Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Mais filtros

Base de dados
Ano de publicação
Tipo de documento
País de afiliação
Intervalo de ano de publicação
1.
Respiration ; 90(6): 507-11, 2015.
Artigo em Inglês | MEDLINE | ID: mdl-26390141

RESUMO

A 61-year-old patient with alcohol use disorder (AUD) was referred for suspicion of sleep apnea syndrome (SAS). He had incurred three road accidents attributed to sleepiness over the previous year, shortly after initiation of high-dose (100 mg b.i.d.) treatment with baclofen, a molecule increasingly used in the management of AUD. Polysomnography revealed a severe central SAS (CSAS) with an apnea-hypopnea index (AHI) of 81.6/h. Baclofen was suggested as a possible cause of the CSAS, and after its withdrawal, a second polysomnography was done, showing the disappearance of the central apneas and a shift to severe obstructive SAS (AHI 43.9/h), for which a positive airway pressure (CPAP) treatment was initiated. A third polysomnography was performed under CPAP after reintroduction of baclofen (50 mg b.i.d.) by the patient, showing reappearance of the CSAS (AHI 42.1/h). This case report illustrates the deleterious effect of baclofen on breathing physiology during sleep. Since it is typically prescribed off label at high doses to a population of patients potentially using other substances that inhibit the ventilatory drive, this possible adverse effect is a major concern. When considering the use of baclofen in patients with AUD, the potential for sleep-disordered breathing should be weighed and carefully monitored.


Assuntos
Alcoolismo/tratamento farmacológico , Baclofeno/efeitos adversos , Agonistas dos Receptores de GABA-B/efeitos adversos , Apneia do Sono Tipo Central/induzido quimicamente , Pressão Positiva Contínua nas Vias Aéreas , Humanos , Masculino , Pessoa de Meia-Idade , Polissonografia , Apneia do Sono Tipo Central/diagnóstico
2.
Respir Med ; 107(12): 2053-60, 2013 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-24169072

RESUMO

INTRODUCTION: Respiratory events occurring under non-invasive ventilation (NIV) may produce sleep fragmentation. Alternatives to polysomnography (PSG) should be validated for providing simple monitoring tools for patients treated at home with NIV. OBJECTIVES: To study the value of pulse wave amplitude (PWA) reduction as a surrogate marker of cortical micro-arousals associated with respiratory events occurring during NIV. METHODS: 27 PSG tracings under NIV recorded in 9 stable patients with Obesity Hypoventilation Syndrome (OHS), under 3 different ventilator modes (no back-up rate, low or high back-up rate) were analyzed. For all respiratory events (obstructive, central, or mixed event), the association with EEG-micro-arousals, PWA reduction of more than 30% and the presence of associated SpO2 desaturation ≥ 4% was recorded. RESULTS: 2474 respiratory events during NREM sleep were analyzed. 73.6% were associated with an EEG-MA, 91.4% with a ≥ 4% decrease in SpO2, and 74.9% with a significant PWA reduction. Sensitivity of PWA for the detection of an EEG-micro-arousal related to a respiratory event was 89.1% [95%CI: 76.7-95.3]. Positive predictive value (PPV) was 87.0% [95%CI: 75.0-94.0]. Sensitivity of PWA was highest in the S mode, compared to both other S/T modes, p = <0.001. Sensitivity of PWA was also higher for central and mixed events, compared to obstructive respiratory events, p = <0.05. CONCLUSIONS: PWA reduction is a sensitive marker with a high PPV for the detection of EEG-MA associated with respiratory events during NREM sleep in stable OHS patients treated by NIV. In this situation, PWA could be used to improve scoring of hypopneas and allow an appropriate assessment of sleep fragmentation related to respiratory events.


Assuntos
Nível de Alerta/fisiologia , Ventilação não Invasiva , Síndrome de Hipoventilação por Obesidade/fisiopatologia , Sono/fisiologia , Eletroencefalografia , Humanos , Pessoa de Meia-Idade , Síndrome de Hipoventilação por Obesidade/terapia , Polissonografia , Análise de Onda de Pulso
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA