RESUMO
Left atrial appendage occlusion devices (LAAO) are a feasible alternative for non-valvular atrial fibrillation (AF) patients at high risk of thromboembolic stroke and contraindication to antithrombotic therapies. However, optimal LAAO device configurations (i.e., size, type, location) remain unstandardized due to the large anatomical variability of the left atrial appendage (LAA) morphology, leading to a 4-6% incidence of device-related thrombus (DRT). In-silico simulations have the potential to assess DRT risk and identify the key factors, such as suboptimal device positioning. This work presents fluid simulation results computed on 20 patient-specific left atrial geometries, analysing different commercially available LAAO occluders, including plug-type and pacifier-type devices. In addition, we explored two distinct device positions: 1) the real post-LAAO intervention configuration derived from follow-up imaging; and 2) one covering the pulmonary ridge if it was not achieved during the implantation (13 out of 20). In total, 33 different configurations were analysed. In-silico indices indicating high risk of DRT (e.g., low blood flow velocities and flow complexity around the device) were combined with particle deposition analysis based on a discrete phase model. The obtained results revealed that covering the pulmonary ridge with the LAAO device may be one of the key factors to prevent DRT, resulting in higher velocities and reduced flow recirculations (e.g., mean velocities of 0.183 ± 0.12 m/s and 0.236 ± 0.16 m/s for uncovered versus covered positions in DRT patients). Moreover, disk-based devices exhibited enhanced adaptability to various LAA morphologies and, generally, demonstrated a lower risk of abnormal events after LAAO implantation.
Assuntos
Apêndice Atrial , Fibrilação Atrial , Simulação por Computador , Hemodinâmica , Modelos Cardiovasculares , Trombose , Humanos , Trombose/fisiopatologia , Fibrilação Atrial/fisiopatologia , Hemodinâmica/fisiologia , Apêndice Atrial/fisiopatologia , Átrios do Coração/fisiopatologia , Dispositivo para Oclusão Septal , Biologia ComputacionalRESUMO
BACKGROUND AND AIMS: Patients with repaired tetralogy of Fallot remain at risk of life-threatening ventricular tachycardia related to slow-conducting anatomical isthmuses (SCAIs). Preventive ablation of SCAI identified by invasive electroanatomical mapping is increasingly performed. This study aimed to non-invasively identify SCAI using 3D late gadolinium enhancement cardiac magnetic resonance (3D-LGE-CMR). METHODS: Consecutive tetralogy of Fallot patients who underwent right ventricular electroanatomical mapping (RV-EAM) and 3D-LGE-CMR were included. High signal intensity threshold for abnormal myocardium was determined based on direct comparison of bipolar voltages and signal intensity by co-registration of RV-EAM with 3D-LGE-CMR. The diagnostic performance of 3D-LGE-CMR to non-invasively identify SCAI was determined, validated in a second cohort, and compared with the discriminative ability of proposed risk scores. RESULTS: The derivation cohort consisted of 48 (34 ± 16 years) and the validation cohort of 53 patients (36 ± 18 years). In the derivation cohort, 78 of 107 anatomical isthmuses (AIs) identified by EAM were normal-conducting AI, 22 were SCAI, and 7 blocked AI. High signal intensity threshold was 42% of the maximal signal intensity. The sensitivity and specificity of 3D-LGE-CMR for identifying SCAI or blocked AI were 100% and 90%, respectively. In the validation cohort, 85 of 124 AIs were normal-conducting AI, 36 were SCAI, and 3 blocked AI. The sensitivity and specificity of 3D-LGE-CMR were 95% and 91%, respectively. All risk scores showed an at best modest performance to identify SCAI (area under the curve ≤ .68). CONCLUSIONS: 3D late gadolinium enhancement cardiac magnetic resonance can identify SCAI with excellent accuracy and may refine non-invasive risk stratification and patient selection for invasive EAM in tetralogy of Fallot.
Assuntos
Imageamento Tridimensional , Taquicardia Ventricular , Tetralogia de Fallot , Humanos , Tetralogia de Fallot/cirurgia , Tetralogia de Fallot/diagnóstico por imagem , Masculino , Feminino , Adulto , Taquicardia Ventricular/diagnóstico , Taquicardia Ventricular/diagnóstico por imagem , Adulto Jovem , Meios de Contraste , Pessoa de Meia-IdadeRESUMO
PURPOSE: Wideband phase-sensitive inversion recovery (PSIR) late gadolinium enhancement (LGE) enables myocardial scar imaging in implantable cardioverter defibrillators (ICD) patients, mitigating hyperintensity artifacts. To address subendocardial scar visibility challenges, a 2D breath-hold single-shot electrocardiography-triggered black-blood (BB) LGE sequence was integrated with wideband imaging, enhancing scar-blood contrast. METHODS: Wideband BB, with increased bandwidth in the inversion pulse (0.8-3.8 kHz) and T2 preparation refocusing pulses (1.6-5.0 kHz), was compared with conventional and wideband PSIR, and conventional BB, in a phantom and sheep with and without ICD, and in six patients with cardiac devices and known myocardial injury. ICD artifact extent was quantified in the phantom and specific absorption rate (SAR) was reported for each sequence. Image contrast ratios were analyzed in both phantom and animal experiments. Expert radiologists assessed image quality, artifact severity, and scar segments in patients and sheep. Additionally, histology was performed on the sheep's heart. RESULTS: In the phantom, wideband BB reduced ICD artifacts by 62% compared to conventional BB while substantially improving scar-blood contrast, but with a SAR more than 24 times that of wideband PSIR. Similarly, the animal study demonstrated a considerable increase in scar-blood contrast with wideband BB, with superior scar detection compared with wideband PSIR, the latter confirmed by histology. In alignment with the animal study, wideband BB successfully eliminated severe ICD hyperintensity artifacts in all patients, surpassing wideband PSIR in image quality and scar detection. CONCLUSION: Wideband BB may play a crucial role in imaging ICD patients, offering images with reduced ICD artifacts and enhanced scar detection.
Assuntos
Artefatos , Cicatriz , Meios de Contraste , Desfibriladores Implantáveis , Gadolínio , Miocárdio , Imagens de Fantasmas , Cicatriz/diagnóstico por imagem , Humanos , Animais , Ovinos , Gadolínio/química , Meios de Contraste/química , Masculino , Miocárdio/patologia , Imageamento por Ressonância Magnética , Feminino , Pessoa de Meia-Idade , Idoso , Processamento de Imagem Assistida por Computador/métodos , Coração/diagnóstico por imagem , Eletrocardiografia , Aumento da Imagem/métodosRESUMO
INTRODUCTION: Bicuspid aortic valves (BAV) are the most common congenital heart defects and the extent of ventricular arrhythmias (VA) in patients with BAV is unclear. The objective of this study is to describe VAs and late gadolinium enhancement cardiac magnetic resonance imaging (LGE-CMR) in patients with BAV. METHODS: A total of 19 patients with BAV (18 males, age: 58 ± 13 years) were referred for VA ablation procedures. Ten patients had BAVs at the time of ablation, nine patients had prior aortic valve replacement for a BAV. All but one patient had LGE-CMR and all patients underwent programmed ventricular stimulation at the time of the ablation. RESULTS: Frequent PVCs were the targeted VAs in 17/19 patients and VT in 2/19 patients. Monomorphic ventricular tachycardia (VT) was inducible in 6 patients. A total of 15 VTs were inducible (2.5 ± 1.0 VTs per patient with a mean cycle length of 322 ± 83 msec). LGE was present in 13 patients. Patients with inducible VT had larger borderzone and core scar compared to non-inducible patients (7.8 ± 2.1 cm3 vs. 2.5 ± 3.1 cm3 and 5.1 ± 2.6 cm3 vs. 1.9 ± 3.0 cm3, p-value < .05 for both). PVCs and VTs were mapped to the periaortic valve area in 12 patients and 4 patients, respectively. The PVC burden was reduced from 27 ± 13 to 3 ± 6 (p < .001) and the ejection fraction improved from 49 ± 13% to 55 ± 9% (p = .005). CONCLUSIONS: VAs in patients with BAV often originate from the perivalvular area and patients often have LGE and inducible VT. LGE may be due to ventricular remodeling secondary to the presence of BAV and harbors the arrhythmogenic substrate for VT.
Assuntos
Doença da Válvula Aórtica Bicúspide , Taquicardia Ventricular , Humanos , Masculino , Feminino , Pessoa de Meia-Idade , Doença da Válvula Aórtica Bicúspide/cirurgia , Doença da Válvula Aórtica Bicúspide/fisiopatologia , Doença da Válvula Aórtica Bicúspide/complicações , Doença da Válvula Aórtica Bicúspide/diagnóstico por imagem , Taquicardia Ventricular/fisiopatologia , Taquicardia Ventricular/diagnóstico , Taquicardia Ventricular/etiologia , Idoso , Adulto , Valva Aórtica/cirurgia , Valva Aórtica/anormalidades , Valva Aórtica/diagnóstico por imagem , Valva Aórtica/fisiopatologia , Ablação por Cateter , Potenciais de Ação , Doenças das Valvas Cardíacas/fisiopatologia , Doenças das Valvas Cardíacas/diagnóstico por imagem , Doenças das Valvas Cardíacas/complicações , Doenças das Valvas Cardíacas/cirurgia , Frequência Cardíaca , Resultado do Tratamento , Fatores de Risco , Valor Preditivo dos Testes , Estudos Retrospectivos , Técnicas Eletrofisiológicas Cardíacas , Meios de Contraste/administração & dosagem , Imagem Cinética por Ressonância MagnéticaRESUMO
INTRODUCTION: Scar substrate in nonischemic cardiomyopathy (NICM) patients is often difficult to identify. Advances in cardiac imaging, especially using late iodine-enhanced computed tomography (LIE-CT), allow better characterization of scars giving rise to ventricular tachycardia (VT). Currently, there are limited data on clinical correlates of CT-derived scar substrates in NICM. We sought assess the relationship between scar location on LIE-CT and outcomes after radiofrequency catheter ablation (RFCA) in NICM patients with VT. METHODS: From 2020 to 2022, consecutive patients with NICM undergoing VT RFCA with integration of cardiac CT scar modeling (inHeart, Pessac, France) were included at two US tertiary care centers. The CT protocol included both arterial-enhanced imaging for anatomical modeling and LIE-CT for scar assessment. The distribution of substrate on CT was analyzed in relation to patient outcomes, with primary endpoints being VT recurrence and the need for repeat ablation procedure. RESULTS: Sixty patients were included (age 64 ± 12 years, 90% men). Over a median follow-up of 120 days (interquartile range [IQR]: 41-365), repeat ablation procedures were required in 32 (53%). VT recurrence occurred in 46 (77%), with a median time to recurrence of 40 days (IQR: 8-65). CT-derived total scar volume positively correlated with intrinsic QRS duration (r = .34, p = 0.008). Septal scar was found on CT in 34 (57%), and lateral scar in 40 (7%). On univariate logistic regression, septal scar was associated with increased odds of repeat ablation (odds ratio [OR]: 2.9 [1.0-8.4]; p = 0.046), while lateral scar was not (OR: 0.9 [0.3-2.7]; p = 0.855). Septal scar better predicted VT recurrence when compared to lateral scar, but neither were statistically significant (septal scar OR: 3.0 [0.9-10.7]; p = 0.078; lateral scar OR: 1.7 [0.5-5.9]; p = 0.391). CONCLUSION: In this tertiary care referral population, patients with NICM undergoing VT catheter ablation with septal LIE-CT have nearly threefold increased risk of need for repeat ablation.
RESUMO
BACKGROUND: Myocardial T1-rho (T1ρ) mapping is a promising method for identifying and quantifying myocardial injuries without contrast agents, but its clinical use is hindered by the lack of dedicated analysis tools. PURPOSE: To explore the feasibility of clinically integrated artificial intelligence-driven analysis for efficient and automated myocardial T1ρ mapping. STUDY TYPE: Retrospective. POPULATION: Five hundred seventy-three patients divided into a training (N = 500) and a test set (N = 73) including ischemic and nonischemic cases. FIELD STRENGTH/SEQUENCE: Single-shot bSSFP T1ρ mapping sequence at 1.5 T. ASSESSMENT: The automated process included: left ventricular (LV) wall segmentation, right ventricular insertion point detection and creation of a 16-segment model for segmental T1ρ value analysis. Two radiologists (20 and 7 years of MRI experience) provided ground truth annotations. Interobserver variability and segmentation quality were assessed using the Dice coefficient with manual segmentation as reference standard. Global and segmental T1ρ values were compared. Processing times were measured. STATISTICAL TESTS: Intraclass correlation coefficients (ICCs) and Bland-Altman analysis (bias ±2SD); Paired Student's t-tests and one-way ANOVA. A P value <0.05 was considered significant. RESULTS: The automated approach significantly reduced processing time (3 seconds vs. 1 minute 51 seconds ± 22 seconds). In the test set, automated LV wall segmentation closely matched manual results (Dice 81.9% ± 9.0) and closely aligned with interobserver segmentation (Dice 82.2% ± 6.5). Excellent ICCs were achieved on a patient basis (0.94 [95% CI: 0.91 to 0.96]) with bias of -0.93 cm2 ± 6.60. There was no significant difference in global T1ρ values between manual (54.9 msec ± 4.6; 95% CI: 53.8 to 56.0 msec, range: 46.6-70.9 msec) and automated processing (55.4 msec ± 5.1; 95% CI: 54.2 to 56.6 msec; range: 46.4-75.1 msec; P = 0.099). The pipeline demonstrated a high level of agreement with manual-derived T1ρ values at the patient level (ICC = 0.85; bias +0.52 msec ± 5.18). No significant differences in myocardial T1ρ values were found between methods across the 16 segments (P = 0.75). DATA CONCLUSION: Automated myocardial T1ρ mapping shows promise for the rapid and noninvasive assessment of heart disease. EVIDENCE LEVEL: 3 TECHNICAL EFFICACY: Stage 1.
RESUMO
AIMS: Using thermal-based energy sources [radiofrequency (RF) energy/cryo energy] for catheter ablation is considered effective and safe when performing pulmonary vein isolation (PVI) in patients with paroxysmal atrial fibrillation (AF). However, treatment success remains limited and complications can occur due to the propagation of thermal energy into non-target tissues. We aim to compare pulsed field ablation (PFA) with RF ablation in terms of efficacy and safety for patients with drug-resistant paroxysmal AF. METHODS AND RESULTS: The BEAT PAROX-AF trial is a European multicentre, superiority, open-label randomized clinical trial in two parallel groups. A total of 292 participants were recruited in 9 high-volume European clinical centres in 5 countries. Patients with paroxysmal AF were randomized to PFA (FARAPULSE Endocardial Ablation System©, Boston Scientific) or RF using the CLOSE protocol with contact force sensing catheter (SmartTouch© catheter and CARTO© Biosense Webster). The primary endpoint will be the 1-year recurrence of atrial arrhythmia, and the major secondary safety endpoint will be the occurrence of acute (<7 days) procedure-related serious adverse events, or pulmonary vein stenosis, or atrio-oesophageal fistula up to 12 months. Additionally, five sub-studies investigate the effect of PFA on oesophageal safety, cerebral lesions, cardiac autonomic nervous system, durability of PVI as assessed during redo ablation procedures, and atrial and ventricular function. The study began on 27 December 2021 and concluded recruitment on 17 January 2024. Results will be available in mid-2025. CONCLUSION: The BEAT PAROX-AF trial aims to provide critical insights into the optimal treatment approach for patients with paroxysmal AF.
Assuntos
Fibrilação Atrial , Ablação por Cateter , Humanos , Fibrilação Atrial/cirurgia , Fibrilação Atrial/fisiopatologia , Fibrilação Atrial/diagnóstico , Fibrilação Atrial/terapia , Ablação por Cateter/métodos , Resultado do Tratamento , Veias Pulmonares/cirurgia , Feminino , Masculino , Recidiva , Europa (Continente) , Pessoa de Meia-IdadeRESUMO
Cardiovascular magnetic resonance imaging (MRI) in patients with cardiac implants, such as pacemakers and defibrillators, has gained importance in recent years with the development of modern cardiac implantable electronic devices. The increasing clinical need to perform MRI examinations in patients with cardiac implants has driven the development of new advanced MRI sequences to mitigate image artifacts associated with cardiac implants. More specifically, advances in imaging techniques, such as wideband late gadolinium enhancement imaging, wideband T1 mapping, and wideband perfusion, have been designed to improve image quality and examinations in patients with cardiac implants, enabling a comprehensive and more reliable diagnosis, which was previously unattainable in these patients. This review article explores recent developments and applications of wideband techniques in the field of cardiovascular MRI, offering insights into their transformative potential. Clinical applications of wideband cardiovascular MRI are highlighted, particularly in assessing myocardial viability, guiding ventricular tachycardia ablation, and characterizing myocardial tissue.
Assuntos
Desfibriladores Implantáveis , Marca-Passo Artificial , Humanos , Imageamento por Ressonância Magnética/métodos , Imagem Cinética por Ressonância Magnética/métodos , Aumento da Imagem/métodosRESUMO
Background At follow-up CT after left atrial appendage occlusion (LAAO), hypoattenuation thickening (HAT) on the atrial aspect of the device is a common finding but the clinical implications require further study. Purpose To assess the association of HAT grade at follow-up CT with clinical characteristics and outcomes in patients who underwent LAAO. Materials and Methods This prospective study included consecutive participants with atrial fibrillation and who were at high risk for stroke (CHA2DS2-VASc score ≥4) who underwent LAAO and were administered pacifier or nonpacifier devices at two French medical centers between January 2012 and November 2020. Postprocedure CT images were evaluated by two radiologists in consensus and device-specific interpretation algorithms were applied to classify HAT as low grade (low suspicion of thrombosis) or high grade (high suspicion of thrombosis). The association between HAT grade and clinical characteristics was assessed using multinomial logistic regression, and variables associated with risk of stroke were assessed using a Cox proportional hazard model. Results This study included 412 participants (mean age, 76 years ± 8 [SD]; 284 male participants) who underwent follow-up CT at a mean of 4.2 months ± 1.7 after LAAO. Low-grade and high-grade HAT were depicted in 98 of 412 (23.8%) and 21 of 412 (5.1%) participants, respectively. High-grade HAT was associated with higher odds of antithrombotic drug discontinuation during follow-up (odds ratio, 9.5; 95% CI: 3.1, 29.1; P < .001), whereas low-grade HAT was associated with lower odds of persisting left atrial appendage patency (odds ratio, 0.46; 95% CI: 0.27, 0.79; P = .005). During a median follow-up of 17 months (IQR, 11-41 months), stroke occurred in 24 of 412 (5.8%) participants. High-grade HAT was associated with stroke (hazard ratio, 4.6; 95% CI: 1.5, 14.0; P = .008) and low-grade HAT (P = .62) was not. Conclusion Low-grade HAT was a more common finding at CT performed after LAAO CT (24%) than was high-grade HAT (5%), but it was associated with more favorable outcomes than high-grade HAT, which was associated with higher stroke risk. © RSNA, 2023 Supplemental material is available for this article. See also the editorial by Choe in this issue.
Assuntos
Apêndice Atrial , Acidente Vascular Cerebral , Humanos , Masculino , Idoso , Apêndice Atrial/diagnóstico por imagem , Apêndice Atrial/cirurgia , Estudos Prospectivos , Acidente Vascular Cerebral/diagnóstico por imagem , Acidente Vascular Cerebral/etiologia , Átrios do Coração , Tomografia Computadorizada por Raios XRESUMO
INTRODUCTION: Variants of cardiomyopathy genes in patients with nonischemic cardiomyopathy (NICM) generate various phenotypes of cardiac scar and delayed enhancement cardiac magnetic resonance (DE-CMR) imaging which may impact ventricular tachycardia (VT) management. METHODS: The objective was to compare the findings of cardiomyopathy genetic testing on DE-CMR imaging and long-term outcomes among patients with NICM undergoing VT ablation procedures. Image phenotyping and genotyping were performed in a consecutive series of patients referred for VT ablation and correlated to survival free of VT. Scar depth index (SDI) (% of scar at 0-3 mm, 3-5 mm and >5 mm projected on the closest endocardial surface) was determined. RESULTS: Forty-three patients were included (11 women, 55 ± 14 years, ejection fraction (EF) 45 ± 16%) and were followed for 3.4 ± 2.9 years. Pathogenic variants (PV) were identified in 16 patients (37%) in the following genes: LMNA (n = 5), TTN (n = 5), DSP (n = 2), AMLS1 (n = 1), MYBPC3 (n = 1), PLN (n = 1), and SCN5A (n = 1). A ring-like septal scar (RLSS) pattern was more often seen in patients with pathogenic variants (66% vs 15%, p = .001). RLSS was associated with deeper seated scars (SDI >5 mm 30.6 ± 22.6% vs 12.4 ± 16.2%, p = .005), and increased VT recurrence (HR 5.7 95% CI[1.8-18.4], p = .003). After adjustment for age, sex, EF, and total scar burden, the presence of a PV remained independently associated with worse outcomes (HR 4.7 95% CI[1.22-18.0], p = .02). CONCLUSIONS: Preprocedural genotyping and scar phenotyping is beneficial to identify patients with a favorable procedural outcome. Some PVs are associated with an intramural, deeper seated scar phenotype and have an increase of VT recurrence after ablation.
Assuntos
Cardiomiopatias , Ablação por Cateter , Taquicardia Ventricular , Humanos , Feminino , Cicatriz/diagnóstico , Cicatriz/genética , Cicatriz/patologia , Genótipo , Cardiomiopatias/diagnóstico por imagem , Cardiomiopatias/genética , Cardiomiopatias/patologia , Taquicardia Ventricular/diagnóstico , Taquicardia Ventricular/genética , Taquicardia Ventricular/cirurgia , Ventrículos do Coração , Ablação por Cateter/efeitos adversos , Ablação por Cateter/métodosRESUMO
BACKGROUND: The impact of filtering on bipolar electrograms (EGMs) has not been systematically examined. We tried to clarify the optimal filter configuration for ventricular tachycardia (VT) ablation. METHODS: Fifteen patients with VT were included. Eight different filter configurations were prospectively created for the distal bipoles of the ablation catheter: 1.0-250, 10-250, 100-250, 30-50, 30-100, 30-250, 30-500, and 30-1000 Hz. Pre-ablation stable EGMs with good contact (contact force > 10 g) were analyzed. Baseline fluctuation, baseline noise, bipolar peak-to-peak voltage, and presence of local abnormal ventricular activity (LAVA) were compared between different filter configurations. RESULTS: In total, 2276 EGMs with multiple bipolar configurations in 246 sites in scar and border areas were analyzed. Baseline fluctuation was only observed in the high-pass filter of (HPF) ≤ 10 Hz (p < .001). Noise level was lowest at 30-50 Hz (0.018 [0.012-0.029] mV), increased as the low-pass filter (LPF) extended, and was highest at 30-1000 Hz (0.047 [0.041-0.061] mV) (p < .001). Conversely, the HPF did not affect the noise level at ≤30 Hz. As the HPF extended to 100 Hz, bipolar voltages significantly decreased (p < .001), but were not affected when the LPF was extended to ≥100 Hz. LAVAs were most frequently detected at 30-250 Hz (207/246; 84.2%) and 30-500 Hz (208/246; 84.6%), followed by 30-1000 Hz (205/246; 83.3%), but frequently missed at LPF ≤ 100 Hz or HPF ≤ 10 Hz (p < .001). A 50-Hz notch-filter reduced the bipolar voltage by 43.9% and LAVA-detection by 34.5% (p < .0001). CONCLUSION: Bipolar EGMs are strongly affected by filter settings in scar/border areas. In all, 30-250 or 30-500 Hz may be the best configuration, minimizing the baseline fluctuation, baseline noise, and detecting LAVAs. Not applying the 50-Hz notch filter may be beneficial to avoid missing VT substrate.
Assuntos
Ablação por Cateter , Taquicardia Ventricular , Humanos , Taquicardia Ventricular/diagnóstico , Taquicardia Ventricular/cirurgia , Cicatriz , Ablação por Cateter/efeitos adversosRESUMO
AIM: Ventricular arrhythmias (VAs) are the most common cause of death in patients with repaired Tetralogy of Fallot (rTOF). However, risk stratifying remains challenging. We examined outcomes following programmed ventricular stimulation (PVS) with or without subsequent ablation in patients with rTOF planned for pulmonary valve replacement (PVR). METHODS: We included all consecutive patients with rTOF referred to our institution from 2010 to 2018 aged ≥18 years for PVR. Right ventricular (RV) voltage maps were acquired and PVS was performed from two different sites at baseline, and if non-inducible under isoproterenol. Catheter and/or surgical ablation was performed when patients were inducible or when slow conduction was present in anatomical isthmuses (AIs). Postablation PVS was undertaken to guide implantable cardioverter-defibrillator (ICD) implantation. RESULTS: Seventy-seven patients (36.2 ± 14.3 years old, 71% male) were included. Eighteen were inducible. In 28 patients (17 inducible, 11 non-inducible but with slow conduction) ablation was performed. Five had catheter ablation, surgical cryoablation in 9, both techniques in 14. ICDs were implanted in five patients. During a follow-up of 74 ± 40 months, no sudden cardiac death occurred. Three patients experienced sustained VAs, all were inducible during the initial EP study. Two of them had an ICD (low ejection fraction for one and important risk factor for arrhythmia for the second). No VAs were reported in the non-inducible group (p < .001). CONCLUSION: Preoperative EPS can help identifying patients with rTOF at risk for VAs, providing an opportunity for targeted ablation and may improve decision-making regarding ICD implantation.
Assuntos
Implante de Prótese de Valva Cardíaca , Valva Pulmonar , Taquicardia Ventricular , Tetralogia de Fallot , Humanos , Masculino , Adolescente , Adulto , Adulto Jovem , Pessoa de Meia-Idade , Feminino , Tetralogia de Fallot/diagnóstico por imagem , Tetralogia de Fallot/cirurgia , Tetralogia de Fallot/complicações , Valva Pulmonar/diagnóstico por imagem , Valva Pulmonar/cirurgia , Implante de Prótese de Valva Cardíaca/efeitos adversos , Resultado do Tratamento , Taquicardia Ventricular/diagnóstico , Taquicardia Ventricular/etiologia , Taquicardia Ventricular/cirurgiaRESUMO
The potential of cardiac magnetic resonance to improve cardiovascular care and patient management is considerable. Myocardial T1-rho (T1ρ) mapping, in particular, has emerged as a promising biomarker for quantifying myocardial injuries without exogenous contrast agents. Its potential as a contrast-agent-free ("needle-free") and cost-effective diagnostic marker promises high impact both in terms of clinical outcomes and patient comfort. However, myocardial T1ρ mapping is still at a nascent stage of development and the evidence supporting its diagnostic performance and clinical effectiveness is scant, though likely to change with technological improvements. The present review aims at providing a primer on the essentials of myocardial T1ρ mapping, and to describe the current range of clinical applications of the technique to detect and quantify myocardial injuries. We also delineate the important limitations and challenges for clinical deployment, including the urgent need for standardization, the evaluation of bias, and the critical importance of clinical testing. We conclude by outlining technical developments to be expected in the future. If needle-free myocardial T1ρ mapping is shown to improve patient diagnosis and prognosis, and can be effectively integrated in cardiovascular practice, it will fulfill its potential as an essential component of a cardiac magnetic resonance examination.
Assuntos
Infarto do Miocárdio , Humanos , Infarto do Miocárdio/patologia , Valor Preditivo dos Testes , Miocárdio/patologia , Imageamento por Ressonância Magnética/métodos , Meios de Contraste , Espectroscopia de Ressonância MagnéticaRESUMO
AIMS: Although the mechanism of an atrial tachycardia (AT) can usually be elucidated using modern high-resolution mapping systems, it would be helpful if the AT mechanism and circuit could be predicted before initiating mapping. OBJECTIVE: We examined if the information gathered from the cycle length (CL) of the tachycardia can help predict the AT-mechanism and its localization. METHODS: One hundred and thirty-eight activation maps of ATs including eight focal-ATs, 94 macroreentrant-ATs, and 36 localized-ATs in 95 patients were retrospectively reviewed. Maximal CL (MCL) and minimal CL (mCL) over a minute period were measured via a decapolar catheter in the coronary sinus. CL-variation and beat-by-beat CL-alternation were examined. Additionally, the CL-respiration correlation was analysed by the RhythmiaTM system. : Both MCL and mCL were significantly shorter in macroreentrant-ATs [MCL = 288 (253-348) ms, P = 0.0001; mCL = 283 (243-341) ms, P = 0.0012], and also shorter in localized-ATs [MCL = 314 (261-349) ms, P = 0.0016; mCL = 295 (248-340) ms, P = 0.0047] compared to focal-ATs [MCL = 506 (421-555) ms, mCL = 427 (347-508) ms]. An absolute CL-variation (MCL-mCL) < 24â ms significantly differentiated re-entrant ATs from focal-ATs with a sensitivity = 96.9%, specificity = 100%, positive predictive value (PPV) = 100%, and negative predictive value (NPV) = 66.7%. The beat-by-beat CL-alternation was observed in 10/138 (7.2%), all of which showed the re-entrant mechanism, meaning that beat-by-beat CL-alternation was the strong sign of re-entrant mechanism (PPV = 100%). Although the CL-respiration correlation was observed in 28/138 (20.3%) of ATs, this was predominantly in right-atrium (RA)-ATs (24/41, 85.7%), rather than left atrium (LA)-ATs (4/97, 4.1%). A positive CL-respiration correlation highly predicted RA-ATs (PPV = 85.7%), and negative CL-respiration correlation probably suggested LA-ATs (NPV = 84.5%). CONCLUSION: Detailed analysis of the tachycardia CL helps predict the AT-mechanism and the active AT chamber before an initial mapping.
Assuntos
Ablação por Cateter , Taquicardia Supraventricular , Humanos , Estudos Retrospectivos , Técnicas Eletrofisiológicas Cardíacas , Taquicardia , Átrios do Coração , Resultado do TratamentoRESUMO
AIMS: Assess prevalence, risk factors, and management of patients with intra-cardiac thrombus referred for scar-related ventricular tachycardia (VT) ablation. METHODS AND RESULTS: Consecutive VT ablation referrals between January 2015 and December 2019 were reviewed (n = 618). Patients referred for de novo, scar-related VT ablation who underwent pre-procedure cardiac computed tomography (cCT) were included. We included 401 patients [61 ± 14 years; 364 male; left ventricular ejection fraction (LVEF) 40 ± 13%]; 45 patients (11%) had cardiac thrombi on cCT at 49 sites [29 LV; eight left atrial appendage (LAA); eight right ventricle (RV); four right atrial appendage]. Nine patients had pulmonary emboli. Overall predictors of cardiac thrombus included LV aneurysm [odds ratio (OR): 6.6, 95%, confidence interval (CI): 3.1-14.3], LVEF < 40% (OR: 3.3, CI: 1.5-7.3), altered RV ejection fraction (OR: 2.3, CI: 1.1-4.6), and electrical storm (OR: 2.9, CI: 1.4-6.1). Thrombus location-specific analysis identified LV aneurysm (OR: 10.9, CI: 4.3-27.7) and LVEF < 40% (OR: 9.6, CI: 2.6-35.8) as predictors of LV thrombus and arrhythmogenic right ventricular cardiomyopathy (OR: 10.6, CI: 1.2-98.4) as a predictor for RV thrombus. Left atrial appendage thrombi exclusively occurred in patients with atrial fibrillation. Ventricular tachycardia ablation was finally performed in 363 including 7 (16%) patients with thrombus but refractory electrical storm. These seven patients had tailored ablation with no embolic complications. Only one (0.3%) ablation-related embolic event occurred in the entire cohort. CONCLUSION: Cardiac thrombus can be identified in 11% of patients referred for scar-related VT ablation. These findings underscore the importance of systematic thrombus screening to minimize embolic risk.
Assuntos
Ablação por Cateter , Cardiopatias , Taquicardia Ventricular , Trombose , Humanos , Masculino , Taquicardia Ventricular/epidemiologia , Taquicardia Ventricular/cirurgia , Taquicardia Ventricular/diagnóstico , Volume Sistólico , Prevalência , Cicatriz , Função Ventricular Esquerda , Cardiopatias/diagnóstico por imagem , Cardiopatias/epidemiologia , Cardiopatias/complicações , Trombose/diagnóstico por imagem , Trombose/epidemiologia , Ablação por Cateter/efeitos adversos , Fatores de Risco , Resultado do TratamentoRESUMO
OBJECTIVE: To simplify black-blood late gadolinium enhancement (BL-LGE) cardiac imaging in clinical practice using an image-based algorithm for automated inversion time (TI) selection. MATERIALS AND METHODS: The algorithm selects from BL-LGE TI scout images, the TI corresponding to the image with the highest number of sub-threshold pixels within a region of interest (ROI) encompassing the blood-pool and myocardium. The threshold value corresponds to the most recurrent pixel intensity of all scout images within the ROI. ROI dimensions were optimized in 40 patients' scans. The algorithm was validated retrospectively (80 patients) versus two experts and tested prospectively (5 patients) on a 1.5 T clinical scanner. RESULTS: Automated TI selection took ~ 40 ms per dataset (manual: ~ 17 s). Fleiss' kappa coefficient for automated-manual, intra-observer and inter-observer agreements were [Formula: see text]= 0.73, [Formula: see text] = 0.70 and [Formula: see text] = 0.63, respectively. The agreement between the algorithm and any expert was better than the agreement between the two experts or between two selections of one expert. DISCUSSION: Thanks to its good performance and simplicity of implementation, the proposed algorithm is a good candidate for automated BL-LGE imaging in clinical practice.
Assuntos
Meios de Contraste , Gadolínio , Humanos , Estudos Retrospectivos , Coração/diagnóstico por imagem , Miocárdio , Imageamento por Ressonância Magnética/métodosRESUMO
PURPOSE OF REVIEW: Imaging plays a crucial role in the therapy of ventricular tachycardia (VT). We offer an overview of the different methods and provide information on their use in a clinical setting. RECENT FINDINGS: The use of imaging in VT has progressed recently. Intracardiac echography facilitates catheter navigation and the targeting of moving intracardiac structures. Integration of pre-procedural CT or MRI allows for targeting the VT substrate, with major expected impact on VT ablation efficacy and efficiency. Advances in computational modeling may further enhance the performance of imaging, giving access to pre-operative simulation of VT. These advances in non-invasive diagnosis are increasingly being coupled with non-invasive approaches for therapy delivery. This review highlights the latest research on the use of imaging in VT procedures. Image-based strategies are progressively shifting from using images as an adjunct tool to electrophysiological techniques, to an integration of imaging as a central element of the treatment strategy.
Assuntos
Ablação por Cateter , Taquicardia Ventricular , Humanos , Taquicardia Ventricular/diagnóstico por imagem , Taquicardia Ventricular/cirurgia , Arritmias Cardíacas , Coração , Frequência Cardíaca , Ablação por Cateter/métodos , Resultado do TratamentoRESUMO
AIMS: Mapping data of human ventricular fibrillation (VF) are limited. We performed detailed mapping of the activities underlying the onset of VF and targeted ablation in patients with structural cardiac abnormalities. METHODS AND RESULTS: We evaluated 54 patients (50 ± 16 years) with VF in the setting of ischaemic (n = 15), hypertrophic (n = 8) or dilated cardiomyopathy (n = 12), or Brugada syndrome (n = 19). Ventricular fibrillation was mapped using body-surface mapping to identify driver (reentrant and focal) areas and invasive Purkinje mapping. Purkinje drivers were defined as Purkinje activities faster than the local ventricular rate. Structural substrate was delineated by electrogram criteria and by imaging. Catheter ablation was performed in 41 patients with recurrent VF. Sixty-one episodes of spontaneous (n = 10) or induced (n = 51) VF were mapped. Ventricular fibrillation was organized for the initial 5.0 ± 3.4â s, exhibiting large wavefronts with similar cycle lengths (CLs) across both ventricles (197 ± 23 vs. 196 ± 22â ms, P = 0.9). Most drivers (81%) originated from areas associated with the structural substrate. The Purkinje system was implicated as a trigger or driver in 43% of patients with cardiomyopathy. The transition to disorganized VF was associated with the acceleration of initial reentrant activities (CL shortening from 187 ± 17 to 175 ± 20â ms, P < 0.001), then spatial dissemination of drivers. Purkinje and substrate ablation resulted in the reduction of VF recurrences from a pre-procedural median of seven episodes [interquartile range (IQR) 4-16] to 0 episode (IQR 0-2) (P < 0.001) at 56 ± 30 months. CONCLUSIONS: The onset of human VF is sustained by activities originating from Purkinje and structural substrate, before spreading throughout the ventricles to establish disorganized VF. Targeted ablation results in effective reduction of VF burden. KEY QUESTION: The initial phase of human ventricular fibrillation (VF) is critical as it involves the primary activities leading to sustained VF and arrhythmic sudden death. The origin of such activities is unknown. KEY FINDING: Body-surface mapping shows that most drivers (≈80%) during the initial VF phase originate from electrophysiologically defined structural substrates. Repetitive Purkinje activities can be elicited by programmed stimulation and are implicated as drivers in 37% of cardiomyopathy patients. TAKE-HOME MESSAGE: The onset of human VF is mostly associated with activities from the Purkinje network and structural substrate, before spreading throughout the ventricles to establish sustained VF. Targeted ablation reduces or eliminates VF recurrence.
Assuntos
Síndrome de Brugada , Ablação por Cateter , Mapeamento Potencial de Superfície Corporal , Ablação por Cateter/métodos , Eletrocardiografia , Ventrículos do Coração , Humanos , Fibrilação VentricularRESUMO
BACKGROUND: Late gadolinium enhancement cardiac magnetic resonance (LGE-CMR) imaging distinguishes between intrinsic postinfarction scar and radiofrequency ablation lesion related scar (dark core lesions [DCLs]) in patients with prior ventricular tachycardia (VT) ablation procedures. OBJECTIVE: To combine LGE-CMR and electroanatomic mapping data to describe the relationship between DCLs and recurrent VT among patients undergoing repeat ablations for postinfarction VT. METHODS: Consecutive patients with repeat ablation for postinfarct VT with LGE-CMR before the repeat procedures were studied. Prior ablation procedures and implantable cardiac defibrillator electrograms were analyzed to determine new versus previously documented VT. DCLs were identified on preprocedure LGE-CMR and registered to electroanatomic maps. A control group of patients undergoing repeat ablation procedures without imaging was included. RESULTS: Nineteen study patients and 14 control patients were followed for 2.6 (1.6-5.6) years (31 [94%] men, age 65.8 ± 8.4 years, ejection fraction 24.7 ± 10.3, p > 0.10 for all). DCLs corresponded to unexcitable tissue during repeat procedures (area 22.4 ± 15.1 vs. 22.9 ± 16.8 cm3 , correlation coefficient = .93). Most VT target sites (39/50 [78%]) were in close proximity (<1 cm) to DCLs. Most DCL related VTs 32/39 (82%) were new VTs. Patients with LGE-CMR imaging incorporated into their ablation procedures had improved 24-month survival from VT (64% vs. 38%, log rank p < 0.02). CONCLUSION: LGE-MRI can identify prior ablation lesions corresponding to nonexcitable tissue during repeat ablation procedures for postinfarction VT. VT target sites are often located in close proximity to the DCL area that may function as a fixed border for reentry circuits. Registration of DCL from prior ablation may facilitate repeat ablation procedures.
Assuntos
Ablação por Cateter , Taquicardia Ventricular , Idoso , Ablação por Cateter/efeitos adversos , Meios de Contraste , Feminino , Gadolínio , Humanos , Imageamento por Ressonância Magnética/métodos , Espectroscopia de Ressonância Magnética , Masculino , Pessoa de Meia-Idade , Taquicardia Ventricular/diagnóstico por imagem , Taquicardia Ventricular/etiologia , Taquicardia Ventricular/cirurgiaRESUMO
BACKGROUND: Focal ventricular arrhythmias (VAs) originating from the intramural myocardium of the basal septum are difficult to localize and ablate. Proximal septal veins emptying into the great cardiac vein can reach close to the origin of intramural arrhythmias. OBJECTIVE: To assess characteristics of proximal septal coronary veins in patients with intramural VAs. METHODS AND RESULTS: Among 84 consecutive patients with intramural VAs, 29 patients (age 60 ± 11years, 16 males, ejection fraction 47 ± 13%) underwent preprocedural cardiac computed tomographic angiography (CTA). In 14 of these patients, the intramural site of origin (SOO) was identified with multipolar catheters. The intramural SOO could not be accessed with mapping catheters in the other 15 patients while mapping the coronary venous system. The CTA identified sizable proximal septal veins in all patients in whom the SOO could be accessed with mapping catheters. In the patients in whom the intramural SOO was not identified, the proximal septal veins were often either small (<2 mm at the branching site) or non-existent (n = 9, p = .001). The proximal septal veins in patients in whom the SOO was identified were larger than in the patients in whom the SOO could not be identified (3.0 ± 0.6 mm vs. 2.1 ± 0.9 mm, p = .01). CONCLUSIONS: Preprocedural imaging with CTAs can be beneficial in identifying the anatomy of proximal septal coronary veins that allow adequate mapping of patients with suspected intramural VAs.