poisson's ratio, and porosity. Second, the fluid-induced shear stress could be adjusted by tuning the bone substitute permeability so that it stayed within the favorable range of 0.03 to 3 Pa. Such method provides clear guidelines to bone substitute developers and to orthopedic surgeons for using bone substitute materials according to their mechanical environment.


Assuntos
Substitutos Ósseos , Adulto , Simulação por Computador , Módulo de Elasticidade , Humanos , Masculino , Modelos Biológicos , Osteotomia , Permeabilidade , Porosidade , Reologia , Resistência ao Cisalhamento , Estresse Mecânico , Tíbia/cirurgia
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA