Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 11 de 11
Filtrar
1.
Eur J Orthop Surg Traumatol ; 33(7): 3051-3058, 2023 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-37000241

RESUMO

PURPOSE: We investigated bacterial propagation through multifilament, monofilament sutures and whether sutures coated with triclosan would exhibit a different phenomenon. METHODS: One centimetre (cm) wide trenches were cut in the middle of Columbia blood Agar plates. We tested a 6 cm length of two Triclosan-coated (PDS plus®, Vicryl plus®) and two uncoated (PDS ®, Vicryl ®) sutures. Each suture was inoculated with a bacterial suspension containing methicillin-sensitive Staphylococcus aureus (MSSA), Escherichia coli (E. coli), Staphylococcus epidermidis, methicillin-resistant Staphylococcus aureus (MRSA) at one end of each suture. The plates were incubated at 36C for 48 h, followed by room temperature for a further 5 days. We established bacterial propagation by observing for any bacterial growth on the Agar on the opposite side of the trench. RESULTS: Bacterial propagation was observed on the opposite side of the trench with both suture types, monofilament PDS and multifilament Vicryl, when tested with the motile bacterium (E. coli). Propagation was not observed on the other side of the trench with the monofilament PDS suture following incubation with MSSA and S. epidermidis, and in 66% of MRSA. With multifilament suture Vicryl, propagation was observed on the other side of the trench in 90% (MSSA), 80% (S. epidermidis), and 100% (MRSA) of plates tested. No bacterial propagation was observed in any of the triclosan-coated sutures (monofilament or multifilament). CONCLUSIONS: Monofilament sutures are associated in vitro with less bacterial propagation along their course when compared to multifilament sutures. Inhibition in both sutures can be further enhanced with a triclosan coating.


Assuntos
Anti-Infecciosos Locais , Staphylococcus aureus Resistente à Meticilina , Infecções Estafilocócicas , Triclosan , Humanos , Triclosan/farmacologia , Anti-Infecciosos Locais/farmacologia , Escherichia coli , Infecção da Ferida Cirúrgica/prevenção & controle , Infecção da Ferida Cirúrgica/microbiologia , Poliglactina 910 , Ágar , Staphylococcus aureus , Staphylococcus epidermidis , Meticilina , Suturas
2.
Ann R Coll Surg Engl ; 87(2): 123-5, 2005 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-15826424

RESUMO

INTRODUCTION: To assess the effectiveness of infection control measures (pre-admission screening and patient segregation) on reducing in-patient exposure to methicillin-resistant Staphylococcus aureus (MRSA). PATIENTS AND METHODS: A prospective case-control study in a district general hospital. All admissions to 3 wards over an 83-month period from September 1995 to July 2002 inclusive (a total of approximately 34,000 patients). Outcome measures were a statistical analysis of the difference in numbers of new cases of MRSA colonisation or infection between the 3 wards. RESULTS: There was a statistical significance in incidence of new MRSA cases between the ward with active infection control measures in place and the control wards. CONCLUSIONS: The described infection control measures reduced the exposure of patients to MRSA. This reduces the risk of MRSA infection, which is of importance in orthopaedics, and has further benefits that may also be applied in other surgical specialties.


Assuntos
Infecção Hospitalar/prevenção & controle , Controle de Infecções/métodos , Resistência a Meticilina , Infecções Estafilocócicas/prevenção & controle , Staphylococcus aureus/efeitos dos fármacos , Estudos de Casos e Controles , Infecção Hospitalar/epidemiologia , Infecção Hospitalar/transmissão , Inglaterra/epidemiologia , Hospitais de Distrito , Hospitais Gerais , Humanos , Incidência , Ortopedia , Isolamento de Pacientes , Quartos de Pacientes , Infecções Estafilocócicas/epidemiologia , Infecções Estafilocócicas/transmissão
3.
J Bone Joint Surg Br ; 82(6): 885-8, 2000 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-10990317
4.
J Bone Joint Surg Br ; 74(1): 25-7, 1992 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-1732259

RESUMO

Failure of an acetabular cup is uncommon and has been attributed to wear or creep, trauma or bony irregularities in the acetabulum. We report ten cases in which fracture of the cup occurred at the site of drill holes used to anchor the marker wire. The role of such indentations as stress raisers has not been previously reported; we suggest that deep indentations or grooves should not be placed in the most highly stressed areas and that the cup thickness should allow for predicted wear rates.


Assuntos
Fios Ortopédicos , Prótese de Quadril , Acetábulo , Articulação do Quadril/diagnóstico por imagem , Humanos , Polietilenos , Desenho de Prótese , Falha de Prótese , Radiografia , Estresse Mecânico , Fatores de Tempo
7.
Acta Orthop Scand ; 62(1): 58-9, 1991 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-2003389

RESUMO

The loss of extension produced by tension-band wiring was studied using cadaveric elbows. Extension loss was found to be due to impingement of the longitudinal wires against the humerus independent of the tension band. Reducing the size of the bent end of the longitudinal wire is recommended, and bending the wire into a loop achieves this. In addition, passing the tension band through the loops prevents the wire from backing out.


Assuntos
Lesões no Cotovelo , Fixação de Fratura/métodos , Amplitude de Movimento Articular/fisiologia , Fraturas da Ulna/cirurgia , Fios Ortopédicos , Articulação do Cotovelo/fisiopatologia , Fixação de Fratura/instrumentação , Humanos , Fraturas da Ulna/fisiopatologia
8.
J R Coll Surg Edinb ; 36(3): 199-201, 1991 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-1920244

RESUMO

The completeness of data contained in a microcomputerized audit system has been compared with the operating theatre record book. The computerized audit system contained details of only 63% of the operations performed. Of the missing patients, 52% had never been completed. There were no failures of the computer system itself. Serious deficiencies in the methods of data entry were found and methods are described to overcome these deficits. The collection of audit information requires a disciplined approach and close supervision by a designated member of the surgical team.


Assuntos
Auditoria Médica/métodos , Sistemas de Informação em Salas Cirúrgicas/normas , Ortopedia/normas , Centro Cirúrgico Hospitalar/normas , Interpretação Estatística de Dados , Estudos de Avaliação como Assunto , Microcomputadores , Reino Unido
9.
Injury ; 22(2): 89-92, 1991 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-2037346

RESUMO

The introduction of the reconstruction nail has broadened the indications for the intramedullary fixation of difficult femoral fractures. The operative technique is, however, complicated. Some technical difficulties encountered during its use are presented, together with guidance to allow these problems to be avoided.


Assuntos
Pinos Ortopédicos , Fraturas do Fêmur/cirurgia , Fixação Intramedular de Fraturas/métodos , Adulto , Idoso , Neoplasias Ósseas/secundário , Neoplasias Ósseas/cirurgia , Feminino , Fraturas do Fêmur/diagnóstico por imagem , Fraturas do Colo Femoral/cirurgia , Fêmur/diagnóstico por imagem , Fêmur/cirurgia , Humanos , Masculino , Pessoa de Meia-Idade , Radiografia
10.
Injury ; 32(5): 383-9, 2001 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-11382423

RESUMO

Displaced distal radial fractures with extensive dorsal comminution and plastic cancellous deformation are unstable and frequently cause treatment problems since there is no single, reliable method of treatment, notably in osteoporotic bone. We present a method of holding unstable distal radial fractures with blunt ended K-wires via intrafocal and intramedullary insertion, so modifying the Kapandji technique. Wires were placed dorsally, radially and when necessary from the volar direction depending on fracture configuration. Over a 7-year period (1992-1999) we treated 102 patients with unstable distal radial fractures in this way. Of these, 80 were followed up for 6-42 weeks according to clinical need and scored radiologically and functionally using modified Lidstrom scoring system. Results showed that 92 and 95% of these patients achieved good or excellent results in these scoring systems, respectively. We present this as a useful and reliable method of treating these common fractures, particularly in osteoporotic bone.


Assuntos
Fios Ortopédicos , Fixação Intramedular de Fraturas/métodos , Fraturas Cominutivas/cirurgia , Fraturas do Rádio/cirurgia , Adolescente , Adulto , Idoso , Idoso de 80 Anos ou mais , Criança , Feminino , Fraturas Mal-Unidas/etiologia , Humanos , Masculino , Pessoa de Meia-Idade , Falha de Prótese , Resultado do Tratamento , Infecção dos Ferimentos/etiologia
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA