Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 252
Filtrar
Mais filtros

Base de dados
Tipo de documento
Intervalo de ano de publicação
1.
Artigo em Inglês | MEDLINE | ID: mdl-38978150

RESUMO

BACKGROUND: The new building of the Hospital in Lichtenfels (Germany) was put into operation in mid-July 2018. Neither the medical personnel nor medical departments have been changed. We want to evaluate how "safe" or "insecure" the new hospital or department in the beginning might have been. Our objective is to investigate if safety decreases at the beginning in a new hospital, despite modern environments and conditions. METHODS: Adverse events associated with treatment were included to evaluate the total number of adverse events resulting from medical care and medications. Patients records had to be closed and completed, the length of stay had to be at least 24 hours, the patient had to have been formally admitted to the hospital (Institute for Healthcare Improvement IHI GTT "Global Trigger Tool" recommendation). The identified adverse events were grouped into 27 categories of the Institute for Healthcare Improvement "Global Trigger Tool." We randomly reviewed 40 patient records per month 6 months before and 6 months after moving to the new hospital. RESULTS: Statistical analysis showed that there was no significant difference in individual adverse events. The sum of adverse events was statistically higher after moving into a new hospital. Complete number of harms did reach statistical significance (χ2=6.62; df=1; p<.05; Cramer's V=0.12), indicating that new environments "triggers" significantly more potential errors (50%) in comparison to the old environments (38.33%). CONCLUSION: According to our results, the new hospital is slightly insecure in the first period (6 months) after its founding.

2.
Am Heart J ; 265: 66-76, 2023 11.
Artigo em Inglês | MEDLINE | ID: mdl-37422010

RESUMO

BACKGROUND: Atrial fibrillation (AF) is one of the most frequent causes of stroke. Several randomized trials have shown that prolonged monitoring increases the detection of AF, but the effect on reducing recurrent cardioembolism, ie, ischemic stroke and systemic embolism, remains unknown. We aim to evaluate whether a risk-adapted, intensified heart rhythm monitoring with consequent guideline conform treatment, which implies initiation of oral anticoagulation (OAC), leads to a reduction of recurrent cardioembolism. METHODS: Find-AF 2 is a randomized, controlled, open-label parallel multicenter trial with blinded endpoint assessment. 5,200 patients ≥ 60 years of age with symptomatic ischemic stroke within the last 30 days and without known AF will be included at 52 study centers with a specialized stroke unit in Germany. Patients without AF in an additional 24-hour Holter ECG after the qualifying event will be randomized in a 1:1 fashion to either enhanced, prolonged and intensified ECG-monitoring (intervention arm) or standard of care monitoring (control arm). In the intervention arm, patients with a high risk of underlying AF will receive continuous rhythm monitoring using an implantable cardiac monitor (ICM) whereas those without high risk of underlying AF will receive repeated 7-day Holter ECGs. The duration of rhythm monitoring within the control arm is up to the discretion of the participating centers and is allowed for up to 7 days. Patients will be followed for at least 24 months. The primary efficacy endpoint is the time until recurrent ischemic stroke or systemic embolism occur. CONCLUSIONS: The Find-AF 2 trial aims to demonstrate that enhanced, prolonged and intensified rhythm monitoring results in a more effective prevention of recurrent ischemic stroke and systemic embolism compared to usual care.


Assuntos
Fibrilação Atrial , Embolia , AVC Isquêmico , Acidente Vascular Cerebral , Humanos , Lactente , Fibrilação Atrial/complicações , Fibrilação Atrial/diagnóstico , Furilfuramida , Estudos Prospectivos , Acidente Vascular Cerebral/etiologia , Acidente Vascular Cerebral/prevenção & controle , Acidente Vascular Cerebral/diagnóstico , Eletrocardiografia Ambulatorial/métodos , Embolia/diagnóstico , Embolia/etiologia , Embolia/prevenção & controle
3.
J Membr Biol ; 255(1): 13-31, 2022 02.
Artigo em Inglês | MEDLINE | ID: mdl-34383081

RESUMO

We have experimented with isolated cardiomyocytes of mollusks Helix. During the whole-cell patch-clamp recordings of K+ currents a considerable decrease in amplitude was observed upon repeated voltage steps at 0.96 Hz. For these experiments, ventricular cells were depolarized to identical + 20 mV from a holding potential of - 50 mV. The observed spontaneous inhibition of outward currents persisted in the presence of 4-aminopyridine, tetraethylammonium chloride or E-4031, the selective class III antiarrhythmic agent that blocks HERG channels. Similar tendency was retained when components of currents sensitive to either 4-AP or TEA were mathematically subtracted. Waveforms of currents sensitive to 1 and 10 micromolar concentration of E-4031 were distinct comprising prevailingly those activated during up to 200 ms pulses. The outward current activated by a voltage ramp at 60 mV x s-1 rate revealed an inward rectification around + 20 mV. This feature closely resembles those of the mammalian cardiac delayed rectifier IKr.


Assuntos
4-Aminopiridina , Canais de Potássio , 4-Aminopiridina/farmacologia , Animais , Técnicas In Vitro , Mamíferos , Potenciais da Membrana , Técnicas de Patch-Clamp , Tetraetilamônio/farmacologia
4.
J Cardiovasc Electrophysiol ; 33(3): 483-492, 2022 03.
Artigo em Inglês | MEDLINE | ID: mdl-35028995

RESUMO

BACKGROUND: Registry data add important information to randomized controlled trials (RCT) on real-life aspects of implantable cardioverter-defibrillator (ICD) patients with and without cardiac resynchronization therapy (CRT-D). This analysis of the prospectively conducted German Device Registry aims at comparing mortality rates, comorbidities, complication rates to results from RCT. METHODS: The German Device registry (DEVICE) prospectively collected data on ICD and CRT-D first implantations from 50 German centres. Demographic data, details on cardiac disease, electrocardiogram (ECG), medication, and data about procedure, complications, and hospital stay were stored in electronic case report forms. One year after device implantation patients were contacted for follow-up. RESULTS: DEVICE included n = 4384 first ICD/CRT-D implantations (29.3% CRT-D devices). We found a strong adherence to guidelines with over 90% of patients being on ß-blocker and ACE-inhibitor medication and adequate QRS width in the majority of CRT-D patients. Patients receiving a CRT-D were older (67.6 ± 11.0 years vs. 63.9 ± 13.4 years, p < .001) and had lower ejection fractions (mean 25% vs. 30%, p < .001) compared to ICD patients. Dilated cardiomyopathy was the predominant underlying heart disease in CRT-D (53.3%), coronary artery disease in ICD patients (64.7%). Compared to RCT our DEVICE patients had more comorbidities (17.9% chronic kidney disease [CKD]) and higher 1-year mortality rates (10.7% ICD group, 12.3% CRT group). In multivariate analysis, CKD patients had an almost 2-fold higher risk of 1-year mortality. CONCLUSION: Despite relevant limitations of registry data, DEVICE highlights important differences between RCT and real-world registry data and the impact of comorbidities on mortality of ICD and CRT-D recipients.


Assuntos
Terapia de Ressincronização Cardíaca , Desfibriladores Implantáveis , Insuficiência Cardíaca , Terapia de Ressincronização Cardíaca/efeitos adversos , Terapia de Ressincronização Cardíaca/métodos , Dispositivos de Terapia de Ressincronização Cardíaca , Desfibriladores Implantáveis/efeitos adversos , Insuficiência Cardíaca/diagnóstico , Insuficiência Cardíaca/etiologia , Insuficiência Cardíaca/terapia , Humanos , Ensaios Clínicos Controlados Aleatórios como Assunto , Sistema de Registros , Resultado do Tratamento
5.
Catheter Cardiovasc Interv ; 99(7): 2064-2070, 2022 06.
Artigo em Inglês | MEDLINE | ID: mdl-35384249

RESUMO

BACKGROUND: Interventional left atrial appendage occlusion (LAAO) is routinely performed in patients with nonvalvular atrial fibrillation and contraindications to standard anticoagulation. AIMS: We investigated its role in patients at low stroke risk, and compared the effectiveness and safety in patients with low versus high risk. METHODS: LAARGE is a prospective registry depicting the clinical reality of LAAO. LAAO was conducted with different standard commercial devices, and follow-up period was 1 year. Patients with started procedure and documented CHA2 DS2 -VASc score were selected from the whole database. RESULTS: A total of 638 patients from 38 centers were divided into CHA2 DS2 -VASc score ≤2, i.e., low-risk group (10.2%), and >2, i.e., high-risk group (89.8%). The latter had a pronounced cardiovascular risk profile and preceding strokes (0% vs. 23.9%; p < 0.001). Implantation success was consistently high (97.6%), frequencies of intrahospital major adverse cardiac and cerebrovascular events (0% vs. 0.5%) and other major complications (4.6% vs. 4.0%) were low (each p = not significant [NS]). Numerous moderate complications were also observed in the low-risk patients (12.3% vs. 9.4%; p = NS). Frequencies of nonfatal strokes (0% vs. 0.7%) and severe bleedings (0% vs. 0.7%) were low (each p = NS). In a specific analysis, patients at very high risk of stroke (i.e., CHA2 DS2 -VASc score >4) did not have increased rates of complications or nonfatal strokes in the first year after the procedure. CONCLUSIONS: Low-risk patients had no nonfatal strokes and major bleedings within 1 year after hospital discharge but had unexpectedly high rates of moderate procedural complications. The indication in these patients should be strictly defined based on an individual benefit-risk assessment.


Assuntos
Apêndice Atrial , Fibrilação Atrial , Acidente Vascular Cerebral , Apêndice Atrial/diagnóstico por imagem , Fibrilação Atrial/complicações , Fibrilação Atrial/diagnóstico , Fibrilação Atrial/terapia , Hemorragia , Humanos , Sistema de Registros , Acidente Vascular Cerebral/diagnóstico , Acidente Vascular Cerebral/etiologia , Acidente Vascular Cerebral/prevenção & controle , Resultado do Tratamento
6.
JAMA ; 327(23): 2296-2305, 2022 06 21.
Artigo em Inglês | MEDLINE | ID: mdl-35727277

RESUMO

Importance: Ablation of persistent atrial fibrillation (AF) remains a challenge. Left atrial fibrosis plays an important role in the pathophysiology of AF and has been associated with poor procedural outcomes. Objective: To investigate the efficacy and adverse events of targeting atrial fibrosis detected on magnetic resonance imaging (MRI) in reducing atrial arrhythmia recurrence in persistent AF. Design, Setting, and Participants: The Efficacy of Delayed Enhancement-MRI-Guided Fibrosis Ablation vs Conventional Catheter Ablation of Atrial Fibrillation trial was an investigator-initiated, multicenter, randomized clinical trial involving 44 academic and nonacademic centers in 10 countries. A total of 843 patients with symptomatic or asymptomatic persistent AF and undergoing AF ablation were enrolled from July 2016 to January 2020, with follow-up through February 19, 2021. Interventions: Patients with persistent AF were randomly assigned to pulmonary vein isolation (PVI) plus MRI-guided atrial fibrosis ablation (421 patients) or PVI alone (422 patients). Delayed-enhancement MRI was performed in both groups before the ablation procedure to assess baseline atrial fibrosis and at 3 months postablation to assess for ablation scar. Main Outcomes and Measures: The primary end point was time to first atrial arrhythmia recurrence after a 90-day blanking period postablation. The primary safety composite outcome was defined by the occurrence of 1 or more of the following events within 30 days postablation: stroke, PV stenosis, bleeding, heart failure, or death. Results: Among 843 patients who were randomized (mean age 62.7 years; 178 [21.1%] women), 815 (96.9%) completed the 90-day blanking period and contributed to the efficacy analyses. There was no significant difference in atrial arrhythmia recurrence between groups (fibrosis-guided ablation plus PVI patients, 175 [43.0%] vs PVI-only patients, 188 [46.1%]; hazard ratio [HR], 0.95 [95% CI, 0.77-1.17]; P = .63). Patients in the fibrosis-guided ablation plus PVI group experienced a higher rate of safety outcomes (9 [2.2%] vs 0 in PVI group; P = .001). Six patients (1.5%) in the fibrosis-guided ablation plus PVI group had an ischemic stroke compared with none in PVI-only group. Two deaths occurred in the fibrosis-guided ablation plus PVI group, and the first one was possibly related to the procedure. Conclusions and Relevance: Among patients with persistent AF, MRI-guided fibrosis ablation plus PVI, compared with PVI catheter ablation only, resulted in no significant difference in atrial arrhythmia recurrence. Findings do not support the use of MRI-guided fibrosis ablation for the treatment of persistent AF. Trial Registration: ClinicalTrials.gov Identifier: NCT02529319.


Assuntos
Técnicas de Ablação , Fibrilação Atrial , Fibrose , Átrios do Coração , Imageamento por Ressonância Magnética , Cirurgia Assistida por Computador , Técnicas de Ablação/efeitos adversos , Técnicas de Ablação/métodos , Fibrilação Atrial/complicações , Fibrilação Atrial/diagnóstico por imagem , Fibrilação Atrial/cirurgia , Ablação por Cateter/efeitos adversos , Ablação por Cateter/métodos , Feminino , Fibrose/diagnóstico por imagem , Fibrose/cirurgia , Átrios do Coração/patologia , Átrios do Coração/cirurgia , Humanos , Masculino , Pessoa de Meia-Idade , Veias Pulmonares/diagnóstico por imagem , Veias Pulmonares/cirurgia , Recidiva , Cirurgia Assistida por Computador/efeitos adversos , Cirurgia Assistida por Computador/métodos , Resultado do Tratamento
7.
Stroke ; 52(8): 2715-2722, 2021 08.
Artigo em Inglês | MEDLINE | ID: mdl-34192898

RESUMO

Occult atrial fibrillation (AF) is a leading cause of stroke of unclear cause. The optimal approach to secondary stroke prevention for these patients remains elusive. The term embolic stroke of undetermined source (ESUS) was coined to describe ischemic strokes in which the radiographic features demonstrate territorial infarcts resembling those seen in patients with confirmed sources of embolism but without a clear source of embolism detected. It was assumed that patients with ESUS had a high rate of occult AF and would benefit from treatment with direct oral anticoagulants, which are at least as effective as vitamin K antagonists for secondary stroke prevention in patients with AF, but with a much lower risk of intracerebral hemorrhage. Two recent large randomized trials failed to show superiority of direct oral anticoagulants over aspirin in ESUS patients. These findings prompt a reexamination of the ESUS concept, with the goal of improving specificity for detecting patients with a cardioembolic cause. Based on the negative trial results, there is renewed interest in the role of long-term cardiac monitoring for AF in patients who fit the current ESUS definition, as well as the clinical implication of detecting AF. Ongoing trials are exploring these questions. Current ESUS definitions do not accurately detect the patients who should be prescribed direct oral anticoagulants, potentially because occult AF is less common than expected in these patients and/or anticoagulants may be less beneficial in patients with ESUS but no AF than they are for patients with stroke with established AF. More specific criteria to identify patients who may be at higher risk for occult AF and reduce their risk of subsequent stroke have been developed and are being tested in ongoing clinical trials.


Assuntos
Terapia Antiplaquetária Dupla/métodos , AVC Embólico/tratamento farmacológico , AVC Embólico/etiologia , Prevenção Secundária/métodos , Anticoagulantes/administração & dosagem , Aspirina/administração & dosagem , Fibrilação Atrial/sangue , Fibrilação Atrial/complicações , Fibrilação Atrial/tratamento farmacológico , Hemorragia Cerebral/sangue , Hemorragia Cerebral/complicações , Hemorragia Cerebral/tratamento farmacológico , Ensaios Clínicos como Assunto/métodos , AVC Embólico/sangue , Inibidores do Fator Xa/administração & dosagem , Humanos , Embolia Intracraniana/sangue , Embolia Intracraniana/complicações , Embolia Intracraniana/tratamento farmacológico , Rivaroxabana/administração & dosagem
8.
N Engl J Med ; 378(5): 417-427, 2018 Feb 01.
Artigo em Inglês | MEDLINE | ID: mdl-29385358

RESUMO

BACKGROUND: Mortality and morbidity are higher among patients with atrial fibrillation and heart failure than among those with heart failure alone. Catheter ablation for atrial fibrillation has been proposed as a means of improving outcomes among patients with heart failure who are otherwise receiving appropriate treatment. METHODS: We randomly assigned patients with symptomatic paroxysmal or persistent atrial fibrillation who did not have a response to antiarrhythmic drugs, had unacceptable side effects, or were unwilling to take these drugs to undergo either catheter ablation (179 patients) or medical therapy (rate or rhythm control) (184 patients) for atrial fibrillation in addition to guidelines-based therapy for heart failure. All the patients had New York Heart Association class II, III, or IV heart failure, a left ventricular ejection fraction of 35% or less, and an implanted defibrillator. The primary end point was a composite of death from any cause or hospitalization for worsening heart failure. RESULTS: After a median follow-up of 37.8 months, the primary composite end point occurred in significantly fewer patients in the ablation group than in the medical-therapy group (51 patients [28.5%] vs. 82 patients [44.6%]; hazard ratio, 0.62; 95% confidence interval [CI], 0.43 to 0.87; P=0.007). Significantly fewer patients in the ablation group died from any cause (24 [13.4%] vs. 46 [25.0%]; hazard ratio, 0.53; 95% CI, 0.32 to 0.86; P=0.01), were hospitalized for worsening heart failure (37 [20.7%] vs. 66 [35.9%]; hazard ratio, 0.56; 95% CI, 0.37 to 0.83; P=0.004), or died from cardiovascular causes (20 [11.2%] vs. 41 [22.3%]; hazard ratio, 0.49; 95% CI, 0.29 to 0.84; P=0.009). CONCLUSIONS: Catheter ablation for atrial fibrillation in patients with heart failure was associated with a significantly lower rate of a composite end point of death from any cause or hospitalization for worsening heart failure than was medical therapy. (Funded by Biotronik; CASTLE-AF ClinicalTrials.gov number, NCT00643188 .).


Assuntos
Fibrilação Atrial/tratamento farmacológico , Fibrilação Atrial/cirurgia , Ablação por Cateter , Insuficiência Cardíaca/complicações , Idoso , Antiarrítmicos/uso terapêutico , Fibrilação Atrial/complicações , Fibrilação Atrial/mortalidade , Ablação por Cateter/efeitos adversos , Feminino , Seguimentos , Insuficiência Cardíaca/mortalidade , Insuficiência Cardíaca/fisiopatologia , Frequência Cardíaca/efeitos dos fármacos , Hospitalização/estatística & dados numéricos , Humanos , Estimativa de Kaplan-Meier , Masculino , Pessoa de Meia-Idade , Função Ventricular Esquerda , Teste de Caminhada
9.
Eur Respir J ; 57(2)2021 02.
Artigo em Inglês | MEDLINE | ID: mdl-32859673

RESUMO

INTRODUCTION: Early discharge of patients with acute low-risk pulmonary embolism requires validation by prospective trials with clinical and quality-of-life outcomes. METHODS: The multinational Home Treatment of Patients with Low-Risk Pulmonary Embolism with the Oral Factor Xa Inhibitor Rivaroxaban (HoT-PE) single-arm management trial investigated early discharge followed by ambulatory treatment with rivaroxaban. The study was stopped for efficacy after the positive results of the predefined interim analysis at 50% of the planned population. The present analysis includes the entire trial population (576 patients). In addition to 3-month recurrence (primary outcome) and 1-year overall mortality, we analysed self-reported disease-specific (Pulmonary Embolism Quality of Life (PEmb-QoL) questionnaire) and generic (five-level five-dimension EuroQoL (EQ-5D-5L) scale) quality of life as well as treatment satisfaction (Anti-Clot Treatment Scale (ACTS)) after pulmonary embolism. RESULTS: The primary efficacy outcome occurred in three (0.5%, one-sided upper 95% CI 1.3%) patients. The 1-year mortality was 2.4%. The mean±sd PEmb-QoL decreased from 28.9±20.6% at 3 weeks to 19.9±15.4% at 3 months, a mean change (improvement) of -9.1% (p<0.0001). Improvement was consistent across all PEmb-QoL dimensions. The EQ-5D-5L was 0.89±0.12 at 3 weeks after enrolment and improved to 0.91±0.12 at 3 months (p<0.0001). Female sex and cardiopulmonary disease were associated with poorer disease-specific and generic quality of life; older age was associated with faster worsening of generic quality of life. The ACTS burden score improved from 40.5±6.6 points at 3 weeks to 42.5±5.9 points at 3 months (p<0.0001). CONCLUSIONS: Our results further support early discharge and ambulatory oral anticoagulation for selected patients with low-risk pulmonary embolism. Targeted strategies may be necessary to further improve quality of life in specific patient subgroups.


Assuntos
Embolia Pulmonar , Qualidade de Vida , Idoso , Feminino , Humanos , Alta do Paciente , Estudos Prospectivos , Embolia Pulmonar/tratamento farmacológico , Inquéritos e Questionários
10.
J Cardiovasc Electrophysiol ; 32(10): 2636-2644, 2021 10.
Artigo em Inglês | MEDLINE | ID: mdl-34314065

RESUMO

INTRODUCTION: Gender-based differences in atrial fibrillation have been identified, but limited data exist for patients undergoing left atrial appendage occluder (LAAO) implantation. This study reports gender-related periprocedural and 1-year outcomes of the prospective, multicenter German left atrial appendage occlusion registry (LAARGE). METHODS: LAARGE enrolled 641 patients who were scheduled for LAAO implantation from July 2014 to January 2016 in 38 hospitals in Germany. The data collected included demographics, clinical characteristics, details of implantation, and outcome. Efficacy and safety at 1-year follow-up were assessed by the occurrence of thrombembolic and bleeding events, as well as mortality. RESULTS: Of 638 patients undergoing LAAO implantation 38.9% were female and 61.1% male. Females were older (76.4 ± 8.2 [females] vs. 75.6 ± 7.7 [males], p = .042) and had a higher stroke risk (CHA2 DS2 -VASc score: 4.9 ± 1.5 vs. 4.3 ± 1.5, p < .001). In contrast, males suffered more often from coronary artery (33.1% vs. 53.8%, p < .001) and vascular disease (18.5% vs. 31.0%, p < .001). Technical success was high and similar for both genders (98.4% vs. 97.2%, p = .33). Severe periprocedural complications (6.9% vs. 3.1%, p = .032) occurred more often in females. At 1-year follow-up the rates of all-cause stroke (0.5% vs. 1.3%, p = .65) and severe bleeding (0.0% and 1.0%, p = .29) were low and comparable between the genders. Also, one-year all-cause mortality (9.2% vs. 13.1%, p = .14) did not differ significantly. CONCLUSION: LAARGE documented in this elderly patient population undergoing LAAO implantation a higher rate of severe periprocedural complications in females. At 1-year follow-up similar efficacy and safety outcomes were observed for both genders.


Assuntos
Apêndice Atrial , Fibrilação Atrial , Dispositivo para Oclusão Septal , Acidente Vascular Cerebral , Idoso , Apêndice Atrial/diagnóstico por imagem , Apêndice Atrial/cirurgia , Fibrilação Atrial/diagnóstico , Fibrilação Atrial/cirurgia , Feminino , Humanos , Masculino , Estudos Prospectivos , Sistema de Registros , Acidente Vascular Cerebral/etiologia , Acidente Vascular Cerebral/prevenção & controle , Resultado do Tratamento
11.
J Cardiovasc Electrophysiol ; 32(7): 1833-1841, 2021 07.
Artigo em Inglês | MEDLINE | ID: mdl-33955108

RESUMO

BACKGROUND: The impact of basic atrial rhythm (sinus rhythm [SR] vs. atrial fibrillation [AF]) during AF ablation on efficacy and safety is unknown. METHODS: About 3375 patients from the German Ablation Registry undergoing first-time AF ablation were divided according to the type of AF and the basic atrial rhythm during the ablation procedure: paroxysmal AF (PAF) and SR [group Ia], PAF and AF [group Ib]), persistent AF and SR (IIa), and persistent AF and AF (IIb). RESULTS: Patients in SR (n = 2312 [67%]) underwent cryoballoon ablation more often (Ia vs. Ib p = .002 and IIa vs. IIb p = .010, whereas in patients in AF (n = 1063 [33%]) radiofrequency (RF)-based ablation (Ia vs. Ib p = .006 and IIa vs. IIb p = .014) including left and/or right atrial substrate modification was more frequently performed. Depending on the basic rhythm there was no difference regarding arrhythmia recurrence during long-term follow-up. For patients suffering from persistent AF acute procedure-related complications were more often documented when ablated in AF (9.1% vs. 4.6%, p = .012). which was mainly driven by the higher occurrence of pericardial effusion/tamponade. For patients suffering from persistent AF, favorable results were found regarding 366-day Kaplan-Meier estimates of the incidence of MACCE (death, myocardial infarction, and stroke; p = .011) and the composite endpoint of death, myocardial infarction, stroke, and major bleeding (p = .006), when ablated in SR. CONCLUSION: Basic atrial rhythm at the time of AF ablation did not affect long-term rhythm outcome. For patients suffering from persistent AF a more favorable acute and long-term safety profile was observed when ablated in SR.


Assuntos
Fibrilação Atrial , Ablação por Cateter , Fibrilação Atrial/diagnóstico , Fibrilação Atrial/cirurgia , Ablação por Cateter/efeitos adversos , Átrios do Coração , Humanos , Recidiva , Sistema de Registros , Resultado do Tratamento
12.
J Cardiovasc Electrophysiol ; 32(4): 916-924, 2021 04.
Artigo em Inglês | MEDLINE | ID: mdl-33600025

RESUMO

INTRODUCTION: Success rates of catheter ablation in persistent atrial fibrillation (AF) remain suboptimal. A better and more targeted ablation strategy is urgently needed to optimize outcomes of AF treatment. We sought to assess the safety and efficacy of targeting atrial fibrosis during ablation of persistent AF patients in improving procedural outcomes. METHODS: The DECAAF II trial (ClinicalTrials. gov identifier number NCT02529319) is a prospective, randomized, multicenter trial of patients with persistent AF. Patients with persistent AF undergoing a first-time ablation procedure were randomized in a 1:1 fashion to receive conventional pulmonary vein isolation (PVI) ablation (Group 1) or PVI + fibrosis-guided ablation (Group 2). Left atrial fibrosis and ablation induced scarring were defined by late gadolinium enhancement magnetic resonance imaging at baseline and at 3-12 months postablation, respectively. The primary endpoint is the recurrence of atrial arrhythmia postablation, including atrial fibrillation, atrial flutter, or atrial tachycardia after the 90-day postablation blanking period. Patients were followed for a period of 12-18 months with a smartphone ECG Device (ECG Check Device, Cardiac Designs Inc.). With an anticipated enrollment of 900 patients, this study has an 80% power to detect a 26% reduction in the hazard ratio of the primary endpoint. RESULTS AND CONCLUSION: The DECAAF II trial is the first prospective, randomized, multicenter trial of patients with persistent AF using imaging defined atrial fibrosis as a treatment target. The trial will help define an optimal approach to catheter ablation of persistent AF, further our understanding of influencers of ablation lesion formation, and refine selection criteria for ablation based on atrial myopathy burden.


Assuntos
Fibrilação Atrial , Ablação por Cateter , Veias Pulmonares , Fibrilação Atrial/diagnóstico por imagem , Fibrilação Atrial/cirurgia , Ablação por Cateter/efeitos adversos , Meios de Contraste , Fibrose , Gadolínio , Humanos , Imageamento por Ressonância Magnética , Estudos Prospectivos , Veias Pulmonares/cirurgia , Recidiva , Resultado do Tratamento
13.
Eur Heart J ; 41(4): 509-518, 2020 01 21.
Artigo em Inglês | MEDLINE | ID: mdl-31120118

RESUMO

AIMS: To investigate the efficacy and safety of early transition from hospital to ambulatory treatment in low-risk acute PE, using the oral factor Xa inhibitor rivaroxaban. METHODS AND RESULTS: We conducted a prospective multicentre single-arm investigator initiated and academically sponsored management trial in patients with acute low-risk PE (EudraCT Identifier 2013-001657-28). Eligibility criteria included absence of (i) haemodynamic instability, (ii) right ventricular dysfunction or intracardiac thrombi, and (iii) serious comorbidities. Up to two nights of hospital stay were permitted. Rivaroxaban was given at the approved dose for PE for ≥3 months. The primary outcome was symptomatic recurrent venous thromboembolism (VTE) or PE-related death within 3 months of enrolment. An interim analysis was planned after the first 525 patients, with prespecified early termination of the study if the null hypothesis could be rejected at the level of α = 0.004 (<6 primary outcome events). From May 2014 through June 2018, consecutive patients were enrolled in seven countries. Of the 525 patients included in the interim analysis, three (0.6%; one-sided upper 99.6% confidence interval 2.1%) suffered symptomatic non-fatal VTE recurrence, a number sufficiently low to fulfil the condition for early termination of the trial. Major bleeding occurred in 6 (1.2%) of the 519 patients comprising the safety population. There were two cancer-related deaths (0.4%). CONCLUSION: Early discharge and home treatment with rivaroxaban is effective and safe in carefully selected patients with acute low-risk PE. The results of the present trial support the selection of appropriate patients for ambulatory treatment of PE.


