Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 47
Filtrar
Mais filtros

Base de dados
País/Região como assunto
Tipo de documento
Intervalo de ano de publicação
1.
J Clin Microbiol ; 56(10)2018 10.
Artigo em Inglês | MEDLINE | ID: mdl-30068537

RESUMO

High accuracy and precision at the lower end of quantification are crucial requirements of a modern HIV viral load (VL) assay, since some clinically relevant thresholds are located at 50 and 200 copies/ml. In this study, we compared the performance of two new fully automated HIV-1 VL assays, Aptima HIV-1 Quant Dx and Cobas HIV-1 (Cobas 6800), with the established RealTime m2000 assay. Assay precision and accuracy were evaluated in a retrospective evaluation out of excess plasma material from four HIV-1+ individuals (subtypes B, C, CRF01_AE, and CRF02_AG). Native plasma samples were diluted to nominal concentrations at 50 and 200 copies/ml (according to the RealTime m2000 assay). All dilutions were tested in triplicate in five independent runs over 5 days and in three labs per system. Assay concordance was determined using 1,011 surplus clinical routine samples, as well as selected retrospective longitudinal samples from 7 patients on treatment. The three assays yielded highly concordant results for individual clinical samples (R2 > 0.98; average difference, ≤0.2 log copies/ml) and retrospective longitudinal samples from patients on treatment. The Aptima and RealTime assays showed similar high precision, meeting the 5σ criterion for the majority of samples across all labs and subtypes. The Cobas assay was less precise, missing the 5σ criterion for the majority of samples at low concentrations. In this analysis, results from the Cobas assay appeared less reliable near the clinically relevant cutoff and should be interpreted with more caution in this context. Due to high precision, full automation, and high concordance with the RealTime assay, the Aptima assay represents a good alternative in routine VL monitoring.


Assuntos
Infecções por HIV/virologia , HIV-1/isolamento & purificação , Técnicas de Diagnóstico Molecular/normas , Carga Viral/métodos , Automação Laboratorial , HIV-1/genética , Humanos , RNA Viral/sangue , RNA Viral/genética , Kit de Reagentes para Diagnóstico , Estudos Retrospectivos , Sensibilidade e Especificidade
2.
J Clin Microbiol ; 55(7): 2055-2063, 2017 07.
Artigo em Inglês | MEDLINE | ID: mdl-28424254

RESUMO

The analytical performance of the Veris HIV-1 assay for use on the new, fully automated Beckman Coulter DxN Veris molecular diagnostics system was evaluated at 10 European virology laboratories. The precision, analytical sensitivity, performance with negative samples, linearity, and performance with HIV-1 groups/subtypes were evaluated. The precision for the 1-ml assay showed a standard deviation (SD) of 0.14 log10 copies/ml or less and a coefficient of variation (CV) of ≤6.1% for each level tested. The 0.175-ml assay showed an SD of 0.17 log10 copies/ml or less and a CV of ≤5.2% for each level tested. The analytical sensitivities determined by probit analysis were 19.3 copies/ml for the 1-ml assay and 126 copies/ml for the 0.175-ml assay. The performance with 1,357 negative samples demonstrated 99.2% with not detected results. Linearity using patient samples was shown from 1.54 to 6.93 log10 copies/ml. The assay performed well, detecting and showing linearity with all HIV-1 genotypes tested. The Veris HIV-1 assay demonstrated analytical performance comparable to that of currently marketed HIV-1 assays. (DxN Veris products are Conformité Européenne [CE]-marked in vitro diagnostic products. The DxN Veris product line has not been submitted to the U.S. FDA and is not available in the U.S. market. The DxN Veris molecular diagnostics system is also known as the Veris MDx molecular diagnostics system and the Veris MDx system.).


Assuntos
Automação Laboratorial/métodos , Infecções por HIV/diagnóstico , HIV-1/isolamento & purificação , Técnicas de Diagnóstico Molecular/métodos , Europa (Continente) , Humanos , Sensibilidade e Especificidade
3.
J Clin Microbiol ; 55(4): 1186-1192, 2017 04.
Artigo em Inglês | MEDLINE | ID: mdl-28151405

RESUMO

The analytical performance of the Veris HCV Assay for use on the new and fully automated Beckman Coulter DxN Veris Molecular Diagnostics System (DxN Veris System) was evaluated at 10 European virology laboratories. Precision, analytical sensitivity, specificity, and performance with negative samples, linearity, and performance with hepatitis C virus (HCV) genotypes were evaluated. Precision for all sites showed a standard deviation (SD) of 0.22 log10 IU/ml or lower for each level tested. Analytical sensitivity determined by probit analysis was between 6.2 and 9.0 IU/ml. Specificity on 94 unique patient samples was 100%, and performance with 1,089 negative samples demonstrated 100% not-detected results. Linearity using patient samples was shown from 1.34 to 6.94 log10 IU/ml. The assay demonstrated linearity upon dilution with all HCV genotypes. The Veris HCV Assay demonstrated an analytical performance comparable to that of currently marketed HCV assays when tested across multiple European sites.


Assuntos
Automação Laboratorial/métodos , Hepacivirus/isolamento & purificação , Hepatite C Crônica/virologia , Reação em Cadeia da Polimerase em Tempo Real/métodos , Carga Viral/métodos , Europa (Continente) , Humanos , Sensibilidade e Especificidade
4.
J Emerg Med ; 50(4): 594-600.e1, 2016 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-26607696

RESUMO

BACKGROUND: Chest compression quality is decisive for overall outcome after cardiac arrest. Chest compression depth may decrease when cardiopulmonary resuscitation (CPR) is performed on a mattress, and the use of a backboard does not necessarily improve compression depth. Mechanical chest compression devices may overcome this problem. OBJECTIVES: We sought to investigate the effectiveness of manual chest compressions both with and without a backboard compared to mechanical CPR performed on surfaces of different softness. METHODS: Twenty-four advanced life support (ALS)-certified rescuers were enrolled. LUCAS2 (Physio-Control, Redmond, WA) delivers 52 ± 2 mm deep chest compressions and active decompressions back to the neutral position (frequency 102 min(-1); duty cycle, 50%). This simulated CPR scenario was performed on a Resusci-Anne manikin (Laerdal, Stavanger, Norway) that was lying on 3 different surfaces: 1) a concrete floor, 2) a firm standard mattress, and 3) a pressure-relieving mattress. Data were recorded by the Laerdal Skill Reporting System. RESULTS: Manual chest compression with or without a backboard were performed correctly less often than mechanical chest compressions (floor: 33% [interquartile range {IQR}, 27-48%] vs. 90% [IQR, 86-94%], p < 0.001; standard mattress: 32% [IQR, 20-45%] vs. 27% [IQR, 14-46%] vs. 91% [IQR, 51-94%], p < 0.001; and pressure-relieving mattress 29% [IQR, 17-49%] vs. 30% [IQR, 17-52%] vs. 91% [IQR, 87-95%], p < 0.001). The mean compression depth on both mattresses was deeper with mechanical chest compressions (floor: 53 mm [range, 47-57 mm] vs. 56 mm [range, 54-57 mm], p = 0.003; standard mattress: 50 mm [range, 44-55 mm] vs. 51 mm [range, 47-55 mm] vs. 55 mm [range, 54-58 mm], p < 0.001; and pressure-relieving mattress: 49 mm [range, 44-55 mm] vs. 50 mm [range, 44-53 mm] vs. 55 mm [range, 55-56 mm], p < 0.001). In this ∼6-min scenario, the mean hands-off time was ∼15 to 20 s shorter in the manual CPR scenarios. CONCLUSIONS: In this experimental study, only ∼30% of manual chest compressions were performed correctly compared to ∼90% of mechanical chest compressions, regardless of the underlying surface. Backboard use did not influence the mean compression depth during manual CPR. Chest compressions were deeper with mechanical CPR. The mean hands-off time was shorter with manual CPR.


Assuntos
Massagem Cardíaca/métodos , Manequins , Leitos , Estudos Cross-Over , Desenho de Equipamento , Massagem Cardíaca/instrumentação , Pressão
5.
J Emerg Med ; 48(1): 103-7, 2015 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-25308899

RESUMO

BACKGROUND: In preoxygenated patients, time until oxygen saturation drops can be extended by insufflating oxygen into their airways, thus oxygenating them apneically. OBJECTIVES: To compare different methods of apneic oxygenation. METHODS: A noncommercial dual-use laryngoscope with an internal lumen in its blade was used to provide oxygen insufflation into a simulated laryngeal space during intubation. In this experimental study, oxygen insufflation via the dual-use laryngoscope was compared with no oxygen insufflation, with nasal oxygen insufflation, and with direct intratracheal oxygen insufflation. In a preoxygenated test lung of a manikin, oxygen percentage decrease was measured over a 20-min observation period for each method of oxygen application. RESULTS: Oxygen percentage in the test lung dropped from 97% to 37 ± 1% in the control group (p < 0.001 compared to all other groups) and to 68 ± 1% in the nasal insufflation group (p < 0.001 compared to all other groups). Oxygen percentage remained over 90% in both the direct intratracheal insufflation group (96 ± 0%) and the laryngoscope blade insufflation group (94 ± 1%) (p < 0.01 between the latter two groups). CONCLUSIONS: Simulating apneic oxygenation in a preoxygenated manikin, deep laryngeal oxygen insufflation via the dual-use laryngoscope kept oxygen percentage in the test lung above 90%, and was more effective than oxygen insufflation via nasal prongs.


Assuntos
Apneia/terapia , Insuflação/instrumentação , Intubação Intratraqueal/instrumentação , Laringoscópios , Oxigênio/administração & dosagem , Humanos , Insuflação/métodos , Intubação Intratraqueal/métodos , Pulmão/metabolismo , Manequins , Oxigênio/farmacocinética
6.
Med Microbiol Immunol ; 202(1): 67-75, 2013 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-22699843

RESUMO

The goal of antiretroviral therapy is reduction in morbidity and mortality via suppression of human immunodeficiency virus (HIV) viral load (VL) to undetectable levels. VL assay sensitivity has improved over time, but the reproducibility and clinical importance of VL results marginally higher than the limit of detection (LoD) are uncertain. We assessed the reproducibility and concordance of low VL results obtained with the Roche Cobas AmpliPrep/Cobas TaqMan HIV-1 version 2.0 (CAP-CTM) and the Abbott RealTime (m2000) HIV-1 assays, using longitudinal specimens from HIV-1-infected patients with low VL (<300 copies/ml) and stable CD4+ cell counts. Based on replicate testing of 3 specimens, coefficients of variation for log-transformed VL results were 5-8 % for m2000 and 9-10 % for CAP-CTM. The concordance between assays in specimens from patients with previously undetectable, detectable but not quantifiable VL, or variable (undetectable/detectable but not quantifiable VL) results over time was 90, 56, and 56 %, respectively. Correlation between results for specimens with quantifiable VL (initially 40-300 copies/ml) was moderate (R (2) = 0.48) with significantly higher results for CAP-CTM and a mean difference (CAP-CTM minus m2000) of 0.10 log(10) copies/ml. T-cell activation (CD8+/CD38+ percentage) in patients with low VL was initially higher than in patients with undetectable VL, and then decreased to equivalent levels over time. These results indicate that residual viremia at levels slightly above the LoD have no negative effect on T-cell activation.


Assuntos
Infecções por HIV/virologia , HIV-1/isolamento & purificação , Carga Viral/métodos , Viremia/virologia , Infecções por HIV/imunologia , HIV-1/imunologia , Humanos , Ativação Linfocitária , Reprodutibilidade dos Testes , Linfócitos T/imunologia , Viremia/imunologia
7.
Am J Emerg Med ; 31(2): 384-9, 2013 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-23000324

RESUMO

OBJECTIVE: High-quality chest-compressions are of paramount importance for survival and good neurological outcome after cardiac arrest. However, even healthcare professionals have difficulty performing effective chest-compressions, and quality may be further reduced during transport. We compared a mechanical chest-compression device (Lund University Cardiac Assist System [LUCAS]; Jolife, Lund, Sweden) and manual chest-compressions in a simulated cardiopulmonary resuscitation scenario during helicopter rescue. METHODS: Twenty-five advanced life support-certified paramedics were enrolled for this prospective, randomized, crossover study. A modified Resusci Anne manikin was employed. Thirty minutes of training was allotted to both LUCAS and manual cardiopulmonary resuscitation (CPR). Thereafter, every candidate performed the same scenario twice, once with LUCAS and once with manual CPR. The primary outcome measure was the percentage of correct chest-compressions relative to total chest-compressions. RESULTS: LUCAS compared to manual chest-compressions were more frequently correct (99% vs 59%, P < .001) and were more often performed correctly regarding depth (99% vs 79%, P < .001), pressure point (100% vs 79%, P < .001) and pressure release (100% vs 97%, P = .001). Hands-off time was shorter in the LUCAS than in the manual group (46 vs 130 seconds, P < .001). Time until first defibrillation was longer in the LUCAS group (112 vs 49 seconds, P < .001). CONCLUSIONS: During this simulated cardiac arrest scenario in helicopter rescue LUCAS compared to manual chest-compressions increased CPR quality and reduced hands-off time, but prolonged the time interval to the first defibrillation. Further clinical trials are warranted to confirm potential benefits of LUCAS CPR in helicopter rescue.


Assuntos
Resgate Aéreo , Reanimação Cardiopulmonar/métodos , Massagem Cardíaca/instrumentação , Adulto , Pessoal Técnico de Saúde , Reanimação Cardiopulmonar/instrumentação , Competência Clínica , Estudos Cross-Over , Cardioversão Elétrica , Feminino , Humanos , Masculino , Manequins , Estudos Prospectivos , Fatores de Tempo
8.
Adv Mater ; 35(30): e2301837, 2023 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-37086448

RESUMO

Laser-driven phosphor-converted white light sources are highly desirable for their unprecedented energy efficiency and lighting quality. However, important challenges remain due to a lack of efficient and stable red-emitting materials. Here Eu2+ -activated oxide-based double perovskites are explored as red emitters with thermally stable photoluminescence. Sr3 TaO5.5 :Eu2+ ceramics exhibit a red emission band peaking at 620 nm upon blue laser pumping owing to the Eu2+ occupation at highly ordered substitutional lattice sites. A constructed laser-driven white light wheel under an incident power density of 19.2 W mm-2 presents a record luminous flux of 1115 lm with an excellent color rendering index of 90. This study invigorates the development of Eu2+ -activated oxide-based ceramics with thermally stable luminescence for laser-pumped lighting and display applications.

9.
Intervirology ; 55(2): 102-7, 2012.
Artigo em Inglês | MEDLINE | ID: mdl-22286877

RESUMO

BACKGROUND: Genotypic drug resistance testing provides essential information for guiding treatment in HIV-infected patients. It may either be used for identifying patients with transmitted drug resistance or to clarify reasons for treatment failure and to check for remaining treatment options. While different approaches for the interpretation of HIV sequence information are already available, no other available rules-based systems specifically have looked into the effects of combinations of drugs. HIV-GRADE (Genotypischer Resistenz Algorithmus Deutschland) was planned as a countrywide approach to establish standardized drug resistance interpretation in Germany and also to introduce rules for estimating the influence of mutations on drug combinations. The rules for HIV-GRADE are taken from the literature, clinical follow-up data and from a bioinformatics-driven interpretation system (geno2pheno([resistance])). HIV-GRADE presents the option of seeing the rules and results of other drug resistance algorithms for a given sequence simultaneously. METHODS: The HIV-GRADE rules-based interpretation system was developed by the members of the HIV-GRADE registered society. For continuous updates, this expert committee meets twice a year to analyze data from various sources. Besides data from clinical studies and the centers involved, published correlations for mutations with drug resistance and genotype-phenotype correlation data information from the bioinformatic models of geno2pheno are used to generate the rules for the HIV-GRADE interpretation system. A freely available online tool was developed on the basis of the Stanford HIVdb rules interpretation tool using the algorithm specification interface. Clinical validation of the interpretation system was performed on the data of treatment episodes consisting of sequence information, antiretroviral treatment and viral load, before and 3 months after treatment change. Data were analyzed using multiple linear regression. RESULTS: As the developed online tool allows easy comparison of different drug resistance interpretation systems, coefficients of determination (R(2)) were compared for the freely available rules-based systems. HIV-GRADE (R(2) = 0.40), Stanford HIVdb (R(2) = 0.40), REGA algorithm (R(2) = 0.36) and ANRS (R(2) = 0.35) had a very similar performance using this multiple linear regression model. CONCLUSION: The performance of HIV-GRADE is comparable to alternative rules-based interpretation systems. While there is still room for improvement, HIV-GRADE has been made publicly available to allow access to our approach regarding the interpretation of resistance against single drugs and drug combinations.


Assuntos
Algoritmos , Fármacos Anti-HIV/farmacologia , Biologia Computacional/métodos , HIV-1/efeitos dos fármacos , HIV-1/genética , Testes de Sensibilidade Microbiana/métodos , Tipagem Molecular/métodos , Alemanha , Infecções por HIV/virologia , Humanos , Internet
10.
AIDS Res Ther ; 8: 7, 2011 Feb 13.
Artigo em Inglês | MEDLINE | ID: mdl-21314993

RESUMO

BACKGROUND: Although being considered as a rarely observed HIV-1 protease mutation in clinical isolates, the L76V-prevalence increased 1998-2008 in some European countries most likely due to the approval of Lopinavir, Amprenavir and Darunavir which can select L76V. Beside an enhancement of resistance, L76V is also discussed to confer hypersusceptibility to the drugs Atazanavir and Saquinavir which might enable new treatment strategies by trying to take advantage of particular mutations. RESULTS: Based on a cohort of 47 L76V-positive patients, we examined if there might exist a clinical advantage for L76V-positive patients concerning long-term success of PI-containing regimens in patients with limited therapy options.Genotypic- and phenotypic HIV-resistance tests from 47 mostly multi-resistant, L76V-positive patients throughout Germany were accomplished retrospectively 1999-2009. Five genotype-based drug-susceptibility predictions received from online interpretation-tools for Atazanavir, Saquinavir, Amprenavir and Lopinavir, were compared to phenotype-based predictions that were determined by using a recombinant virus assay along with a Virtual Phenotype™(Virco). The clinical outcome of the L76V-adapted follow-up therapy was determined by monitoring viral load for 96 weeks. CONCLUSIONS: In this analysis, the mostly used interpretation systems overestimated the L76V-mutation concerning Atazanavir- and SQV resistance. In fact, a clear benefit in drug susceptibility for these drugs was observed in phenotype analysis after establishment of L76V. More importantly, long-term therapy success was significantly higher in patients receiving Atazanavir and/or Saquinavir plus one L76V-selecting drug compared to patients without L76V-selecting agents (p = 0.002).In case of L76V-occurrence ATV and/or SQV may represent encouraging options for patients in deep salvage situations.

11.
J Appl Physiol (1985) ; 130(1): 237-244, 2021 01 01.
Artigo em Inglês | MEDLINE | ID: mdl-33151777

RESUMO

Avalanche patients who are completely buried but still able to breathe are exposed to hypothermia, hypoxia, and hypercapnia (triple H syndrome). Little is known about how these pathological changes affect brain physiology. The study aim was to investigate the effect of hypothermia, hypoxia, and hypercapnia on brain oxygenation and systemic and cerebral hemodynamics. Anesthetized pigs were surface cooled to 28°C. Fraction of inspiratory oxygen ([Formula: see text]) was reduced to 17% and hypercapnia induced. Hemodynamic parameters and blood gas values were monitored. Cerebral measurements included cerebral perfusion pressure (CPP), brain tissue oxygen tension ([Formula: see text]), cerebral venous oxygen saturation ([Formula: see text]), and regional cerebral oxygen saturation (rSo2). Tests were interrupted when hemodynamic instability occurred or 60 min after hypercapnia induction. ANOVA for repeated measures was used to compare values across phases. There was no clinically relevant reduction in cerebral oxygenation ([Formula: see text], [Formula: see text], rSo2) during hypothermia and initial [Formula: see text] reduction. Hypercapnia was associated with an increase in pulmonary resistance followed by a decrease in cardiac output and CPP, resulting in hemodynamic instability and cerebral desaturation (decrease in [Formula: see text], [Formula: see text], rSo2). Hypercapnia may be the main cause of cardiovascular instability, which seems to be the major trigger for a decrease in cerebral oxygenation in triple H syndrome despite severe hypothermia.NEW & NOTEWORTHY Avalanche patients who are completely buried but still able to breathe are exposed to hypothermia, hypoxia, and hypercapnia (triple H syndrome). In a porcine model, there was no clinically relevant reduction in cerebral oxygenation during hypothermia and initial reduction of fraction of inspiratory oxygen ([Formula: see text]), as observed during hypercapnia. Hypercapnia may be the main cause of cardiovascular instability, which seems to be the major trigger for a decrease in cerebral oxygenation in triple H syndrome despite severe hypothermia.


Assuntos
Avalanche , Hipotermia , Animais , Encéfalo , Hemodinâmica , Humanos , Hipercapnia , Hipóxia , Oxigênio , Suínos
12.
Ther Hypothermia Temp Manag ; 11(1): 28-34, 2021 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-32758071

RESUMO

The understanding and neurological prognostication of hypoxic ischemic encephalopathy (HIE) after hypothermic cardiac arrest (CA) is limited. Recent data suggest that the protein tau (total tau) might be a useful marker for outcome in patients with HIE. This translational porcine study aimed to analyze brain physiology in relation to total tau protein release during hypothermic CA. Eight domestic pigs were studied as part of a prospective porcine study using cerebral microdialysis (CMD). CMD samples for tau analysis were collected at baseline, after reaching the targeted core temperature of 28°C (hypothermia), after hypoxic hypercapnia (partial asphyxia), and finally 20 minutes after cardiopulmonary resuscitation. CMD-total tau-protein was analyzed using enzyme-linked immunosorbent essay. Cerebral tau protein was slightly elevated at baseline most likely due to an insertion trauma, remained stable during hypercapnic hypoxia, and significantly (p = 0.009) increased in 8/8 pigs during resuscitation to 1335 pg/mL (interquartile range: 705-2100). CMD-tau release was associated with lower levels of brain tissue oxygen tension (p = 0.011), higher CMD-lactate/pyruvate ratio, higher CMD-lactate, CMD-glutamate, and CMD-glycerol levels (p < 0.001, respectively), but not with cerebral perfusion pressure, intracranial pressure, or CMD-glucose levels. This study demonstrates an immediate tau protein release accompanied by deranged cerebral metabolism and decreased brain tissue oxygen tension during mechanical resuscitation in hypothermic CA. Understanding tau physiology and release kinetics is important for the design and interpretation of studies investigating tau as a biomarker of HIE.


Assuntos
Parada Cardíaca , Hipotermia Induzida , Hipotermia , Animais , Encéfalo , Humanos , Microdiálise , Estudos Prospectivos , Sus scrofa , Suínos
13.
J Neurosci ; 29(42): 13377-88, 2009 Oct 21.
Artigo em Inglês | MEDLINE | ID: mdl-19846725

RESUMO

Peripheral tissue injury is associated with changes in protein expression in sensory neurons that may contribute to abnormal nociceptive processing. We used cultured dorsal root ganglion (DRG) neurons as a model of axotomized neurons to investigate early changes in protein expression after nerve injury. Comparing protein levels immediately after DRG dissociation and 24 h later by proteomic differential expression analysis, we found a substantial increase in the levels of the neurotrophin-inducible protein VGF (nonacronymic), a putative neuropeptide precursor. In a rodent model of nerve injury, VGF levels were increased within 24 h in both injured and uninjured DRG neurons, and the increase persisted for at least 7 d. VGF was also upregulated 24 h after hindpaw inflammation. To determine whether peptides derived from proteolytic processing of VGF participate in nociceptive signaling, we examined the spinal effects of AQEE-30 and LQEQ-19, potential proteolytic products shown previously to be bioactive. Each peptide evoked dose-dependent thermal hyperalgesia that required activation of the mitogen-activated protein kinase p38. In addition, LQEQ-19 induced p38 phosphorylation in spinal microglia when injected intrathecally and in the BV-2 microglial cell line when applied in vitro. In summary, our results demonstrate rapid upregulation of VGF in sensory neurons after nerve injury and inflammation and activation of microglial p38 by VGF peptides. Therefore, VGF peptides released from sensory neurons may participate in activation of spinal microglia after peripheral tissue injury.


Assuntos
Neuropeptídeos/metabolismo , Nociceptores/fisiologia , Doenças do Sistema Nervoso Periférico/metabolismo , Proteômica , Animais , Benzoxazóis/metabolismo , Células Cultivadas , Modelos Animais de Doenças , Relação Dose-Resposta a Droga , Inibidores Enzimáticos/farmacologia , Adjuvante de Freund , Gânglios Espinais/efeitos dos fármacos , Gânglios Espinais/metabolismo , Gânglios Espinais/patologia , Hiperalgesia/induzido quimicamente , Hiperalgesia/metabolismo , Imidazóis/farmacologia , Inflamação/induzido quimicamente , Inflamação/metabolismo , Masculino , Microglia/efeitos dos fármacos , Microglia/metabolismo , Neurônios Aferentes/metabolismo , Neuropeptídeos/química , Neuropeptídeos/farmacologia , Técnicas de Cultura de Órgãos , Medição da Dor/efeitos dos fármacos , Peptídeos/farmacologia , Doenças do Sistema Nervoso Periférico/etiologia , Doenças do Sistema Nervoso Periférico/patologia , Piridinas/farmacologia , Compostos de Quinolínio/metabolismo , Ratos , Ratos Sprague-Dawley , Tempo de Reação/efeitos dos fármacos , Receptor trkA/metabolismo , Receptores Purinérgicos P2/metabolismo , Receptores Purinérgicos P2X3 , Transdução de Sinais/efeitos dos fármacos , Traumatismos da Medula Espinal/metabolismo , Fatores de Tempo , Regulação para Cima/efeitos dos fármacos , Regulação para Cima/fisiologia
14.
Curr Opin Anaesthesiol ; 23(4): 500-6, 2010 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-20543679

RESUMO

PURPOSE OF REVIEW: Recently, notable progress has been made in the field of anesthesia drugs and airway management. RECENT FINDINGS: Anesthesia in prehospital emergencies and in the emergency department is reviewed and guidelines are discussed. SUMMARY: Preoxygenation should be performed with high-flow oxygen delivered through a tight-fitting face mask with a reservoir. Ketamine may be the induction agent of choice in hemodynamically unstable patients. The rocuronium antagonist sugammadex may have the potential to make rocuronium a first-line neuromuscular blocking agent in emergency induction. Experienced healthcare providers may consider prehospital anesthesia induction. Moderately experienced healthcare providers should optimize oxygenation, hasten hospital transfer and only try to intubate a patient whose life is threatened. When intubation fails twice, ventilation should be performed with an alternative supraglottic airway or a bag-valve-mask device. Lesser experienced healthcare providers should completely refrain from intubation, optimize oxygenation, hasten hospital transfer and ventilate patients only in life-threatening circumstances with a supraglottic airway or a bag-valve-mask device. Senior help should be sought early. In a 'cannot ventilate-cannot intubate' situation, a supraglottic airway should be employed and, if ventilation is still unsuccessful, a surgical airway should be performed. Capnography should be used in every ventilated patient. Clinical practice is essential to retain anesthesia and airway management skills.


Assuntos
Anestesia , Serviços Médicos de Emergência , Serviço Hospitalar de Emergência , Anestesia/efeitos adversos , Anestésicos/efeitos adversos , Medicina de Emergência/educação , Humanos , Intubação Intratraqueal , Monitorização Fisiológica , Oxigenoterapia , Respiração Artificial
15.
J Clin Virol ; 129: 104514, 2020 08.
Artigo em Inglês | MEDLINE | ID: mdl-32688328

RESUMO

BACKGROUND: Accurate molecular methods to detect and quantify hepatitis B virus (HBV) DNA are essential to diagnose chronic infections, guide treatment decisions, assess response to treatment, and determine risk of HBV-related complications. New generations of real-time HBV DNA assay platforms provide results in less than 2-3 h, with continuous loading of specimens and true random-access capability. OBJECTIVES: We examined the clinical performance of the new Alinity m HBV assay, run on the fully automated, continuous, random-access Alinity m platform, to accurately detect and quantify HBV DNA in a large series of patient samples infected with different HBV genotypes frequently encountered in clinical practice. STUDY DESIGN: This international, multisite study assessed the precision and reproducibility of the Alinity m HBV assay and compared its performance to four HBV assays currently in clinical use. RESULTS: The Alinity m HBV assay demonstrated linear quantitation of HBV DNA in plasma samples, with high precision (coefficient of variation 4.1 %-8.8 %) and reproducibility. The Alinity m HBV assay showed excellent correlation (correlation coefficients ≥0.947) with comparator HBV assays, with an overall observed bias ranging from -0.07 to 0.17 Log10 IU/mL. 97 % of quantifiable patient results were <1 Log10 IU/mL different than the respective comparator assays, with comparable results across HBV genotypes. CONCLUSIONS: The newly developed real-time PCR-based Alinity m HBV assay is sensitive, reproducible, and accurately quantifies HBV DNA levels from HBsAg-positive patients across the full dynamic range of quantification.


Assuntos
Vírus da Hepatite B , Hepatite B , DNA Viral , Vírus da Hepatite B/genética , Humanos , Reprodutibilidade dos Testes , Sensibilidade e Especificidade , Carga Viral
16.
J Clin Virol ; 129: 104530, 2020 08.
Artigo em Inglês | MEDLINE | ID: mdl-32688329

RESUMO

BACKGROUND: Accurate, rapid detection of HIV-1 RNA is critical for early diagnosis, treatment decision making, and long-term management of HIV-1 infection. OBJECTIVE: We evaluated the diagnostic performance of the Alinity m HIV-1 assay, which uses a dual target/dual probe design against highly conserved target regions of the HIV-1 genome and is run on the fully automated Alinity m platform. STUDY DESIGN: This was an international, multisite study that compared the diagnostic performance of the Alinity m HIV-1 assay to four commercially available HIV-1 assays routinely used in nine independent clinical laboratories. Alinity m HIV-1 assay precision, detectability, and reproducibility was compared across four study sites. RESULTS: The Alinity m HIV-1 assay produced comparable results to currently available HIV-1 assays (correlation coefficient >0.995), with an overall bias of -0.1 to 0.10 Log10 copies/mL. The Alinity m HIV-1 assay and its predecessor m2000 HIV-1 assay demonstrated comparable detection of 16 different HIV-1 subtypes (R2 = 0.956). A high level of agreement (>88 %) between all HIV-1 assays was seen near clinical decision points of 1.7 Log10 copies/mL (50 copies/mL) and 2.0 Log10 copies/mL (200 copies/mL). Alinity m HIV-1 assay precision was 0.08 and 0.21 Log10 copies/mL at VLs of 1000 and 50 copies/mL, respectively, with a high level of detectability (≥97 % hit rate) and reproducibility across sites. CONCLUSIONS: The Alinity m HIV-1 assay provides comparable diagnostic accuracy to current HIV-1 assays, and when run on the Alinity m system, has the capacity to shorten the time between diagnosis and treatment.


Assuntos
Infecções por HIV , HIV-1 , HIV-1/genética , Humanos , RNA Viral , Kit de Reagentes para Diagnóstico , Reprodutibilidade dos Testes , Sensibilidade e Especificidade , Carga Viral
17.
J Clin Virol ; 129: 104531, 2020 08.
Artigo em Inglês | MEDLINE | ID: mdl-32688330

RESUMO

BACKGROUND: Nucleic acid testing is essential for the detection and quantification of HCV RNA in the diagnosis of HCV infection and treatment monitoring. The Alinity m HCV assay was recently developed by Abbott Molecular for rapid detection and quantification of HCV RNA on the fully automated, continuous, random-access Alinity m analyzer. OBJECTIVES: Our study assessed the performance of the new Alinity m HCV assay for detection and quantification of HCV RNA in a large series of patient samples of various genotypes. This international, multicentric study evaluated the linearity, precision, and reproducibility of the Alinity m HCV assay and its performance in comparison to three other HCV assays currently used in clinical practice. RESULTS: The Alinity m HCV assay demonstrated high linearity (correlation coefficient r = 1.00), precision (coefficients of variation [CV] 6.6-13.5 %) and reproducibility (CV 1.7-4.3 % across three control lots). At a concentration near the lower limit of detection, the Alinity m HCV assay exhibited >98 % detectability. The Alinity m HCV assay showed excellent correlation with comparator HCV assays in serum (n = 406) and plasma (n = 1401) samples (correlation coefficients ≥0.96, bias 0.01 to 0.14 Log10 IU/mL). More than 95 % of the quantified results with the Alinity m HCV assay were less than mean bias ± 1.96 SD different from those of the comparator assays. CONCLUSIONS: The newly developed Alinity m HCV assay is sensitive, reproducible, and accurately quantifies HCV RNA levels in serum and plasma samples from patients with chronic HCV infection, with no impact of HCV genotype on assay performance.


Assuntos
Hepacivirus , Hepatite C , Genótipo , Hepacivirus/genética , Humanos , RNA Viral , Reprodutibilidade dos Testes , Sensibilidade e Especificidade , Carga Viral
18.
Resuscitation ; 128: 51-55, 2018 07.
Artigo em Inglês | MEDLINE | ID: mdl-29727706

RESUMO

BACKGROUND: Recent studies have shown that during cardiopulmonary resuscitation (CPR) head-up position (HUP) as compared to standard supine position (SUP) decreases intracranial pressure (ICP) and increases cerebral perfusion pressure (CPP). The impact of this manoeuvre on brain oxygenation and metabolism is not clear. We therefore investigated HUP as compared to SUP during basic life support (BLS) CPR for their effect on brain oxygenation and metabolism. METHODS: Twenty pigs were anaesthetized and instrumented. After 8 min of cardiac arrest (CA) pigs were randomized to either HUP or SUP and resuscitated mechanically for 20 min. Mean arterial pressure (MAP), ICP, CPP, cerebral regional oxygen saturation (rSO2) and brain tissue oxygen tension (PbtO2) were measured at baseline, after CA and every 5 min during CPR. Cerebral venous oxygen saturation (ScvO2) was measured at baseline, after CA and after 20 min of CPR. Cerebral microdialysis parameters, e.g. lactate/pyruvate ratio (L/P ratio) were taken at baseline and the end of the experiment. RESULTS: ICP was significantly lower in HUP compared to SUP animals after 5 min (18.0 ±â€¯4.5 vs. 24.1 ±â€¯5.2 mmHg; p = 0.033) and 20 min (12.0 ±â€¯3.4 vs. 17.8 ±â€¯4.3 mmHg; p = 0.023) of CPR. Accordingly, CPP was significantly higher in the HUP group after 5 min (11.2 ±â€¯9.5 vs. 1.0 ±â€¯9.2 mmHg; p = 0.045) and 20 min (3.4 ±â€¯6.4 vs. -3.8 ±â€¯2.8 mmHg; p = 0.023) of CPR. However, no difference was found in rSO2, PbtO2, ScvO2 and L/P ratio between groups after 20 min of CPR. CONCLUSION: In this animal model of BLS CPR, HUP as compared to SUP did not improve cerebral oxygenation or metabolism.


Assuntos
Reanimação Cardiopulmonar/métodos , Circulação Cerebrovascular/fisiologia , Parada Cardíaca/terapia , Pressão Intracraniana/fisiologia , Animais , Gasometria , Modelos Animais de Doenças , Parada Cardíaca/sangue , Parada Cardíaca/mortalidade , Distribuição Aleatória , Decúbito Dorsal/fisiologia , Suínos
19.
J Clin Virol ; 99-100: 50-56, 2018.
Artigo em Inglês | MEDLINE | ID: mdl-29328964

RESUMO

BACKGROUND: Hepatitis B viral load monitoring is an essential part of managing patients with chronic Hepatits B infection. Beckman Coulter has developed the VERIS HBV Assay for use on the fully automated Beckman Coulter DxN VERIS Molecular Diagnostics System.1 OBJECTIVES: To evaluate the analytical performance of the VERIS HBV Assay at multiple European virology laboratories. STUDY DESIGN: Precision, analytical sensitivity, negative sample performance, linearity and performance with major HBV genotypes/subtypes for the VERIS HBV Assay was evaluated. RESULTS: Precision showed an SD of 0.15 log10 IU/mL or less for each level tested. Analytical sensitivity determined by probit analysis was between 6.8-8.0 IU/mL. Clinical specificity on 90 unique patient samples was 100.0%. Performance with 754 negative samples demonstrated 100.0% not detected results, and a carryover study showed no cross contamination. Linearity using clinical samples was shown from 1.23-8.23 log10 IU/mL and the assay detected and showed linearity with major HBV genotypes/subtypes. CONCLUSIONS: The VERIS HBV Assay demonstrated comparable analytical performance to other currently marketed assays for HBV DNA monitoring.


Assuntos
Vírus da Hepatite B/genética , Hepatite B/sangue , Técnicas de Diagnóstico Molecular/métodos , Reação em Cadeia da Polimerase em Tempo Real , Carga Viral/métodos , Automação Laboratorial , Europa (Continente) , Genótipo , Humanos , Limite de Detecção , RNA Viral/sangue , RNA Viral/genética , Sensibilidade e Especificidade
20.
Eur J Med Res ; 12(9): 463-72, 2007 Oct 15.
Artigo em Inglês | MEDLINE | ID: mdl-17933728

RESUMO

Coreceptor tropism antagonists represent a new class of antiretrovirals for the treatment of HIV infection. The knowledge of patients' viral population tropism before the initiation of and during therapy with such compounds may be critical in order to optimize treatment strategies. In this review we focus on the characteristics of phenotypic assays for the determination of HIV coreceptor tropism. Beside traditional phenotypic assays, there are at least four phenotypic recombinant virus assays (RVA) available to predict coreceptor usage: Trofile (Monogram Biosciences), Phenoscript (VIRalliance), XtrackC/ PhenX-R (inPheno) and a platform developed by Virco. Trofile and Phenoscript represent single-cycle assays and are able to determine coreceptor tropism without cocultivation of HIV particles in cell culture. Trofile offers the most clinically validated data with currently about 25,000 analysed samples. The detection of minority variants is a limitation of all population-based assays and varies between 1 and 10%, depending on the assay used. XtrackC/PhenX-R and Virco's platform combine genotypic and phenotypic assays to analyze a patient's sample for tropism. Although all assays are validated for the assessment of coreceptor tropism in different HIV-1 subtypes, there is still a need for further evaluations. Furthermore, the establishment of cut-offs for X4 minority species will be difficult, and is affected by many factors like patient sample quality, the input volume, viral load, the detection limits and PCR variations. Overall, RVAs confirm efficiency and accuracy thus making them suitable for the clinical management of HIV infected individuals treated with coreceptor antagonists.


Assuntos
Infecções por HIV/virologia , HIV-1/fisiologia , Receptores CCR5/fisiologia , Receptores CXCR4/fisiologia , Internalização do Vírus , Bioensaio , Proteína gp120 do Envelope de HIV/genética , HIV-1/genética , Humanos , Fenótipo , Reação em Cadeia da Polimerase , Receptores CCR5/genética , Receptores CXCR4/genética , Replicação Viral
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA