Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 63
Filtrar
Mais filtros

País/Região como assunto
Tipo de documento
País de afiliação
Intervalo de ano de publicação
1.
Molecules ; 28(21)2023 Oct 24.
Artigo em Inglês | MEDLINE | ID: mdl-37959671

RESUMO

Several studies have explored the biological activities of Citrus aurantium flowers, fruits, and seeds, but the bioactivity of C. aurantium leaves, which are treated as waste, remains unclear. Thus, this study developed a pilot-scale ultrasonic-assisted extraction process using the Box-Behnken design (BBD) for the optimized extraction of active compounds from C. aurantium leaves, and their antityrosinase, antioxidant, antiaging, and antimicrobial activities were evaluated. Under optimal conditions in a 150× scaleup configuration (a 30 L ultrasonic machine) of a pilot plant, the total phenolic content was 69.09 mg gallic acid equivalent/g dry weight, which was slightly lower (3.17%) than the theoretical value. The half maximal inhibitory concentration of C. aurantium leaf extract (CALE) for 2,2-diphenyl-1-picrylhydrazyl-scavenging, 2,2'-azino-bis(3-ethylbenzothiazoline-6-sulfonic acid)-scavenging, antityrosinase, anticollagenase, antielastase and anti-matrix metalloprotein-1 activities were 123.5, 58.5, 181.3, 196.4, 216.3, and 326.4 mg/L, respectively. Moreover, the minimal inhibitory concentrations for bacteria and fungi were 150-350 and 500 mg/L, respectively. In total, 17 active compounds were detected in CALE-with linalool, linalyl acetate, limonene, and α-terpineol having the highest concentrations. Finally, the overall transdermal absorption and permeation efficiency of CALE was 95.9%. In conclusion, our CALE demonstrated potential whitening, antioxidant, antiaging, and antimicrobial activities; it was also nontoxic and easily absorbed into the skin as well as inexpensive to produce. Therefore, it has potential applications in various industries.


Assuntos
Anti-Infecciosos , Citrus , Antioxidantes/farmacologia , Ácido Gálico , Anti-Infecciosos/farmacologia , Extratos Vegetais/farmacologia
2.
Artigo em Inglês | MEDLINE | ID: mdl-38189371

RESUMO

Hexavalent chromium (Cr(VI)) is a global environmental pollutant. To reduce the risk caused by Cr(VI), a simple, accurate, reproducible, and inexpensive method for quantifying Cr(VI) in water and soil should be developed. In this study, three types of recombinant Escherichia coli biosensors (namely T7-lux-E. coli, T3-lux-E. coli, and SP6-lux-E. coli biosensor) containing promoters (T7, T3, and SP6), chromate-sensing regulator chrB, and the reporter gene luxAB were constructed. This study investigated the effects of cryogenic freezing temperature and time on trace Cr(VI) measurement by using recombinant E. coli biosensors. The results indicated that the activity of thawed frozen SP6-lux-E. coli cells stored at -20 °C for 270 days did not differ from that of freshly prepared cells. Turbidity and conductivity in water samples and organic matter in soil interfered with Cr(VI) measurement using the biosensor. The SP6-lux-E. coli biosensor exhibited a wide measurement range and a low deviation of <5% for measuring Cr(VI) in various Cr(VI)-contaminated water and soil samples and required only a simple pretreatment or extraction process even after 270-day storage at -20 °C. To the best of our knowledge, this is the first study to report the use of recombinant biosensors for accurately measuring Cr(VI) in both water and soil.


Assuntos
Técnicas Biossensoriais , Poluentes do Solo , Escherichia coli/genética , Cromo/análise , Poluentes do Solo/análise , Água , Solo
3.
Artigo em Inglês | MEDLINE | ID: mdl-31662034

RESUMO

Toluene is highly toxic and mutagenic, and it is generally used as an industrial solvent. Thus, toluene removal from air is necessary. To solve the problem of reducing high toluene concentrations with a short gas retention time (GRT), a quorum-sensing molecule [N-(3-oxododecanoyl)-L-homoserine lactone] (OHL) was added to a biotrickling filter (BTF). In this study, a BTF was used to treat synthetic and natural waste gases containing toluene. An extensive analysis was performed to understand the removal efficiency, removal characteristics, and bacterial community of the BTF. The addition of 20 µM OHL to the BTF significantly improved toluene removal, and more than 99.2% toluene removal was achieved at a GRT of 0.5 min when natural waste gas containing toluene (590-1020 ppm or 2.21-3.83 g m-3) was introduced. The maximum inlet load for toluene was 337.9 g m-3 h-1. Moreover, the BTF exhibited satisfactory adaptability to shock loading and shutdown operations. Pseudomonadaceae (33.0%) and Comamonadaceae (26.3%) were predominant bacteria in the system after a 98-day operation. These bacteria were responsible for toluene degradation. The optimal moisture content and low pressure drop for system operations demonstrated that the BTF was energy and cost efficient. Therefore, processing through a BTF with OHL is a favorable technique for toluene treatment.


Assuntos
Poluentes Atmosféricos/isolamento & purificação , Filtração/métodos , Microbiota , Percepção de Quorum , Tolueno/isolamento & purificação , 4-Butirolactona/análogos & derivados , 4-Butirolactona/metabolismo , Poluentes Atmosféricos/metabolismo , Bactérias/classificação , Bactérias/genética , Bactérias/isolamento & purificação , Bactérias/metabolismo , Biodegradação Ambiental , Reatores Biológicos/microbiologia , Filtração/instrumentação , Gases/isolamento & purificação , Gases/metabolismo , Homosserina/análogos & derivados , Homosserina/metabolismo , Microbiota/genética , Tolueno/metabolismo
4.
Sensors (Basel) ; 19(6)2019 Mar 22.
Artigo em Inglês | MEDLINE | ID: mdl-30909431

RESUMO

Chromium (VI) [Cr(VI)] compounds display high toxic, mutagenic, and carcinogenic potential. Biological analysis techniques (e.g., such as enzyme-based or cell-based sensors) have been developed to measure Cr(VI); however, these biological elements are sensitive to the environment, limited to measuring trace Cr(VI), and require deployment offsite. In this study, a three-stage single-chambered microbial fuel cell (SCMFC) biosensor inoculated with Exiguobacterium aestuarii YC211 was developed for in situ, real-time, and continuous Cr(VI) measurement. A negative linear relationship was observed between the Cr(VI) concentration (5⁻30 mg/L) and the voltage output using an SCMFC at 2-min liquid retention time. The theoretical Cr(VI) measurement range of the system could be extended to 5⁻90 mg/L by connecting three separate SCMFCs in series. The three-stage SCMFC biosensor could accurately measure Cr(VI) concentrations in actual tannery wastewater with low deviations (<7%). After treating the wastewater with the SCMFC, the original inoculated E. aestuarii remained dominant (>92.5%), according to the next-generation sequencing analysis. The stable bacterial community present in the SCMFC favored the reliable performance of the SCMFC biosensor. Thus, the three-stage SCMFC biosensor has potential as an early warning device with wide dynamic range for in situ, real-time, and continuous Cr(VI) measurement of tannery wastewater.


Assuntos
Bacillaceae/química , Fontes de Energia Bioelétrica/microbiologia , Técnicas Biossensoriais/métodos , Cromo/análise , Bacillaceae/metabolismo , Análise da Demanda Biológica de Oxigênio , Oxirredução , Águas Residuárias/análise
5.
Artigo em Inglês | MEDLINE | ID: mdl-29035671

RESUMO

This study was conducted to select electrogenic bacteria from wastewater sludge. Phylogenetic analysis revealed that Proteobacteria was the dominant phylum in the microbial fuel cell (MFC) during the decomposition process of organic pollutants. Five culturable bacteria strains - namely, Bacillus subtilis, Flavobacterium sp., Aeromonas hydrophila, Citrobacter freundii, and Stenotrophomonas sp. - have a double potential in dye removal and electricity generation. We inoculated the mixed electrogenic bacteria at a specific ratio and treated them with a triphenylmethane dye, Victoria blue R (VBR), to evaluate their electricity generation ability for the artificial and real wastewater. The results of the VBR shock-loading experiment indicated that the inoculated MFC could adapt to shock loading in 1-2 days and exhibited high removal efficiency (95-100%) for 100-800 mg L-1 VBR with a power density of 8.62 ± 0.10 to 34.81 ± 0.25 mW m-2. The selected electrogenic bacteria in the MFC could use VBR as only electron donor for power generation. The matrix effects of the real wastewater on VBR removal and electricity generation of MFC were insignificant. VBR degradation by the electrogenic bacteria involves a stepwise demethylation process to yield partially dealkylated VBR species. In addition, these results demonstrate the feasibility of inoculating culturable bacteria strains to develop an efficient MFC for purifying wastewater.


Assuntos
Bactérias/metabolismo , Fontes de Energia Bioelétrica/microbiologia , Corantes/metabolismo , Corantes de Rosanilina/metabolismo , Águas Residuárias/química , Poluentes Químicos da Água/metabolismo , Bactérias/química , Bactérias/classificação , Bactérias/isolamento & purificação , Biodegradação Ambiental , Eletricidade , Eletrodos , Filogenia , Esgotos/microbiologia , Eliminação de Resíduos Líquidos/métodos
6.
Artigo em Inglês | MEDLINE | ID: mdl-29465296

RESUMO

The effectiveness of an airlift reactor system in simultaneously removing hydrogen sulfide (H2S) and ammonia (NH3) from synthetic and actual waste gases was investigated. The effects of various parameters, including the ratio of inoculum dilution, the gas concentration, the gas retention time, catalyst addition, the bubble size, and light intensity, on H2S and NH3 removal were investigated. The results revealed that optimal gas removal could be achieved by employing an activated inoculum, using a small bubble stone, applying reinforced fluorescent light, adding Fe2O3 catalysts, and applying a gas retention time of 20 s. The shock loading did not substantially affect the removal efficiency of the airlift bioreactor. Moreover, more than 98.5% of H2S and 99.6% of NH3 were removed in treating actual waste gases. Fifteen bands or species were observed in a profile from denaturing gradient gel electrophoresis during waste gas treatment. Phylogenetic analysis revealed the phylum Proteobacteria to be predominant. Six bacterial strains were consistently present during the entire operating period; however, only Rhodobacter capsulatus, Rhodopseudomonas palustris, and Arthrobacter oxydans were relatively abundant in the system. The photosynthetic bacteria R. capsulatus and R. palustris were responsible for H2S oxidation, especially when the reinforced fluorescent light was used. The heterotrophic nitrifier A. oxydans was responsible for NH3 oxidation. To our knowledge, this is the first report on simultaneous H2S and NH3 removal using an airlift bioreactor system. It clearly demonstrates the effectiveness of the system in treating actual waste gases containing H2S and NH3.


Assuntos
Amônia/isolamento & purificação , Reatores Biológicos , Gases/química , Sulfeto de Hidrogênio/isolamento & purificação , Amônia/farmacocinética , Animais , Bactérias/classificação , Bactérias/crescimento & desenvolvimento , Reatores Biológicos/microbiologia , Indústria Alimentícia , Gases/farmacocinética , Sulfeto de Hidrogênio/farmacocinética , Esgotos/química , Esgotos/microbiologia , Suínos/microbiologia
7.
Sensors (Basel) ; 17(11)2017 Oct 27.
Artigo em Inglês | MEDLINE | ID: mdl-29076985

RESUMO

The extensive use of Cr(VI) in many industries and the disposal of Cr(VI)-containing wastes have resulted in Cr(VI)-induced environmental contamination. Cr(VI) compounds are associated with increased cancer risks; hence, the detection of toxic Cr(VI) compounds is crucial. Various methods have been developed for Cr(VI) measurement, but they are often conducted offsite and cannot provide real-time toxicity monitoring. A microbial fuel cell (MFC) is an eco-friendly and self-sustaining device that has great potential as a biosensor for in situ Cr(VI) measurement, especially for wastewater generated from different electroplating units. In this study, Exiguobacterium aestuarii YC211, a facultatively anaerobic, Cr(VI)-reducing, salt-tolerant, and exoelectrogenic bacterium, was isolated and inoculated into an MFC to evaluate its feasibility as a Cr(VI) biosensor. The Cr(VI) removal efficiency of E. aestuarii YC211 was not affected by the surrounding environment (pH 5-9, 20-35 °C, coexisting ions, and salinity of 0-15 g/L). The maximum power density of the MFC biosensor was 98.3 ± 1.5 mW/m² at 1500 Ω. A good linear relationship (r² = 0.997) was observed between the Cr(VI) concentration (2.5-60 mg/L) and the voltage output. The developed MFC biosensor is a simple device that can accurately measure Cr(VI) concentrations in the actual electroplating wastewater that is generated from different electroplating units within 30 min with low deviations (-6.1% to 2.2%). After treating the actual electroplating wastewater with the MFC, the predominant family in the biofilm was found to be Bacillaceae (95.3%) and was further identified as the originally inoculated E. aestuarii YC211 by next generation sequencing (NGS). Thus, the MFC biosensor can measure Cr(VI) concentrations in situ in the effluents from different electroplating units, and it can potentially help in preventing the violation of effluent regulations.

8.
Artigo em Inglês | MEDLINE | ID: mdl-28489972

RESUMO

A novel two-chamber microbial fuel cell (MFC) operation with a continuous anaerobic-aerobic decolorization system was developed to improve the degradation of the triphenylmethane dye, Victoria blue R (VBR). In addition, bioelectricity was generated during the VBR degradation process, and the operation parameters were optimized. The results indicated that the VBR removal efficiency and electricity generation were affected by the VBR concentration, liquid retention time (LRT), external resistance, gas retention time (GRT), and shock loading. The optimal operation parameters were as follows: VBR concentration, 600 mg L-1; LRT, 24 h; external resistance, 3300 Ω; and GRT, 60 s. Under these operating conditions, the VBR removal efficiency, COD removal efficiency, and power density were 98.2% ± 0.3%, 97.6% ± 0.5%, and 30.6 ± 0.4 mW m-2, respectively. According to our review of the relevant literature, this is the first paper to analyze the electrical characteristics of a continuous two-chamber MFC operation and demonstrate the feasibility of the simultaneous electricity generation and decolorization of VBR.


Assuntos
Fontes de Energia Bioelétrica , Técnicas Eletroquímicas/métodos , Corantes de Rosanilina/análise , Poluentes Químicos da Água/análise , Purificação da Água/métodos , Acinetobacter calcoaceticus/crescimento & desenvolvimento , Fontes de Energia Bioelétrica/microbiologia , Eletricidade , Eletrodos , Estudos de Viabilidade , Shewanella putrefaciens/crescimento & desenvolvimento , Águas Residuárias/química , Águas Residuárias/microbiologia
9.
Sensors (Basel) ; 16(8)2016 Aug 16.
Artigo em Inglês | MEDLINE | ID: mdl-27537887

RESUMO

Fast hexavalent chromium (Cr(VI)) determination is important for environmental risk and health-related considerations. We used a microbial fuel cell-based biosensor inoculated with a facultatively anaerobic, Cr(VI)-reducing, and exoelectrogenic Ochrobactrum anthropi YC152 to determine the Cr(VI) concentration in water. The results indicated that O. anthropi YC152 exhibited high adaptability to pH, temperature, salinity, and water quality under anaerobic conditions. The stable performance of the microbial fuel cell (MFC)-based biosensor indicated its potential as a reliable biosensor system. The MFC voltage decreased as the Cr(VI) concentration in the MFC increased. Two satisfactory linear relationships were observed between the Cr(VI) concentration and voltage output for various Cr(VI) concentration ranges (0.0125-0.3 mg/L and 0.3-5 mg/L). The MFC biosensor is a simple device that can accurately measure Cr(VI) concentrations in drinking water, groundwater, and electroplating wastewater in 45 min with low deviations (<10%). The use of the biosensor can help in preventing the violation of effluent regulations and the maximum allowable concentration of Cr(VI) in water. Thus, the developed MFC biosensor has potential as an early warning detection device for Cr(VI) determination even if O. anthropi YC152 is a possible opportunistic pathogen.


Assuntos
Fontes de Energia Bioelétrica/microbiologia , Técnicas Biossensoriais/métodos , Cromo/isolamento & purificação , Ochrobactrum anthropi/química , Anaerobiose , Cromo/toxicidade , Ochrobactrum anthropi/genética , Esgotos/química , Esgotos/microbiologia , Águas Residuárias/química , Purificação da Água/métodos
10.
Artigo em Inglês | MEDLINE | ID: mdl-26889692

RESUMO

Bioremediation is an environmentally friendly method of reducing heavy metal concentration and toxicity. A chromium-reducing bacterial strain, isolated from the vicinity of an electroplate factory, was identified as Ochrobactrum sp. YC211. The efficiency and capacity per time of Ochrobactrum sp. YC211 for hexavalent chromium (Cr(VI)) removal under anaerobic conditions were superior to those under aerobic conditions. An acceptable removal efficiency (96.5 ± 0.6%) corresponding to 30.2 ± 0.8 mg-Cr (g-dry cell weight-h)(-1) was achieved by Ochrobactrum sp. YC211 at 300 mg L(-1) Cr(VI). A temperature of 30°C and pH 7 were the optimal parameters for Cr(VI) removal. By examining reactivated cells, permeabilized cells, and cell-free extract, we determined that Cr(VI) removal by Ochrobactrum sp. YC211 under anaerobic conditions mainly occurred in the soluble fraction of the cell and can be regarded as an enzymatic reaction. The results also indicated that an Ochrobactrum sp. YC211 microbial fuel cell (MFC) with an anaerobic anode was considerably superior to that with an aerobic anode in bioelectricity generation and Cr(VI) removal. The maximum power density and Cr(VI) removal efficiency of the MFC were 445 ± 3.2 mW m(-2) and 97.2 ± 0.3%, respectively. Additionally, the effects of coexisting ions (Cu(2+), Zn(2+), Ni(2+), SO4(2-), and Cl(-)) in the anolyte on the MFC performance and Cr(VI) removal were nonsignificant (P > 0.05). To our knowledge, this is the first report to compare Cr(VI) removal by different cells and MFC types under aerobic and anaerobic conditions.


Assuntos
Bactérias Anaeróbias/metabolismo , Biodegradação Ambiental , Carcinógenos Ambientais/metabolismo , Cromo/metabolismo , Galvanoplastia , Metais Pesados/metabolismo , Ochrobactrum/metabolismo , Resíduos Industriais/análise , Esgotos/análise , Esgotos/química , Poluentes do Solo/análise , Poluentes do Solo/metabolismo , Taiwan
11.
Sensors (Basel) ; 16(1)2015 Dec 28.
Artigo em Inglês | MEDLINE | ID: mdl-26729113

RESUMO

The conventional Biochemical Oxygen Demand (BOD) method takes five days to analyze samples. A microbial fuel cell (MFC) may be an alternate tool for rapid BOD determination in water. However, a MFC biosensor for continuous BOD measurements of water samples is still unavailable. In this study, a MFC biosensor inoculated with known mixed cultures was used to determine the BOD concentration. Effects of important parameters on establishing a calibration curve between the BOD concentration and output signal from the MFC were evaluated. The results indicate monosaccharides were good fuel, and methionine, phenylalanine, and ethanol were poor fuels for electricity generation by the MFC. Ions in the influent did not significantly affect the MFC performance. CN(-) in the influent could alleviate the effect of antagonistic electron acceptors on the MFC performance. The regression equation for BOD concentration and current density of the biosensor was y = 0.0145x + 0.3317. It was adopted to measure accurately and continuously the BOD concentration in actual water samples at an acceptable error margin. These results clearly show the developed MFC biosensor has great potential as an alternative BOD sensing device for online measurements of wastewater BOD.


Assuntos
Fontes de Energia Bioelétrica/microbiologia , Análise da Demanda Biológica de Oxigênio/instrumentação , Técnicas Biossensoriais/instrumentação , Águas Residuárias/química , Águas Residuárias/microbiologia , Glucose/metabolismo , Ácido Glutâmico/metabolismo
12.
Environ Technol ; 36(9-12): 1141-6, 2015.
Artigo em Inglês | MEDLINE | ID: mdl-25362971

RESUMO

Chitosan is a potential substitute for traditional aluminium salts in water treatment systems. This study compared the characteristics of humic acid (HA) removal by using acid-soluble chitosan, water-soluble chitosan, and coagulant mixtures of chitosan with aluminium sulphate (alum) or polyaluminium chloride (PACl). In addition, we evaluated their respective coagulation efficiencies at various coagulant concentrations, pH values, turbidities, and hardness levels. Furthermore, we determined the size and settling velocity of flocs formed by these coagulants to identify the major factors affecting HA coagulation. The coagulation efficiency of acid- and water-soluble chitosan for 15 mg/l of HA was 74.4% and 87.5%, respectively. The optimal coagulation range of water-soluble chitosan (9-20 mg/l) was broader than that of acid-soluble chitosan (4-8 mg/l). Notably, acid-soluble chitosan/PACl and water-soluble chitosan/alum coagulant mixtures exhibited a higher coagulation efficiency for HA than for PACl or alum alone. Furthermore, these coagulant mixtures yielded an acceptable floc settling velocity and savings in both installation and operational expenses. Based on these results, we confidently assert that coagulant mixtures with a 1:1 mass ratio of acid-soluble chitosan/PACl and water-soluble chitosan/alum provide a substantially more cost-effective alternative to using chitosan alone for removing HA from water.


Assuntos
Quitosana/química , Substâncias Húmicas , Purificação da Água , Compostos de Alúmen , Hidróxido de Alumínio
13.
Environ Technol ; 35(17-20): 2204-11, 2014.
Artigo em Inglês | MEDLINE | ID: mdl-25145173

RESUMO

Microbial fuel cells (MFCs) have attracted considerable attention as potential biosensors. A MFC biosensor for rapid measurement of biochemical oxygen demand (BOD) has been recently studied. However, a standardized bacterial mixture inoculated in the MFC biosensor for BOD measurement is unavailable. Thus, the commercial application of a MFC biosensor is limited. In this study, a mediator-less MFC biosensor inoculated with known mixed cultures to quickly determine BOD concentration was tested. Optimal external resistance, operating temperature and measurement time for the MFC biosensor were determined to be 5000 omega, 35 degrees C and 12h, respectively. A good relationship between BOD concentration and voltage output, high reproducibility and long-term stability for the MFC biosensor was observed. The newly developed MFC biosensor was inoculated with a mixture of six bacterial strains (Thermincola carboxydiphila, Pseudomonas aeruginosa, Ochrobactrum intermedium, Shewanella frigidimarina, Citrobacter freundii and Clostridium acetobutylicum) capable of degrading complex organic compounds and surviving toxic conditions. The described MFC biosensor was able to successfully measure BOD concentrations below 240 mg L(-1) in real wastewater samples.


Assuntos
Análise da Demanda Biológica de Oxigênio/métodos , Técnicas Biossensoriais/métodos , Águas Residuárias/química , Fontes de Energia Bioelétrica , Oxigênio/análise , Oxigênio/metabolismo , Temperatura
14.
Environ Technol ; 35(1-4): 286-93, 2014.
Artigo em Inglês | MEDLINE | ID: mdl-24600867

RESUMO

Microbial fuel cells (MFCs) can, besides running on wastewater, also derive energy directly from certain aquatic plants. However, few studies have focussed on electricity generation using aerobic anodes. This study presents a comparison of the MFC performances of an anaerobic-anode MFC (ana-MFC) and an aerobic-anode MFC (aa-MFC), and shows their individual conditions for optimal operation. Results show that the maximum power density of 7.07 +/- 0.45 mW/m2 for the ana-MFC occurred at 500 omega, whereas the aa-MFC had a maximum power density of 2.34 +/- 0.16 mW/m2 at 2200 omega. The ana-MFC generally achieved high electricity generation, and the aa-MFC achieved relatively high electricity generation when fed with a diluted substrate. In the ana-MFC, the optimal substrate for electricity generation was glucose (fermentable substrate); however, glucose and acetic acid (non-fermentable substrate) were both suitable substrates for the aa-MFC. The optimal gas retention times of the ana-MFC and the aa-MFC were 9 and 120 s, respectively. This retention time is an important limiting factor of electricity generation for the ana-MFC. The aa-MFCs fed with different substrates exhibited non-significant differences between bacterial communities. We observed the relative diversities of bacterial communities in the ana-MFC fed with various substrates. The results of denaturing gradient gel electrophoresis analysis suggest that Ochrobactrum intermedium, Delftia acidovorans, and Citrobacterfreundii may be potential electrogenic bacteria. To our knowledge, this is the first study comparing the MFC performances of anaerobic and aerobic anodes.


Assuntos
Fenômenos Fisiológicos Bacterianos , Fontes de Energia Bioelétrica/microbiologia , Eletrodos/microbiologia , Transferência de Energia , Desenho de Equipamento , Análise de Falha de Equipamento
15.
Environ Technol ; 34(1-4): 283-8, 2013.
Artigo em Inglês | MEDLINE | ID: mdl-23530342

RESUMO

Chitosan is a potential substitute for traditional aluminium salts in water treatment systems. This research compared the coagulant performance of acid-soluble chitosan with water-soluble chitosan and with coagulant mixtures of chitosan and aluminium sulfate (alum). We also assessed the coagulant performance of chitosan and poly-aluminium chloride (PAC) to remove kaolinite from turbid water. In addition, we evaluated their respective coagulation efficiencies under different coagulant concentrations, degrees of turbidity (NTU) and pH levels. Furthermore, we determined the size and settling velocity of flocs formed by these coagulants in order to illustrate major factors affecting kaolinite coagulation. The optimal concentrations of acid- versus water- soluble chitosan required to remove kaolinite from a 300 NTU suspension were 4.0 and 10.0 mg/l, respectively-with individual efficiencies of 79.3 and 92.4%, in that order. Optimum concentrations ofwater-soluble chitosan demonstrated a broader range than that of acid-soluble chitosan. In addition, it is of note that chitosan/alum and chitosan/PAC water-soluble coagulant mixtures demonstrated much wider ranges of optimal concentrations for turbidity reduction than either alum or PAC alone. Moreover, our water-soluble chitosan coagulant mixtures produced denser floc with elevated settling velocities that favour cost savings relevant to both installation and operational expenses. Based on our observations of these noteworthy performances, we confidently propose that a coagulant mixture with a 1:1 mass ratio of chitosan and alum presents a remarkably more cost-effective alternative to the use of chitosan alone in water treatment systems.


Assuntos
Compostos de Alúmen/química , Quitosana/química , Caulim/química , Purificação da Água/métodos , Concentração de Íons de Hidrogênio
16.
Environ Technol ; 34(1-4): 313-20, 2013.
Artigo em Inglês | MEDLINE | ID: mdl-23530345

RESUMO

The use of matured compost as an inoculation agent to improve the composting of vegetable and fruit wastes in a laboratory-scale composter was evaluated, and the commercial feasibility of this approach in a pilot-scale (1.8 x 10(4) L) composter was subsequently confirmed. The effect of aeration rate on the physico-chemical and biological properties of compost was also studied. Aeration rate affected the fermentation temperature, moisture content, pH, O2 consumption rate, CO2 production rate and the formation of odour. The optimal aeration rate was 2.5 L air/kg dry solid/min. The CO2 production rate approached the theoretical value during composting and was linearly dependent on temperature, indicating that the compost system had good operating characteristics. The inoculation of cellulolytic bacteria and deodorizing bacteria to compost in the pilot-scale composter led to an 18.2% volatile solids loss and a 64.3% volume reduction ratio in 52 h; only 1.5 ppm(v) odour was detected. This is the first study to focus on both operating performance and odour removal in a pilot-scale composter.


Assuntos
Resíduos de Alimentos , Odorantes , Microbiologia do Solo , Solo/análise , Ar , Carbono/análise , Dióxido de Carbono/análise , Estudos de Viabilidade , Frutas , Concentração de Íons de Hidrogênio , Nitratos/análise , Nitrogênio/análise , Consumo de Oxigênio , Temperatura , Verduras , Água/análise
17.
Heliyon ; 8(9): e10498, 2022 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-36097484

RESUMO

The physiological activity of the 50% ethanolic extract of Citrus aurantium flower before and after fermentation was investigated in this study. C. aurantium flowers grown in Taiwan were extracted using 100% methanol or 50% ethanol and then fermented by one of six microbes: four species of lactic acid bacteria (Bifidobacterium bifidum, Bifidobacterium lactis, Lactobacillus acidophilus, and Lactobacillus brevis) anaerobically cultivated in MRS broth and two species of mold (Aspergillus oryzae and Aspergillus niger) aerobically cultivated in potato dextrose broth. The 50% ethanolic extract of C. aurantium flowers exhibited higher tyrosinase inhibition (IC50: 200.8 ± 11.6 mg/L) and antioxidative activity than did a 100% methanolic extract (IC50: 274.1 ± 15.7 mg/L). The 50% ethanolic extract fermented by L. brevis (L. brevis-fermented extract) exhibited the highest yield (86.2% ± 1.2%) and physiological activity. The L. brevis-fermented extract exhibited over 5.2-, 13.5-, 12.5-, 3.17-, and 4.29-fold higher antityrosinase activity, antioxidative activity, antibacterial activity, total flavonoid content, and antiwrinkle activity than did the unfermented extract. The L. brevis-fermented extract can be considered safe because it exerted no toxic effect on CCD-966SK or HEMn cells at concentrations of 400 and 200 mg/L, respectively. The fermented extract (40 mg/L) inhibited melanin formation, reducing it to 50.8% ± 2.3%. Furthermore, the L. brevis-fermented extract exhibited excellent antiaging and antiwrinkle activity, as determined from MMP-1, MMP-2, elastase, and collagenase activity. The improvement in physiological characteristics, especially the considerable formation of neohesperidin, is mainly attributable to biosynthesis or biotransformation by L. brevis during fermentation. In conclusion, the 50% ethanolic extract of C. aurantium flowers fermented with L. brevis can be used in cosmetics applications aiming for skin-whitening or antiwrinkle properties.

18.
Molecules ; 16(10): 8504-14, 2011 Oct 11.
Artigo em Inglês | MEDLINE | ID: mdl-21989311

RESUMO

The antibacterial activity of water-soluble chitosan derivatives prepared by Maillard reactions against Staphylococcus aureus, Listeria monocytogenes, Bacillus cereus, Escherichia coli, Shigella dysenteriae, and Salmonella typhimurium was examined. Relatively high antibacterial activity against various microorganisms was noted for the chitosan-glucosamine derivative as compared to the acid-soluble chitosan. In addition, it was found that the susceptibility of the test organisms to the water-soluble chitosan derivative was higher in deionized water than in saline solution. Metal ions were also found to reduce the antibacterial activity of the water-soluble chitosan derivative on S. aureus. The marked increase in glucose level, protein content and lactate dehydrogenase (LDH) activity was observed in the cell supernatant of S. aureus exposed to the water-soluble chitosan derivative in deionized water. The results suggest that the water-soluble chitosan produced by Maillard reaction may be a promising commercial substitute for acid-soluble chitosan.


Assuntos
Antibacterianos/farmacologia , Bactérias/efeitos dos fármacos , Quitosana/análogos & derivados , Reação de Maillard , Antibacterianos/química , Bacillus cereus/efeitos dos fármacos , Membrana Celular/efeitos dos fármacos , Quitosana/metabolismo , Quitosana/farmacologia , Contagem de Colônia Microbiana , DNA/efeitos dos fármacos , DNA/metabolismo , Escherichia coli/efeitos dos fármacos , L-Lactato Desidrogenase/metabolismo , Listeria monocytogenes/efeitos dos fármacos , Testes de Sensibilidade Microbiana , Inibidores da Síntese de Ácido Nucleico/farmacologia , Inibidores da Síntese de Proteínas/farmacologia , RNA Mensageiro/genética , RNA Mensageiro/metabolismo , Salmonella typhimurium/efeitos dos fármacos , Shigella dysenteriae/efeitos dos fármacos , Staphylococcus aureus/efeitos dos fármacos
19.
Artigo em Inglês | MEDLINE | ID: mdl-22175871

RESUMO

Average emission levels as high as 800 ppm(v) NH(3) have often been found during the anaerobic fermentation process. At these levels, NH(3) is regarded as an environmental toxic compound. High concentrations of NH(3) gas are difficult to treat in a single treatment process, suggesting that, in terms of economic cost and treatment performance, a coupled system may be a feasible technological alternative. In the coupled TiO(2) photocatalytic-biological treatment system evaluated here, the optimal gas retention time for NH(3) removal--in terms of removal efficiency and capital cost--was 26 s. High gas temperatures, high NH(3) concentrations, and low oxygen contents were unfavorable conditions for NH(3) removal by the photoreactor. The coupled system successfully removed concentrated NH(3) gas (R % > 97 %) under disrupted and shutdown conditions. The photoreactor component of the system successfully fulfilled its role as a pretreatment process and enhanced the performance of the biotrickling filter at a high inlet NH(3) load (2,277 g-N m(-3) day(-1)). Potential ammonia-oxidizing bacteria, including Bacillus cereus, Pseudomonas aeruginosa, and Stenotrophomonas sp., were isolated under the high inlet NH(3) load condition. These microbial strains have a potential as biological agents in the removal of high concentrations of NH(3) in waste gas or wastewater.


Assuntos
Poluentes Atmosféricos/metabolismo , Poluentes Atmosféricos/efeitos da radiação , Amônia/metabolismo , Amônia/efeitos da radiação , Bactérias/metabolismo , Raios Ultravioleta , Poluição do Ar/prevenção & controle , Bactérias/classificação , Bactérias/isolamento & purificação , Carga Bacteriana , Biodegradação Ambiental , Catálise , Processos Fotoquímicos , Titânio/química
20.
Biosensors (Basel) ; 11(10)2021 Sep 27.
Artigo em Inglês | MEDLINE | ID: mdl-34677313

RESUMO

In this study, we constructed a recombinant Escherichia coli strain with different promoters inserted between the chromate-sensing regulator chrB and the reporter gene luxAB to sense low hexavalent chromium (Cr(VI)) concentrations (<0.05 mg/L); subsequently, its biosensor characteristics (sensitivity, selectivity, and specificity) for measuring Cr(VI) in various water bodies were evaluated. The luminescence intensity of each biosensor depended on pH, temperature, detection time, coexisting carbon source, coexisting ion, Cr(VI) oxyanion form, Cr(VI) concentration, cell type, and type of medium. Recombinant lux-expressing E. coli with the T7 promoter (T7-lux-E. coli, limit of detection (LOD) = 0.0005 mg/L) had the highest luminescence intensity or was the most sensitive for Cr(VI) detection, followed by E. coli with the T3 promoter (T3-lux-E. coli, LOD = 0.001 mg/L) and that with the SP6 promoter (SP6-lux-E. coli, LOD = 0.005 mg/L). All biosensors could be used to determine whether the Cr(VI) standard was met in terms of water quality, even when using thawing frozen cells as biosensors after 90-day cryogenic storage. The SP6-lux-E. coli biosensor had the shortest detection time (0.5 h) and the highest adaptability to environmental interference. The T7-lux-E. coli biosensor-with the optimal LOD, a wide measurement range (0.0005-0.5 mg/L), and low deviation (-5.0-7.9%) in detecting Cr(VI) from industrial effluents, domestic effluents, and surface water-is an efficient Cr(VI) biosensor. This unprecedented study is to evaluate recombinant lux E. coli with dissimilar promoters for their possible practice in Cr(VI) measurement in water bodies, and the biosensor performance is clearly superior to that of past systems in terms of detection time, LOD, and detection deviation for real water samples.


Assuntos
Técnicas Biossensoriais , Cromo/análise , Monitoramento Ambiental , Poluentes Químicos da Água/análise , Bioensaio , Escherichia coli , Limite de Detecção , Medições Luminescentes , Água
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA