RESUMO
BACKGROUND: Targeted temperature management is recommended for patients after cardiac arrest, but the supporting evidence is of low certainty. METHODS: In an open-label trial with blinded assessment of outcomes, we randomly assigned 1900 adults with coma who had had an out-of-hospital cardiac arrest of presumed cardiac or unknown cause to undergo targeted hypothermia at 33°C, followed by controlled rewarming, or targeted normothermia with early treatment of fever (body temperature, ≥37.8°C). The primary outcome was death from any cause at 6 months. Secondary outcomes included functional outcome at 6 months as assessed with the modified Rankin scale. Prespecified subgroups were defined according to sex, age, initial cardiac rhythm, time to return of spontaneous circulation, and presence or absence of shock on admission. Prespecified adverse events were pneumonia, sepsis, bleeding, arrhythmia resulting in hemodynamic compromise, and skin complications related to the temperature management device. RESULTS: A total of 1850 patients were evaluated for the primary outcome. At 6 months, 465 of 925 patients (50%) in the hypothermia group had died, as compared with 446 of 925 (48%) in the normothermia group (relative risk with hypothermia, 1.04; 95% confidence interval [CI], 0.94 to 1.14; P = 0.37). Of the 1747 patients in whom the functional outcome was assessed, 488 of 881 (55%) in the hypothermia group had moderately severe disability or worse (modified Rankin scale score ≥4), as compared with 479 of 866 (55%) in the normothermia group (relative risk with hypothermia, 1.00; 95% CI, 0.92 to 1.09). Outcomes were consistent in the prespecified subgroups. Arrhythmia resulting in hemodynamic compromise was more common in the hypothermia group than in the normothermia group (24% vs. 17%, P<0.001). The incidence of other adverse events did not differ significantly between the two groups. CONCLUSIONS: In patients with coma after out-of-hospital cardiac arrest, targeted hypothermia did not lead to a lower incidence of death by 6 months than targeted normothermia. (Funded by the Swedish Research Council and others; TTM2 ClinicalTrials.gov number, NCT02908308.).
Assuntos
Febre/terapia , Hipotermia Induzida , Parada Cardíaca Extra-Hospitalar/terapia , Idoso , Temperatura Corporal , Reanimação Cardiopulmonar/métodos , Coma/etiologia , Coma/terapia , Feminino , Febre/etiologia , Humanos , Hipotermia Induzida/efeitos adversos , Estimativa de Kaplan-Meier , Masculino , Pessoa de Meia-Idade , Parada Cardíaca Extra-Hospitalar/complicações , Parada Cardíaca Extra-Hospitalar/mortalidade , Método Simples-Cego , Resultado do TratamentoRESUMO
BACKGROUND: There is a paucity of data on the incidence of central venous catheter tip misplacements after the implementation of ultrasound guidance during insertion. The aims of the present study were to determine the incidence of tip misplacements and to identify independent variables associated with tip misplacement. METHODS: All jugular and subclavian central venous catheter insertions in patients ≥16 years with a post-procedural chest radiography at four hospitals were included. Each case was reviewed for relevant catheter data and radiologic evaluations of chest radiographies. Tip misplacements were classified as 'any tip misplacement', 'minor tip misplacement' or 'major tip misplacement'. Multivariable logistic regression analyses were used to investigate associations between predefined independent variables and tip misplacements. RESULTS: A total of 8556 central venous catheter insertions in 5587 patients were included. Real-time ultrasound guidance was used in 91% of all insertions. Any tip misplacement occurred (95% confidence interval) in 3.7 (3.3-4.1)% of the catheterisations, and 2.1 (1.8-2.4)% were classified as major tip misplacements. The multivariable logistic regression analyses showed that female patient gender, subclavian vein insertions, number of skin punctures and limited operator experience were associated with a higher risk of major tip misplacement, whereas increasing age and height were associated with a lower risk. CONCLUSIONS: In this large prospective multicentre cohort study, performed in the ultrasound-guided era, we demonstrated the incidence of tip misplacements to be 3.7 (3.3-4.1)%. Right internal jugular vein catheterisation had the lowest incidence of both minor and major tip misplacement.
Assuntos
Cateterismo Venoso Central , Cateteres Venosos Centrais , Humanos , Feminino , Cateterismo Venoso Central/efeitos adversos , Cateteres Venosos Centrais/efeitos adversos , Estudos Prospectivos , Estudos de Coortes , Ultrassonografia , Veias Jugulares/diagnóstico por imagem , Ultrassonografia de IntervençãoRESUMO
BACKGROUND: Digital modalities which enable asynchronous learning, such as audio podcasts and videos demonstrating procedures, may benefit acquisition and retention of knowledge and clinical skills. The main objective of this nationwide cross-sectional survey study was to evaluate key aspects and factors related to usage of audio podcasts and procedural videos in anaesthesiology and intensive care. METHODS: A 20-item multiple-choice-question online survey was created through a consensus process including pilot testing among residents and consultants. Data were collected over a 3-month period, September-November 2023. RESULTS: The survey was completed by 466 anaesthetists. More than a third reported using procedural videos ≥1 time per week, whereas fewer than one in four participants used audio podcasts at least once per week. Multivariable logistic regression analysis showed that working at a university hospital, male sex, and younger age were independently associated with podcast use ≥1 time per week, with the highest odds ratio (OR) for younger age (<40 years vs. ≥40 years old; OR 5.86 (95% confidence interval 3.55-9.67), p < .001). Younger age was also significantly associated with higher frequency of video use (OR 1.71 (1.13-2.58), p = .011), while working predominantly in intensive care was associated with a lower frequency of video use. Podcasts were often used during commuting (42.3%), household work (30.7%), and exercise (24.9%), indicating a role in multi-tasking. Approximately half of respondents expressed that audio podcast-based learning has a moderate to very large positive impact on acquisition of theoretical knowledge, as well as practical skills. A vast majority, 85.2%, reported that procedural videos have a moderate to very large impact on development of clinical skills. CONCLUSION: Audio podcasts and procedural videos are appreciated tools with potential to supplement more traditional didactic techniques in anaesthesiology and intensive care. Procedural video use is common, with perceived large effects on development of clinical skills. Further data are needed to fully understand learning outcomes, quality of peer-review processes, and potential sex-differences.
Assuntos
Anestesiologia , Cuidados Críticos , Gravação em Vídeo , Webcasts como Assunto , Humanos , Masculino , Feminino , Anestesiologia/educação , Suécia , Estudos Transversais , Adulto , Pessoa de Meia-Idade , Inquéritos e Questionários , Anestesistas/estatística & dados numéricos , Competência Clínica/estatística & dados numéricosRESUMO
BACKGROUND: A previous study on mechanical complications after central venous catheterisation demonstrated differences in complication rates between male and female operators. The objective of this subgroup analysis was to further investigate these differences. The hypothesis was that differences in distribution of predefined variables between operator genders could be identified. METHODS: This was a subgroup analysis of a prospective, multicentre, observational cohort study conducted between March 2019 and December 2020 including 8 586 patients ≥ 16 years receiving central venous catheters at four emergency care hospitals. The main outcome measure was major mechanical complications defined as major bleeding, severe cardiac arrhythmia, pneumothorax, arterial catheterisation, and persistent nerve injury. Independent t-test and χ2 test were used to investigate differences in distribution of major mechanical complications and predefined variables between male and female operators. Multivariable logistic regression analysis was used to determine association between operator gender and major mechanical complications. RESULTS: Female operators had a lower rate of major mechanical complications than male operators (0.4% vs 0.8%, P = .02), were less experienced (P < .001), had more patients with invasive positive pressure ventilation (P < .001), more often chose the internal jugular vein (P < .001) and more frequently used ultrasound guidance (P < .001). Male operators more often chose the subclavian vein (P < .001) and inserted more catheters with bore size ≥ 9 Fr (P < .001). Multivariable logistic regression analysis showed that male operator gender was associated with major mechanical complication (OR 2.67 [95% CI: 1.26-5.64]) after correction for other relevant independent variables. CONCLUSIONS: The hypothesis was confirmed as differences in distribution of predefined variables between operator genders were found. Despite being less experienced, female operators had a lower rate of major mechanical complications. Furthermore, male operator gender was independently associated with a higher risk of major mechanical complications. Future studies are needed to further investigate differences in risk behaviour between male and female operators. TRIAL REGISTRATION: Clinicaltrials.gov identifier: NCT03782324. Date of registration: 20/12/2018.
Assuntos
Cateterismo Venoso Central , Cateteres Venosos Centrais , Feminino , Humanos , Masculino , Cateterismo Venoso Central/efeitos adversos , Cateteres Venosos Centrais/efeitos adversos , Veias Jugulares , Estudos Prospectivos , Fatores Sexuais , Ultrassonografia , Adolescente , Estudos Multicêntricos como Assunto , Estudos Observacionais como Assunto , AdultoRESUMO
Patients admitted to intensive care after cardiac arrest are at risk of circulatory shock and early mortality due to cardiovascular failure. The aim of this study was to evaluate the ability of the veno-arterial pCO2 difference (∆pCO2 ; central venous CO2 - arterial CO2 ) and lactate to predict early mortality in postcardiac arrest patients. This was a pre-planned prospective observational sub-study of the target temperature management 2 trial. The sub-study patients were included at five Swedish sites. Repeated measurements of ∆pCO2 and lactate were conducted at 4, 8, 12, 16, 24, 48, and 72 h after randomization. We assessed the association between each marker and 96-h mortality and their prognostic value for 96-h mortality. One hundred sixty-three patients were included in the analysis. Mortality at 96 h was 17%. During the initial 24 h, there was no difference in ∆pCO2 levels between 96-h survivors and non-survivors. ∆pCO2 measured at 4 h was associated with an increased risk of death within 96 h (adjusted odds ratio: 1.15; 95% confidence interval [CI]: 1.02-1.29; p = .018). Lactate levels were associated with poor outcome over multiple measurements. The area under the receiving operating curve to predict death within 96 h was 0.59 (95% CI: 0.48-0.74) and 0.82 (95% CI: 0.72-0.92) for ∆pCO2 and lactate, respectively. Our results do not support the use of ∆pCO2 to identify patients with early mortality in the postresuscitation phase. In contrast, non-survivors demonstrated higher lactate levels in the initial phase and lactate identified patients with early mortality with moderate accuracy.
Assuntos
Parada Cardíaca , Choque , Humanos , Ácido Láctico , Dióxido de Carbono , PrognósticoRESUMO
BACKGROUND: Limited data are available on the incidence of mechanical complications after ultrasound-guided central venous catheterisation. We aimed to determine the incidence of mechanical complications in hospitals where real-time ultrasound guidance is clinical practice for central venous access and to identify variables associated with mechanical complications. METHODS: All central venous catheter insertions in patients ≥16 yr at four emergency care hospitals in Sweden from March 2, 2019 to December 31, 2020 were eligible for inclusion. Every insertion was monitored for complete documentation and occurrence of mechanical complications within 24 h after catheterisation. Multivariable logistic regression analyses were used to determine associations between predefined variables and mechanical complications. RESULTS: In total, 12 667 catheter insertions in 8586 patients were included. The incidence (95% confidence interval [CI]) of mechanical complications was 7.7% (7.3-8.2%), of which 0.4% (0.3-0.5%) were major complications. The multivariable analyses showed that patient BMI <20 kg m-2 (odds ratio 2.69 [95% CI: 1.17-5.62]), male operator gender (3.33 [1.60-7.38]), limited operator experience (3.11 [1.64-5.77]), and increasing number of skin punctures (2.18 [1.59-2.88]) were associated with major mechanical complication. Subclavian vein catheterisation was associated with pneumothorax (5.91 [2.13-17.26]). CONCLUSIONS: The incidence of major mechanical complications is low in hospitals where real-time ultrasound guidance is the standard of care for central venous access. Several variables independently associated with mechanical complications can be used for risk stratification before catheterisation procedures, which might further reduce complication rates. CLINICAL TRIAL REGISTRATION: NCT03782324.
Assuntos
Cateterismo Venoso Central , Humanos , Masculino , Cateterismo Venoso Central/efeitos adversos , Cateterismo Venoso Central/métodos , Veias Jugulares/diagnóstico por imagem , Estudos Prospectivos , Ultrassonografia de Intervenção/métodos , UltrassonografiaRESUMO
BACKGROUND: Continuous EEG-monitoring (cEEG) in the ICU is recommended to assess prognosis and detect seizures after cardiac arrest but implementation is often limited by the lack of EEG-technicians and experts. The aim of the study was to assess ICU physicians ability to perform preliminary interpretations of a simplified cEEG in the post cardiac arrest setting. METHODS: Five ICU physicians received training in interpretation of simplified cEEG - total training duration 1 day. The ICU physicians then interpreted 71 simplified cEEG recordings from 37 comatose survivors of cardiac arrest. The cEEG included amplitude-integrated EEG trends and two channels with original EEG-signals. Basic EEG background patterns and presence of epileptiform discharges or seizure activity were assessed on 5-grade rank-ordered scales based on standardized EEG terminology. An EEG-expert was used as reference. RESULTS: There was substantial agreement (κ 0.69) for EEG background patterns and moderate agreement (κ 0.43) for epileptiform discharges between ICU physicians and the EEG-expert. Sensitivity for detecting seizure activity by ICU physicians was limited (50%), but with high specificity (87%). CONCLUSIONS: After cardiac arrest, preliminary bedside interpretations of simplified cEEGs by trained ICU physicians may allow earlier detection of clinically relevant cEEG changes, prompting changes in patient management as well as additional evaluation by an EEG-expert. This strategy requires awareness of limitations of both the simplified electrode montage and the cEEG interpretations performed by ICU physicians. cEEG evaluation by an expert should not be delayed.
Assuntos
Cuidados Críticos/métodos , Eletroencefalografia/métodos , Parada Cardíaca/complicações , Monitorização Fisiológica/métodos , Sistemas Automatizados de Assistência Junto ao Leito , Convulsões/diagnóstico , Idoso , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Monitorização Fisiológica/instrumentação , Reprodutibilidade dos Testes , Convulsões/etiologia , Sensibilidade e EspecificidadeRESUMO
The mechanical deformation of the wound edge resulting from negative pressure wound therapy (NPWT) at the standard setting of around -120 mmHg has positive effects in promoting wound healing. However, it may cause pain to the patient during treatment. It is therefore important to study the mechanical effects of the wound edges using lower pressure and different wound fillers. Abdominal wounds were created on eight pigs. The wounds were sealed for NPWT using foam or gauze. Negative pressures between -20 and -160 mmHg were applied, and the decrease in wound diameter and the force with which the edges of the wound were drawn together (wound edge force) were measured. Increasing levels of negative pressure resulted in a gradual decrease in wound diameter and increase in wound edge force and reached a maximum at -120 mmHg, which is the pressure commonly used in clinical practice. Both the decrease in wound diameter and the increase in wound edge force was greater with foam than with gauze. A pressure of -80 mmHg has only 15% less effect than -120 mmHg, while a lower pressure (-40 mmHg) diminished the effects on diameter and force markedly. The NPWT-induced decrease in wound diameter and increase in wound edge force are greater at higher levels of negative pressure and when using foam than when using gauze as a wound filler. It may be possible to tailor the type of wound filler and level of negative pressure to obtain the best balance between wound healing and patient comfort.
Assuntos
Traumatismos Abdominais/terapia , Tratamento de Ferimentos com Pressão Negativa/métodos , Cicatrização/fisiologia , Ferimentos e Lesões/terapia , Animais , Bandagens , Modelos Animais de Doenças , Fenômenos MecânicosRESUMO
OBJECTIVES: Dysglycemia and glycemic variability are associated with poor outcomes in critically ill patients. Targeted temperature management alters blood glucose homeostasis. We investigated the association between blood glucose concentrations and glycemic variability and the neurologic outcomes of patients randomized to targeted temperature management at 33°C or 36°C after cardiac arrest. DESIGN: Post hoc analysis of the multicenter TTM-trial. Primary outcome of this analysis was neurologic outcome after 6 months, referred to as "Cerebral Performance Category." SETTING: Thirty-six sites in Europe and Australia. PATIENTS: All 939 patients with out-of-hospital cardiac arrest of presumed cardiac cause that had been included in the TTM-trial. INTERVENTIONS: Targeted temperature management at 33°C or 36°C. MEASUREMENTS AND MAIN RESULTS: Nonparametric tests as well as multiple logistic regression and mixed effects logistic regression models were used. Median glucose concentrations on hospital admission differed significantly between Cerebral Performance Category outcomes (p < 0.0001). Hyper- and hypoglycemia were associated with poor neurologic outcome (p = 0.001 and p = 0.054). In the multiple logistic regression models, the median glycemic level was an independent predictor of poor Cerebral Performance Category (Cerebral Performance Category, 3-5) with an odds ratio (OR) of 1.13 in the adjusted model (p = 0.008; 95% CI, 1.03-1.24). It was also a predictor in the mixed model, which served as a sensitivity analysis to adjust for the multiple time points. The proportion of hyperglycemia was higher in the 33°C group compared with the 36°C group. CONCLUSION: Higher blood glucose levels at admission and during the first 36 hours, and higher glycemic variability, were associated with poor neurologic outcome and death. More patients in the 33°C treatment arm had hyperglycemia.
Assuntos
Glicemia/fisiologia , Temperatura Corporal , Reanimação Cardiopulmonar/métodos , Hipotermia Induzida/métodos , Parada Cardíaca Extra-Hospitalar/mortalidade , Parada Cardíaca Extra-Hospitalar/fisiopatologia , Parada Cardíaca Extra-Hospitalar/terapia , Feminino , Escala de Resultado de Glasgow , Humanos , Hiperglicemia/fisiopatologia , Hipoglicemia/fisiopatologia , Masculino , Fatores de TempoRESUMO
BACKGROUND: It is well-known that infectious complications after central venous catheterisation are associated with increased mortality, length of hospital stay and costs. However, there are limited data regarding such associations for immediate insertion-related complications. Therefore, the aim of this study was to investigate whether major immediate insertion-related complications are associated with mortality, length of hospital stay and costs. METHODS: This was a preplanned substudy to the CVC-MECH trial on immediate insertion-related complications after central venous catheterisation in the ultrasound-guided era. Patients receiving central venous catheters at Skåne University Hospital from 2 March 2019 to 31 December 2020 were prospectively included. Patient characteristics, clinical data and costs were automatically collected from medical journals and the patient administration system. Associations between major immediate insertion-related complications and mortality, length of hospital stay and costs were studied by multivariable logistic and linear regression analyses. RESULTS: In total, 6671 patients were included, of whom 0.5% suffered major immediate insertion-related complications. Multivariable analyses, including surrogates for general morbidity, showed associations between major immediate insertion-related complications and 30-day (odds ratio 2.46 [95% CI 1.05-5.77]), 90-day (2.90 [1.35-6.21]) and 180-day (2.26 [1.05-4.83]) mortality. There were no associations between major immediate insertion-related complications and increased length of hospital stay or costs. CONCLUSION: This study showed that major immediate insertion-related complications, although not directly responsible for any death, were associated with increased 30-day, 90-day and 180-day mortality. These findings clearly demonstrate the importance of using all possible means to prevent avoidable insertion-related complications after central venous catheterisation.
RESUMO
BACKGROUND: There are increasing reports of serious complications and deaths associated with negative pressure wound therapy (NPWT). Bleeding may occur when NPWT is applied to a wound with exposed blood vessels. Inserting a rigid disc in the wound may protect these structures. The authors examined the effects of rigid discs on wound bed tissue pressure and blood flow through a large blood vessel in the wound bed during NPWT. METHODS: Wounds were created over the femoral artery in the groin of 8 pigs. Rigid discs were inserted. Wound bed pressures and arterial blood flow were measured during NPWT. RESULTS: Pressure transduction to the wound bed was similar for control wounds and wounds with discs. Blood flow through the femoral artery decreased in control wounds. When a disc was inserted, the blood flow was restored. CONCLUSIONS: NPWT causes hypoperfusion in the wound bed tissue, presumably as a result of mechanical deformation. The insertion of a rigid barrier alleviates this effect and restores blood flow.
Assuntos
Tratamento de Ferimentos com Pressão Negativa/instrumentação , Fluxo Sanguíneo Regional/fisiologia , Cicatrização/fisiologia , Análise de Variância , Animais , Feminino , Artéria Femoral/fisiologia , Membro Posterior/irrigação sanguínea , Membro Posterior/lesões , Membro Posterior/cirurgia , Masculino , Tratamento de Ferimentos com Pressão Negativa/métodos , Pressão , SuínosRESUMO
INTRODUCTION: Central venous catheters are indispensable in modern healthcare. Unfortunately, they are accompanied by minor as well as major complications, leading to increased morbidity, mortality and costs. Immediate insertion-related complications (mechanical complications) have decreased due to the implementation of real-time ultrasound guidance, but they still occur and additional efforts to enhance patient safety are warranted. This study aims to investigate whether the use of a needle guide mounted on the ultrasound probe in subclavian catheterisations may decrease the number of catheterisations with >1 skin puncture (primary outcome). METHODS AND ANALYSIS: This is an investigator-initiated, non-commercial, randomised, controlled, parallel-group study conducted at Skåne University Hospital, Lund, Sweden. Adults (≥18 years) with a clinical indication for a subclavian central venous catheter and the ability to give written informed consent will be eligible for inclusion. Exclusion criteria include subclavian catheterisation deemed unsuitable based on the preprocedural ultrasound examination. Patients will be randomised to catheterisation by certified operators using a microconvex probe (long-axis, in-plane technique) with (n=150) or without (n=150) a needle guide. The ultrasound imaging from the procedures will be recorded and assessed by two reviewers individually. The assessors will be blinded for group affiliation. Secondary outcomes include the total number of skin punctures, mechanical complications, time to successful venous puncture, number of failed catheterisations and operator satisfaction with the needle guide at the end of the study period.Recruitment started on 8 November 2022 and will continue until the sample size is achieved. ETHICS AND DISSEMINATION: This study was approved by the Swedish Ethical Review Authority (#2022-04073-01) and the Swedish Medical Products Agency (#5.1-2022-52130; CIV-21-12-038367). The findings will be submitted to an international peer-reviewed journal. TRIAL REGISTRATION NUMBER: NCT05513378, clinicaltrials.gov.
Assuntos
Cateterismo Venoso Central , Cateteres Venosos Centrais , Adulto , Humanos , Cateterismo Venoso Central/métodos , Veia Subclávia/diagnóstico por imagem , Ultrassonografia , Ultrassonografia de Intervenção/métodos , Ensaios Clínicos Controlados Aleatórios como AssuntoRESUMO
BACKGROUND: This study investigated the association of two levels of targeted temperature management (TTM) after out-of-hospital cardiac arrest (OHCA) with administered doses of sedative and analgesic drugs, serum concentrations, and the effect on time to awakening. METHODS: This substudy of the TTM2-trial was conducted at three centers in Sweden, with patients randomized to either hypothermia or normothermia. Deep sedation was mandatory during the 40-hour intervention. Blood samples were collected at the end of TTM and end of protocolized fever prevention (72 hours). Samples were analysed for concentrations of propofol, midazolam, clonidine, dexmedetomidine, morphine, oxycodone, ketamine and esketamine. Cumulative doses of administered sedative and analgesic drugs were recorded. RESULTS: Seventy-one patients were alive at 40 hours and had received the TTM-intervention according to protocol. 33 patients were treated at hypothermia and 38 at normothermia. There were no differences between cumulative doses and concentration and of sedatives/analgesics between the intervention groups at any timepoint. Time until awakening was 53 hours in the hypothermia group compared to 46 hours in the normothermia group (p = 0.09). CONCLUSION: This study of OHCA patients treated at normothermia versus hypothermia found no significant differences in dosing or concentration of sedatives or analgesic drugs in blood samples drawn at the end of the TTM intervention, or at end of protocolized fever prevention, nor the time to awakening.
Assuntos
Hipotermia Induzida , Hipotermia , Parada Cardíaca Extra-Hospitalar , Humanos , Hipnóticos e Sedativos/uso terapêutico , Parada Cardíaca Extra-Hospitalar/terapia , Hipotermia/terapia , Hipotermia Induzida/métodos , AnalgésicosRESUMO
BACKGROUND: The right internal jugular vein is currently recommended for temporary central dialysis catheters (tCDC) based on results from previous studies showing a lower incidence of central vein stenosis compared to the subclavian vein. Data is however conflicting, and there are several advantages when the subclavian route is used for tCDCs. This prospective, controlled, randomised, non-inferiority study aims to compare the incidence of post-catheterisation central vein stenosis between the right subclavian and the right internal jugular routes. METHODS: Adult patients needing a tCDC will be included from several hospitals and randomised to either subclavian or internal jugular vein catheterisation with a silicone tCDC. Inclusion continues until 50 patients in each group have undergone a follow-up CT venography. The primary outcome is the incidence of post-catheterisation central vein stenosis detected by a CT venography performed 1.5 to 3 months after removal of the tCDC. Secondary outcomes include between-group comparisons of (I) the patients' experience of discomfort and pain, (II) any dysfunction of the tCDC during use, (III) catheterisation success rate and (IV) the number of mechanical complications. Furthermore, the ability to detect central vein stenosis by a focused ultrasound examination will be evaluated using the CT venography as golden standard. DISCUSSION: The use of the subclavian route for tCDC placement has largely been abandoned due to older studies with various methodological issues. However, the subclavian route offers several advantages for the patient. This trial is designed to provide robust data on the incidence of central vein stenosis after silicone tCDC insertion in the era of ultrasound-guided catheterisations. TRIAL REGISTRATION: Clinicaltrials.gov; NCT04871568. Prospectively registered on May 4, 2021.
Assuntos
Cateterismo Venoso Central , Doenças Vasculares , Adulto , Humanos , Cateterismo Venoso Central/efeitos adversos , Cateterismo Venoso Central/métodos , Catéteres , Constrição Patológica , Veias Jugulares/diagnóstico por imagem , Estudos Prospectivos , Diálise Renal/efeitos adversos , Ensaios Clínicos Controlados Aleatórios como AssuntoRESUMO
There are increasing reports of deaths and serious complications associated with the use of negative pressure wound therapy (NPWT). Bleeding may occur in patients when NPWT is applied to a wound with exposed blood vessels or vascular grafts, possibly due to mechanical deformation and hypoperfusion of the vessel walls. Recent evidence suggests that using a rigid barrier disc to protect underlying tissue can prevent this mechanical deformation. The aim of this study was to examine the effect of rigid discs on the tissue exposed to negative pressure with regard to tissue pressure and microvascular blood flow. Peripheral wounds were created on the backs of eight pigs. The pressure and microvascular blood flow in the wound bed were measured when NPWT was applied. The wound was filled with foam, and rigid discs of different designs were inserted between the wound bed and the foam. The discs were created with or without channels (to accommodate exposed sensitive structures such as blood vessels and nerves), perforations, or a porous dressing that covered the underside of the discs (to facilitate pressure transduction and fluid evacuation). When comparing the results for pressure transduction to the wound bed, no significant differences were found using different discs covered with dressing, whereas pressure transduction was lower with bare discs. Microvascular blood flow in the wound bed decreased by 49 ± 7% when NPWT was applied to control wounds. The reduction in blood flow was less in the presence of a protective disc (e.g., -6 ± 5% for a dressing-covered, perforated disc, p = 0.006). In conclusion, NPWT causes hypoperfusion of superficial tissue in the wound bed. The insertion of a rigid barrier counteracts this effect. The placement of a rigid disc over exposed blood vessels or nerves may protect these structures from rupture and damage.
Assuntos
Implantes Experimentais , Tratamento de Ferimentos com Pressão Negativa/efeitos adversos , Cicatrização , Ferimentos e Lesões/terapia , Animais , Bandagens , Modelos Animais de Doenças , Feminino , Hemodinâmica , Masculino , Desenho de Prótese , Suínos , Resultado do Tratamento , Ferimentos e Lesões/fisiopatologiaRESUMO
BACKGROUND: Central venous catheter (CVC) misplacement occurs frequently after right subclavian vein catheterization. It can be avoided by using ultrasound to confirm correct guidewire tip position in the lower superior vena cava prior to CVC insertion. However, retraction of the guidewire during the CVC insertion may dislocate the guidewire tip from its desired and confirmed position, thereby resulting in CVC misplacement. The aim of this study was to determine the minimal guidewire length required to maintain correct guidewire tip position in the lower superior vena cava throughout an ultrasound-guided CVC placement in the right subclavian vein. METHODS: One hundred adult patients with a computed tomography scan of the chest were included. By using multiplanar reconstructions from thin-sliced images, the distance from the most plausible distal puncture site of the right subclavian vein to the optimal guidewire tip position in the lower superior vena cava was measured (vessel length). In addition, measurements of equipment in common commercial over-the-wire percutaneous 15-16 cm CVC kits were performed. The 95th percentile of the vessel length was used to calculate the required minimal guidewire length for each CVC kit. RESULTS: The 95th percentile of the vessel length was 153 mm. When compared to the calculated minimal guidewire length, the guidewires were up to 108 mm too short in eight of eleven CVC kits. CONCLUSION: After confirmation of a correct guidewire position, retraction of the guidewire tip above the junction of the brachiocephalic veins should be avoided prior to CVC insertion in order to preclude dislocation of the catheter tip towards the right internal jugular vein or the left subclavian vein. This study shows that many commercial over-the-wire percutaneous 15-16 cm CVC kits contain guidewires that are too short for right subclavian vein catheterization, i.e., guidewire retraction is needed prior to CVC insertion.
Assuntos
Cateterismo Venoso Central , Cateteres Venosos Centrais , Adulto , Humanos , Veias Jugulares , Veia Subclávia/diagnóstico por imagem , Tomografia Computadorizada por Raios X , Veia Cava Superior/diagnóstico por imagemRESUMO
Background: Several biochemical markers in blood correlate with the magnitude of brain injury and may be used to predict neurological outcome after cardiac arrest. We present a protocol for the evaluation of prognostic accuracy of brain injury markers after cardiac arrest. The aim is to define the best predictive marker and to establish clinically useful cut-off levels for routine implementation. Methods: Prospective international multicenter trial within the Targeted Hypothermia versus Targeted Normothermia after Out-of-Hospital Cardiac Arrest (TTM2) trial in collaboration with Roche Diagnostics International AG. Samples were collected 0, 24, 48, and 72 hours after randomisation (serum) and 0 and 48 hours after randomisation (plasma), and pre-analytically processed at each site before storage in a central biobank. Routine markers neuron-specific enolase (NSE) and S100B, and neurofilament light, total-tau and glial fibrillary acidic protein will be batch analysed using novel Elecsys® electrochemiluminescence immunoassays on a Cobas e601 instrument. Results: Statistical analysis will be reported according to the Standards for Reporting Diagnostic accuracy studies (STARD) and will include comparisons for prediction of good versus poor functional outcome at six months post-arrest, by modified Rankin Scale (0-3 vs. 4-6), using logistic regression models and receiver operating characteristics curves, evaluation of mortality at six months according to biomarker levels and establishment of cut-off values for prediction of poor neurological outcome at 95-100% specificities. Conclusions: This prospective trial may establish a standard methodology and clinically appropriate cut-off levels for the optimal biomarker of brain injury which predicts poor neurological outcome after cardiac arrest.
RESUMO
The effects of negative pressure wound therapy (NPWT) on wound edge microvascular blood flow are not clear. The aim of the present study was therefore to further elucidate the effects of NPWT on periwound blood flow in a porcine peripheral wound model using different blood flow measurement techniques. NPWT at -20, -40, -80, and -125 mmHg was applied to a peripheral porcine wound (n = 8). Thermodiffusion, transcutaneous, and invasive laser Doppler velocimetry were used to measure the blood perfusion 0.5, 1.0, and 2.5 cm from the wound edge. Thermodiffusion (an invasive measurement technique) generally showed a decrease in perfusion close to the wound edge (0.5 cm), and an increase further from the edge (2.5 cm). Invasive laser Doppler velocimetry showed a similar response pattern, with a decrease in blood flow 0.5 cm from the wound edge and an increase further away. However, 1.0 cm from the wound edge blood flow decreased with high pressure levels and increased with low pressure levels. A different response pattern was seen with transcutaneous laser Doppler velocimetry, showing an increase in blood flow regardless of the distance from the wound edge (0.5, 1.0, and 2.5 cm). During NPWT, both increases and decreases in blood flow can be seen in the periwound tissue depending on the distance from the wound edge and the pressure level. The pattern of response depends partly on the measurement technique used. The combination of hypoperfusion and hyperperfusion caused by NPWT may accelerate wound healing.