Assuntos
Pacientes Ambulatoriais , Alta do Paciente/tendências , Embolia Pulmonar/tratamento farmacológico , Rivaroxabana/administração & dosagem , Adolescente , Adulto , Idoso , Idoso de 80 Anos ou mais , Esquema de Medicação , Inibidores do Fator Xa/administração & dosagem , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Estudos Prospectivos , Recidiva , Fatores de Risco , Resultado do Tratamento , Adulto Jovem
14.
Circulation ; 140(13): 1061-1069, 2019 09 24.
Artigo em Inglês | MEDLINE | ID: mdl-31466479

RESUMO

BACKGROUND: Atrial arrhythmias are common in patients with implantable cardioverter-defibrillator (ICD). External shocks and internal cardioversion through commanded ICD shock for electrical cardioversion are used for rhythm-control. However, there is a paucity of data on efficacy of external versus internal cardioversion and on the risk of lead and device malfunction. We hypothesized that external cardioversion is noninferior to internal cardioversion for safety, and superior for successful restoration of sinus rhythm. METHODS: Consecutive patients with ICD undergoing elective cardioversion for atrial arrhythmias at 13 centers were randomized in 1:1 fashion to either internal or external cardioversion. The primary safety end point was a composite of surrogate events of lead or device malfunction. Conversion of atrial arrhythmia to sinus rhythm was the primary efficacy end point. Myocardial damage was studied by measuring troponin release in both groups. RESULTS: N=230 patients were randomized. Shock efficacy was 93% in the external cardioversion group and 65% in the internal cardioversion group (P<0.001). Clinically relevant adverse events caused by external or internal cardioversion were not observed. Three cases of pre-existing silent lead malfunction were unmasked by internal shock, resulting in lead failure. Troponin release did not differ between groups. CONCLUSIONS: This is the first randomized trial on external vs internal cardioversion in patients with ICDs. External cardioversion was superior for the restoration of sinus rhythm. The unmasking of silent lead malfunction in the internal cardioversion group suggests that an internal shock attempt may be reasonable in selected ICD patients presenting for electrical cardioversion. CLINICAL TRIAL REGISTRATION: URL: https://www.clinicaltrials.gov. Unique identifier: NCT03247738.


Assuntos
Arritmias Cardíacas/terapia , Fibrilação Atrial/terapia , Desfibriladores Implantáveis , Cardioversão Elétrica/métodos , Idoso , Idoso de 80 Anos ou mais , Falha de Equipamento , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Risco
15.
Circulation ; 140(22): 1834-1850, 2019 11 26.
Artigo em Inglês | MEDLINE | ID: mdl-31765261

RESUMO

Cardiac thromboembolism attributed to atrial fibrillation (AF) is responsible for up to one-third of ischemic strokes. Stroke may be the first manifestation of previously undetected AF. Given the efficacy of oral anticoagulants in preventing AF-related ischemic strokes, strategies of searching for AF after a stroke using ECG monitoring followed by oral anticoagulation (OAC) treatment have been proposed to prevent recurrent cardioembolic strokes. This white paper by experts from the AF-SCREEN International Collaboration summarizes existing evidence and knowledge gaps on searching for AF after a stroke by using ECG monitoring. New AF can be detected by routine plus intensive ECG monitoring in approximately one-quarter of patients with ischemic stroke. It may be causal, a bystander, or neurogenically induced by the stroke. AF after a stroke is a risk factor for thromboembolism and a strong marker for atrial myopathy. After acute ischemic stroke, patients should undergo 72 hours of electrocardiographic monitoring to detect AF. The diagnosis requires an ECG of sufficient quality for confirmation by a health professional with ECG rhythm expertise. AF detection rate is a function of monitoring duration and quality of analysis, AF episode definition, interval from stroke to monitoring commencement, and patient characteristics including old age, certain ECG alterations, and stroke type. Markers of atrial myopathy (eg, imaging, atrial ectopy, natriuretic peptides) may increase AF yield from monitoring and could be used to guide patient selection for more intensive/prolonged poststroke ECG monitoring. Atrial myopathy without detected AF is not currently sufficient to initiate OAC. The concept of embolic stroke of unknown source is not proven to identify patients who have had a stroke benefitting from empiric OAC treatment. However, some embolic stroke of unknown source subgroups (eg, advanced age, atrial enlargement) might benefit more from non-vitamin K-dependent OAC therapy than aspirin. Fulfilling embolic stroke of unknown source criteria is an indication neither for empiric non-vitamin K-dependent OAC treatment nor for withholding prolonged ECG monitoring for AF. Clinically diagnosed AF after a stroke or a transient ischemic attack is associated with significantly increased risk of recurrent stroke or systemic embolism, in particular, with additional stroke risk factors, and requires OAC rather than antiplatelet therapy. The minimum subclinical AF duration required on ECG monitoring poststroke/transient ischemic attack to recommend OAC therapy is debated.


Assuntos
Fibrilação Atrial , Isquemia Encefálica , Eletrocardiografia , Acidente Vascular Cerebral , Tromboembolia , Idoso , Fibrilação Atrial/diagnóstico , Fibrilação Atrial/etiologia , Fibrilação Atrial/fisiopatologia , Isquemia Encefálica/complicações , Isquemia Encefálica/diagnóstico , Isquemia Encefálica/fisiopatologia , Feminino , Humanos , Masculino , Acidente Vascular Cerebral/complicações , Acidente Vascular Cerebral/diagnóstico , Acidente Vascular Cerebral/fisiopatologia , Tromboembolia/diagnóstico , Tromboembolia/fisiopatologia
16.
J Cardiovasc Electrophysiol ; 31(4): 934-942, 2020 04.
Artigo em Inglês | MEDLINE | ID: mdl-32072692

RESUMO

INTRODUCTION: The LAmbre (LifeTech Scientific, Shenzhen, China) is a novel occluder for left atrial appendage closure (LAAC) in patients with atrial fibrillation. This study compares late clinical outcomes of LAmbre and the established Amplatzer devices (Abbott, St Paul, MN). METHODS: Between 2012 and 2018, 265 consecutive patients underwent LAAC with LAmbre and Amplatzer devices at a single center. After a 3:1 propensity score matching, 40 (LAmbre) vs 107 (Amplatzer) patients were compared by the primary efficacy endpoint of all-cause stroke, systemic embolism and cardiovascular/unexplained death, the primary safety endpoint of major periprocedural complications and major bleeding events at follow-up, and the combined hazard endpoint, a composite of all the above-mentioned hazards. RESULTS: The mean age 75.6 ± 8.9 (LAmbre) vs 75.5 ± 9.0 (Amplatzer) years, CHA2 DS2 -VASc score 4.8 ± 1.7 vs 4.8 ± 1.7 and HAS-BLED score 3.1 ± 0.9 vs 3.2 ± 0.8 were similar. After 3.6 ± 1.9 vs 2.5 ± 1.4 years, the clinical efficacy (12/146, 8.2% [LAmbre] vs 28/266, 10.5% [Amplatzer]; hazard ratio [HR], 0.73; 95% confidence interval [CI], 0.38-1.40; P = .34) and safety (5/146, 3.4% vs 14/266, 5.3%; HR, 0.47; 95% CI, 0.14-1.6; P = .22), as well as the combined hazard endpoint (15/146, 10.3% vs 36/266, 13.6%; HR, 0.67; 95% CI, 0.36-1.25; P = .21) were comparable. CONCLUSION: In the presented report, in patients with nonvalvular atrial fibrillation, the LAmbre offered similar long-term efficacy and safety in comparison to Amplatzer devices.


Assuntos
Apêndice Atrial , Fibrilação Atrial/terapia , Cateterismo Cardíaco/instrumentação , Dispositivo para Oclusão Septal , Acidente Vascular Cerebral/prevenção & controle , Potenciais de Ação , Idoso , Idoso de 80 Anos ou mais , Apêndice Atrial/fisiopatologia , Fibrilação Atrial/diagnóstico , Fibrilação Atrial/mortalidade , Fibrilação Atrial/fisiopatologia , Função do Átrio Esquerdo , Cateterismo Cardíaco/efeitos adversos , Cateterismo Cardíaco/mortalidade , Feminino , Frequência Cardíaca , Humanos , Masculino , Desenho de Prótese , Sistema de Registros , Estudos Retrospectivos , Medição de Risco , Fatores de Risco , Acidente Vascular Cerebral/diagnóstico , Acidente Vascular Cerebral/mortalidade , Fatores de Tempo , Resultado do Tratamento
17.
Catheter Cardiovasc Interv ; 96(3): E324-E331, 2020 09 01.
Artigo em Inglês | MEDLINE | ID: mdl-31631493

RESUMO

OBJECTIVES: To compare long-term clinical outcomes after left atrial appendage closure with the Amplatzer Cardiac Plug (ACP) and Amulet. BACKGROUND: The Amulet was designed to improve clinical outcomes of first-generation ACP. METHODS: Three Amplatzer registries (Bern, Coburg, Zurich), with enrollment of patients from 2009 to 2018, were retrospectively analyzed. The primary safety endpoint was a composite of major peri-procedural complications and major bleedings, the primary efficacy endpoint included stroke, systemic embolism, and cardiovascular/unexplained death. The net clinical benefit was a combination of all above-mentioned hazards. RESULTS: A total of consecutive 563 patients (344 ACP vs. 219 Amulet) with a mean follow-up of 2.9 ± 1.6 and 1.9 ± 0.9 years were included. Mean age (74.4 ± 9.9 [ACP] vs. 74.4 ± 9.1 [Amulet] years), stroke (CHA2 DS2 -VASc score 4.4 ± 1.6 vs. 4.6 ± 1.7), and bleeding risk (HAS-BLED score 3.2 ± 1.1 vs. 3.2 ± 0.9) were comparable. The primary endpoints of efficacy (72/998, 7.2% [ACP] vs. 43/417, 10.3% [Amulet]; hazard ratio [HR], 0.67; 95% confidence interval [CI], 0.44-1.02, p = .062), safety (40/998, 4.0% vs. 18/417, 4.3%; HR, 1.15; 95% CI, 0.53-2.51, p = .72), and the net clinical benefit (101/998, 10.1% vs. 55/417, 13.4%; HR, 0.73; 95% CI, 0.49-1.07, p = .11) were similar. CONCLUSION: In the long term, left atrial appendage closure with first and second-generation Amplatzer devices provided similar efficacy, safety, and net clinical benefit. Clinical outcomes may be rather determined by implantation technique and hemodynamics, but not by the design modifications of the Amulet.


Assuntos
Apêndice Atrial/fisiopatologia , Fibrilação Atrial/terapia , Cateterismo Cardíaco/instrumentação , Dispositivo para Oclusão Septal , Acidente Vascular Cerebral/prevenção & controle , Idoso , Idoso de 80 Anos ou mais , Fibrilação Atrial/diagnóstico , Fibrilação Atrial/mortalidade , Fibrilação Atrial/fisiopatologia , Função do Átrio Esquerdo , Cateterismo Cardíaco/efeitos adversos , Feminino , Alemanha , Frequência Cardíaca , Humanos , Masculino , Desenho de Prótese , Sistema de Registros , Estudos Retrospectivos , Acidente Vascular Cerebral/diagnóstico , Acidente Vascular Cerebral/mortalidade , Suíça , Fatores de Tempo , Resultado do Tratamento
18.
Europace ; 22(6): 897-905, 2020 06 01.
Artigo em Inglês | MEDLINE | ID: mdl-32243508

RESUMO

AIMS: Persistent atrial fibrillation (AF) has been explained by multiple mechanisms which, while they conflict, all agree that more disorganized AF is more difficult to treat than organized AF. We hypothesized that persistent AF consists of interacting organized areas which may enlarge, shrink or coalesce, and that patients whose AF areas enlarge by ablation are more likely to respond to therapy. METHODS AND RESULTS: We mapped vectorial propagation in persistent AF using wavefront fields (WFF), constructed from raw unipolar electrograms at 64-pole basket catheters, during ablation until termination (Group 1, N = 20 patients) or cardioversion (Group 2, N = 20 patients). Wavefront field mapping of patients (age 61.1 ± 13.2 years, left atrium 47.1 ± 6.9 mm) at baseline showed 4.6 ± 1.0 organized areas, each separated by disorganization. Ablation of sites that led to termination controlled larger organized area than competing sites (44.1 ± 11.1% vs. 22.4 ± 7.0%, P < 0.001). In Group 1, ablation progressively enlarged unablated areas (rising from 32.2 ± 15.7% to 44.1 ± 11.1% of mapped atrium, P < 0.0001). In Group 2, organized areas did not enlarge but contracted during ablation (23.6 ± 6.3% to 15.2 ± 5.6%, P < 0.0001). CONCLUSION: Mapping wavefront vectors in persistent AF revealed competing organized areas. Ablation that progressively enlarged remaining areas was acutely successful, and sites where ablation terminated AF were surrounded by large organized areas. Patients in whom large organized areas did not emerge during ablation did not exhibit AF termination. Further studies should define how fibrillatory activity is organized within such areas and whether this approach can guide ablation.


Assuntos
Fibrilação Atrial , Ablação por Cateter , Idoso , Fibrilação Atrial/diagnóstico , Fibrilação Atrial/cirurgia , Cardioversão Elétrica , Átrios do Coração/cirurgia , Humanos , Pessoa de Meia-Idade
19.
Pacing Clin Electrophysiol ; 43(11): 1242-1251, 2020 11.
Artigo em Inglês | MEDLINE | ID: mdl-32779203

RESUMO

BACKGROUND: Optimal antithrombotic therapy following left atrial appendage closure (LAAC) with the Watchman occluder remains uncertain. This study retrospectively compared clinical outcomes of a 3-month dual antiplatelet therapy (DAPT group) and a protocol of anticoagulation plus aspirin for 45 days followed by DAPT for 6 months (ACT group) after LAAC with the Watchman device. METHODS: Of two Watchman registries (Coburg and Lichtenfels hospitals, Germany), 220 and 304 consecutive patients with successful LAAC were included. Patients in Coburg hospital received DAPT while they received ACT in Lichtenfels. After a 1:1 propensity score matching, 174 (DAPT) versus 174 (ACT) patients were compared by use of the primary efficacy endpoint of thromboembolic events and cardiovascular/unexplained death, the primary safety endpoint of nonprocedural related major bleeding events at follow-up, and the combined hazard endpoint, a composite of all above-mentioned hazards. RESULTS: The mean age 77.5 ± 7.2 (DAPT) versus 77.3 ± 7.1 (ACT) years, CHA2 DS2 -VASc score 4.6 ± 1.5 versus 4.7 ± 1.6, and HAS-BLED score 3.3 ± 0.8 versus 3.3 ± 0.8 were similar. After 12 months, the clinical efficacy (13/174, 7.4% [DAPT] vs 11/174, 6.3% [ACT]; hazard ratio [HR], 0.84; 95% confidence interval [CI], 0.38-1.86; P = .66) and safety (6/174, 3.4% vs 8/174, 4.5%; HR, 0.86; 95% CI, 0.29-2.56; P = .79) as well as the combined hazard endpoint (18/174, 10.3% vs 18/174, 10.3%; HR,1.01; 95% CI, 0.53-1.95; P = .97) were comparable. CONCLUSIONS: This study suggests comparable efficacy and safety of 3-month DAPT versus 6 weeks ACT plus aspirin following LAAC with the Watchman.


Assuntos
Anticoagulantes/uso terapêutico , Apêndice Atrial/cirurgia , Inibidores da Agregação Plaquetária/uso terapêutico , Dispositivo para Oclusão Septal , Idoso , Idoso de 80 Anos ou mais , Ecocardiografia Transesofagiana , Feminino , Alemanha , Humanos , Masculino , Pessoa de Meia-Idade , Pontuação de Propensão , Sistema de Registros
20.
J Membr Biol ; 252(6): 609-616, 2019 12.
Artigo em Inglês | MEDLINE | ID: mdl-31584122

RESUMO

Effects of ibutilide, a class III antiarrhythmic drug, on delayed rectifier potassium currents (IK) in freshly isolated guinea pig ventricular myocytes were studied. Experiments were performed using the whole-cell configuration of patch-clamp technique under blockade of L-type calcium currents (Cav1). Ibutilide at concentrations ranging between 10 nM and 100 µM inhibited IKr in dose-dependent manner with a half maximal effective concentration of 2.03 ± 0.74 µM (n = 5-10). The amplitude of tail currents activated by prepulse to + 20 mV was decreased from 253 ± 52 to 130 ± 25 pA (n = 8, p < 0.01) in the presence of 1 µM ibutilide. The envelope test revealed time-dependent changes in ratio of IK-tail/ΔIK during 0.2-2 s pulse durations in the absence of drug. With ibutilide, regardless of pulse duration, a relatively constant ratio was estimated, indicative of predominant involvement of IKr component. The slow IKs persisted to greater extent even at 100 µM ibutilide revealing a distinguishable selectivity toward the IKr component.


Assuntos
Canais de Potássio/efeitos dos fármacos , Sulfonamidas/farmacologia , Animais , Cálcio/metabolismo , Canais de Cálcio Tipo L/efeitos dos fármacos , Canais de Cálcio Tipo L/metabolismo , Células Cultivadas , Cobaias , Ventrículos do Coração/citologia , Miócitos Cardíacos/efeitos dos fármacos , Miócitos Cardíacos/metabolismo , Potássio/metabolismo
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA