Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 24
Filtrar
Mais filtros

Base de dados
Tipo de documento
Intervalo de ano de publicação
1.
Am J Respir Crit Care Med ; 206(11): 1361-1369, 2022 12 01.
Artigo em Inglês | MEDLINE | ID: mdl-35816621

RESUMO

Rationale: The triple-combination regimen elexacaftor/tezacaftor/ivacaftor (ELX/TEZ/IVA) was shown to be safe and efficacious in children aged 6 through 11 years with cystic fibrosis and at least one F508del-CFTR allele in a phase 3, open-label, single-arm study. Objectives: To further evaluate the efficacy and safety of ELX/TEZ/IVA in children 6 through 11 years of age with cystic fibrosis heterozygous for F508del and a minimal function CFTR mutation (F/MF genotypes) in a randomized, double-blind, placebo-controlled phase 3b trial. Methods: Children were randomized to receive either ELX/TEZ/IVA (n = 60) or placebo (n = 61) during a 24-week treatment period. The dose of ELX/TEZ/IVA administered was based on weight at screening, with children <30 kg receiving ELX 100 mg once daily, TEZ 50 mg once daily, and IVA 75 mg every 12 hours, and children ⩾30 kg receiving ELX 200 mg once daily, TEZ 100 mg once daily, and IVA 150 mg every 12 hours (adult dose). Measurements and Main Results: The primary endpoint was absolute change in lung clearance index2.5 from baseline through Week 24. Children given ELX/TEZ/IVA had a mean decrease in lung clearance index2.5 of 2.29 units (95% confidence interval [CI], 1.97-2.60) compared with 0.02 units (95% CI, -0.29 to 0.34) in children given placebo (between-group treatment difference, -2.26 units; 95% CI, -2.71 to -1.81; P < 0.0001). ELX/TEZ/IVA treatment also led to improvements in the secondary endpoint of sweat chloride concentration (between-group treatment difference, -51.2 mmol/L; 95% CI, -55.3 to -47.1) and in the other endpoints of percent predicted FEV1 (between-group treatment difference, 11.0 percentage points; 95% CI, 6.9-15.1) and Cystic Fibrosis Questionnaire-Revised Respiratory domain score (between-group treatment difference, 5.5 points; 95% CI, 1.0-10.0) compared with placebo from baseline through Week 24. The most common adverse events in children receiving ELX/TEZ/IVA were headache and cough (30.0% and 23.3%, respectively); most adverse events were mild or moderate in severity. Conclusions: In this first randomized, controlled study of a cystic fibrosis transmembrane conductance regulator modulator conducted in children 6 through 11 years of age with F/MF genotypes, ELX/TEZ/IVA treatment led to significant improvements in lung function, as well as robust improvements in respiratory symptoms and cystic fibrosis transmembrane conductance regulator function. ELX/TEZ/IVA was generally safe and well tolerated in this pediatric population with no new safety findings.


Assuntos
Regulador de Condutância Transmembrana em Fibrose Cística , Fibrose Cística , Criança , Humanos , Aminofenóis/efeitos adversos , Benzodioxóis/efeitos adversos , Agonistas dos Canais de Cloreto/efeitos adversos , Fibrose Cística/tratamento farmacológico , Fibrose Cística/genética , Regulador de Condutância Transmembrana em Fibrose Cística/genética , Regulador de Condutância Transmembrana em Fibrose Cística/uso terapêutico , Volume Expiratório Forçado , Mutação
2.
Curr Opin Organ Transplant ; 22(3): 281-286, 2017 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-28266941

RESUMO

PURPOSE OF REVIEW: Herein, we review the field of subzero organ preservation with a focus on recent developments in hepatic supercooling. RECENT FINDINGS: Organ preservation is making a rapid shift from the decade old standard of storage on ice toward techniques that improve organ availability as well as preservation time. Long-term organ preservation would have tremendous benefits to the organ transplantation field, including better organ allocation, donor-recipient matching, as well as reduced preservation injury, and subsequent improvement of donor organ use. The formation of ice has proven an important limiting factor and novel techniques attempt to control or prevent freezing using cryoprotective agents, and highly controlled cooling regimens. Various techniques have been employed over the previous decades, including true organ freezing, vitrification, and subzero nonfreezing or supercooling. For most techniques, successful transplantation following long-term subzero preservation has remained elusive. Supercooling, however, recently delivered the first promising results, yielding survival after up to 4 days of supercooled preservation at -6°C. SUMMARY: As the field of organ preservation undergoes significant development, the field of subzero preservation also receives renewed interest. Although many obstacles remain to be overcome to make subzero preservation feasible, novel techniques are beginning to show their potential in achieving long-term preservation.


Assuntos
Criopreservação/métodos , Transplante de Fígado/métodos , Fígado/patologia , Preservação de Órgãos/métodos , Animais , Anuros , Humanos
3.
J Hepatol ; 60(6): 1172-9, 2014 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-24560661

RESUMO

BACKGROUND & AIMS: The peribiliary glands of large bile ducts have been identified as a niche of progenitor cells that contribute to regeneration of biliary epithelium after injury. We aimed to determine whether injury to the peribiliary glands of donor livers is a risk factor for development of non-anastomotic biliary strictures (NAS) after liver transplantation. METHODS: In 128 liver transplant procedures, biopsies were taken from the donor bile duct and injury was assessed using an established histological grading system. Histological severity of injury was subsequently compared in liver grafts that later developed biliary structures vs. uncomplicated liver grafts. RESULTS: Luminal biliary epithelial loss >50% was observed in 91.8% of the grafts before transplantation, yet NAS occurred in only 16.4%. Periluminal peribiliary glands were more severely injured than deep peribiliary glands located near the fibromuscular layer (>50% loss in 56.9% vs. 17.5%, respectively; p<0.001). Injury of deep peribiliary glands was more prevalent and more severe in livers that later developed NAS, compared to grafts without NAS (>50% loss in 50.0% vs. 9.8%, respectively; p=0.004). In parallel, injury of the peribiliary vascular plexus was more severe in livers that developed NAS, compared to grafts without NAS (>50% vascular changes in 57.1% vs. 20.3%; p=0.006). CONCLUSION: Injury of peribiliary glands and vascular plexus before transplantation is strongly associated with the occurrence of biliary strictures after transplantation. This suggests that insufficient regeneration due to loss of peribiliary glands or impaired blood supply may explain the development of biliary strictures.


Assuntos
Ductos Biliares Extra-Hepáticos/lesões , Ductos Biliares Extra-Hepáticos/patologia , Colestase/etiologia , Circulação Hepática , Transplante de Fígado/efeitos adversos , Adulto , Colestase/patologia , Epitélio/patologia , Epitélio/fisiologia , Feminino , Sobrevivência de Enxerto/fisiologia , Humanos , Isquemia/etiologia , Isquemia/patologia , Masculino , Pessoa de Meia-Idade , Valor Preditivo dos Testes , Regeneração/fisiologia , Nicho de Células-Tronco , Doadores de Tecidos
4.
J Cyst Fibros ; 22(1): 119-123, 2023 01.
Artigo em Inglês | MEDLINE | ID: mdl-36114142

RESUMO

Elexacaftor/tezacaftor/ivacaftor (ELX/TEZ/IVA) was shown to be safe and efficacious in people with cystic fibrosis (CF) heterozygous for F508del and a minimal function mutation (F/MF) or homozygous for F508del (F/F) in two pivotal Phase 3 trials, significantly improving percentage predicted forced expiratory volume in 1 second, Cystic Fibrosis Questionnaire-Revised, Respiratory Domain (CFQ-R RD) scores, and sweat chloride concentration. Here, we analyzed the 11 non-respiratory domains (non-RDs) of the CFQ-R, which assess general health-related quality of life (i.e., Physical Functioning, Role Functioning, Vitality, Health Perceptions, Emotional Functioning, and Social Functioning) and quality of life impacted by CF (i.e., Body Image, Eating Problems, Treatment Burden, Weight, and Digestive Symptoms), for participants in these two Phase 3 trials. ELX/TEZ/IVA treatment led to higher scores in all CFQ-R non-RDs, with improvements in most domains compared with control treatments. These findings demonstrate that ELX/TEZ/IVA improves a range of CF-specific symptoms and general functioning and well-being.


Assuntos
Fibrose Cística , Humanos , Aminofenóis , Benzodioxóis , Agonistas dos Canais de Cloreto , Fibrose Cística/diagnóstico , Regulador de Condutância Transmembrana em Fibrose Cística/genética , Mutação , Qualidade de Vida
5.
Lancet Respir Med ; 10(3): 267-277, 2022 03.
Artigo em Inglês | MEDLINE | ID: mdl-34942085

RESUMO

BACKGROUND: Elexacaftor plus tezacaftor plus ivacaftor is a triple-combination cystic fibrosis transmembrane conductance regulator (CFTR) modulator regimen shown to be generally safe and efficacious in people with cystic fibrosis aged 12 years or older with at least one F508del-CFTR allele. We aimed to assess the magnitude and durability of the clinical effects of this triple combination regimen in people with cystic fibrosis homozygous for the F508del-CFTR mutation. METHODS: We conducted a multicentre, randomised, double-blind, active-controlled, phase 3b trial of elexacaftor plus tezacaftor plus ivacaftor at 35 medical centres in Australia, Belgium, Germany, and the UK. Eligible participants were those with cystic fibrosis homozygous for the F508del-CFTR mutation, aged 12 years or older with stable disease, and with a percent predicted FEV1 of 40-90% inclusive. After a 4-week run-in period, in which participants received tezacaftor 100 mg orally once daily and ivacaftor 150 mg orally every 12 h, participants were randomly assigned (1:1) to receive 24 weeks of either elexacaftor 200 mg orally once daily plus tezacaftor 100 mg orally once daily plus ivacaftor 150 mg orally every 12 h (elexacaftor plus tezacaftor plus ivacaftor group) or tezacaftor 100 mg orally once daily plus ivacaftor 150 mg orally every 12 h (tezacaftor plus ivacaftor group). Randomisation was stratified by percent predicted FEV1, age at screening visit, and whether the participant was receiving CFTR modulators at the time of the screening visit. Patients, investigators, and sponsor's study execution team were masked to treatment assignment. The primary endpoint was the absolute change in Cystic Fibrosis Questionnaire-Revised (CFQ-R) respiratory domain score from baseline (ie, at the end of the tezacaftor plus ivacaftor run-in period) up to and including week 24. The key secondary endpoint was the absolute change from baseline in percent predicted FEV1 up to and including week 24; other secondary endpoints were the absolute change from baseline in sweat chloride concentrations up to and including week 24, and safety and tolerability. All endpoints were assessed in all randomised patients who had received at least one dose of their assigned regimen. This study is registered with ClinicalTrials.gov, NCT04105972. FINDINGS: Between Oct 3, 2019, and July 24, 2020, 176 participants were enrolled. Following the 4-week tezacaftor plus ivacaftor run-in period, 175 participants were randomly assigned (87 to the elexacaftor plus tezacaftor plus ivacaftor group and 88 to the tezacaftor plus ivacaftor group) and dosed in the treatment period. From baseline up to and including week 24, the mean CFQ-R respiratory domain score increased by 17·1 points (95% CI 14·1 to 20·1) in the elexacaftor plus tezacaftor plus ivacaftor group and by 1·2 points (-1·7 to 4·2) in the tezacaftor plus ivacaftor group (least squares mean treatment difference 15·9 points [95% CI 11·7 to 20·1], p<0·0001), the mean percent predicted FEV1 increased by 11·2 percentage points (95% CI 9·8 to 12·6) in the elexacaftor plus tezacaftor plus ivacaftor group and by 1·0 percentage points (-0·4 to 2·4) in the tezacaftor plus ivacaftor group (least squares mean treatment difference 10·2 percentage points [8·2 to 12·1], p<0·0001), and the mean sweat chloride concentration decreased by 46·2 mmol/L (95% CI 43·7 to 48·7) in the elexacaftor plus tezacaftor plus ivacaftor group and by 3·4 mmol/L (1·0 to 5·8) in the tezacaftor plus ivacaftor group (least squares mean treatment difference -42·8 mmol/L [-46·2 to -39·3], nominal p<0·0001). Most participants (70 [80%] in the elexacaftor plus tezacaftor plus ivacaftor group and 74 [84%] in the tezacaftor plus ivacaftor group) had adverse events that were mild or moderate in severity; serious adverse events occurred in five (6%) of 87 participants in the elexacaftor plus tezacaftor plus ivacaftor group and 14 (16%) of 88 participants in the tezacaftor plus ivacaftor group. One (1%) participant in the elexacaftor plus tezacaftor plus ivacaftor group discontinued treatment due to an adverse event of anxiety and depression. Two (2%) participants in the tezacaftor plus ivacaftor group discontinued treatment due to adverse events of psychotic disorder (n=1) and obsessive-compulsive disorder (n=1). INTERPRETATION: The elexacaftor plus tezacaftor plus ivacaftor regimen was safe and well tolerated, and led to significant and clinically meaningful improvements in respiratory-related quality of life and lung function, as well as improved CFTR function, changes that were durable over 24 weeks and superior to those seen with tezacaftor plus ivacaftor in this patient population. FUNDING: Vertex Pharmaceuticals.


Assuntos
Fibrose Cística , Aminofenóis/uso terapêutico , Benzodioxóis/uso terapêutico , Criança , Agonistas dos Canais de Cloreto/uso terapêutico , Fibrose Cística/tratamento farmacológico , Fibrose Cística/genética , Regulador de Condutância Transmembrana em Fibrose Cística/genética , Método Duplo-Cego , Humanos , Indóis , Mutação , Pirazóis , Piridinas , Pirrolidinas , Qualidade de Vida , Quinolonas
6.
J Cyst Fibros ; 20(2): 228-233, 2021 03.
Artigo em Inglês | MEDLINE | ID: mdl-32586736

RESUMO

BACKGROUND: Increased rates of respiratory adverse events have been observed in people ≥12 years of age with cystic fibrosis homozygous for the Phe508del-CFTR mutation treated with lumacaftor/ivacaftor, particularly in those with percent predicted forced expiratory volume in 1 s (ppFEV1) of <40%. We evaluated the safety, tolerability, and efficacy of tezacaftor/ivacaftor in people with cystic fibrosis homozygous for Phe508del-CFTR who discontinued lumacaftor/ivacaftor due to treatment-related respiratory signs or symptoms. METHODS: Participants ≥12 years of age with cystic fibrosis homozygous for Phe508del-CFTR with ppFEV1 of ≥25% and ≤90% were randomized 1:1 and treated with tezacaftor/ivacaftor or placebo for 56 days. RESULTS: Of 97 participants, 94 (96.9%) completed the study. The primary endpoint was incidence of predefined respiratory adverse events of special interest (chest discomfort, dyspnea, respiration abnormal, asthma, bronchial hyperreactivity, bronchospasm, and wheezing): tezacaftor/ivacaftor, 14.0%; placebo, 21.3%. The adverse events were mild or moderate in severity. None were serious or led to treatment interruption or discontinuation. Overall, the discontinuation rate was similar between groups. The mean (SD) ppFEV1 at baseline was 44.6% (16.1%) with tezacaftor/ivacaftor and 48.0% (18.1%) with placebo. The posterior mean difference in absolute change in ppFEV1 from baseline to the average value of days 28 and 56 was 2.7 percentage points with tezacaftor/ivacaftor vs placebo. CONCLUSIONS: Tezacaftor/ivacaftor was generally safe, well tolerated, and efficacious in people ≥12 years of age with cystic fibrosis homozygous for Phe508del-CFTR with ppFEV1 of ≥25% and ≤90% who previously discontinued lumacaftor/ivacaftor due to treatment-related respiratory signs or symptoms.


Assuntos
Aminofenóis/efeitos adversos , Aminofenóis/uso terapêutico , Aminopiridinas/efeitos adversos , Benzodioxóis/efeitos adversos , Benzodioxóis/uso terapêutico , Agonistas dos Canais de Cloreto/uso terapêutico , Fibrose Cística/tratamento farmacológico , Indóis/uso terapêutico , Quinolonas/efeitos adversos , Quinolonas/uso terapêutico , Adolescente , Adulto , Agonistas dos Canais de Cloreto/efeitos adversos , Fibrose Cística/genética , Fibrose Cística/fisiopatologia , Regulador de Condutância Transmembrana em Fibrose Cística/genética , Método Duplo-Cego , Combinação de Medicamentos , Feminino , Humanos , Masculino , Testes de Função Respiratória
7.
Transplantation ; 103(2): 363-370, 2019 02.
Artigo em Inglês | MEDLINE | ID: mdl-30422952

RESUMO

BACKGROUND: Donation after circulatory death (DCD) liver grafts are known to be predisposed to primary nonfunction and ischemic cholangiopathy. Many DCD grafts are discarded because of older donor age or long warm ischemia times. Thus, it is critical to improve the quality of DCD liver grafts. Here, we have tested whether an enriched oxygen carrier added to the preservation solution can prolong graft survival and reduce biliary damage. METHODS: We assessed the adenosine triphosphate (ATP) content decay of mouse liver grafts after cold ischemia, warm ischemia, and combined warm+cold ischemia. In addition, we used a rat model of liver transplantation to compare survival of DCD grafts preserved in high-oxygen solution (preoxygenated perfluorocarbon [PFC] + University of Wisconsin [UW] solution) versus lower oxygen solution (preoxygenated UW solution). RESULTS: Adenosine triphosphate levels under UW preservation fall to less than 10% after 30 minutes of warm ischemia. Preoxygenated UW solution with PFC reached a significantly higher PaO2. After 45 minutes of warm ischemia in oxygenated UW + PFC solution, grafts showed 63% higher levels of ATP (P = 0.011). In addition, this was associated with better preservation of morphology when compared to grafts stored in standard UW solution. Animals that received DCD grafts preserved in higher oxygenation solution showed improved survival: 4 out of 6 animals survived long-term whereas all control group animals died within 24 hours. CONCLUSIONS: The additional oxygen provided by PFC during static cold preservation of DCD livers can better sustain ATP levels, and thereby reduce the severity of ischemic tissue damage. PFC-based preservation solution extends the tolerance to warm ischemia, and may reduce the rate of ischemic cholangiopathy.


Assuntos
Trifosfato de Adenosina/metabolismo , Sobrevivência de Enxerto/efeitos dos fármacos , Transplante de Fígado , Soluções para Preservação de Órgãos/farmacologia , Oxigênio/farmacologia , Adenosina/farmacologia , Alopurinol/farmacologia , Animais , Isquemia Fria , Fluorocarbonos/farmacologia , Glutationa/farmacologia , Insulina/farmacologia , Masculino , Preservação de Órgãos , Rafinose/farmacologia , Ratos , Ratos Endogâmicos Lew , Isquemia Quente
8.
J Clin Transl Res ; 4(1): 1-46, 2018 May 28.
Artigo em Inglês | MEDLINE | ID: mdl-30761355

RESUMO

BACKGROUND: Liver regeneration following partial hepatectomy (PHx) is a complicated process involving multiple organs and several types of signaling networks. The bile acid-activated metabolic pathways occupy an auxiliary yet important chapter in the entire biochemical story. PHx is characterized by rapid but transient bile acid overload in the liver, which constitutes the first wave of proliferative signaling in the remnant hepatocytes. Bile acids trigger hepatocyte proliferation through activation of several nuclear receptors. Following biliary passage into the intestines, enterocytes reabsorb the bile acids, which results in the activation of farnesoid X receptor (FXR), the consequent excretion of fibroblast growth factor (FGF)19/FGF15, and its release into the enterohepatic circulation. FGF19/FGF15 subsequently binds to its cognate receptor, fibroblast growth factor receptor 4 (FGFR4) complexed with ß-klotho, on the hepatocyte membrane, which initiates the second wave of proliferative signaling. Because some bile acids are toxic, the remnant hepatocytes must resolve the potentially detrimental state of bile acid excess. Therefore, the hepatocytes orchestrate a bile acid detoxification and elimination response as a protective mechanism in concurrence with the proliferative signaling. The response in part results in the excretion of (biotransformed) bile acids into the canalicular system, causing the bile acids to end up in the intestines. RELEVANCE FOR PATIENTS: Recently, FXR agonists have been shown to promote regeneration via the gut-liver axis. This type of pharmacological intervention may prove beneficial for patients with hepatobiliary tumors undergoing PHx. In light of these developments, the review provides an in-depth account of the pathways that underlie post-PHx liver regeneration in the context of bile acid homeostasis in the liver and the gut-liver signaling axis.

9.
Technology (Singap World Sci) ; 5(4): 196-200, 2017 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-31106253

RESUMO

Machine perfusion-based organ preservation techniques are prudently transitioning into clinical practice. Although experimental data is compelling, the outcomes in the highly variable clinical donation-transplantation setting are unpredictable. Here, we offer an intermediate tool for pre-clinical assessment of human donor livers. We present a model for ex situ reperfusion of discarded human livers and report on its application in three human livers that have undergone subnormothermic (21°C) machine perfusion as an experimental preservation method. During reperfusion, the livers macroscopically reperfused in the first 15 minutes, and remained visually well-perfused for 3 hours of ex situ reperfusion. Bile production and oxygen consumption were observed throughout ex situ reperfusion. ATP levels increased 4.25-fold during SNMP. Between the end of SNMP and the end of reperfusion ATP levels dropped 45%. ALT levels in blood increased rapidly in the first 30 minutes and ALT release continued to taper off towards the end of perfusion. Release of CRP, TNF-α, IL-1ß, and IL-12, IFN-γ was sustained during reperfusion. These findings support the use of this model for the evaluation of novel human liver preservation techniques.

10.
Transplantation ; 101(7): 1637-1644, 2017 07.
Artigo em Inglês | MEDLINE | ID: mdl-28230641

RESUMO

BACKGROUND: The ongoing shortage of donor livers for transplantation and the increased use of marginal livers necessitate the development of accurate pretransplant tests of viability. Considering the importance energy status during transplantation, we aimed to correlate peritransplant energy cofactors to posttransplant outcome and subsequently model this in an ex vivo setting. METHODS: Sequential biopsies were taken from 19 donor livers postpreservation, as well as 30 minutes after portal venous reperfusion and hepatic arterial reperfusion and analyzed by liquid chromatography-mass spectrometry for energetic cofactors (adenosine triphosphate [ATP]/adenosine diphosphate [ADP]/adenosine monophosphate [AMP], nicotinamide adenine dinucleotide /NAD, nicotinamide adenine dinucleotide phosphate / nicotinamide adenine dinucleotide phosphate , flavin adenine dinucleotide , glutathione disulfide/glutathione). Energy status was correlated to posttransplant outcome. In addition, 4 discarded human donation after circulatory death livers were subjected to ex vivo reperfusion, modeling reperfusion injury and were similarly analyzed for energetic cofactors. RESULTS: A rapid shift toward higher energy adenine nucleotides was observed following clinical reperfusion, with a 2.45-, 3.17- and 2.12-fold increase in ATP:ADP, ATP:AMP and energy charge after portal venous reperfusion, respectively. Seven of the 19 grafts developed early allograft dysfunction. Correlation with peritransplant cofactors revealed a significant difference in EC between early allograft dysfunction and normal functioning grafts (0.09 vs 0.31, P < 0.05). In the simulated reperfusion model, a similar trend in adenine nucleotide changes was observed. CONCLUSIONS: A preserved energy status appears critical in the peritransplant period. Levels of adenine nucleotides change rapidly after reperfusion and ratios of ATP/ADP/AMP after reperfusion are significantly correlated to graft function. Using these markers as a viability test in combination with ex vivo reperfusion may provide a useful predictor of outcome that incorporates donor, preservation, and reperfusion factors.


Assuntos
Nucleotídeos de Adenina/metabolismo , Metabolismo Energético , Transplante de Fígado/métodos , Fígado/cirurgia , Doadores de Tecidos/provisão & distribuição , Adolescente , Adulto , Idoso , Biomarcadores/metabolismo , Biópsia , Citocinas/metabolismo , Feminino , Humanos , Mediadores da Inflamação/metabolismo , Fígado/metabolismo , Fígado/patologia , Transplante de Fígado/efeitos adversos , Masculino , Pessoa de Meia-Idade , Perfusão/efeitos adversos , Traumatismo por Reperfusão/etiologia , Traumatismo por Reperfusão/metabolismo , Estudos Retrospectivos , Fatores de Tempo , Sobrevivência de Tecidos , Resultado do Tratamento , Adulto Jovem
11.
PeerJ ; 4: e1571, 2016.
Artigo em Inglês | MEDLINE | ID: mdl-26819842

RESUMO

During the past decade, irreversible electroporation (IRE) ablation has emerged as a promising tool for the treatment of multiple diseases including hepatic cancer. However, the mechanisms behind the tissue regeneration following IRE ablation have not been investigated. Our results indicate that IRE treatment immediately kills the cells at the treatment site preserving the extracellular architecture, in effect causing in vivo decellularization. Over the course of 4 weeks, progenitor cell differentiation, through YAP and notch pathways, together with hepatocyte expansion led to almost complete regeneration of the ablated liver leading to the formation of hepatocyte like cells at the ablated zone. We did not observe significant scarring or tumor formation at the regenerated areas 6 months post IRE. Our study suggests a new model to study the regeneration of liver when the naïve extracellular matrix is decellularized in vivo with completely preserved extracellular architecture.

12.
Sci Rep ; 6: 22415, 2016 Mar 03.
Artigo em Inglês | MEDLINE | ID: mdl-26935866

RESUMO

As donor organ shortages persist, functional machine perfusion is under investigation to improve preservation of the donor liver. The transplantation of donation after circulatory death (DCD) livers is limited by poor outcomes, but its application may be expanded by ex vivo repair and assessment of the organ before transplantation. Here we employed subnormothermic (21 °C) machine perfusion of discarded human livers combined with metabolomics to gain insight into metabolic recovery during machine perfusion. Improvements in energetic cofactors and redox shifts were observed, as well as reversal of ischemia-induced alterations in selected pathways, including lactate metabolism and increased TCA cycle intermediates. We next evaluated whether DCD livers with steatotic and severe ischemic injury could be discriminated from 'transplantable' DCD livers. Metabolomic profiling was able to cluster livers with similar metabolic patterns based on the degree of injury. Moreover, perfusion parameters combined with differences in metabolic factors suggest variable mechanisms that result in poor energy recovery in injured livers. We conclude that machine perfusion combined with metabolomics has significant potential as a clinical instrument for the assessment of preserved livers.


Assuntos
Fígado/metabolismo , Metaboloma , Preservação de Órgãos , Perfusão , Feminino , Humanos , Transplante de Fígado , Masculino , Preservação de Órgãos/instrumentação , Preservação de Órgãos/métodos , Perfusão/instrumentação , Perfusão/métodos
13.
Nat Protoc ; 10(3): 495-507, 2015 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-25719268

RESUMO

Bariatric surgery is the only definitive solution currently available for the present obesity pandemic. These operations typically involve reconfiguration of gastrointestinal tract anatomy and impose profound metabolic and physiological benefits, such as substantially reducing body weight and ameliorating type II diabetes. Therefore, animal models of these surgeries offer unique and exciting opportunities to delineate the underlying mechanisms that contribute to the resolution of obesity and diabetes. Here we describe a standardized procedure for mouse and rat models of Roux-en-Y gastric bypass (80-90 min operative time) and sleeve gastrectomy (30-45 min operative time), which, to a high degree, resembles operations in humans. We also provide detailed protocols for both pre- and postoperative techniques that ensure a high success rate in the operations. These protocols provide the opportunity to mechanistically investigate the systemic effects of the surgical interventions, such as regulation of body weight, glucose homeostasis and gut microbiome.


Assuntos
Gastrectomia/métodos , Derivação Gástrica/métodos , Modelos Animais , Animais , Camundongos , Ratos
14.
Sci Rep ; 5: 8485, 2015 Feb 16.
Artigo em Inglês | MEDLINE | ID: mdl-25684630

RESUMO

Irreversible electroporation (IRE) is an emerging, minimally invasive technique for solid tumors ablation, under clinical investigation for cancer therapy. IRE affects only the cell membrane, killing cells while preserving the extracellular matrix structure. Current reports indicate tumors recurrence rate after IRE averaging 31% of the cases, of which 10% are local recurrences. The mechanisms for these recurrences are not known and new explanations for incomplete cell death are needed. Using finite elements method for electric field distribution, we show that presence of vascular structures with blood leads to the redistribution of electric fields leading to the areas with more than 60% reduced electric field strength in proximity to large blood vessels and clustered vessel structures. In an in vivo rat model of liver IRE ablation, we show that cells located in the proximity of larger vessel structures and in proximity of clustered vessel structures appear less affected by IRE ablation than cells in the tissue parenchyma or in the proximity of small, more isolated vessels. These findings suggest a role for "electric field sinks" in local tumors recurrences after IRE and emphasize the importance of the precise mapping of the targeted organ structure and conductivity for planning of electroporation procedures.


Assuntos
Sobrevivência Celular , Eletroporação , Animais , Eletricidade , Eletroporação/métodos , Feminino , Fígado/citologia , Fígado/patologia , Modelos Teóricos , Ratos
15.
J Clin Transl Res ; 1(1): 48-56, 2015 Jul 20.
Artigo em Inglês | MEDLINE | ID: mdl-30873444

RESUMO

BACKGROUND: Tissue-engineered liver grafts may offer a viable alternative to orthotopic liver transplantation and help overcome the donor organ shortage. Decellularized liver matrices (DLM) have a preserved vasculature and sustain hepatocellular function in culture, but graft survival after transplantation remains limited due to thrombogenicity of the matrix. AIM: To evaluate the effect of heparin immobilization on DLM thrombogenicity. METHODS: Heparin was immobilized on DLMs by means of layer-by-layer deposition. Grafts with 4 or 8 bilayers and 2 or 4 g/L of heparin were recellularized with primary rat hepatocytes and maintained in culture for 5 days. Hemocompatibility of the graft was assessed by ex vivo diluted whole-blood perfusion and heterotopic transplantation. RESULTS: Heparin was deposited throughout the matrix and the heparin content in the graft was higher with increasing number of bilayers and concentration of heparin. Recellularization and in vitro albumin and urea production were unaffected by heparinization. Resistance to blood flow during ex vivo perfusion was lower with increased heparinization and, macroscopically, no clots were visible in grafts with 8 bilayers. Following transplantation, flow through the graft was limited in all groups. Histological evidence of thrombosis was lower in heparinized DLMs, but transplantation of DLM grafts was not improved. CONCLUSIONS: Layer-by-layer deposition of heparin on a DLM is an effective method of immobilizing heparin throughout the graft and does not impede recellularization or hepatocellular function in vitro. Thrombogenicity during ex vivo blood perfusion was reduced in heparinized grafts and optimal with 8 bilayers, but transplantation remained unsuccessful with this method. RELEVANCE FOR PATIENTS: Tissue engineered liver grafts may offer a viable solution to dramatic shortages in donor organs.

16.
PLoS One ; 10(3): e0123421, 2015.
Artigo em Inglês | MEDLINE | ID: mdl-25822248

RESUMO

BACKGROUND: Liver transplantation plays a pivotal role in the treatment of patients with end-stage liver disease. Despite excellent outcomes, the field is strained by a severe shortage of viable liver grafts. To meet high demands, attempts are made to increase the use of suboptimal livers by both pretransplant recovery and assessment of donor livers. Here we aim to assess hepatic injury in the measurement of routine markers in the post-ischemic flush effluent of discarded human liver with a wide warm ischemic range. METHODS: Six human livers discarded for transplantation with variable warm and cold ischemia times were flushed at the end of preservation. The liver grafts were flushed with NaCl or Lactated Ringer's, 2 L through the portal vein and 1 L through the hepatic artery. The vena caval effluent was sampled and analyzed for biochemical markers of injury; lactate dehydrogenase (LDH), alanine transaminase (ALT), and alkaline phosphatase (ALP). Liver tissue biopsies were analyzed for ATP content and histologically (H&E) examined. RESULTS: The duration of warm ischemia in the six livers correlated significantly to the concentration of LDH, ALT, and ALP in the effluent from the portal vein flush. No correlation was found with cold ischemia time. Tissue ATP content at the end of preservation correlated very strongly with the concentration of ALP in the arterial effluent (P<0.0007, R2 = 0.96). CONCLUSION: Biochemical injury markers released during the cold preservation period were reflective of the duration of warm ischemic injury sustained prior to release of the markers, as well as the hepatic energy status. As such, assessment of the flush effluent at the end of cold preservation may be a useful tool in evaluating suboptimal livers prior to transplantation, particularly in situations with undeterminable ischemic durations.


Assuntos
Biomarcadores/metabolismo , Fígado/metabolismo , Fígado/patologia , Isquemia Quente/efeitos adversos , Trifosfato de Adenosina/metabolismo , Adulto , Idoso , Alanina Transaminase/metabolismo , Aspartato Aminotransferases/metabolismo , Isquemia Fria/métodos , Criopreservação/métodos , Feminino , Artéria Hepática/metabolismo , Artéria Hepática/patologia , Humanos , L-Lactato Desidrogenase/metabolismo , Transplante de Fígado/efeitos adversos , Transplante de Fígado/métodos , Masculino , Pessoa de Meia-Idade , Preservação de Órgãos/métodos , Soluções para Preservação de Órgãos/metabolismo , Veia Porta/metabolismo , Veia Porta/patologia
17.
Nat Protoc ; 10(3): 484-94, 2015 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-25692985

RESUMO

The current standard for liver preservation involves cooling of the organ on ice (0-4 °C). Although it is successful for shorter durations, this method of preservation does not allow long-term storage of the liver. The gradual loss of hepatic viability during preservation puts pressure on organ sharing and allocation, may limit the use of suboptimal grafts and necessitates rushed transplantation to achieve desirable post-transplantation outcomes. In an attempt to improve and prolong liver viability during storage, alternative preservation methods are under investigation. For instance, ex vivo machine perfusion systems aim to sustain and even improve viability by supporting hepatic function at warm temperatures, rather than simply slowing down deterioration by cooling. Here we describe a novel subzero preservation technique that combines ex vivo machine perfusion with cryoprotectants to facilitate long-term supercooled preservation. The technique improves the preservation of rat livers to prolong storage times as much as threefold, which is validated by successful long-term recipient survival after orthotopic transplantation. This protocol describes how to load rat livers with cryoprotectants to prevent both intracellular and extracellular ice formation and to protect against hypothermic injury. Cryoprotectants are loaded ex vivo using subnormothermic machine perfusion (SNMP), after which livers can be cooled to -6 °C without freezing and kept viable for up to 96 h. Cooling to a supercooled state is controlled, followed by 3 h of SNMP recovery and orthotopic liver transplantation.


Assuntos
Criopreservação/métodos , Crioprotetores/farmacologia , Transplante de Fígado/métodos , Fígado , Preservação de Órgãos , Animais , Ratos
18.
J Vis Exp ; (98)2015 Apr 27.
Artigo em Inglês | MEDLINE | ID: mdl-25938299

RESUMO

There is currently a severe shortage of liver grafts available for transplantation. Novel organ preservation techniques are needed to expand the pool of donor livers. Machine perfusion of donor liver grafts is an alternative to traditional cold storage of livers and holds much promise as a modality to expand the donor organ pool. We have recently described the potential benefit of subnormothermic machine perfusion of human livers. Machine perfused livers showed improving function and restoration of tissue ATP levels. Additionally, machine perfusion of liver grafts at subnormothermic temperatures allows for objective assessment of the functionality and suitability of a liver for transplantation. In these ways a great many livers that were previously discarded due to their suboptimal quality can be rescued via the restorative effects of machine perfusion and utilized for transplantation. Here we describe this technique of subnormothermic machine perfusion in detail. Human liver grafts allocated for research are perfused via the hepatic artery and portal vein with an acellular oxygenated perfusate at 21 °C.


Assuntos
Transplante de Fígado/métodos , Fígado/irrigação sanguínea , Preservação de Órgãos/métodos , Perfusão/instrumentação , Perfusão/métodos , Temperatura Baixa , Artéria Hepática , Humanos , Transplante de Fígado/instrumentação , Preservação de Órgãos/instrumentação , Veia Porta , Doadores de Tecidos
19.
Technology (Singap World Sci) ; 2(1): 13, 2014 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-25035864

RESUMO

Organ culture systems are instrumental as experimental whole-organ models of physiology and disease, as well as preservation modalities facilitating organ replacement therapies such as transplantation. Nevertheless, a coordinated system of machine perfusion components and integrated regulatory control has yet to be fully developed to achieve long-term maintenance of organ function ex vivo. Here we outline current strategies for organ culture, or organomatics, and how these systems can be regulated by means of computational algorithms, or organometrics, to achieve the organ culture platforms anticipated in modern-day biomedicine.

20.
Nat Med ; 20(7): 790-3, 2014 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-24973919

RESUMO

The realization of long-term human organ preservation will have groundbreaking effects on the current practice of transplantation. Herein we present a new technique based on subzero nonfreezing preservation and extracorporeal machine perfusion that allows transplantation of rat livers preserved for up to four days, thereby tripling the viable preservation duration.


Assuntos
Temperatura Baixa , Transplante de Fígado , Preservação de Órgãos , Taxa de Sobrevida , Animais , Ratos
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA