Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 3 de 3
Filtrar
Mais filtros

Base de dados
Tipo de documento
País de afiliação
Intervalo de ano de publicação
1.
Europace ; 2024 Sep 10.
Artigo em Inglês | MEDLINE | ID: mdl-39255332

RESUMO

BACKGROUND AND AIMS: Both isolated thoracoscopic and hybrid thoracoscopic atrial fibrillation (AF) ablation techniques have demonstrated favorable outcomes in the management of patients with (long-standing) persistent AF, as compared to catheter ablation. However, it is currently unknown whether there is a difference in short- and long-term outcomes when comparing these two minimally invasive surgical AF ablation procedures. Therefore, a systematic review and meta-analysis were performed to investigate these two techniques, with a specific emphasis on long-term freedom from atrial tachyarrhythmias (ATA). METHODS: A systematic search through PubMed, EMBASE, and the Cochrane Library databases was performed. All studies reporting on short-term outcomes were included in the meta-analysis. A pooled analysis of long-term freedom from ATA was performed based on Kaplan-Meier (KM) curve-derived individual patient data (IPD). Reconstructed individual time-to-event data were analyzed in a multivariable Cox frailty model with adjustments for age, sex, type of AF, duration of AF history, and study variable (frailty term in the frailty Cox model). RESULTS: In total, 53 studies were included in the meta-analysis, encompassing 4950 patients. There were no differences in major short-term outcomes (mortality or stroke) between isolated thoracoscopic and hybrid thoracoscopic ablation. A total of 18 studies reported KM curves for long-term freedom from ATA, comprising 2038 patients. Adjusted analysis revealed that hybrid ablation was significantly associated with greater freedom from ATA (Adjusted Hazard Ratio [aHR]=0.59, 95%CI: 0.43-0.83, p<0.001) compared to isolated thoracoscopic ablation. Additionally, older age (aHR=1.07, 95%CI: 1.03-1.12, p=0.002) and a higher percentage of male patients (aHR=1.02, 95% CI: 1.01-1.03, p<0.001) were significantly associated with lower long-term freedom from ATA recurrence. CONCLUSION: Hybrid thoracoscopic AF-ablation is associated with a greater long-term freedom from ATA when compared to isolated thoracoscopic ablation, without differences in complications.

2.
Am Heart J ; 250: 45-56, 2022 08.
Artigo em Inglês | MEDLINE | ID: mdl-35537503

RESUMO

BACKGROUND: Left atrial appendage occlusion (LAAO) provides an alternative to oral anticoagulation (OAC) for stroke prevention in patients with atrial fibrillation (AF). In patients with a long-term or permanent contraindication for OAC randomized controlled trial (RCT) data is lacking. STUDY OBJECTIVES: To assess the efficacy and safety of LAAO in AF patients who are ineligible to use OAC. The co-primary efficacy endpoint is (1) time to first occurrence of stroke (ischemic, hemorrhagic, or undetermined) and (2) time to first occurrence of the composite of stroke, transient ischemic attack (TIA), and systemic embolism (SE). The primary safety endpoint is the 30-day rate of peri-procedural complications. STUDY DESIGN: This is a multicenter, investigator-initiated, open-label, blinded endpoint (PROBE), superiority-driven RCT. Patients with AF, a CHA2DS2-VASc score ≥2 for men and ≥3 for women and a long-term or permanent contraindication for OAC will be randomized in a 2:1 fashion to the device- or control arm. Patients in the device arm will undergo percutaneous LAAO and will receive post-procedural dual antiplatelet therapy (DAPT) per protocol, while those in the control arm will continue their current treatment consisting of no antithrombotic therapy or (D)APT as deemed appropriate by the primary responsible physician. In this endpoint-driven trial design, assuming a 50% lower stroke risk of LAAO compared to conservative treatment, 609 patients will be followed for a minimum of 1 and a maximum of 5 years. Cost-effectiveness and budget impact analyses will be performed to allow decision-making on reimbursement of LAAO for the target population in the Netherlands. SUMMARY: The COMPARE LAAO trial will investigate the clinical superiority in preventing thromboembolic events and cost-effectiveness of LAAO in AF patients with a high thromboembolic risk and a contraindication for OAC use. NCT TRIAL NUMBER: NCT04676880.


Assuntos
Apêndice Atrial , Fibrilação Atrial , Acidente Vascular Cerebral , Tromboembolia , Anticoagulantes , Apêndice Atrial/cirurgia , Fibrilação Atrial/complicações , Fibrilação Atrial/tratamento farmacológico , Feminino , Humanos , Masculino , Padrão de Cuidado , Acidente Vascular Cerebral/complicações , Acidente Vascular Cerebral/prevenção & controle , Tromboembolia/etiologia , Tromboembolia/prevenção & controle , Resultado do Tratamento
3.
Eur Heart J Digit Health ; 2(3): 363-373, 2021 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-36713592

RESUMO

Aims: Within the TeleCheck-AF project, numerous centres in Europe used on-demand photoplethysmography (PPG) technology to remotely assess heart rate and rhythm in conjunction with teleconsultations. Based on the TeleCheck-AF investigator experiences, we aimed to develop an educational structured stepwise practical guide on how to interpret PPG signals and to introduce typical clinical scenarios how on-demand PPG was used. Methods and results: During an online conference, the structured stepwise practical guide on how to interpret PPG signals was discussed and further refined during an internal review process. We provide the number of respective PPG recordings (FibriCheck®) and number of patients managed within a clinical scenario during the TeleCheck-AF project. To interpret PPG recordings, we introduce a structured stepwise practical guide and provide representative PPG recordings. In the TeleCheck-AF project, 2522 subjects collected 90 616 recordings in total. The majority of these recordings were classified by the PPG algorithm as sinus rhythm (57.6%), followed by AF (23.6%). In 9.7% of recordings, the quality was too low to interpret. The most frequent clinical scenarios where PPG technology was used in the TeleCheck-AF project was a follow-up after AF ablation (1110 patients) followed by heart rate and rhythm assessment around (tele)consultation (966 patients). Conclusion: We introduce a newly developed structured stepwise practical guide on PPG signal interpretation developed based on presented experiences from TeleCheck-AF. The present clinical scenarios for the use of on-demand PPG technology derived from the TeleCheck-AF project will help to implement PPG technology in the management of AF patients.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA