Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 8 de 8
Filtrar
1.
Graefes Arch Clin Exp Ophthalmol ; 259(5): 1365-1373, 2021 May.
Artigo em Inglês | MEDLINE | ID: mdl-33090281

RESUMO

PURPOSE: Comparing two different sutureless scleral fixation techniques. METHODS: A retrospective study of patients who underwent sutureless scleral fixation IOL from October 2013 to May 2018 at "Luigi Sacco Hospital", University of Milan. Comparison between two groups: Group 1 implanted with a 3-piece ALCON-MA60AC and group 2 implanted with a newly developed single-piece foldable IOL SOLEKO FIL-SSF. Patients underwent a complete preoperative ophthalmic assessment and post-operative evaluation at 1, 3, and 6 months. Vitrectomy was performed in all cases. The two groups were compared for age, axial length, and lens status at baseline. Visual acuity, refractive results, surgical time, and post-operative complications were recorded. RESULTS: Thirty-one eyes were included: group 1, 15 eyes of 15 patients, and group 2, 16 eyes of 14 patients. No difference was found in visual acuity. Mean refractive error was 1D in both groups (group 1 1.01D, group 2 1.09D), but spherical equivalent was more often moved toward negative values and induced astigmatism was greater in the 3-piece group (group 1 1.91D [SD ± 2.07], group 2 0.67D [SD ± 0.88] P = 0.04). Surgical procedure was faster in group 2 (mean time difference 21', P = 0.01*). New displacement occurred in 5 cases (33%) of group 1 and in no cases of group 2 (P = 0.01*). Post-operative bleeding was registered only in group 1 (20%), but the difference was not statistically significant. CONCLUSIONS: The group 2 IOL gives in our sample better results due to less post-operative astigmatism and reducing dislocation and bleeding during follow-up. Surgical technique appeared easier and faster: the specifically designed IOL seems to be a feasible solution for sutureless scleral fixation.


Assuntos
Implante de Lente Intraocular , Lentes Intraoculares , Humanos , Estudos Retrospectivos , Esclera/cirurgia , Técnicas de Sutura , Acuidade Visual , Vitrectomia
2.
Ophthalmologica ; 243(5): 334-341, 2020.
Artigo em Inglês | MEDLINE | ID: mdl-31940651

RESUMO

OBJECTIVE: To investigate the influence of the inverted flap technique compared with traditional internal limiting membrane (ILM) peeling in the postoperative remodelling of outer retinal layers of idiopathic macular holes (MHs) >450 µm. METHODS: We analyzed medical records and imaging studies of all patients with an idiopathic MH >450 µm who underwent vitrectomy at the Sacco University Hospital, Milan, and the Sacro Cuore Don Calabria Hospital, Verona, Italy, between January 2008 and December 2017. Out of 41 eyes evaluated, 17 were treated with traditional ILM peeling and 24 with the inverted ILM flap technique. All patients underwent follow-up examinations every 3 months and all of them completed a final visit 12 months after surgery. Best-corrected visual acuity (BCVA) and optical coherence tomography (OCT) parameters were evaluated at each visit. The main outcome measures were the postoperative recovery rate of the external limiting membrane (ELM) and ellipsoid zone (EZ), and postoperative BCVA. Correlations between OCT measurements and visual outcome were analyzed. RESULTS: The ELM recovery rate in the ILM peeling group (15/17 eyes, 88%) was higher than in the ILM flap group (14/24 eyes, 58%) (p = 0.079). The EZ recovery rate was similar in the 2 groups, 7/17 eyes (41%) in the ILM peeling and 8/24 eyes (33%) in the ILM flap group (p = 0.744). Eyes without a persistent hyper-reflective "plug" at the edges of the MH showed a significantly higher EZ recovery rate (11/18, 61%) compared with eyes showing a persistent plug (4/23, 17%) (p = 0.008). The mean BCVA improved significantly in both groups: from 0.93 logMAR (20/170) to 0.26 logMAR (20/36) in the ILM peeling and from 0.98 logMAR (20/190) to 0.37 logMAR (20/46) in the ILM flap group. The final BCVA tended to be better in the ILM peeling group (p = 0.085). CONCLUSIONS: Given the limited information about the influence of ILM flap versus traditional ILM peeling in the postoperative remodelling of large idiopathic MHs, our data provides some new insights into the healing process of MHs >450 µm. This should be considered as part of the decision process about whether to perform an ILM flap in these patients.


Assuntos
Retina/patologia , Perfurações Retinianas/cirurgia , Retalhos Cirúrgicos , Tomografia de Coerência Óptica/métodos , Acuidade Visual , Vitrectomia/métodos , Adulto , Idoso , Idoso de 80 Anos ou mais , Membrana Basal/cirurgia , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Período Pós-Operatório , Perfurações Retinianas/diagnóstico , Estudos Retrospectivos
3.
Graefes Arch Clin Exp Ophthalmol ; 257(12): 2601-2612, 2019 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-31494709

RESUMO

PURPOSE: To describe a distinct vitreomacular interface disorder (VMID) termed Foveal Abnormality associated with epiretinal Tissue of medium reflectivity and Increased blue-light fundus Autofluorescence Signal (FATIAS). METHODS: A case series including forty-seven eyes of 47 patients. The included eyes must present an irregular foveal contour on optical coherence tomography (OCT) and a pathologically increased autofluorescent signal at the fovea on blue-light fundus autofluorescence (B-FAF). Main outcome measures were morphologic characteristics of the lesions, logarithm of minimum angle of resolution (logMAR) best-corrected visual acuity (BCVA), and central foveal thickness (CFT). RESULTS: The following two types of FATIAS were identified: (1) the step type characterized by an asymmetric contour of the foveal pit and by a tissue of medium reflectivity on the foveal surface and (2) the rail type characterized by a shallow foveal pit and a rail of tissue of medium reflectivity on the foveal surface. The outer retinal bands were continuous in all cases. Both types presented with an area of increased B-FAF signal, usually bilobed in the step type and round and centered on the foveal pit in the rail type. LogMAR BCVA was 0.09 ± 0.1 and 0.1 ± 0.1 (P = 0.91), and CFT was 197.8 ± 9.7 and 202.2 ± 13.2 (P = 0.19) in the step and in the rail group, respectively. CONCLUSIONS: We describe a distinct VMID named FATIAS. Two types of FATIAS may be appreciated with SD-OCT and B-FAF analyses, the step and the rail type. Both are characterized by abnormal foveal contour and autofluorescence signal.


Assuntos
Membrana Epirretiniana/complicações , Angiofluoresceinografia/métodos , Fóvea Central/patologia , Perfurações Retinianas/diagnóstico , Tomografia de Coerência Óptica/métodos , Acuidade Visual , Idoso , Idoso de 80 Anos ou mais , Diagnóstico Diferencial , Membrana Epirretiniana/diagnóstico , Feminino , Seguimentos , Fundo de Olho , Humanos , Masculino , Pessoa de Meia-Idade , Perfurações Retinianas/etiologia , Estudos Retrospectivos
4.
Transl Vis Sci Technol ; 12(4): 21, 2023 04 03.
Artigo em Inglês | MEDLINE | ID: mdl-37070937

RESUMO

Purpose: To compare the efficacy of two surgical techniques used to remove silicone oil (SiO) emulsion tamponade after pars plana vitrectomy: triple air-fluid exchange (AFX) and balanced salt solution lavage (BSSL). Methods: X-ray photoemission spectroscopy measured silicon content of the dry residue of fluid samples taken during AFX and BSSL. Ten patients underwent AFX and five BSSL. Three fluid samples were taken per patient, and the dry residue of 10 drops per sample were analyzed. A fluid sample from a patient who never received SiO tamponade was also analyzed to set a "blank" reference sample. Results: Patients' demographics showed no significant difference. Sample 1 of the two groups contained comparable silicon content while samples 2 and 3 of the AFX group contained significantly more silicon than that of the BSSL group (15.0 ± 0.1 and 12.0 ± 0.9 for the AFX group vs. 10.7 ± 1.4 and 5.2 ± 0.6 for the BSSL group, respectively; P < 0.05). The cumulative amount of silicon in the three successive samples was also significantly higher for the AFX group (42.3 ± 1.6 vs. 32 ± 2; P < 0.0001). The average silicon content ratio of consecutive samples was significantly higher for the AFX group compared to the BSSL group (0.90 ± 0.01 vs. 0.58 ± 0.06; P = 0.006). