Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 88
Filtrar
Mais filtros

Base de dados
País/Região como assunto
Tipo de documento
Intervalo de ano de publicação
1.
Am J Respir Crit Care Med ; 209(5): 517-528, 2024 Mar 01.
Artigo em Inglês | MEDLINE | ID: mdl-38259196

RESUMO

Rationale: Sepsis management relies on fluid resuscitation avoiding fluid overload and its related organ congestion. Objectives: To explore the influence of country income group on risk-benefit balance of fluid management strategies in sepsis. Methods: We searched e-databases for all randomized controlled trials on fluid resuscitation in patients with sepsis or septic shock up to January 2023, excluding studies on hypertonic fluids, colloids, and depletion-based interventions. The effect of fluid strategies (higher versus lower volumes) on mortality was analyzed per income group (i.e., low- and middle-income countries [LMICs] or high-income countries [HICs]). Measurements and Main Results: Twenty-nine studies (11,798 patients) were included in the meta-analysis. There was a numerically higher mortality in studies of LMICs as compared with those of HICs: median, 37% (interquartile range [IQR]: 26-41) versus 29% (IQR: 17-38; P = 0.06). Income group significantly interacted with the effect of fluid volume on mortality: Higher fluid volume was associated with higher mortality in LMICs but not in HICs: odds ratio (OR), 1.47; 95% confidence interval (95% CI): 1.14-1.90 versus 1.00 (95% CI: 0.87-1.16), P = 0.01 for subgroup differences. Higher fluid volume was associated with increased need for mechanical ventilation in LMICs (OR, 1.24 [95% CI: 1.08-1.43]) but not in HICs (OR, 1.02 [95% CI: 0.80-1.29]). Self-reported access to mechanical ventilation also significantly influenced the effect of fluid volume on mortality, which increased with higher volumes only in settings with limited access to mechanical ventilation (OR: 1.45 [95% CI: 1.09-1.93] vs. 1.09 [95% CI: 0.93-1.28], P = 0.02 for subgroup differences). Conclusions: In sepsis trials, the effect of fluid resuscitation approach differed by setting, with higher volume of fluid resuscitation associated with increased mortality in LMICs and in settings with restricted access to mechanical ventilation. The precise reason for these differences is unclear and may be attributable in part to resource constraints, participant variation between trials, or other unmeasured factors.


Assuntos
Sepse , Choque Séptico , Humanos , Bases de Dados Factuais , Hidratação , Renda , Sepse/terapia , Ensaios Clínicos Controlados Aleatórios como Assunto
2.
Crit Care ; 28(1): 174, 2024 05 23.
Artigo em Inglês | MEDLINE | ID: mdl-38783367

RESUMO

BACKGROUND: Dyspnea is a key symptom of de novo acute hypoxemic respiratory failure. This study explores dyspnea and its association with intubation and mortality in this population. METHODS: This was a secondary analysis of a multicenter, randomized, controlled trial. Dyspnea was quantified by a visual analog scale (dyspnea-VAS) from zero to 100 mm. Dyspnea was measured in 259 of the 310 patients included. Factors associated with intubation were assessed with a competing risks model taking into account ICU discharge. The Cox model was used to evaluate factors associated with 90-day mortality. RESULTS: At baseline (randomization in the parent trial), median dyspnea-VAS was 46 (interquartile range, 16-65) mm and was ≥ 40 mm in 146 patients (56%). The intubation rate was 45%. Baseline variables independently associated with intubation were moderate (dyspnea-VAS 40-64 mm) and severe (dyspnea-VAS ≥ 65 mm) dyspnea at baseline (sHR 1.96 and 2.61, p = 0.023), systolic arterial pressure (sHR 2.56, p < 0.001), heart rate (sHR 1.94, p = 0.02) and PaO2/FiO2 (sHR 0.34, p = 0.028). 90-day mortality was 20%. The cumulative probability of survival was lower in patients with baseline dyspnea-VAS ≥ 40 mm (logrank test, p = 0.049). Variables independently associated with mortality were SAPS 2 ≥ 25 (p < 0.001), moderate-to-severe dyspnea at baseline (p = 0.073), PaO2/FiO2 (p = 0.118), and treatment arm (p = 0.046). CONCLUSIONS: In patients admitted to the ICU for de novo acute hypoxemic respiratory failure, dyspnea is associated with a higher risk of intubation and with a higher mortality. TRIAL REGISTRATION: clinicaltrials.gov Identifier # NCT01320384.


Assuntos
Dispneia , Insuficiência Respiratória , Humanos , Dispneia/etiologia , Masculino , Feminino , Pessoa de Meia-Idade , Idoso , Insuficiência Respiratória/terapia , Insuficiência Respiratória/mortalidade , Insuficiência Respiratória/etiologia , Insuficiência Respiratória/fisiopatologia , Intubação Intratraqueal/estatística & dados numéricos , Intubação Intratraqueal/métodos , Hipóxia/terapia , Hipóxia/fisiopatologia , Hipóxia/complicações , Unidades de Terapia Intensiva/estatística & dados numéricos , Unidades de Terapia Intensiva/organização & administração , Modelos de Riscos Proporcionais
3.
Am J Respir Crit Care Med ; 207(9): 1126-1133, 2023 05 01.
Artigo em Inglês | MEDLINE | ID: mdl-36716353

RESUMO

The COVID-19 crisis was characterized by a massive need for respiratory support, which has unfortunately not been met globally. This situation mimicked those which gave rise to critical care in the past. Since the polio epidemic in the 50's, the technological evolution of respiratory support has enabled health professionals to save the lives of critically-ill patients worldwide every year. However, much of the current innovation work has turned around developing sophisticated, complex, and high-cost standards and approaches whose resilience is still questionable upon facing constrained environments or contexts, as seen in resuscitation work outside intensive care units, during pandemics, or in low-income countries. Ventilatory support is an essential life-saving tool for patients with respiratory distress. It requires an oxygen source combined to a ventilatory assistance device, an adequate monitoring system, and properly trained caregivers to operate it. Each of these elements can be subject to critical constraints, which we can no longer ignore. The innovation process should incorporate them as a prima materia, whilst focusing on the core need of the field using the concept of frugal innovation. Having a universal access to oxygen and respiratory support, irrespective of the context and constraints, necessitates: i) developing cost-effective, energy-efficient, and maintenance-free oxygen generation devices; ii) improving the design of non-invasive respiratory devices (for example, with oxygen saving properties); iii) conceiving fully frugal ventilators and universal monitoring systems; iv) broadening ventilation expertise by developing end-user training programs in ventilator assistance. The frugal innovation approach may give rise to a more resilient and inclusive critical care system. This paradigm shift is essential for the current and future challenges.


Assuntos
COVID-19 , Humanos , COVID-19/epidemiologia , Pandemias , Cuidados Críticos , Unidades de Terapia Intensiva , Oxigênio
4.
Aust Crit Care ; 37(4): 600-605, 2024 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-38267269

RESUMO

BACKGROUND: Tidal volume (Vt) delivery during mechanical ventilation is influenced by gas compression, humidity, and temperature. OBJECTIVES: This bench study aimed at assessing the accuracy of Vt delivery by paediatric intensive care ventilators according to the humidification system. Secondary objectives were to assess the following: (i) the accuracy of Vt delivery in ventilators with an integrated Y-piece pneumotachograph and (ii) the ability of ventilators to deliver and maintain a preset positive end-expiratory pressure. METHODS: Six latest-generation intensive care ventilators equipped with a paediatric mode were tested on the ASL5000 test lung in four simulated paediatric bench models (full-term neonate, infant, preschool-age chile, and school-age child), under volume-controlled mode with a heated humidifier (HH) or a heat moisture exchanger, with various loading conditions. Three ventilators equipped with a Y-piece pneumotachograph were tested with or without the pneumotachograph in the neonatal and infant models. "Accurate Vt" delivery was defined as a volume error (percentage of the preset Vt under body temperature and pressure and saturated water vapour conditions) being ≤10 % of the absolute preset value. RESULTS: Vt accuracy varied significantly across ventilators but was acceptable in almost all the ventilators and all the models, except the neonatal model. The humidification system had an impact on Vt delivery in the majority of the tested conditions (p < 0.05). The use of an HH was associated with a better Vt accuracy in four ventilators (V500, V800, R860, and ServoU) and allowed to achieve an acceptable level of volume error in the neonatal model as compared to the use of heat moisture exchanger. The use of an integrated pneumotachograph was associated with lower volume error in only one ventilator (p < 0.01). All the tested ventilators were able to maintain adequate positive end-expiratory pressure levels. CONCLUSION: The humidification system affects Vt accuracy of paediatric intensive care ventilators, especially in the youngest patients for whom the HH should be preferred.


Assuntos
Volume de Ventilação Pulmonar , Ventiladores Mecânicos , Humanos , Recém-Nascido , Lactente , Desenho de Equipamento , Respiração Artificial , Criança , Unidades de Terapia Intensiva Pediátrica , Pré-Escolar , Umidade
5.
Crit Care ; 27(1): 273, 2023 07 07.
Artigo em Inglês | MEDLINE | ID: mdl-37420282

RESUMO

BACKGROUND: Airway opening pressure (AOP) detection and measurement are essential for assessing respiratory mechanics and adapting ventilation. We propose a novel approach for AOP assessment during volume assist control ventilation at a usual constant-flow rate of 60 L/min. OBJECTIVES: To validate the conductive pressure (Pcond) method, which compare the Pcond-defined on the airway pressure waveform as the difference between the airway pressure level at which an abrupt change in slope occurs at the beginning of insufflation and PEEP-to resistive pressure for AOP detection and measurement, and to compare its respiratory and hemodynamic tolerance to the standard low-flow insufflation method. METHODS: The proof-of-concept of the Pcond method was assessed on mechanical (lung simulator) and physiological (cadavers) bench models. Its diagnostic performance was evaluated in 213 patients, using the standard low-flow insufflation method as a reference. In 45 patients, the respiratory and hemodynamic tolerance of the Pcond method was compared with the standard low-flow method. MEASUREMENTS AND MAIN RESULTS: Bench assessments validated the Pcond method proof-of-concept. Sensitivity and specificity of the Pcond method for AOP detection were 93% and 91%, respectively. AOP obtained by Pcond and standard low-flow methods strongly correlated (r = 0.84, p < 0.001). Changes in SpO2 were significantly lower during Pcond than during standard method (p < 0.001). CONCLUSION: Determination of Pcond during constant-flow assist control ventilation may permit to easily and safely detect and measure AOP.


Assuntos
Insuflação , Humanos , Insuflação/métodos , Pulmão , Fenômenos Fisiológicos Respiratórios , Mecânica Respiratória , Respiração Artificial/métodos
6.
Crit Care ; 27(1): 176, 2023 05 08.
Artigo em Inglês | MEDLINE | ID: mdl-37158963

RESUMO

INTRODUCTION: Electrical impedance tomography (EIT) can be used to assess ventilation/perfusion (V/Q) mismatch within the lungs. Several methods have been proposed, some of them neglecting the absolute value of alveolar ventilation (VA) and cardiac output (QC). Whether this omission results in acceptable bias is unknown. METHODS: Pixel-level V/Q maps of 25 ARDS patients were computed once considering (absolute V/Q map) and once neglecting (relative V/Q map) the value of QC and VA. Previously published indices of V/Q mismatch were computed using absolute V/Q maps and relative V/Q maps. Indices computed with relative V/Q maps were compared to their counterparts computed using absolute V/Q maps. RESULTS: Among 21 patients with ratio of alveolar ventilation to cardiac output (VA/QC) > 1, relative shunt fraction was significantly higher than absolute shunt fraction [37% (24-66) vs 19% (11-46), respectively, p < 0.001], while relative dead space fraction was significantly lower than absolute dead space fraction [40% (22-49) vs 58% (46-84), respectively, p < 0.001]. Relative wasted ventilation was significantly lower than the absolute wasted ventilation [16% (11-27) vs 29% (19-35), respectively, p < 0.001], while relative wasted perfusion was significantly higher than absolute wasted perfusion [18% (11-23) vs 11% (7-19), respectively, p < 0.001]. The opposite findings were retrieved in the four patients with VA/QC < 1. CONCLUSION: Neglecting cardiac output and alveolar ventilation when assessing V/Q mismatch indices using EIT in ARDS patients results in significant bias, whose direction depends on the VA/QC ratio value.


Assuntos
Respiração , Síndrome do Desconforto Respiratório , Humanos , Impedância Elétrica , Perfusão , Tomografia Computadorizada por Raios X , Débito Cardíaco , Pulmão
7.
Crit Care ; 27(1): 262, 2023 07 04.
Artigo em Inglês | MEDLINE | ID: mdl-37403149

RESUMO

BACKGROUND: Several noninvasive ventilatory supports rely in their design on high oxygen consumption which may precipitate oxygen shortage, as experienced during the COVID-19 pandemic. In this bench-to-bedside study, we assessed the performance of a new continuous positive airway pressure (CPAP) device integrating a large reservoir ("Bag-CPAP") designed to minimize oxygen consumption, and compared it with other CPAP devices. METHODS: First, a bench study compared the performances of Bag-CPAP and four CPAP devices with an intensive care unit ventilator. Two FiO2 targets (40-60% and 80-100%) at a predefined positive end expiratory pressure (PEEP) level between 5 and 10 cm H2O were tested and fraction of inspired oxygen (FiO2) and oxygen consumption were measured. Device-imposed work of breathing (WOB) was also evaluated. Second, an observational clinical study evaluated the new CPAP in 20 adult patients with acute respiratory failure in two hospitals in France. Actual FiO2, PEEP, peripheral oxygen saturation, respiratory rate, and dyspnea score were assessed. RESULTS: All six systems tested in the bench study reached the minimal FiO2 target of 40% and four reached at least 80% FiO2 while maintaining PEEP in the predefined range. Device-delivered FiO2/consumed oxygen ratio was the highest with the new reservoir-based CPAP irrespective of FiO2 target. WOB induced by the device was higher with Bag-CPAP. In the clinical study, Bag-CPAP was well tolerated and could reach high (> 90%) and moderate (> 50%) FiO2 with an oxygen flow rate of 15 [15-16] and 8 [7-9] L/min, respectively. Dyspnea score improved significantly after introduction of Bag-CPAP, and SpO2 increased. CONCLUSIONS: In vitro, Bag-CPAP exhibited the highest oxygen saving properties albeit had increased WOB. It was well accepted clinically and reduced dyspnea. Bag-CPAP may be useful to treat patients with acute respiratory failure in the field, especially when facing constraints in oxygen delivery.


Assuntos
COVID-19 , Insuficiência Respiratória , Adulto , Humanos , Pressão Positiva Contínua nas Vias Aéreas , COVID-19/terapia , Dispneia , Oxigênio , Consumo de Oxigênio , Pandemias , Insuficiência Respiratória/terapia
8.
Crit Care ; 26(1): 185, 2022 06 20.
Artigo em Inglês | MEDLINE | ID: mdl-35725498

RESUMO

BACKGROUND: Whether targeting the driving pressure (∆P) when adjusting the tidal volume in mechanically ventilated patients with the acute respiratory distress syndrome (ARDS) may decrease the risk of ventilator-induced lung injury remains a matter of research. In this study, we assessed the effect of a ∆P-guided ventilation on the mechanical power. METHODS: We prospectively included adult patients with moderate-to-severe ARDS. Positive end expiratory pressure was set by the attending physician and kept constant during the study. Tidal volume was first adjusted to target 6 ml/kg of predicted body weight (PBW-guided ventilation) and subsequently modified within a range from 4 to 10 ml/kg PBW to target a ∆P between 12 and 14 cm H2O. The respiratory rate was then re-adjusted within a range from 12 to 40 breaths/min until EtCO2 returned to its baseline value (∆P-guided ventilation). Mechanical power was computed at each step. RESULTS: Fifty-one patients were included between December 2019 and May 2021. ∆P-guided ventilation was feasible in all but one patient. The ∆P during PBW-guided ventilation was already within the target range of ∆P-guided ventilation in five (10%) patients, above in nine (18%) and below in 36 (72%). The change from PBW- to ∆P-guided ventilation was thus accompanied by an overall increase in tidal volume from 6.1 mL/kg PBW [5.9-6.2] to 7.7 ml/kg PBW [6.2-8.7], while respiratory rate was decreased from 29 breaths/min [26-32] to 21 breaths/min [16-28] (p < 0.001 for all comparisons). ∆P-guided ventilation was accompanied by a significant decrease in mechanical power from 31.5 J/min [28-35.7] to 28.8 J/min [24.6-32.6] (p < 0.001), representing a relative decrease of 7% [0-16]. With ∆P-guided ventilation, the PaO2/FiO2 ratio increased and the ventilatory ratio decreased. CONCLUSION: As compared to a conventional PBW-guided ventilation, a ∆P-guided ventilation strategy targeting a ∆P between 12 and 14 cm H2O required to change the tidal volume in 90% of the patients. Such ∆P-guided ventilation significantly reduced the mechanical power. Whether this physiological observation could be associated with clinical benefit should be assessed in clinical trials.


Assuntos
Síndrome do Desconforto Respiratório , Adulto , Peso Corporal , Humanos , Pulmão , Respiração com Pressão Positiva , Respiração Artificial , Síndrome do Desconforto Respiratório/terapia , Volume de Ventilação Pulmonar/fisiologia
9.
Crit Care ; 26(1): 350, 2022 11 12.
Artigo em Inglês | MEDLINE | ID: mdl-36371306

RESUMO

Spontaneous pneumomediastinum (SP) has been described early during the COVID-19 pandemic in large series of patients with severe pneumonia, but most patients were receiving invasive mechanical ventilation (IMV) at the time of SP diagnosis. In this retrospective multicenter observational study, we aimed at describing the prevalence and outcomes of SP during severe COVID-19 with pneumonia before any IMV, to rule out mechanisms induced by IMV in the development of pneumomediastinum.Among 549 patients, 21 patients (4%) developed a SP while receiving non-invasive respiratory support, after a median of 6 days [4-12] from ICU admission. The proportion of patients requiring IMV was similar. However, the time to tracheal intubation was longer in patients with SP (6 days [5-13] vs. 2 days [1-4]; P = 0.00002), with a higher first-line use of non-invasive ventilation (n = 11; 52% vs. n = 150; 28%; P = 0.02). The 21 patients who developed a SP had persisting signs of severe lung disease and respiratory failure with lower ROX index between ICU admission and occurrence of SP (3.94 [3.15-5.55] at admission vs. 3.25 [2.73-4.02] the day preceding SP; P = 0.1), which may underline potential indirect signals of Patient-self inflicted lung injury (P-SILI).In this series of critically ill COVID-19 patients, the prevalence of SP without IMV was not uncommon, affecting 4% of patients. They received more often vasopressors and had a longer ICU length of stay, as compared with their counterparts. One pathophysiological mechanism may potentially be carried out by P-SILI related to a prolonged respiratory failure, as underlined by a delayed use of IMV and the evolution of the ROX index between ICU admission and the day preceding SP.


Assuntos
COVID-19 , Enfisema Mediastínico , Insuficiência Respiratória , Humanos , COVID-19/complicações , COVID-19/terapia , Pandemias , Estado Terminal/epidemiologia , Estado Terminal/terapia , SARS-CoV-2 , Enfisema Mediastínico/epidemiologia , Enfisema Mediastínico/terapia , Respiração Artificial , Estudos Retrospectivos
10.
Crit Care ; 26(1): 188, 2022 06 23.
Artigo em Inglês | MEDLINE | ID: mdl-35739553

RESUMO

BACKGROUND: Liberating patients from mechanical ventilation (MV) requires a systematic approach. In the context of a clinical trial, we developed a simple algorithm to identify patients who tolerate assisted ventilation but still require ongoing MV to be randomized. We report on the use of this algorithm to screen potential trial participants for enrollment and subsequent randomization in the Proportional Assist Ventilation for Minimizing the Duration of MV (PROMIZING) study. METHODS: The algorithm included five steps: enrollment criteria, pressure support ventilation (PSV) tolerance trial, weaning criteria, continuous positive airway pressure (CPAP) tolerance trial (0 cmH2O during 2 min) and spontaneous breathing trial (SBT): on fraction of inspired oxygen (FiO2) 40% for 30-120 min. Patients who failed the weaning criteria, CPAP Zero trial, or SBT were randomized. We describe the characteristics of patients who were initially enrolled, but passed all steps in the algorithm and consequently were not randomized. RESULTS: Among the 374 enrolled patients, 93 (25%) patients passed all five steps. At time of enrollment, most patients were on PSV (87%) with a mean (± standard deviation) FiO2 of 34 (± 6) %, PSV of 8.7 (± 2.9) cmH2O, and positive end-expiratory pressure of 6.1 (± 1.6) cmH2O. Minute ventilation was 9.0 (± 3.1) L/min with a respiratory rate of 17.4 (± 4.4) breaths/min. Patients were liberated from MV with a median [interquartile range] delay between initial screening and extubation of 5 [1-49] hours. Only 7 (8%) patients required reintubation. CONCLUSION: The trial algorithm permitted identification of 93 (25%) patients who were ready to extubate, while their clinicians predicted a duration of ventilation higher than 24 h.


Assuntos
Extubação , Desmame do Respirador , Algoritmos , Humanos , Oxigênio , Respiração com Pressão Positiva , Respiração Artificial
11.
JAMA ; 328(12): 1212-1222, 2022 09 27.
Artigo em Inglês | MEDLINE | ID: mdl-36166027

RESUMO

Importance: The benefit of high-flow nasal cannula oxygen (high-flow oxygen) in terms of intubation and mortality in patients with respiratory failure due to COVID-19 is controversial. Objective: To determine whether the use of high-flow oxygen, compared with standard oxygen, could reduce the rate of mortality at day 28 in patients with respiratory failure due to COVID-19 admitted in intensive care units (ICUs). Design, Setting, and Participants: The SOHO-COVID randomized clinical trial was conducted in 34 ICUs in France and included 711 patients with respiratory failure due to COVID-19 and a ratio of partial pressure of arterial oxygen to fraction of inspired oxygen equal to or below 200 mm Hg. It was an ancillary trial of the ongoing original SOHO randomized clinical trial, which was designed to include patients with acute hypoxemic respiratory failure from all causes. Patients were enrolled from January to December 2021; final follow-up occurred on March 5, 2022. Interventions: Patients were randomly assigned to receive high-flow oxygen (n = 357) or standard oxygen delivered through a nonrebreathing mask initially set at a 10-L/min minimum (n = 354). Main Outcomes and Measures: The primary outcome was mortality at day 28. There were 13 secondary outcomes, including the proportion of patients requiring intubation, number of ventilator-free days at day 28, mortality at day 90, mortality and length of stay in the ICU, and adverse events. Results: Among the 782 randomized patients, 711 patients with respiratory failure due to COVID-19 were included in the analysis (mean [SD] age, 61 [12] years; 214 women [30%]). The mortality rate at day 28 was 10% (36/357) with high-flow oxygen and 11% (40/354) with standard oxygen (absolute difference, -1.2% [95% CI, -5.8% to 3.4%]; P = .60). Of 13 prespecified secondary outcomes, 12 showed no significant difference including in length of stay and mortality in the ICU and in mortality up until day 90. The intubation rate was significantly lower with high-flow oxygen than with standard oxygen (45% [160/357] vs 53% [186/354]; absolute difference, -7.7% [95% CI, -14.9% to -0.4%]; P = .04). The number of ventilator-free days at day 28 was not significantly different between groups (median, 28 [IQR, 11-28] vs 23 [IQR, 10-28] days; absolute difference, 0.5 days [95% CI, -7.7 to 9.1]; P = .07). The most common adverse events were ventilator-associated pneumonia, occurring in 58% (93/160) in the high-flow oxygen group and 53% (99/186) in the standard oxygen group. Conclusions and Relevance: Among patients with respiratory failure due to COVID-19, high-flow nasal cannula oxygen, compared with standard oxygen therapy, did not significantly reduce 28-day mortality. Trial Registration: ClinicalTrials.gov Identifier: NCT04468126.


Assuntos
COVID-19 , Oxigenoterapia , Insuficiência Respiratória , COVID-19/complicações , COVID-19/mortalidade , COVID-19/terapia , Cânula/efeitos adversos , Feminino , Humanos , Masculino , Máscaras , Pessoa de Meia-Idade , Oxigênio/administração & dosagem , Oxigenoterapia/efeitos adversos , Insuficiência Respiratória/etiologia , Insuficiência Respiratória/mortalidade , Insuficiência Respiratória/terapia
12.
Crit Care ; 25(1): 391, 2021 Nov 15.
Artigo em Inglês | MEDLINE | ID: mdl-34782003

RESUMO

BACKGROUND: Extubation failure is an important issue in ventilated patients and its risk factors remain a matter of research. We conducted a systematic review and meta-analysis to explore factors associated with extubation failure in ventilated patients who passed a spontaneous breathing trial and underwent planned extubation. This systematic review was registered in PROPERO with the Registration ID CRD42019137003. METHODS: We searched the PubMed, Web of Science and Cochrane Controlled Register of Trials for studies published from January 1998 to December 2018. We included observational studies involving risk factors associated with extubation failure in adult intensive care unit patients who underwent invasive mechanical ventilation. Two authors independently extracted data and assessed the validity of included studies. RESULTS: Sixty-seven studies (involving 26,847 participants) met the inclusion criteria and were included in our meta-analysis. We analyzed 49 variables and, among them, we identified 26 factors significantly associated with extubation failure. Risk factors were distributed into three domains (comorbidities, acute disease severity and characteristics at time of extubation) involving mainly three functions (circulatory, respiratory and neurological). Among these, the physiological respiratory characteristics at time of extubation were the most represented. The individual topic of secretion management was the one with the largest number of variables. By Bayesian multivariable meta-analysis, twelve factors were significantly associated with extubation failure: age, history of cardiac disease, history of respiratory disease, Simplified Acute Physiologic Score II score, pneumonia, duration of mechanical ventilation, heart rate, Rapid Shallow Breathing Index, negative inspiratory force, lower PaO2/FiO2 ratio, lower hemoglobin level and lower Glasgow Coma Scale before extubation, with the latest factor having the strongest association with extubation outcome. CONCLUSIONS: Numerous factors are associated with extubation failure in critically ill patients who have passed a spontaneous breathing trial. Robust multiparametric clinical scores and/or artificial intelligence algorithms should be tested based on the selected independent variables in order to improve the prediction of extubation outcome in the clinical scenario.


Assuntos
Extubação , Estado Terminal , Inteligência Artificial , Teorema de Bayes , Estado Terminal/terapia , Humanos , Falha de Tratamento
13.
Crit Care ; 25(1): 23, 2021 01 09.
Artigo em Inglês | MEDLINE | ID: mdl-33422148

RESUMO

BACKGROUND: Biomarkers of disease severity might help individualizing the management of patients with the acute respiratory distress syndrome (ARDS). Whether the alveolar compartmentalization of biomarkers has a clinical significance in patients with pneumonia-related ARDS is unknown. This study aimed at assessing the interrelation of ARDS/sepsis biomarkers in the alveolar and blood compartments and explored their association with clinical outcomes. METHODS: Immunocompetent patients with pneumonia-related ARDS admitted between 2014 and 2018 were included in a prospective monocentric study. Bronchoalveolar lavage (BAL) fluid and blood samples were obtained within 48 h of admission. Twenty-two biomarkers were quantified in BAL fluid and serum. HLA-DR+ monocytes and CD8+ PD-1+ lymphocytes were quantified using flow cytometry. The primary clinical endpoint of the study was hospital mortality. Patients undergoing a bronchoscopy as part of routine care were included as controls. RESULTS: Seventy ARDS patients were included. Hospital mortality was 21.4%. The BAL fluid-to-serum ratio of IL-8 was 20 times higher in ARDS patients than in controls (p < 0.0001). ARDS patients with shock had lower BAL fluid-to-serum ratio of IL-1Ra (p = 0.026), IL-6 (p = 0.002), IP-10/CXCL10 (p = 0.024) and IL-10 (p = 0.023) than others. The BAL fluid-to-serum ratio of IL-1Ra was more elevated in hospital survivors than decedents (p = 0.006), even after adjusting for SOFA and driving pressure (p = 0.036). There was no significant association between alveolar or alveolar/blood monocytic HLA-DR or CD8+ lymphocytes PD-1 expression and hospital mortality. CONCLUSIONS: IL-8 was the most compartmentalized cytokine and lower BAL fluid-to-serum concentration ratios of IL-1Ra were associated with hospital mortality in patients with pneumonia-associated ARDS.


Assuntos
Biomarcadores/análise , Líquido da Lavagem Broncoalveolar/imunologia , Alvéolos Pulmonares/efeitos dos fármacos , Idoso , Análise de Variância , Biomarcadores/sangue , Lavagem Broncoalveolar/métodos , Estudos de Coortes , Feminino , Citometria de Fluxo/métodos , França , Humanos , Masculino , Pessoa de Meia-Idade , Pneumonia/complicações , Estudos Prospectivos , Síndrome do Desconforto Respiratório , Estatísticas não Paramétricas
14.
Am J Respir Crit Care Med ; 202(11): 1509-1519, 2020 12 01.
Artigo em Inglês | MEDLINE | ID: mdl-32866033

RESUMO

Rationale: Uncontrolled inflammatory innate response and impaired adaptive immune response are associated with clinical severity in patients with coronavirus disease (COVID-19).Objectives: To compare the immunopathology of COVID-19 acute respiratory distress syndrome (ARDS) with that of non-COVID-19 ARDS, and to identify biomarkers associated with mortality in patients with COVID-19 ARDS.Methods: Prospective observational monocenter study. Immunocompetent patients diagnosed with RT-PCR-confirmed severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2) infection and ARDS admitted between March 8 and March 30, 2020, were included and compared with patients with non-COVID-19 ARDS. The primary clinical endpoint of the study was mortality at Day 28. Flow cytometry analyses and serum cytokine measurements were performed at Days 1-2 and 4-6 of ICU admission.Measurements and Main Results: As compared with patients with non-COVID-19 ARDS (n = 36), those with COVID-19 (n = 38) were not significantly different regarding age, sex, and Sequential Organ Failure Assessment and Simplified Acute Physiology Score II scores but exhibited a higher Day-28 mortality (34% vs. 11%, P = 0.030). Patients with COVID-19 showed profound and sustained T CD4+ (P = 0.002), CD8+ (P < 0.0001), and B (P < 0.0001) lymphopenia, higher HLA-DR expression on monocytes (P < 0.001) and higher serum concentrations of EGF (epithelial growth factor), GM-CSF, IL-10, CCL2/MCP-1, CCL3/MIP-1a, CXCL10/IP-10, CCL5/RANTES, and CCL20/MIP-3a. After adjusting on age and Sequential Organ Failure Assessment, serum CXCL10/IP-10 (P = 0.047) and GM-CSF (P = 0.050) were higher and nasopharyngeal RT-PCR cycle threshold values lower (P = 0.010) in patients with COVID-19 who were dead at Day 28.Conclusions: Profound global lymphopenia and a "chemokine signature" were observed in COVID-19 ARDS. Increased serum concentrations of CXCL10/IP-10 and GM-CSF, together with higher nasopharyngeal SARS-CoV-2 viral load, were associated with Day-28 mortality.


Assuntos
Anticorpos Antivirais/sangue , COVID-19/imunologia , COVID-19/fisiopatologia , Quimiocinas/sangue , Imunidade Inata , Síndrome do Desconforto Respiratório/imunologia , Síndrome do Desconforto Respiratório/fisiopatologia , Adulto , Idoso , COVID-19/sangue , COVID-19/epidemiologia , Feminino , França/epidemiologia , Humanos , Masculino , Pessoa de Meia-Idade , Pandemias , Estudos Prospectivos , Síndrome do Desconforto Respiratório/sangue , Síndrome do Desconforto Respiratório/epidemiologia , Carga Viral
15.
BMC Med Educ ; 21(1): 595, 2021 Dec 01.
Artigo em Inglês | MEDLINE | ID: mdl-34852801

RESUMO

BACKGROUND: Understanding respiratory physiology and mechanical ventilation is a challenge for healthcare workers, particularly, medical residents. A team of French-speaking experts developed an innovative MOOC incorporating interactive simulation-based videos and serious games aiming at improving knowledge and skills in mechanical ventilation. Our objective was to evaluate the long-term knowledge retention regarding key concepts presented in this MOOC. METHODS: French residents registered for the MOOC 2020's winter session were invited to participate in a two-step study. The first step consisted in evaluating students' pre-course knowledge of respiratory physiology and mechanical ventilation fusing a 20 five-item multiple choice questions test with a total score ranging from 0 to 100. For the second step, the same students answered the same test (after shuffling the questions) six months after the completion of the course. We assessed the impact of this MOOC on the students' knowledge retention by comparing pre-course and post-course scores. RESULT: Of the 102 residents who agreed to participate in the study, 80 completed the course and their mean ± SD pre-course score was 76.0 ± 8.0. Fifty-one respondents also completed the second and their post-course score was significantly higher than the baseline one (83.1 ± 7.3 vs. 77.5 ± 7.6, p < 0.001). Scores of the first and second rounds did not differ upon comparing respondents' background specialty or number of years of residency. For the vast majority of individual questions (96%), the success rate was higher at the post-course than at the pre-course assessment. CONCLUSION: An innovative MOOC incorporating simulation-based videos was effective in teaching medical residents basic mechanical ventilation knowledge and skills, especially in the field of respiratory physiology and ventilatory modes. We observed effective long-term knowledge retention with a higher score at the post-course assessment six months after the completion of the course compared with the pre-course score.


Assuntos
Educação a Distância , Internato e Residência , Avaliação Educacional , Humanos , Respiração Artificial , Estudantes
16.
Anesthesiology ; 132(6): 1494-1502, 2020 06.
Artigo em Inglês | MEDLINE | ID: mdl-32205549

RESUMO

BACKGROUND: Management of acute respiratory failure by noninvasive ventilation is often associated with asynchronies, like autotriggering or delayed cycling, incurred by leaks from the interface. These events are likely to impair patient's tolerance and to compromise noninvasive ventilation. The development of methods for easy detection and monitoring of asynchronies is therefore necessary. The authors describe two new methods to detect patient-ventilator asynchronies, based on ultrasound analysis of diaphragm excursion or thickening combined with airway pressure. The authors tested these methods in a diagnostic accuracy study. METHODS: Fifteen healthy subjects were placed under noninvasive ventilation and subjected to artificially induced leaks in order to generate the main asynchronies (autotriggering or delayed cycling) at event-appropriate times of the respiratory cycle. Asynchronies were identified and characterized by conjoint assessment of ultrasound records and airway pressure waveforms; both were visualized on the ultrasound screen. The performance and accuracy of diaphragm excursion and thickening to detect each asynchrony were compared with a "control method" of flow/pressure tracings alone, and a "working standard method" combining flow, airway pressure, and diaphragm electromyography signals analyses. RESULTS: Ultrasound recordings were performed for the 15 volunteers, unlike electromyography recordings which could be collected in only 9 of 15 patients (60%). Autotriggering was correctly identified by continuous recording of electromyography, excursion, thickening, and flow/pressure tracings with sensitivity of 93% (95% CI, 89-97%), 94% (95% CI, 91-98%), 91% (95% CI, 87-96%), and 79% (95% CI, 75-84%), respectively. Delayed cycling was detected by electromyography, excursion, thickening, and flow/pressure tracings with sensitivity of 84% (95% CI, 77-90%), 86% (95% CI, 80-93%), 89% (95% CI, 83-94%), and 67% (95% CI, 61-73%), respectively. CONCLUSIONS: Ultrasound is a simple, bedside adjustable, clinical tool to detect the majority of patient-ventilator asynchronies associated with noninvasive ventilation leaks, provided that it is possible to visualize the airway pressure curve on the ultrasound machine screen. Ultrasound detection of autotriggering and delayed cycling is more accurate than isolated observation of pressure and flow tracings, and more feasible than electromyogram.


Assuntos
Diafragma/diagnóstico por imagem , Diafragma/fisiopatologia , Ventilação não Invasiva/métodos , Ultrassonografia/métodos , Adulto , Feminino , Humanos , Masculino , Valores de Referência , Reprodutibilidade dos Testes , Sensibilidade e Especificidade
17.
Crit Care ; 24(1): 678, 2020 12 07.
Artigo em Inglês | MEDLINE | ID: mdl-33287864

RESUMO

RATIONALE: Patients with coronavirus disease-19-related acute respiratory distress syndrome (C-ARDS) could have a specific physiological phenotype as compared with those affected by ARDS from other causes (NC-ARDS). OBJECTIVES: To describe the effect of positive end-expiratory pressure (PEEP) on respiratory mechanics in C-ARDS patients in supine and prone position, and as compared to NC-ARDS. The primary endpoint was the best PEEP defined as the smallest sum of hyperdistension and collapse. METHODS: Seventeen patients with moderate-to-severe C-ARDS were monitored by electrical impedance tomography (EIT) and evaluated during PEEP titration in supine (n = 17) and prone (n = 14) position and compared with 13 NC-ARDS patients investigated by EIT in our department before the COVID-19 pandemic. RESULTS: As compared with NC-ARDS, C-ARDS exhibited a higher median best PEEP (defined using EIT as the smallest sum of hyperdistension and collapse, 12 [9, 12] vs. 9 [6, 9] cmH2O, p < 0.01), more collapse at low PEEP, and less hyperdistension at high PEEP. The median value of the best PEEP was similar in C-ARDS in supine and prone position: 12 [9, 12] vs. 12 [10, 15] cmH2O, p = 0.59. The response to PEEP was also similar in C-ARDS patients with higher vs. lower respiratory system compliance. CONCLUSION: An intermediate PEEP level seems appropriate in half of our C-ARDS patients. There is no solid evidence that compliance at low PEEP could predict the response to PEEP.


Assuntos
COVID-19/fisiopatologia , Respiração com Pressão Positiva/métodos , Síndrome do Desconforto Respiratório/diagnóstico por imagem , Tomografia Computadorizada por Raios X/métodos , Tomografia Computadorizada por Raios X/normas , Adulto , COVID-19/diagnóstico por imagem , Impedância Elétrica/uso terapêutico , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Respiração com Pressão Positiva/instrumentação , Síndrome do Desconforto Respiratório/fisiopatologia , Mecânica Respiratória/fisiologia , Tomografia Computadorizada por Raios X/instrumentação
18.
Crit Care ; 24(1): 679, 2020 12 07.
Artigo em Inglês | MEDLINE | ID: mdl-33287866

RESUMO

BACKGROUND: Microaspiration of gastric and oropharyngeal secretions is the main causative mechanism of ventilator-associated pneumonia (VAP). Transesophageal echocardiography (TEE) is a routine investigation tool in intensive care unit and could enhance microaspiration. This study aimed at evaluating the impact of TEE on microaspiration and VAP in intubated critically ill adult patients. METHODS: It is a four-center prospective observational study. Microaspiration biomarkers (pepsin and salivary amylase) concentrations were quantitatively measured on tracheal aspirates drawn before and after TEE. The primary endpoint was the percentage of patients with TEE-associated microaspiration, defined as: (1) ≥ 50% increase in biomarker concentration between pre-TEE and post-TEE samples, and (2) a significant post-TEE biomarker concentration (> 200 µg/L for pepsin and/or > 1685 IU/L for salivary amylase). Secondary endpoints included the development of VAP within three days after TEE and the evolution of tracheal cuff pressure throughout TEE. RESULTS: We enrolled 100 patients (35 females), with a median age of 64 (53-72) years. Of the 74 patients analyzed for biomarkers, 17 (23%) got TEE-associated microaspiration. However, overall, pepsin and salivary amylase levels were not significantly different between before and after TEE, with wide interindividual variability. VAP occurred in 19 patients (19%) within 3 days following TEE. VAP patients had a larger tracheal tube size and endured more attempts of TEE probe introduction than their counterparts but showed similar aspiration biomarker concentrations. TEE induced an increase in tracheal cuff pressure, especially during insertion and removal of the probe. CONCLUSIONS: We could not find any association between TEE-associated microaspiration and the development of VAP during the three days following TEE in intubated critically ill patients. However, our study cannot formally rule out a role for TEE because of the high rate of VAP observed after TEE and the limitations of our methods.


Assuntos
Ecocardiografia Transesofagiana/efeitos adversos , Pneumonia Associada à Ventilação Mecânica/etiologia , Aspiração Respiratória/etiologia , Traqueia/lesões , Idoso , Estado Terminal/terapia , Ecocardiografia Transesofagiana/métodos , Feminino , França , Humanos , Intubação Intratraqueal/métodos , Masculino , Pessoa de Meia-Idade , Estudos Prospectivos , Aspiração Respiratória/diagnóstico por imagem , Aspiração Respiratória/fisiopatologia , Traqueia/diagnóstico por imagem
19.
Crit Care ; 24(1): 699, 2020 12 18.
Artigo em Inglês | MEDLINE | ID: mdl-33339526

RESUMO

BACKGROUND: Data on incidence of ventilator-associated pneumonia (VAP) and invasive pulmonary aspergillosis in patients with severe SARS-CoV-2 infection are limited. METHODS: We conducted a monocenter retrospective study comparing the incidence of VAP and invasive aspergillosis between patients with COVID-19-related acute respiratory distress syndrome (C-ARDS) and those with non-SARS-CoV-2 viral ARDS (NC-ARDS). RESULTS: We assessed 90 C-ARDS and 82 NC-ARDS patients, who were mechanically ventilated for more than 48 h. At ICU admission, there were significantly fewer bacterial coinfections documented in C-ARDS than in NC-ARDS: 14 (16%) vs 38 (48%), p < 0.01. Conversely, significantly more patients developed at least one VAP episode in C-ARDS as compared with NC-ARDS: 58 (64%) vs. 36 (44%), p = 0.007. The probability of VAP was significantly higher in C-ARDS after adjusting on death and ventilator weaning [sub-hazard ratio = 1.72 (1.14-2.52), p < 0.01]. The incidence of multi-drug-resistant bacteria (MDR)-related VAP was significantly higher in C-ARDS than in NC-ARDS: 21 (23%) vs. 9 (11%), p = 0.03. Carbapenem was more used in C-ARDS than in NC-ARDS: 48 (53%), vs 21 (26%), p < 0.01. According to AspICU algorithm, there were fewer cases of putative aspergillosis in C-ARDS than in NC-ARDS [2 (2%) vs. 12 (15%), p = 0.003], but there was no difference in Aspergillus colonization. CONCLUSIONS: In our experience, we evidenced a higher incidence of VAP and MDR-VAP in C-ARDS than in NC-ARDS and a lower risk for invasive aspergillosis in the former group.


Assuntos
COVID-19/microbiologia , Unidades de Terapia Intensiva , Pneumonia Associada à Ventilação Mecânica/microbiologia , Respiração Artificial/efeitos adversos , Síndrome do Desconforto Respiratório/microbiologia , Adulto , Estudos de Casos e Controles , Feminino , Humanos , Aspergilose Pulmonar Invasiva/diagnóstico , Masculino , Pessoa de Meia-Idade , Estudos Retrospectivos , Fatores de Risco
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA