1.
Catheter Cardiovasc Interv ; 96(3): 578-585, 2020 09 01.
Artigo em Inglês | MEDLINE | ID: mdl-31638330

RESUMO

OBJECTIVES: To evaluate myocardial injury and infarction (MI) following elective percutaneous coronary intervention (PCI). BACKGROUND: The substantially higher analytical power of high-sensitivity troponin (hsTn) assays allows detection of minor cardiac troponin (cTn) levels, which may be useful in monitoring myocardial injury and guiding therapies. METHODS: Serial hsTnT measurements were conducted in patients undergoing elective PCI and were related to the extent of coronary artery disease (CAD) as reflected by the SYNTAX score risk categories and American College of Cardiology/American Heart Association classification of coronary lesions. Myocardial injury and MI were diagnosed according to the second and third versions of universal MI definition. RESULTS: The study population consisted of 530 patients, who were grouped into low (41.3%), intermediate (35.4%), and high (23.3%) SYNTAX risk categories. The treated coronary lesions were classified into A 7.8%, B1 24.1%, B2 21.1%, C1 24.6%, and C2 22.4%. Postprocedural hsTnT increases correlated significantly with the complexity of treated coronary lesions (p < .05) and CAD magnitude (p < .05). Rates of MI type 4a according to the second and third MI definition criteria were 98 (27.5%) and 15 (4.2%) cases in patients with normal baseline hsTnT values (N = 357, 67.4%), as well as 137 (79.2%) and 27 (15.6%) cases in those with elevated baseline hsTnT values (N = 173, 32.6%), respectively. CONCLUSIONS: After elective PCI, cTn releases correlate significantly with lesion complexity and CAD extent. Use of hsTnT assay enables precise monitoring of PCI-related myocardial injury and may identify patients at higher risk for ischemic events, who may benefit from potent platelet inhibition, which needs to be investigated in randomized trials.


Assuntos
Doença da Artéria Coronariana/terapia , Infarto do Miocárdio/etiologia , Intervenção Coronária Percutânea/efeitos adversos , Adulto , Idoso , Idoso de 80 Anos ou mais , Biomarcadores/sangue , Doença da Artéria Coronariana/diagnóstico por imagem , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Infarto do Miocárdio/diagnóstico , Valor Preditivo dos Testes , Estudos Prospectivos , Medição de Risco , Fatores de Risco , Fatores de Tempo , Resultado do Tratamento , Troponina T/sangue
2.
J Interv Cardiol ; 31(1): 76-82, 2018 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-29027267

RESUMO

OBJECTIVES: The aim of this study was to assess feasibility and clinical effectiveness of the MitraClip device in octogenarians suffering from severe mitral valve regurgitation due to chordae rupture. BACKGROUND: The MitraClip procedure is a suitable technique in high-risk surgical patients to achieve safe and effective percutaneous repair of mitral valve regurgitation. Octogenarians show cumulative risk and social aspects hindering mitral valve surgery. No data exists regarding the use of the MitraClip device in high-risk octogenarians suffering from mitral valve chordae rupture. METHODS: Between October 2009 and March 2017 98 high-risk octogenarians (society of thoracic surgeons score [STS]: 9.7% ± 0.8) with mitral valve prolapse and consecutively chordae rupture were treated with the MitraClip after interdisciplinary discussion. RESULTS: Successful mitral valve repair was achieved in 91% of the octogenarians. Repair of the mitral valve caused immediate and significant reduction of dyspnoea (NYHA class: 3.5 ± 0.4 vs 2.0 ± 0.3; P < 0.001), cardiac reverse remodeling (LVESD: 39 ± 0.8 vs 35 ± 0.8; P < 0.01) and amelioration of cardiac biomarkers (NTproBNP (4884 ± 52 ng/L vs 2473 ± 210 ng/L; P < 0.05,). Effects were stable over the 12 months observation period. None of our patients died intraprocedurally. CONCLUSIONS: Percutaneous repair of chordae rupture is feasible and safe in high-risk octogenarians. The MitraClip should be considered to repair severe mitral valve regurgitation due to mitral valve chordae rupture in high-risk octogenarians after interdisciplinary discussion even facing a challenging anatomy.


Assuntos
Implante de Prótese de Valva Cardíaca , Anuloplastia da Valva Mitral , Insuficiência da Valva Mitral , Risco Ajustado/métodos , Idoso de 80 Anos ou mais , Estudos de Viabilidade , Feminino , Implante de Prótese de Valva Cardíaca/efeitos adversos , Implante de Prótese de Valva Cardíaca/instrumentação , Implante de Prótese de Valva Cardíaca/métodos , Humanos , Masculino , Valva Mitral/patologia , Valva Mitral/fisiopatologia , Valva Mitral/cirurgia , Anuloplastia da Valva Mitral/efeitos adversos , Anuloplastia da Valva Mitral/métodos , Insuficiência da Valva Mitral/diagnóstico , Insuficiência da Valva Mitral/fisiopatologia , Insuficiência da Valva Mitral/cirurgia , Resultado do Tratamento
3.
Eur Heart J ; 38(39): 2936-2943, 2017 Oct 14.
Artigo em Inglês | MEDLINE | ID: mdl-28431003

RESUMO

AIMS: Intracoronary infusion of autologous nucleated bone marrow cells (BMCs) enhanced the recovery of left ventricular ejection fraction (LVEF) after ST-segment elevation myocardial infarction (STEMI) in the randomised-controlled, open-label BOOST trial. We reassessed the therapeutic potential of nucleated BMCs in the randomised placebo-controlled, double-blind BOOST-2 trial conducted in 10 centres in Germany and Norway. METHODS AND RESULTS: Using a multiple arm design, we investigated the dose-response relationship and explored whether γ-irradiation which eliminates the clonogenic potential of stem and progenitor cells has an impact on BMC efficacy. Between 9 March 2006 and 16 July 2013, 153 patients with large STEMI were randomly assigned to receive a single intracoronary infusion of placebo (control group), high-dose (hi)BMCs, low-dose (lo)BMCs, irradiated hiBMCs, or irradiated loBMCs 8.1 ± 2.6 days after percutaneous coronary intervention (PCI) in addition to guideline-recommended medical treatment. Change in LVEF from baseline (before cell infusion) to 6 months as determined by MRI was the primary endpoint. The trial is registered at Current Controlled Trials (ISRCTN17457407). Baseline LVEF was 45.0 ± 8.5% in the overall population. At 6 months, LVEF had increased by 3.3 percentage points in the control group and 4.3 percentage points in the hiBMC group. The estimated treatment effect was 1.0 percentage points (95% confidence interval, -2.6 to 4.7; P = 0.57). The treatment effect of loBMCs was 0.5 percentage points (-3.0 to 4.1; P = 0.76). Likewise, irradiated BMCs did not have significant treatment effects. BMC transfer was safe and not associated with adverse clinical events. CONCLUSION: The BOOST-2 trial does not support the use of nucleated BMCs in patients with STEMI and moderately reduced LVEF treated according to current standards of early PCI and drug therapy.


Assuntos
Transplante de Medula Óssea/métodos , Infarto do Miocárdio com Supradesnível do Segmento ST/terapia , Células da Medula Óssea/efeitos da radiação , Método Duplo-Cego , Feminino , Raios gama , Humanos , Infusões Intralesionais , Angiografia por Ressonância Magnética , Masculino , Pessoa de Meia-Idade , Intervenção Coronária Percutânea , Transplante de Células-Tronco/métodos , Células-Tronco/efeitos da radiação , Transplante Autólogo , Resultado do Tratamento , Função Ventricular Esquerda/fisiologia
4.
Acta Cardiol ; 73(4): 378-386, 2018 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-29161956

RESUMO

BACKGROUND: Occurrence of severe mitral valve (MV) regurgitation (MR) is an independent negative predictor of mortality in patients with severe systolic heart failure (HF). This study examines clinical effects and cardiac reverse remodelling in patients with severe systolic HF receiving percutaneous mitral valve repair (PMVR) using MitraClip in comparison to patients receiving optimal medical therapy only. METHODS: Between 2010 and 2014, 86 patients (Society of Thoracic Surgeons score: 10.5% ± 1.2%) with severe HF (left ventricular [LV] ejection fraction; LVEF: 25% ± 2%; LV endsystolic diameter [LVESD]: 55 ± 3 mm) and severe MR received PMVR using MitraClip. Cardiac reverse remodelling and clinical parameters were compared to HF patients with severe MR (from our HF outpatient clinic; n = 69; LVEF: 26% ± 1.4%; LVESD: 53 ± 2 mm) receiving optimal medical therapy (OMT) only. All patients received stable OMT and were characterised by echocardiography, 6-minwalk-distance test and cardiac biomarkers within a 24 months observation period. RESULTS: PMVR in patients with end-stage HF and severe MR resulted in reduction of MR and significant additional cardiac reverse remodelling (LVEF: 26 ± 1.4 vs. 33% ± 2%, p < .05; LVESD: 53 ± 2 vs. 47 ± 2 mm, p < .05) over the 24 months observation period as compared to pharmacologically-only managed comparators. CONCLUSIONS: Both OMT and PMVR cause cardiac reverse remodelling and relief of symptoms in patients with HF and severe MR. PMVR results in significant additional cardiac reverse remodelling compared to pharmacologically-only managed patients.


Assuntos
Antagonistas Adrenérgicos beta/uso terapêutico , Inibidores da Enzima Conversora de Angiotensina/uso terapêutico , Cateterismo Cardíaco/métodos , Insuficiência Cardíaca/complicações , Implante de Prótese de Valva Cardíaca/métodos , Antagonistas de Receptores de Mineralocorticoides/uso terapêutico , Insuficiência da Valva Mitral/cirurgia , Idoso , Ecocardiografia , Feminino , Seguimentos , Alemanha/epidemiologia , Insuficiência Cardíaca/mortalidade , Insuficiência Cardíaca/terapia , Humanos , Masculino , Pessoa de Meia-Idade , Insuficiência da Valva Mitral/complicações , Insuficiência da Valva Mitral/diagnóstico , Estudos Retrospectivos , Índice de Gravidade de Doença , Taxa de Sobrevida/tendências , Resultado do Tratamento , Função Ventricular Esquerda/fisiologia
5.
J Interv Cardiol ; 30(1): 72-78, 2017 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-27882613

RESUMO

OBJECTIVES: In this study, we compare procedural results of our first Evolut R (Medtronic, Minneapolis, MN, USA) implantations with the last CoreValve implantations. Main endpoints include paravalvular regurgitation, major vascular complications, stroke, and pacemaker implantation. BACKGROUND: The evolution of transcatheter aortic valve replacement (TAVR) was possible due to various technical improvements, leading to better periprocedural and long-term outcome. The newly designed Evolut R valve has the potential to further improve TAVR's performance. METHODS: We retrospectively analyzed our first 100 consecutive patients who received the Evolut R valve with the last 100 consecutive patients who received the CoreValve prosthesis between July 2013 and February 2016. Only patients treated with a 26 mm or 29 mm bioprosthesis were included. RESULTS: No significant differences in patient characteristics were noticed. Both angiography and echocardiography after TAVR showed significantly higher rates of "none or trace" regurgitation in the Evolut R group (angiography: 67% Evolut R vs. 29.3% CoreValve; P < 0.001; echocardiography: 68% Evolut R vs. 46.5% CoreValve; P < 0.05). No significant differences were seen in 30-day mortality (7% CoreValve vs. 1% Evolut R), stroke rates (3% CoreValve vs. 2% Evolut R), pacemaker implantation rates (24% CoreValve vs. 23% Evolut R), and major vascular complications (6% CoreValve vs. 1% Evolut R). Implantations were significantly higher with the Evolut R prosthesis. CONCLUSIONS: TAVR with the new Evolut R resulted in significantly lower paravalvular regurgitation. This may be due to redesigned cell geometry and higher precision during implantations, as well as the ability to resheath a malpositioned valve.


Assuntos
Estenose da Valva Aórtica/cirurgia , Valva Aórtica , Bioprótese , Próteses Valvulares Cardíacas , Substituição da Valva Aórtica Transcateter , Idoso , Idoso de 80 Anos ou mais , Insuficiência da Valva Aórtica/etiologia , Estenose da Valva Aórtica/diagnóstico por imagem , Ecocardiografia , Feminino , Humanos , Masculino , Desenho de Prótese , Estudos Retrospectivos , Resultado do Tratamento
6.
Acta Cardiol ; 72(4): 474-482, 2017 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-28705072

RESUMO

Background Vascular injury and access site complications in the contemporary setting of transcatheter aortic valve implantation (TAVI) are known to be associated with increased mortality and morbidity. The aim of our study was to analyse the feasibility and safety of percutaneous treatment of such vascular complications using a stent graft. Methods Between January 2010 and April 2013, 36 TAVI patients developed severe access site complications and underwent subsequent interventional treatment with a covered stent. Acute treatment success was confirmed by angiography immediately after the implantation of the stent graft, with clinical long-term patency follow-up being assessed by duplex ultrasound. Results Of the 36 patients evaluated, percutaneous treatment of the acute access site bleeding was successful in 35 patients (97%), with one patient requiring surgical intervention due to insufficient haemostasis after stent graft implantation. A subset of 5 patients underwent successful ipsilateral stent graft implantation, either because crossover sheath placement was not feasible (n = 1), or intentionally with an even sheathless approach in an effort to reduce vessel injury (n = 4). After a mean follow-up of 22 ± 8 months, stent graft patency was confirmed by duplex ultrasound in 13 patients with an additional 5 patients reporting to be free from symptoms and claudication. Thirteen patients died within the first 24 months after the procedure, however, none was due to access vessel complications. Five patients were lost for follow-up. Conclusions Our data confirm that endovascular treatment of access site complications related to TAVI is feasible, safe and efficacious, resulting in long-term vascular patency.


Assuntos
Implante de Prótese Vascular , Cateterismo Periférico/efeitos adversos , Procedimentos Endovasculares , Artéria Femoral/cirurgia , Complicações Pós-Operatórias/cirurgia , Substituição da Valva Aórtica Transcateter/efeitos adversos , Idoso , Idoso de 80 Anos ou mais , Angiografia , Prótese Vascular , Implante de Prótese Vascular/efeitos adversos , Implante de Prótese Vascular/instrumentação , Procedimentos Endovasculares/efeitos adversos , Procedimentos Endovasculares/instrumentação , Estudos de Viabilidade , Feminino , Artéria Femoral/diagnóstico por imagem , Artéria Femoral/fisiopatologia , Humanos , Masculino , Complicações Pós-Operatórias/diagnóstico por imagem , Complicações Pós-Operatórias/etiologia , Complicações Pós-Operatórias/fisiopatologia , Punções , Stents , Fatores de Tempo , Resultado do Tratamento , Ultrassonografia Doppler Dupla , Grau de Desobstrução Vascular
7.
J Mol Cell Cardiol ; 85: 117-26, 2015 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-26031702

RESUMO

AIM OF THE STUDY: Capillary/myocyte mismatch is a hallmark of maladaptive myocardial hypertrophy, but the exact mechanisms of this phenomenon remain unknown. We therefore aimed to evaluate the role of calcineurin A in the regulation of hypoxia-inducible factor-1 alpha (HIF-1 alpha) in a calcineurin overexpressing mouse model of myocardial hypertrophy. METHODS AND RESULTS: Mice overexpressing calcineurin A (CnATg) showed persistent upregulation of HIF-1 alpha protein without evidence of a reduction in capillary density despite progressive myocardial hypertrophy. Likewise, overexpression of calcineurin A in isolated cardiomyocytes induced upregulation of HIF-1 alpha protein. In contrast, NFAT-overexpression had no such effect, implying that NFAT-independent mechanisms were responsible for increased HIF-1 alpha levels. In addition, inhibition of HSP90 via the HSP90-inhibitor 17-AAG or siRNA abolished calcineurin A-induced upregulation of HIF-1 alpha. Consequently, upregulation of HIF-1 alpha target genes like VEGF-A, BNIP-3 or PGK-1 was also inhibited by either 17-AAG or siRNA directed against HSP90. Finally, when CnATg mice were treated with 17-AAG, they demonstrated reduced left ventricular function and capillary density. CONCLUSIONS: We describe here for the first time that overexpression of the phosphatase calcineurin A prevents the development of a capillary/myocyte mismatch despite progressive myocardial hypertrophy. This effect was mediated by HSP-90 induced stabilization of HIF-1 alpha. Further work is needed to understand this unexpected cardioprotective effect of calcineurin A.


Assuntos
Calcineurina/metabolismo , Cardiomegalia/metabolismo , Proteínas de Choque Térmico HSP90/fisiologia , Subunidade alfa do Fator 1 Induzível por Hipóxia/metabolismo , Animais , Núcleo Celular/metabolismo , Células Cultivadas , Vasos Coronários/patologia , Regulação para Baixo , Subunidade alfa do Fator 1 Induzível por Hipóxia/genética , Masculino , Camundongos Endogâmicos C57BL , Camundongos Transgênicos , Microvasos/patologia , Fatores de Transcrição NFATC/metabolismo , Estabilidade Proteica , Ratos Wistar , Transcrição Gênica
8.
J Interv Cardiol ; 28(1): 109-16, 2015 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-25689554

RESUMO

BACKGROUND: TAVR has become an established treatment for severe symptomatic aortic stenosis in patients with high surgical risk. The latest generation of the balloon-expandable Edwards Sapien device, the Sapien 3, together with its new transfemoral Commander delivery system has been designed to reduce paravalvular regurgitation and vascular access site complications. OBJECTIVES: To evaluate procedural results and short term outcome with the third generation Sapien 3 device. METHODS: We retrospectively evaluated 125 consecutive TAVR patients and analyzed the first 51 patients in whom we implanted the new Sapien 3 device via transfemoral access. RESULTS: In patients implanted with the Sapien 3 device significant residual paravalvular regurgitation after TAVR was virtually absent with the vast majority having none or trace postinterventional aortic regurgitation on angiography or echocardiography (92.2% and 80.4% respectively). None of the patients had more than mild paravalvular regurgitation. Major vascular access site complications or major bleeding according to the VARC II criteria were not observed in our cohort, minor vascular complications and minor bleeding occurred in 7.8% and 5.9% respectively. If vascular complications occurred, they were related to closure device failure. Thirty day outcome showed a 1.9% major stroke rate and 3.9% death rate. However, we observed a 25.5% permanent pacemaker rate in our Sapien 3 cohort. CONCLUSIONS: Implantation of the new third generation Sapien 3 device resulted in excellent procedural and short term outcome. Significant paravalvular regurgitation was virtually absent. However, the increased rate of postinterventional pacemaker implantations needs to be analyzed in a larger cohort of patients.


Assuntos
Estenose da Valva Aórtica/cirurgia , Bioprótese , Próteses Valvulares Cardíacas , Substituição da Valva Aórtica Transcateter/métodos , Idoso de 80 Anos ou mais , Insuficiência da Valva Aórtica/cirurgia , Aortografia , Feminino , Humanos , Masculino , Marca-Passo Artificial/estatística & dados numéricos , Avaliação de Resultados da Assistência ao Paciente , Ajuste de Prótese , Estudos Retrospectivos
9.
J Interv Cardiol ; 27(2): 191-8, 2014 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-24433399

RESUMO

BACKGROUND: Transcatheter aortic valve implantation has become an established treatment for severe aortic stenosis in patients with high surgical risk. Due to its specific design, the self-expanding 31 mm CoreValve prosthesis can be technically challenging. This is especially true for patients with large annuli above 27.5 mm for which the CoreValve 31 mm device is the only option. OBJECTIVES: To evaluate procedural results and short-term outcome with the 31 mm CoreValve device in patients with large annuli. METHODS: We retrospectively analyzed 54 patients in whom we implanted a 31 mm self-expanding CoreValve bioprosthesis and compared them to 50 consecutive patients implanted with the smaller 29 mm device within the same period of time. RESULTS: Patients with the 31 mm prosthesis had significantly higher rates of postinterventional pacemaker implantations (35% vs. 20%; P = 0.036) despite similar implantation depths (6.5 ± 4 vs. 7.5 ± 4; P = 0.34). However, the number of deep implantations (>8 mm) was significantly higher (P = 0.045). No significant difference could be observed with respect to cases with ≥Grade 2 postinterventional aortic regurgitation (8% vs. 12.9%; P = 0.5294). Major vascular complications (4% vs. 3.7%; P = ns), 30-day mortality (8% vs. 7.7%; P = ns), and major stroke (3.8% vs. 2%; P = ns) were not different between the 2 groups. CONCLUSION: Despite the technical challenges, procedural results with the 31 mm self-expanding CoreValve prosthesis in large anatomies were similar to those with the smaller sized 29 mm version of the device. However, postinterventional pacemaker rates were significantly higher in the 31 mm cohort despite comparable implantation depths, which might be the result of the specific design of the device.


Assuntos
Valva Aórtica/anatomia & histologia , Bioprótese , Idoso , Idoso de 80 Anos ou mais , Insuficiência da Valva Aórtica/cirurgia , Feminino , Humanos , Masculino , Desenho de Prótese , Implantação de Prótese , Estudos Retrospectivos , Resultado do Tratamento
10.
Mediators Inflamm ; 2014: 576482, 2014.
Artigo em Inglês | MEDLINE | ID: mdl-25089077

RESUMO

BACKGROUND: TNF-like weak inducer of apoptosis (TWEAK) has been reported to predict mortality in patients with dilated cardiomyopathy. However, whether it can be used as a biomarker for disease monitoring or rather represents a risk factor for disease progression remains unclear. AIM OF THE STUDY: To evaluate the potential of sTWEAK as a biomarker in patients with dilated cardiomyopathy. RESULTS: We conducted a serial study of sTWEAK levels in 78 patients with dilated cardiomyopathy. Soluble TWEAK levels predicted not only a combined mortality/heart transplantation endpoint after 4 years (P = 0.0001), but also the risk for clinical deterioration (P = 0.0001). Compared to NT-proBNP, sTWEAK remained relatively stable in individual patients on follow-up indicating that inter- rather than intraindividual differences in sTWEAK levels predicted outcome. Finally, neither did the scavenger receptor sCD163 correlate with sTWEAK levels nor did its determination add additional information on outcome in patients with dilated cardiomyopathy. CONCLUSION: Soluble TWEAK levels in patients with dilated cardiomyopathy may not be of value for disease monitoring but may represent a risk factor for disease progression and death. Further research will be necessary to elucidate the exact role of sTWEAK as a potential modulator of immune response in the setting of dilated cardiomyopathy.


Assuntos
Biomarcadores/sangue , Cardiomiopatia Dilatada/sangue , Fatores de Necrose Tumoral/sangue , Adulto , Antígenos CD/sangue , Antígenos de Diferenciação Mielomonocítica/sangue , Cardiomiopatia Dilatada/diagnóstico , Citocina TWEAK , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Peptídeo Natriurético Encefálico/sangue , Fragmentos de Peptídeos/sangue , Receptores de Superfície Celular/sangue
11.
Mediators Inflamm ; 2014: 131950, 2014.
Artigo em Inglês | MEDLINE | ID: mdl-24692845

RESUMO

BACKGROUND: TNF-like weak inducer of apoptosis (TWEAK) has recently been shown to be potentially involved in adverse cardiac remodeling. However, neither the exact role of TWEAK itself nor of its receptor Fn14 in this setting is known. AIM OF THE STUDY: To analyze the effects of sTWEAK on myocardial function and gene expression in response to experimental myocardial infarction in mice. RESULTS: TWEAK directly suppressed the expression of PGC-1α and genes of oxidative phosphorylation (OXPHOS) in cardiomyocytes. Systemic sTWEAK application after MI resulted in reduced left ventricular function and increased mortality without changes in interstitial fibrosis or infarct size. Molecular analysis revealed decreased phosphorylation of PI3K/Akt and ERK1/2 pathways associated with reduced expression of PGC-1α and PPARα. Likewise, expression of OXPHOS genes such as atp5O, cycs, cox5b, and ndufb5 was also reduced. Fn14-/- mice showed significantly improved left ventricular function and PGC-1α levels after MI compared to their respective WT littermates (Fn14+/+). Finally, inhibition of intrinsic TWEAK with anti-TWEAK antibodies resulted in improved left ventricular function and survival. CONCLUSIONS: TWEAK exerted maladaptive effects in mice after myocardial infarction most likely via direct effects on cardiomyocytes. Analysis of the potential mechanisms revealed that TWEAK reduced metabolic adaptations to increased cardiac workload by inhibition of PGC-1α.


Assuntos
Infarto do Miocárdio/complicações , Fatores de Necrose Tumoral/metabolismo , Disfunção Ventricular Esquerda/fisiopatologia , Animais , Apoptose/efeitos dos fármacos , Citocina TWEAK , Ecocardiografia , Regulação da Expressão Gênica , Coração/fisiologia , Humanos , Masculino , Camundongos , Infarto do Miocárdio/patologia , Miócitos Cardíacos/citologia , Miócitos Cardíacos/metabolismo , Fosforilação Oxidativa , Ratos , Ratos Sprague-Dawley , Ratos Wistar , Proteínas Recombinantes/metabolismo
12.
Catheter Cardiovasc Interv ; 81(1): 148-59, 2013 Jan 01.
Artigo em Inglês | MEDLINE | ID: mdl-23281089

RESUMO

PURPOSE: To test the ability of a model-based segmentation of the aortic root for consistent assessment of aortic valve structures in patients considered for transcatheter aortic valve implantation (TAVI) who underwent 256-slice cardiac computed tomography (CT). METHODS: Consecutive patients (n = 49) with symptomatic severe aortic stenosis considered for TAVI and patients without aortic stenosis (n = 17) underwent cardiac CT. Images were evaluated by two independent observers who measured the diameter of the aortic annulus and its distance to both coronary ostia (1) manually and (2) software-assisted. All acquired measures were compared with each other and to (3) fully automatic quantification. RESULTS: High correlations were observed for 3D measures of the aortic annulus conducted on multiple oblique planes (r = 0.87 and 0.84 between observers and model-based measures, and r = 0.81 between observers). Reproducibility was further improved by software-assisted versus manual assessment for all the acquired variables (r = 0.98 versus 0.81 for annulus diameter, r = 0.94 versus 0.85 for distance to the left coronary ostium, P < 0.01 for both). Thus, using software-assisted measurements very low limits of agreement were observed for the annulus diameter (95%CI of -1.2 to 0.6 mm) and within very low time-spent (0.6 ± 0.1 min for software-assisted versus 1.6 ± 0.3 min per patient for manual assessment, P < 0.001). Assessment of the aortic annulus using the 3D model-based instead of manual 2D-coronal measurements would have modified the implantation strategy in 12 of 49 patients (25%) with aortic stenosis. Four of 12 patients with potentially modified implantation strategy yielded postprocedural moderate paravalvular regurgitation, which may have been avoided by implantation of a larger prosthesis, as suggested by automatic 3D measures. CONCLUSION: Our study highlights the usefulness of software-assisted preprocedural assessment of the aortic annulus in patients considered for TAVI.


Assuntos
Angiografia/métodos , Cateterismo Cardíaco/métodos , Implante de Prótese de Valva Cardíaca/métodos , Próteses Valvulares Cardíacas , Tomografia Computadorizada por Raios X/métodos , Idoso , Idoso de 80 Anos ou mais , Valva Aórtica/diagnóstico por imagem , Valva Aórtica/fisiopatologia , Estenose da Valva Aórtica , Estudos de Casos e Controles , Estudos de Avaliação como Assunto , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Seleção de Pacientes , Estudos Prospectivos , Interpretação de Imagem Radiográfica Assistida por Computador , Medição de Risco , Índice de Gravidade de Doença , Resultado do Tratamento
13.
J Interv Cardiol ; 25(2): 174-9, 2012 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-22487134

RESUMO

AIMS OF THE STUDY: Transcatheter aortic valve implantation (TAVI) has become an established treatment for severe aortic stenosis in patients with unacceptable high-surgical risk. Recently, the new AccuTrak delivery system for improved deliverability of the CoreValve aortic bioprosthesis was launched. It has not yet been shown if the new delivery catheter leads to optimized positioning and improved procedural outcomes. METHODS AND RESULTS: We conducted a retrospective single-center analysis and evaluated 70 consecutive patients (35 with the original delivery catheter and 35 with the new AccuTrak catheter) for anatomic positioning and related outcome parameters like postinterventional aortic regurgitation (AR) and the need for permanent pacemaker insertion, after CoreValve implantation. The use of the AccuTrak delivery catheter resulted in significantly higher positioning of the CoreValve prosthesis in the left ventricular outflow tract (distance from annulus to lower edge of prosthesis 7.0 mm [5.5 to 9.4 mm] for the AccuTrak group vs. 8.8 mm [7.1 to 11.2 mm] for the original system; median [interquartile range]; P = 0.0068). Moreover, the optimized positioning resulted in reduced rates of significant (≥grade 2) AR assessed by postinterventional aortography and echocardiography (P = 0.044 and P = 0.0275, respectively). Despite improved positioning, no differences in the need for permanent pacemaker implantation were observed. CONCLUSIONS: Our retrospective analysis indicates improved positioning with reduced postinterventional AR with the new CoreValve AccuTrak delivery system. Whether this may also affect the need for permanent pacemaker insertion or long-term outcome after TAVI needs to be evaluated in larger studies.


Assuntos
Estenose da Valva Aórtica/cirurgia , Valva Aórtica , Cateterismo Cardíaco/instrumentação , Catéteres , Implante de Prótese de Valva Cardíaca/instrumentação , Próteses Valvulares Cardíacas , Idoso , Idoso de 80 Anos ou mais , Bioprótese , Angiografia Coronária , Feminino , Implante de Prótese de Valva Cardíaca/métodos , Humanos , Modelos Logísticos , Masculino , Marca-Passo Artificial , Estudos Retrospectivos
14.
J Clin Invest ; 117(11): 3188-97, 2007 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-17975666

RESUMO

Although studies have suggested a role for angiogenesis in determining heart size during conditions demanding enhanced cardiac performance, the role of EC mass in determining the normal organ size is poorly understood. To explore the relationship between cardiac vasculature and normal heart size, we generated a transgenic mouse with a regulatable expression of the secreted angiogenic growth factor PR39 in cardiomyocytes. A significant change in adult mouse EC mass was apparent by 3 weeks following PR39 induction. Heart weight; cardiomyocyte size; vascular density normalization; upregulation of hypertrophy markers including atrial natriuretic factor, beta-MHC, and GATA4; and activation of the Akt and MAP kinase pathways were observed at 6 weeks post-induction. Treatment of PR39-induced mice with the eNOS inhibitor L-NAME in the last 3 weeks of a 6-week stimulation period resulted in a significant suppression of heart growth and a reduction in hypertrophic marker expression. Injection of PR39 or another angiogenic growth factor, VEGF-B, into murine hearts during myocardial infarction led to induction of myocardial hypertrophy and restoration of myocardial function. Thus stimulation of vascular growth in normal adult mouse hearts leads to an increase in cardiac mass.


Assuntos
Cardiomegalia , Coração , Miocárdio , Neovascularização Fisiológica , Proteínas Angiogênicas/genética , Proteínas Angiogênicas/metabolismo , Animais , Cardiomegalia/patologia , Cardiomegalia/fisiopatologia , Células Cultivadas , Ecocardiografia , Células Endoteliais/citologia , Células Endoteliais/metabolismo , Inibidores Enzimáticos/metabolismo , Coração/anatomia & histologia , Hemodinâmica , Camundongos , Camundongos Endogâmicos C57BL , Camundongos Transgênicos , Miocárdio/metabolismo , Miocárdio/patologia , Miócitos Cardíacos/citologia , Miócitos Cardíacos/metabolismo , NG-Nitroarginina Metil Éster/metabolismo , Tamanho do Órgão , Ratos , Ratos Sprague-Dawley , Transgenes
15.
Basic Res Cardiol ; 105(2): 301-13, 2010 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-19629561

RESUMO

Proinflammatory cytokines, including TNF family members, have been shown to play a critical role in cardiac remodeling. FGF-inducible 14-kDa protein (Fn14, TNFrsf12a or TWEAKR) is the smallest member of the TNF-receptor family. Currently, little is known about the functional role of Fn14 and its only known ligand TNF-like weak inducer of apoptosis (TWEAK) in the heart. We therefore evaluated the expression and regulation of Fn14 in cardiomyocytes and in experimental myocardial infarction. In order to study the regulation of Fn14, myocardial infarction was induced in CD-1 mice and neonatal rat cardiomyocytes were used for in vitro studies. TWEAK and Fn14 were markedly upregulated in the remodeling myocardium after experimental myocardial infarction in vivo. Likewise, fibroblast growth factor 1, norepinephrine and angiotensin II as well as mechanical stretch were able to strongly induce Fn14 expression in cardiomyocytes. This induction is mediated via the Rho/ROCK pathway, since the known inhibitors C3 exoenzyme for RhoA and Y27632 for ROCK prevented the upregulation of Fn14 in cardiomyocytes. Consistently, pretreatment of cardiomyocytes with siRNA against Rho A and ROCK also abolished Fn14 induction. Moreover, stimulation of cardiomyocytes with TWEAK promoted nuclear translocation of NF-kappaB and subsequent induction of NF-kappaB dependent genes such as RANTES and MCP-1. Conversely, when cells were pretreated with siRNA against Fn14, NF-kappaB activation by TWEAK was inhibited. We here provide the first evidence of a stress-induced regulation of the TWEAK/Fn14 axis in cardiomyocytes implying a role of the TWEAK/Fn14 pathway in cardiac remodeling.


Assuntos
Miócitos Cardíacos/metabolismo , NF-kappa B/metabolismo , Receptores do Fator de Necrose Tumoral/metabolismo , Quinases Associadas a rho/metabolismo , Proteína rhoA de Ligação ao GTP/metabolismo , Animais , Animais Recém-Nascidos , Células Cultivadas , Fatores de Crescimento de Fibroblastos/metabolismo , Masculino , Camundongos , Infarto do Miocárdio/metabolismo , Ratos , Ratos Wistar , Transdução de Sinais , Receptor de TWEAK , Regulação para Cima
16.
Acta Cardiol ; 75(1): 61-67, 2020 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-30650019

RESUMO

Background: Incidence of stroke within 30 days after percutaneous mitral valve repair using the MitraClip varies from 0.7% and 2.6% between registries. Standard medical treatment after the MitraClip procedure, in the absence of risk factors requiring antithrombotic therapy such as atrial fibrillation, is dual antiplatelet therapy using aspirin and clopidogrel. ESC/EACTS and ACC/AHA surgical guidelines show a Class IIa indication for temporary antithrombotic therapy after mitral valve repair/bioprosthetic valve replacement within the first three months even in patients with no additional risk factors.Methods: 470 patients were treated with the MitraClip receiving oral anticoagulation (Coumadin: INR 2.0-3.0) instead of dual antiplatelet therapy for at least 30 days after the procedure. The incidence of stroke, as well as major adverse events such as bleeding, were analysed in comparison to large registries and multi-centre studies.Results: Incidence of stroke within 30 days was significantly reduced as compared to comparative cohorts (0.2% vs. Median 1.3% [0.7-2.6%]; p < .05). Cardiovascular risk factors such as age, atrial fibrillation, hypertension, diabetes, STS score and prior stroke did not differ significantly between cohorts (ns). Bleeding complications were not increased due to 30 days oral anticoagulation treatment (4.6% vs. Median 7.4% [3.4-13.6%]; ns).Conclusions: Temporary oral anticoagulation might be a strategy to reduce the incidence of stroke within the first 30 days after the MitraClip procedure. Bleeding events were not significantly altered due to temporary oral anticoagulation.


Assuntos
Anticoagulantes/administração & dosagem , Implante de Prótese de Valva Cardíaca/instrumentação , Próteses Valvulares Cardíacas , Insuficiência da Valva Mitral/cirurgia , Valva Mitral/cirurgia , Acidente Vascular Cerebral/prevenção & controle , Varfarina/administração & dosagem , Administração Oral , Idoso , Idoso de 80 Anos ou mais , Anticoagulantes/efeitos adversos , Esquema de Medicação , Feminino , Alemanha/epidemiologia , Implante de Prótese de Valva Cardíaca/efeitos adversos , Humanos , Incidência , Masculino , Pessoa de Meia-Idade , Valva Mitral/diagnóstico por imagem , Valva Mitral/fisiopatologia , Insuficiência da Valva Mitral/diagnóstico por imagem , Insuficiência da Valva Mitral/epidemiologia , Insuficiência da Valva Mitral/fisiopatologia , Desenho de Prótese , Estudos Retrospectivos , Fatores de Risco , Índice de Gravidade de Doença , Acidente Vascular Cerebral/diagnóstico , Acidente Vascular Cerebral/epidemiologia , Fatores de Tempo , Resultado do Tratamento , Varfarina/efeitos adversos
17.
Clin Res Cardiol ; 109(5): 539-548, 2020 May.
Artigo em Inglês | MEDLINE | ID: mdl-31401672

RESUMO

AIMS: In the placebo-controlled, double-blind BOne marrOw transfer to enhance ST-elevation infarct regeneration (BOOST) 2 trial, intracoronary autologous bone marrow cell (BMC) transfer did not improve recovery of left ventricular ejection fraction (LVEF) at 6 months in patients with ST-elevation myocardial infarction (STEMI) and moderately reduced LVEF. Regional myocardial perfusion as determined by adenosine stress perfusion cardiac magnetic resonance imaging (S-CMR) may be more sensitive than global LVEF in detecting BMC treatment effects. Here, we sought to evaluate (i) the changes of myocardial perfusion in the infarct area over time (ii) the effects of BMC therapy on infarct perfusion, and (iii) the relation of infarct perfusion to LVEF recovery at 6 months. METHODS AND RESULTS: In 51 patients from BOOST-2 (placebo, n = 10; BMC, n = 41), S-CMR was performed 5.1 ± 2.9 days after PCI (before placebo/BMC treatment) and after 6 months. Infarct perfusion improved from baseline to 6 months in the overall patient cohort as reflected by the semi-quantitative parameters, perfusion defect-infarct size ratio (change from 0.54 ± 0.20 to 0.43 ± 0.22; P = 0.006) and perfusion defect-upslope ratio (0.54 ± 0.23 to 0.68 ± 0.22; P < 0.001), irrespective of randomised treatment. Perfusion defect-upslope ratio at baseline correlated with LVEF recovery (r = 0.62; P < 0.001) after 6 months, with a threshold of 0.54 providing the best sensitivity (79%) and specificity (74%) (area under the curve, 0.79; 95% confidence interval, 0.67-0.92). CONCLUSION: Infarct perfusion improves from baseline to 6 months and predicts LVEF recovery in STEMI patients undergoing early PCI. Intracoronary BMC therapy did not enhance infarct perfusion in the BOOST-2 trial.


Assuntos
Adenosina/administração & dosagem , Transplante de Medula Óssea , Imageamento por Ressonância Magnética , Infarto do Miocárdio com Supradesnível do Segmento ST/diagnóstico por imagem , Infarto do Miocárdio com Supradesnível do Segmento ST/terapia , Vasodilatadores/administração & dosagem , Idoso , Estudos de Coortes , Método Duplo-Cego , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Intervenção Coronária Percutânea , Infarto do Miocárdio com Supradesnível do Segmento ST/fisiopatologia , Sensibilidade e Especificidade , Volume Sistólico/fisiologia , Resultado do Tratamento , Remodelação Ventricular/fisiologia
18.
Arterioscler Thromb Vasc Biol ; 28(9): 1614-20, 2008 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-18511699

RESUMO

OBJECTIVE: The endogenous role of the VEGF family member vascular endothelial growth factor-B (VEGF-B) in pathological angiogenesis remains unclear. METHODS AND RESULTS: We studied the role of VEGF-B in various models of pathological angiogenesis using mice lacking VEGF-B (VEGF-B(-/-)) or overexpressing VEGF-B(167). After occlusion of the left coronary artery, VEGF-B deficiency impaired vessel growth in the ischemic myocardium whereas, in wild-type mice, VEGF-B(167) overexpression enhanced revascularization of the infarct and ischemic border zone. By contrast, VEGF-B deficiency did not affect vessel growth in the wounded skin, hypoxic lung, ischemic retina, or ischemic limb. Moreover, VEGF-B(167) overexpression failed to enhance vascular growth in the skin or ischemic limb. CONCLUSIONS: VEGF-B appears to have a relatively restricted angiogenic activity in the ischemic heart. These insights might offer novel therapeutic opportunities.


Assuntos
Vasos Coronários/metabolismo , Isquemia/metabolismo , Isquemia Miocárdica/metabolismo , Miocárdio/metabolismo , Neovascularização Fisiológica , Fator B de Crescimento do Endotélio Vascular/metabolismo , Indutores da Angiogênese/metabolismo , Animais , Vasos Coronários/efeitos dos fármacos , Vasos Coronários/fisiopatologia , Modelos Animais de Doenças , Técnicas de Transferência de Genes , Terapia Genética/métodos , Membro Posterior , Isquemia/patologia , Isquemia/fisiopatologia , Isquemia/terapia , Pulmão/irrigação sanguínea , Camundongos , Camundongos Endogâmicos C57BL , Camundongos Knockout , Camundongos Nus , Músculo Esquelético/irrigação sanguínea , Isquemia Miocárdica/patologia , Isquemia Miocárdica/fisiopatologia , Isquemia Miocárdica/terapia , Miocárdio/patologia , Neovascularização Fisiológica/efeitos dos fármacos , Proteínas Recombinantes/metabolismo , Vasos Retinianos/metabolismo , Pele/irrigação sanguínea , Regulação para Cima , Fator B de Crescimento do Endotélio Vascular/administração & dosagem , Fator B de Crescimento do Endotélio Vascular/deficiência , Fator B de Crescimento do Endotélio Vascular/genética , Receptor 1 de Fatores de Crescimento do Endotélio Vascular/metabolismo
19.
Circulation ; 115(4): 475-82, 2007 Jan 30.
Artigo em Inglês | MEDLINE | ID: mdl-17242279

RESUMO

BACKGROUND: The cell-associated proteoglycan syndecan-1 (Synd1) closely regulates inflammation and cell-matrix interactions during wound healing and tumorigenesis. The present study investigated whether Synd1 may also regulate cardiac inflammation, matrix remodeling, and function after myocardial infarction (MI). METHODS AND RESULTS: First, we showed increased protein and mRNA expression of Synd1 from 24 hours on, reaching its maximum at 7 days after MI and declining thereafter. Targeted deletion of Synd1 resulted in increased inflammation and accelerated, yet functionally adverse, infarct healing after MI. In concordance, adenoviral gene expression of Synd1 protected against exaggerated inflammation after MI, mainly by reducing transendothelial adhesion and migration of leukocytes, as shown in vitro. Increased inflammation in the absence of Synd1 resulted in increased monocyte chemoattractant protein-1 expression, increased activity of matrix metalloproteinase-2 and -9, and decreased activity of tissue transglutaminase, associated with increased collagen fragmentation and disorganization. Exaggerated inflammation and adverse matrix remodeling in the absence of Synd1 increased cardiac dilatation and impaired systolic function, whereas gene overexpression of Synd1 reduced inflammation and protected against cardiac dilatation and failure. CONCLUSIONS: Increased expression of Synd1 in the infarct protects against exaggerated inflammation and adverse infarct healing, thereby reducing cardiac dilatation and dysfunction after MI in mice.


Assuntos
Cardiomiopatia Dilatada/genética , Infarto do Miocárdio/genética , Sindecana-1/genética , Sindecana-1/fisiologia , Remodelação Ventricular/genética , Animais , Cardiomiopatia Dilatada/imunologia , Cardiomiopatia Dilatada/fisiopatologia , Colágeno/genética , Citocinas/genética , Citocinas/imunologia , Modelos Animais de Doenças , Feminino , Expressão Gênica , Coração/fisiologia , Leucócitos/imunologia , Masculino , Metaloproteinase 2 da Matriz/metabolismo , Metaloproteinase 9 da Matriz/metabolismo , Camundongos , Camundongos Endogâmicos BALB C , Camundongos Knockout , Mutagênese , Infarto do Miocárdio/imunologia , Infarto do Miocárdio/fisiopatologia , Miocárdio/enzimologia , Miocárdio/patologia , RNA Mensageiro/metabolismo , Sístole/genética , Remodelação Ventricular/imunologia
20.
Postepy Kardiol Interwencyjnej ; 14(3): 240-246, 2018.
Artigo em Inglês | MEDLINE | ID: mdl-30302099

RESUMO

Introduction: The implications of novel drug-eluting stent (DES) design modifications including ultra-thin struts and new concepts of polymer coating for procedural efficacy are still unknown. Aim: To evaluate procedural efficacy and short-term safety of a novel DES design. Material and methods: In this all-comers registry, 407 consecutive patients were enrolled upon undergoing percutaneous coronary interventions (PCI) with the thin-strut bioabsorbable abluminal polymer-coated SYNERGY stent. These patients were then compared with the previous 407 patients undergoing PCI performed by the same interventionalists using currently established second-generation DES (Promus Element plus, Xience prime, Resolute Integrity). Several clinical and procedural data were compared, and the coronary artery complexity was assessed by the American College of Cardiology/American Heart Association classification and SYNTAX Score. Results: The study population consisted of 814 patients. A total of 859 Synergy stents were deployed in 480 target vessels in the Synergy group (n = 407), and 904 stents in 469 vessels in the second-generation DES group (n = 407). Coincidentally, target lesions in the Synergy group (A 2.7%, B1 13.8%, B2 38.6%, C 45.0%) were more complex (p < 0.01) than those in the second-generation DES group (A 4.9%, B1 18.7%, B2 42.3%, C 34.2%). In cases with severe lesions (B2/C), the median contrast agent amount and fluoroscopy time were significantly lower in the Synergy group, indicating improved deliverability (110 ml vs. 150 ml; p < 0.01 and 7.2 min vs. 9.1 min; p = 0.01). Rates of in-hospital major adverse cardiovascular events were comparable between the two groups. Conclusions: In an all-comers, real-world PCI population, novel stent design modifications including ultra-thin struts and abluminal bioabsorbable polymer coating are associated with improved procedural performance.