Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 420
Filtrar
Mais filtros

Tipo de documento
Intervalo de ano de publicação
1.
Eur Heart J ; 45(3): 161-177, 2024 Jan 14.
Artigo em Inglês | MEDLINE | ID: mdl-37638967

RESUMO

BACKGROUND AND AIMS: The European Union Medical Device Regulation 2017/745 challenges key stakeholders to follow transparent and rigorous approaches to the clinical evaluation of medical devices. The purpose of this study is a systematic evaluation of published clinical evidence underlying selected high-risk cardiovascular medical devices before and after market access in the European Union (CE-marking) between 2000 and 2021. METHODS: Pre-specified strategies were applied to identify published studies of prospective design evaluating 71 high-risk cardiovascular devices in seven different classes (bioresorbable coronary scaffolds, left atrial appendage occlusion devices, transcatheter aortic valve implantation systems, transcatheter mitral valve repair/replacement systems, surgical aortic and mitral heart valves, leadless pacemakers, subcutaneous implantable cardioverter-defibrillator). The search time span covered 20 years (2000-21). Details of study design, patient population, intervention(s), and primary outcome(s) were summarized and assessed with respect to timing of the corresponding CE-mark approval. RESULTS: At least one prospective clinical trial was identified for 70% (50/71) of the pre-specified devices. Overall, 473 reports of 308 prospectively designed studies (enrolling 97 886 individuals) were deemed eligible, including 81% (251/308) prospective non-randomized clinical trials (66 186 individuals) and 19% (57/308) randomized clinical trials (31 700 individuals). Pre-registration of the study protocol was available in 49% (150/308) studies, and 16% (48/308) had a peer-reviewed publicly available protocol. Device-related adverse events were evaluated in 82% (253/308) of studies. An outcome adjudication process was reported in 39% (120/308) of the studies. Sample size was larger for randomized in comparison to non-randomized trials (median of 304 vs. 100 individuals, P < .001). No randomized clinical trial published before CE-mark approval for any of the devices was identified. Non-randomized clinical trials were predominantly published after the corresponding CE-mark approval of the device under evaluation (89%, 224/251). Sample sizes were smaller for studies published before (median of 31 individuals) than after (median of 135 individuals) CE-mark approval (P < .001). Clinical trials with larger sample sizes (>50 individuals) and those with longer recruitment periods were more likely to be published after CE-mark approval, and were more frequent during the period 2016-21. CONCLUSIONS: The quantity and quality of publicly available data from prospective clinical investigations across selected categories of cardiovascular devices, before and after CE approval during the period 2000-21, were deemed insufficient. The majority of studies was non-randomized, with increased risk of bias, and performed in small populations without provision of power calculations, and none of the reviewed devices had randomized trial results published prior to CE-mark certification.


Assuntos
Sistema Cardiovascular , Substituição da Valva Aórtica Transcateter , Humanos , Coração , Próteses e Implantes , União Europeia
2.
Clin Sci (Lond) ; 138(6): 387-412, 2024 03 20.
Artigo em Inglês | MEDLINE | ID: mdl-38505993

RESUMO

Complement is an important component of innate immune defence against pathogens and crucial for efficient immune complex disposal. These core protective activities are dependent in large part on properly regulated complement-mediated inflammation. Dysregulated complement activation, often driven by persistence of activating triggers, is a cause of pathological inflammation in numerous diseases, including neurological diseases. Increasingly, this has become apparent not only in well-recognized neuroinflammatory diseases like multiple sclerosis but also in neurodegenerative and neuropsychiatric diseases where inflammation was previously either ignored or dismissed as a secondary event. There is now a large and rapidly growing body of evidence implicating complement in neurological diseases that cannot be comprehensively addressed in a brief review. Here, we will focus on neurodegenerative diseases, including not only the 'classical' neurodegenerative diseases such as Alzheimer's disease and Parkinson's disease, but also two other neurological diseases where neurodegeneration is a neglected feature and complement is implicated, namely, schizophrenia, a neurodevelopmental disorder with many mechanistic features of neurodegeneration, and multiple sclerosis, a demyelinating disorder where neurodegeneration is a major cause of progressive decline. We will discuss the evidence implicating complement as a driver of pathology in these diverse diseases and address briefly the potential and pitfalls of anti-complement drug therapy for neurodegenerative diseases.


Assuntos
Doença de Alzheimer , Esclerose Múltipla , Doenças Neurodegenerativas , Doença de Parkinson , Humanos , Inflamação , Esclerose Múltipla/tratamento farmacológico
3.
Eur Heart J ; 44(41): 4310-4320, 2023 11 01.
Artigo em Inglês | MEDLINE | ID: mdl-37632756

RESUMO

In October 2021, the European Society of Cardiology (ESC) and the European Association for Cardio-Thoracic Surgery (EACTS) jointly agreed to establish a Task Force (TF) to review recommendations of the 2018 ESC/EACTS Guidelines on myocardial revascularization as they apply to patients with left main (LM) disease with low-to-intermediate SYNTAX score (0-32). This followed the withdrawal of support by the EACTS in 2019 for the recommendations about the management of LM disease of the previous guideline. The TF was asked to review all new relevant data since the 2018 guidelines including updated aggregated data from the four randomized trials comparing percutaneous coronary intervention (PCI) with drug-eluting stents vs. coronary artery bypass grafting (CABG) in patients with LM disease. This document represents a summary of the work of the TF; suggested updated recommendations for the choice of revascularization modality in patients undergoing myocardial revascularization for LM disease are included. In stable patients with an indication for revascularization for LM disease, with coronary anatomy suitable for both procedures and a low predicted surgical mortality, the TF concludes that both treatment options are clinically reasonable based on patient preference, available expertise, and local operator volumes. The suggested recommendations for revascularization with CABG are Class I, Level of Evidence A. The recommendations for PCI are Class IIa, Level of Evidence A. The TF recognized several important gaps in knowledge related to revascularization in patients with LM disease and recognizes that aggregated data from the four randomized trials were still only large enough to exclude large differences in mortality.


Assuntos
Cardiologia , Doença da Artéria Coronariana , Intervenção Coronária Percutânea , Cirurgia Torácica , Humanos , Doença da Artéria Coronariana/cirurgia , Intervenção Coronária Percutânea/métodos , Ponte de Artéria Coronária/métodos , Resultado do Tratamento
4.
Am Heart J ; 260: 1-8, 2023 06.
Artigo em Inglês | MEDLINE | ID: mdl-36796573

RESUMO

BACKGROUND: Physiological assessment of intermediate coronary lesions to guide coronary revascularization is currently recommended by international guidelines. Vessel fractional flow reserve (vFFR) has emerged as a new approach to derive fractional flow reserve (FFR) from 3D-quantitative coronary angiography (3D-QCA) without the need for hyperemic agents or pressure wires. STUDY DESIGN AND OBJECTIVES: The FAST III is an investigator-initiated, open label, multicenter randomized trial comparing vFFR guided versus FFR guided coronary revascularization in approximately 2228 patients with intermediate coronary lesions (defined as 30%-80% stenosis by visual assessment or QCA). Intermediate lesions are physiologically assessed using on-line vFFR or FFR and treated if vFFR or FFR ≤0.80. The primary end point is a composite of all-cause death, any myocardial infarction, or any revascularization at 1-year post-randomization. Secondary end points include the individual components of the primary end point and cost-effectiveness will be investigated. CONCLUSIONS: FAST III is the first randomized trial to explore whether a vFFR guided revascularization strategy is non-inferior to an FFR guided strategy in terms of clinical outcomes at 1-year follow-up in patients with intermediate coronary artery lesions.


Assuntos
Doença da Artéria Coronariana , Estenose Coronária , Reserva Fracionada de Fluxo Miocárdico , Infarto do Miocárdio , Intervenção Coronária Percutânea , Humanos , Angiografia Coronária , Reserva Fracionada de Fluxo Miocárdico/fisiologia , Estudos Prospectivos , Seguimentos , Estenose Coronária/diagnóstico por imagem , Estenose Coronária/cirurgia , Resultado do Tratamento , Doença da Artéria Coronariana/diagnóstico , Doença da Artéria Coronariana/cirurgia
5.
Cytokine ; 162: 156103, 2023 02.
Artigo em Inglês | MEDLINE | ID: mdl-36463660

RESUMO

INTRODUCTION: Interleukin-10 (IL-10) is an anti-inflammatory cytokine with potent deactivating properties on macrophages and T cells; and plays an important role in atherosclerotic plaque maturation and rupture. A guanine (G) to adenine (A) substitution in the IL-10 gene at -1082 bp (rs1800896) has been associated with reduced in IL-10 production in vitro. Against this background, we tested the association of IL-10 -1082G/A with early or severe presentation of coronary artery disease (CAD) using a systematic review and updated meta-analysis of published association studies. MATERIALS AND METHODS: Relevant studies were identified following a comprehensive online search on PubMed, EMBASE, MEDLINE, Scopus, Cochrane library and Web of Science databases and stratified into two subgroups based on mode of CAD presentation: early or severe and non-severe. Study level odds ratios (ORs) and their 95% confidence intervals (CI) were pooled using random effects employing a Z test. RESULTS: A total of 24 studies were included for quantitative synthesis with a cumulative sample of 19,135 (11,143 cases / 7,992 controls). A significant association was derived for IL-10 -1082G/A and early or severe CAD via dominant, recessive, and allelic genetic model comparisons [OR 1.24 (95 % CI 1.02, 1.50), p = 0.03; OR 1.32 (95 % CI 1.03, 1.69), p = 0.03 and OR 1.18 (95 % CI 1.02, 1.36), p = 0.02 respectively]. In contrast, no significant association was seen for the pooled group or non-severe CAD subgroup (p = NS). Sensitivity analysis showed consistent results. CONCLUSIONS: IL-10 -1082G/A appears to be associated with early or severe presentation of CAD. Further studies are warranted to confirm this association.


Assuntos
Doença da Artéria Coronariana , Humanos , Doença da Artéria Coronariana/genética , Interleucina-10/genética , Polimorfismo de Nucleotídeo Único/genética , Predisposição Genética para Doença , Expressão Gênica
6.
Nitric Oxide ; 138-139: 85-95, 2023 09 01.
Artigo em Inglês | MEDLINE | ID: mdl-37451608

RESUMO

INTRODUCTION: Several published studies have reported an association between the Glu298Asp polymorphism (rs1799983), residing in the endothelial nitric oxide synthase (NOS3) gene, and lower levels of circulating nitric oxide, as well as an increased risk of coronary artery disease (CAD). However, association status of this genetic variant with acute coronary syndrome (ACS) or premature CAD (PCAD) is still unclear. Against this background, we conducted a systematic review and study level meta-analysis to assess the association of the NOS3 Glu298Asp polymorphism with ACS or PCAD. MATERIALS AND METHODS: A comprehensive online search to identify relevant studies was performed on several databases including PubMed, EMBASE, MEDLINE, Scopus, Cochrane library and Web of Science. The identified studies were stratified into two ancestral subgroups: 'European ancestry' and 'All other ancestries combined'. Study level odds ratios (ORs) and their 95% confidence intervals (CI) were pooled using random/fixed effects employing a Z test. RESULTS: Out of a total of 195 distinct records identified through online search, 37 articles with 39 different studies, with a total sample size of 27,441 (11,516 cases/15,925 controls) were included for quantitative synthesis. Pooled results suggested significant associations of the NOS3 Glu298Asp polymorphism with ACS or PCAD through dominant as well as allelic genetic models (p ≤ 0.002), primarily driven by the 'All other ancestries combined' subgroup. The 'All other ancestries combined' subgroup demonstrated an additional risk of 36% for ACS or PCAD, through both dominant and allelic genetic models (OR = 1.36, 95%CI = 1.13, 1.63, p = 0.001 and OR = 1.36, 95%CI = 1.14, 1.61, p = 0.0005 respectively). On the other hand, the 'European ancestry' subgroup did not show any significant associations. Sensitivity analysis and a sub-analysis for the myocardial infarction endpoint further supported these observed associations. CONCLUSIONS: This meta-analysis indicates towards an association between the NOS3 Glu298Asp polymorphism and ACS or PCAD, predominantly driven by 'All other ancestries combined' subgroup. In contrast, the 'European ancestry' subgroup did not demonstrate any significant association. Further large-scale investigations are required to confirm our derived results.


Assuntos
Síndrome Coronariana Aguda , Doença da Artéria Coronariana , Óxido Nítrico Sintase Tipo III , Humanos , Síndrome Coronariana Aguda/genética , Doença da Artéria Coronariana/genética , Predisposição Genética para Doença , Genótipo , Óxido Nítrico Sintase/genética , Óxido Nítrico Sintase Tipo III/genética , Polimorfismo de Nucleotídeo Único
7.
Catheter Cardiovasc Interv ; 99(3): 754-762, 2022 02.
Artigo em Inglês | MEDLINE | ID: mdl-34791755

RESUMO

OBJECTIVES: We investigated the clinical efficacy of a paclitaxel-coated balloon (PCB) with a novel matrix coating and reduced drug concentration in comparison with a widely used PCB with iopromide excipient. METHODS: We prospectively enrolled patients with restenosis in drug-eluting stents. All patients were treated with a novel low-dose PCB with citrate-based excipient (Agent PCB). Angiographic follow-up was scheduled at 6-8 months. Outcomes were compared against those of patients treated with iopromide excipient PCB (SeQuent Please PCB) enrolled in a trial with identical inclusion and exclusion criteria. The primary endpoint was percent diameter stenosis (%DS) at follow-up angiography. The primary hypothesis was that the investigational device would be non-inferior to the control device (ClinicalTrials.gov Identifier: NCT02367495). RESULTS: One hundred twenty-five patients with 151 lesions were enrolled. Mean age was 68.1 ± 10.2 years, 40.8% had diabetes mellitus and 80.1% had focal morphology in-stent restenosis. Follow-up angiography data at 6-8 months was available for 102 (81.6%) patients. The Agent PCB was non-inferior to the SeQuent Please PCB in terms of the primary endpoint (38.9 ± 17.5 vs. 38.1 ± 21.5%; p non-inferiority  = 0.0056). Late lumen loss was also comparable between the groups (0.35 ± 0.55 vs. 0.37 ± 0.59; p = 0.71). There was no difference between the groups in the incidence of TLR (27.7% vs. 22.1%; p = 0.31), death or myocardial infarction (4.2% vs. 4.4%; p = 0.92) or target lesion thrombosis (1.0% vs. 0.7%; p = 0.93). CONCLUSION: In patients with DES restenosis, angioplasty with a novel PCB with citrate-based excipient was non-inferior to PCB with iopromide excipient in terms of angiographic outcome.


Assuntos
Angioplastia Coronária com Balão , Fármacos Cardiovasculares , Reestenose Coronária , Stents Farmacológicos , Idoso , Angioplastia Coronária com Balão/efeitos adversos , Fármacos Cardiovasculares/efeitos adversos , Constrição Patológica/induzido quimicamente , Constrição Patológica/complicações , Angiografia Coronária/efeitos adversos , Reestenose Coronária/diagnóstico por imagem , Reestenose Coronária/etiologia , Reestenose Coronária/terapia , Stents Farmacológicos/efeitos adversos , Humanos , Pessoa de Meia-Idade , Paclitaxel/efeitos adversos , Estudos Prospectivos , Stents/efeitos adversos , Resultado do Tratamento
8.
Eur Heart J ; 42(4): 308-319, 2021 01 21.
Artigo em Inglês | MEDLINE | ID: mdl-33284979

RESUMO

AIMS: After percutaneous coronary intervention (PCI) with second-generation drug-eluting stent (DES), whether short dual antiplatelet therapy (DAPT) followed by single antiplatelet therapy (SAPT) with a P2Y12 receptor inhibitor confers benefits compared with prolonged DAPT is unclear. METHODS AND RESULTS: Multiple electronic databases, including PubMed, Scopus, Web of Sciences, Ovid, and ScienceDirect, were searched to identify randomized clinical trials comparing ≤3 months of DAPT followed by P2Y12 inhibitor SAPT vs. 12 months of DAPT after PCI with second-generation DES implantation. The primary and co-primary outcomes of interest were major bleeding and stent thrombosis 1 year after randomization. Summary hazard ratios (HRs) and 95% confidence intervals (CIs) were estimated by fixed-effect and random-effects models. Multiple sensitivity analyses including random-effects models 95% CI adjustment were applied. A sensitivity analysis comparing trials using P2Y12 inhibitor SAPT with those using aspirin SAPT was performed. A total of five randomized clinical trials (32 145 patients) were available. Major bleeding was significantly lower in the patients assigned to short DAPT followed by P2Y12 inhibitor SAPT compared with those assigned to 12-month DAPT (random-effects model: HR 0.63, 95% 0.45-0.86). No significant differences between groups were observed in terms of stent thrombosis (random-effects model: HR 1.19, 95% CI 0.86-1.65) and the secondary endpoints of all-cause death (random-effects model: HR 0.85, 95% CI 0.70-1.03), myocardial infarction (random-effects model: HR 1.05, 95% CI 0.89-1.23), and stroke (random-effects model: HR 1.08, 95% CI 0.68-1.74). Sensitivity analyses showed overall consistent results. By comparing trials testing ≤3 months of DAPT followed by P2Y12 inhibitor SAPT vs. 12 months of DAPT with trials testing ≤3 months of DAPT followed by aspirin SAPT vs. 12-month of DAPT, there was no treatment-by-subgroup interaction for each endpoint. By combining all these trials, regardless of the type of SAPT, short DAPT was associated with lower major bleeding (random-effects model: HR 0.63, 95% CI 0.48-0.83) and no differences in stent thrombosis, all-cause death, myocardial infarction, and stroke were observed between regimens. CONCLUSION: After second-generation DES implantation, 1-3 months of DAPT followed by P2Y12 inhibitor SAPT is associated with lower major bleeding and similar stent thrombosis, all-cause death, myocardial infarction, and stroke compared with prolonged DAPT. Whether P2Y12 inhibitor SAPT is preferable to aspirin SAPT needs further investigation.


Assuntos
Stents Farmacológicos , Intervenção Coronária Percutânea , Quimioterapia Combinada , Humanos , Inibidores da Agregação Plaquetária/uso terapêutico , Antagonistas do Receptor Purinérgico P2Y , Ensaios Clínicos Controlados Aleatórios como Assunto , Resultado do Tratamento
9.
Eur Heart J ; 42(16): 1545-1553, 2021 04 21.
Artigo em Inglês | MEDLINE | ID: mdl-33507260

RESUMO

Patent foramen ovale (PFO) is implicated in the pathogenesis of a number of medical conditions but to date only one official position paper related to left circulation thromboembolism has been published. This interdisciplinary paper, prepared with the involvement of eight European scientific societies, reviews the available evidence and proposes a rationale for decision making for other PFO-related clinical conditions. In order to guarantee a strict evidence-based process, we used a modified grading of recommendations, assessment, development, and evaluation (GRADE) methodology. A critical qualitative and quantitative evaluation of diagnostic and therapeutic procedures was performed, including assessment of the risk/benefit ratio. The level of evidence and the strength of the position statements were weighed and graded according to predefined scales. Despite being based on limited and observational or low-certainty randomised data, a number of position statements were made to frame PFO management in different clinical settings, along with suggestions for new research avenues. This interdisciplinary position paper, recognising the low or very low certainty of existing evidence, provides the first approach to several PFO-related clinical scenarios beyond left circulation thromboembolism and strongly stresses the need for fresh high-quality evidence on these topics.


Assuntos
Doença da Descompressão , Forame Oval Patente , Transtornos de Enxaqueca , Tromboembolia , Doença da Descompressão/terapia , Forame Oval Patente/complicações , Forame Oval Patente/terapia , Humanos , Síndrome , Tromboembolia/etiologia , Tromboembolia/prevenção & controle
10.
Environ Manage ; 69(3): 612-625, 2022 03.
Artigo em Inglês | MEDLINE | ID: mdl-35079882

RESUMO

Coral reef metabolism measurements have been used by scientists for decades to track reef responses to the globe's changing carbon budget and project shifts in reef function. Here, we propose that metabolism measurement tools and methods could also be used to monitor reef ecosystem change in response to coral restoration. This review paper provides a general introduction to net ecosystem metabolism and carbon chemistry for coral reef ecosystems, followed by a review of five metabolism monitoring methods with potential for application to coral reef restoration monitoring. Selected methodologies included those with measurement scales appropriate to assess outplant arrays and whole reef ecosystem outcomes associated with restoration interventions. Subsequently we discuss how water column and CO2 chemistry could be used to address coral restoration monitoring research gaps and scale up from biological, colony-level metrics to ecosystem-scale function and performance assessments. Such function-based measurements could potentially be used to inform several goal-based monitoring objectives highlighted in the Coral Reef Restoration Monitoring Guide. Lastly, this review discusses important methodological factors, such as scale, reef type, and flow environment, that should be considered when determining which metabolism monitoring technique would be most appropriate for a reef restoration project.


Assuntos
Antozoários , Animais , Carbono , Recifes de Corais , Ecossistema
11.
Catheter Cardiovasc Interv ; 98(5): 857-862, 2021 11 01.
Artigo em Inglês | MEDLINE | ID: mdl-32845090

RESUMO

OBJECTIVES: The present study aims to analyze the angiographic anti-restenotic performance of durable polymer everolimus-eluting stents (EES) for the treatment of in-stent restenosis (ISR) in daily practice. BACKGROUND: Randomized data is available supporting the use of drug-coated balloons and drug-eluting stents for the treatment of ISR; however, additional real-world data including angiographic follow-up is needed. METHODS: Patients who underwent EES-implantation for the treatment of drug-eluting stent ISR and attended for a 6-8 months angiographic surveillance were analyzed. Off-line assessment of the angiograms was conducted at a central quantitative coronary angiographic core laboratory. RESULTS: A total of 426 patients with ISR were treated with EES and had undergone angiographic follow-up. The mean age was 66.8 ± 9.9 years and 27.5% suffered from diabetes. A total of 459 lesions were treated. The diameter stenosis decreased from 64.3 ± 19.1% (preprocedural) to 12.0 ± 6.4% (postprocedural). At 6-8 months angiographic follow-up, the in-segment diameter stenosis was 38.3 ± 21.7% and the in-stent late luminal loss was 0.54 ± 0.74 mm in the treated area analysis. The rate of recurrent binary restenosis was 25.7%. CONCLUSIONS: In the setting of ISR, the angiographic anti-restenotic efficacy of stenting with EES is comparable to that observed in randomized clinical trials and less favorable than its performance in patients undergoing stenting for de novo disease.


Assuntos
Angioplastia Coronária com Balão , Reestenose Coronária , Stents Farmacológicos , Intervenção Coronária Percutânea , Idoso , Constrição Patológica , Angiografia Coronária , Reestenose Coronária/diagnóstico por imagem , Reestenose Coronária/etiologia , Everolimo , Humanos , Pessoa de Meia-Idade , Intervenção Coronária Percutânea/efeitos adversos , Estudos Prospectivos , Desenho de Prótese , Stents , Resultado do Tratamento
12.
Inflamm Res ; 70(10-12): 1075-1087, 2021 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-34595552

RESUMO

INTRODUCTION: Circulating IL-6 levels and at least one polymorphic form of IL6 gene (IL6 -174 G/C, rs1800795) have been shown to be independently associated with coronary artery disease (CAD) by several investigators. Despite more than 12 published meta-analyses on this subject, association of -174 G/C with CAD, especially amongst distinct ancestral population groups remain unclear. We, therefore, conducted a systematic review and an updated meta-analysis to comprehensively ascertain the association of IL6 -174 G/C with CAD and circulating IL-6 levels. MATERIALS AND METHODS: Relevant case-control/cohort studies investigating association of -174 G/C with CAD and circulating IL-6 levels were identified following a comprehensive online search. Association status for CAD was determined for the pooled sample, as well as separately for major ancestral subgroups. Association status for circulating IL-6 levels was assessed for the pooled sample, as well as separately for CAD cases and CAD free controls. Study-level odds ratios (OR) and 95% confidence intervals (CI) were pooled using random/fixed-effects model. RESULTS: Quantitative synthesis for the CAD endpoint was performed using 55 separate qualifying studies with a collective sample size of 51,213 (19,160 cases/32,053 controls). Pooled association of -174 G/C with CAD was found to be statistically significant through dominant (OR 1.15; 95% CI 1.05-1.25, p = 0.002) as well as allelic genetic model comparisons (OR 1.13, 95% CI 1.06-1.21, p = 0.0003). This effect was largely driven by Asian and Asian Indian ancestral subgroups, which also showed significant association with CAD in both genetic model comparisons (OR range 1.29-1.53, p value range ≤ 0.02). Other ancestral subgroups failed to show any meaningful association. Circulating IL-6 levels were found to be significantly higher amongst the 'C' allele carriers in the pooled sample (Standard mean difference, SMD 0.11, 95% CI 0.01-0.22 pg/ml, p = 0.009) as well as in the CAD free control subgroup (SMD 0.10, 95% CI 0.02-0.17 pg/ml, p = 0.009), though not in the CAD case subgroup (SMD 0.17, 95% CI = - 0.02 to 0.37, p = 0.12). CONCLUSIONS: The present systematic review and meta-analysis demonstrate an overall association between IL6 -174 G/C polymorphism and CAD, which seems to be mainly driven by Asian and Asian Indian ancestral subgroups. Upregulation of plasma IL-6 levels in the 'C' allele carriers seems to be at least partly responsible for this observed association. This warrants further investigations with large, structured case-control studies especially amongst Asian and Asian Indian ancestral groups.


Assuntos
Doença da Artéria Coronariana/genética , Interleucina-6/genética , Doença da Artéria Coronariana/sangue , Predisposição Genética para Doença , Humanos , Interleucina-6/sangue , Polimorfismo de Nucleotídeo Único
13.
Eur Heart J ; 41(27): 2589-2596, 2020 07 14.
Artigo em Inglês | MEDLINE | ID: mdl-32484542

RESUMO

The new European Union (EU) law governing the regulatory approval of medical devices that entered into force in May 2017 will now take effect from 26 May 2021. Here, we consider how it will change daily practice for cardiologists, cardiac surgeons, and healthcare professionals. Clinical evidence for any high-risk device must be reported by the manufacturer in a Summary of Safety and Clinical Performance (SSCP) that will be publicly available in the European Union Database on Medical Devices (Eudamed) maintained by the European Commission; this will facilitate evidence-based choices of which devices to recommend. Hospitals must record all device implantations, and each high-risk device will be trackable by Unique Device Identification (UDI). Important new roles are envisaged for clinicians, scientists, and engineers in EU Expert Panels-in particular to scrutinize clinical data submitted by manufacturers for certain high-risk devices and the evaluations of that data made by notified bodies. They will advise manufacturers on the design of their clinical studies and recommend to regulators when new technical specifications or guidance are needed. Physicians should support post-market surveillance by reporting adverse events and by contributing to comprehensive medical device registries. A second law on In Vitro Diagnostic Medical Devices will take effect from 2022. We encourage all healthcare professionals to contribute proactively to these new systems, in order to enhance the efficacy and safety of high-risk devices and to promote equitable access to effective innovations. The European Society of Cardiology will continue to advise EU regulators on appropriate clinical evaluation of high-risk devices.


Assuntos
Cardiologia , União Europeia , Prática Clínica Baseada em Evidências , Humanos
14.
Circulation ; 139(3): 325-333, 2019 01 15.
Artigo em Inglês | MEDLINE | ID: mdl-30586724

RESUMO

BACKGROUND: New-generation drug-eluting stents offer the potential for enhanced late outcomes in comparison with early generation drug-eluting stents. However, assessment of extended long-term outcomes for these devices is lacking, especially regarding the comparison between new-generation drug-eluting stents with biodegradable or permanent polymers. The aim of this study is to compare the efficacy and safety of biodegradable polymer-based sirolimus-eluting stents (BP-SES; Yukon Choice PC) versus permanent polymer-based everolimus-eluting stents (PP-EES; Xience) versus early generation permanent polymer-based sirolimus-eluting stents (PP-SES; Cypher) at 10-year follow-up. METHODS: Overall, 2603 patients were randomized to treatment with BP-SES (n=1299), PP-EES (n=652), or PP-SES (n=652). The primary end point of this analysis was major adverse cardiac event, the composite of death, myocardial infarction, or target lesion revascularization. The main secondary end point of interest was definite/probable stent thrombosis. Follow-up at 10 years was available in 83% of the study patients. RESULTS: The 10-year incidence of major adverse cardiac event (BP-SES 47.7% versus PP-EES 46.0% versus PP-SES 54.9%, P=0.003) and mortality (BP-SES 31.8% versus PP-EES 30.3% versus PP-SES 37.2%, P=0.02) was different among the groups. Definite/probable stent thrombosis was not significantly different among the groups (BP-SES 1.8% versus PP-EES 2.5% versus PP-SES 3.7%, P=0.09). Definite stent thrombosis was significantly different among the groups (BP-SES 1.1% versus PP-EES 0.8% versus PP-SES 2.4%, P=0.03). There were no significant differences between BP-SES and PP-EES. CONCLUSIONS: In this unique long-term outcome analysis, BP-SES and PP-EES showed comparable clinical outcomes out to 10 years. PP-SES had higher rates of major adverse cardiac events and definite stent thrombosis. CLINICAL TRIAL REGISTRATION: URL: https://www.clinicaltrials.gov . Unique identifier: NCT00598676.


Assuntos
Implantes Absorvíveis , Fármacos Cardiovasculares/administração & dosagem , Doença da Artéria Coronariana/terapia , Estenose Coronária/terapia , Stents Farmacológicos , Intervenção Coronária Percutânea/instrumentação , Polímeros/química , Sirolimo/administração & dosagem , Idoso , Fármacos Cardiovasculares/efeitos adversos , Angiografia Coronária , Doença da Artéria Coronariana/diagnóstico por imagem , Doença da Artéria Coronariana/mortalidade , Estenose Coronária/diagnóstico por imagem , Estenose Coronária/mortalidade , Trombose Coronária/etiologia , Trombose Coronária/mortalidade , Everolimo/administração & dosagem , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Infarto do Miocárdio/etiologia , Infarto do Miocárdio/mortalidade , Intervenção Coronária Percutânea/efeitos adversos , Intervenção Coronária Percutânea/mortalidade , Desenho de Prótese , Medição de Risco , Fatores de Risco , Sirolimo/efeitos adversos , Fatores de Tempo , Resultado do Tratamento
15.
Circulation ; 140(3): 240-261, 2019 07 16.
Artigo em Inglês | MEDLINE | ID: mdl-31116032

RESUMO

Identification and management of patients at high bleeding risk undergoing percutaneous coronary intervention are of major importance, but a lack of standardization in defining this population limits trial design, data interpretation, and clinical decision-making. The Academic Research Consortium for High Bleeding Risk (ARC-HBR) is a collaboration among leading research organizations, regulatory authorities, and physician-scientists from the United States, Asia, and Europe focusing on percutaneous coronary intervention-related bleeding. Two meetings of the 31-member consortium were held in Washington, DC, in April 2018 and in Paris, France, in October 2018. These meetings were organized by the Cardiovascular European Research Center on behalf of the ARC-HBR group and included representatives of the US Food and Drug Administration and the Japanese Pharmaceuticals and Medical Devices Agency, as well as observers from the pharmaceutical and medical device industries. A consensus definition of patients at high bleeding risk was developed that was based on review of the available evidence. The definition is intended to provide consistency in defining this population for clinical trials and to complement clinical decision-making and regulatory review. The proposed ARC-HBR consensus document represents the first pragmatic approach to a consistent definition of high bleeding risk in clinical trials evaluating the safety and effectiveness of devices and drug regimens for patients undergoing percutaneous coronary intervention.


Assuntos
Congressos como Assunto , Consenso , Hemorragia/diagnóstico , Hemorragia/etiologia , Intervenção Coronária Percutânea/efeitos adversos , Anticoagulantes/administração & dosagem , Anticoagulantes/efeitos adversos , Congressos como Assunto/tendências , District of Columbia , Hemorragia/prevenção & controle , Humanos , Paris , Intervenção Coronária Percutânea/tendências , Medição de Risco/métodos
16.
Int J Cancer ; 147(10): 2891-2901, 2020 11 15.
Artigo em Inglês | MEDLINE | ID: mdl-32700762

RESUMO

Antibodies targeting the human epidermal growth factor receptor (EGFR) are used for the treatment of RAS wild-type metastatic colorectal cancer. A significant proportion of patients remains unresponsive to this therapy. Here, we performed a reverse-phase protein array-based (phospho)protein analysis of 63 KRAS, NRAS, BRAF and PIK3CA wild-type metastatic CRC tumours. Responses of tumours to anti-EGFR therapy with cetuximab were recorded in patient-derived xenograft (PDX) models. Unsupervised hierarchical clustering of pretreatment tumour tissue identified three clusters, of which Cluster C3 was exclusively composed of responders. Clusters C1 and C2 exhibited mixed responses. None of the three protein clusters exhibited a significant correlation with transcriptome-based subtypes. Analysis of protein signatures across all PDXs identified 14 markers that discriminated cetuximab-sensitive and cetuximab-resistant tumours: PDK1 (S241), caspase-8, Shc (Y317), Stat3 (Y705), p27, GSK-3ß (S9), HER3, PKC-α (S657), EGFR (Y1068), Akt (S473), S6 ribosomal protein (S240/244), HER3 (Y1289), NF-κB-p65 (S536) and Gab-1 (Y627). Least absolute shrinkage and selection operator and binominal logistic regression analysis delivered refined protein signatures for predicting response to cetuximab. (Phospo-)protein analysis of matched pretreated and posttreated models furthermore showed significant reduction of Gab-1 (Y627) and GSK-3ß (S9) exclusively in responding models, suggesting novel targets for treatment.


Assuntos
Cetuximab/administração & dosagem , Neoplasias Colorretais/tratamento farmacológico , Neoplasias Hepáticas/tratamento farmacológico , Neoplasias Hepáticas/secundário , Fosfoproteínas/metabolismo , Proteômica/métodos , Animais , Proliferação de Células/efeitos dos fármacos , Cetuximab/farmacologia , Classe I de Fosfatidilinositol 3-Quinases/genética , Análise por Conglomerados , Neoplasias Colorretais/genética , Neoplasias Colorretais/metabolismo , Feminino , GTP Fosfo-Hidrolases/genética , Humanos , Neoplasias Hepáticas/genética , Neoplasias Hepáticas/metabolismo , Masculino , Proteínas de Membrana/genética , Camundongos , Fosfoproteínas/efeitos dos fármacos , Proteínas Proto-Oncogênicas B-raf/genética , Proteínas Proto-Oncogênicas p21(ras)/genética , Aprendizado de Máquina não Supervisionado , Ensaios Antitumorais Modelo de Xenoenxerto
17.
Lancet ; 393(10190): 2503-2510, 2019 06 22.
Artigo em Inglês | MEDLINE | ID: mdl-31056295

RESUMO

BACKGROUND: New-generation drug-eluting stents (DES) have mostly been investigated in head-to-head non-inferiority trials against early-generation DES and have typically shown similar efficacy and superior safety. How the safety profile of new-generation DES compares with that of bare-metal stents (BMS) is less clear. METHODS: We did an individual patient data meta-analysis of randomised clinical trials to compare outcomes after implantation of new-generation DES or BMS among patients undergoing percutaneous coronary intervention. The primary outcome was the composite of cardiac death or myocardial infarction. Data were pooled in a one-stage random-effects meta-analysis and examined at maximum follow-up and a 1-year landmark. Risk estimates are reported as hazard ratios (HRs) with 95% CIs. This study is registered in PROSPERO, number CRD42017060520. FINDINGS: We obtained individual data for 26 616 patients in 20 randomised trials. Mean follow-up was 3·2 (SD 1·8) years. The risk of the primary outcome was reduced in DES recipients compared with BMS recipients (HR 0·84, 95% CI 0·78-0·90, p<0·001) owing to a reduced risk of myocardial infarction (0·79, 0·71-0·88, p<0·001) and a possible slight but non-significant cardiac mortality benefit (0·89, 0·78-1·01, p=0·075). All-cause death was unaffected (HR with DES 0·96, 95% CI 0·88-1·05, p=0·358), but risk was lowered for definite stent thrombosis (0·63, 0·50-0·80, p<0·001) and target-vessel revascularisation (0·55, 0·50-0·60, p<0·001). We saw a time-dependent treatment effect, with DES being associated with lower risk of the primary outcome than BMS up to 1 year after placement. While the effect was maintained in the longer term, there was no further divergence from BMS after 1 year. INTERPRETATION: The performance of new-generation DES in the first year after implantation means that BMS should no longer be considered the gold standard for safety. Further development of DES technology should target improvements in clinical outcomes beyond 1 year. FUNDING: Bern University Hospital.


Assuntos
Infarto do Miocárdio/cirurgia , Intervenção Coronária Percutânea/instrumentação , Stents/efeitos adversos , Idoso , Idoso de 80 Anos ou mais , Stents Farmacológicos/efeitos adversos , Estudos de Equivalência como Asunto , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Infarto do Miocárdio/mortalidade , Razão de Chances , Intervenção Coronária Percutânea/mortalidade , Desenho de Prótese , Ensaios Clínicos Controlados Aleatórios como Assunto , Medição de Risco , Resultado do Tratamento
18.
Am Heart J ; 219: 109-116, 2020 01.
Artigo em Inglês | MEDLINE | ID: mdl-31756624

RESUMO

BACKGROUND: Randomized trials did not consistently support superiority of ticagrelor, as monotherapy or in combination with aspirin, in terms of efficacy or safety, in patients with atherosclerotic artery disease. METHODS: Medline, EMBASE, the Cochrane Central Register of Controlled Trials, and scientific session abstracts were searched for trials of patients with coronary or peripheral artery disease (with >1,000 participants and a follow-up ≥3 months) randomly assigned to ticagrelor-based or conventional antiplatelet therapies. Trial-level hazard ratios (HRs) were pooled using a fixed- or random-effect model (in case of significant heterogeneity) with the inverse variance weighting. The primary outcome was all-cause mortality. Other outcomes were myocardial infarction (MI), stroke, and major bleeding. RESULTS: Overall 77,489 patients received either ticagrelor-based (n = 38,721) or conventional antiplatelet regimens (n = 38,768) in 6 trials. The primary outcome occurred in 4.5% of patients treated with experimental therapy and 4.9% of patients treated with control therapy (HR = 0.91, 95% CI 0.81-1.01; P = .07). Overall, patients treated with ticagrelor-based versus conventional antiplatelet regimens showed no significant difference in terms of all-cause death, MI, stroke, or major bleeding after 20 months. However, in trials of patients with coronary artery disease as primary diagnosis, the risk for all-cause death (HR = 0.84 [0.77-0.91], P < .001) and MI (HR = 0.87 [0.80-0.94], P = .007) was significantly reduced by experimental therapy. CONCLUSIONS: In patients with atherosclerotic artery disease, the benefit of ticagrelor-based therapies was confined to patients treated for coronary artery disease. The drug significantly reduced the risk for all-cause death and MI without excess risk of bleeding in these patients. In consideration of limitations of subgroup analyses, these results need further validation.


Assuntos
Aterosclerose/tratamento farmacológico , Doença da Artéria Coronariana/tratamento farmacológico , Inibidores da Agregação Plaquetária/uso terapêutico , Ensaios Clínicos Controlados Aleatórios como Assunto , Ticagrelor/uso terapêutico , Aterosclerose/mortalidade , Causas de Morte , Doença da Artéria Coronariana/mortalidade , Hemorragia/epidemiologia , Humanos , Infarto do Miocárdio/epidemiologia , Infarto do Miocárdio/prevenção & controle , Inibidores da Agregação Plaquetária/efeitos adversos , Sensibilidade e Especificidade , Acidente Vascular Cerebral/epidemiologia , Ticagrelor/efeitos adversos
19.
Catheter Cardiovasc Interv ; 96(5): 1008-1015, 2020 11.
Artigo em Inglês | MEDLINE | ID: mdl-31789486

RESUMO

BACKGROUND: Whether there exist differences concerning clinical outcomes between patients presenting with early versus late DES-ISR undergoing treatment with drug-coated balloons (DCB) remains a scientific knowledge gap. METHODS: This is a pooled analysis including patients with DES-ISR assigned to treatment with DCB in the setting of the ISAR DESIRE 3 and 4 trials. Clinical outcomes were evaluated according to time of occurrence of ISR after DES implantation, in patients presenting with early (≤12 months) versus late DES-ISR (>12 months) undergoing treatment with DCB. The primary endpoint of this analysis was major adverse cardiac event (MACE), defined as the combined incidence of death, myocardial infarction and target lesion revascularization (TLR) at 12 months after DCB treatment. Secondary endpoints included the incidence of death, myocardial infarction, TLR and target lesion thrombosis at 12 months after DCB treatment. RESULTS: This analysis included 352 patients, 199 patients presented with early-ISR, 153 patients with late-ISR. Concerning the primary endpoint, patients with early-DES-ISR as compared those with late-DES-ISR showed significant higher risk (25.9% vs. 17.0%; p = .04). In a multivariate analysis including diabetic status, clinical presentation, previous coronary bypass graft and diameter stenosis after DCB-treatment, the adjusted hazard ratio showed significant higher risk for MACE of early-DES-ISR as compared to late-DES-ISR (HRadj = 1.8, [95% CI = 1.1-3.0], p = .02). CONCLUSION: Clinical outcome at 12 months after treatment of DES-ISR with DCB, showed significant higher clinical event rates in patients presenting with early DES restenosis, as compared with patients presenting with late DES restenosis.


Assuntos
Angioplastia Coronária com Balão/instrumentação , Materiais Revestidos Biocompatíveis , Doença da Artéria Coronariana/terapia , Reestenose Coronária/terapia , Stents Farmacológicos , Intervenção Coronária Percutânea/instrumentação , Idoso , Angioplastia Coronária com Balão/efeitos adversos , Angioplastia Coronária com Balão/mortalidade , Doença da Artéria Coronariana/diagnóstico por imagem , Doença da Artéria Coronariana/mortalidade , Reestenose Coronária/diagnóstico por imagem , Reestenose Coronária/etiologia , Reestenose Coronária/mortalidade , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Intervenção Coronária Percutânea/efeitos adversos , Intervenção Coronária Percutânea/mortalidade , Ensaios Clínicos Controlados Aleatórios como Assunto , Medição de Risco , Fatores de Risco , Fatores de Tempo , Resultado do Tratamento
20.
J Interv Cardiol ; 2020: 9740938, 2020.
Artigo em Inglês | MEDLINE | ID: mdl-33223974

RESUMO

OBJECTIVES: To analyze the impact of different techniques of lesion preparation of severely calcified coronary bifurcation lesions. BACKGROUND: The impact of different techniques of lesion preparation of severely calcified coronary bifurcation lesions is poorly investigated. METHODS: We performed an as-treated analysis on 47 calcified bifurcation lesions treated with scoring/cutting balloons (SCB) and 68 lesions treated with rotational atherectomy (RA) in the PREPARE-CALC trial. Compromised side branch (SB) as assessed in the final angiogram was the primary outcome measure and was defined as any significant stenosis, dissection, or thrombolysis in myocardial infarction flow <3. RESULTS: True bifurcation lesions were present in 49% vs. 43% of cases in the SCB and RA groups, respectively. After stent implantation, SB balloon dilatation was necessary in around one-third of cases (36% vs. 38%; p = 0.82), and a two-stent technique was performed in 21.3% vs. 25% (p = 0.75). At the end of the procedure, the SB remained compromised in 15 lesions (32%) in the SCB group and 5 lesions (7%) in the RA group (p = 0.001). Large coronary dissections were more frequently observed in the SCB group (13% vs. 2%; p = 0.02). Postprocedural levels of cardiac biomarkers were significantly higher in patients with a compromised SB at the end of the procedure. CONCLUSIONS: In the PREPARE-CALC trial, side branch compromise was more frequently observed after lesion preparation with SCB as compared with RA. Consequently, in calcified bifurcation lesions, an upfront debulking with an RA-based strategy might optimize the result in the side branch.


Assuntos
Angioplastia Coronária com Balão , Aterectomia Coronária , Angiografia Coronária/métodos , Doença da Artéria Coronariana , Vasos Coronários , Complicações Pós-Operatórias , Calcificação Vascular , Idoso , Angioplastia Coronária com Balão/efeitos adversos , Angioplastia Coronária com Balão/métodos , Angioplastia Coronária com Balão/estatística & dados numéricos , Aterectomia Coronária/efeitos adversos , Aterectomia Coronária/métodos , Aterectomia Coronária/estatística & dados numéricos , Doença da Artéria Coronariana/patologia , Doença da Artéria Coronariana/cirurgia , Vasos Coronários/diagnóstico por imagem , Vasos Coronários/patologia , Vasos Coronários/cirurgia , Feminino , Humanos , Masculino , Avaliação de Processos e Resultados em Cuidados de Saúde , Complicações Pós-Operatórias/etiologia , Complicações Pós-Operatórias/prevenção & controle , Risco Ajustado/métodos , Calcificação Vascular/diagnóstico , Calcificação Vascular/cirurgia
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA