Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 46
Filtrar
Mais filtros

Base de dados
País/Região como assunto
Tipo de documento
Intervalo de ano de publicação
1.
Ultrasound Obstet Gynecol ; 63(4): 489-496, 2024 04.
Artigo em Inglês | MEDLINE | ID: mdl-37725758

RESUMO

OBJECTIVE: To compare the performance of two-dimensional ultrasound (2D-US), three-dimensional ultrasound (3D-US) and magnetic resonance imaging (MRI) at 36 weeks' gestation in predicting the delivery of a large-for-gestational-age (LGA) neonate, defined as birth weight ≥ 95th percentile, in patients at high and low risk for macrosomia. METHODS: This was a secondary analysis of a prospective observational study conducted between January 2017 and February 2019. Women with a singleton pregnancy at 36 weeks' gestation underwent 2D-US, 3D-US and MRI within 15 min for estimation of fetal weight. Weight estimations and birth weight were plotted on a growth curve to obtain percentiles for comparison. Participants were considered high risk if they had at least one of the following risk factors: diabetes mellitus, estimated fetal weight ≥ 90th percentile at the routine third-trimester ultrasound examination, obesity (prepregnancy body mass index ≥ 30 kg/m2) or excessive weight gain during pregnancy. The outcome was the diagnostic performance of each modality in the prediction of birth weight ≥ 95th percentile, expressed as the area under the receiver-operating-characteristics curve (AUC), sensitivity, specificity and positive and negative predictive values. RESULTS: A total of 965 women were included, of whom 533 (55.23%) were high risk and 432 (44.77%) were low risk. In the low-risk group, the AUCs for birth weight ≥ 95th percentile were 0.982 for MRI, 0.964 for 2D-US and 0.962 for 3D-US; pairwise comparisons were non-significant. In the high-risk group, the AUCs were 0.959 for MRI, 0.909 for 2D-US and 0.894 for 3D-US. A statistically significant difference was noted between MRI and both 2D-US (P = 0.002) and 3D-US (P = 0.002), but not between 2D-US and 3D-US (P = 0.503). In the high-risk group, MRI had the highest sensitivity (65.79%) compared with 2D-US (36.84%, P = 0.002) and 3D-US (21.05%, P < 0.001), whereas 3D-US had the highest specificity (98.99%) compared with 2D-US (96.77%, P = 0.005) and MRI (96.97%, P = 0.004). CONCLUSIONS: At 36 weeks' gestation, MRI has better performance compared with 2D-US and 3D-US in predicting birth weight ≥ 95th percentile in patients at high risk for macrosomia, whereas the performance of 2D-US and 3D-US is comparable. For low-risk patients, the three modalities perform similarly. © 2023 International Society of Ultrasound in Obstetrics and Gynecology.


Assuntos
Macrossomia Fetal , Peso Fetal , Gravidez , Recém-Nascido , Humanos , Feminino , Lactente , Peso ao Nascer , Macrossomia Fetal/diagnóstico por imagem , Idade Gestacional , Ultrassonografia Pré-Natal/métodos , Recém-Nascido Pequeno para a Idade Gestacional , Imageamento por Ressonância Magnética
2.
Artigo em Inglês | MEDLINE | ID: mdl-38477187

RESUMO

OBJECTIVE: Large-for-gestational-age (LGA) is associated with several adverse maternal and neonatal outcomes. Although many studies have found that early induction of labor (eIOL) in LGA reduces the incidence of shoulder dystocia (SD), no current guidelines recommend this particular strategy, due to concerns about increased rates of cesarean delivery (CD) and neonatal complications. The purpose of this study was to assess whether the timing of IOL in LGA fetuses affects maternal and neonatal outcomes in a single center; and to combine these results with the evidence reported in the literature. METHODS: This study comprised two parts. The first was a retrospective cohort study that included: consecutive patients with singleton pregnancy, an estimated fetal weight (EFW) ≥90th percentile on ultrasound (US) between 35+0 and 39+0 weeks of gestation (WG), who were eligible for normal vaginal delivery. The second part was a systematic review of literature and meta-analysis that included the results of the first part as well as all previously reported studies that have compared IOL to expectant management in patients with LGA. The perinatal outcomes were CD, operative vaginal delivery (OVD), SD, brachial plexus palsy, anal sphincter injury, postpartum hemorrhage (PPH), APGAR score, umbilical arterial pH, neonatal intensive care unit (NICU) admission, use of continuous positive airway pressure (CPAP), intracranial hemorrhage (ICH), phototherapy, and bone fracture. RESULTS: Retrospective cohort: of the 547 patients, 329 (60.1%) were induced and 218 (39.9%) entered spontaneous labor. Following covariate balancing, CD was significantly higher in the IOL group in comparison to the spontaneous labor group. This difference only became apparent beyond 40WG (hazard ratio: 1.9, p=0.030). The difference between both groups for shoulder dystocia was not statistically significant. Systematic review and metanalysis: 17 studies were included in addition to our own results giving a total sample size of 111,300 participants. When IOL was performed <40+0WG, the risk for SD was significantly lower in the IOL group (OR: 0.64, 95%CI: 0.42-0.98, I2 =19%). There was no significant difference in CD rate between IOL and expectant management after pooling the results of these 17 studies. However, when removing the studies in which IOL was done exclusively before 40+0WG, the risk for CD in the remaining studies (IOL not exclusively <40+0WG) was significantly higher in the IOL group (odds ratio [OR]: 1.46, 95% confidence interval [95%CI]: 1.02-2.09, I2 =56%). There were no statistically significant differences between IOL and expectant management for the remaining perinatal outcomes. Nulliparity, history of CD, and low Bishop score but not methods of induction were independent risk factors for intrapartum CD in patients who were induced for LGA. CONCLUSION: Timing of IOL in patients with suspected macrosomia significantly impacts perinatal adverse outcomes. IOL has no impact on rates of SD but does increase CD when considered irrespective of gestational age, but it may decrease the risk of SD without increasing the risk of other adverse maternal outcomes, in particular cesarean section when performed before 40+0 WG. (GRADE: Low/Very low). This article is protected by copyright. All rights reserved.

3.
Ultrasound Obstet Gynecol ; 61(3): 392-398, 2023 03.
Artigo em Inglês | MEDLINE | ID: mdl-36773302

RESUMO

OBJECTIVE: To evaluate the prevalence of and risk factors for failure of fetal magnetic resonance imaging (MRI) due to maternal claustrophobia or malaise. METHODS: This retrospective cohort study included pregnant women who underwent fetal MRI for clinical indications or research purposes between January 2012 and December 2019 at a single center. One group included patients who completed the entire examination and the other group inlcuded patients who interrupted their MRI examination due to claustrophobia/malaise. We estimated the rate of MRI failure due to maternal claustrophobia/malaise and compared maternal and clinical variables between the two groups. Multiple logistic regression analysis was performed to identify independent risk factors for claustrophobia/malaise during MRI examination in pregnancy. RESULTS: Among 3413 patients who agreed to undergo fetal MRI, the prevalence of failure because of claustrophobia or malaise was 2.1%. The rate of claustrophobia/malaise in patients who underwent MRI for a clinical indication was lower compared to that in patients who underwent MRI for research purposes only (0.6% (4/696) vs 2.4% (65/2678); P = 0.003). Fetal MRI performed for research purposes only (adjusted odds ratio (aOR), 0.05 (95% CI, 0.01-0.48); P = 0.003), higher maternal age (aOR, 1.07 (95% CI, 1.02-1.12); P = 0.003) and later gestational age at the time of fetal MRI (aOR, 1.46 (95% CI, 1.16-2.04); P = 0.008) were independent risk factors for claustrophobia/malaise. Shorter fetal MRI duration (aOR, 0.77 (95% CI, 0.63-0.88); P = 0.001) was also associated with claustrophobia/malaise during the procedure. Body mass index, ethnic origin, multiple pregnancy, being parous and size of the magnetic bore were not associated with MRI failure due to claustrophobia/malaise. CONCLUSION: The rate of fetal MRI failure due to claustrophobia or malaise was found to be low, particularly when the examination was performed for a clinical indication, and should not be considered a common problem in the pregnant population. © 2022 International Society of Ultrasound in Obstetrics and Gynecology.


Assuntos
Transtornos Fóbicos , Humanos , Gravidez , Feminino , Estudos Retrospectivos , Prevalência , Fatores de Risco , Transtornos Fóbicos/complicações , Transtornos Fóbicos/epidemiologia , Imageamento por Ressonância Magnética/métodos
4.
Ultrasound Obstet Gynecol ; 57(3): 478-487, 2021 03.
Artigo em Inglês | MEDLINE | ID: mdl-32438461

RESUMO

OBJECTIVES: To validate prospectively the ADNEX magnetic resonance (MR) scoring system to assess adnexal masses and to evaluate a new, modified ADNEX MR scoring system that incorporates diffusion-weighted imaging (DWI) with apparent diffusion coefficient (ADC) mapping. METHODS: Between January 2015 and September 2018, 323 consecutive women with adnexal masses diagnosed on transvaginal ultrasound (TVS) underwent standardized MR imaging (MRI) including diffusion and dynamic contrast-enhanced sequences. Of these, 131 underwent subsequent surgery. For interpretation of the MRI examinations, we applied the five-category ADNEX MR scoring system, along with a modified scoring system including DWI with ADC mapping. For both scoring systems, a score was given for all adnexal masses. Histological diagnosis was considered as the gold standard and lesions were classified as benign or malignant. The difference between the predictive values for diagnosing malignancy of the classical and modified scoring systems was assessed on the basis of the areas under the receiver-operating-characteristics (AUC) curves. The sensitivity and specificity for diagnosing malignancy of each score were also calculated. RESULTS: Among the 131 women with adnexal mass(es) diagnosed on TVS who underwent MRI and subsequent surgery, the surgery revealed 161 adnexal masses in 126 women; five women had no mass. Histological examination confirmed 161 adnexal masses, of which all had been detected on MRI: 32 malignant tumors, 15 borderline tumors, which were classified as part of the malignant group (n = 47), and 114 benign lesions. The AUC for prediction of a malignant lesion was 0.938 (95% CI, 0.902-0.975) using the classical ADNEX MR scoring system and 0.974 (95% CI, 0.953-0.996) using the modified scoring system. Pairwise comparison of these AUCs revealed a significant difference (P = 0.0032). The sensitivity and specificity for diagnosing malignancy with an ADNEX MR score of 4 or more were 95.5% and 86.6%, respectively, using the classic scoring system, and 95.7% and 93.3%, respectively, using the modified scoring system. CONCLUSION: DWI with ADC mapping could be integrated into the ADNEX MR scoring system to improve specificity, thereby potentially optimizing clinical management by avoiding unnecessary surgery. © 2020 International Society of Ultrasound in Obstetrics and Gynecology.


Assuntos
Doenças dos Anexos/diagnóstico por imagem , Imagem de Difusão por Ressonância Magnética/métodos , Detecção Precoce de Câncer/estatística & dados numéricos , Neoplasias dos Genitais Femininos/diagnóstico por imagem , Processamento de Imagem Assistida por Computador/estatística & dados numéricos , Anexos Uterinos/diagnóstico por imagem , Adolescente , Adulto , Idoso , Idoso de 80 Anos ou mais , Área Sob a Curva , Meios de Contraste , Estudos Transversais , Diagnóstico Diferencial , Detecção Precoce de Câncer/métodos , Feminino , Humanos , Processamento de Imagem Assistida por Computador/métodos , Pessoa de Meia-Idade , Valor Preditivo dos Testes , Estudos Prospectivos , Curva ROC , Sensibilidade e Especificidade , Ultrassonografia/métodos , Vagina , Adulto Jovem
5.
Ultrasound Obstet Gynecol ; 54(6): 791-799, 2019 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-30644623

RESUMO

OBJECTIVE: To compare the diagnostic rate and accuracy of 3-Tesla (T) postmortem magnetic resonance imaging (PM-MRI) and postmortem ultrasound (PM-US) in an unselected fetal population. METHODS: We performed prospectively, in a blinded manner, 3-T PM-MRI and PM-US on 160 unselected fetuses at 13-41 weeks of gestation. All imaging was reported according to a prespecified template, for five anatomical regions: brain, thorax, heart, abdomen and spine. The rates of non-diagnostic results for PM-US and PM-MRI were compared and, for results that were diagnostic, we calculated sensitivity, specificity and concordance rates for each anatomical region, using conventional autopsy as the reference standard. RESULTS: 3-T PM-MRI performed significantly better than did PM-US overall and in particular for fetuses ≥ 20 weeks' gestation. Specifically, the non-diagnostic rates for PM-MRI vs PM-US were 4.4% vs 26.9% (7/160 vs 43/160; P < 0.001) for the brain, 5.2% vs 17.4% (8/155 vs 27/155; P < 0.001) for the thorax, 3.8% vs 30.6% (6/157 vs 48/157; P < 0.001) for the heart and 3.2% vs 23.6% (5/157 vs 37/157; P < 0.001) for the abdomen. For the spine, both techniques showed an equally low non-diagnostic rate. When both postmortem imaging techniques were diagnostic, they had similar accuracy, with no difference in sensitivity or specificity, and similar concordance with autopsy (PM-US, 79.5-96.5%; PM-MRI, 81.6-99.1%). CONCLUSIONS: PM-MRI performed significantly better than PM-US in this unselected population, due mainly to a lower non-diagnostic rate. PM-MRI should remain the first-line imaging investigation for perinatal autopsy, but PM-US could be considered if MRI is not available, albeit with a higher non-diagnostic rate. Copyright © 2019 ISUOG. Published by John Wiley & Sons Ltd.


Assuntos
Autopsia/métodos , Morte Fetal/etiologia , Feto/diagnóstico por imagem , Imageamento por Ressonância Magnética/métodos , Ultrassonografia/métodos , Abdome/diagnóstico por imagem , Aborto Induzido/estatística & dados numéricos , Autopsia/estatística & dados numéricos , Autopsia/tendências , Bélgica/epidemiologia , Encéfalo/diagnóstico por imagem , Causas de Morte , Feminino , Feto/patologia , Idade Gestacional , Coração/diagnóstico por imagem , Humanos , Imageamento por Ressonância Magnética/estatística & dados numéricos , Gravidez , Estudos Prospectivos , Sensibilidade e Especificidade , Coluna Vertebral/diagnóstico por imagem , Tórax/diagnóstico por imagem , Ultrassonografia/estatística & dados numéricos
6.
Ultrasound Obstet Gynecol ; 53(2): 229-238, 2019 02.
Artigo em Inglês | MEDLINE | ID: mdl-28782198

RESUMO

OBJECTIVE: To assess the diagnostic accuracy of postmortem ultrasound performed by operators blinded to prenatal findings and to invasive autopsy results in fetuses at different gestational ages and to investigate the effect of various parameters on its diagnostic success. METHODS: We performed postmortem two-dimensional ultrasound examination, blinded to clinical details, on 163 fetuses at 13-42 weeks' gestation. Logistic regression analysis was used to investigate the effect of: (i) gestational age at postmortem ultrasound, (ii) presence of maceration and (iii) mode of death, on whether the exam succeeded or failed to reach a diagnosis. In 123 cases in which invasive autopsy was available, the diagnostic accuracy of ultrasound in detecting major organ abnormalities was evaluated, using invasive autopsy as the gold standard. RESULTS: For the fetal brain, postmortem ultrasound exam was non-diagnostic in significantly more fetuses with maceration (39.5%; 17/43) vs those without maceration (20.0%; 24/120) (P = 0.013). For the fetal thorax, the exam was non-diagnostic in 34.1% (15/44) of fetuses < 20 weeks of gestation and in 10.9% (13/119) of fetuses ≥ 20 weeks (P < 0.001). For the heart and abdominal organs, there was no association between non-diagnostic postmortem ultrasound and the variables tested. For fetuses < 20 weeks, specificity of postmortem ultrasound examination was 83.3% for detection of anomalies of the brain, 68.6% for the thorax and 77.4% for the heart. For fetuses ≥ 20 weeks, sensitivity and specificity were, respectively, 61.9% and 74.2% for detection of anomalies of the brain, 29.5% and 87.0% for the thorax and 65.0% and 83.1% for the heart. For the fetal abdominal organs, sensitivity was 60.7% and specificity 75.8%, and postmortem ultrasound was particularly useful for detection of abnormalities of the kidneys, irrespective of gestational age. CONCLUSION: Although maceration may lead to failure of postmortem ultrasound examination in some cases, this technique achieves diagnostically acceptable levels of accuracy for fetal brain and abdominal organs, compared with conventional autopsy. It may therefore play a role as a first-line examination before other virtual autopsy techniques are indicated. Copyright © 2017 ISUOG. Published by John Wiley & Sons Ltd.


Assuntos
Autopsia/métodos , Morte Fetal/etiologia , Feto/diagnóstico por imagem , Ultrassonografia/métodos , Aborto Espontâneo/etiologia , Feminino , Idade Gestacional , Humanos , Gravidez , Estudos Prospectivos , Análise de Regressão , Sensibilidade e Especificidade , Método Simples-Cego
7.
Ultrasound Obstet Gynecol ; 52(2): 250-257, 2018 08.
Artigo em Inglês | MEDLINE | ID: mdl-28508549

RESUMO

OBJECTIVE: To evaluate the performance of a simple semi-automated method for estimation of fetal weight (EFW) using magnetic resonance imaging (MRI) as compared with two-dimensional (2D) ultrasound (US) for the prediction of large-for-dates neonates. METHODS: Data of two groups of women with singleton pregnancy between March 2011 and May 2016 were retrieved from our database and evaluated retrospectively: the first group included women who underwent US-EFW and MRI-EFW within 48 h before delivery and the second group included women who had these evaluations between 35 + 0 weeks and 37 + 6 weeks of gestation, more than 48 h before delivery. US-EFW was based on Hadlock et al. and MRI-EFW on the formula described by Baker et al. For MRI-EFW, planimetric measurement of the fetal body volume (FBV) was performed using a semi-automated method and the time required for measurement was noted. Outcome measure was the performance of MRI-EFW vs US-EFW in the prediction of large-for-dates neonates, both ≤ 48 h and > 48 h before delivery. Receiver-operating characteristics (ROC) curves for each method were compared using the DeLong method. RESULTS: Of the 270 women included in the first group, 48 (17.8%) newborns had birth weight ≥ 90th centile and 30 (11.1%) ≥ 95th centile. The second group included 83 women, and nine (10.8%) newborns had birth weight ≥ 95th centile. Median time needed for FBV planimetric measurements in all 353 fetuses was 3.5 (range, 1.5-5.5) min. The area under the ROC curve (AUC) for prediction of large-for-dates neonates by prenatal MRI performed within 48 h before delivery was significantly higher than that by US (for birth weight ≥ 90th centile, difference between AUCs = 0.085, standard error (SE) = 0.020, P < 0.001; for birth weight ≥ 95th centile, difference between AUCs = 0.036, SE = 0.014, P = 0.01). Similarly, MRI-EFW was better than US-EFW in predicting birth weight ≥ 95th centile when both examinations were performed > 48 h prior to delivery (difference between AUCs = 0.077, SE = 0.039, P = 0.045). CONCLUSION: MRI planimetry using our purpose-designed semi-automated method is not time-consuming. The predictive performance of MRI-EFW performed immediately prior to or remote from delivery is significantly better than that of US-EFW for the prediction of large-for-dates neonates. Copyright © 2017 ISUOG. Published by John Wiley & Sons Ltd.


Assuntos
Macrossomia Fetal/diagnóstico por imagem , Imageamento por Ressonância Magnética , Ultrassonografia Pré-Natal , Adulto , Peso ao Nascer , Feminino , Peso Fetal , Humanos , Recém-Nascido , Masculino , Valor Preditivo dos Testes , Gravidez , Resultado da Gravidez , Terceiro Trimestre da Gravidez , Estudos Retrospectivos
8.
Rev Med Liege ; 72(7-8): 336-339, 2017 Jul.
Artigo em Francês | MEDLINE | ID: mdl-28795544

RESUMO

Through the case report of a child who had had a congenital diaphragmatic hernia (cdh) and then relapsed 8 months after initial surgery, the various risk factors related to a cdh, its pre- and postnatal management as well as some long-term complications are discussed.


Par le biais du cas clinique d'un enfant qui a été opéré d'une hernie diaphragmatique congénitale (HDC) et qui a récidivé 8 mois plus tard, les différents facteurs de risques liés à la HDC, sa prise en charge ante et post-natale ainsi que quelques possibles complications à long terme sont discutés.


Assuntos
Hérnias Diafragmáticas Congênitas/diagnóstico por imagem , Hérnias Diafragmáticas Congênitas/cirurgia , Humanos , Lactente , Masculino , Recidiva
9.
Prog Urol ; 27(12): 603-608, 2017 Oct.
Artigo em Francês | MEDLINE | ID: mdl-28869171

RESUMO

INTRODUCTION: The etiology of the uretero-hydronephrosis in pregnancy is just hypothesis: hormonal or mechanical hypothesis, only investigated by echographic studies. MRI permits to visualize the entirety of the urinary tract, which can be helpful to find out a mechanical cause. METHODOLOGY: We have analysed the MRI of 100 asymptomatic pregnant women. We have determined the number and locations of the uretero-hydronephroses and researched whether there is any relationship between the uretero-hydronephrosis and certain abdominal structures. We focused on the psoas muscle and measured its depth, width and calculated its surface by a reproducible method. RESULTS: The analysis revealed that the uretero-hydronephrosis was predominantly at the right side (63%) and in the majority of the cases limited to the kidney (42%) and/or the proximal third of the ureter (42%). We were able to rule out some proposed etiologies: a compression of the ureter between the uterus and the iliac or ovarian vessels; a protective effect of the left intestinal structures. A link was observed between the psoas muscle and the physiological uretero-hydronephrosis: the ipsilateral psoas muscle seemed smaller in pregnant women presenting a uretero-hydronephrosis. CONCLUSION: We have highlighted a link between a physiological uretero-hydronephrosis during pregnancy and a lesser developped psoas muscle. The hypothesis proposed is that a smaller psoas muscle would have a less protective effect of the ureter due to a lesser development. This study offers a practical conclusion: a left sided uretero-hydronephrosis during pregnancy and/or including the entirety of the ureter is more probably a pathological hydronephrosis. LEVEL OF EVIDENCE: 4.


Assuntos
Hidronefrose/diagnóstico por imagem , Hidronefrose/etiologia , Imageamento por Ressonância Magnética , Complicações na Gravidez/diagnóstico por imagem , Complicações na Gravidez/etiologia , Feminino , Humanos , Hidronefrose/epidemiologia , Gravidez , Complicações na Gravidez/epidemiologia , Estudos Retrospectivos , Ureter
12.
Ultrasound Obstet Gynecol ; 46(2): 155-61, 2015 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-25487417

RESUMO

OBJECTIVE: To investigate the value of fetal stomach position in predicting postnatal outcome in left-sided congenital diaphragmatic hernia (CDH) with and without fetoscopic endoluminal tracheal occlusion (FETO). METHODS: This was a retrospective review of CDH cases that were expectantly managed or treated with FETO, assessed from May 2008 to October 2013, in which we graded, on a scale of 1-4, stomach position on the four-chamber view of the heart with respect to thoracic structures. Logistic regression analysis was used to investigate the effect of management center (Paris, Brussels, Barcelona, Milan), stomach grading, observed-to-expected lung area-to-head circumference ratio (O/E-LHR), gestational age at delivery, birth weight in expectantly managed CDH, gestational ages at FETO and at removal and period of tracheal occlusion, on postnatal survival in CDH cases treated with FETO. RESULTS: We identified 67 expectantly managed CDH cases and 47 CDH cases that were treated with FETO. In expectantly managed CDH, stomach position and O/E-LHR predicted postnatal survival independently. In CDH treated with FETO, stomach position and gestational age at delivery predicted postnatal survival independently. CONCLUSION: In left-sided CDH with or without FETO, stomach position is predictive of postnatal survival.


Assuntos
Fetoscopia/métodos , Feto/patologia , Hérnias Diafragmáticas Congênitas/diagnóstico por imagem , Estômago/diagnóstico por imagem , Oclusão com Balão/métodos , Feminino , Humanos , Valor Preditivo dos Testes , Gravidez , Estudos Retrospectivos , Ultrassonografia Pré-Natal
14.
Ultrasound Obstet Gynecol ; 42(4): 426-33, 2013 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-23671013

RESUMO

OBJECTIVE: To help elucidate the mechanism of action of the Arabin cervical pessary in pregnancies at high risk for preterm delivery. METHODS: Cervical length and uterocervical angle were evaluated in relation to gestational age in 198 pregnancies not at high risk for preterm birth that underwent clinical fetal magnetic resonance imaging (MRI). Additionally, in 73 singleton pregnancies at high risk for preterm birth, an Arabin cervical pessary was placed at 14-33 weeks' gestation. We performed MRI of the cervix immediately before and after placement and at monthly follow-up until removal of the pessary. In a subgroup of 54 pregnancies with a short cervix and pessary placement at 17-31 weeks' gestation, the uterocervical angle and cervical length at follow-up were compared with the preplacement values. RESULTS: In pregnancies not at high risk for preterm birth, the uterocervical angle did not vary, but cervical length showed a significant decrease with gestational age (r = -0.15, P < 0.05). Among the high-risk patients, the cervical pessary was successfully placed at first attempt in 60 (82.2%) and by the second attempt in 66 (90.4%), remaining well positioned until removal. In five patients we failed to place the pessary after two attempts, in one patient the pessary dislodged during follow-up and in one case the pessary was partly placed in the external cervical canal and triggered labor the next day. Among the subgroup of 54 patients, the median uterocervical angle immediately after pessary placement was significantly more acute than that prior to placement in the 46 (85.2%) who delivered after 34 weeks (132° vs 146°, P < 0.01), but was unchanged in the eight patients who delivered before 34 weeks (143° vs 152°, P > 0.05). CONCLUSION: In patients at high risk for preterm delivery, correct placement of the Arabin cervical pessary should be checked immediately; this can be performed quickly and easily using MRI. This study provides some evidence that, in singleton pregnancies with a short cervix, a cervical pessary delays birth through a mechanical effect on the uterocervical angle.


Assuntos
Pessários , Nascimento Prematuro/prevenção & controle , Doenças Uterinas/terapia , Adolescente , Adulto , Feminino , Humanos , Imageamento por Ressonância Magnética , Gravidez , Resultado da Gravidez , Gravidez de Alto Risco , Estudos Prospectivos , Estudos Retrospectivos , Adulto Jovem
15.
Ultrasound Obstet Gynecol ; 39(6): 673-8, 2012 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-22407748

RESUMO

OBJECTIVE: To ascertain whether high-field magnetic resonance imaging (MRI) allows accurate estimation of the weight of various fetal organs at postmortem before 20 weeks' gestation. METHODS: From 23 fetuses at 9-20 weeks, following termination of pregnancy or in-utero fetal death (IUFD), 207 assorted fetal organs were evaluated by high-field MRI at 9.4 T prior to conventional autopsy. Fetal organ density was calculated by correlating volume and weight at autopsy using linear regression analysis, and this was used to estimate fetal organ weight by MRI. The relative error in MRI estimation of organ weight was calculated as follows: (|MRI weight - autopsy weight|/autopsy weight) × 100 (%). Multiple regression analysis was used to investigate the effect on the relative error of MRI organ weight estimates of gestational age at TOP or delivery following IUFD, autopsy weight, fetal organ examined, IUFD and fetal maceration. RESULTS: Of the 207 organs evaluated, 133 (64%) were examined for fetal organ density and 155 (75%) for fetal organ weight. Fifty-two organs were excluded from our analysis; 41 of these were from fetuses with IUFD, with 39 organs macerated. In 32 cases, exclusion was due to an inability to assess the organ both on MRI and on conventional autopsy. Volume and weight at autopsy correlated significantly, following the linear equation: autopsy volume = (0.9947 × autopsy weight) - 4.7556, where autopsy volume is in mm(3) and weight is in mg (r = 0.99, P < 0.001). Overall the mean relative error in the MRI estimation of organ weight was 68%. Multiple regression analysis showed that the relative error in the MRI estimation of organ weight was significantly associated with gestational age at TOP or delivery following IUFD and fetal maceration, but not with autopsy weight, fetal organ examined or IUFD. In the subgroup of non-macerated organs and for fetuses above 14 weeks' gestation, the mean relative error in the MRI estimation of organ weight was 34%. CONCLUSION: In fetuses before 20 weeks' gestation, noninvasive estimation of organ weight is feasible using high-field MRI, but there is a mean overestimation. Limitations of the technique occur mainly in cases of small macerated fetuses before 14 weeks' gestation.


Assuntos
Encéfalo/patologia , Fígado/patologia , Pulmão/patologia , Imageamento por Ressonância Magnética , Aborto Induzido , Autopsia/métodos , Encéfalo/embriologia , Estudos de Viabilidade , Feminino , Morte Fetal , Idade Gestacional , Humanos , Fígado/embriologia , Pulmão/embriologia , Imageamento por Ressonância Magnética/métodos , Tamanho do Órgão , Gravidez , Estudos Prospectivos
16.
Ultrasound Obstet Gynecol ; 39(6): 679-84, 2012 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-22407734

RESUMO

OBJECTIVE: To determine the feasibility of postmortem computed tomographic (pm-CT) angiography for fetal heart evaluation. METHODS: Following termination of pregnancy (TOP) or intrauterine fetal death (IUFD) beyond 18 weeks' gestation, 33 fetuses were examined by pm-CT; in eight contrast medium was injected through the umbilical cord and in 25 contrast medium was injected directly into the heart. Logistic regression analysis was used to investigate the effect on the ability to visualize cardiac structures on pm-CT angiography of gestational age at TOP or delivery following IUFD, the time delay between fetal death and examination, the technique used for contrast-medium injection, the presence of cardiac abnormalities and whether or not there was IUFD. The diagnostic accuracy of pm-CT angiography for the evaluation of fetal cardiac structures was also evaluated. RESULTS: Cardiac anatomy including heart situs, the four-chamber view and great vessels could be visualized on pm-CT angiography in 29 out of 33 fetuses (87.9%). Logistic regression analysis showed that the ability to visualize cardiac structures on pm-CT angiography was positively correlated only with contrast medium injected directly into the heart. Twenty-five out of the 33 fetuses underwent conventional autopsy. There were five cases with suspected major cardiac abnormality at prenatal ultrasound and one with a minor cardiac abnormality. In one of these cases, severe leakage into the pleural cavity did not allow for visualization of any heart structure on pm-CT angiography and in another invasive autopsy was declined. In two of the remaining four cases, the findings on pm-CT angiography and invasive autopsy were in agreement, while in two a ventricular septal defect was found on invasive autopsy but not on pm-CT. None of the 27 cases with normal hearts was falsely classified as abnormal using pm-CT angiography. CONCLUSION: Pm-CT angiography by direct injection into the heart seems to be a feasible method for its evaluation. The extent to which such a technique could be used for the evaluation of congenital heart disease as an alternative to classical postmortem autopsy remains to be determined.


Assuntos
Autopsia/métodos , Angiografia Coronária , Morte Fetal/patologia , Coração Fetal/anormalidades , Coração Fetal/diagnóstico por imagem , Cardiopatias Congênitas/patologia , Tomografia Computadorizada por Raios X , Aborto Induzido , Meios de Contraste/administração & dosagem , Angiografia Coronária/métodos , Estudos de Viabilidade , Feminino , Morte Fetal/diagnóstico por imagem , Idade Gestacional , Cardiopatias Congênitas/diagnóstico por imagem , Cardiopatias Congênitas/embriologia , Humanos , Gravidez
17.
Ultrasound Obstet Gynecol ; 39(3): 322-9, 2012 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-21837757

RESUMO

OBJECTIVE: To evaluate prospectively the feasibility of magnetic resonance imaging (MRI) for assessment of the fetal heart for congenital heart disease (CHD). METHODS: This was a cross-sectional study, including 66 fetuses with a normal heart and 40 with CHD. The fetal heart was examined on MRI using axial steady-state free precession (SSFP) sequences. Regression analysis was used to investigate the effect on the ability to visualize cardiac anatomy of gestational age at examination, maternal body mass index, presence of fetal cardiac abnormality, fetal movements, fetal lie and twinning. The sensitivity and specificity of detecting cardiac defects were calculated. RESULTS: The four-chamber view was visualized in 98.1% of fetuses. The sensitivity of detecting a cardiac defect on the four-chamber view was 88% and the specificity 96%. The ability to visualize the left and right outflow tracts was only influenced by the presence of fetal movements: for the left outflow tract 94.4 vs. 50.0% visualization and for the right outflow tract 92.6 vs. 53.8% visualization without and with fetal movements, respectively. The sensitivity of detecting a cardiac defect of the left outflow tract was 63% and the specificity 100%, while sensitivity and specificity were 59 and 97%, respectively, for the right outflow tract. CONCLUSIONS: Despite the use of SSFP sequences, MRI in the fetal heart remains of limited value. It can only be used as a second-line approach for abnormalities of the four-chamber view suspected at prenatal ultrasound.


Assuntos
Coração Fetal/anatomia & histologia , Coração Fetal/patologia , Cardiopatias Congênitas/diagnóstico , Imageamento por Ressonância Magnética , Índice de Massa Corporal , Estudos Transversais , Feminino , Coração Fetal/fisiopatologia , Idade Gestacional , Cardiopatias Congênitas/patologia , Cardiopatias Congênitas/fisiopatologia , Humanos , Variações Dependentes do Observador , Gravidez , Primeiro Trimestre da Gravidez , Diagnóstico Pré-Natal , Estudos Prospectivos , Sensibilidade e Especificidade
18.
Ultrasound Obstet Gynecol ; 39(6): 659-65, 2012 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-21919100

RESUMO

OBJECTIVES: To compare prospectively maternal acceptance of fetal and neonatal virtuopsy with that of conventional autopsy and to determine the confidence with which magnetic resonance (MR) virtuopsy can be used to diagnose normality/abnormality of various fetal anatomical structures. METHODS: MR and/or computed tomography virtuopsy and conventional autopsy were offered to 96 women (102 fetuses/neonates) following termination of pregnancy (TOP), intrauterine fetal death (IUFD) or neonatal death. Multivariable logistic regression analysis was used to investigate the effect on maternal acceptance of virtuopsy and/or conventional autopsy of the age of the mother, gestational age at TOP or delivery after IUFD, order of pregnancy, parity, religion, type of caregiver obtaining consent and reason for death. When parents consented to both MR virtuopsy and conventional autopsy of fetuses ≥ 20 weeks of gestation or neonates, the confidence with which MR virtuopsy could be used to diagnose normality/abnormality of various anatomical structures was determined on a scale in which conventional autopsy was considered gold standard. On autopsy we classified fetuses/neonates as having either 'normal' or 'abnormal' anatomical structures; these groups were analyzed separately. At virtuopsy, we indicated confidence of diagnosis of normality/abnormality of every anatomical structure in each of these two groups defined at autopsy, using a scale from 0 (definitely abnormal) to 100 (definitely normal). RESULTS: Of the 96 women, 99% (n = 95) consented to virtuopsy and 61.5% (n = 59) to both conventional autopsy and virtuopsy; i.e. 36 (37.5%) consented to virtuopsy alone. Maternal acceptance of conventional autopsy was independently positively related to singleton pregnancy, non-Moslem mother, earlier gestation at TOP or delivery afer IUFD and a maternal-fetal medicine specialist obtaining consent. Thirty-three fetuses ≥ 20 weeks of gestation had both conventional autopsy and MR virtuopsy, of which 19 had a full autopsy including the brain. In fetuses with normal anatomical structures at conventional autopsy, MR virtuopsy was associated with high diagnostic confidence (scores > 80) for the brain, skeleton, thoracic organs except the heart, abdominal organs except the pancreas, ureters, bladder and genitals. In fetuses with abnormal anatomical structures at autopsy, MR virtuopsy detected the anomalies with high confidence (scores < 20) for these same anatomical structures. However, in three cases, virtuopsy diagnosed brain anomalies additional to those observed at conventional autopsy. CONCLUSION: MR virtuopsy is accepted by nearly all mothers while conventional autopsy is accepted by about two-thirds of mothers, in whom refusal depends mainly on factors over which we have no control. Although conventional autopsy remains the gold standard, the high acceptance of virtuopsy makes it an acceptable alternative when the former is declined.


Assuntos
Aborto Induzido , Autopsia/métodos , Anormalidades Congênitas/diagnóstico , Doenças Fetais/diagnóstico , Imageamento por Ressonância Magnética/métodos , Mães/psicologia , Natimorto , Tomografia Computadorizada por Raios X/métodos , Aborto Induzido/psicologia , Adulto , Autopsia/instrumentação , Causas de Morte , Anormalidades Congênitas/mortalidade , Anormalidades Congênitas/psicologia , Feminino , Doenças Fetais/mortalidade , Doenças Fetais/psicologia , Idade Gestacional , Humanos , Recém-Nascido , Modelos Logísticos , Idade Materna , Análise Multivariada , Paridade , Aceitação pelo Paciente de Cuidados de Saúde , Gravidez , Estudos Prospectivos , Religião , Reprodutibilidade dos Testes , Natimorto/psicologia
19.
Ultrasound Obstet Gynecol ; 40(4): 437-44, 2012 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-22605566

RESUMO

OBJECTIVES: To compare the diagnostic usefulness of high-field with low-field magnetic resonance imaging (MRI) and stereomicroscopic autopsy for examination of the heart in fetuses at or under 20 weeks' gestation. METHODS: Prior to invasive stereomicroscopic autopsy, MRI scans at 9.4, 3.0 and 1.5 T were performed on 24 fetuses between 11 and 20 weeks' gestation, including 10 fetuses with cardiac abnormalities. The ability to visualize different heart structures was evaluated according to the different field strength MRI magnets used and gestational age at examination. RESULTS: On 1.5- and 3.0-T MRI, only the heart situs and four-chamber view could be visualized consistently (in 75% or more of cases) when the fetus was beyond 16 weeks' gestation, but other heart structures could not be visualized for fetuses at any gestational age. In contrast, using high-field MRI at 9.4 T, the heart situs, four-chamber view and the outflow tracts could be visualized in all fetuses irrespective of gestational age. Using high-field MRI, the sensitivity for detecting an abnormality of the four-chamber view was 66.7% (95% CI, 30.1-92.1%) with a specificity of 80.0% (95% CI, 51.9-95.4%). For abnormalities of the outflow tracts, sensitivity was 75.0% (95% CI, 20.3-95.9%) and specificity 100.0% (95% CI, 83.3-100.0%). Eight fetuses out of 10 with congenital heart disease (CHD) were classified as having major CHD. High-field MRI at 9.4 T was able to identify seven out of the eight cases of major CHD. CONCLUSION: High-field MRI at 9.4 T seems to be an acceptable alternative approach to invasive stereomicroscopic autopsy for fetuses with CHD at or below 20 weeks' gestation.


Assuntos
Autopsia/métodos , Coração Fetal/patologia , Cardiopatias Congênitas/patologia , Microscopia/métodos , Feminino , Morte Fetal , Coração Fetal/anormalidades , Humanos , Imageamento por Ressonância Magnética , Tamanho do Órgão , Gravidez
20.
Rev Med Brux ; 33(4): 246-53, 2012 Sep.
Artigo em Francês | MEDLINE | ID: mdl-23091928

RESUMO

Circulating analytes used in the exploration of thyroid function are TSH and free thyroid hormones (FT4 and FT3). TSH is used as first line analysis in diagnosis because a normal value excludes almost always a thyroid dysfunction. However in the follow up of a treatment for hypo- or hyperthyroidism, free hormones are to be determined since TSH reaction is delayed and does not reflect precisely the restoration of euthyroidism. The measurement of anti-thyroperoxidase antibodies (anti-TPO) will show the presence of an autoimmune thyroiditis and that of thyroid stimulating antibodies (TSI) will establish the diagnosis of Graves' disease. The measurement of circulating thyroglobulin has no place in the diagnostic of thyroid dysfunction nor in the evaluation of a goitre but it is now the golden standard in the follow up of patients with a differentiated thyroid cancer after surgery and radioiodine ablation in patients without antithyroglobulin antibodies. Echography is the first line examination to evaluate thyroid morphology. It shows tiny thyroid nodules and gives precious informations on their structure, as well as paremchymatous diffuse abnormalities associated with thyroiditis. Thyroid scintigraphy with 99mTc allows establishing the functional characteristics of thyroid nodules (warm or cold) and to precise the origin of a thyrotoxicosis (autonomous toxic nodule vs Graves-Basedow, sub acute or silent thyroiditis). Whole body scintigraphy is mandatory after radioiodine treatment with 131I in order to visualize possible metastasis and establish their avidity for iodine.


Assuntos
Diagnóstico por Imagem/métodos , Testes Hematológicos/métodos , Doenças da Glândula Tireoide/diagnóstico , Autoanticorpos/análise , Autoanticorpos/sangue , Diagnóstico por Imagem/estatística & dados numéricos , Testes Hematológicos/estatística & dados numéricos , Humanos , Valor Preditivo dos Testes , Radiografia , Cintilografia , Tireoglobulina/análise , Tireoglobulina/sangue , Doenças da Glândula Tireoide/sangue , Glândula Tireoide/anormalidades , Glândula Tireoide/diagnóstico por imagem , Ultrassonografia
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA