Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 148
Filtrar
Mais filtros

Base de dados
País/Região como assunto
Tipo de documento
Intervalo de ano de publicação
1.
Surg Endosc ; 38(6): 3212-3222, 2024 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-38637339

RESUMO

INTRODUCTION: Intraoperative indocyanine green fluorescence angiography (ICGFA) aims to reduce colorectal anastomotic complications. However, signal interpretation is inconsistent and confounded by patient physiology and system behaviours. Here, we demonstrate a proof of concept of a novel clinical and computational method for patient calibrated quantitative ICGFA (QICGFA) bowel transection recommendation. METHODS: Patients undergoing elective colorectal resection had colonic ICGFA both immediately after operative commencement prior to any dissection and again, as usual, just before anastomotic construction. Video recordings of both ICGFA acquisitions were blindly quantified post hoc across selected colonic regions of interest (ROIs) using tracking-quantification software and computationally compared with satisfactory perfusion assumed in second time-point ROIs, demonstrating 85% agreement with baseline ICGFA. ROI quantification outputs detailing projected perfusion sufficiency-insufficiency zones were compared to the actual surgeon-selected transection/anastomotic construction site for left/right-sided resections, respectively. Anastomotic outcomes were recorded, and tissue lactate was also measured in the devascularised colonic segment in a subgroup of patients. The novel perfusion zone projections were developed as full-screen recommendations via overlay heatmaps. RESULTS: No patient suffered intra- or early postoperative anastomotic complications. Following computational development (n = 14) the software recommended zone (ROI) contained the expert surgical site of transection in almost all cases (Jaccard similarity index 0.91) of the nine patient validation series. Previously published ICGFA time-series milestone descriptors correlated moderately well, but lactate measurements did not. High resolution augmented reality heatmaps presenting recommendations from all pixels of the bowel ICGFA were generated for all cases. CONCLUSIONS: By benchmarking to the patient's own baseline perfusion, this novel QICGFA method could allow the deployment of algorithmic personalised NIR bowel transection point recommendation in a way fitting existing clinical workflow.


Assuntos
Anastomose Cirúrgica , Angiofluoresceinografia , Verde de Indocianina , Humanos , Feminino , Masculino , Anastomose Cirúrgica/métodos , Idoso , Angiofluoresceinografia/métodos , Pessoa de Meia-Idade , Calibragem , Colo/cirurgia , Colo/irrigação sanguínea , Estudo de Prova de Conceito , Colectomia/métodos , Monitorização Intraoperatória/métodos , Neoplasias Colorretais/cirurgia
2.
Surg Endosc ; 38(1): 426-436, 2024 01.
Artigo em Inglês | MEDLINE | ID: mdl-37985488

RESUMO

INTRODUCTION: Gas leaks polluting the operating room are common in laparoscopy. Studies defining methods for sensitive leak characterisation and mechanical mitigation in real world settings are, however, lacking. METHODS: Mobile optical gas imagers (both a miniaturised Schlieren system and sensitive tripod-mounted near-infrared carbon dioxide camera (GF343, FLIR)) prospectively defined trocar-related gas leaks occurring either spontaneously or with instrumentation during planned laparoscopic surgery at three hospitals. A boutique Matlab-based analyser using sequential frame subtraction categorised leaks (class 0-no observable leak; class 1-marginally detectable leak; class 2-short-lived plume; class 3-energetic, turbulent jet). Concurrently, the usefulness of a novel vacuum-ring device (LeakTrap™, Palliare, Ireland) designed as a universal adjunct for existing standard laparoscopic ports at both abdominal wall and port valve level was determined similarly in a phase I/11 clinical trial along with the device's useability through procedural observation and surgeon questionnaire. RESULTS: With ethical and regulatory approval, 40 typical patients (mean age 58.6 years, 20 males) undergoing planned laparoscopic cholecystectomy (n = 36) and hernia repair (n = 4) were studied comprising both control (n = 20) and intervention (n = 20) cohorts. Dual optical gas imaging was successfully performed across all procedures with minimal impact on procedural flow. In total, 1643 trocar instrumentations were examined, 819 in the control group (mean 41 trocar instrumentations/procedure) and 824 in the intervention group (mean 41.2 trocar instrumentations/procedure). Gas leaks were detected during 948(62.6%) visualised trocar instrumentations (in 129-7.8%-the imaging was obscured). 14.8% (110/742) and 60% (445/742) of leaks in control patients were class 0 and 3, respectively, versus 59.1% (456/770) and 8.7% (67/772) in the interventional group (class 3 v non-class 3, p < 0.0001, χ2). The Leaktrap proved surgically acceptable without significant workflow disruption. CONCLUSION: Laparoscopic gas leaks can be sensitively detected and consistently, effectively mitigated using straightforward available-now technology with most impact on the commonest, highest energy instrument exchange leaks.


Assuntos
Parede Abdominal , Colecistectomia Laparoscópica , Laparoscopia , Masculino , Humanos , Pessoa de Meia-Idade , Estudos Prospectivos , Laparoscopia/efeitos adversos , Laparoscopia/métodos , Colecistectomia Laparoscópica/métodos , Parede Abdominal/cirurgia , Instrumentos Cirúrgicos
3.
Surg Endosc ; 38(3): 1306-1315, 2024 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-38110792

RESUMO

AIM/BACKGROUND: Intra-operative colonic perfusion assessment via indocyanine green fluorescence angiography (ICGFA) aims to address malperfusion-related anastomotic complications; however, its interpretation suffers interuser variability (IUV), especially early in ICGFA experience. This work assesses the impact of a protocol developed for both operator-based judgement and computational development on interpretation consistency, focusing on senior surgeons yet to start using ICGFA. METHODS: Experienced and junior gastrointestinal surgeons were invited to complete an ICGFA-experience questionnaire. They subsequently interpreted nine operative ICGFA videos regarding perfusion sufficiency of a surgically prepared distal colon during laparoscopic anterior resection by indicating their preferred site of proximal transection using an online annotation platform (mindstamp.com). Six ICGFA videos had been prepared with a clinical standardisation protocol controlling camera and patient positioning of which three each had monochrome near infrared (NIR) and overlay display. Three others were non-standardised controls with synchronous NIR and overlay picture-in-picture display. Differences in transection level between different cohorts were assessed for intraclass correlation coefficient (ICC) via ImageJ and IBM SPSS. RESULTS: 58 clinicians (12 ICGFA experts, 46 ICGFA inexperienced of whom 23 were either finished or within one year of finishing training and 23 were junior trainees) participated as per power calculations. 63% felt that ICGFA should be routinely deployed with 57% believing interpretative competence requires 11-50 cases. Transection level concordance was generally good (ICC = 0.869) across all videos and levels of expertise (0.833-0.915). However, poor agreement was evident with the standardised protocol videos for overlay presentation (0.208-0.345). Similarly, poor agreement was seen for the monochrome display (0.392-0.517), except for those who were trained but ICG inexperienced (0.877) although even here agreement was less than with unstandardised videos (0.943). CONCLUSION: Colorectal ICGFA acquisition and display standardisation impacts IUV with this specific protocol tending to diminish surgeon interpretation consistency. ICGFA video recording for computational development may require dedicated protocols.


Assuntos
Neoplasias Colorretais , Cirurgia Colorretal , Humanos , Verde de Indocianina , Angiofluoresceinografia , Neoplasias Colorretais/diagnóstico por imagem , Neoplasias Colorretais/cirurgia , Fístula Anastomótica , Cirurgia Colorretal/métodos , Anastomose Cirúrgica/métodos
4.
Langenbecks Arch Surg ; 409(1): 170, 2024 Jun 01.
Artigo em Inglês | MEDLINE | ID: mdl-38822883

RESUMO

PURPOSE: Perioperative decision making for large (> 2 cm) rectal polyps with ambiguous features is complex. The most common intraprocedural assessment is clinician judgement alone while radiological and endoscopic biopsy can provide periprocedural detail. Fluorescence-augmented machine learning (FA-ML) methods may optimise local treatment strategy. METHODS: Surgeons of varying grades, all performing colonoscopies independently, were asked to visually judge endoscopic videos of large benign and early-stage malignant (potentially suitable for local excision) rectal lesions on an interactive video platform (Mindstamp) with results compared with and between final pathology, radiology and a novel FA-ML classifier. Statistical analyses of data used Fleiss Multi-rater Kappa scoring, Spearman Coefficient and Frequency tables. RESULTS: Thirty-two surgeons judged 14 ambiguous polyp videos (7 benign, 7 malignant). In all cancers, initial endoscopic biopsy had yielded false-negative results. Five of each lesion type had had a pre-excision MRI with a 60% false-positive malignancy prediction in benign lesions and a 60% over-staging and 40% equivocal rate in cancers. Average clinical visual cancer judgement accuracy was 49% (with only 'fair' inter-rater agreement), many reporting uncertainty and higher reported decision confidence did not correspond to higher accuracy. This compared to 86% ML accuracy. Size was misjudged visually by a mean of 20% with polyp size underestimated in 4/6 and overestimated in 2/6. Subjective narratives regarding decision-making requested for 7/14 lesions revealed wide rationale variation between participants. CONCLUSION: Current available clinical means of ambiguous rectal lesion assessment is suboptimal with wide inter-observer variation. Fluorescence based AI augmentation may advance this field via objective, explainable ML methods.


Assuntos
Colonoscopia , Neoplasias Retais , Humanos , Neoplasias Retais/patologia , Neoplasias Retais/cirurgia , Neoplasias Retais/diagnóstico por imagem , Pólipos Intestinais/patologia , Pólipos Intestinais/cirurgia , Aprendizado de Máquina , Masculino , Fluorescência , Feminino , Variações Dependentes do Observador
5.
Surg Technol Int ; 442024 04 16.
Artigo em Inglês | MEDLINE | ID: mdl-38629713

RESUMO

Transanal minimally invasive surgery (TAMIS) is an effective procedure that plays an important role in the care of patients with significant rectal neoplasia and polyps including early-stage cancers. However, it is perhaps underutilised and under threat from both advanced flexible endoscopic procedures and proceduralists (who often act as gatekeepers for referral to colorectal surgeons), as well as from robotic surgery proponents. TAMIS advocates can learn and adopt practice insights from both these fields and incorporate available technological innovations building on the huge accomplishments already delivered in this area. Evolved practice through technology has the potential to offset current limitations regarding technical constraints and indeed patient selection (via artificial intelligence methods). Potential target areas for advances are considered in this review from different perspectives: (1) Access (2) Insufflation (3) Visualisation (4) Disease Characterization in situ, and (5) Tissue Handling and Suturing. While a bundle approach may be most useful, the advances for each component are potentially useful in their own right and could be applied without depending on the other practices detailed so that more accurate (and perhaps even numerically more) TAMIS procedures can be performed globally to improve patient care.

6.
Dis Colon Rectum ; 66(12): e1265-e1268, 2023 12 01.
Artigo em Inglês | MEDLINE | ID: mdl-37787571

RESUMO

BACKGROUND: The constrained access associated with transanal minimally invasive surgery has led surgeons to deploy robotic-assisted platforms to offset inherent maneuverability limitations and, perhaps, skills deficits. IMPACT OF INNOVATION: A handheld, powered 5-mm lightweighted laparoendoscopic electromechanical digital device (HandX, HumanXtensions, Israel) with hardware and software components that convert surgical hand movements precisely to the instrument's articulating tip and enable robotic transanal minimally invasive surgery with full tip roticulation for hook diathermy and suturing. TECHNOLOGY, MATERIALS, AND METHODS: After bench and biomedical model training, HandX was used in 3 transanal minimally invasive surgery procedures (2 male patients and 1 female patient, mean age 66.3 years). The rectal lesions averaged 30 mm in maximum dimension and were located posteriorly (n = 2) and laterally (n = 1) a mean of 3 cm from the anal verge. Standard transanal minimally invasive surgery setup and instrumentation (Gelport Path, Applied Medical with Airseal, and Conmed) were used, adding the HandX device for circumferential lesion marking and hemostatic full-thickness excision as well as defect suturing where appropriate. PRELIMINARY RESULTS: All procedures were completed without undue prolongation (operating times <1 hour) despite nuisance hemorrhoidal bleeding in 1 patient. All lesions were fully excised, with 2 being T1 cancers and 1 tubulovillous adenoma with high-grade dysplasia. All patients were discharged within 48 hours postoperatively (1 experienced secondary hemorrhage on postoperative day 5). CONCLUSIONS AND FUTURE DIRECTIONS: HandX capably facilitated endoscopic robot-like instrument movement for transanal minimally invasive surgery without disrupting workflows. With time dedicated to instrument understanding and training, HandX increased dexterity with a small operating room footprint and may offer greater cost-effectiveness than other platforms.


Assuntos
Adenoma , Neoplasias Retais , Cirurgia Endoscópica Transanal , Humanos , Masculino , Feminino , Idoso , Neoplasias Retais/cirurgia , Neoplasias Retais/patologia , Reto/cirurgia , Cirurgia Endoscópica Transanal/métodos , Canal Anal/cirurgia , Canal Anal/patologia , Adenoma/patologia , Procedimentos Cirúrgicos Minimamente Invasivos
7.
Surg Endosc ; 37(8): 6361-6370, 2023 08.
Artigo em Inglês | MEDLINE | ID: mdl-36894810

RESUMO

INTRODUCTION: Indocyanine green (ICG) quantification and assessment by machine learning (ML) could discriminate tissue types through perfusion characterisation, including delineation of malignancy. Here, we detail the important challenges overcome before effective clinical validation of such capability in a prospective patient series of quantitative fluorescence angiograms regarding primary and secondary colorectal neoplasia. METHODS: ICG perfusion videos from 50 patients (37 with benign (13) and malignant (24) rectal tumours and 13 with colorectal liver metastases) of between 2- and 15-min duration following intravenously administered ICG were formally studied (clinicaltrials.gov: NCT04220242). Video quality with respect to interpretative ML reliability was studied observing practical, technical and technological aspects of fluorescence signal acquisition. Investigated parameters included ICG dosing and administration, distance-intensity fluorescent signal variation, tissue and camera movement (including real-time camera tracking) as well as sampling issues with user-selected digital tissue biopsy. Attenuating strategies for the identified problems were developed, applied and evaluated. ML methods to classify extracted data, including datasets with interrupted time-series lengths with inference simulated data were also evaluated. RESULTS: Definable, remediable challenges arose across both rectal and liver cohorts. Varying ICG dose by tissue type was identified as an important feature of real-time fluorescence quantification. Multi-region sampling within a lesion mitigated representation issues whilst distance-intensity relationships, as well as movement-instability issues, were demonstrated and ameliorated with post-processing techniques including normalisation and smoothing of extracted time-fluorescence curves. ML methods (automated feature extraction and classification) enabled ML algorithms glean excellent pathological categorisation results (AUC-ROC > 0.9, 37 rectal lesions) with imputation proving a robust method of compensation for interrupted time-series data with duration discrepancies. CONCLUSION: Purposeful clinical and data-processing protocols enable powerful pathological characterisation with existing clinical systems. Video analysis as shown can inform iterative and definitive clinical validation studies on how to close the translation gap between research applications and real-world, real-time clinical utility.


Assuntos
Neoplasias Colorretais , Verde de Indocianina , Humanos , Neoplasias Colorretais/cirurgia , Neoplasias Colorretais/patologia , Computadores , Estudos Prospectivos , Reprodutibilidade dos Testes
8.
Molecules ; 28(5)2023 Feb 25.
Artigo em Inglês | MEDLINE | ID: mdl-36903411

RESUMO

A series of mono- and bis-polyethylene glycol (PEG)-substituted BF2-azadipyrromethene fluorophores have been synthesized with emissions in the near-infrared region (700-800 nm) for the purpose of fluorescence guided intraoperative imaging; chiefly ureter imaging. The Bis-PEGylation of fluorophores resulted in higher aqueous fluorescence quantum yields, with PEG chain lengths of 2.9 to 4.6 kDa being optimal. Fluorescence ureter identification was possible in a rodent model with the preference for renal excretion notable through comparative fluorescence intensities from the ureters, kidneys and liver. Ureteral identification was also successfully performed in a larger animal porcine model under abdominal surgical conditions. Three tested doses of 0.5, 0.25 and 0.1 mg/kg all successfully identified fluorescent ureters within 20 min of administration which was sustained up to 120 min. 3-D emission heat map imaging allowed the spatial and temporal changes in intensity due to the distinctive peristaltic waves of urine being transferred from the kidneys to the bladder to be identified. As the emission of these fluorophores could be spectrally distinguished from the clinically-used perfusion dye indocyanine green, it is envisaged that their combined use could be a step towards intraoperative colour coding of different tissues.


Assuntos
Espectroscopia de Luz Próxima ao Infravermelho , Ureter , Suínos , Animais , Espectroscopia de Luz Próxima ao Infravermelho/métodos , Corantes Fluorescentes/química , Rim , Bexiga Urinária , Polietilenoglicóis/química , Imagem Óptica/métodos
9.
Surg Endosc ; 36(9): 7047-7055, 2022 09.
Artigo em Inglês | MEDLINE | ID: mdl-35503476

RESUMO

INTRODUCTION: The advent of the COVID-19 pandemic led to recommendations aimed at minimizing the risk of gas leaks at laparoscopy. As this has continuing relevance including regarding operating room pollution, we empirically quantified carbon dioxide (CO2) leak jet velocity (important for particle propulsion) occurring with different instruments inserted into differing trocars repeated across a range of intra-abdominal pressures (IAPs) and modern insufflators in an experimental model. METHOD: Laparoscopic gas plume leak velocity (metres/second) was computationally enumerated from schlieren optical flow videography on a porcine cadaveric laparoscopic model with IAPs of 4-5, 7-8, 12-15 and 24-25 mmHg (repeated with 5 different insufflators) during simulated operative use of laparoscopic clip appliers, scissors, energy device, camera and staplers as well as Veres needle (positive control) and trocar obturator (negative control) in fresh 5 mm and 12 mm ports. RESULTS: Close-fitting solid instruments (i.e. cameras and obturators) demonstrated slower gas leak velocities in both the 5 mm and 12 mm ports (p = 0.02 and less than 0.001) when compared to slimmer instruments, however, hollow instrument designs were seen to defy this pattern with the endoscopic linear stapler visibly inducing multiple rapid jests even when compared to similarly sized clip appliers (p = 0.03). However, on a per device basis the operating instrumentation displayed plume speeds which did not vary significantly when challenged with varying post size, IAP and a range of insufflators. CONCLUSION: In general, surgeon's selection of instrument, port or pressure does not usefully mitigate trocar CO2 leak velocity. Instead better trocar design is needed, helped by a fuller understanding of trocar valve mechanics via computational fluid dynamics informed by relevant surgical modelling.


Assuntos
COVID-19 , Insuflação , Laparoscopia , Animais , Dióxido de Carbono , Humanos , Laparoscopia/efeitos adversos , Pandemias , Suínos
10.
Surg Endosc ; 36(12): 8764-8773, 2022 12.
Artigo em Inglês | MEDLINE | ID: mdl-35543771

RESUMO

INTRODUCTION: Indocyanine green fluorescence angiography (ICGFA) is commonly used in colorectal anastomotic practice with limited pre-training. Recent work has shown that there is considerable inconsistency in signal interpretation between surgeons with minimal or no experience versus those consciously invested in mastery of the technique. Here, we deconstruct the fluorescence signal patterns of expert-annotated surgical ICGFA videos to understand better their correlation and combine this with structured interviews to ascertain whether such interpretative capability is conscious or unconscious. METHODS: For fluorescence signal analysis, expert-annotated ICGFA videos (n = 24) were quantitatively interrogated using a boutique intensity tracker (IBM Research) to generate signal time plots. Such fluorescence intensity data were examined for inter-observer correlation (Intraclass Correlation Coefficients, ICC) at specific curve milestones: the maximum fluorescence signal (Fmax), the times to both achieve this maximum (Tmax), as well as half this maximum (T1/2max) and the ratio between these (T1/2/Tmax). Formal tele-interview with contributing experts (n = 6) was conducted with the narrative transcripts being thematically mapped, plotted, and qualitatively analyzed. RESULTS: Correlation by mathematical measures was excellent (ICC0.9-1.0) for Fmax, Tmax, and T1/2max (0.95, 0.938, and 0.925, respectively) and moderate (0.5-0.75) for T1/2/Tmax (0.729). While all experts narrated a deliberate viewing strategy, their specific dynamic signal appreciation differed in the manner of description. CONCLUSION: Expert ICGFA users demonstrate high correlation in mathematical measures of their signal interpretation although do so tacitly. Computational quantification of expert behavior can help develop the necessary lexicon and training sets as well as computer vision methodology to better exploit ICGFA technology.


Assuntos
Neoplasias Colorretais , Verde de Indocianina , Humanos , Angiofluoresceinografia/métodos , Anastomose Cirúrgica/métodos , Reto/cirurgia , Neoplasias Colorretais/diagnóstico por imagem , Neoplasias Colorretais/cirurgia , Fístula Anastomótica
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA