Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 95
Filtrar
Mais filtros

Base de dados
País/Região como assunto
Tipo de documento
Intervalo de ano de publicação
1.
N Engl J Med ; 389(25): 2319-2330, 2023 Dec 21.
Artigo em Inglês | MEDLINE | ID: mdl-38015442

RESUMO

BACKGROUND: Percutaneous coronary intervention (PCI) is frequently performed to reduce the symptoms of stable angina. Whether PCI relieves angina more than a placebo procedure in patients who are not receiving antianginal medication remains unknown. METHODS: We conducted a double-blind, randomized, placebo-controlled trial of PCI in patients with stable angina. Patients stopped all antianginal medications and underwent a 2-week symptom assessment phase before randomization. Patients were then randomly assigned in a 1:1 ratio to undergo PCI or a placebo procedure and were followed for 12 weeks. The primary end point was the angina symptom score, which was calculated daily on the basis of the number of angina episodes that occurred on a given day, the number of antianginal medications prescribed on that day, and clinical events, including the occurrence of unblinding owing to unacceptable angina or acute coronary syndrome or death. Scores range from 0 to 79, with higher scores indicating worse health status with respect to angina. RESULTS: A total of 301 patients underwent randomization: 151 to the PCI group and 150 to the placebo group. The mean (±SD) age was 64±9 years, and 79% were men. Ischemia was present in one cardiac territory in 242 patients (80%), in two territories in 52 patients (17%), and in three territories in 7 patients (2%). In the target vessels, the median fractional flow reserve was 0.63 (interquartile range, 0.49 to 0.75), and the median instantaneous wave-free ratio was 0.78 (interquartile range, 0.55 to 0.87). At the 12-week follow-up, the mean angina symptom score was 2.9 in the PCI group and 5.6 in the placebo group (odds ratio, 2.21; 95% confidence interval, 1.41 to 3.47; P<0.001). One patient in the placebo group had unacceptable angina leading to unblinding. Acute coronary syndromes occurred in 4 patients in the PCI group and in 6 patients in the placebo group. CONCLUSIONS: Among patients with stable angina who were receiving little or no antianginal medication and had objective evidence of ischemia, PCI resulted in a lower angina symptom score than a placebo procedure, indicating a better health status with respect to angina. (Funded by the National Institute for Health and Care Research Imperial Biomedical Research Centre and others; ORBITA-2 ClinicalTrials.gov number, NCT03742050.).


Assuntos
Angina Estável , Intervenção Coronária Percutânea , Idoso , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Síndrome Coronariana Aguda , Angina Estável/tratamento farmacológico , Angina Estável/cirurgia , Fármacos Cardiovasculares/uso terapêutico , Reserva Fracionada de Fluxo Miocárdico , Nível de Saúde , Intervenção Coronária Percutânea/métodos , Resultado do Tratamento , Método Duplo-Cego , Isquemia Miocárdica
2.
Lancet ; 403(10436): 1543-1553, 2024 Apr 20.
Artigo em Inglês | MEDLINE | ID: mdl-38604209

RESUMO

BACKGROUND: The coronary sinus reducer (CSR) is proposed to reduce angina in patients with stable coronary artery disease by improving myocardial perfusion. We aimed to measure its efficacy, compared with placebo, on myocardial ischaemia reduction and symptom improvement. METHODS: ORBITA-COSMIC was a double-blind, randomised, placebo-controlled trial conducted at six UK hospitals. Patients aged 18 years or older with angina, stable coronary artery disease, ischaemia, and no further options for treatment were eligible. All patients completed a quantitative adenosine-stress perfusion cardiac magnetic resonance scan, symptom and quality-of-life questionnaires, and a treadmill exercise test before entering a 2-week symptom assessment phase, in which patients reported their angina symptoms using a smartphone application (ORBITA-app). Patients were randomly assigned (1:1) to receive either CSR or placebo. Both participants and investigators were masked to study assignment. After the CSR implantation or placebo procedure, patients entered a 6-month blinded follow-up phase in which they reported their daily symptoms in the ORBITA-app. At 6 months, all assessments were repeated. The primary outcome was myocardial blood flow in segments designated ischaemic at enrolment during the adenosine-stress perfusion cardiac magnetic resonance scan. The primary symptom outcome was the number of daily angina episodes. Analysis was done by intention-to-treat and followed Bayesian methodology. The study is registered with ClinicalTrials.gov, NCT04892537, and completed. FINDINGS: Between May 26, 2021, and June 28, 2023, 61 patients were enrolled, of whom 51 (44 [86%] male; seven [14%] female) were randomly assigned to either the CSR group (n=25) or the placebo group (n=26). Of these, 50 patients were included in the intention-to-treat analysis (24 in the CSR group and 26 in the placebo group). 454 (57%) of 800 imaged cardiac segments were ischaemic at enrolment, with a median stress myocardial blood flow of 1·08 mL/min per g (IQR 0·77-1·41). Myocardial blood flow in ischaemic segments did not improve with CSR compared with placebo (difference 0·06 mL/min per g [95% CrI -0·09 to 0·20]; Pr(Benefit)=78·8%). The number of daily angina episodes was reduced with CSR compared with placebo (OR 1·40 [95% CrI 1·08 to 1·83]; Pr(Benefit)=99·4%). There were two CSR embolisation events in the CSR group, and no acute coronary syndrome events or deaths in either group. INTERPRETATION: ORBITA-COSMIC found no evidence that the CSR improved transmural myocardial perfusion, but the CSR did improve angina compared with placebo. These findings provide evidence for the use of CSR as a further antianginal option for patients with stable coronary artery disease. FUNDING: Medical Research Council, Imperial College Healthcare Charity, National Institute for Health and Care Research Imperial Biomedical Research Centre, St Mary's Coronary Flow Trust, British Heart Foundation.


Assuntos
Angina Estável , Doença da Artéria Coronariana , Seio Coronário , Intervenção Coronária Percutânea , Humanos , Masculino , Feminino , Doença da Artéria Coronariana/terapia , Angina Estável/tratamento farmacológico , Seio Coronário/diagnóstico por imagem , Teorema de Bayes , Resultado do Tratamento , Intervenção Coronária Percutânea/efeitos adversos , Método Duplo-Cego , Isquemia , Adenosina
3.
J Cardiovasc Magn Reson ; 26(1): 100005, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-38211656

RESUMO

BACKGROUND: Cardiovascular magnetic resonance (CMR) imaging is an important tool for evaluating the severity of aortic stenosis (AS), co-existing aortic disease, and concurrent myocardial abnormalities. Acquiring this additional information requires protocol adaptations and additional scanner time, but is not necessary for the majority of patients who do not have AS. We observed that the relative signal intensity of blood in the ascending aorta on a balanced steady state free precession (bSSFP) 3-chamber cine was often reduced in those with significant aortic stenosis. We investigated whether this effect could be quantified and used to predict AS severity in comparison to existing gold-standard measurements. METHODS: Multi-centre, multi-vendor retrospective analysis of patients with AS undergoing CMR and transthoracic echocardiography (TTE). Blood signal intensity was measured in a ∼1 cm2 region of interest (ROI) in the aorta and left ventricle (LV) in the 3-chamber bSSFP cine. Because signal intensity varied across patients and scanner vendors, a ratio of the mean signal intensity in the aorta ROI to the LV ROI (Ao:LV) was used. This ratio was compared using Pearson correlations against TTE parameters of AS severity: aortic valve peak velocity, mean pressure gradient and the dimensionless index. The study also assessed whether field strength (1.5 T vs. 3 T) and patient characteristics (presence of bicuspid aortic valves (BAV), dilated aortic root and low flow states) altered this signal relationship. RESULTS: 314 patients (median age 69 [IQR 57-77], 64% male) who had undergone both CMR and TTE were studied; 84 had severe AS, 78 had moderate AS, 66 had mild AS and 86 without AS were studied as a comparator group. The median time between CMR and TTE was 12 weeks (IQR 4-26). The Ao:LV ratio at 1.5 T strongly correlated with peak velocity (r = -0.796, p = 0.001), peak gradient (r = -0.772, p = 0.001) and dimensionless index (r = 0.743, p = 0.001). An Ao:LV ratio of < 0.86 was 84% sensitive and 82% specific for detecting AS of any severity and a ratio of 0.58 was 83% sensitive and 92% specific for severe AS. The ability of Ao:LV ratio to predict AS severity remained for patients with bicuspid aortic valves, dilated aortic root or low indexed stroke volume. The relationship between Ao:LV ratio and AS severity was weaker at 3 T. CONCLUSIONS: The Ao:LV ratio, derived from bSSFP 3-chamber cine images, shows a good correlation with existing measures of AS severity. It demonstrates utility at 1.5 T and offers an easily calculable metric that can be used at the time of scanning or automated to identify on an adaptive basis which patients benefit from dedicated imaging to assess which patients should have additional sequences to assess AS.


Assuntos
Estenose da Valva Aórtica , Valva Aórtica , Imagem Cinética por Ressonância Magnética , Valor Preditivo dos Testes , Índice de Gravidade de Doença , Função Ventricular Esquerda , Humanos , Estenose da Valva Aórtica/diagnóstico por imagem , Estenose da Valva Aórtica/fisiopatologia , Feminino , Masculino , Estudos Retrospectivos , Idoso , Pessoa de Meia-Idade , Valva Aórtica/diagnóstico por imagem , Valva Aórtica/fisiopatologia , Valva Aórtica/patologia , Valva Aórtica/anormalidades , Reprodutibilidade dos Testes , Aorta/diagnóstico por imagem , Aorta/fisiopatologia , Interpretação de Imagem Assistida por Computador , Ventrículos do Coração/diagnóstico por imagem , Ventrículos do Coração/fisiopatologia , Fluxo Sanguíneo Regional , Estados Unidos
4.
J Cardiovasc Magn Reson ; 26(1): 101040, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-38522522

RESUMO

BACKGROUND: Late gadolinium enhancement (LGE) of the myocardium has significant diagnostic and prognostic implications, with even small areas of enhancement being important. Distinguishing between definitely normal and definitely abnormal LGE images is usually straightforward, but diagnostic uncertainty arises when reporters are not sure whether the observed LGE is genuine or not. This uncertainty might be resolved by repetition (to remove artifact) or further acquisition of intersecting images, but this must take place before the scan finishes. Real-time quality assurance by humans is a complex task requiring training and experience, so being able to identify which images have an intermediate likelihood of LGE while the scan is ongoing, without the presence of an expert is of high value. This decision-support could prompt immediate image optimization or acquisition of supplementary images to confirm or refute the presence of genuine LGE. This could reduce ambiguity in reports. METHODS: Short-axis, phase-sensitive inversion recovery late gadolinium images were extracted from our clinical cardiac magnetic resonance (CMR) database and shuffled. Two, independent, blinded experts scored each individual slice for "LGE likelihood" on a visual analog scale, from 0 (absolute certainty of no LGE) to 100 (absolute certainty of LGE), with 50 representing clinical equipoise. The scored images were split into two classes-either "high certainty" of whether LGE was present or not, or "low certainty." The dataset was split into training, validation, and test sets (70:15:15). A deep learning binary classifier based on the EfficientNetV2 convolutional neural network architecture was trained to distinguish between these categories. Classifier performance on the test set was evaluated by calculating the accuracy, precision, recall, F1-score, and area under the receiver operating characteristics curve (ROC AUC). Performance was also evaluated on an external test set of images from a different center. RESULTS: One thousand six hundred and forty-five images (from 272 patients) were labeled and split at the patient level into training (1151 images), validation (247 images), and test (247 images) sets for the deep learning binary classifier. Of these, 1208 images were "high certainty" (255 for LGE, 953 for no LGE), and 437 were "low certainty". An external test comprising 247 images from 41 patients from another center was also employed. After 100 epochs, the performance on the internal test set was accuracy = 0.94, recall = 0.80, precision = 0.97, F1-score = 0.87, and ROC AUC = 0.94. The classifier also performed robustly on the external test set (accuracy = 0.91, recall = 0.73, precision = 0.93, F1-score = 0.82, and ROC AUC = 0.91). These results were benchmarked against a reference inter-expert accuracy of 0.86. CONCLUSION: Deep learning shows potential to automate quality control of late gadolinium imaging in CMR. The ability to identify short-axis images with intermediate LGE likelihood in real-time may serve as a useful decision-support tool. This approach has the potential to guide immediate further imaging while the patient is still in the scanner, thereby reducing the frequency of recalls and inconclusive reports due to diagnostic indecision.


Assuntos
Meios de Contraste , Aprendizado Profundo , Interpretação de Imagem Assistida por Computador , Valor Preditivo dos Testes , Humanos , Meios de Contraste/administração & dosagem , Reprodutibilidade dos Testes , Interpretação de Imagem Assistida por Computador/normas , Bases de Dados Factuais , Miocárdio/patologia , Masculino , Feminino , Imagem Cinética por Ressonância Magnética/normas , Pessoa de Meia-Idade , Cardiopatias/diagnóstico por imagem , Garantia da Qualidade dos Cuidados de Saúde/normas , Variações Dependentes do Observador , Idoso , Imageamento por Ressonância Magnética/normas
5.
Europace ; 25(3): 1060-1067, 2023 03 30.
Artigo em Inglês | MEDLINE | ID: mdl-36734205

RESUMO

AIMS: Left bundle branch area pacing (LBBAP) is a promising method for delivering cardiac resynchronization therapy (CRT), but its relative physiological effectiveness compared with His bundle pacing (HBP) is unknown. We conducted a within-patient comparison of HBP, LBBAP, and biventricular pacing (BVP). METHODS AND RESULTS: Patients referred for CRT were recruited. We assessed electrical response using non-invasive mapping, and acute haemodynamic response using a high-precision haemodynamic protocol. Nineteen patients were recruited: 14 male, mean LVEF of 30%. Twelve had time for BVP measurements. All three modalities reduced total ventricular activation time (TVAT), (ΔTVATHBP -43 ± 14 ms and ΔTVATLBBAP -35 ± 20 ms vs. ΔTVATBVP -19 ± 30 ms, P = 0.03 and P = 0.1, respectively). HBP produced a significantly greater reduction in TVAT compared with LBBAP in all 19 patients (-46 ± 15 ms, -36 ± 17 ms, P = 0.03). His bundle pacing and LBBAP reduced left ventricular activation time (LVAT) more than BVP (ΔLVATHBP -43 ± 16 ms, P < 0.01 vs. BVP, ΔLVATLBBAP -45 ± 17 ms, P < 0.01 vs. BVP, ΔLVATBVP -13 ± 36 ms), with no difference between HBP and LBBAP (P = 0.65). Acute systolic blood pressure was increased by all three modalities. In the 12 with BVP, greater improvement was seen with HBP and LBBAP (6.4 ± 3.8 mmHg BVP, 8.1 ± 3.8 mmHg HBP, P = 0.02 vs. BVP and 8.4 ± 8.2 mmHg for LBBAP, P = 0.3 vs. BVP), with no difference between HBP and LBBAP (P = 0.8). CONCLUSION: HBP delivered better ventricular resynchronization than LBBAP because right ventricular activation was slower during LBBAP. But LBBAP was not inferior to HBP with respect to LV electrical resynchronization and acute haemodynamic response.


Assuntos
Terapia de Ressincronização Cardíaca , Insuficiência Cardíaca , Humanos , Masculino , Fascículo Atrioventricular , Terapia de Ressincronização Cardíaca/efeitos adversos , Terapia de Ressincronização Cardíaca/métodos , Bloqueio de Ramo/diagnóstico , Bloqueio de Ramo/terapia , Eletrocardiografia/métodos , Resultado do Tratamento , Insuficiência Cardíaca/diagnóstico , Insuficiência Cardíaca/terapia , Hemodinâmica , Estimulação Cardíaca Artificial/métodos
6.
Europace ; 25(10)2023 10 05.
Artigo em Inglês | MEDLINE | ID: mdl-37815462

RESUMO

AIMS: Left bundle branch pacing (LBBP) can deliver physiological left ventricular activation, but typically at the cost of delayed right ventricular (RV) activation. Right ventricular activation can be advanced through anodal capture, but there is uncertainty regarding the mechanism by which this is achieved, and it is not known whether this produces haemodynamic benefit. METHODS AND RESULTS: We recruited patients with LBBP leads in whom anodal capture eliminated the terminal R-wave in lead V1. Ventricular activation pattern, timing, and high-precision acute haemodynamic response were studied during LBBP with and without anodal capture. We recruited 21 patients with a mean age of 67 years, of whom 14 were males. We measured electrocardiogram timings and haemodynamics in all patients, and in 16, we also performed non-invasive mapping. Ventricular epicardial propagation maps demonstrated that RV septal myocardial capture, rather than right bundle capture, was the mechanism for earlier RV activation. With anodal capture, QRS duration and total ventricular activation times were shorter (116 ± 12 vs. 129 ± 14 ms, P < 0.01 and 83 ± 18 vs. 90 ± 15 ms, P = 0.01). This required higher outputs (3.6 ± 1.9 vs. 0.6 ± 0.2 V, P < 0.01) but without additional haemodynamic benefit (mean difference -0.2 ± 3.8 mmHg compared with pacing without anodal capture, P = 0.2). CONCLUSION: Left bundle branch pacing with anodal capture advances RV activation by stimulating the RV septal myocardium. However, this requires higher outputs and does not improve acute haemodynamics. Aiming for anodal capture may therefore not be necessary.


Assuntos
Fascículo Atrioventricular , Estimulação Cardíaca Artificial , Masculino , Humanos , Idoso , Feminino , Estimulação Cardíaca Artificial/métodos , Sistema de Condução Cardíaco , Hemodinâmica , Ventrículos do Coração , Eletrocardiografia/métodos
7.
Pacing Clin Electrophysiol ; 46(9): 1077-1084, 2023 09.
Artigo em Inglês | MEDLINE | ID: mdl-37594233

RESUMO

BACKGROUND: The use of left bundle branch area pacing (LBBAP) for bradycardia pacing and cardiac resynchronization is increasing, but implants are not always successful. We prospectively studied consecutive patients to determine whether septal scar contributes to implant failure. METHODS: Patients scheduled for bradycardia pacing or cardiac resynchronization therapy were prospectively enrolled. Recruited patients underwent preprocedural scar assessment by cardiac MRI with late gadolinium enhancement imaging. LBBAP was attempted using a lumenless lead (Medtronic 3830) via a transeptal approach. RESULTS: Thirty-five patients were recruited: 29 male, mean age 68 years, 10 ischemic, and 16 non-ischemic cardiomyopathy. Pacing indication was bradycardia in 26% and cardiac resynchronization in 74%. The lead was successfully deployed to the left ventricular septum in 30/35 (86%) and unsuccessful in the remaining 5/35 (14%). Septal late gadolinium enhancement was significantly less extensive in patients where left septal lead deployment was successful, compared those where it was unsuccessful (median 8%, IQR 2%-18% vs. median 54%, IQR 53%-57%, p < .001). CONCLUSIONS: The presence of septal scar appears to make it more challenging to deploy a lead to the left ventricular septum via the transeptal route. Additional implant tools or alternative approaches may be required in patients with extensive septal scar.


Assuntos
Septo Interventricular , Humanos , Masculino , Idoso , Septo Interventricular/diagnóstico por imagem , Bradicardia , Cicatriz , Meios de Contraste , Gadolínio
8.
Eur Heart J ; 42(19): 1866-1878, 2021 05 14.
Artigo em Inglês | MEDLINE | ID: mdl-33596594

RESUMO

BACKGROUND: Troponin elevation is common in hospitalized COVID-19 patients, but underlying aetiologies are ill-defined. We used multi-parametric cardiovascular magnetic resonance (CMR) to assess myocardial injury in recovered COVID-19 patients. METHODS AND RESULTS: One hundred and forty-eight patients (64 ± 12 years, 70% male) with severe COVID-19 infection [all requiring hospital admission, 48 (32%) requiring ventilatory support] and troponin elevation discharged from six hospitals underwent convalescent CMR (including adenosine stress perfusion if indicated) at median 68 days. Left ventricular (LV) function was normal in 89% (ejection fraction 67% ± 11%). Late gadolinium enhancement and/or ischaemia was found in 54% (80/148). This comprised myocarditis-like scar in 26% (39/148), infarction and/or ischaemia in 22% (32/148) and dual pathology in 6% (9/148). Myocarditis-like injury was limited to three or less myocardial segments in 88% (35/40) of cases with no associated LV dysfunction; of these, 30% had active myocarditis. Myocardial infarction was found in 19% (28/148) and inducible ischaemia in 26% (20/76) of those undergoing stress perfusion (including 7 with both infarction and ischaemia). Of patients with ischaemic injury pattern, 66% (27/41) had no past history of coronary disease. There was no evidence of diffuse fibrosis or oedema in the remote myocardium (T1: COVID-19 patients 1033 ± 41 ms vs. matched controls 1028 ± 35 ms; T2: COVID-19 46 ± 3 ms vs. matched controls 47 ± 3 ms). CONCLUSIONS: During convalescence after severe COVID-19 infection with troponin elevation, myocarditis-like injury can be encountered, with limited extent and minimal functional consequence. In a proportion of patients, there is evidence of possible ongoing localized inflammation. A quarter of patients had ischaemic heart disease, of which two-thirds had no previous history. Whether these observed findings represent pre-existing clinically silent disease or de novo COVID-19-related changes remain undetermined. Diffuse oedema or fibrosis was not detected.


Assuntos
COVID-19 , Miocardite , Meios de Contraste , Feminino , Gadolínio , Humanos , Imagem Cinética por Ressonância Magnética , Espectroscopia de Ressonância Magnética , Masculino , Miocardite/diagnóstico por imagem , Miocárdio , Valor Preditivo dos Testes , SARS-CoV-2 , Troponina , Função Ventricular Esquerda
9.
J Cardiovasc Magn Reson ; 23(1): 126, 2021 11 08.
Artigo em Inglês | MEDLINE | ID: mdl-34743718

RESUMO

BACKGROUND: Quantitative cardiovascular magnetic resonance (CMR) T1 and T2 mapping are used to detect diffuse disease such as myocardial fibrosis or edema. However, post gadolinium contrast mapping often lacks visual contrast needed for assessment of focal scar. On the other hand, late gadolinium enhancement (LGE) CMR which nulls the normal myocardium has excellent contrast between focal scar and normal myocardium but has poor ability to detect global disease. The objective of this work is to provide a calculated bright-blood (BB) and dark-blood (DB) LGE based on simultaneous acquisition of T1 and T2 maps, so that both diffuse and focal disease may be assessed within a single multi-parametric acquisition. METHODS: The prototype saturation recovery-based SASHA T1 mapping may be modified to jointly calculate T1 and T2 maps (known as multi-parametric SASHA) by acquiring additional saturation recovery (SR) images with both SR and T2 preparations. The synthetic BB phase sensitive inversion recovery (PSIR) LGE may be calculated from the post-contrast T1, and the DB PSIR LGE may be calculated from the post-contrast joint T1 and T2 maps. Multi-parametric SASHA maps were acquired free-breathing (45 heartbeats). Protocols were designed to use the same spatial resolution and achieve similar signal-to-noise ratio (SNR) as conventional motion corrected (MOCO) PSIR. The calculated BB and DB LGE were compared with separate free breathing (FB) BB and DB MOCO PSIR acquisitions requiring 16 and 32 heart beats, respectively. One slice with myocardial infarction (MI) was acquired with all protocols within 4 min. RESULTS: Multiparametric T1 and T2 maps and calculated BB and DB PSIR LGE images were acquired for patients with subendocardial chronic MI (n = 10), acute MI (n = 3), and myocarditis (n = 1). The contrast-to-noise (CNR) between scar (MI and myocarditis) and remote was 26.6 ± 7.7 and 20.2 ± 7.4 for BB and DB PSIR LGE, and 31.3 ± 10.6 and 21.8 ± 7.6 for calculated BB and DB PSIR LGE, respectively. The CNR between scar and the left ventricualr blood pool was 5.2 ± 6.5 and 29.7 ± 9.4 for conventional BB and DB PSIR LGE, and 6.5 ± 6.0 and 38.6 ± 11.6 for calculated BB and DB PSIR LGE, respectively. CONCLUSIONS: A single free-breathing acquisition using multi-parametric SASHA provides T1 and T2 maps and calculated BB and DB PSIR LGE images for comprehensive tissue characterization.


Assuntos
Meios de Contraste , Gadolínio , Humanos , Imageamento por Ressonância Magnética , Miocárdio , Valor Preditivo dos Testes , Reprodutibilidade dos Testes
10.
Age Ageing ; 50(4): 1064-1068, 2021 06 28.
Artigo em Inglês | MEDLINE | ID: mdl-33837764

RESUMO

Heart failure (HF) can be considered a disease of older people. It is a leading cause of hospitalisation and is associated with high rates of morbidity and mortality in the over-65s. In 2012, an editorial in this journal detailed the latest HF research and guidelines, calling for greater integration of geriatricians in HF care. This current article reflects upon what has been achieved in this field in recent years, highlighting some future challenges and promising areas. It is written from the perspective of one such integrated team and explores the new role of cardiogeriatrician, working in a multidisciplinary team to deliver and improve care to increasingly complex, older, frail patients with multiple comorbidities who present with primary cardiology problems, especially decompensated HF. Geriatric liaison has improved the care of frail patients in orthopaedics, cancer services, stroke, acute medicine and numerous community settings. We propose that this vital role should now be extended to cardiology teams in general and to HF in particular.


Assuntos
Cardiologia , Insuficiência Cardíaca , Idoso , Comorbidade , Geriatras , Insuficiência Cardíaca/diagnóstico , Insuficiência Cardíaca/epidemiologia , Insuficiência Cardíaca/terapia , Hospitalização , Humanos
11.
BMC Med Educ ; 21(1): 429, 2021 Aug 14.
Artigo em Inglês | MEDLINE | ID: mdl-34391424

RESUMO

BACKGROUND: Artificial intelligence (AI) technologies are increasingly used in clinical practice. Although there is robust evidence that AI innovations can improve patient care, reduce clinicians' workload and increase efficiency, their impact on medical training and education remains unclear. METHODS: A survey of trainee doctors' perceived impact of AI technologies on clinical training and education was conducted at UK NHS postgraduate centers in London between October and December 2020. Impact assessment mirrored domains in training curricula such as 'clinical judgement', 'practical skills' and 'research and quality improvement skills'. Significance between Likert-type data was analysed using Fisher's exact test. Response variations between clinical specialities were analysed using k-modes clustering. Free-text responses were analysed by thematic analysis. RESULTS: Two hundred ten doctors responded to the survey (response rate 72%). The majority (58%) perceived an overall positive impact of AI technologies on their training and education. Respondents agreed that AI would reduce clinical workload (62%) and improve research and audit training (68%). Trainees were skeptical that it would improve clinical judgement (46% agree, p = 0.12) and practical skills training (32% agree, p < 0.01). The majority reported insufficient AI training in their current curricula (92%), and supported having more formal AI training (81%). CONCLUSIONS: Trainee doctors have an overall positive perception of AI technologies' impact on clinical training. There is optimism that it will improve 'research and quality improvement' skills and facilitate 'curriculum mapping'. There is skepticism that it may reduce educational opportunities to develop 'clinical judgement' and 'practical skills'. Medical educators should be mindful that these domains are protected as AI develops. We recommend that 'Applied AI' topics are formalized in curricula and digital technologies leveraged to deliver clinical education.


Assuntos
Inteligência Artificial , Médicos , Humanos , Londres , Percepção , Inquéritos e Questionários , Reino Unido
12.
Perfusion ; 36(6): 547-558, 2021 09.
Artigo em Inglês | MEDLINE | ID: mdl-33427055

RESUMO

The COVID-19 pandemic has altered our approach to inpatient echocardiography delivery. There is now a greater focus to address key clinical questions likely to make an immediate impact in management, particularly during the period of widespread infection. Handheld echocardiography (HHE) can be used as a first-line assessment tool, limiting scanning time and exposure to high viral load. This article describes a potential role for HHE during a pandemic. We propose a protocol with a reporting template for a focused core dataset necessary in delivering an acute echocardiography service in the setting of a highly contagious disease, minimising risk to the operator. We cover the scenarios typically encountered in the acute cardiology setting and how an expert trained echocardiography team can identify such pathologies using a limited imaging format and include cardiac presentations encountered in those patients acutely unwell with COVID-19.


Assuntos
COVID-19 , Cardiologia , Ecocardiografia , Humanos , Pandemias , SARS-CoV-2
13.
Circulation ; 140(24): 1971-1980, 2019 12 10.
Artigo em Inglês | MEDLINE | ID: mdl-31707827

RESUMO

BACKGROUND: Dobutamine stress echocardiography is widely used to test for ischemia in patients with stable coronary artery disease. In this analysis, we studied the ability of the prerandomization stress echocardiography score to predict the placebo-controlled efficacy of percutaneous coronary intervention (PCI) within the ORBITA trial (Objective Randomised Blinded Investigation With Optimal Medical Therapy of Angioplasty in Stable Angina). METHODS: One hundred eighty-three patients underwent dobutamine stress echocardiography before randomization. The stress echocardiography score is broadly the number of segments abnormal at peak stress, with akinetic segments counting double and dyskinetic segments counting triple. The ability of prerandomization stress echocardiography to predict the placebo-controlled effect of PCI on response variables was tested by using regression modeling. RESULTS: At prerandomization, the stress echocardiography score was 1.56±1.77 in the PCI arm (n=98) and 1.61±1.73 in the placebo arm (n=85). There was a detectable interaction between prerandomization stress echocardiography score and the effect of PCI on angina frequency score with a larger placebo-controlled effect in patients with the highest stress echocardiography score (Pinteraction=0.031). With our sample size, we were unable to detect an interaction between stress echocardiography score and any other patient-reported response variables: freedom from angina (Pinteraction=0.116), physical limitation (Pinteraction=0.461), quality of life (Pinteraction=0.689), EuroQOL 5 quality-of-life score (Pinteraction=0.789), or between stress echocardiography score and physician-assessed Canadian Cardiovascular Society angina class (Pinteraction=0.693), and treadmill exercise time (Pinteraction=0.426). CONCLUSIONS: The degree of ischemia assessed by dobutamine stress echocardiography predicts the placebo-controlled efficacy of PCI on patient-reported angina frequency. The greater the downstream stress echocardiography abnormality caused by a stenosis, the greater the reduction in symptoms from PCI. CLINICAL TRIAL REGISTRATION: URL: https://www.clinicaltrials.gov. Unique identifier: NCT02062593.


Assuntos
Doença da Artéria Coronariana/tratamento farmacológico , Dobutamina/farmacologia , Ecocardiografia sob Estresse/efeitos dos fármacos , Isquemia/tratamento farmacológico , Idoso , Angina Estável/diagnóstico , Angina Estável/tratamento farmacológico , Doença da Artéria Coronariana/diagnóstico , Dobutamina/administração & dosagem , Tolerância ao Exercício/efeitos dos fármacos , Feminino , Humanos , Isquemia/etiologia , Isquemia/fisiopatologia , Masculino , Pessoa de Meia-Idade , Intervenção Coronária Percutânea/efeitos adversos , Qualidade de Vida
14.
Circulation ; 138(17): 1780-1792, 2018 10 23.
Artigo em Inglês | MEDLINE | ID: mdl-29789302

RESUMO

BACKGROUND: There are no data on how fractional flow reserve (FFR) and instantaneous wave-free ratio (iFR) are associated with the placebo-controlled efficacy of percutaneous coronary intervention (PCI) in stable single-vessel coronary artery disease. METHODS: We report the association between prerandomization invasive physiology within ORBITA (Objective Randomised Blinded Investigation With Optimal Medical Therapy of Angioplasty in Stable Angina), a placebo-controlled trial of patients who have stable angina with angiographically severe single-vessel coronary disease clinically eligible for PCI. Patients underwent prerandomization research FFR and iFR assessment. The operator was blinded to these values. Assessment of response variables, treadmill exercise time, stress echocardiography score, symptom frequency, and angina severity were performed at prerandomization and blinded follow-up. Effects were calculated by analysis of covariance. The ability of FFR and iFR to predict placebo-controlled changes in response variables was tested by using regression modeling. RESULTS: Invasive physiology data were available in 196 patients (103 PCI and 93 placebo). At prerandomization, the majority had Canadian Cardiovascular Society class II or III symptoms (150/196, 76.5%). Mean FFR and iFR were 0.69±0.16 and 0.76±0.22, respectively; 97% had ≥1 positive ischemia tests. The estimated effect of PCI on between-arm prerandomization-adjusted total exercise time was 20.7 s (95% confidence interval [CI], -4.0 to 45.5; P=0.100) with no interaction of FFR ( Pinteraction=0.318) or iFR ( Pinteraction=0.523). PCI improved stress echocardiography score more than placebo (1.07 segment units; 95% CI, 0.70-1.44; P<0.00001). The placebo-controlled effect of PCI on stress echocardiography score increased progressively with decreasing FFR ( Pinteraction<0.00001) and decreasing iFR ( Pinteraction<0.00001). PCI did not improve angina frequency score significantly more than placebo (odds ratio, 1.64; 95% CI, 0.96-2.80; P=0.072) with no detectable evidence of interaction with FFR ( Pinteraction=0.849) or iFR ( Pinteraction=0.783). However, PCI resulted in more patient-reported freedom from angina than placebo (49.5% versus 31.5%; odds ratio, 2.47; 95% CI, 1.30-4.72; P=0.006) but neither FFR ( Pinteraction=0.693) nor iFR ( Pinteraction=0.761) modified this effect. CONCLUSIONS: In patients with stable angina and severe single-vessel disease, the blinded effect of PCI was more clearly seen by stress echocardiography score and freedom from angina than change in treadmill exercise time. Moreover, the lower the FFR or iFR, the greater the magnitude of stress echocardiographic improvement caused by PCI. CLINICAL TRIAL REGISTRATION: URL: https://www.clinicaltrials.gov . Unique identifier: NCT02062593.


Assuntos
Angina Estável/terapia , Cateterismo Cardíaco , Doença da Artéria Coronariana/terapia , Estenose Coronária/terapia , Reserva Fracionada de Fluxo Miocárdico , Intervenção Coronária Percutânea , Agonistas de Receptores Adrenérgicos beta 1/administração & dosagem , Idoso , Angina Estável/diagnóstico , Angina Estável/fisiopatologia , Angiografia Coronária , Doença da Artéria Coronariana/diagnóstico , Doença da Artéria Coronariana/fisiopatologia , Estenose Coronária/diagnóstico , Estenose Coronária/fisiopatologia , Dobutamina/administração & dosagem , Ecocardiografia sob Estresse/métodos , Teste de Esforço , Tolerância ao Exercício , Feminino , Nível de Saúde , Humanos , Masculino , Pessoa de Meia-Idade , Intervenção Coronária Percutânea/efeitos adversos , Valor Preditivo dos Testes , Intervalo Livre de Progressão , Qualidade de Vida , Recuperação de Função Fisiológica , Índice de Gravidade de Doença , Fatores de Tempo , Reino Unido
15.
Eur Heart J ; 38(22): 1738-1746, 2017 Jun 07.
Artigo em Inglês | MEDLINE | ID: mdl-28329280

RESUMO

AIMS: Primary prevention implantable cardioverter defibrillators (ICDs) are established therapy for reducing mortality in patients with left ventricular systolic dysfunction and ischaemic heart disease (IHD). However, their efficacy in patients without IHD has been controversial. We undertook a meta-analysis of the totality of the evidence. METHODS AND RESULTS: We systematically identified all RCTs comparing ICD vs. no ICD in primary prevention. Eligible RCTs were those that recruited patients with left ventricular dysfunction, reported all-cause mortality, and presented their results stratified by the presence of IHD (or recruited only those with or without). Our primary endpoint was all-cause mortality. We identified 11 studies enrolling 8567 participants with left ventricular dysfunction, including 3128 patients without IHD and 5439 patients with IHD. In patients without IHD, ICD therapy reduced mortality by 24% (HR 0.76, 95% CI 0.64 to 0.90, P = 0.001). In patients with IHD, ICD implantation (at a dedicated procedure), also reduced mortality by 24% (HR 0.76, 95% CI 0.60 to 0.96, P = 0.02). CONCLUSIONS: Until now, it has never been explicitly stated that the patients without IHD in COMPANION showed significant survival benefit from adding ICD therapy (to a background of CRT). Even before DANISH, meta-analysis of patients without ischaemic heart disease already showed reduced mortality. DANISH is consistent with these data. With a significant 24% mortality reduction in both aetiologies, it may no longer be necessary to distinguish between them when deciding on primary prevention ICD implantation.


Assuntos
Morte Súbita Cardíaca/prevenção & controle , Desfibriladores Implantáveis , Isquemia Miocárdica/complicações , Disfunção Ventricular Esquerda/complicações , Humanos , Pessoa de Meia-Idade , Isquemia Miocárdica/mortalidade , Ensaios Clínicos Controlados Aleatórios como Assunto , Disfunção Ventricular Esquerda/mortalidade
16.
Echocardiography ; 34(7): 956-967, 2017 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-28573718

RESUMO

BACKGROUND: Correctly selecting the end-diastolic and end-systolic frames on a 2D echocardiogram is important and challenging, for both human experts and automated algorithms. Manual selection is time-consuming and subject to uncertainty, and may affect the results obtained, especially for advanced measurements such as myocardial strain. METHODS AND RESULTS: We developed and evaluated algorithms which can automatically extract global and regional cardiac velocity, and identify end-diastolic and end-systolic frames. We acquired apical four-chamber 2D echocardiographic video recordings, each at least 10 heartbeats long, acquired twice at frame rates of 52 and 79 frames/s from 19 patients, yielding 38 recordings. Five experienced echocardiographers independently marked end-systolic and end-diastolic frames for the first 10 heartbeats of each recording. The automated algorithm also did this. Using the average of time points identified by five human operators as the reference gold standard, the individual operators had a root mean square difference from that gold standard of 46.5 ms. The algorithm had a root mean square difference from the human gold standard of 40.5 ms (P<.0001). Put another way, the algorithm-identified time point was an outlier in 122/564 heartbeats (21.6%), whereas the average human operator was an outlier in 254/564 heartbeats (45%). CONCLUSION: An automated algorithm can identify the end-systolic and end-diastolic frames with performance indistinguishable from that of human experts. This saves staff time, which could therefore be invested in assessing more beats, and reduces uncertainty about the reliability of the choice of frame.


Assuntos
Ecocardiografia/métodos , Coração/diagnóstico por imagem , Coração/fisiologia , Adulto , Idoso , Idoso de 80 Anos ou mais , Algoritmos , Diástole , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Variações Dependentes do Observador , Reprodutibilidade dos Testes , Sístole
18.
Eur Heart J ; 35(36): 2435-40, 2014 Sep 21.
Artigo em Inglês | MEDLINE | ID: mdl-25371927

RESUMO

Erroneous research results have potential for harm far beyond the patients recruited into the study, because the leverage of leadership permits them to alter behaviour of thousands of clinicians for many years. Medical research does not yet have as well-developed and rapid-responding safety systems as other spheres where lives are at stake. As doctors we would all leap to assist in a medical emergency for a patient not formally under our care. Yet, when problems occur in clinical research, we do not yet have good mechanisms to all work together quickly and decisively to improve patient safety. In this article we describe how each of us, regardless of our role, can (and perhaps should) take active steps to support delivery of reliable science for patient care.


Assuntos
Pesquisa Biomédica/normas , Segurança do Paciente/normas , Guias de Prática Clínica como Assunto , Revelação , Humanos , Má Conduta Profissional , Projetos de Pesquisa/normas
19.
Europace ; 16(4): 541-50, 2014 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-24068445

RESUMO

AIMS: Full-disclosure study describing Doppler patterns during iterative atrioventricular delay (AVD) optimization of biventricular pacemakers (cardiac resynchronization therapy, CRT). METHOD AND RESULTS: Doppler traces of the first 50 eligible patients undergoing iterative Doppler AVD optimization in the BRAVO trial were examined. Three experienced observers classified conformity to guideline-described patterns. Each observer then selected the optimum AVD on two separate occasions: blinded and unblinded to AVD. Four Doppler E-A patterns occurred: A (always merged, 18% of patients), B (incrementally less fusion at short AVDs, 12%), C (full separation at short AVDs, as described by the guidelines, 28%), and D (always separated, 42%). In Groups A and D (60%), the iterative guidelines therefore cannot specify one single AVD. On the kappa scale (0 = chance alone; 1 = perfect agreement), observer agreement for the ideal AVD in Classes B and C was poor (0.32) and appeared worse in Groups A and D (0.22). Blinding caused the scattering of the AVD selected as optimal to widen (standard deviation rising from 37 to 49 ms, P < 0.001). By blinding 28% of the selected optimum AVDs were ≤60 or ≥200 ms. All 50 Doppler datasets are presented, to support future methodological testing. CONCLUSION: In most patients, the iterative method does not clearly specify one AVD. In all the patients, agreement on the ideal AVD between skilled observers viewing identical images is poor. The iterative protocol may successfully exclude some extremely unsuitable AVDs, but so might simply accepting factory default. Irreproducibility of the gold standard also prevents alternative physiological optimization methods from being validated honestly.


Assuntos
Dispositivos de Terapia de Ressincronização Cardíaca , Terapia de Ressincronização Cardíaca , Ecocardiografia Doppler , Sistema de Condução Cardíaco/diagnóstico por imagem , Insuficiência Cardíaca/diagnóstico por imagem , Insuficiência Cardíaca/terapia , Valva Mitral/diagnóstico por imagem , Idoso , Desenho de Equipamento , Feminino , Sistema de Condução Cardíaco/fisiopatologia , Insuficiência Cardíaca/fisiopatologia , Humanos , Masculino , Pessoa de Meia-Idade , Valva Mitral/fisiopatologia , Variações Dependentes do Observador , Valor Preditivo dos Testes , Ensaios Clínicos Controlados Aleatórios como Assunto , Reprodutibilidade dos Testes , Resultado do Tratamento
20.
Echo Res Pract ; 11(1): 16, 2024 Jun 03.
Artigo em Inglês | MEDLINE | ID: mdl-38825710

RESUMO

Impairment of left ventricular (LV) diastolic function is common amongst those with left heart disease and is associated with significant morbidity. Given that, in simple terms, the ventricle can only eject the volume with which it fills and that approximately one half of hospitalisations for heart failure (HF) are in those with normal/'preserved' left ventricular ejection fraction (HFpEF) (Bianco et al. in JACC Cardiovasc Imaging. 13:258-271, 2020. 10.1016/j.jcmg.2018.12.035), where abnormalities of ventricular filling are the cause of symptoms, it is clear that the assessment of left ventricular diastolic function (LVDF) is crucial for understanding global cardiac function and for identifying the wider effects of disease processes. Invasive methods of measuring LV relaxation and filling pressures are considered the gold-standard for investigating diastolic function. However, the high temporal resolution of trans-thoracic echocardiography (TTE) with widely validated and reproducible measures available at the patient's bedside and without the need for invasive procedures involving ionising radiation have established echocardiography as the primary imaging modality. The comprehensive assessment of LVDF is therefore a fundamental element of the standard TTE (Robinson et al. in Echo Res Pract7:G59-G93, 2020. 10.1530/ERP-20-0026). However, the echocardiographic assessment of diastolic function is complex. In the broadest and most basic terms, ventricular diastole comprises an early filling phase when blood is drawn, by suction, into the ventricle as it rapidly recoils and lengthens following the preceding systolic contraction and shortening. This is followed in late diastole by distension of the compliant LV when atrial contraction actively contributes to ventricular filling. When LVDF is normal, ventricular filling is achieved at low pressure both at rest and during exertion. However, this basic description merely summarises the complex physiology that enables the diastolic process and defines it according to the mechanical method by which the ventricles fill, overlooking the myocardial function, properties of chamber compliance and pressure differentials that determine the capacity for LV filling. Unlike ventricular systolic function where single parameters are utilised to define myocardial performance (LV ejection fraction (LVEF) and Global Longitudinal Strain (GLS)), the assessment of diastolic function relies on the interpretation of multiple myocardial and blood-flow velocity parameters, along with left atrial (LA) size and function, in order to diagnose the presence and degree of impairment. The echocardiographic assessment of diastolic function is therefore multifaceted and complex, requiring an algorithmic approach that incorporates parameters of myocardial relaxation/recoil, chamber compliance and function under variable loading conditions and the intra-cavity pressures under which these processes occur. This guideline outlines a structured approach to the assessment of diastolic function and includes recommendations for the assessment of LV relaxation and filling pressures. Non-routine echocardiographic measures are described alongside guidance for application in specific circumstances. Provocative methods for revealing increased filling pressure on exertion are described and novel and emerging modalities considered. For rapid access to the core recommendations of the diastolic guideline, a quick-reference guide (additional file 1) accompanies the main guideline document. This describes in very brief detail the diastolic investigation in each patient group and includes all algorithms and core reference tables.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA