Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 17 de 17
Filtrar
1.
BMC Oral Health ; 24(1): 1158, 2024 Sep 29.
Artigo em Inglês | MEDLINE | ID: mdl-39343921

RESUMO

This paper aims to reply to Somay et al., regarding their comment to a previous paper from our group, titled "Clinical outcomes of teeth adjacent to the site of mandibulotomy or mandibulectomy in patients with head and neck cancer: results from a multidisciplinary mono-institutional head and neck tumor board".The following concerns were addressed: 1) Within the limits of a case series, mandibulectomy might be considered a risk factor for the loss of tooth vitality as well as mandibulotomy. 2) Root canal therapy before surgery on the teeth adjacent to the surgical site could be an appropriate strategy, although in some cased it may involve teeth which are not destinate to have endodontic complications. 3) Dose-volume data of the included teeth were provided: the impact of radiotherapy (RT) as a confounding factor seems not to be as relevant as Somay et al. have pointed out.


Assuntos
Neoplasias de Cabeça e Pescoço , Osteotomia Mandibular , Humanos , Neoplasias de Cabeça e Pescoço/cirurgia , Neoplasias de Cabeça e Pescoço/radioterapia , Osteotomia Mandibular/métodos , Mandíbula/cirurgia
2.
BMC Oral Health ; 23(1): 357, 2023 06 03.
Artigo em Inglês | MEDLINE | ID: mdl-37270480

RESUMO

INTRODUCTION: The aim of this case series was to evaluate the necrosis of teeth adjacent to the site of mandibulotomy or mandibulectomy in a cohort of patients suffering from head and neck cancers. METHODS: Fourteen patients who underwent segmental mandibulectomy or paramedian mandibulotomy for oral, oropharynx or major salivary gland cancer and a total of 23 teeth were included in this case series. Twelve patients underwent adjuvant head and neck radiotherapy. Cold sensitivity pulp testing and/or electric pulp testing were performed on teeth at the margin of mandibulectomy and on teeth adjacent to mandibulotomy after surgery. A "positive" response was considered the healthy state, and "negative" was considered the diseased state of the tooth. RESULTS: The 10 patients who underwent mandibulotomy had 12 teeth with a negative response. The 4 patients treated by mandibulectomy had two positive and three negative responses to cold and electric pulp tests. Fifteen out of 23 teeth (65.2%) showed a negative response to sensitivity testing. CONCLUSIONS: Tooth necrosis seems to be a common event after mandibulectomy and mandibulotomy. CLINICAL RELEVANCE: To avoid post-surgery complications, performing root canal therapy before surgery on the teeth adjacent to the surgical site could be an appropriate strategy.


Assuntos
Neoplasias de Cabeça e Pescoço , Neoplasias Bucais , Humanos , Osteotomia Mandibular , Neoplasias Bucais/cirurgia , Neoplasias de Cabeça e Pescoço/cirurgia , Complicações Pós-Operatórias , Necrose
3.
Clin Oral Investig ; 20(7): 1547-50, 2016 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-26531192

RESUMO

OBJECTIVE: The aim of this study on human cadavers was to compare the accuracy of two electronic apex locators (EALs) Dentaport ZX (J. Morita Corporation, Tokyo, Japan) and Raypex 6 (VDW, Munich, Germany). MATERIALS AND METHODS: Twenty-two single rooted teeth of four human cadaver heads were scheduled for this study. Before the extraction, an access cavity was opened and the crown was cut to establish a stable reference point for all measurements. The working length determination was performed with Dentaport ZX and Raypex 6 in the presence or not of 5.25 % sodium hypochlorite (SH) using a k-file 10. The teeth were then extracted and the real working length (RWL) was measured under a stereomicroscope at ×30 magnification. The difference between the two working lengths was calculated: positive values indicate measurements exceeding the foramen, while negative values indicated measurements short of the foramen. The data were analyzed with a t test analysis. RESULTS: The mean of distances was 0.33 ± 0.20 mm and 0.32 ± 0.2 mm for Dentaport ZX respectively in the presence or not of SH and 0.38 ± 0.20 mm and 0.39 ± 0.19 mm for Raypex 6. No statistical differences were found between the two devices (p > 0.05). CONCLUSIONS: Both apex locators showed a high accuracy in the presence or not of SH. CLINICAL RELEVANCE: Both electronic apex locators can be recommended for clinical use and their accuracy is not affected by SH.


Assuntos
Odontometria/instrumentação , Tratamento do Canal Radicular/instrumentação , Ápice Dentário/anatomia & histologia , Cadáver , Humanos , Irrigantes do Canal Radicular/química , Hipoclorito de Sódio/química , Propriedades de Superfície
4.
Eur Endod J ; 9(1): 81-88, 2024 01 01.
Artigo em Inglês | MEDLINE | ID: mdl-37965676

RESUMO

OBJECTIVE: The aim of this in vitro study was to compare the smear layer and debris removal and antimicrobial activity of two dual-action irrigating solutions for continuous chelation (Triton; Brasseler, Savannah, USA and Dual Rinse HEDP; Medcem GmbH, Weinfelden, Switzerland) with a dual step irrigation protocol with sodium hypochlorite (NaOCl) followed by ethylenediaminetetraacetic acid (EDTA). METHODS: Thirty single-rooted single-canal teeth were divided into three groups (n=10) and irrigated with Triton, Dual Rinse HEDP mixed with 6% NaOCl and 6% NaOCl/17% EDTA. The teeth were observed under a scanning electron microscope (SEM) to assess the canal wall cleanliness. In addition, 80 dentine discs were contaminated with Candida albicans and 80 discs with Enterococcus faecalis and irrigated with Triton, Dual Rinse HEDP mixed with 6% NaOCl and 6% NaOCl/17% EDTA or not treated (n=20). Fifteen discs were used to evaluate colony-forming units, while 5 discs were analysed by SEM. Data were analysed using the Shapiro- Wilk, Kruskal-Wallis and One-Way ANOVA tests. RESULTS: Triton was statistically more effective than Dual Rinse HEDP and NaOCl/EDTA in removing debris (p<0.05), except with NaOCl/EDTA in the coronal third. Triton was more effective than Dual Rinse HEDP in removing the smear layer from the apical and middle thirds (p<0.05). All the irrigation protocols significantly re- duced the number of E. faecalis. The Triton group showed the lowest number of remaining C. albicans (p<0.05). CONCLUSION: Triton was the most effective irrigation solution in removing debris and as effective as NaOCl/ EDTA in removing the smear layer. Triton showed the highest efficacy against C. albicans. New irrigating solutions that provide continuous chelation may provide an alternative to current irrigation protocols.


Assuntos
Anti-Infecciosos , Camada de Esfregaço , Humanos , Ácido Edético/farmacologia , Ácido Etidrônico , Microscopia Eletrônica de Varredura , Cavidade Pulpar , Preparo de Canal Radicular/métodos , Irrigantes do Canal Radicular/farmacologia , Quelantes/farmacologia , Anti-Infecciosos/farmacologia
5.
Nutrients ; 16(3)2024 Jan 26.
Artigo em Inglês | MEDLINE | ID: mdl-38337645

RESUMO

This systematic review and meta-analyses aimed to assess whether malnutrition may increase the incidence of oral cancer. Following the PRISMA statement, the research was conducted on PubMed, Scopus, and MEDLINE via OVID without any time restrictions. The risk of bias was assessed, and the quality of evidence for each performed meta-analysis was evaluated using the Grading of Recommendations Assessment, Development and Evaluation (GRADE) framework. Sixty-one articles met the inclusion criteria and seven studies underwent quantitative evaluation. For our meta-analysis on hypovitaminosis B, three studies with a total of 90,011 patients were included. An odds ratio of 2.22 was found. Our meta-analysis on the correlation between vitamin C and oral cancer included one study with a total of 866 patients and the derived odds ratio was 1.06. Our meta-analysis on the relationship between vitamin D deficiency and the incidence of oral cancer included three studies with a total of 12,087 patients and the odds ratio was -2.58. The GRADE system showed a moderate strength of evidence due to the presence of studies with a high risk of bias and high indirectness of the data given. The present findings suggest that an inadequate intake of vitamins, particularly vitamin D, poses a risk for the onset of oral cancer.


Assuntos
Desnutrição , Neoplasias Bucais , Deficiência de Vitamina D , Humanos , Neoplasias Bucais/epidemiologia , Neoplasias Bucais/etiologia , Fatores de Risco , Desnutrição/epidemiologia , Desnutrição/complicações , Deficiência de Vitamina D/complicações , Deficiência de Vitamina D/epidemiologia , Incidência , Razão de Chances , Feminino , Masculino , Vitamina D/sangue , Vitamina D/administração & dosagem
6.
Pharmaceutics ; 15(5)2023 May 22.
Artigo em Inglês | MEDLINE | ID: mdl-37242801

RESUMO

Due to its numerous advantages, such as excellent drug accessibility, rapid absorption, and bypass of first-pass metabolism, the route of drug administration that involves crossing the oral mucosa is highly favored. As a result, there is significant interest in investigating the permeability of drugs through this region. The purpose of this review is to describe the various ex vivo and in vitro models used to study the permeability of conveyed and non-conveyed drugs through the oral mucosa, with a focus on the most effective models. Currently, there is a growing need for standardized models of this mucosa that can be used for developing new drug delivery systems. Oral Mucosa Equivalents (OMEs) may provide a promising future perspective as they are capable of overcoming limitations present in many existing models.

7.
Biomed Res Int ; 2022: 5100816, 2022.
Artigo em Inglês | MEDLINE | ID: mdl-36440368

RESUMO

The aim of this study was to analyse the cytocompatibility of Surefil One (SuO) with respect to the release of monomers from the material. The following reference materials were chosen: SDR Flow Plus (SDR, Dentsply Sirona, Konstanz, Germany), One Q Bond (Q, Dentalica, Milan, Italy), and Ketac (K, 3M-ESPE, USA). Fifteen dentin discs (2 mm thickness and diameter) were obtained from 15 third molars and were used in this study. After dentin disc permeability measurement, murine fibroblasts were grown, and the pulp surface of the dentinal disc was placed in direct contact with the cells immersed in DMEM. The experimental materials were positioned on the occlusal side of each dentinal disc until a uniform thickness of 2 mm was obtained. Then, the discs were inserted into an artificial pulp chamber for 24 hours to assess the cytocompatibility. Afterwards, the moles of monomers leached from the specimens in DMEM were determined using HPLC. Statistical analysis was performed using ANOVA (p < 0.05). Under the experimental conditions, the toxic effect induced by all tested materials was slight or absent. Diurethane dimethacrylate and acrylic acid were not found in the culture media. It is concluded that all materials have good cytocompatibility consistent with the nondeterminability of the monomers released after polymerization.


Assuntos
Resinas Compostas , Cavidade Pulpar , Camundongos , Animais , Resinas Compostas/química , Dentina , Alemanha , Itália
8.
Restor Dent Endod ; 47(1): e3, 2022 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-36578274

RESUMO

Objectives: This study aimed to assess the impact of a glide-path on the shaping ability of 2 single-file instruments and to compare the centering ability, maintenance of original canal curvatures and area of instrumentation in simulated S-shaped root canals. Materials and Methods: Forty simulated S-shaped root canals were used and were prepared with One Curve (group OC), One G and OC (group GOC), Reciproc Blue (group RB) and R-Pilot and RB (group PRB) and scanned before and after instrumentation. The images were analyzed using AutoCAD. After superimposing the samples, 4 levels (D1, D2, D3, and D4) and 2 angles (Δ1 and Δ2) were established to evaluate the centering ability and modification of the canal curvatures. Then, the area of instrumentation (ΔA) was measured. The data were analyzed using 2-way analysis of variance and Tukey's test for multiple comparisons (p < 0.05). Results: Regarding the centering ability in the apical part (D3, D4), the use of the glide-path yielded better results than the single-file groups. Among the groups at D4, OC showed the worst results (p < 0.05). The OC system removed less material (ΔA) than the RB system, and for Δ1, OC yielded a worse result than RB (p < 0.05). Conclusions: The glide-path improved the centering ability in the apical part of the simulated S-shaped canals. The RB system showed a better centering ability in the apical part and major respect of the canal curvatures compared with OC system.

9.
Am J Dent ; 24(1): 25-30, 2011 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-21469403

RESUMO

PURPOSE: To evaluate the bond strength of resin dentin interfaces created with adhesives applied on root dentin using the water wet or ethanol wet bonding technique. The morphology of resin dentin interfaces was evaluated using confocal microscopy. METHODS: Four experimental resin adhesives (R#A to R#D) and one commercial three-step/etch and rinse adhesive were applied to the root canal dentin of endodontically treated single canal incisors using the water (control) or ethanol wet bonding technique. The ethanol wet bonding substrate was achieved by keeping the root canal immersed in absolute ethanol (100%) for 3 minutes. The root dentin bonded specimens were sectioned into beams, stored in distilled water (24 hours) and finally tested for microtensile bond strengths (tTBS). Additional dentin surfaces were conditioned and bonded as previously described. They were prepared for the microscopy study and finally observed using confocal microscopy. RESULTS: The ethanol wet bonding technique gave higher bond strength values for all the adhesives tested: in Group 1 (water wet bonding technique) no significant difference was found between the resins tested; the only exception being the most hydrophilic Resin #4 showing the highest bond strength values (P < 0.05). In Group 2 (ethanol wet bonding technique) no statistical differences were present between Resin #A and Resin #D. Resin #C showed the highest bond strength values. Confocal microscopy showed better resin diffusion and hybrid layer formation when the ethanol wet bonding was used.


Assuntos
Resinas Compostas , Colagem Dentária/métodos , Cavidade Pulpar , Dentina , Cimentos de Resina/química , Análise de Variância , Análise do Estresse Dentário , Permeabilidade da Dentina , Etanol , Humanos , Interações Hidrofóbicas e Hidrofílicas , Incisivo , Teste de Materiais , Microscopia Confocal , Resistência à Tração , Água
10.
Minerva Dent Oral Sci ; 70(5): 214-222, 2021 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-33988331

RESUMO

Dental caries is one of the most common diseases in the world, and global incidence rates are increasing. The early detection of dental lesions enables a conservative approach to be employed and represents a priority in modern dentistry. Recent studies have suggested that conventional diagnostic methods, such as visual tactile inspection and X-ray examination, exhibit low sensitivity and are not very effective in early diagnoses. Consequently, late detection of decay is associated with an increased loss of tooth structure. New diagnostic systems based on optical properties have been developed to facilitate early detection. Several studies have evaluated the performance of near-infrared imaging (NIRI) as an early diagnostic tool. NIRI using light ranging from 700 to 1700 nm has demonstrated better optical properties compared to conventional optical systems using light in the visible spectra. NIRI enables deeper penetration of the light in the tooth tissue, weak scattering with lower background noise and strong photon absorption with detailed images. Several in-vivo studies have demonstrated that NIRI technology has the potential to improve performance compared with current diagnostic methods. NIRI exhibits increased sensitivity compared to radiographs and is more suitable to identify approximal enamel lesions. This paper aimed to review these recent advances and their potential applications in daily clinical practice.


Assuntos
Cárie Dentária , Dente , Cárie Dentária/diagnóstico , Esmalte Dentário/diagnóstico por imagem , Humanos , Exame Físico , Raios X
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA