Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 6 de 6
Filtrar
Mais filtros

Base de dados
País/Região como assunto
Tipo de documento
Intervalo de ano de publicação
1.
J Hand Surg Am ; 2024 Aug 06.
Artigo em Inglês | MEDLINE | ID: mdl-39115485

RESUMO

PURPOSE: Offering the benefits of rigid fixation while minimizing soft tissue dissection, intramedullary implants have become a popular choice among hand surgeons. Their placement often requires traversing or passing in proximity to joint surfaces. This study aimed to assess the damage to the articular cartilage of the base of the proximal phalanx resulting from antegrade placement of threaded headless intramedullary nails. METHODS: A cadaveric study comparing two techniques for antegrade placement of threaded headless intramedullary nails was conducted in 56 digits. The first entailed a single 2.1 mm intramedullary nail placed via the dorsal base of the proximal phalanx, whereas the second used two 1.8 mm intramedullary nails inserted via the collateral recesses of the phalangeal base. All specimens were analyzed for articular surface damage with the cartilage defect measured as a percentage of total joint surface area. Damage to the extensor tendons was also assessed in a subset of specimens. RESULTS: No significant difference in the percentage of articular surface damage was observed, with an average 3.21% ± 2.34% defect in the single 2.1 mm nail group and a 2.71% ± 3.42% mean defect in the two 1.8 mm nails group. There was no articular surface injury in 18% of digits in each group. Damage to extensor tendons was seen in three (9.4%) specimens and in all cases involved either the extensor indicis proprius or extensor digiti minimi. CONCLUSIONS: Hardware insertion using either the dorsal base of the proximal phalanx or the collateral recesses of the phalangeal base both demonstrated minimal articular cartilage damage and infrequent injury to the extensor tendons. CLINICAL RELEVANCE: With proper technique for antegrade insertion into the proximal phalanx, the cartilage defect observed often encompasses only a small percentage of the overall joint surface area.

2.
Ann Surg ; 278(1): e203-e208, 2023 Jul 01.
Artigo em Inglês | MEDLINE | ID: mdl-35837894

RESUMO

BACKGROUND/OBJECTIVE: Implant-based breast reconstruction is a common plastic surgery procedure with well-documented clinical outcomes. Despite this, the natural history and timing of key complication endpoints are not well described. The goal of this study is to determine when patients are most likely to experience specific adverse events after implant-based reconstruction. METHODS: Retrospective consecutive series of patients who received mastectomy and implant-based reconstruction over a 6-year period were included. Complications and unfavorable outcomes including hematoma, seroma, wound infection, skin flap necrosis, capsular contracture, implant rippling, and implant loss were identified. A time-to-event analysis was performed and Cox regression models identified patient and treatment characteristics associated with each outcome. RESULTS: Of 1473 patients and 2434 total reconstructed breasts, 785 complications/unfavorable outcomes were identified. The 12-month cumulative incidence of hematoma was 1.4%, seroma: 4.3%, infection: 3.2%, skin flap necrosis: 3.9%, capsular contracture: 5.7%, implant rippling: 7.1%, and implant loss: 3.9%. In the analysis, 332/785 (42.3%) complications occurred within 60 days of surgery; 94% of hematomas, 85% of skin necrosis events, and 75% of seromas occurred during this period. Half of all infections and implant losses also occurred within 60 days. Of the remaining complications, 94% of capsular contractures and 93% of implant rippling occurred >60 days from surgery. CONCLUSIONS: Complications following mastectomy and implant-based reconstruction exhibit a discrete temporal distribution. These data represent the first comprehensive study of the timing of adverse events following implant-based reconstruction. These findings are immediately useful to guide postoperative care, follow-up, and clinical trial design.


Assuntos
Implante Mamário , Implantes de Mama , Neoplasias da Mama , Mamoplastia , Humanos , Feminino , Mastectomia/métodos , Implante Mamário/efeitos adversos , Estudos Retrospectivos , Seroma/etiologia , Seroma/complicações , Neoplasias da Mama/complicações , Seguimentos , Mamoplastia/efeitos adversos , Mamoplastia/métodos , Complicações Pós-Operatórias/epidemiologia , Complicações Pós-Operatórias/etiologia , Hematoma/etiologia , Hematoma/complicações , Necrose/complicações , Implantes de Mama/efeitos adversos , Resultado do Tratamento
3.
Semin Plast Surg ; 38(3): 242-252, 2024 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-39118859

RESUMO

Face transplantation (FT) has emerged as a critical intervention for patients with complex facial deformities unsuitable for conventional reconstructive methods. It aims to restore essential functions such as facial expression, mastication, and speech, while also improving psychosocial health. The procedure utilizes various surgical principles, addressing unique challenges of craniofacial complexity and diverse injury patterns. The integration of Computerized Surgical Planning (CSP) leverages computer-aided technologies to enhance preoperative strategy, intraoperative navigation, and postoperative assessment. CSP utilizes three-dimensional computed tomography, printing, angiography, and navigation systems, enabling surgeons to anticipate challenges and reduce intraoperative trial and error. Through four clinical cases, including a groundbreaking combined face and bilateral hand transplant, CSP's role in FT is highlighted by its ability to streamline operative processes and minimize surgical revisions. The adoption of CSP has led to fewer cadaveric rehearsals, heightened operative precision, and greater alignment with preoperative plans. Despite CSP's advancements, it remains complementary to, rather than a replacement for, clinical expertise. The demand for technological resources and multidisciplinary teamwork is high, but the improved surgical outcomes and patient quality of life affirm CSP's value in FT. The technology has become a staple in reconstructive surgery, signaling a step forward in the evolution of complex surgical interventions.

4.
Injury ; 55(2): 111217, 2024 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-38029683

RESUMO

BACKGROUND: An update on the epidemiology of distal radius fractures in the United States is necessary, particularly as the elderly population grows. Additionally, age and frailty have been associated with complications following surgical fixation of DRFs. Herein, we utilize the National Trauma Data Bank, a robust nationwide resource, to investigate the relationship between demographics, comorbidities, injury and fracture characteristics, and admission details. METHODS: Patients with isolated distal radius fractures were identified from the National Trauma Data Bank (2016-2019) according to ICD-10 codes. Univariate and multivariate regressions were conducted to determine independent risk factors for bilateral fractures, displaced fractures, open fractures, as well as length of hospital stay and adverse discharge disposition for patients undergoing inpatient surgical fixation. RESULTS: The incidence of DRFs was 3.6/1,000 trauma-related emergency department visits and 10.8/1,000 upper extremity traumas. Trauma mechanism was significantly associated with displaced and open fractures. Age (OR 1.01, 95% CI 1.01-1.01), BMI (OR 1.02, 95% CI 1.01-1.02), smoking (OR 1.34, 95% CI 1.15-1.57), and alcohol level (trace: OR 2.18, 95% CI 1.41-3.29; intoxicated: OR 2.20, 95% CI 1.63-2.95) were significantly associated with open fractures. Machinery (ß=2.04, 95% CI 1.00-3.08) and MVT (ß=0.39, 95% CI 0.08-0.69) mechanisms were independent risk factors for longer length of stay. mFI-5 was an independent risk factor, in a stepwise fashion, for both length of stay and adverse discharge disposition. CONCLUSIONS: High-energy mechanisms and risk factors for poor skin quality were significantly associated with open fractures. mFI-5 was an independent risk factor for longer length of stay and non-routine discharges in patients of all ages, despite controlling for other comorbidities, unrelated complications, and mechanism of injury. Trauma mechanism was an independent risk factor for prolonged length of stay only, particularly in patients younger than 65 years of age.


Assuntos
Fraturas Expostas , Fraturas do Rádio , Fraturas do Punho , Humanos , Idoso , Estados Unidos/epidemiologia , Fraturas do Rádio/epidemiologia , Fraturas do Rádio/cirurgia , Comorbidade , Fatores de Risco , Estudos Retrospectivos
5.
JPRAS Open ; 41: 244-251, 2024 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-39099676

RESUMO

Background: Vascularized composite allotransplantation (VCA) has become a viable option for restoration of devastating injuries that are not amenable to conventional reconstructive techniques. However, the relative scarcity of procedures performed worldwide, as well as the potential for iatrogenic injury with biopsies, makes studying the immunopathogenesis of acute rejection challenging. Translational VCA research focuses on developing strategies to overcome these barriers with the use of animal models can be technically challenging and difficult to replicate without highly trained microsurgeons. Methods: We describe a modified model of a femur-based composite tissue allograft using an adapted vascular cuff anastomotic technique with a tunneled skin flap in a rodent model. Results: The use of a heterotopic osteomyocutaneous flap with a subcutaneously tunneled-skin paddle to the posterolateral aspect of the recipient rodent allows for ease of flap monitoring and reduces the risk of self-mutilation. A total of six transplantations were conducted with no signs of self-mutilation. Operative time decreased as our surgical technique improved, and long-term graft tolerance was possible under our immunosuppressive regimen. Additionally, we demonstrate cases of successful transplantation in both an allogeneic and syngeneic rodent model. Conclusion: Animal models, although technically challenging, are a reliable and reproducible modality that has been used to investigate various aspects of VCA immunology. We describe the success of an osteomyocutaneous flap with a modified vascular cuff anastomosis that can be used by investigators with less experience in microsurgical techniques to further our understanding of VCA physiology. Furthermore, tunneling of the skin paddle reduces the risk of self-mutilation and other external factors affecting the graft.

6.
Sci Rep ; 12(1): 17512, 2022 10 20.
Artigo em Inglês | MEDLINE | ID: mdl-36266370

RESUMO

With improvement in mastectomy skin flap viability and increasing recognition of animation deformity following sub-pectoral implant placement, there has been a transition toward pre-pectoral breast reconstruction. While studies have explored the cost effectiveness of implant-based breast reconstruction, few investigations have evaluated cost with respect to pre-pectoral versus sub-pectoral breast reconstruction. A retrospective review of 548 patients who underwent mastectomy and implant-based breast reconstruction was performed from 2017 to 2020. The demographic and surgical characteristics of the pre-pectoral and sub-pectoral cohorts were well matched, except for reconstructive staging, as patients who underwent pre-pectoral reconstruction were more likely to undergo single-stage instead of two-stage reconstruction. Comparison of institutional cost ratios by reconstructive technique revealed that the sub-pectoral approach was more costly (1.70 ± 0.44 vs 1.58 ± 0.31, p < 0.01). However, further stratification by laterality and reconstructive staging failed to demonstrate difference in cost by reconstructive technique. These results were confirmed by multivariable linear regression, which did not reveal reconstructive technique to be an independent variable for cost. This study suggests that pre-pectoral breast reconstruction is a cost-effective alternative to sub-pectoral breast reconstruction and may confer cost benefit, as it is more strongly associated with direct-to-implant breast reconstruction.


Assuntos
Implante Mamário , Implantes de Mama , Neoplasias da Mama , Mamoplastia , Humanos , Feminino , Implante Mamário/métodos , Mastectomia/métodos , Neoplasias da Mama/cirurgia , Mamoplastia/métodos , Estudos Retrospectivos , Custos e Análise de Custo
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA