Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 53
Filtrar
Mais filtros

Base de dados
País/Região como assunto
Tipo de documento
Intervalo de ano de publicação
1.
Eur Radiol ; 30(1): 581-587, 2020 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-31410602

RESUMO

OBJECTIVES: As the relationship between CT scout landmarks and chest CT boundaries is not known, the selected scan length is often greater than necessary for the CT scan, resulting in increased radiation dose to the neck and upper abdomen. The purpose of this study is to establish the relationship between CT scout landmarks with the superior and inferior boundaries of the lungs on chest CT. METHODS: Retrospective comparison of the location of the top of the first rib on frontal scout and the most inferior costophrenic angle on lateral scout to the chest CT slice just above and below the lungs. The percent of scans that would exclude part of the lung based on CT initiated at several distances above or below these landmarks was calculated. RESULTS: There was 2.7 times greater variability between scout landmarks and lung boundaries inferiorly than superiorly on chest CT (p < 0.001). Initiating CT at the top of the first rib on scout did not exclude any lung on CT. Initiating CT 0, 1, 2, 3, and 4 cm inferior to the CPA on lateral scout excluded part of the lung in 45.7%, 12.9%, 4.3%, 1.9%, and 0.8% of CTs. CONCLUSIONS: Chest CT to include the lungs should be performed from the top of the first rib to 3 or 4 cm below the costophrenic angle on lateral topogram. KEY POINTS: • There is a greater motion at the inferior lung than at the superior lung. • Chest CT acquisition from the top of the first rib on scout would not exclude the lung. • Chest CT acquisition from CPA on lateral scout would exclude the lung 46% of time.


Assuntos
Pulmão/diagnóstico por imagem , Doses de Radiação , Radiografia Torácica/métodos , Tomografia Computadorizada por Raios X/métodos , Abdome , Idoso , Algoritmos , Estudos de Coortes , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Pescoço , Estudos Retrospectivos
2.
J Card Fail ; 24(2): 78-86, 2018 02.
Artigo em Inglês | MEDLINE | ID: mdl-28801077

RESUMO

BACKGROUND: Cardiac magnetic resonance (CMR) has demonstrated its utility in the noninvasive diagnosis of cardiac amyloidosis (CA). Our aim was to evaluate the ability of standard Look-Locker sequences to quantify amyloid deposition in CA. METHODS AND RESULTS: Consecutive patients referred for CMR for possible CA were retrospectively evaluated. Positive cardiac biopsy and/or typical pattern of late gadolinium enhancement were required for the diagnosis of CA. Postcontrast T1 values were obtained from Look-Locker sequences and correlated with markers of severity of disease and major events. When cardiac biopsies were available, histological validation was determined. A total of 174 patients were included. A final diagnosis of CA was reached in 37.4%. Myocardial and endocardial T1 times, as well as the respective ratios with blood and skeletal muscle, were lower among patients with CA and demonstrated good diagnostic performance. The best parameters were myocardial/blood (area under the curve 0.83; P < .001) and endocardial/blood (area under the curve 0.84; P < .001) T1 ratios. Among patients with CA, no associations were found between T1 ratios either with markers of amyloid burden or with prognostic variables. However, all T1 indexes showed significant correlations with histological quantification of amyloid deposition. CONCLUSIONS: Look-Looker derived postcontrast T1 shows good diagnostic accuracy to detect CA and correlation with histological amyloid burden.


Assuntos
Amiloide/metabolismo , Amiloidose/diagnóstico , Cardiomiopatias/diagnóstico , Imagem Cinética por Ressonância Magnética/métodos , Miocárdio/metabolismo , Idoso , Amiloidose/metabolismo , Biópsia , Cardiomiopatias/metabolismo , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Miocárdio/patologia , Reprodutibilidade dos Testes , Estudos Retrospectivos
3.
Eur Radiol ; 28(3): 1085-1094, 2018 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-28983713

RESUMO

OBJECTIVES: Differences in results of baseline and subsequent annual repeat rounds provide important information for optimising the regimen of screening. METHODS: A prospective cohort study of 65,374 was reviewed to examine the frequency/percentages of the largest noncalcified nodule (NCN), lung cancer cell types and Kaplan-Meier (K-M) survival rates, separately for baseline and annual rounds. RESULTS: Of 65,374 baseline screenings, NCNs were identified in 28,279 (43.3%); lung cancer in 737 (1.1%). Of 74,482 annual repeat screenings, new NCNs were identified in 4959 (7%); lung cancer in 179 (0.24%). Only adenocarcinoma was diagnosed in subsolid NCNs. Percentages of lung cancers by cell type were significantly different (p < 0.0001) in the baseline round compared with annual rounds, reflecting length bias, as were the ratios, reflecting lead times. Long-term K-M survival rate was 100% for typical carcinoids and for adenocarcinomas manifesting as subsolid NCNs; 85% (95% CI 81-89%) for adenocarcinoma, 74% (95% CI 63-85%) for squamous cell, 48% (95% CI 34-62%) for small cell. The rank ordering by lead time was the same as the rank ordering by survival rates. CONCLUSIONS: The significant differences in the frequency of NCNs and frequency and aggressiveness of diagnosed cancers in baseline and annual repeat need to be recognised for an optimal regimen of screening. KEY POINTS: • Lung cancer aggressiveness varies considerably by cell type and nodule consistency. • Kaplan-Meier survival rates varied by cell type between 100% and 48%. • The percentages of lung cancers by cell type in screening rounds reflect screening biases. • Rank ordering by cell type survival is consistent with that by lead times. • Empirical evidence provides critical information for the regimen of screening.


Assuntos
Detecção Precoce de Câncer/métodos , Neoplasias Pulmonares/diagnóstico por imagem , Adenocarcinoma/diagnóstico por imagem , Adenocarcinoma/mortalidade , Idoso , Bases de Dados Factuais , Feminino , Humanos , Estimativa de Kaplan-Meier , Neoplasias Pulmonares/mortalidade , Masculino , Programas de Rastreamento/métodos , Programas de Rastreamento/organização & administração , Pessoa de Meia-Idade , Estudos Prospectivos , Nódulo Pulmonar Solitário/diagnóstico por imagem , Nódulo Pulmonar Solitário/mortalidade , Tomografia Computadorizada por Raios X/métodos
4.
Eur Radiol ; 28(7): 3114, 2018 07.
Artigo em Inglês | MEDLINE | ID: mdl-29442132

RESUMO

The original version of this article unfortunately contained a mistake. The conflict of interest was incorrect.

5.
J Cardiovasc Magn Reson ; 15: 42, 2013 May 24.
Artigo em Inglês | MEDLINE | ID: mdl-23706156

RESUMO

BACKGROUND: Dynamic contrast enhanced (DCE) cardiovascular magnetic resonance (CMR) is increasingly used to quantify microvessels and permeability in atherosclerosis. Accurate quantification depends on reliable sampling of both vessel wall (VW) uptake and contrast agent dynamic in the blood plasma (the so called arterial input function, AIF). This poses specific challenges in terms of spatial/temporal resolution and matched dynamic MR signal range, which are suboptimal in current vascular DCE-CMR protocols. In this study we describe a novel dual-imaging approach, which allows acquiring simultaneously AIF and VW images using different spatial/temporal resolution and optimizes imaging parameters for the two compartments. We refer to this new acquisition as SHILO, Simultaneous HI-/LOw-temporal (low-/hi-spatial) resolution DCE-imaging. METHODS: In SHILO, the acquisition of low spatial resolution single-shot AIF images is interleaved with segments of higher spatial resolution images of the VW. This allows sampling the AIF and VW with different spatial/temporal resolution and acquisition parameters, at independent spatial locations. We show the adequacy of this temporal sampling scheme by using numerical simulations. Following, we validate the MR signal of SHILO against a standard 2D spoiled gradient recalled echo (SPGR) acquisition with in vitro and in vivo experiments. Finally, we show feasibility of using SHILO imaging in subjects with carotid atherosclerosis. RESULTS: Our simulations confirmed the superiority of the SHILO temporal sampling scheme over conventional strategies that sample AIF and tissue curves at the same time resolution. Both the median relative errors and standard deviation of absolute parameter values were lower for the SHILO than for conventional sampling schemes. We showed equivalency of the SHILO signal and conventional 2D SPGR imaging, using both in vitro phantom experiments (R2 =0.99) and in vivo acquisitions (R2 =0.95). Finally, we showed feasibility of using the newly developed SHILO sequence to acquire DCE-CMR data in subjects with carotid atherosclerosis to calculate plaque perfusion indices. CONCLUSIONS: We successfully demonstrate the feasibility of using the newly developed SHILO dual-imaging technique for simultaneous AIF and VW imaging in DCE-CMR of atherosclerosis. Our initial results are promising and warrant further investigation of this technique in wider studies measuring kinetic parameters of plaque neovascularization with validation against gold standard techniques.


Assuntos
Doenças das Artérias Carótidas/diagnóstico , Angiografia por Ressonância Magnética/métodos , Neovascularização Patológica/diagnóstico , Doenças das Artérias Carótidas/patologia , Meios de Contraste , Estudos de Viabilidade , Gadolínio DTPA , Humanos , Análise dos Mínimos Quadrados , Neovascularização Patológica/patologia , Imagens de Fantasmas , Fatores de Tempo
6.
Emerg Radiol ; 19(3): 211-5, 2012 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-22370693

RESUMO

The purpose of this study is to determine how often CT is repeated to obtain chest/abdomen/pelvis data outside the reconstructed field of view (FOV) on a prior spine CT. Radiology records of 1,239 consecutive thoracic and lumbar spine CT exams of 1,025 patients from January 1, 2006 to December 31, 2008 were retrospectively reviewed to identify patients who subsequently had CT studies of the chest, abdomen, and/or pelvis. The CT data were also evaluated for contrast enhancement, slice thickness, radiation dose, and reason for subsequent CT exam. Over 3 years, 290 of the 1,239 (24%) spine CT exams were followed by CT of the same anatomic region to evaluate extraspinal anatomy. The use or nonuse of contrast in these follow-up studies was the same as the preceding spine study in 91 cases, which were repeated on the same day (n = 37), within 7 days (n = 19), within 8-30 days (n = 15), or after 30 days (n = 20). Fourteen of 25 (56%) T spine CTs and 34 of 52 (65%) L spine CTs without contrast were followed by a chest CT or abdomen/pelvis CT without contrast within 7 days, respectively. Among 31 pediatric exams, 6 of 31 (19%) spine CTs were followed by a CT of the same anatomic region, all within 7 days. Reconstructing full FOV images of spine CT scans in addition to the standard coned down spine FOV may reduce redundant CT imaging and radiation dose.


Assuntos
Vértebras Lombares/diagnóstico por imagem , Doenças da Coluna Vertebral/diagnóstico por imagem , Vértebras Torácicas/diagnóstico por imagem , Tomografia Computadorizada por Raios X/estatística & dados numéricos , Adolescente , Adulto , Idoso , Idoso de 80 Anos ou mais , Criança , Pré-Escolar , Intervalos de Confiança , Meios de Contraste , Feminino , Humanos , Lactente , Masculino , Pessoa de Meia-Idade , Doses de Radiação , Radiografia Abdominal , Radiografia Torácica , Estudos Retrospectivos
7.
Front Cardiovasc Med ; 9: 1045730, 2022.
Artigo em Inglês | MEDLINE | ID: mdl-36386377

RESUMO

Background: Obesity is a risk factor for atrial fibrillation (AF) and strongly influences the response to treatment. Atrial fibrosis shows similar associations. Epicardial adipose tissue (EAT) may be a link between these associations. We sought to assess whether EAT is associated with body mass index (BMI), left atrial (LA) fibrosis and volume. Methods: LA fibrosis and EAT were assessed using late gadolinium enhancement, and Dixon MRI sequences, respectively. We derived 3D models incorporating fibrosis and EAT, then measured the distance of fibrotic and non-fibrotic areas to the nearest EAT to assess spatial colocalization. Results: One hundred and three AF patients (64% paroxysmal, 27% female) were analyzed. LA volume index was 54.9 (41.2, 69.7) mL/m2, LA EAT index was 17.4 (12.7, 22.9) mL/m2, and LA fibrosis was 17.1 (12.4, 23.1)%. LA EAT was significantly correlated with BMI (R = 0.557, p < 0.001); as well as with LA volume and LA fibrosis after BSA adjustment (R = 0.579 and R = 0.432, respectively, p < 0.001 for both). Multivariable analysis showed LA EAT to be independently associated with LA volume and fibrosis. 3D registration of fat and fibrosis around the LA showed no clear spatial overlap between EAT and fibrotic LA regions. Conclusion: LA EAT is associated with obesity (BMI) as well as LA volume and fibrosis. Regions of LA EAT did not colocalize with fibrotic areas, suggesting a systemic or paracrine mechanism rather than EAT infiltration of fibrotic areas.

8.
Radiology ; 257(2): 541-8, 2010 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-20829542

RESUMO

PURPOSE: To assess the usefulness of ordinal scoring of the visual assessment of coronary artery calcification (CAC) on low-dose computed tomographic (CT) scans of the chest in the prediction of cardiovascular death. MATERIALS AND METHODS: All participants consented to low-dose CT screening according to an institutional review board-approved protocol. The amount of CAC was assessed on ungated low-dose CT scans of the chest obtained between June 2000 and December 2005 in a cohort of 8782 smokers aged 40-85 years. The four main coronary arteries were visually scored, and each participant received a CAC score of 0-12. The date and cause of death was obtained by using the National Death Index. Follow-up time (median, 72.3 months; range, 0.3-91.9 months) was calculated as the time between CT and death, loss to follow-up, or December 31, 2007, whichever came first. Logistic regression analysis was used to determine the risk of mortality according to CAC category adjusted for age, pack-years of cigarette smoking, and sex. The same analysis to determine the hazard ratio for survival from cardiac death was performed by using Cox regression analysis. RESULTS: The rate of cardiovascular deaths increased with an increasing CAC score and was 1.2% (43 of 3573 subjects) for a score of 0, 1.8% (66 of 3569 subjects) for a score of 1-3, 5.0% (51 of 1015 subjects) for a score of 4-6, and 5.3% (33 of 625 subjects) for a score of 7-12. With use of subjects with a CAC score of 0 as the reference group, a CAC score of at least 4 was a significant predictor of cardiovascular death (odds ratio [OR], 4.7; 95% confidence interval: 3.3, 6.8; P < .0001); when adjusted for sex, age, and pack-years of smoking, the CAC score remained significant (OR, 2.1; 95% confidence interval: 1.4, 3.1; P = .0002). CONCLUSION: Visual assessment of CAC on low-dose CT scans provides clinically relevant quantitative information as to cardiovascular death.


Assuntos
Calcinose/diagnóstico por imagem , Doenças Cardiovasculares/mortalidade , Doença da Artéria Coronariana/diagnóstico por imagem , Doença da Artéria Coronariana/mortalidade , Tomografia Computadorizada por Raios X , Adulto , Fatores Etários , Idoso , Idoso de 80 Anos ou mais , Calcinose/mortalidade , Distribuição de Qui-Quadrado , Feminino , Humanos , Modelos Logísticos , Masculino , Pessoa de Meia-Idade , Valor Preditivo dos Testes , Prognóstico , Modelos de Riscos Proporcionais , Fatores de Risco , Fumar/efeitos adversos
9.
Magn Reson Med ; 63(3): 736-44, 2010 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-20187182

RESUMO

Blood suppression in the lower extremities using flow-reliant methods such as double inversion recovery may be problematic due to slow blood flow. T(2) mapping using fast spin echo (FSE) acquisition was utilized to quantitate the effectiveness of double inversion recovery blood suppression in 13 subjects and showed that 25 +/- 12% of perceived vessel wall pixels in the popliteal arteries contained artifactual blood signal. To overcome this problem, a flow-insensitive T(2)-prepared inversion recovery sequence was implemented and optimal timing parameters were calculated for FSE acquisition. Black blood vessel wall imaging of the popliteal and femoral arteries was performed using two-dimensional T(2)-prepared inversion recovery-FSE in the same 13 subjects. Comparison with two-dimensional double inversion recovery-FSE showed that T(2)-prepared inversion recovery-FSE reduced wall-mimicking blood artifacts that inflated double inversion recovery-FSE vessel wall area measurements in the popliteal artery.


Assuntos
Artérias/anatomia & histologia , Artérias/fisiologia , Interpretação de Imagem Assistida por Computador/métodos , Angiografia por Ressonância Magnética/métodos , Adulto , Velocidade do Fluxo Sanguíneo/fisiologia , Feminino , Humanos , Aumento da Imagem/métodos , Masculino , Pessoa de Meia-Idade , Reprodutibilidade dos Testes , Sensibilidade e Especificidade , Adulto Jovem
10.
J Magn Reson Imaging ; 31(4): 845-53, 2010 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-20373428

RESUMO

PURPOSE: To evaluate the clinical performance of a novel automated left ventricle (LV) segmentation algorithm (LV-METRIC) that involves no geometric assumptions. MATERIALS AND METHODS: LV-METRIC and manual tracing (MT) were used independently to quantify LV volumes and LVEF (ejection fraction) for 151 consecutive patients who underwent cine-CMR (steady-state free precession). Phase contrast imaging was used to independently measure stroke volume. RESULTS: LV-METRIC was successful in all cases. Mean LVEF was within 1 point of MT (Delta 0.6 +/- 2.3%, P < 0.05), with smaller differences among patients with (0.5 +/- 2.5%) versus those without (0.9 +/- 2.3%; P = 0.01) advanced systolic dysfunction (LVEF

Assuntos
Ventrículos do Coração/patologia , Imageamento por Ressonância Magnética/métodos , Miocárdio/patologia , Função Ventricular Esquerda , Adulto , Idoso , Algoritmos , Automação , Feminino , Ventrículos do Coração/anatomia & histologia , Humanos , Processamento de Imagem Assistida por Computador , Masculino , Pessoa de Meia-Idade , Reprodutibilidade dos Testes
11.
Eur Heart J Case Rep ; 4(6): 1-5, 2020 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-33442653

RESUMO

BACKGROUND: Thyroid storm is a rare condition with well-known cardiovascular manifestations including tachycardia, atrial fibrillation, heart failure, and myocardial infarction (MI). Several uncommon conditions that can mimic MI are associated with thyrotoxicosis and discussed in this case. CASE SUMMARY: A 23-year-old previously healthy male presented after the onset of generalized weakness and inability to rise from bed in the setting of 35 kg of unintentional weight loss, and was found to have profound hypokalaemia, elevated thyroid hormone, and suppressed thyroid-stimulating hormone consistent with thyrotoxicosis secondary to Grave's disease. Following hospital admission, he developed worsening tachycardia with dynamic anteroseptal ST-segment elevations and elevated cardiac biomarkers concerning for MI. He was treated with aspirin, ticagrelor, and a heparin infusion, but was unable to tolerate beta-blockade acutely due to hypotension. Echocardiography demonstrated a severely dilated left ventricle (left ventricular end-diastolic volume index 114 mL/m2) and severely reduced systolic function (ejection fraction 23%) with global hypokinesis. Following initiation of propylthiouracil, iodine solution, and stress-dosed steroids his tachycardia and ST-elevations resolved. Computed tomography (CT) coronary angiography demonstrated no evidence of coronary stenosis. He was discharged on methimazole, metoprolol, and lisinopril and found to have recovered left ventricular systolic function at 2-month follow-up. DISCUSSION: Thyrotoxicosis can rarely cause coronary vasospasm, stress cardiomyopathy, and autoimmune myocarditis. These conditions should be suspected in hyperthyroid patients with features of MI and normal coronary arteries. Workup should include laboratory evaluation, electrocardiography (ECG), echocardiography, and non-invasive or invasive ischaemic evaluation.

12.
Clin Imaging ; 62: 76-80, 2020 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-32200203

RESUMO

RATIONALE OBJECTIVES: Excess z-axis scanning continues as an unnecessary source of radiation. This study seeks to determine patient, technologist and CT factors that affect excess scan length for chest CT. MATERIALS AND METHODS: Retrospective evaluation of 1118 consecutive noncontrast chest CT scans, over twelve consecutive months, was performed for evaluation of scan length above and below the lung parenchyma. Scan length >2 cm was considered excessive. Bivariate analysis for mean excess scan length and presence of excess scan length analyzed technologist's exam volume during the study period, patient age, patient gender, day of week, and time of day as categorical variables. Technologists performing >100 chest CT scans during the study period were considered high-volume while all others were considered low-volume. RESULTS: Mean excess scan length was 5 mm, 29 mm, and 33 mm above the lungs, below the lungs, and total. 81% and 95% of studies had excess scanning above the lungs and below the lungs respectively. Multivariable analysis showed that high volume technologists, male patients, and patients younger than 65 had a greater amount of excess scan length and presence of excessive scanning above the lungs; high volume technologists and male patients had a greater amount of excess scan length below the lungs, and high volume technologists and patients older than 65 had greater presence of excessive scanning below the lungs, each p < 0.001. CONCLUSIONS: Excess scanning on chest CT is common, varies by patient age and gender and was significantly greater for high volume technologists.


Assuntos
Tomografia Computadorizada por Raios X , Adulto , Feminino , Humanos , Pulmão/diagnóstico por imagem , Masculino , Pessoa de Meia-Idade , Pacientes Ambulatoriais , Doses de Radiação , Cintilografia , Estudos Retrospectivos
13.
AJR Am J Roentgenol ; 193(4): 1090-6, 2009 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-19770333

RESUMO

OBJECTIVE: The objectives of this study were to prospectively evaluate changes in tumor perfusion after chemoradiation therapy and to investigate the feasibility of perfusion CT for prediction of early tumor response and prognosis of non-small cell lung cancer. SUBJECTS AND METHODS: Perfusion CT was performed on an MDCT scanner with 50 mL of iodinated contrast material injected at 4 mL/s. The quality of each functional map was rated from 0 to 3 for 123 patients with confirmed lung cancer. A subset of images was independently reviewed by two radiologists to measure interobserver and intraobserver variability. Perfusion parameters and tumor response were assessed for 35 patients with non-small cell lung cancer who underwent chemoradiation therapy. Progression-free survival and overall survival were analyzed for 22 patients who underwent repeated perfusion CT after therapy. RESULTS: Image quality was graded 2 (moderate) or 3 (good) in 68.2% of cases. High interobserver and intraobserver correlations of perfusion parameters were found on qualified images. The patients who responded to chemoradiation therapy had significantly greater blood flow (p = 0.023) than patients who did not respond. The median progression-free survival period of the patients with an increased permeability-surface area product was 4.7 months, significantly lower than the median progression-free survival period of 19.0 months among patients with a decreased permeability-surface area product (p < 0.001). The median overall survival period was 10.6 months for the group with an increased permeability-surface area product, significantly lower than the 19.3 months for the group with a decreased permeability-surface area product (p = 0.004). CONCLUSION: Non-small cell lung cancer with higher perfusion is more sensitive to chemoradiation therapy than that with lower perfusion. After chemoradiation therapy, findings at perfusion CT are a significant predictor of early tumor response and overall survival among patients with non-small cell lung cancer.


Assuntos
Antineoplásicos/uso terapêutico , Carcinoma Pulmonar de Células não Pequenas/diagnóstico por imagem , Carcinoma Pulmonar de Células não Pequenas/terapia , Neoplasias Pulmonares/diagnóstico por imagem , Neoplasias Pulmonares/terapia , Imagem de Perfusão/métodos , Radioterapia Conformacional , Tomografia Computadorizada por Raios X/métodos , Terapia Combinada , Humanos , Prognóstico , Reprodutibilidade dos Testes , Sensibilidade e Especificidade , Resultado do Tratamento
15.
Radiology ; 248(3): 1004-12, 2008 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-18710989

RESUMO

UNLABELLED: This retrospective analysis of existing patient data had institutional review board approval and was performed in compliance with HIPAA. No informed consent was required. The purpose of the study was to develop and validate an algorithm for automated segmentation of the left ventricular (LV) cavity that accounts for papillary and/or trabecular muscles and partial voxels in cine magnetic resonance (MR) images, an algorithm called LV Myocardial Effusion Threshold Reduction with Intravoxel Computation (LV-METRIC). The algorithm was validated in biologic phantoms, and its results were compared with those of manual tracing, as well as those of a commercial automated segmentation software (MASS [MR Analytical Software System]), in 38 subjects. LV-METRIC accuracy in vitro was 98.7%. Among the 38 subjects studied, LV-METRIC and MASS ejection fraction estimations were highly correlated with manual tracing (R(2) = 0.97 and R(2) = 0.95, respectively). Ventricular volume estimations were smaller with LV-METRIC and larger with MASS than those calculated by using manual tracing, though all results were well correlated (R(2) = 0.99). LV-METRIC volume measurements without partial voxel interpolation were statistically equivalent to manual tracing results (P > .05). LV-METRIC had reduced intraobserver and interobserver variability compared with other methods. MASS required additional manual intervention in 58% of cases, whereas LV-METRIC required no additional corrections. LV-METRIC reliably and reproducibly measured LV volumes. SUPPLEMENTAL MATERIAL: http://radiology.rsnajnls.org/cgi/content/full/248/3/1004/DC1.


Assuntos
Ventrículos do Coração/patologia , Aumento da Imagem/métodos , Interpretação de Imagem Assistida por Computador/métodos , Imageamento Tridimensional/métodos , Imageamento por Ressonância Magnética/métodos , Reconhecimento Automatizado de Padrão/métodos , Disfunção Ventricular Esquerda/diagnóstico , Algoritmos , Inteligência Artificial , Feminino , Humanos , Masculino , Reprodutibilidade dos Testes , Sensibilidade e Especificidade
16.
J Hypertens ; 26(8): 1677-85, 2008 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-18622248

RESUMO

BACKGROUND: Accurate quantification of left ventricular mass and ejection fraction is important for patients with left ventricular hypertrophy. Although cardiac magnetic resonance imaging has been proposed as a standard for these indices, prior studies have variably included papillary muscles and trabeculae in myocardial volume. This study investigated the contribution of papillary muscles and trabeculae to left ventricular quantification in relation to the presence and pattern of hypertrophy. METHODS: Cardiac magnetic resonance quantification was performed on patients with concentric or eccentric hypertrophy and normal controls (20 per group) using two established methods that included papillary muscles and trabeculae in myocardium (method 1) or intracavitary (method 2) volumes. RESULTS: Among all patients, papillary muscles and trabeculae accounted for 10.5% of ventricular mass, with greater contribution with left ventricular hypertrophy than normals (12.6 vs. 6.2%, P < 0.001). Papillary muscles and trabeculae mass correlated with ventricular wall mass (r = 0.53) and end-diastolic volume (r = 0.52; P < 0.001). Papillary muscles and trabeculae inclusion in myocardium (method 1) yielded smaller differences with a standard of mass quantification from linear ventricular measurements than did method 2 (P < 0.001). Method 1 in comparison with method 2 yielded differences in left ventricular mass, ejection fraction and volume in all groups, especially in patients with hypertrophy: the difference in ventricular mass index was three-fold to six-fold greater in hypertrophy than normal groups (P < 0.001). Difference in ejection fraction, greatest in concentric hypertrophy (P < 0.001), was independently related to papillary muscles and trabeculae mass, ventricular wall mass, and smaller ventricular volume (R = 0.56, P < 0.001). CONCLUSION: Established cardiac magnetic resonance methods yield differences in left ventricular quantification due to variable exclusion of papillary muscles and trabeculae from myocardium. The relative impact of papillary muscles and trabeculae exclusion on calculated mass and ejection fraction is increased among patients with hypertrophy-associated left ventricular remodeling.


Assuntos
Hipertrofia Ventricular Esquerda/patologia , Imageamento por Ressonância Magnética/métodos , Imageamento por Ressonância Magnética/normas , Miocárdio/patologia , Músculos Papilares/patologia , Idoso , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Valor Preditivo dos Testes , Reprodutibilidade dos Testes , Remodelação Ventricular
17.
AJR Am J Roentgenol ; 191(1): 38-42, 2008 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-18562722

RESUMO

OBJECTIVE: The purpose of this study was to compare whole-heart acquisition with targeted-volume acquisition in 3-T navigator coronary MR angiography with parallel imaging. SUBJECTS AND METHODS: The right and left coronary arteries of 20 subjects were imaged with axial whole-heart acquisition and two oblique targeted-volume acquisitions. RESULTS: Both whole-heart and targeted-volume acquisitions were completed with similar navigator efficiencies ( approximately 50%) and depicted similar coronary artery diameters ( approximately 3 mm) (p >or= 0.06). The lengths of the coronary arteries were not significantly different (p = 0.07-0.45) for the whole-heart and targeted-volume approaches. Depiction of the sharper coronary arteries (p

Assuntos
Doença da Artéria Coronariana/diagnóstico , Interpretação de Imagem Assistida por Computador/métodos , Imageamento Tridimensional/métodos , Miocárdio/patologia , Adulto , Idoso , Humanos , Angiografia por Ressonância Magnética , Pessoa de Meia-Idade , Reprodutibilidade dos Testes , Sensibilidade e Especificidade
18.
J Thorac Imaging ; 33(6): 390-395, 2018 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-30239461

RESUMO

Lung cancer at its earliest stage is typically manifested on computed tomography as a pulmonary nodule, which could be detected by low-dose multidetector computed tomography technology and the use of thinner collimation. Within the last 2 decades, computer-aided detection (CAD) of pulmonary nodules has been developed to meet the increasing demand for lung cancer screening computed tomography with a larger set of images per scan. This review introduced the basic techniques and then summarized the up-to-date applications of CAD systems in clinical and research programs and in the low-dose lung cancer screening trials, especially in the detection of small pulmonary nodules and missed lung cancers. Many studies have already shown that the CAD systems could increase the sensitivity and reduce the false-positive rate in the diagnosis of pulmonary nodules, especially for the small and isolated nodules. Further improvements to the current CAD schemes are needed to detect nodules accurately, particularly for subsolid nodules.


Assuntos
Processamento de Imagem Assistida por Computador/métodos , Neoplasias Pulmonares/diagnóstico por imagem , Nódulos Pulmonares Múltiplos/diagnóstico por imagem , Nódulo Pulmonar Solitário/diagnóstico por imagem , Tomografia Computadorizada por Raios X/métodos , Humanos , Pulmão/diagnóstico por imagem , Sensibilidade e Especificidade
19.
Clin Imaging ; 50: 250-257, 2018.
Artigo em Inglês | MEDLINE | ID: mdl-29704809

RESUMO

OBJECTIVE: To assess causative factors, associated imaging findings, and CT course of round atelectasis (RA). MATERIALS AND METHODS: We retrospectively reviewed CT reports for "round" or "rounded atelectasis" over a 5-year time frame. Patients with at least 2 CT scans a minimum of 6 months apart were included. Electronic medical records and clinical and imaging follow-up was reviewed for all cases. RESULTS: Study population included 50 individuals with mean age of 63 years, and 59 unique instances of RA. The most commonly associated etiologies were hepatic hydrothorax (26%, n = 13) and asbestos exposure (26%), followed by post-infectious pleural inflammation (22%), congestive heart failure (12%), and end stage renal disease (8%). RA was found in the right lower lobe in over half of cases (n = 30). Association with one or more pleural abnormality was identified in all cases, including thickening (88%), fluid (60%), or calcification (40%). Nearly one third (n = 19) demonstrated intra-lesional calcification. In those who underwent PET/CT (20%), lesions demonstrated an average SUV of 2.2 (range 0-7.8). CT course over mean follow up of 32 months (range 6-126 months), demonstrated RA to remain stable (n = 26) or decrease (n = 26) in size in the majority (88%) of cases. CONCLUSION: Round atelectasis may arise from diverse etiologies beyond asbestos, and will most often decrease or remain stable in size over serial exams. Accurate identification may obviate the need for added diagnostic interventions.


Assuntos
Calcinose/diagnóstico por imagem , Pneumopatias/diagnóstico por imagem , Pulmão/diagnóstico por imagem , Tomografia por Emissão de Pósitrons combinada à Tomografia Computadorizada , Atelectasia Pulmonar/diagnóstico por imagem , Tomografia Computadorizada por Raios X , Adulto , Idoso , Amianto/efeitos adversos , Feminino , Humanos , Hidrotórax/complicações , Masculino , Pessoa de Meia-Idade , Atelectasia Pulmonar/etiologia , Estudos Retrospectivos
20.
Clin Imaging ; 50: 235-238, 2018.
Artigo em Inglês | MEDLINE | ID: mdl-29689478

RESUMO

Aorto-atrial fistulas are a rare diagnosis with limited reports in the clinical literature. These findings are often characterized by echocardiography alone; however, the advent and increased availability and use of CT angiography to diagnose cardiac abnormalities provides improved anatomic visibility of potential defects. We are reporting a case of a 76-year-old male with decompensated heart failure secondary to a fistula between the aorta and left atrium after remote history of bioprosthetic aortic valve replacement.


Assuntos
Doenças da Aorta/diagnóstico por imagem , Angiografia por Tomografia Computadorizada , Átrios do Coração/diagnóstico por imagem , Cardiopatias/diagnóstico por imagem , Fístula Vascular/diagnóstico por imagem , Idoso , Ecocardiografia , Próteses Valvulares Cardíacas , Humanos , Masculino
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA