Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 9 de 9
Filtrar
1.
Environ Sci Pollut Res Int ; 29(29): 44404-44412, 2022 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-35133597

RESUMO

Previous ecological studies suggest the existence of possible interplays between the exposure to air pollutants and SARS-CoV-2 infection. Confirmations at individual level, however, are lacking. To explore the relationships between previous exposure to particulate matter < 10 µm (PM10) and nitrogen dioxide (NO2), the clinical outcome following hospital admittance, and lymphocyte subsets in COVID-19 patients with pneumonia. In 147 geocoded patients, we assessed the individual exposure to PM10 and NO2 in the 2 weeks before hospital admittance. We divided subjects according to the clinical outcome (i.e., discharge at home vs in-hospital death), and explored the lymphocyte-related immune function as an index possibly affecting individual vulnerability to the infection. As compared with discharged subjects, patients who underwent in-hospital death presented neutrophilia, lymphopenia, lower number of T CD45, CD3, CD4, CD16/56 + CD3 + , and B CD19 + cells, and higher previous exposure to NO2, but not PM10. Age and previous NO2 exposure were independent predictors for mortality. NO2 concentrations were also negatively related with the number of CD45, CD3, and CD4 cells. Previous NO2 exposure is a co-factor independently affecting the mortality risk in infected individuals, through negative immune effects. Lymphopenia and altered lymphocyte subsets might precede viral infection due to nonmodifiable (i.e., age) and external (i.e., air pollution) factors. Thus, decreasing the burden of air pollutants should be a valuable primary prevention measure to reduce individual susceptibility to SARS-CoV-2 infection and mortality.


Assuntos
Poluentes Atmosféricos , Poluição do Ar , COVID-19 , Linfopenia , Poluentes Atmosféricos/análise , Poluição do Ar/análise , Exposição Ambiental/análise , Mortalidade Hospitalar , Humanos , Imunidade , Linfopenia/induzido quimicamente , Dióxido de Nitrogênio/análise , Material Particulado/análise , SARS-CoV-2
2.
Clin Ter ; 137(2): 77-82, 1991 Apr 30.
Artigo em Italiano | MEDLINE | ID: mdl-1828407

RESUMO

Raynaud's phenomenon (Raynaud's disease), an accessual vascular acrosyndrome characterised by an important constriction of distal arterioles, has still no specific pharmacological therapy. In the last years, the use of calcium-entry-blockers (nifedipine, diltiazem, verapamil, nicardipine), drugs able to control the contractility of the vessels, showed some positive results. Considering this data, we appraised the efficacy of flunarizine, another calcium-entry-blocker, in a preliminary study of 28 patients (23 females, 5 males, aged between 15 and 48 years) suffering from Raynaud's disease. Apart from a statistically insignificant improvement of subjective symptoms (i.e. acroparesthesias, cold extremities) flunarizine (10 mg/day for 1 month) did not have positive results. Finally, this drug caused some side-effects: drowsiness, increase of weight and appetite, but without a real necessity for withdrawal of therapy.


Assuntos
Flunarizina/uso terapêutico , Doença de Raynaud/tratamento farmacológico , Adolescente , Adulto , Feminino , Flunarizina/administração & dosagem , Flunarizina/efeitos adversos , Humanos , Masculino , Pessoa de Meia-Idade , Fatores de Tempo
4.
Cephalalgia ; 10(1): 17-24, 1990 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-2317849

RESUMO

The use of flunarizine, a drug which has proven its efficacy in migraine, is often associated with important side effects. The aim of this paper has been to check their incidence at different dose levels (5 mg vs 10 mg). Our data confirm the occurrence of important side effects (in particular weight gain); on the other hand, they emphasize the dose-dependency of the side effects.


Assuntos
Analgésicos/uso terapêutico , Flunarizina/uso terapêutico , Transtornos de Enxaqueca/tratamento farmacológico , Adulto , Relação Dose-Resposta a Droga , Feminino , Flunarizina/efeitos adversos , Humanos , Masculino , Pessoa de Meia-Idade , Aumento de Peso/efeitos dos fármacos
5.
Pacing Clin Electrophysiol ; 23(11 Pt 2): 1801-3, 2000 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-11139928

RESUMO

UNLABELLED: Evaluation of the quality of atrial sensing is indispensable to monitor the performance of VDD single-lead systems. In addition to counters, a new VDD system offers storage of intracardiac electrograms (EGMs). The clinical contribution of stored EGMs in a VDD pacemaker was prospectively examined in a multicenter study, and the reliability of its counters was evaluated on the basis of EGM information. METHODS: A VDD system (Pulsar 870, Guidant Co.) was implanted in 46 patients with atrioventricular block. EGM storage was activated upon detection of ventricular tachycardia (VT), recurrent premature ventricular complexes (PVCs), and mode switch ("atrial tachy reaction," ATR). Stored EGMs were retrieved before discharge of the patients from the hospital, and at 6-week, 3-month, and 6-month follow-up. RESULTS: A total of 440 stored EGMs were retrieved and analyzed. Of 30 VT episodes detected, 2 (7%) were confirmed, and all others were attributable to ventricular oversensing. One postmortem interrogation documented VT as the cause of sudden death. Of 175 EGMs stored upon detection of PVCs, 43 episodes (25%) were confirmed and 124 (70%) showed intermittent atrial undersensing with spontaneous AV conduction; in 8 episodes (5%) no abnormality was observed. Of 235 episodes stored upon ATR, 82 (35%) were confirmed and 153 were due to atrial oversensing. CONCLUSIONS: (1). Stored EGMs indicated a high percentage (69%) of event misdiagnosis by the pacemaker. Thus, pacemaker counter information without the availability of stored EGMs should be interpreted with caution. (2). Misclassified events are of high clinical importance since they unmask otherwise unsuspected intermittent under- or oversensing.


Assuntos
Dispositivos de Armazenamento em Computador , Bloqueio Cardíaco/diagnóstico , Bloqueio Cardíaco/terapia , Armazenamento e Recuperação da Informação/métodos , Marca-Passo Artificial , Idoso , Eletrodos Implantados , Feminino , Seguimentos , Átrios do Coração/fisiopatologia , Bloqueio Cardíaco/fisiopatologia , Humanos , Masculino , Valor Preditivo dos Testes , Estudos Prospectivos , Tempo de Reação , Reprodutibilidade dos Testes
6.
Cephalalgia ; 7(3): 167-8, 1987 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-3652197

RESUMO

A case of "hemicrania continua" after cluster headache in the same subject is described. Indomethacin exerted an absolute, persistent effect on the present headache. Even though our data are insufficient to demonstrate a causal relation between the two forms of headache, they do suggest this real possibility.


Assuntos
Cefaleia Histamínica/complicações , Transtornos de Enxaqueca/diagnóstico , Cefaleias Vasculares/complicações , Feminino , Humanos , Indometacina/uso terapêutico , Pessoa de Meia-Idade , Transtornos de Enxaqueca/complicações , Transtornos de Enxaqueca/tratamento farmacológico
7.
Europace ; 4(2): 129-35, 2002 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-12135243

RESUMO

AIM: The purpose of this study was to evaluate the performance of a new VDD pacing system incorporating a high impedance, single-pass VDD lead. The new lead is a bipolar, steroid-eluting, high impedance lead with a full-ring atrial dipole. METHODS AND RESULTS: The system was implanted in 46 patients with high degree atrioventricular (AV) block. Patients were followed at pre-discharge, 6 weeks, and 3 months. The mean measured P-wave amplitude was stable, with values between 1.18 and 1.43 mV. Atrial sensing was reliable during short-term evaluation at rest and in the sitting position, with AV-synchronous stimulation between 98.79 +/- 6.90% and 99.73 +/- 1.47%. Holter recordings after 6 weeks demonstrated AV-synchronous stimulation in 99.57 1.03% of all P-waves. Lead impedance was stable during follow-up, with mean values between 1000 and 1167 Q. Mean ventricular pacing thresholds (at 0.5 ms) were 0.47 V at implant, 0.49 V at pre-discharge, 0.74 V at 6 weeks, and 0.72 V at 3 months. R-wave amplitude remained stable between 14.9 and 16.7 mV during follow-up. CONCLUSION: This new single-pass VDD lead system provided reliable atrial sensing and stable high impedance stimulation during a 3-month follow-up period.


Assuntos
Estimulação Cardíaca Artificial , Idoso , Estimulação Cardíaca Artificial/métodos , Cardiomiopatia Dilatada/terapia , Doença da Artéria Coronariana/terapia , Impedância Elétrica , Eletrocardiografia Ambulatorial , Feminino , Humanos , Masculino , Pessoa de Meia-Idade
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA