Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 143
Filtrar
Mais filtros

Base de dados
Tipo de documento
Intervalo de ano de publicação
1.
Lancet ; 402(10416): 1979-1990, 2023 11 25.
Artigo em Inglês | MEDLINE | ID: mdl-37898137

RESUMO

BACKGROUND: Biodegradable polymer sirolimus-eluting stents improve early stent-related clinical outcomes compared to durable polymer everolimus-eluting stents in patients with ST-segment elevation myocardial infarction (STEMI) undergoing primary percutaneous coronary intervention. The long-term advantages of biodegradable polymer sirolimus-eluting stents after complete degradation of its polymer coating in patients with STEMI remains however uncertain. METHODS: BIOSTEMI Extended Survival (BIOSTEMI ES) was an investigator-initiated, follow-up extension study of the BIOSTEMI prospective, multicentre, single-blind, randomised superiority trial that compared biodegradable polymer sirolimus-eluting stents with durable polymer everolimus-eluting stents in patients with STEMI undergoing primary percutaneous coronary intervention at ten hospitals in Switzerland. All individuals who had provided written informed consent for participation in the BIOSTEMI trial were eligible for this follow-up study. The primary endpoint was target lesion failure, defined as a composite of cardiac death, target vessel myocardial re-infarction, or clinically indicated target lesion revascularisation, at 5 years. Superiority of biodegradable polymer sirolimus-eluting stents over durable polymer everolimus-eluting stents was declared if the Bayesian posterior probability for a rate ratio (RR) of less than 1 was greater than 0·975. Analyses were performed according to the intention-to-treat principle. The study was registered with ClinicalTrials.gov, NCT05484310. FINDINGS: Between April 26, 2016, and March 9, 2018, 1300 patients with STEMI (1622 lesions) were randomly allocated in a 1:1 ratio to treatment with biodegradable polymer sirolimus-eluting stents (649 patients, 816 lesions) or durable polymer everolimus-eluting stents (651 patients, 806 lesions). At 5 years, the primary composite endpoint of target lesion failure occurred in 50 (8%) patients treated with biodegradable polymer sirolimus-eluting stents and in 72 (11%) patients treated with durable polymer everolimus-eluting stents (difference of -3%; RR 0·70, 95% Bayesian credible interval 0·51-0·95; Bayesian posterior probability for superiority 0·988). INTERPRETATION: In patients undergoing primary percutaneous coronary intervention for STEMI, biodegradable polymer sirolimus-eluting stents were superior to durable polymer everolimus-eluting stents with respect to target lesion failure at 5 years of follow-up. The difference was driven by a numerically lower risk for ischaemia-driven target lesion revascularisation. FUNDING: Biotronik.


Assuntos
Stents Farmacológicos , Infarto do Miocárdio , Intervenção Coronária Percutânea , Infarto do Miocárdio com Supradesnível do Segmento ST , Humanos , Sirolimo/uso terapêutico , Everolimo/uso terapêutico , Seguimentos , Infarto do Miocárdio com Supradesnível do Segmento ST/cirurgia , Infarto do Miocárdio com Supradesnível do Segmento ST/tratamento farmacológico , Polímeros , Teorema de Bayes , Método Simples-Cego , Estudos Prospectivos , Resultado do Tratamento , Implantes Absorvíveis , Infarto do Miocárdio/etiologia , Intervenção Coronária Percutânea/métodos
2.
Eur J Clin Invest ; : e14317, 2024 Oct 13.
Artigo em Inglês | MEDLINE | ID: mdl-39397275

RESUMO

BACKGROUND: The clinical relevance of cardiac troponin (cTn) elevation in takotsubo syndrome (TTS) remains uncertain. The present study sought to investigate the role of cardiac troponin (cTn) elevations in mortality prediction of patients with Takotsubo syndrome (TTS). METHODS: Patients enrolled in the International Takotsubo (InterTAK) Registry from January 2011 to February 2020 with available data on peak cTn levels were included in the analysis. Peak cTn levels during the index hospitalization were used to define clinically relevant myocardial injury. The threshold at which clinically relevant myocardial injury drives mortality at 1 year was identified using restricted cubic spline analysis. RESULTS: Out of 2'938 patients, 222 (7.6%) patients died during 1-year follow-up. A more than 28.8-fold increase of cTn above the upper reference limit was identified as threshold for clinically relevant myocardial injury. The presence of clinically relevant myocardial injury was significantly associated with an increased risk of mortality at 5 years (adjusted HR 1.58, 95% CI 1.18-2.12, p =.002). Clinically relevant myocardial injury was related to an increased 5-year mortality risk in patients with apical TTS (adjusted HR 1.57, 95% CI 1.21-2.03, p =.001), in presence of physical stressors (adjusted HR 1.60, 95% CI 1.22-2.11, p =.001), and in absence of emotional stressors (adjusted HR 1.49, 95% CI, 1.17-1.89, p =.001). CONCLUSION: This study for the first time determined a troponin threshold for the identification of TTS patients at excess risk of mortality. These findings advance risk stratification in TTS and assist in identifying patients in need for close monitoring and follow-up.

3.
Catheter Cardiovasc Interv ; 104(1): 134-144, 2024 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-38736247

RESUMO

BACKGROUND: In transcatheter aortic valve replacement (TAVR), transfemoral (TF) access offers several advantages over alternative access routes. Advances in sheaths and valve delivery technology have catalyzed the feasibility of TF-TAVR, even in challenging anatomies. AIMS: Report procedural characteristics and outcomes of a TAVR program aiming for a 100% TF access rate. METHODS: Consecutive patients undergoing TAVR were enrolled in a prospective registry. Equipment used to facilitate TF-access in challenging anatomies included low-profile sheaths, dilatators, peripheral balloons, covered and uncovered self-expanding and balloon-expandable stents, and intravascular lithotripsy (IVL). RESULTS: A total of 400 patients with a mean age of 81 ± 6 years (42% female) were analyzed. Minimal iliofemoral artery diameter (MLD) of the main access side was <5 mm in 42 (10.5%), extreme tortuosity was present in 65 (16.3%), and severe calcification in 59 (14.8%). TF-access was successful in 399 (99.8%) patients. A transaxillary access was used in one patient. In multivariable analysis, an MLD < 5 mm was the strongest predictor for vascular complications (11.9% vs. 3.9%, OR: 3.86, 95% CI: 1.38-10.8, p = 0.01). Such patients also had more major/life-threatening bleeding (14.2% vs. 3.1%, p < 0.001) and required more planned and unplanned peripheral interventions to enable TF access (35.8% vs. 3.4%, p < 0.001). CONCLUSION: Our study shows that utilization of dedicated sheaths, peripheral balloons, stents, and IVL enables TAVR via TF access in >99% of patients. However, rates of vascular and bleeding complications in patients with narrow iliofemoral arteries (MLD < 5 mm) were high.


Assuntos
Estenose da Valva Aórtica , Valva Aórtica , Cateterismo Periférico , Artéria Femoral , Punções , Sistema de Registros , Substituição da Valva Aórtica Transcateter , Humanos , Feminino , Masculino , Artéria Femoral/diagnóstico por imagem , Idoso de 80 Anos ou mais , Substituição da Valva Aórtica Transcateter/instrumentação , Substituição da Valva Aórtica Transcateter/efeitos adversos , Resultado do Tratamento , Idoso , Cateterismo Periférico/efeitos adversos , Fatores de Risco , Valva Aórtica/cirurgia , Valva Aórtica/diagnóstico por imagem , Valva Aórtica/fisiopatologia , Estenose da Valva Aórtica/cirurgia , Estenose da Valva Aórtica/diagnóstico por imagem , Estenose da Valva Aórtica/fisiopatologia , Estudos Prospectivos , Fatores de Tempo , Próteses Valvulares Cardíacas
4.
Catheter Cardiovasc Interv ; 102(2): 339-347, 2023 08.
Artigo em Inglês | MEDLINE | ID: mdl-37232417

RESUMO

BACKGROUND: Growing interest in neuroprotection in transcatheter aortic valve replacement (TAVR) has catalyzed the development of cerebral protection systems (CPS). OBJECTIVES: Report insights from consecutive real-world patients undergoing TAVR with the Sentinel-CPS. METHODS: Patients with severe aortic stenosis undergoing TAVR from April 2019 to May 2022 were enrolled in a prospective registry. The reason for unsuccessful Sentinel-CPS deployment and the amount of debris captured by the filters were prospectively recorded. RESULTS: The Sentinal CPS was successfully deployed in 330 patients (85%, Group 1). Deployment was not attempted, unsuccessful or only partially successful in 59 patients (15%, Group 2), caused by anatomical factors such as tortuosity, heavy calcification or small dimensions of radial or brachial artery in 46, technical aspects such as puncture failure or dissection in 5 or use of right radial access for the pigtail in 6. Debris was captured in 98% of patients in Group 1. In 40%, the amount of debris was graded moderate or extensive. Predictors for moderate/extensive debris were moderate/severe aortic calcification (OR 1.50, CI 1.05-2.15, p = 0.03), pre- and postdilatation (OR 1.97, CI 1.02-3.79, p = 0.04 and OR 1.71, CI 1.01-2.89, p = 0.048). The risk of stroke was numerically lower in patients who underwent TAVR with the Sentinel CPS (2.1 vs. 5.1%, respectively, p = 0.15). There was no stroke during CPS deployment, but one patient had a stroke immediately after device retrieval. CONCLUSIONS: The Sentinel-CPS was successfully deployed in 85% of patients. Predictors for moderate/extensive debris captured were moderate/severe aortic calcification, pre- and postdilatation.


Assuntos
Estenose da Valva Aórtica , Dispositivos de Proteção Embólica , Acidente Vascular Cerebral , Substituição da Valva Aórtica Transcateter , Humanos , Valva Aórtica/diagnóstico por imagem , Valva Aórtica/cirurgia , Estenose da Valva Aórtica/diagnóstico por imagem , Estenose da Valva Aórtica/cirurgia , Estenose da Valva Aórtica/etiologia , Resultado do Tratamento , Acidente Vascular Cerebral/etiologia , Fatores de Risco
5.
BMC Cardiovasc Disord ; 23(1): 506, 2023 10 12.
Artigo em Inglês | MEDLINE | ID: mdl-37828421

RESUMO

OBJECTIVES: It is uncertain, if omitting post-dilatation and stent oversizing (stent optimization) is safe and may decrease the risk for distal thrombus embolization (DTE) in STEMI patients with large thrombus burden (LTB). BACKGROUND: In patients with ST-segment elevation myocardial infarction (STEMI) undergoing primary percutaneous coronary intervention (pPCI) with stenting, (DTE) and flow deterioration are common and increase infarct size leading to worse outcomes. METHODS: From a prospective registry, 74 consecutive STEMI patients with LTB undergoing pPCI with stenting and intentionally deferred stent optimization were analyzed. Imaging data and outcomes up to 2 years follow-up were analyzed. RESULTS: Overall, 74 patients (18% females) underwent deferred stent optimization. Direct stenting was performed in 13 (18%) patients. No major complications occurred during pPCI. Staged stent optimization was performed after a median of 4 (interquartile range (IQR) 3; 7) days. On optical coherence tomography, under-expansion and residual thrombus were present in 59 (80%) and 27 (36%) cases, respectively. During deferred stent optimization, we encountered no case of flow deterioration (slow or no-reflow) or side branch occlusion. Minimal lumen area (mm2) and stent expansion (%) were corrected from 4.87±1.86mm to 6.82±2.36mm (p<0.05) and from 69±18% to 91±12% (p<0.001), respectively. During follow-up, 1 patient (1.4%) required target lesion revascularization and 1 (1.4%) patient succumbed from cardiovascular death. CONCLUSIONS: Among STEMI patients with LTB, deferring stent optimization in the setting of pPCI appears safe and potentially mitigates the risk of DTE. The impact of this approach on infarct size and clinical outcomes warrants further investigation in a dedicated trial.


Assuntos
Trombose Coronária , Intervenção Coronária Percutânea , Infarto do Miocárdio com Supradesnível do Segmento ST , Feminino , Humanos , Masculino , Infarto do Miocárdio com Supradesnível do Segmento ST/diagnóstico por imagem , Infarto do Miocárdio com Supradesnível do Segmento ST/terapia , Infarto do Miocárdio com Supradesnível do Segmento ST/etiologia , Estudos Prospectivos , Resultado do Tratamento , Trombose Coronária/diagnóstico por imagem , Trombose Coronária/etiologia , Trombose Coronária/terapia , Intervenção Coronária Percutânea/efeitos adversos , Intervenção Coronária Percutânea/métodos , Stents , Angiografia Coronária/métodos
6.
BMC Cardiovasc Disord ; 23(1): 176, 2023 03 31.
Artigo em Inglês | MEDLINE | ID: mdl-37003986

RESUMO

BACKGROUND: A decade ago, the iopromide-paclitaxel coated balloon (iPCB) was added to the cardiologist's toolbox to initially treat in-stent restenosis followed by the treatment of de novo coronary lesions. In the meantime, DES technologies have been substantially improved to address in-stent restenosis and thrombosis, and shortened anti-platelet therapy. Recently, sirolimus-coated balloon catheters (SCB) have emerged to provide an alternative drug to combat restenosis. METHODS: The objective of this study is to determine the safety and efficacy of a novel crystalline sirolimus-coated balloon (cSCB) technology in an unselective, international, large-scale patient population. Percutaneous coronary interventions of native stenosis, in-stent stenosis, and chronic total occlusions with the SCB in patients with stable coronary artery disease or acute coronary syndrome were included. The primary outcome variable is the target lesion failure (TLF) rate at 12 months, defined as the composite rate of target vessel myocardial infarction (TV-MI), cardiac death or ischemia-driven target lesion revascularization (TLR). The secondary outcome variables include TLF at 24 months, ischemia driven TLR at 12 and 24 months and all-cause death, cardiac death at 12 and 24 months. DISCUSSION: Since there is a wealth of patient-based all-comers data for iPCB available for this study, a propensity-score matched analysis is planned to compare cSCB and iPCB for the treatment of de novo and different types of ISR. In addition, pre-specified analyses in challenging lesion subsets such as chronic total occlusions will provide evidence whether the two balloon coating technologies differ in their clinical benefit for the patient. TRIAL REGISTRATION NUMBER: ClinicalTrials.gov Identifier: NCT04470934.


Assuntos
Fármacos Cardiovasculares , Doença da Artéria Coronariana , Reestenose Coronária , Stents Farmacológicos , Humanos , Angioplastia/efeitos adversos , Fármacos Cardiovasculares/efeitos adversos , Constrição Patológica/complicações , Doença da Artéria Coronariana/diagnóstico por imagem , Doença da Artéria Coronariana/terapia , Doença da Artéria Coronariana/complicações , Reestenose Coronária/diagnóstico por imagem , Reestenose Coronária/etiologia , Reestenose Coronária/terapia , Stents Farmacológicos/efeitos adversos , Paclitaxel/efeitos adversos , Sirolimo/efeitos adversos , Resultado do Tratamento , Ensaios Clínicos como Assunto
7.
Catheter Cardiovasc Interv ; 99(6): 1848-1856, 2022 05.
Artigo em Inglês | MEDLINE | ID: mdl-35114065

RESUMO

OBJECTIVES: Investigate the impact of concomitant tricuspid regurgitation (TR) on clinical outcomes during long-term follow-up in patients undergoing percutaneous treatment of mitral regurgitation (MR) with the MitraClip system. BACKGROUND: Patients undergoing mitral repair using the MitraClip frequently present with concomitant TR. It is uncertain how the presence of TR impacts the long-term outcomes of such patients. METHODS: We analyzed consecutive patients with MitraClip implantation from the prospective MitraSwiss registry. Endpoints were all-cause mortality, hospitalization for heart failure, and the composite endpoint of the two. RESULTS: We enrolled 177 patients (mean age 76 ± 9 years, 37% female). Acute procedural success was achieved in 149 (84%). Concomitant moderate or severe TR was present in 31% at baseline and 32% before discharge. After a median follow-up of 1103 days (IQR: 555-1766 days), 70 (40%) of patients had died, and 34 (19%) were hospitalized for heart failure. In multivariable analysis, TR at baseline was associated with an increase in all-cause mortality (HR: 2.34, 95% CI: 1.36-4.03, p < 0.01), hospitalization for heart failure (HR: 3.19, 95% CI: 1.37-7.41, p = 0.01), and the composite endpoint (HR: 2.00, 95% CI: 1.19-3.36, p = 0.01). CONCLUSION: Despite treatment of MR, TR did not improve in most patients. The presence of relevant TR at baseline was associated with reduced survival and higher rates of hospitalization for heart failure. More research is needed to understand the causal role of TR in such patients and to investigate if simultaneous treatment of concomitant TR may improve prognosis in patients undergoing percutaneous treatment of MR.


Assuntos
Insuficiência Cardíaca , Implante de Prótese de Valva Cardíaca , Insuficiência da Valva Mitral , Insuficiência da Valva Tricúspide , Idoso , Idoso de 80 Anos ou mais , Feminino , Insuficiência Cardíaca/terapia , Implante de Prótese de Valva Cardíaca/efeitos adversos , Humanos , Masculino , Insuficiência da Valva Mitral/complicações , Insuficiência da Valva Mitral/diagnóstico por imagem , Insuficiência da Valva Mitral/cirurgia , Estudos Prospectivos , Estudos Retrospectivos , Resultado do Tratamento , Insuficiência da Valva Tricúspide/complicações , Insuficiência da Valva Tricúspide/diagnóstico por imagem , Insuficiência da Valva Tricúspide/terapia
8.
Catheter Cardiovasc Interv ; 98(3): E462-E465, 2021 09.
Artigo em Inglês | MEDLINE | ID: mdl-33847463

RESUMO

OBJECTIVES: Report MANTA-associated vascular complications after implementation of key insights on failure mechanisms. BACKGROUND: The MANTA vascular closure device is utilized to close large-bore arterial access sites. We have previously identified and published the mechanisms and predictors of MANTA-associated vascular complications. We identified three distinct mechanisms leading to MANTA-associated vascular complications, predictors were a common femoral artery (CFA) diameter <6 mm and clinically established peripheral artery disease (PAD). METHODS: We compared 100 consecutive patients of the initial cohort (first n = 100) with consecutive patients in which the key insights acquired in the initial cohort were implemented (second n = 100). RESULTS: The initial cohort (n = 100 patients) had a MANTA-related vascular complication rate of 11% (7% major and 4% minor), and 14% MANTA-related bleeding complications. In a subsequent cohort of n = 100 patients, we applied the abovementioned findings: we did not use the MANTA device if the CFA was <6 mm and in patients with PAD. In addition, femoral puncture was ultrasound guided. This strategy led to a decline in MANTA-related vascular complication rates: 2% (1% major and 1% minor) p = .03, as well as a reduction in MANTA-related bleeding complications to 5% p = .01. To the best of our knowledge, this is the lowest rate of MANTA-related vascular complication reported thus far. CONCLUSIONS: Our strategy achieves low MANTA-related vascular and bleeding complication rates. Careful and critical examination of complications can lead to rapid identification of complication mechanism and its predictors. In turn, rapid implementation of these insights can lead to a decline in complication rates.


Assuntos
Cateterismo Periférico , Dispositivos de Oclusão Vascular , Artéria Femoral/diagnóstico por imagem , Técnicas Hemostáticas , Humanos , Fatores de Tempo , Resultado do Tratamento
9.
Arterioscler Thromb Vasc Biol ; 40(1): 279-287, 2020 01.
Artigo em Inglês | MEDLINE | ID: mdl-31766870

RESUMO

OBJECTIVE: Takotsubo syndrome (TTS) is characterized by acute left ventricular dysfunction, which can contribute to intraventricular thrombus and embolism. Still, prevalence and clinical impact of thrombus formation and embolic events on outcome of TTS patients remain unclear. This study aimed to investigate clinical features and outcomes of patients with and without intraventricular thrombus or embolism. Additionally, factors associated with thrombus formation or embolism, as well as predictors for mortality, were identified. Approach and Results: TTS patients enrolled in the International Takotsubo Registry at 28 centers in Australia, Europe, and the United States were dichotomized according to the occurrence/absence of intraventricular thrombus or embolism. Patients with intraventricular thrombus or embolism were defined as the ThrombEmb group. Of 1676 TTS patients, 56 (3.3%) patients developed intraventricular thrombus and/or embolism following TTS diagnosis (median time interval, 2.0 days [range, 0-38 days]). Patients in the ThrombEmb group had a different clinical profile including lower left ventricular ejection fraction, higher prevalence of the apical type, elevated levels of troponin and inflammatory markers, and higher prevalence of vascular disease. In a Firth bias-reduced penalized-likelihood logistic regression model apical type, left ventricular ejection fraction ≤30%, previous vascular disease, and a white blood cell count on admission >10×103 cells/µL emerged as independent predictors for thrombus formation or embolism. CONCLUSIONS: Intraventricular thrombus or embolism occur in 3.3% of patients in the acute phase of TTS. A simple risk score including clinical parameters associated with intraventricular thrombus formation or embolism identifies patients at increased risk. CLINICAL TRIAL REGISTRATION: URL: http://www.clinicaltrials.gov. Unique identifier: NCT01947621.


Assuntos
Embolia/etiologia , Sistema de Registros , Medição de Risco/métodos , Cardiomiopatia de Takotsubo/complicações , Trombose/etiologia , Idoso , Austrália/epidemiologia , Angiografia Coronária , Eletrocardiografia , Embolia/diagnóstico , Embolia/epidemiologia , Europa (Continente)/epidemiologia , Feminino , Seguimentos , Cardiopatias/diagnóstico , Cardiopatias/epidemiologia , Cardiopatias/etiologia , Ventrículos do Coração , Humanos , Incidência , Imagem Cinética por Ressonância Magnética , Masculino , Ventriculografia com Radionuclídeos , Fatores de Risco , Taxa de Sobrevida/tendências , Cardiomiopatia de Takotsubo/diagnóstico , Trombose/diagnóstico , Trombose/epidemiologia , Fatores de Tempo , Estados Unidos/epidemiologia
10.
Eur Heart J ; 41(34): 3255-3268, 2020 09 07.
Artigo em Inglês | MEDLINE | ID: mdl-32484517

RESUMO

AIMS: Takotsubo syndrome (TTS) is an acute heart failure syndrome, which shares many features with acute coronary syndrome (ACS). Although TTS was initially described with angiographically normal coronary arteries, smaller studies recently indicated a potential coexistence of coronary artery disease (CAD) in TTS patients. This study aimed to determine the coexistence, features, and prognostic role of CAD in a large cohort of patients with TTS. METHODS AND RESULTS: Coronary anatomy and CAD were studied in patients diagnosed with TTS. Inclusion criteria were compliance with the International Takotsubo Diagnostic Criteria for TTS, and availability of original coronary angiographies with ventriculography performed during the acute phase. Exclusion criteria were missing views, poor quality of angiography loops, and angiography without ventriculography. A total of 1016 TTS patients were studied. Of those, 23.0% had obstructive CAD, 41.2% had non-obstructive CAD, and 35.7% had angiographically normal coronary arteries. A total of 47 patients (4.6%) underwent percutaneous coronary intervention, and 3 patients had acute and 8 had chronic coronary artery occlusion concomitant with TTS, respectively. The presence of CAD was associated with increased incidence of shock, ventilation, and death from any cause. After adjusting for confounders, the presence of obstructive CAD was associated with mortality at 30 days. Takotsubo syndrome patients with obstructive CAD were at comparable risk for shock and death and nearly at twice the risk for ventilation compared to an age- and sex-matched ACS cohort. CONCLUSIONS: Coronary artery disease frequently coexists in TTS patients, presents with the whole spectrum of coronary pathology including acute coronary occlusion, and is associated with adverse outcome. TRIAL REGISTRATION: ClinicalTrials.gov number: NCT01947621.


Assuntos
Síndrome Coronariana Aguda , Doença da Artéria Coronariana , Cardiomiopatia de Takotsubo , Angiografia Coronária , Doença da Artéria Coronariana/complicações , Doença da Artéria Coronariana/diagnóstico por imagem , Humanos , Incidência , Cardiomiopatia de Takotsubo/complicações , Cardiomiopatia de Takotsubo/epidemiologia
11.
Catheter Cardiovasc Interv ; 96(6): E640-E645, 2020 11.
Artigo em Inglês | MEDLINE | ID: mdl-31971346

RESUMO

OBJECTIVES: This study aimed to investigate the safety and efficacy of ACURATE neo transcatheter aortic valve replacement (TAVR) facilitated by predilatation with the nonocclusive TrueFlow balloon catheter. BACKGROUND: Now that TAVR is moving forward, physicians have attempted to simplify and streamline the procedure and the so-called minimalist approach has become more popular. METHODS: We enrolled 142 patients (mean age: 82 ± 5 years, 61% female) in a prospective registry. Patients at low risk for intraprocedural third-degree atrioventricular block (AVB) underwent TAVR with the TrueFlow balloon without rapid pacing and without insertion of a provisional pacemaker (n = 121). The remaining 21 patients were predilated with rapid pacing using a provisional pacemaker and a standard balloon. RESULTS: Predilatation with the TrueFlow balloon was successful in all 121 patients. Postdilatation was less frequently required after predilatation with the TrueFlow (25% vs. 57%, p = .003). Moreover, median procedural duration with the TrueFlow was significantly shorter (42 [interquartile range, IQR: 34-53] vs. 55 [IQR: 46-61] min, p = .004). In-hospital outcomes were similar. At 30 days, there was no mortality, two (1%) patients had suffered a stroke and only four (3%) had required implantation of a new pacemaker. CONCLUSION: Among patients with a low risk for intraprocedural third-degree AVB, the TrueFlow nonocclusive balloon catheter facilitates implantation of the ACURATE neo without the necessity of rapid pacing and a provisional pacemaker.


Assuntos
Estenose da Valva Aórtica/cirurgia , Valva Aórtica/cirurgia , Valvuloplastia com Balão/instrumentação , Cateteres Cardíacos , Cateterismo Periférico , Artéria Femoral , Próteses Valvulares Cardíacas , Substituição da Valva Aórtica Transcateter/instrumentação , Idoso , Idoso de 80 Anos ou mais , Valva Aórtica/diagnóstico por imagem , Valva Aórtica/fisiopatologia , Estenose da Valva Aórtica/diagnóstico por imagem , Estenose da Valva Aórtica/fisiopatologia , Bloqueio Atrioventricular/etiologia , Bloqueio Atrioventricular/fisiopatologia , Bloqueio Atrioventricular/prevenção & controle , Valvuloplastia com Balão/efeitos adversos , Cateterismo Periférico/efeitos adversos , Feminino , Humanos , Masculino , Estudos Prospectivos , Desenho de Prótese , Recuperação de Função Fisiológica , Sistema de Registros , Fatores de Tempo , Substituição da Valva Aórtica Transcateter/efeitos adversos , Resultado do Tratamento
12.
Europace ; 22(1): 84-89, 2020 01 01.
Artigo em Inglês | MEDLINE | ID: mdl-31518403

RESUMO

AIMS: Pulmonary vein isolation (PVI) using ablation index (AI) incorporates stability, contact force (CF), time, and power. The CLOSE protocol combines AI and ≤6 mm interlesion distance. Safety concerns are raised about surround flow ablation catheters (STSF). To compare safety and effectiveness of an atrial fibrillation (AF) ablation strategy using AI vs. CLOSE protocol using STSF. METHODS AND RESULTS: First cluster was treated using AI and second cluster using CLOSE. Procedural data, safety, and recurrence of any atrial tachycardia (AT) or AF >30 s were collected prospectively. All Classes 1c and III anti-arrhythmic drugs (AAD) were stopped after the blanking period. In total, all 215 consecutive patients [AI: 121 (paroxysmal: n = 97), CLOSE: n = 94 (paroxysmal: n = 74)] were included. Pulmonary vein isolation was reached in all in similar procedure duration (CLOSE: 107 ± 25 vs. AI: 102 ± 24 min; P = 0.1) and similar radiofrequency time (CLOSE: 36 ± 11 vs. AI: 37 ± 8 min; P = 0.4) but first pass isolation was higher in CLOSE vs. AI [left veins: 90% vs. 80%; P < 0.05 and right veins: 84% vs. 73%; P < 0.05]. Twelve-month off-AAD freedom of AF/AT was higher in CLOSE vs. AI [79% (paroxysmal: 85%) vs. 64% (paroxysmal: 68%); P < 0.05]. Only four patients (2%) without recurrence were on AAD during follow-up. Major complications were similar (CLOSE: 2.1% vs. AI: 2.5%; P = 0.87). CONCLUSION: The CLOSE protocol is more effective than a PVI approach solely using AI, especially in paroxysmal AF. In this off-AAD study, 79% of patients were free from AF/AT during 12-month follow-up. The STSF catheter appears to be safe using conventional CLOSE targets.


Assuntos
Fibrilação Atrial , Ablação por Cateter , Veias Pulmonares , Fibrilação Atrial/diagnóstico , Fibrilação Atrial/cirurgia , Catéteres , Humanos , Veias Pulmonares/cirurgia , Recidiva , Resultado do Tratamento
13.
BMC Geriatr ; 20(1): 287, 2020 08 12.
Artigo em Inglês | MEDLINE | ID: mdl-32787787

RESUMO

BACKGROUND: This study evaluated the use of comprehensive geriatric assessment (CGA) in older patients undergoing pacemaker implantation. METHODS: In this prospective cohort, CGA was performed in 197 patients ≥75 years at pacemaker implantation and yearly thereafter. CGA embraced the following domains: cognition, mobility, nutrition, activities of daily living (ADLs), and falls (with or without loss of consciousness). Based on comorbidities, the Charlson comorbidity index (CCI) was calculated. For predictive analysis, logistic regression was used. RESULTS: During a mean follow-up duration of 2.4 years, the incidence rates of syncope decreased from 0.46 to 0.04 events per year (p < 0.001), and that of falls without loss of consciousness from 0.27 to 0.15 (p < 0.001) before vs. after implantation. Sixty-three patients (32.0%) died. Impaired mobility (OR 2.60, 95%CI 1.22-5.54, p = 0.013), malnutrition (OR 3.26, 95%CI 1.52-7.01, p = 0.002), and a higher CCI (OR per point increase 1.25, 95%CI 1.04-1.50, p = 0.019) at baseline were significant predictors of mortality. Among 169 patients who survived for more than 1 year and thus underwent follow-up CGA, CGA domains did not deteriorate during follow-up, except for ADLs. This decline in ADLs during follow-up was the strongest predictor of later nursing home admission (OR 9.29, 95%CI 1.82-47.49, p = 0.007). Higher baseline age (OR per year increase 1.10, 95%CI 1.02-1.20, p = 0.018) and a higher baseline CCI (OR per point increase 1.32, 95%CI 1.05-1.65, p = 0.017) were associated with a decline in ADLs during follow-up. CONCLUSIONS: CGA is useful to detect functional deficits, which are associated with mortality or nursing home admission after pacemaker implantation. The present study seems to support the use of CGA in older patients undergoing pacemaker implantation as functional deficits and falls are amenable to geriatric interventions.


Assuntos
Avaliação Geriátrica , Marca-Passo Artificial , Atividades Cotidianas , Idoso , Humanos , Casas de Saúde , Estudos Prospectivos
14.
Eur Heart J ; 40(26): 2142-2151, 2019 07 01.
Artigo em Inglês | MEDLINE | ID: mdl-31098611

RESUMO

AIMS: We aimed to evaluate the frequency, clinical features, and prognostic implications of cardiac arrest (CA) in takotsubo syndrome (TTS). METHODS AND RESULTS: We reviewed the records of patients with CA and known heart rhythm from the International Takotsubo Registry. The main outcomes were 60-day and 5-year mortality. In addition, predictors of mortality and predictors of CA during the acute TTS phase were assessed. Of 2098 patients, 103 patients with CA and known heart rhythm during CA were included. Compared with patients without CA, CA patients were more likely to be younger, male, and have apical TTS, atrial fibrillation (AF), neurologic comorbidities, physical triggers, and longer corrected QT-interval and lower left ventricular ejection fraction on admission. In all, 57.1% of patients with CA at admission had ventricular fibrillation/tachycardia, while 73.7% of patients with CA in the acute phase had asystole/pulseless electrical activity. Patients with CA showed higher 60-day (40.3% vs. 4.0%, P < 0.001) and 5-year mortality (68.9% vs. 16.7%, P < 0.001) than patients without CA. T-wave inversion and intracranial haemorrhage were independently associated with higher 60-day mortality after CA, whereas female gender was associated with lower 60-day mortality. In the acute phase, CA occurred less frequently in females and more frequently in patients with AF, ST-segment elevation, and higher C-reactive protein on admission. CONCLUSIONS: Cardiac arrest is relatively frequent in TTS and is associated with higher short- and long-term mortality. Clinical and electrocardiographic parameters independently predicted mortality after CA.


Assuntos
Parada Cardíaca/etiologia , Cardiomiopatia de Takotsubo/complicações , Feminino , Parada Cardíaca/diagnóstico , Parada Cardíaca/epidemiologia , Parada Cardíaca/mortalidade , Humanos , Masculino , Pessoa de Meia-Idade , Prognóstico , Sistema de Registros , Estudos Retrospectivos , Análise de Sobrevida
16.
Lancet ; 392(10149): 737-746, 2018 09 01.
Artigo em Inglês | MEDLINE | ID: mdl-30170848

RESUMO

BACKGROUND: Drug-eluting stents combining an ultrathin cobalt-chromium stent platform with a biodegradable polymer eluting sirolimus have been shown to be non-inferior or superior to thin-strut, durable-polymer, everolimus-eluting stents in terms of 1 year safety and efficacy outcomes. METHODS: In the randomised, single-blind, multicentre, non-inferiority BIOSCIENCE trial, we compared biodegradable-polymer sirolimus-eluting stents with durable-polymer everolimus-eluting stents in patients with chronic stable coronary artery disease or acute coronary syndromes. Here, we assess the final 5-year clinical outcomes of BIOSCIENCE with regards to the primary clinical outcome of target lesion failure, which was a composite of cardiac death, target vessel myocardial infarction, and clinically indicated target lesion revascularisation. The primary analysis was done by intention to treat. The BIOSCIENCE trial is registered with ClinicalTrials.gov, number NCT01443104. FINDINGS: 2008 (95%) of 2119 patients recruited between March 1, 2012, and May 31, 2013, completed 5 years of follow-up. Target lesion failure occurred in 198 patients (cumulative incidence 20·2%) treated with biodegradable-polymer sirolimus-eluting stents and in 189 patients (18·8%) treated with durable-polymer everolimus-eluting stents (rate ratio [RR] 1·07, 95% CI 0·88-1·31; p=0·487). All-cause mortality was significantly higher in patients treated with biodegradable-polymer sirolimus-eluting stents than in those treated with durable-polymer everolimus-eluting stents (14·1% vs 10·3%; RR 1·36, 95% CI 1·06-1·75; p=0·017), driven by a difference in non-cardiovascular deaths. We observed no difference between groups in cumulative incidence of definite stent thrombosis at 5 years (1·6% in both groups; 1·02, 0·51-2·05; p=0·950). INTERPRETATION: 5-year risk of target lesion failure among all-comer patients undergoing percutaneous coronary intervention is similar after implantation of ultrathin-strut, biodegradable-polymer, sirolimus-eluting stents or thin-strut, durable-polymer, everolimus-eluting stents. Higher incidences of all-cause and non-cardiovascular mortality in patients treated with biodegradable-polymer stents eluting sirolimus than in those treated with durable-polymer stents eluting everolimus warrant careful observation in ongoing clinical trials. FUNDING: Clinical Trials Unit of the University of Bern and Biotronik.


Assuntos
Síndrome Coronariana Aguda/cirurgia , Doença da Artéria Coronariana/cirurgia , Stents Farmacológicos , Everolimo/administração & dosagem , Imunossupressores/administração & dosagem , Intervenção Coronária Percutânea/instrumentação , Sirolimo/administração & dosagem , Implantes Absorvíveis , Síndrome Coronariana Aguda/complicações , Síndrome Coronariana Aguda/mortalidade , Adulto , Idoso , Idoso de 80 Anos ou mais , Causas de Morte , Doença da Artéria Coronariana/complicações , Doença da Artéria Coronariana/mortalidade , Stents Farmacológicos/efeitos adversos , Feminino , Seguimentos , Humanos , Análise de Intenção de Tratamento , Masculino , Pessoa de Meia-Idade , Infarto do Miocárdio/etiologia , Infarto do Miocárdio/mortalidade , Polímeros , Desenho de Prótese , Falha de Prótese/etiologia , Método Simples-Cego , Trombose/etiologia , Resultado do Tratamento
17.
J Cardiovasc Electrophysiol ; 30(11): 2199-2204, 2019 11.
Artigo em Inglês | MEDLINE | ID: mdl-31424123

RESUMO

INTRODUCTION: The CLOSE protocol combines ablation index (AI) and ≤6 mm interlesion distance using standard power settings for the treatment of atrial fibrillation (AF). The purpose was to compare the safety and efficacy of a conventional CLOSE and a higher power shorter duration (HPSD)-CLOSE pulmonary vein isolation (PVI) strategy. METHODS AND RESULTS: All consecutive patients referred for PVI were included after informed consent was obtained from them. Group 1 was treated with a standard CLOSE protocol and group 2 with a HPSD-CLOSE protocol (45 W anterior and 35 W posterior). Procedural parameters and 6-month follow-up were analyzed. In total, 174 patients (group 1: n = 94 [paroxysmal: n = 74]; group 2: n = 80 [paroxysmal: n = 65], similar baseline characteristics) were included. PVI was reached in all, but procedure duration (82 ± 18 minutes vs 100 ± 22 minutes; P < .0001) and radiofrequency (RF) time (23 ± 5 minutes vs 36 ± 11 minutes; P < .0001) was shorter in group 2. First pass isolation was similar in groups 2 and 1 (left veins: 94% vs 90%; P = .42 and right veins: 83% vs 84%; P = .79, respectively). Six-month off- antiarrhythmic drugs freedom of AF/AT was similar in groups 2 and 1 (82% [paroxysmal: 86%] vs 83% [paroxysmal: 88%]; P = .93, respectively). Major complications were similar (group 2: 1% vs group 1: 3%; P = .39). CONCLUSION: A higher-power short duration approach can shorten a CLOSE procedure and reduce ablation time without having a negative impact on safety or efficiency.


Assuntos
Fibrilação Atrial/cirurgia , Cateteres Cardíacos , Ablação por Cateter/instrumentação , Veias Pulmonares/cirurgia , Potenciais de Ação , Idoso , Antiarrítmicos/uso terapêutico , Fibrilação Atrial/diagnóstico , Fibrilação Atrial/fisiopatologia , Cateterismo Cardíaco/efeitos adversos , Cateterismo Cardíaco/instrumentação , Ablação por Cateter/efeitos adversos , Desenho de Equipamento , Feminino , Frequência Cardíaca , Humanos , Masculino , Pessoa de Meia-Idade , Duração da Cirurgia , Estudos Prospectivos , Veias Pulmonares/fisiopatologia , Recidiva , Fatores de Risco , Fatores de Tempo , Resultado do Tratamento
18.
N Engl J Med ; 373(10): 929-38, 2015 Sep 03.
Artigo em Inglês | MEDLINE | ID: mdl-26332547

RESUMO

BACKGROUND: The natural history, management, and outcome of takotsubo (stress) cardiomyopathy are incompletely understood. METHODS: The International Takotsubo Registry, a consortium of 26 centers in Europe and the United States, was established to investigate clinical features, prognostic predictors, and outcome of takotsubo cardiomyopathy. Patients were compared with age- and sex-matched patients who had an acute coronary syndrome. RESULTS: Of 1750 patients with takotsubo cardiomyopathy, 89.8% were women (mean age, 66.8 years). Emotional triggers were not as common as physical triggers (27.7% vs. 36.0%), and 28.5% of patients had no evident trigger. Among patients with takotsubo cardiomyopathy, as compared with an acute coronary syndrome, rates of neurologic or psychiatric disorders were higher (55.8% vs. 25.7%) and the mean left ventricular ejection fraction was markedly lower (40.7±11.2% vs. 51.5±12.3%) (P<0.001 for both comparisons). Rates of severe in-hospital complications including shock and death were similar in the two groups (P=0.93). Physical triggers, acute neurologic or psychiatric diseases, high troponin levels, and a low ejection fraction on admission were independent predictors for in-hospital complications. During long-term follow-up, the rate of major adverse cardiac and cerebrovascular events was 9.9% per patient-year, and the rate of death was 5.6% per patient-year. CONCLUSIONS: Patients with takotsubo cardiomyopathy had a higher prevalence of neurologic or psychiatric disorders than did those with an acute coronary syndrome. This condition represents an acute heart failure syndrome with substantial morbidity and mortality. (Funded by the Mach-Gaensslen Foundation and others; ClinicalTrials.gov number, NCT01947621.).


Assuntos
Cardiomiopatia de Takotsubo , Síndrome Coronariana Aguda/complicações , Síndrome Coronariana Aguda/diagnóstico por imagem , Idoso , Antagonistas de Receptores de Angiotensina/uso terapêutico , Inibidores da Enzima Conversora de Angiotensina/uso terapêutico , Ecocardiografia , Eletrocardiografia , Feminino , Seguimentos , Ventrículos do Coração/diagnóstico por imagem , Humanos , Estimativa de Kaplan-Meier , Masculino , Pessoa de Meia-Idade , Modelos de Riscos Proporcionais , Sistema de Registros , Estudos Retrospectivos , Cardiomiopatia de Takotsubo/complicações , Cardiomiopatia de Takotsubo/tratamento farmacológico , Cardiomiopatia de Takotsubo/mortalidade , Cardiomiopatia de Takotsubo/fisiopatologia , Função Ventricular Esquerda
20.
Eur Heart J ; 36(45): 3165-77, 2015 Dec 01.
Artigo em Inglês | MEDLINE | ID: mdl-26254178

RESUMO

AIMS: Primary percutaneous coronary intervention (PPCI) is the optimal treatment for patients presenting with ST-elevation myocardial infarction (STEMI). An elevated index of microcirculatory resistance (IMR) reflects microvascular function and when measured after PPCI, it can predict an adverse clinical outcome. We measured coronary microvascular function in STEMI patients and compared sequential changes before and after stent implantation. METHODS AND RESULTS: In 85 STEMI patients, fractional flow reserve, coronary flow reserve, and IMR were measured using a pressure wire (Certus, St Jude Medical, St Paul, MN, USA) immediately before and after stent implantation. Stenting significantly improved all of the measured parameters of coronary physiology including IMR from 67.7 [interquartile range (IQR): 56.2-95.8] to 36.7 (IQR: 22.7-59.5), P < 0.001. However, after stenting, IMR remained elevated (>40) in 28 (32.9%) patients. In 15 of these patients (17.6% of the cohort), only a partial reduction in IMR occurred and these patients were more likely to be late presenters (pain to wire time >6 h). The extent of jeopardized myocardium [standardized beta: -0.26 (IMR unit/Bypass Angioplasty Revascularization Investigation score unit), P: 0.009] and pre-stenting IMR [standardized beta: -0.34 (IMR unit), P: 0.001] predicted a reduction in IMR after stenting (ΔIMR = post-stenting IMR - pre-stenting IMR), whereas thrombotic burden [standardized beta: 0.24 (IMR unit/thrombus score unit), P: 0.01] and deployed stent volume [standardized beta: 0.26 (IMR unit/mm(3) of stent), P: 0.01] were associated with a potentially deleterious increase in IMR. CONCLUSION: Improved perfusion of the myocardium by stent deployment during PPCI is not universal. The causes of impaired microvascular function at the completion of PPCI treatment are heterogeneous, but can reflect a later clinical presentation and/or the location and extent of the thrombotic burden.


Assuntos
Circulação Coronária/fisiologia , Microcirculação/fisiologia , Infarto do Miocárdio/terapia , Intervenção Coronária Percutânea , Stents , Anticoagulantes/uso terapêutico , Trombose Coronária/fisiopatologia , Trombose Coronária/terapia , Quimioterapia Combinada , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Infarto do Miocárdio/fisiopatologia , Revascularização Miocárdica/métodos , Estudos Prospectivos , Resultado do Tratamento , Resistência Vascular/fisiologia
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA