Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 4 de 4
Filtrar
1.
J Cardiovasc Electrophysiol ; 33(5): 874-882, 2022 05.
Artigo em Inglês | MEDLINE | ID: mdl-35262242

RESUMO

INTRODUCTION: Lesion Index (LSI) has been developed to predict lesion efficacy during radiofrequency (RF) catheter ablation. However, its value in predicting lesions size has still to be established. The aim of our study was to assess the lesions size reproducibility for prespecified values of LSI reached during RF delivery in an in vivo beating heart. METHODS: Ablation lesions were created with different values of LSI in seven domestic pigs by means of a contact force-sensing catheter (TactiCathTM , Abbott). Lesions were identified during RF delivery by means of a three-dimensional mapping system (EnSiteTM Precision, Abbott) and measured after heart explantation. Histology was carried out after gross examination on the first three lesions to confirm the accuracy of the macroscopic evaluation. RESULTS: A total of 64 myocardial lesions were created. Thirty-nine lesions were excluded from the analysis for the following reasons: histological confirmation of macroscopic lesion measurement (n = 3), transmurality (n = 24), unfavorable anatomic position (n = 10), not macroscopically identifiable (n = 2). In a final set of 25 nontransmural lesions, injury width and depth were, respectively, 4.6 ± 0.6 and 2.6 ± 0.8 mm for LSI = 4, 7.3 ± 0.8 and 4.7 ± 0.6 mm for LSI = 5, and 8.6 ± 1.2 and 7.2 ± 1.1 mm for LSI = 6. A strong linear correlation was observed between LSI and lesion width (r = .87, p < .00001) and depth (r = .89, p < .00001). Multiple linear regression analysis identified LSI as the only ablation parameter that significantly predicted lesion width (p < .001) and depth (p < .001). CONCLUSION: In our in vivo study, LSI proved highly predictive of lesion size and depth.


Assuntos
Ablação por Cateter , Animais , Ablação por Cateter/efeitos adversos , Ablação por Cateter/métodos , Catéteres , Coração , Humanos , Reprodutibilidade dos Testes , Sus scrofa , Suínos
2.
Pacing Clin Electrophysiol ; 41(2): 106-113, 2018 02.
Artigo em Inglês | MEDLINE | ID: mdl-29222865

RESUMO

BACKGROUND: Multipoint left ventricular (LV) pacing (MultiPoint™ Pacing [MPP], Abbott, Sylmar, CA, USA) improves the response rate to cardiac resynchronization therapy (CRT). We evaluated the feasibility of noninvasive radial artery tonometry (RAT) to characterize arterial pressure morphology changes (pre-ejection period [PEP] and ejection duration [ED]) between conventional CRT and MPP pacing interventions. METHODS: Patients with a MPP-enabled CRT device (Quadra Assura MP™, Abbott) underwent noninvasive RAT assessment (SphygmoCor CVMS, AtCor Medical Inc., Itasca, IL, USA) at 3-6 months after implantation. A pacing protocol was performed in a randomized order including one optimized conventional biventricular CRT (CONV) configuration using the distal electrode and five MPP configurations. The PEP, ED, and PEP/ED ratio were determined for each intervention from the RAT pressure waveform and electrocardiogram. RESULTS: Pressure waveforms were successfully recorded in 19 patients (89% male, QRS 147 ± 16 ms, 63% ischemic). In 17/19 (89%) patients, at least one MPP intervention resulted in improved PEP, ED, and PEP/ED compared to CONV. The MPP intervention with greatest separation of LV cathodes and minimum intra-LV delay significantly improved PEP (mean PEP -15 ± 33% vs -8 ± 32% [CONV], P = 0.04) and ED (mean ED +8 ± 8% [MPP] vs +4 ± 7% [CONV], P = 0.02), and PEP/ED (-0.07 ± 0.14 [MPP] vs -0.04 ± 0.13 [CONV], P = 0.02) compared with CONV. CONCLUSIONS: Noninvasive RAT efficiently characterizes changes in PEP and ED between CONV and MPP interventions. MPP configurations using the widest separation among LV cathodes and minimum intra-LV delay may significantly improve RAT-derived parameters as compared to conventional CRT.


Assuntos
Hemodinâmica/fisiologia , Manometria/métodos , Marca-Passo Artificial , Artéria Radial/fisiologia , Idoso , Dispositivos de Terapia de Ressincronização Cardíaca , Ecocardiografia , Eletrocardiografia , Desenho de Equipamento , Estudos de Viabilidade , Feminino , Humanos , Masculino
3.
J Interv Card Electrophysiol ; 54(2): 141-149, 2019 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-30483980

RESUMO

PURPOSE: Cardiac resynchronization therapy (CRT) with multipoint left ventricular (LV) pacing (MultiPoint™ Pacing [MPP]) improves long-term LV reverse remodeling, though questions persist about how to program LV pacing vectors and delays. We evaluated if an empirical method of programming MPP vectors and delays between pacing pulses improved CRT response similar to pressure-volume loop (PVL) optimized MPP programming. METHODS: Patients undergoing CRT implant (Quadra Assura MP™ CRT-D and Quartet™ LV lead) received MPP with programmed settings optimized either by PVL measurements at implant (PVL-OPT group) or empirically determined by maximizing the spatial separation between the two cathodes and minimal delays between the three ventricular pacing pulses (MAX-SEP group). CRT response was prospectively defined as a reduction in end-systolic volume (ESV) of ≥ 15% relative to baseline at 6 months as determined by a blinded observer. RESULTS: Patient characteristics at baseline (NYHA II-III, ejection fraction [EF] 27 ± 6%, QRS 151 ± 17 ms) were not significantly different between the PVL-OPT (n = 27) and MAX-SEP (n = 26) groups. During the follow-up period, there were no differences in the number of patients requiring reprogramming due to phrenic nerve stimulation or a high threshold for PVL-OPT vs. MAX-SEP (5/27 [19%] vs. 7/26 [27%], p = 0.53). After 6 months, ESV reduction, EF increase, and CRT response rate (RR) were similar for PVL-OPT vs. MAX-SEP (ESV - 20 ± 11 vs. - 22 ± 11%, p = 0.59; EF + 10 ± 4 vs. + 9 ± 7%, p = 0.53; RR 20/27 [74%] vs. 21/26 [81%], p = 0.74), while fewer patients in the PVL-OPT group experienced NYHA class reduction ≥ 2 (4/27 [15%] vs.15/26 [58%], p = 0.002). CONCLUSIONS: Both evaluated methods of MPP programming resulted in similar CRT outcomes. Empirical MPP programming by maximum spatial separation of LV cathodes may be an effective, simple, and non-invasive alternative to pressure-volume optimization.


Assuntos
Estimulação Cardíaca Artificial/métodos , Ecocardiografia/métodos , Insuficiência Cardíaca/terapia , Ventrículos do Coração/diagnóstico por imagem , Remodelação Ventricular/fisiologia , Idoso , Terapia de Ressincronização Cardíaca/métodos , Estudos de Coortes , Feminino , Insuficiência Cardíaca/diagnóstico , Humanos , Masculino , Pessoa de Meia-Idade , Prognóstico , Estudos Prospectivos , Medição de Risco , Volume Sistólico/fisiologia , Fatores de Tempo , Resultado do Tratamento
4.
Am J Cardiol ; 119(9): 1382-1386, 2017 May 01.
Artigo em Inglês | MEDLINE | ID: mdl-28258730

RESUMO

Catheter ablation (CA) is a procedure commonly used to restore sinus rhythm in patients with atrial fibrillation (AF). However, AF recurrence after CA remains a relevant clinical issue. We tested the effects of an oral antioxidant treatment (alpha lipoic acid [ALA]) on AF recurrence post-CA. Patients with paroxysmal AF have been enrolled in a randomized, prospective, double-blind, controlled placebo trial. After CA, patients have been randomly assigned to receive ALA oral supplementation (ALA group) or placebo (control group) and evaluated at baseline and after a 12-month follow-up: 73 patients completed the 12-month follow-up (ALA: 33 and control: 40). No significant difference has been detected between the 2 groups at baseline. Strikingly, 1 year after CA, ALA therapy significantly reduced serum markers of inflammation. However, there was no significant difference in AF recurrence events at follow-up comparing ALA with placebo group. Multivariate analysis revealed that the only independent prognostic risk factor for AF recurrence after CA is age. In conclusion, ALA therapy reduces serum levels of common markers of inflammation in ablated patients. Nevertheless, ALA does not prevent AF recurrence after an ablative treatment.


Assuntos
Antioxidantes/uso terapêutico , Fibrilação Atrial/prevenção & controle , Ablação por Cateter , Cuidados Pós-Operatórios , Ácido Tióctico/uso terapêutico , Idoso , Fibrilação Atrial/imunologia , Fibrilação Atrial/metabolismo , Fibrilação Atrial/cirurgia , Biomarcadores/metabolismo , Glicemia/metabolismo , Proteína C-Reativa/metabolismo , HDL-Colesterol/metabolismo , LDL-Colesterol/metabolismo , Citocinas/imunologia , Método Duplo-Cego , Feminino , Humanos , Interleucina-10/imunologia , Interleucina-6/imunologia , Interleucina-8/imunologia , Masculino , Pessoa de Meia-Idade , Peptídeo Natriurético Encefálico/metabolismo , Fragmentos de Peptídeos/metabolismo , Ácido Peroxinitroso/metabolismo , Recidiva , Resultado do Tratamento , Triglicerídeos/metabolismo , Fator de Necrose Tumoral alfa/imunologia , Tirosina/análogos & derivados , Tirosina/imunologia
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA