RESUMO
Diagnostic imaging is essential in the diagnosis and management, including surveillance, of known or suspected cancer in children. The independent and combined roles of the various modalities, consisting of radiography, fluoroscopy, ultrasonography (US), computed tomography (CT), magnetic resonance imaging (MRI), and nuclear medicine (NM), are both prescribed through protocols but also function in caring for complications that may occur during or subsequent to treatment such as infection, bleeding, or organ compromise. Use of a specific imaging modality may be based on situational circumstances such as a brain CT or MR for a new onset seizure, chest CT for respiratory signs or symptoms, or US for gross hematuria. However, in many situations, there are competing choices that do not easily lend themselves to a formulaic approach as options; these situations depend on the contributions of a variety of factors based on a combination of the clinical scenario and the strengths and limitations of the imaging modalities. Therefore, an improved understanding of the potential influence of the imaging decision pathways in pediatric cancer care can come from comparison among the individual diagnostic imaging modalities. The purpose of the following material to is to provide such a comparison. To do this, pediatric imaging content experts for the individual modalities of radiography and fluoroscopy, US, CT, MRI, and NM will discuss the individual modality strengths and limitations.
Assuntos
Neoplasias , Ressonância de Plasmônio de Superfície , Humanos , Criança , Neoplasias/diagnóstico por imagem , Tomografia Computadorizada por Raios X , Oncologia , Cintilografia , Imageamento por Ressonância Magnética/métodosRESUMO
Over the last decade, health care professionals in the field of radiology have experienced increasing rates of burnout. A study in 2017 showed high prevalence of burnout in pediatric radiology, and other studies have identified several drivers for burnout. An important factor in promoting wellness and mitigating burnout is leveraging diversity, equity and inclusion in the workplace. This manuscript highlights the importance of diversity in high-functioning teams as well as the critical role of equity and inclusion in the workplace to help create an organization where people belong and can effectively succeed.
Assuntos
Esgotamento Profissional , Promoção da Saúde , Radiologia , Engajamento no Trabalho , Esgotamento Profissional/prevenção & controle , Criança , Humanos , Pediatria , Radiografia , Salários e Benefícios , Local de TrabalhoRESUMO
BACKGROUND: Non-alcoholic fatty liver disease (NAFLD) is increasing in prevalence and is the most common cause of pediatric chronic liver disease. Objective US-based measures of hepatic steatosis are an unmet clinical need. OBJECTIVE: To evaluate the diagnostic performance of quantitative measurement of liver echogenicity (hepatorenal index, or HRI) for hepatic steatosis in a pediatric cohort. MATERIALS AND METHODS: We identified pediatric patients (≤18 years old) who underwent both clinically indicated abdominal US and MRI with liver proton-density fat fraction (PDFF) within the 3-month period during the timeframe of July 2015-April 2020 (n=69). Using ImageJ, we drew small circular regions of interest (ROIs) and large freehand ROIs in the liver and right kidney on single longitudinal and transverse images to measure echogenicity (arbitrary units). We calculated four HRIs (liver-to-kidney ratio) as well as liver histogram features. Five pediatric radiologists independently reported the qualitative presence/absence of hepatic steatosis. We used Pearson correlation (r) to assess associations and receiver operating characteristic (ROC) curve analyses to evaluate diagnostic performance. Multivariable logistic regression was used to further assess relationships. RESULTS: Mean patient age was 11.6 (standard deviation [SD] 4.7, range 0.3-18) years; 27/69 (39.1%) were female. Mean PDFF was 12.5% (SD 13.1%, range 1-48%); 34/69 (49.3%) patients were classified as having hepatic steatosis by MRI (PDFF ≥6%). There were significant, positive correlations between all four US HRI methods and PDFF (r=0.51-0.61); longitudinal freehand ROIs exhibited the strongest correlation (r=0.61; P<0.0001). Longitudinal freehand ROI HRI had moderate diagnostic performance for the binary presence of steatosis (area under the curve [AUC]=0.80, P<0.0001), with an optimal cut-off value >1.75 (sensitivity=70.6%, specificity=77.1%). Radiologists' sensitivity for detecting hepatic steatosis ranged from 79.4% to 97.1%, and specificity ranged from 91.2% to 100%. Significant multivariable predictors of PDFF ≥6% included HRI (P=0.002; odds ratio [OR]=34.2), body mass index (BMI) percentile (P=0.005; OR=1.06), and liver gray-scale echogenicity standard deviation (P=0.02; OR=0.79) (receiver operating characteristic AUC = 0.92). CONCLUSION: Quantitative US HRI has moderate diagnostic performance for detecting liver fat in children and positively correlates with MRI PDFF. Incorporation of BMI-percentile and gray-scale echogenicity standard deviation improved diagnostic performance.
Assuntos
Fígado , Hepatopatia Gordurosa não Alcoólica , Adolescente , Criança , Pré-Escolar , Feminino , Humanos , Lactente , Fígado/diagnóstico por imagem , Imageamento por Ressonância Magnética/métodos , Masculino , Curva ROC , Ultrassonografia/métodosRESUMO
Ultrasonography (US) is the first-line imaging modality for screening neonates and young infants with suspected spinal abnormalities. Whether performed for a suspicious congenital skin lesion, such as a lumbosacral tract or lipomatous mass, or abnormal neurological findings, US can help define spinal anatomy, characterize congenital spine malformations, and direct further work-up and management. The purpose of this article is to review the diagnostic imaging approach to infant spine US, including technique and indications, normal anatomy and variants with a focus on embryological origins, and classification and diagnosis of congenital spine malformations.
Assuntos
Lipoma , Imageamento por Ressonância Magnética , Humanos , Lactente , Recém-Nascido , Coluna Vertebral/diagnóstico por imagem , UltrassonografiaRESUMO
There is increasing emphasis on improving the patient experience with a shift to patient- and family-centered care throughout all areas of health care. In 2013, the American College of Radiology launched Imaging 3.0, an initiative aimed at encouraging and enabling radiologists to work on culture change to increase focus on appropriateness, efficiency, quality, safety and patient satisfaction. Many groups have subsequently used these and other tools to improve the overall patient experience, focusing on the entire imaging journey to include initial order placement, registration in the department, image acquisition, departure from the department, and how and when the patient and family receive the imaging results. In our department we have used multiple strategies and have applied quality-improvement methods and patient/family-centered care models to improve quality, safety and the patient experience. Most of these efforts have included team members across the department, including radiologists, technologists, quality-improvement personnel, managers and nurses. In addition, for the last 12 years, a key member of these teams has been our patient and family advocate (PFA). We describe the important role that a PFA can play in improving the patient and family experience in pediatric radiology.
Assuntos
Defesa do Paciente , Assistência Centrada no Paciente , Relações Médico-Paciente , Relações Profissional-Família , Serviço Hospitalar de Radiologia/organização & administração , Criança , Humanos , Cultura Organizacional , Objetivos Organizacionais , Satisfação do Paciente , Melhoria de QualidadeRESUMO
The Beyond Ultrasound First Forum was conceived to increase awareness that the quality of obstetric and gynecologic ultrasound can be improved, and is inconsistent throughout the country, likely due to multiple factors, including the lack of a standardized curriculum and competency assessment in ultrasound teaching. The forum brought together representatives from many professional associations; the imaging community including radiology, obstetrics and gynecology, and emergency medicine among others; in addition to government agencies, insurers, industry, and others with common interest in obstetric and gynecologic ultrasound. This group worked together in focus sessions aimed at developing solutions on how to standardize and improve ultrasound training at the resident level and beyond. A new curriculum and competency assessment program for teaching residents (obstetrics and gynecology, radiology, and any other specialty doing obstetrics and gynecology ultrasound) was presented, and performance measures of ultrasound quality in clinical practice were discussed. The aim of this forum was to increase and unify the quality of ultrasound examinations in obstetrics and gynecology with the ultimate goal of improving patient safety and quality of clinical care. This report describes the proceedings of this conference including possible approaches to resident teaching and means to improve the inconsistent quality of ultrasound examinations performed today.
Assuntos
Competência Clínica , Internato e Residência , Obstetrícia/educação , Garantia da Qualidade dos Cuidados de Saúde , Melhoria de Qualidade , Ultrassonografia Pré-Natal , Acreditação , Feminino , Humanos , Gravidez , Estados UnidosRESUMO
The Beyond Ultrasound First Forum was conceived to increase awareness that the quality of obstetric and gynecologic ultrasound can be improved, and is inconsistent throughout the country, likely due to multiple factors, including the lack of a standardized curriculum and competency assessment in ultrasound teaching. The forum brought together representatives from many professional associations; the imaging community including radiology, obstetrics and gynecology, and emergency medicine among others; in addition to government agencies, insurers, industry, and others with common interest in obstetric and gynecologic ultrasound. This group worked together in focus sessions aimed at developing solutions on how to standardize and improve ultrasound training at the resident level and beyond. A new curriculum and competency assessment program for teaching residents (obstetrics and gynecology, radiology, and any other specialty doing obstetrics and gynecology ultrasound) was presented, and performance measures of ultrasound quality in clinical practice were discussed. The aim of this forum was to increase and unify the quality of ultrasound examinations in obstetrics and gynecology with the ultimate goal of improving patient safety and quality of clinical care. This report describes the proceedings of this conference including possible approaches to resident teaching and means to improve the inconsistent quality of ultrasound examinations performed today.
Assuntos
Competência Clínica/normas , Ginecologia/educação , Obstetrícia/educação , Melhoria de Qualidade , Ultrassom/educação , Ultrassonografia Pré-Natal/normas , Currículo/normas , Feminino , Humanos , Gravidez , Estados UnidosRESUMO
The incidence of primary (i.e. essential) hypertension in children and adolescents is increasing; however, secondary hypertension, with an identifiable cause, remains relatively common and might be treatable or even curable. Renovascular hypertension is an uncommon but important secondary cause of hypertension in the pediatric population that can be associated with substantial morbidity. In this article we discuss renin-mediated causes of hypertension in children and related complications, review renal Doppler ultrasound techniques for the evaluation of renin-mediated hypertension (including both direct and indirect assessments), and briefly appraise the literature pertaining to renal Doppler ultrasound and the assessment of pediatric hypertension. Finally, we describe a proposed role for renal Doppler ultrasound in the workup of suspected renin-mediated hypertension in children and adolescents.
Assuntos
Hipertensão Renovascular/diagnóstico por imagem , Hipertensão Renovascular/fisiopatologia , Sistema Renina-Angiotensina/fisiologia , Ultrassonografia Doppler/métodos , Adolescente , Criança , Pré-Escolar , Humanos , Lactente , Recém-NascidoRESUMO
Recent political and economic factors have contributed to a meaningful change in the way that quality in health care, and by extension value, are viewed. While quality is often evaluated on the basis of subjective criteria, pay-for-performance programs that link reimbursement to various measures of quality require use of objective and quantifiable measures. This evolution to value-based payment was accelerated by the 2015 passage of the Medicare Access and CHIP (Children's Health Insurance Program) Reauthorization Act (MACRA). While many of the drivers of these changes are rooted in federal policy and programs such as Medicare and aimed at adult patients, the practice of pediatrics and pediatric radiology will be increasingly impacted. This article addresses issues related to the use of quantitative measures to evaluate the quality of services provided by the pediatric radiology department or sub-specialty section, particularly as seen from the viewpoint of a payer that may be considering ways to link payment to performance. The paper concludes by suggesting a metric categorization strategy to frame future work on the subject.
Assuntos
Pediatria/economia , Pediatria/normas , Qualidade da Assistência à Saúde/economia , Radiologia/economia , Radiologia/normas , Reembolso de Incentivo/economia , Seguro de Saúde Baseado em Valor/economia , Humanos , Medicare Access and CHIP Reauthorization Act of 2015 , Mecanismo de Reembolso , Estados UnidosRESUMO
OBJECTIVE: To determine the interrater reliability (IRR) of lung ultrasonography (LUS) and chest radiography (CXR) and evaluate the accuracy of LUS compared with CXR for detecting pediatric pneumonia compared with chest computed tomography (CT) scan. STUDY DESIGN: This was a prospective cohort study of children aged 3 months to 18 years with a CXR and LUS performed between May 1, 2012, and January 31, 2014 with or without a clinical diagnosis of pneumonia. Four pediatric radiologists blinded to clinical information reported findings for the CXR and LUS images. IRR was estimated for 50 LUS and CXR images. The main outcome was the finding from CT ordered clinically or the probability of the CT finding for patients clinically requiring CT. Two radiologists reviewed CT scans to determine an overall finding. Latent class analysis was used to evaluate the sensitivity and specificity for findings (eg, consolidation) for LUS and CXR compared with CT. RESULTS: Of the 132 patients in the cohort, 36 (27%) had CT performed for a clinical reason. Pneumonia was clinically documented in 47 patients (36%). The IRR for lung consolidation was 0.55 (95% CI, 0.40-0.70) for LUS and 0.36 (95% CI, 0.21-0.51) for CXR. The sensitivity for detecting consolidation, interstitial disease, and pleural effusion was statistically similar for LUS and CXR compared with CT; however, specificity was higher for CXR. The negative predictive value was similar for CXR and LUS. CONCLUSIONS: LUS has a sufficiently high IRR for detection of consolidation. Compared with CT, LUS and CXR have similar sensitivity, but CXR is more specific for findings indicating pneumonia.
Assuntos
Pneumonia/diagnóstico por imagem , Radiografia Torácica/normas , Ultrassonografia/normas , Adolescente , Criança , Pré-Escolar , Feminino , Humanos , Lactente , Masculino , Variações Dependentes do Observador , Estudos Prospectivos , Reprodutibilidade dos Testes , Tomografia Computadorizada por Raios XRESUMO
OBJECTIVES: To quantify rates and variation in emergency department (ED) cranial computed tomography (CT) utilization in children with ventricular shunts, estimate radiation exposure, and evaluate the association between CT utilization and shunt revision. STUDY DESIGN: Retrospective longitudinal cohort study of ED visits from 2003-2013 in children 0-18 years old with initial shunt placement in 2003. Data were examined from 31 hospitals in the Pediatric Health Information System. Main outcomes were cranial CT performed during an ED visit, estimated cumulative effective radiation dose, and shunt revision within 7 days. Multivariable regression modeled the relationship between patient- and hospital-level covariates and CT utilization. RESULTS: The 1319 children with initial shunt placed in 2003 experienced 6636 ED visits during the subsequent decade. A cranial CT was obtained in 49.4% of all ED visits; 19.9% of ED visits with CT were associated with a shunt revision. Approximately 6% of patients received ≥10 CTs, accounting for 37.2% of all ED visits with a CT. The mean number of CTs per patient varied nearly 20-fold across hospitals; the individual hospital accounted for the most variation in CT utilization. The median (IQR) cumulative effective radiation dose was 7.2 millisieverts (3.6-14.0) overall, and 33.4 millisieverts (27.2-43.8) among patients receiving ≥10 CTs. CONCLUSIONS: A CT scan was obtained in half of ED visits for children with a ventricular shunt, with wide variability in utilization by hospitals. Strategies are needed to identify children at risk of shunt malfunction to reduce variability in CT utilization and radiation exposure in the ED.
Assuntos
Derivações do Líquido Cefalorraquidiano/métodos , Serviço Hospitalar de Emergência/estatística & dados numéricos , Hidrocefalia/cirurgia , Tomografia Computadorizada por Raios X/estatística & dados numéricos , Adolescente , Criança , Pré-Escolar , Feminino , Seguimentos , Humanos , Hidrocefalia/diagnóstico por imagem , Lactente , Recém-Nascido , Masculino , Estudos RetrospectivosRESUMO
Overexpression of GALGT2 in skeletal muscle can stimulate the glycosylation of α dystroglycan and the upregulation of normally synaptic dystroglycan-binding proteins, some of which are dystrophin and laminin α2 surrogates known to be therapeutic for several forms of muscular dystrophy. This article describes the vascular delivery of GALGT2 gene therapy in a large animal model, the rhesus macaque. Recombinant adeno-associated virus, rhesus serotype 74 (rAAVrh74), was used to deliver GALGT2 via the femoral artery to the gastrocnemius muscle using an isolated focal limb perfusion method. GALGT2 expression averaged 44 ± 4% of myofibers after treatment in macaques with low preexisting anti-rAAVrh74 serum antibodies, and expression was reduced to 9 ± 4% of myofibers in macaques with high preexisting rAAVrh74 immunity (P < 0.001; n = 12 per group). This was the case regardless of the addition of immunosuppressants, including prednisolone, tacrolimus, and mycophenolate mofetil. GALGT2-treated macaque muscles showed increased glycosylation of α dystroglycan and increased expression of dystrophin and laminin α2 surrogate proteins, including utrophin, plectin1, agrin, and laminin α5. These experiments demonstrate successful transduction of rhesus macaque muscle with rAAVrh74.MCK.GALGT2 after vascular delivery and induction of molecular changes thought to be therapeutic in several forms of muscular dystrophy.