Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 185
Filtrar
Mais filtros

Base de dados
País/Região como assunto
Tipo de documento
Intervalo de ano de publicação
1.
Eur Radiol ; 34(10): 6407-6415, 2024 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-38512491

RESUMO

OBJECTIVE: To retrospectively evaluate the long-term outcomes after percutaneous cryoablation of abdominal wall endometriosis (AWE). METHOD: The Institutional Review Board approved this retrospective observational review of 40 consecutive patients, of a median age of 37 years (interquartile range [IQR] 32-40 years), presenting with a total of 52 symptomatic AWE nodules. All patients underwent cryoablation between January 2013 and May 2022 with a minimum follow-up period of 12 months. Outcomes were assessed using a visual analog scale (VAS) that measured pain, as well as by magnetic resonance imaging (MRI). The pain-free survival rates were derived using the Kaplan-Meier estimator. Adverse events were analyzed and graded using the classification system of the Cardiovascular and Interventional Radiological Society of Europe. RESULTS: The median follow-up time was 40.5 months (IQR 26.5-47.2 months). The median VAS score before cryoablation was 8 (IQR 7-9). Complete relief of symptoms was documented in 80% (32/40) of patients at 3 months after initial cryoablation and correlated with the absence of residual endometriosis nodules on MRI. The median pain-free survival rates were 89.2% [95% CI, 70.1-96.4%] at 36 months and 76.8% [95% CI, 55.3-83.8%] after 60 months. No patient or lesion characteristics were found to be prognostic of failure. No major adverse events or side effects were reported in long term. CONCLUSION: Cryoablation safely and effectively afforded long-term pain relief for patients with AWE nodules. CLINICAL RELEVANCE STATEMENT: AWE cryoablation was found to be safe and effective in the long-term. KEY POINTS: • Cryoablation is highly effective with 80% of patients experiencing complete relief of AWE symptoms after a single procedure. • Cryoablation is safe without long-term adverse events or side effects. • The median pain-free survival rates are 89.2% at 36 months and 76.8% at 60 months.


Assuntos
Parede Abdominal , Criocirurgia , Endometriose , Humanos , Endometriose/cirurgia , Endometriose/diagnóstico por imagem , Feminino , Criocirurgia/métodos , Adulto , Estudos Retrospectivos , Resultado do Tratamento , Parede Abdominal/cirurgia , Parede Abdominal/diagnóstico por imagem , Imageamento por Ressonância Magnética/métodos , Medição da Dor
2.
J Vasc Interv Radiol ; 35(3): 409-415, 2024 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-38008376

RESUMO

PURPOSE: To evaluate the impact of virtual injection software (VIS) use during cone-beam computed tomography (CT)-guided prostatic artery embolization (PAE) on both patient radiation exposure and procedural time. MATERIALS AND METHODS: This institutional review board (IRB)-approved comparative retrospective study analyzed the treatment at a single institution of 131 consecutive patients from January 2020 to May 2022. Cone-beam CT was used with (Group 1, 77/131; 58.8%) or without VIS (Group 2, 54/131, 41.2%). Radiation exposure (number of digital subtraction angiography [DSA] procedures), dose area product (DAP), total air kerma (AK), peak skin dose (PSD), fluoroscopy time (FT), and procedure time (PT) were recorded. The influences of age, body mass index, radial access, and use of VIS were assessed. RESULTS: In bivariate analysis, VIS use (Group 1) showed reduction in the number of DSA procedures (8.6 ± 3.7 vs 16.8 ± 4.3; P < .001), DAP (110.4 Gy·cm2 ± 46.8 vs 140.5 Gy·cm2 ± 61; P < .01), AK (642 mGy ± 451 vs 1,150 mGy ± 637; P = .01), PSD (358 mGy ± 251 vs 860 mGy ± 510; P = .001), FT (35.6 minutes ± 15.4 vs 46.6 minutes ± 20; P = .001), and PT (94.6 minutes ± 41.3 vs 115.2 minutes ± 39.6, P = .005) compared to those in Group 2. In multivariate analysis, AK, PSD, FT, and PT reductions were associated with VIS use (P < .001, P < .001, P = .001, and P = .006, respectively). CONCLUSIONS: The use of VIS during PAE performed under cone-beam CT guidance led to significant reduction in patient radiation exposure and procedural time.


Assuntos
Embolização Terapêutica , Hiperplasia Prostática , Exposição à Radiação , Masculino , Humanos , Embolização Terapêutica/efeitos adversos , Próstata/diagnóstico por imagem , Próstata/irrigação sanguínea , Estudos Retrospectivos , Hiperplasia Prostática/terapia , Artérias/diagnóstico por imagem , Exposição à Radiação/efeitos adversos , Exposição à Radiação/prevenção & controle , Software , Tomografia Computadorizada de Feixe Cônico/efeitos adversos , Tomografia Computadorizada de Feixe Cônico/métodos , Doses de Radiação , Fluoroscopia
3.
J Vasc Interv Radiol ; 35(6): 859-864, 2024 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-38447771

RESUMO

PURPOSE: To compare the effectiveness of percutaneous lung biopsy using a patient-mounted needle-driving robotic system with that using a manual insertion of needles under computed tomography (CT) fluoroscopy guidance. MATERIALS AND METHODS: In this institutional review board approved study, the cohort consisted of a series of patients who underwent lung biopsies following the intention-to-treat protocol from September 2022 to September 2023 using robot (n = 15) or manual insertion under single-rotation CT fluoroscopy (n = 66). Patient and procedure characteristics were recorded as well as outcomes. RESULTS: Although age, body mass index, and skin-to-target distance were not statistically different, target size varied (median, 8 mm [interquartile range, 6.5-9.5 mm] for robot vs 12 mm [8-18 mm] for single-rotation CT fluoroscopy; P = .001). No statistical differences were observed in technical success (86.7% [13/15] vs 89.4% [59/66], P = .673), Grade 3 adverse event (AE) (6.7% [1/15] vs 12.1% [8/66], P = .298), procedural time (28 minutes [22-32 minutes] vs 19 minutes [14.3-30.5 minutes], P = .086), and patient radiation dose (3.9 mSv [3.2-5.6 mSv] vs 4.6 mSv [3.3-7.5 mSv], P = .398). In robot-assisted cases, the median angle out of gantry plane was 10° (6.5°-16°), although it was null (0°-5°) for single-rotation CT fluoroscopy (P = .001). CONCLUSIONS: Robot-assisted and single-rotation CT fluoroscopy-guided percutaneous lung biopsies were similar in terms of technical success, diagnostic yield, procedural time, AEs, and radiation dose, although robot allowed for out-of-gantry plane navigation along the needle axis.


Assuntos
Biópsia Guiada por Imagem , Pulmão , Radiografia Intervencionista , Procedimentos Cirúrgicos Robóticos , Tomografia Computadorizada por Raios X , Humanos , Masculino , Feminino , Fluoroscopia , Pessoa de Meia-Idade , Biópsia Guiada por Imagem/efeitos adversos , Biópsia Guiada por Imagem/instrumentação , Idoso , Estudos Retrospectivos , Procedimentos Cirúrgicos Robóticos/instrumentação , Pulmão/diagnóstico por imagem , Pulmão/patologia , Biópsia por Agulha/efeitos adversos , Biópsia por Agulha/instrumentação , Valor Preditivo dos Testes , Agulhas , Desenho de Equipamento , Fatores de Tempo
4.
J Vasc Interv Radiol ; 2024 Aug 12.
Artigo em Inglês | MEDLINE | ID: mdl-39142517

RESUMO

PURPOSE: To evaluate the safety and effectiveness of lateral or posterolateral percutaneous vertebroplasty (PVP) of osteolytic C1-C2 lesions performed under computed tomography (CT) guidance and local anesthesia. MATERIALS AND METHODS: A retrospective study of 16 consecutive patients (11 females and 5 males; aged from 24 to 86 years; median age, 65.5 years) who underwent 17 lateral or posterolateral PVP was performed. Pain status was assessed using a visual analog scale (VAS). Patients were evaluated preoperatively as baseline and at 24 hours and 1, 6, and 12 months postoperatively, until death, or until loss to follow-up. The Oswestry Disability Index was used to evaluate the patients' functional disability preoperatively. The adverse events were recorded using the Society of Interventional Radiology (SIR) classification. RESULTS: The technical success was 100% (17/17) for a median Spinal Instability Neoplastic Score of 13.5 (interquartile range [IQR], 6.8, 20.3). Mean clinical follow-up was 10.1 months (range, 6-36 months; median, 19.5 months, IQR, 4, 35 months). Mean VAS score decreased significantly from 7.5 (SD ± 2.1) preoperatively to 1.6 (SD ± 1.5) 24 hours postoperatively, and 1.0 (SD ± 1.1), 1.5 (SD ± 1.0), and 0.5 (SD ± 1.5) at 1, 6, and 12 months, respectively (all P < .001). No severe adverse events were observed, but 3 cases of asymptomatic cement leakage were noted (SIR Grade 1; 17.6% [3/17]). CONCLUSIONS: Lateral and posterolateral PVP performed under CT guidance and local anesthesia is safe and effective to treat symptomatic osteolytic C1-C2 lesions.

5.
Int J Hyperthermia ; 41(1): 2313492, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-38369302

RESUMO

BACKGROUND: Despite the theoretical advantages of treating metastatic bone disease with microwave ablation (MWA), there are few reports characterizing microwave absorption and bioheat transfer in bone. This report describes a computational modeling-based approach to simulate directional microwave ablation (dMWA) in spine, supported by ex vivo and pilot in vivo experiments in porcine vertebral bodies. MATERIALS AND METHODS: A 3D computational model of microwave ablation within porcine vertebral bodies was developed. Ex vivo porcine vertebra experiments using a dMWA applicator measured temperatures approximately 10.1 mm radially from the applicator in the direction of MW radiation (T1) and approximately 2.4 mm in the contra-lateral direction (T2). Histologic assessment of ablated ex vivo tissue was conducted and experimental results compared to simulations. Pilot in vivo experiments in porcine vertebral bodies assessed ablation zones histologically and with CT and MRI. RESULTS: Experimental T1 and T2 temperatures were within 3-7% and 11-33% of simulated temperature values. Visible ablation zones, as indicated by grayed tissue, were smaller than those typical in other soft tissues. Posthumous MRI images of in vivo ablations showed hyperintensity. In vivo experiments illustrated the technical feasibility of creating directional microwave ablation zones in porcine vertebral body. CONCLUSION: Computational models and experimental studies illustrate the feasibility of controlled dMWA in bone tissue.


Assuntos
Técnicas de Ablação , Ablação por Cateter , Ablação por Radiofrequência , Suínos , Animais , Técnicas de Ablação/métodos , Micro-Ondas/uso terapêutico , Simulação por Computador , Coluna Vertebral/cirurgia , Fígado/cirurgia , Ablação por Cateter/métodos
6.
J Minim Invasive Gynecol ; 31(9): 726-737.e2, 2024 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-38901689

RESUMO

OBJECTIVE: Despite various surgical and nonsurgical strategies for abdominal wall endometriosis, the lack of definitive guidance on optimal treatment choice leads to clinical uncertainty. This review scrutinizes the safety and efficacy of abdominal wall endometriosis treatments to aid in decision-making. DATA SOURCES: We performed a systematic literature review of PubMed, Embase, and Cochrane Library databases from 1947 until December 2023. METHODS OF STUDY SELECTION: A comprehensive literature search identified studies that assessed both surgical and nonsurgical interventions, including high-intensity focused ultrasound (HIFU), cryoablation, radiofrequency ablation, and microwave ablation. This review is registered in NIHR-PROSPERO (CRD 42023494969). Local tumor control (LTC), local pain relief (LPR), and adverse events (AE) were recorded. TABULATION, INTEGRATION, AND RESULTS: This review included 51 articles among 831 identified. All study designs were considered eligible for inclusion. A total of 2674 patients are included: 2219 patients (83%) undergoing surgery, and 455 (17%) undergoing percutaneous interventions (342 HIFU, 103 cryoablation, 1 radiofrequency ablation, 9 microwave ablation). Follow-up length was 18 months in median, ranging from 1 to 235 months. Overall LTC rates ranged from 86% to 100%. Surgical interventions consistently demonstrated the highest rate of LTC with a median rate of 100%, and LPR with a median rate of 98.2% (95% confidence interval [CI]: 93.9-97.7). HIFU showed median LTC and LPR rates, respectively of 95.65% (95% CI, 87.7-99.9) and 76.1% (95% CI, 61.8-90.4); and cryoablation of 85.7% (95% CI, 66.0-99.9) and 79.2% (95% CI, 67.4-91.03). Minor AE was reported after surgery in 17.5% of patients (225/1284) including 15.9% (199/1284) of mesh implantation; 76.4% (239/313) after HIFU; and 8.7% (9/103) after cryoablation. Severe AE was reported in 25 patients in the surgery group and 1 in the percutaneous group. CONCLUSION: The safety profile and efficacy of nonsurgical interventions support their clinical utility for management of abdominal wall endometriosis.


Assuntos
Parede Abdominal , Endometriose , Feminino , Humanos , Parede Abdominal/cirurgia , Criocirurgia/efeitos adversos , Criocirurgia/métodos , Endometriose/terapia , Ablação por Ultrassom Focalizado de Alta Intensidade/efeitos adversos , Ablação por Ultrassom Focalizado de Alta Intensidade/métodos , Cirurgia Assistida por Computador/efeitos adversos , Cirurgia Assistida por Computador/métodos
7.
Genes Chromosomes Cancer ; 62(4): 210-222, 2023 04.
Artigo em Inglês | MEDLINE | ID: mdl-36502525

RESUMO

Only a few patients with germline AXIN2 variants and colorectal adenomatous polyposis or cancer have been described, raising questions about the actual contribution of this gene to colorectal cancer (CRC) susceptibility. To assess the clinical relevance for AXIN2 testing in patients suspected of genetic predisposition to CRC, we collected clinical and molecular data from the French Oncogenetics laboratories analyzing AXIN2 in this context. Between 2004 and June 2020, 10 different pathogenic/likely pathogenic AXIN2 variants were identified in 11 unrelated individuals. Eight variants were from a consecutive series of 3322 patients, which represents a frequency of 0.24%. However, loss-of-function AXIN2 variants were strongly associated with genetic predisposition to CRC as compared with controls (odds ratio: 11.89, 95% confidence interval: 5.103-28.93). Most of the variants were predicted to produce an AXIN2 protein devoid of the SMAD3-binding and DIX domains, but preserving the ß-catenin-binding domain. Ninety-one percent of the AXIN2 variant carriers who underwent colonoscopy had adenomatous polyposis. Forty percent of the variant carriers developed colorectal or/and other digestive cancer. Multiple tooth agenesis was present in at least 60% of them. Our report provides further evidence for a role of AXIN2 in CRC susceptibility, arguing for AXIN2 testing in patients with colorectal adenomatous polyposis or cancer.


Assuntos
Polipose Adenomatosa do Colo , Neoplasias Colorretais , Humanos , Predisposição Genética para Doença , Polipose Adenomatosa do Colo/genética , Polipose Adenomatosa do Colo/patologia , Mutação em Linhagem Germinativa , beta Catenina/metabolismo , Células Germinativas/metabolismo , Neoplasias Colorretais/genética , Neoplasias Colorretais/patologia , Proteína Axina/genética
8.
Can Assoc Radiol J ; : 8465371241290076, 2024 Oct 12.
Artigo em Inglês | MEDLINE | ID: mdl-39394918

RESUMO

In tandem with the ever-increasing global population, the demand for diagnostic radiology service provision is on the rise and at a disproportionate rate compared to the number of radiologists available to practice. The current "revolution in robotics" promises to alleviate personnel shortages in many sectors of industry, including medicine. Despite negative depictions of robots in popular culture, their multiple potential benefits cannot be overlooked, in particular when it comes to health service provision. The type of robots used for interventional procedures are largely robotic-assistance devices, such as the Da Vinci surgical robot. Advances have also been made with regards to robots for image-guided percutaneous needle placement, which have demonstrated superior accuracy compared to manual methods. It is likely that artificial intelligence will come to play a key role in the field of robotics and will result in an increase in the levels of robotic autonomy attainable. However, this concept is not without ethical and legal considerations, most notably who is responsible should an error occur; the physician, the robot manufacturer, software engineers, or the robot itself? Efforts have been made to legislate in order to protect against the potentially harmful effects of unexplainable "black-box" decision outputs of artificial intelligence systems. In order to be accepted by patients, studies have shown that the perceived level of trustworthiness and predictability of robots is crucial. Ultimately, effective, widespread implementation of medical robotic systems will be contingent on developers remaining cognizant of factors that increase human acceptance, as well as ensuring compliance with regulations.

9.
Can Assoc Radiol J ; 75(4): 907-920, 2024 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-38581355

RESUMO

Objectives: This systematic review aims to assess existing research concerning the use of robotic systems to execute percutaneous lung biopsy. Methods: A systematic review was performed and identified 4 studies involving robotic systems used for lung biopsy. Outcomes assessed were operation time, radiation dose to patients and operators, technical success rate, diagnostic yield, and complication rate. Results: One hundred and thirteen robot-guided percutaneous lung biopsies were included. Technical success and diagnostic yield were close to 100%, comparable to manual procedures. Technical accuracy, illustrated by needle positioning, showed less frequent needle adjustments in robotic guidance than in manual guidance (P < .001): 2.7 ± 2.6 (range 1-4) versus 6 ± 4 (range 2-12). Procedure time ranged from comparable to reduced by 35% on average (20.1 ± 11.3 minutes vs 31.4 ± 10.2 minutes, P = .001) compared to manual procedures. Patient irradiation ranged from comparable to reduced by an average of 40% (324 ± 114.5 mGy vs 541.2 ± 446.8 mGy, P = .001). There was no significant difference in reported complications between manual biopsy and biopsies that utilized robotic guidance. Conclusion: Robotic systems demonstrate promising results for percutaneous lung biopsy. These devices provide adequate accuracy in probe placement and could both reduce procedural duration and mitigate radiation exposure to patients and practitioners. However, this review underscores the need for larger, controlled trials to validate and extend these findings.


Assuntos
Biópsia Guiada por Imagem , Pulmão , Procedimentos Cirúrgicos Robóticos , Humanos , Biópsia por Agulha/métodos , Biópsia por Agulha/instrumentação , Biópsia Guiada por Imagem/métodos , Biópsia Guiada por Imagem/instrumentação , Pulmão/diagnóstico por imagem , Pulmão/patologia , Pneumopatias/patologia , Neoplasias Pulmonares/patologia , Neoplasias Pulmonares/diagnóstico por imagem , Procedimentos Cirúrgicos Robóticos/instrumentação , Procedimentos Cirúrgicos Robóticos/métodos
10.
Can Assoc Radiol J ; 75(3): 644-648, 2024 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-38311875

RESUMO

OBJECTIVES: To prospectively evaluate the feasibility and safety of a polyetheretherketone (PEEK) polymer transpedicular vertebral system to treat vertebral compression fracture (VCF). METHODS: Nine consecutive patients (4 men and 5 women; median age 59 [interquartile range: 58-64 years]) were included. The procedure duration, length of hospital stay, and complications were reported. Visual analog scale (VAS) and the Oswestry disability index (ODI) for pain and disability were assessed before and at 2, 6, and 12-month after the procedure. RESULTS: The procedure was technically feasible in all patients. The median procedural time was 64 minutes [45-94]. Only minor adverse events were reported (5 clinically asymptomatic cement leakages) but no severe complications. No post procedural adjacent fracture was reported during follow-up (median: 193 days [147-279]). The median VAS score decreased from 55 mm [50-70] before the procedure to 25 mm [5-30] at 2-month (P = .0003) and 30 mm [15-40] at 6-month follow-up (P = .14). The median ODI decreased from 23% [19-26] before the procedure to 12% [10-14] at 2-month (P = .03) and 12% [9-20] at 6-month follow-up (P = .47). CONCLUSION: Percutaneous transpedicular fixation of VCF by PEEK implants appears feasible and safe.


Assuntos
Benzofenonas , Estudos de Viabilidade , Fraturas por Compressão , Cetonas , Polietilenoglicóis , Polímeros , Fraturas da Coluna Vertebral , Humanos , Fraturas por Compressão/cirurgia , Fraturas por Compressão/diagnóstico por imagem , Masculino , Pessoa de Meia-Idade , Feminino , Fraturas da Coluna Vertebral/cirurgia , Fraturas da Coluna Vertebral/diagnóstico por imagem , Projetos Piloto , Estudos Prospectivos , Resultado do Tratamento , Medição da Dor
11.
Can Assoc Radiol J ; 75(3): 658-670, 2024 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-38444144

RESUMO

Interventional Oncology (IO) stands at the forefront of transformative cancer care, leveraging advanced imaging technologies and innovative interventions. This narrative review explores recent developments within IO, highlighting its potential impact facilitated by artificial intelligence (AI), personalized medicine and imaging innovations. The integration of AI in IO holds promise for accelerating tumour detection and characterization, guiding treatment strategies and refining predictive models. Imaging modalities, including functional MRI, PET and cone beam CT are reshaping imaging and precision. Navigation, fusion imaging, augmented reality and robotics have the potential to revolutionize procedural guidance and offer unparalleled accuracy. New developments are observed in embolization and ablative therapies. The pivotal role of genomics in treatment planning, targeted therapies and biomarkers for treatment response prediction underscore the personalization of IO. Quality of life assessment, minimizing side effects and long-term survivorship care emphasize patient-centred outcomes after IO treatment. The evolving landscape of IO training programs, simulation technologies and workforce competence ensures the field's adaptability. Despite barriers to adoption, synergy between interventional radiologists' proficiency and technological advancements hold promise in cancer care.


Assuntos
Oncologia , Neoplasias , Humanos , Neoplasias/diagnóstico por imagem , Neoplasias/terapia , Oncologia/métodos , Inteligência Artificial , Radiologia Intervencionista/métodos , Medicina de Precisão/métodos , Radiografia Intervencionista/métodos
12.
World J Urol ; 41(2): 303-313, 2023 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-33811291

RESUMO

PURPOSE: Robot-assisted partial nephrectomy (RAPN) is a difficult procedure with risk of significant perioperative complications. The objective was to evaluate the impact of preoperative planning and intraoperative guidance with 3D model reconstructions on perioperative outcomes of RAPN. METHODS: We conducted a retrospective analysis of all patients who underwent RAPN for kidney tumor by three high-volume expert surgeons from academic centers. Clinical data were collected prospectively after written consent into the French kidney cancer network database UroCCR (CNIL-DR 2013-206; NCT03293563). Our cohort was divided into two groups: 3D-Image guided RAPN group (3D-IGRAPN) and control group. A propensity score according to age, pre-operative renal function and RENAL tumor complexity score was used. Both surgical techniques were compared in terms of perioperative outcomes. RESULTS: The initial study cohort included 230 3D-IGRAPN and 415 control RAPN. Before propensity-score matching, patients in the 3D-IGRAPN group had a larger tumor (4.3 cm vs. 3.5 cm, P < 0.001) and higher RENAL complexity score (9 vs. 8, P < 0.001). Following propensity-score matching, there were 157 patients in both groups. The rate of major complications was lower for patients in the 3D-IGRAPN group (3.8% vs. 9.5%, P = 0.04). The median percentage of eGFR variation recorded at first follow-up was lower in the 3D-IGRAPN group (- 5.6% vs. - 10.5%, P = 0.002). The trifecta achievement rate was higher in the 3D-IGRAPN group (55.7% vs. 45.1%; P = 0.005). CONCLUSION: Three-dimensional kidney reconstructions use for pre-operative planning and intraoperative surgical guidance lowers the risk of complications and improve perioperative clinical outcomes of RAPN.


Assuntos
Neoplasias Renais , Procedimentos Cirúrgicos Robóticos , Humanos , Estudos Retrospectivos , Procedimentos Cirúrgicos Robóticos/métodos , Pontuação de Propensão , Nefrectomia/métodos , Neoplasias Renais/patologia , Resultado do Tratamento
13.
Eur Radiol ; 33(12): 8426-8435, 2023 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-37466710

RESUMO

PURPOSE: To compare the oncological and perioperative outcomes of robot-assisted partial nephrectomy (RPN) and percutaneous thermal ablation (PTA) for treatment of T1 renal cell cancer (RCC) in patients older than 75 years. MATERIALS AND METHODS: Retrospective national multicenter study included all patients older than 75 years treated for a T1 RCC by RPN or PTA between January 2010 and January 2021. Patients' characteristics, tumor data, and perioperative and oncological outcomes were compared. RESULTS: A total of 205 patients for 209 procedures (143 RPN and 66 PTA) were included. In the PTA group, patients were older (80.4 ± 3.7 vs. 79 ± 3.7 years (p = 0.01)); frailer (ASA score (2.43 ± 0.6 vs. 2.17 ± 0.6 (p < 0.01)); and more frequently had a history of kidney surgery (16.7% [11/66] vs. 5.6% [8/143] (p = 0.01)) than in the RPN group. Tumors were larger in the RPN group (2.7 ± 0.7 vs. 3.2 ± 0.9 cm (p < 0.01)). Operation time, length of hospital stay, and increase of creatinine serum level were higher in RPN (respectively 92.1 ± 42.7 vs. 150.7 ± 61.3 min (p < 0.01); 1.7 ± 1.4 vs. 4.2 ± 3.4 days (p < 0.01); 1.9 ± 19.3% vs. 10.1 ± 23.7 (p = 0.03)). Disease-free survival and time to progression were similar (respectively, HR 2.2; 95% CI 0.88-5.5; p = 0.09; HR 2.1; 95% CI 0.86-5.2; p = 0.1). Overall survival was shorter for PTA that disappeared after Cox adjusting model (HR 3.3; 95% CI 0.87-12.72; p = 0.08). CONCLUSION: Similar oncological outcomes are observed after PTA and RPN for T1 RCC in elderly patients. CLINICAL RELEVANCE STATEMENT: Robot-assisted partial nephrectomy and percutaneous thermal ablation have similar oncological outcomes for T1a kidney cancer in patients over 75 years; however, operative time, decrease in renal function, and length of hospital stay were lower with ablation. KEY POINTS: • After adjusting model for age and ASA score, similar oncological outcomes are observed after percutaneous thermal ablation and robot-assisted partial nephrectomy for T1 renal cell cancer in elderly patients. • Operation time, length of hospital stay, and increase of creatinine serum level were higher in the robot-assisted partial nephrectomy group.


Assuntos
Carcinoma de Células Renais , Ablação por Cateter , Neoplasias Renais , Procedimentos Cirúrgicos Robóticos , Robótica , Humanos , Idoso , Carcinoma de Células Renais/cirurgia , Carcinoma de Células Renais/patologia , Estudos Retrospectivos , Creatinina , Resultado do Tratamento , Neoplasias Renais/cirurgia , Neoplasias Renais/patologia , Nefrectomia/métodos , Procedimentos Cirúrgicos Robóticos/métodos , Néfrons/patologia , Néfrons/cirurgia , Ablação por Cateter/métodos
14.
J Vasc Interv Radiol ; 34(12): 2174-2179, 2023 12.
Artigo em Inglês | MEDLINE | ID: mdl-37673400

RESUMO

This retrospective study evaluated the feasibility and safety of percutaneous computed tomography (CT)-guided bone biopsies in patients with cancer using a patient-mounted robotic system with steering capabilities. The study included 39 patients (17 women, 22 men; median age, 65.5 years; interquartile range [IQR], 54.8-71.0 years). Forty biopsies were performed in the pelvis, spine, ribs, shoulder, femur, and sternum. The technical success rate was 100%, and the median trajectory length was 55.9 mm (IQR, 47.1-73.6 mm). Intermediate checkpoints were used in 8 biopsies. Median time from the first to final scan was 21 minutes (IQR, 17-37 minutes). The overall procedure time was 30 minutes (IQR, 24-36 minutes). The median dose length product and effective dose were 536.6 mGy⋅cm (IQR, 396.2-837.7 mGy∗cm) and 7.1 mSv (IQR, 4.7-10.8 mSv), respectively. No adverse events occurred. The diagnostic yield for cancer was 72.5%. Percutaneous robotic-assisted bone biopsies demonstrated high technical success, adequate diagnostic yield, and favorable safety profile.


Assuntos
Neoplasias , Procedimentos Cirúrgicos Robóticos , Masculino , Humanos , Feminino , Idoso , Estudos Retrospectivos , Estudos de Viabilidade , Procedimentos Cirúrgicos Robóticos/efeitos adversos , Biópsia Guiada por Imagem/efeitos adversos , Biópsia Guiada por Imagem/métodos , Tomografia Computadorizada por Raios X/métodos , Neoplasias/diagnóstico por imagem
15.
J Vasc Interv Radiol ; 34(4): 613-618, 2023 04.
Artigo em Inglês | MEDLINE | ID: mdl-36649805

RESUMO

PURPOSE: To evaluate the safety and effectiveness of preoperative embolization with n-butyl cyanoacrylate (nBCA) performed for metastatic spinal cord compression (MSCC) in limiting blood loss (BL). MATERIALS AND METHODS: In this institutional review board-approved retrospective study, clinical records from 2017 to 2022 were reviewed. Twenty consecutive patients (11 men and 9 women; mean age, 65.8 years ± 10.0; range, 45-82 years) underwent 21 preoperative spine tumor embolizations with nBCA. Angiograms were used to calculate the percentage reduction in tumor vascularity, and relevant clinical data (levels studied and embolized, fluoroscopy time [FT], reference dose [RD], and Kerma area product [KAP]) and operative data (BL and operative time [OT]) were analyzed. Adverse events and outcomes were recorded. RESULTS: A median of 2 levels were embolized per procedure (range, 1-5) but 4.9 were studied (range, 1-10). After embolization, tumor blush was reduced by a median of 87.3% (range, 50%-90%). The mean FT was 41 minutes ± 15.4 (range, 16-67 minutes), the mean RD was 1,977.1 mGy ± 1,794.3 (range, 450.2-6,319 mGy), and the mean KAP was 180.5 Gy·cm2 ± 166.2 (range, 30.4-504 Gy·cm2). The adverse event rate was 1 (4.7%) of the 21 embolizations because a weakness of lower extremities related to swelling was observed. Surgery was performed at a mean of 1.4 days ± 1 (range, 1-5 days) after embolization. The mean surgical estimated BL was 432.5 mL ± 328.5 (range, 25-1,100 mL), and the mean OT was 210.1 minutes ± 97.4 (range, 57-489 minutes). CONCLUSIONS: Preoperative embolization of tumors resected for MSCC with nBCA is a safe procedure allowing for performance of surgery with acceptable BL.


Assuntos
Embolização Terapêutica , Embucrilato , Compressão da Medula Espinal , Masculino , Humanos , Feminino , Idoso , Embucrilato/efeitos adversos , Compressão da Medula Espinal/diagnóstico por imagem , Compressão da Medula Espinal/etiologia , Compressão da Medula Espinal/terapia , Estudos Retrospectivos , Resultado do Tratamento , Perda Sanguínea Cirúrgica , Embolização Terapêutica/efeitos adversos , Embolização Terapêutica/métodos
16.
J Vasc Interv Radiol ; 34(7): 1192-1198, 2023 07.
Artigo em Inglês | MEDLINE | ID: mdl-37003579

RESUMO

PURPOSE: To retrospectively evaluate the relief of pain after percutaneous image-guided cryoablation of symptomatic extraperitoneal endometriosis (EE). MATERIAL AND METHODS: From 2017 to 2022, cryoablation of EE was performed at a single institution on a total of 47 lesions in 42 consecutive patients (median age, 37 years; interquartile range [IQR], 33-39.5 years). Patient and procedural characteristics were reviewed retrospectively. Tolerance and outcomes in terms of pain and patient satisfaction were evaluated. RESULTS: The median follow-up duration was 13.5 months (IQR, 1.1-37.7 months) after cryoablation. The median pain-free survival rate was 93.8% (95% confidence interval [CI], 77.3-98.4) at 6 months and 82.7% (95% CI, 58.8-93.5) after 12 months. Pain decreased from a median of 8/10 (IQR, 7-9) on the visual analog scale to 0/10 (IQR, 0-1) at the last follow-up (P < .0001). The median Patient Global Impression of Change score recorded at the last follow-up was 1/7 (IQR, 1-2). The efficacy rate of cryoablation to avoid secondary surgery was 92.8% (39/42) per patient and 93.6% (44/47) per nodule treated. Four patients (9.5%, 4/42) experienced an adverse event in the days following the procedure, and 1 patient (2%) experienced a severe adverse event. CONCLUSIONS: Percutaneous cryoablation is safe and effective in significantly reducing pain and obtaining local control of EE.


Assuntos
Criocirurgia , Endometriose , Feminino , Humanos , Adulto , Endometriose/diagnóstico por imagem , Endometriose/cirurgia , Endometriose/etiologia , Criocirurgia/efeitos adversos , Criocirurgia/métodos , Estudos Retrospectivos , Resultado do Tratamento , Dor/etiologia
17.
Eur Radiol ; 32(3): 1409-1418, 2022 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-34553254

RESUMO

OBJECTIVES: To evaluate MRI performance on both initial and long-term rheumatologic diagnosis of spondyloarthritis (SpA), taking into account clinical evolution and treatment response, and the impact of gadolinium injection. METHODS: In this single-center study, patients who underwent both spinal and sacroiliac (SI) joint MRI were prospectively recruited between May 2013 and January 2014 and followed for 7 years until 2020. Clinical, biological, and radiologic parameters were collected. At 7-year follow-up (2020), two independent readers reevaluated the initial MRI datasets for specific radiological features of SpA with a 5-point Likert scale to record the estimation of confidence. The centralized MRI interpretations were compared to the established rheumatologic diagnoses in 2013 and 2020. RESULTS: In total, 145 patients (52 men and 93 women) were included. During the 7-year follow-up, the number of patients with positive SpA diagnosis decreased from 93 to 58. Mean sensitivity, specificity, and accuracy of non-contrast MRI were 18, 97, and 49% and 27, 97, and 69% considering 2013 and 2020 rheumatologic diagnoses, respectively. Mean sensitivity, specificity, and accuracy values of gadolinium-enhanced MRI were 26, 97, and 54% and 38, 97, and 73% considering 2013 and 2020 diagnoses, respectively. Post-contrast MRI enabled identification of a subgroup of enthesis-only lesions, without any bone lesions, corresponding to 14% of the pathological cohort. It confirmed uncertain diagnoses in an additional 8.5% of pathological cases. CONCLUSIONS: MRI performance for SpA diagnosis is higher when long-term clinical follow-up is considered than when compared to initial diagnosis. Gadolinium injection increases MRI diagnostic performance and may demonstrate a pure enthesic form of the disease, without bone abnormality. KEY POINTS: • Compared to the rheumatologist's diagnosis over long-term clinical follow-up, MRI performance for SpA is higher than usually estimated. • Gadolinium injection increases diagnostic performance of MRI as it may identify a purely enthesis form of the disease. • Gadolinium injection should be discussed in patients for whom the diagnostic suspicion is strong and whose initial non-injected examination is normal or doubtful.


Assuntos
Espondilartrite , Espondiloartropatias , Feminino , Seguimentos , Gadolínio , Humanos , Imageamento por Ressonância Magnética , Masculino , Articulação Sacroilíaca , Sensibilidade e Especificidade , Espondilartrite/diagnóstico por imagem , Espondiloartropatias/diagnóstico por imagem
18.
J Vasc Interv Radiol ; 33(1): 14-18, 2022 01.
Artigo em Inglês | MEDLINE | ID: mdl-34980450

RESUMO

The purpose of this retrospective review was to evaluate SpineJack implantation in cancer-related vertebral compression fractures in 13 consecutive patients (mean age, 62.8 years ± 18.8). A total of 36 devices were inserted at 20 levels (13 [65%] lumbar and 7 [35%] thoracic vertebrae), with a mean Spinal Instability Neoplastic Score of 9.1 ± 2.1. Vertebral height restoration was observed in 10 levels (50%), with a mean height restoration of 5.6 mm ± 2.2 (interquartile range [IQR], 4-7.5). A total of 6 cement leakages were observed in 3 (23%) patients without clinical consequences. No severe adverse events were observed. One adjacent fracture occurred. Average pain scores on the visual analog scale significantly improved from 5.5 ± 1.8 (IQR, 4-7) preoperatively to 1.5 ± 2.2 (IQR, 0-3.3) at 1 month (P < .01) and to 1.5 ± 1.3 (IQR, 0.3-2.8) at 6 months (P < .01). In this small cohort, SpineJack offered pain relief in cancer-related fractures without an observed increase in adverse events.


Assuntos
Fraturas por Compressão , Cifoplastia , Neoplasias , Fraturas por Osteoporose , Fraturas da Coluna Vertebral , Cimentos Ósseos/efeitos adversos , Fraturas por Compressão/diagnóstico por imagem , Fraturas por Compressão/etiologia , Fraturas por Compressão/cirurgia , Humanos , Vértebras Lombares/diagnóstico por imagem , Vértebras Lombares/lesões , Pessoa de Meia-Idade , Estudos Retrospectivos , Fraturas da Coluna Vertebral/diagnóstico por imagem , Fraturas da Coluna Vertebral/etiologia , Fraturas da Coluna Vertebral/cirurgia , Vértebras Torácicas/diagnóstico por imagem , Resultado do Tratamento
19.
Int J Hyperthermia ; 39(1): 664-674, 2022.
Artigo em Inglês | MEDLINE | ID: mdl-35465811

RESUMO

Microwave ablation (MWA) is becoming an increasingly important minimally invasive treatment option for localized tumors in many organ systems due to recent advancements in microwave technology that have conferred many advantages over other tumor ablation modalities. Despite these improvements in technology and development of applicators for site-specific tumor applications, the vast majority of commercially available MWA applicators are generally designed to create large-volume, symmetric, ellipsoid or spherically-shaped treatment zones and often lack the consistency, predictability, and spatial control needed to treat tumor targets near critical structures that are vulnerable to inadvertent thermal injury. The relatively new development and ongoing translation of directional microwave ablation (DMWA) technology, however, has the potential to confer an added level of control over the treatment zone shape relative to applicator position, and shows great promise to expand MWA's clinical applicability in treating tumors in challenging locations. This paper presents a review of the industry-standard commercially available MWA technology, its clinical applications, and its limitations when used for minimally-invasive tumor treatment in medical practice followed by discussion of new advancements in experimental directional microwave ablation (DMWA) technology, various techniques and approaches to its use, and examples of how this technology may be used to treat tumors in challenging locations that may otherwise preclude safe treatment by conventional omni-directional MWA devices.


Assuntos
Técnicas de Ablação , Neoplasias , Ablação por Radiofrequência , Técnicas de Ablação/métodos , Humanos , Micro-Ondas/uso terapêutico , Neoplasias/cirurgia
20.
Eur Radiol ; 31(9): 6471-6479, 2021 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-33693993

RESUMO

OBJECTIVE: To assess the influence of patient characteristics, anatomical conditions, and technical factors on radiation exposure during prostatic arteries embolization (PAE) performed for benign prostatic hyperplasia. MATERIALS AND METHODS: Patient characteristics (age, body mass index (BMI)), anatomical conditions (number of prostatic arteries, anastomosis), and technical factors (use of cone beam computed tomography (CBCT), large display monitor (LDM), and magnification) were recorded as well as total air kerma (AK), dose area product (DAP), fluoroscopy time (FT), and number of acquisitions (NAcq). Associations between potential dose-influencing factors and AK using univariate analysis and a multiple linear regression model were assessed. RESULTS: Forty-one consecutive men (68 ± 8 years, min-max: 40-76) were included. LDM and CBCT decreased the use of small field of view with 13.9 and 3.8% respectively, both p < 0.001. The use of a LDM significantly reduced AK (1006.6 ± 471.7 vs. 1412 ± 754.6 mGy, p = 0.02), DAP (119.4 ± 64.4 vs. 167.9 ± 99.2, p = 0.04), FT (40.4 ± 11.5 vs. 53.6 ± 25.5 min, p = 0.01), and NAcq (16.3 ± 6.3 vs. 18.2 ± 7, p = 0.04). In multivariate analysis, AK reduction was associated with lower patient BMI (ß = 0.359, p = 0.002), shorter FT (ß = 0.664, p < 0.001) and CBCT use (ß = - 0.223, p = 0.03), and decreased NAcq (ß = 0.229, p = 0.04). CONCLUSION: LDM and CBCT are important technical dose-related factors to help reduce radiation exposure during PAE, and should be considered in standard practice. KEY POINTS: • The use of large display monitor (LDM) and cone beam computed tomography (CBCT) both decreased the need for magnification during prostatic arteries embolization (PAE). • The use of LDM reduces radiation exposure during PAE. • Total air kerma is associated with patient's body mass index, fluoroscopy time, CBCT, and the number of acquisitions.


Assuntos
Embolização Terapêutica , Hiperplasia Prostática , Exposição à Radiação , Artérias/diagnóstico por imagem , Tomografia Computadorizada de Feixe Cônico , Humanos , Masculino , Próstata/diagnóstico por imagem , Hiperplasia Prostática/diagnóstico por imagem , Hiperplasia Prostática/terapia , Exposição à Radiação/prevenção & controle , Estudos Retrospectivos
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA