Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Mais filtros

Base de dados
Ano de publicação
Tipo de documento
País de afiliação
Intervalo de ano de publicação
1.
Phys Eng Sci Med ; 45(4): 1029-1041, 2022 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-36063348

RESUMO

Knowledge-based planning (KBP) can increase plan quality, consistency and efficiency. In this study, we assess the success of a using a publicly available KBP model compared with developing an in-house model for prostate cancer radiotherapy using a single, commercially available treatment planning system based on the ability of the model to achieve the centre's planning goals. Two radiation oncology centres each created a prostate cancer KBP model using the Eclipse RapidPlan software. These two models and a third publicly-available, shared model were tested at three centres in a retrospective planning study. The publicly-available model achieved lower rectum doses than the other two models. However, the planning-target-volume (PTV) doses did not meet the local planning goals and the model could not be adjusted to correct this. As a result, the plans most likely to satisfy local planning goals and requirements were created using an in-house model. For centres without an existing in-house model, a model created by another centre with similar planning goals was found to be preferred. Variations in local planning practices including contouring, treatment technique and planning goals can influence the relative performance of KBP. The value of publicly available KBP models could be enhanced through standardisation of planning goals and contouring guidelines, providing information related to the planning goals used to create the model and increased flexibility to allow local adaptation of the KBP model.


Assuntos
Neoplasias da Próstata , Radioterapia de Intensidade Modulada , Masculino , Humanos , Planejamento da Radioterapia Assistida por Computador/métodos , Radioterapia de Intensidade Modulada/métodos , Dosagem Radioterapêutica , Estudos Retrospectivos , Próstata , Neoplasias da Próstata/diagnóstico por imagem , Neoplasias da Próstata/radioterapia
2.
Phys Med Biol ; 55(3): 783-97, 2010 Feb 07.
Artigo em Inglês | MEDLINE | ID: mdl-20071763

RESUMO

Backscatter factors are important parameters in the determination of dose for kilovoltage x-ray beams. However, backscatter factors are difficult to measure experimentally, and tabulated values are based largely on Monte Carlo calculations. In this study we have determined new backscatter factors by both experimental and Monte Carlo methods, and compared them with existing backscatter factors published in the AAPM TG-61 protocol. The purpose of this study is twofold: (1) to evaluate the overall effectiveness of using Gafchromic EBT film for backscatter factor measurements and (2) to determine whether existing Monte Carlo-calculated backscatter factors need to be updated. We measured backscatter factors using Gafchromic EBT film for three field sizes (2, 4 and 6 cm diameter cones) and three kilovoltage beam qualities, including 280 kVp for which similar measurements have not previously been reported. We also present new Monte Carlo-calculated backscatter factors obtained using the EGSnrc/BEAMnrc code system to simulate the Pantak kilovoltage x-ray unit used in our measurements. The results were compared with backscatter factors tabulated in the AAPM TG-61 protocol for kilovoltage x-ray dosimetry. The largest difference between our measured and calculated backscatter factors and the AAPM TG-61 values was found to be 2.5%. This agreement is remarkably good, considering that the AAPM TG-61 values consist of a combination of experimental and Monte Carlo calculations obtained over 20 years ago using different measurement techniques, as well as older Monte Carlo code and cross-section data. Furthermore, our Monte Carlo-calculated backscatter factors agree within 1% with the AAPM TG-61 values for all beam qualities and field sizes. Our Gafchromic film measurements had slightly larger differences with the AAPM TG-61 backscatter factors, up to approximately 2% for the 6 cm diameter cone at a beam quality of 50 kVp. The largest difference in backscatter factors, of 2.5%, was found between Monte Carlo-calculated and Gafchromic film-measured data for the 100 kVp x-ray beam with the 4 cm diameter cone. The differences in backscatter factors between the three data sets (measurements, calculations and published values) are all within the uncertainties from our Gafchromic film measurements and Monte Carlo calculations. Our results demonstrate the suitability of using Gafchromic EBT film to measure equipment-specific backscatter factors for kilovoltage x-ray beams over the entire energy range and also confirm that backscatter factors published in kilovoltage dosimetry protocols still remain valid.


Assuntos
Simulação por Computador , Dosimetria Fotográfica/métodos , Método de Monte Carlo , Radiometria/métodos , Espalhamento de Radiação , Raios X , Dosimetria Fotográfica/instrumentação , Imagens de Fantasmas , Guias de Prática Clínica como Assunto , Doses de Radiação , Radiometria/instrumentação , Software , Incerteza , Água
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA