Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Mais filtros

Base de dados
Ano de publicação
Tipo de documento
País de afiliação
Intervalo de ano de publicação
1.
J Sports Sci ; 37(16): 1910-1918, 2019 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-31012798

RESUMO

This study aimed to validate the Sedentary Sphere posture classification method from wrist-worn accelerometers in children. Twenty-seven 9-10-year-old children wore ActiGraph GT9X (AG) and GENEActiv (GA) accelerometers on both wrists, and activPAL on the thigh while completing prescribed activities: five sedentary activities, standing with a phone, walking (criterion for all 7: observation) and 10-min free-living play (criterion: activPAL). In an independent sample, 21 children wore AG and GA accelerometers on the non-dominant wrist and activPAL for two days of free-living. Per cent accuracy, pairwise 95% equivalence tests (±10% equivalence zone) and intra-class correlation coefficients (ICC) analyses were completed. Accuracy was similar, for prescribed activities irrespective of brand (non-dominant wrist: 77-78%; dominant wrist: 79%). Posture estimates were equivalent between wrists within brand (±6%, ICC > 0.81, lower 95% CI ≥ 0.75), between brands worn on the same wrist (±5%, ICC ≥ 0.84, lower 95% CI ≥ 0.80) and between brands worn on opposing wrists (±6%, ICC ≥ 0.78, lower 95% CI ≥ 0.72). Agreement with activPAL during free-living was 77%, but sedentary time was underestimated by 7% (GA) and 10% (AG). The Sedentary Sphere can be used to classify posture from wrist-worn AG and GA accelerometers for group-level estimates in children, but future work is needed to improve the algorithm for better individual-level results.


Assuntos
Actigrafia/instrumentação , Monitores de Aptidão Física , Postura , Comportamento Sedentário , Atividades Cotidianas , Algoritmos , Criança , Desenho de Equipamento , Feminino , Humanos , Masculino , Reprodutibilidade dos Testes , Coxa da Perna , Punho
2.
Children (Basel) ; 5(12)2018 Dec 19.
Artigo em Inglês | MEDLINE | ID: mdl-30572683

RESUMO

This study aimed to: (1) compare acceleration output between ActiGraph (AG) hip and wrist monitors and GENEActiv (GA) wrist monitors; (2) identify raw acceleration sedentary and stationary thresholds for the two brands and placements; and (3) validate the thresholds during a free-living period. Twenty-seven from 9- to 10-year-old children wore AG accelerometers on the right hip, dominant- and non-dominant wrists, GA accelerometers on both wrists, and an activPAL on the thigh, while completing seven sedentary and light-intensity physical activities, followed by 10 minutes of school recess. In a subsequent study, 21 children wore AG and GA wrist monitors and activPAL for two days of free-living. The main effects of activity and brand and a significant activity × brand × placement interaction were observed (all p < 0.0001). Output from the AG hip was lower than the AG wrist monitors (both p < 0.0001). Receiver operating characteristic (ROC) curves established AG sedentary thresholds of 32.6 mg for the hip, 55.6 mg and 48.1 mg for dominant and non-dominant wrists respectively. GA wrist thresholds were 56.5 mg (dominant) and 51.6 mg (non-dominant). Similar thresholds were observed for stationary behaviours. The AG non-dominant threshold came closest to achieving equivalency with activPAL during free-living.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA