Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 1 de 1
Filtrar
Mais filtros

Base de dados
Ano de publicação
Tipo de documento
País de afiliação
Intervalo de ano de publicação
1.
Echocardiography ; 30(5): 588-98, 2013 May.
Artigo em Inglês | MEDLINE | ID: mdl-23252706

RESUMO

BACKGROUND: Various left ventricular (LV) vortex parameters obtained during contrast echocardiography (CE) have been recently described. The aim of this study was to investigate their determinants and associations with conventional hemodynamic variables. METHODS: CE was performed and LV pressure was simultaneously measured during pharmacologic inotropic modulation in 8 mongrel dogs. Customized software was used to assess both vortex geometric parameters (vortex depth [VD], length [VL], width [VW], transverse position, and sphericity index [SI]) and pulsatility parameters (relative strength [RS], vortex relative strength [VRS], and vortex pulsation correlation [VPC]). The associations between each of these parameters and conventional indices representing LV systolic and diastolic function were analyzed. RESULTS: VD and VW did not change significantly during pharmacologic modulation, whereas VL (P = 0.0034) and SI (P = 0.001) showed significant and progressive linear decreases from baseline during dobutamine infusion. Significant linear changes during positive and negative inotropic modulation were observed in all pulsatiliy parameters (P < 0.01 each). Geometric parameters were critically dependent on LV volume, with pulsatility parameters showing significant positive correlations with heart rate, systolic and diastolic blood pressure (DBP), dp/dtmax , early and late mitral inflow velocities, and peak systolic and diastolic annular velocities. In multivariate analysis, LV end-diastolic volume was a main determinant for VL (r = 0.29, P < 0.001) and VW (r = 0.65, P < 0.001), whereas dp/dtmax for pulsatility parameters (RS [r = 0.61, P < 0.001], VRS [r = 0.46, P < 0.001] and VPC [r = 0.62, P < 0.001]). CONCLUSION: Geometric and pulsatility parameters differed in their association with LV geometry and conventional physiologic indices representing LV function. These differences should be considered in interpreting these variables.


Assuntos
Dobutamina/farmacologia , Ecocardiografia/métodos , Função Ventricular Esquerda/efeitos dos fármacos , Função Ventricular Esquerda/fisiologia , Animais , Velocidade do Fluxo Sanguíneo , Cães , Feminino , Frequência Cardíaca/efeitos dos fármacos , Interpretação de Imagem Assistida por Computador , Masculino , Modelos Animais , Contração Miocárdica/efeitos dos fármacos , Contração Miocárdica/fisiologia , Variações Dependentes do Observador , Fluxo Pulsátil/fisiologia
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA