RESUMO
The 2013/59/Euratom Directive reduced the occupational exposure limits for the lens. Since it has become crucial to estimate the dose absorbed by the lens, we have studied the individual variability of exposed workers' ocular conformations with respect to the data estimated from their personal dosimetry. The anterior eye conformations of 45 exposed workers were acquired using Scheimpflug imaging and classified according to their sight conditions (emmetropia, myopia or hypermetropia). Three eye models were computed, with two lens reconstructions, and implemented in an interventional radiology scenario using Monte Carlo code. The models were dosimetrically analysed by simulating setup A, a theoretical monoenergetic and isotropic photon source (10-150 keV) and setup B, a more realistic interventional setting with an angiographic x-ray unit (50, 75, 100 kV peak). Scheimpflug imaging provided an average anterior chamber depth of (6.4 ± 0.5) mm and a lens depth of (3.9 ± 0.3) mm, together with a reconstructed equatorial lens length of (7.1-10.1) mm. Using these data for model reconstruction, dose coefficients (DCs) were simulated for all ocular structures. Regardless of the eye model used, the DCs showed a similar trend with radiation energy, which highlighted that for the same energy and setup, no significant dependence on ocular morphology and workers' visual conditions was observed. The maximum difference obtained did not exceed 1% for all eye models or structures analysed. Therefore, the individual variabilities of worker ocular anatomy do not require any additional correction, compared to the personal dosimetry data measured with a dedicated lens dosimeter. To estimate the dose absorbed by the other eye structures, it is, instead, essential to know the spectrum of the source that has generated the irradiation, since there are differences between monoenergetic sources and more realistic angiographic units.
Assuntos
Cristalino , Exposição Ocupacional , Humanos , Método de Monte Carlo , Exposição Ocupacional/análise , Doses de Radiação , Dosímetros de Radiação , Radiologia IntervencionistaRESUMO
This study aimed to investigate if a commercial, knowledge-based tool for radiotherapy planning could be used to estimate the amount of sparing in organs at risk (OARs) in the re-planning strategy for adaptive radiotherapy (ART). Eighty head and neck (HN) VMAT Pareto plans from our institute's database were used to train a knowledge-based planning (KBP) model. An evaluation set of another 20 HN patients was randomly selected. For each patient in the evaluation set, the planning computed tomography (CT) and 2 sets of on-board cone-beam CT, corresponding to the middle and second half of the radiotherapy treatment course, were extracted. The original plan was re-calculated on a daily deformed CT (delivered dose-volume histogram (DVH)) and compared with the KBP DVH predictions and with the final KBP DVH after optimisation of the plan, which was performed on the same image sets. To evaluate the feasibility of this method, the range of KBP DVH uncertainties was compared with the gains obtained from re-planning. DVH differences and receiver operating characteristic (ROC) curve analysis were used for this purpose. On average, final KBP uncertainties were smaller than the gain in re-planning. Statistical tests confirmed significant differences between the two groups. ROC analysis showed KBP performance in terms of area under the curve values higher than 0.7, which confirmed a good accuracy in predicted values. Overall, for 48% of cases, KBP predicted a desirable outcome from re-planning, and the final dose confirmed an effective gain in 47% of cases. We have established a systematic workflow to identify effective OAR sparing in re-planning based on KBP predictions that can be implemented in an on-line, ART process.
Assuntos
Neoplasias de Cabeça e Pescoço , Radioterapia de Intensidade Modulada , Neoplasias de Cabeça e Pescoço/diagnóstico por imagem , Neoplasias de Cabeça e Pescoço/radioterapia , Humanos , Órgãos em Risco , Dosagem Radioterapêutica , Planejamento da Radioterapia Assistida por ComputadorRESUMO
PURPOSE: The software Dosimetry Check (DC) reconstructs the 3D dose distribution on CT images data set by using EPID measured signal. This study aimed to evaluate DC for stereotactic body radiotherapy (SBRT) with unflattened photon beams (FFF) for dosimetric independent plan verification in pre-treatment modality. METHODS: DC v.4.1 was configured for Varian TrueBeam STx FFF beams equipped with EPID aS-1200. The DC FFF models were tested using arc open fields (from 1×1 cm2 to 15×15 cm2) and VMAT (Volumetric Modulated Arc Therapy) SBRT plans on phantom and patient CTs. DC dose distributions (DDC) were compared with that calculated by Eclipse with Acuros XB algorithm (DAXB) and one measured by Octavius 1000 SRS detector (DOCT). All differences were quantified in terms of the local 3D gamma passing rate (%GP), DVH and point dose differences. RESULTS: DC was configured for FFF VMAT using an appropriate correction procedure. %GP2%2mm (mean±standard deviation) of DOCT-DDC was 96.3±2.7% for open fields whereas it was 90.1±5.9% for plans on homogeneous phantom CT. However, average %GP3%3mm of DAXB-DDC was 95.0±4.1 for treatments on patient CT. The fraction of plans passing the %GP3%3mm DQA tolerance level [10% (50%) of maximum dose threshold] were 20/20 (14/20) and 18/20 (16/20) for OCT on phantom CT and DC on patient CT, respectively. CONCLUSIONS: DC characterization for FFF beams was performed. For stereotactic VMAT plan verifications DC showed good agreement with TPS whereas underlined discrepancies with Octavius in the high dose regions. A customized tolerance level is required for EPID-based VMAT FFF pre-treatment verification when DC system is applied.
Assuntos
Radiocirurgia , Radioterapia de Intensidade Modulada , Humanos , Radiometria , Dosagem Radioterapêutica , Planejamento da Radioterapia Assistida por ComputadorRESUMO
The current framework of radiological protection of occupational exposed medical workers reduced the eye-lens equivalent dose limit from 150 to 20 mSv per year requiring an accurate dosimetric evaluation and an increase understanding of radiation induced effects on Lens cells considering the typical scenario of occupational exposed medical operators. Indeed, it is widely accepted that genomic damage of Lens epithelial cells (LEC) is a key mechanism of cataractogenesis. However, the relationship between apoptosis and cataractogenesis is still controversial. In this study biological and physical data are combined to improve the understanding of radiation induced effects on LEC. To characterize the occupational exposure of medical workers during angiographic procedures an INNOVA 4100 (General Electric Healthcare) equipment was used (scenario A). Additional experiments were conducted using a research tube (scenario B). For both scenarios, the frequencies of binucleated cells, micronuclei, p21-positive cells were assessed with different doses and dose rates. A Monte-Carlo study was conducted using a model for the photon generation with the X-ray tubes and with the Petri dishes considering the two different scenarios (A and B) to reproduce the experimental conditions and validate the irradiation setups to the cells. The simulation results have been tallied using the Monte Carlo code MCNP6. The spectral characteristics of the different X-ray beams have been estimated. All irradiated samples showed frequencies of micronuclei and p21-positive cells higher than the unirradiated controls. Differences in frequencies increased with the delivered dose measured with Gafchromic films XR-RV3. The spectrum incident on eye lens and Petri, as estimated with MCNP6, was in good agreement in the scenario A (confirming the experimental setup), while the mean energy spectrum was higher in the scenario B. Nevertheless, the response of LEC seemed mainly related to the measured absorbed dose. No effects on viability were detected. Our results support the hypothesis that apoptosis is not responsible for cataract induced by low doses of X-ray (i.e. 25 mGy) while the induction of transient p21 may interfere with the disassembly of the nuclear envelop in differentiating LEC, leading to cataract formation. Further studies are needed to better clarify the relationship we suggested between DNA damage, transient p21 induction and the inability of LEC enucleation.