Ann Thorac Surg ; 115(3): 641-648, 2023 03.
Artigo em Inglês | MEDLINE | ID: mdl-35031286

RESUMO

BACKGROUND: We aim to identify the incidence and timing of dysfunction and failure of stented bioprosthetic valves in the pulmonary position in congenital heart disease patients. METHODS: A total of 482 congenital heart disease patients underwent 484 stented bioprosthetic pulmonary valve implantations between 2008 and 2018. There were 164 porcine valves (Porcine) and 320 bovine pericardial valves (Pericardial) implanted. Primary endpoints were survival, valve dysfunction, and valve failure. RESULTS: Pericardial valves were implanted in older patients (22.0, interquartile range [IQR] 14-33 vs 16.0, IQR 11-23 years, P < 0.001). Five-year survival (96.7% vs 97.9%) for the Pericardial and Porcine groups, respectively, were similar, P > 0.05. Forty-six (34%) Porcine and 75 (27%) Pericardial group patients met criteria for valve dysfunction at a median echocardiographic follow-up time of 7.43 years (IQR 4.1-9.5 years) and 3.26 years (IQR 1.7-4.7 years), respectively. More Pericardial group patients suffered from at least mild late PR while late median peak gradient was higher in the Porcine group, P < .001 for both. Risk factors for valve dysfunction included decreasing patient age for the entire cohort (hazard ratio [HR] 1.02, 95% confidence interval [CI] 1.00-1.04, P = .015) and lack of anticoagulation at discharge for the Porcine group (HR 3.06, 95% CI 1.03-9.10, P = .044) but not the Pericardial group. Five-year cumulative incidence of dysfunction was 39% for the Pericardial group and 17% for the Porcine group. CONCLUSIONS: Porcine stented and bovine pericardial stented valves can be implanted in the pulmonary position in all age groups safely. However, despite similar rates of valve failure, bovine pericardial stented valves have a higher incidence of valve dysfunction at mid-term follow-up.


Assuntos
Bioprótese , Cardiopatias Congênitas , Implante de Prótese de Valva Cardíaca , Próteses Valvulares Cardíacas , Valva Pulmonar , Animais , Bovinos , Suínos , Valva Pulmonar/cirurgia , Próteses Valvulares Cardíacas/efeitos adversos , Implante de Prótese de Valva Cardíaca/efeitos adversos , Bioprótese/efeitos adversos , Cardiopatias Congênitas/cirurgia , Cardiopatias Congênitas/etiologia , Desenho de Prótese , Valva Aórtica/cirurgia
2.
Ann Thorac Surg ; 114(3): 643-649, 2022 09.
Artigo em Inglês | MEDLINE | ID: mdl-35031292

RESUMO

BACKGROUND: We reviewed the clinical outcomes of a novel method of aortic root replacement using a self-constructed tissue valve conduit composed of a Freestyle subcoronary valve sewn into a Valsalva graft. METHODS: From 2005 to 2020, 523 patients had aortic root replacement operations using a self-constructed Freestyle subcoronary-Valsalva graft tissue valve conduit. Median patient age was 62 years (interquartile range [IQR] 54-70), and 430 (82%) were men. Primary outcomes were mortality and the need for reoperation. Multivariable regression analyses were performed to identify risk factors for mortality and reoperation. RESULTS: Urgent procedures comprised 48.37% of cases, and 29.26% were reoperative procedures. Concomitant ascending aorta replacement, hemiarch replacement, and total arch replacement were required in 348 (67%), 227 (44%), and 40 (8%) patients, respectively. Cardiopulmonary bypass and cross-clamp times were 189 minutes (IQR, 164-218) and 166 minutes (IQR, 145-191), respectively. Early mortality was 7.7% (40), and 5- and 10-year survival rates were 83% and 71%, respectively. At the last echocardiogram follow-up left ventricular ejection fraction, left ventricular end-diastolic diameter, degree of aortic insufficiency, and mean aortic valve gradient were significantly improved from baseline (P < .001). Increasing age, peripheral artery disease, tobacco use, increased preoperative creatinine, and prior aortic valve surgery were risk factors for both mortality and the composite outcome (P < .02). CONCLUSIONS: In a complex patient population aortic root replacement using a self-constructed composite tissue valve conduit comprising a Freestyle subcoronary valve-Valsalva graft can be performed with excellent operative and 10-year outcomes. Midterm survival was acceptable, and valve durability was outstanding with an exceedingly low incidence for valve reintervention.


Assuntos
Bioprótese , Implante de Prótese de Valva Cardíaca , Aorta/cirurgia , Valva Aórtica/diagnóstico por imagem , Valva Aórtica/cirurgia , Feminino , Implante de Prótese de Valva Cardíaca/métodos , Humanos , Masculino , Pessoa de Meia-Idade , Complicações Pós-Operatórias/etiologia , Reoperação , Estudos Retrospectivos , Volume Sistólico , Resultado do Tratamento , Função Ventricular Esquerda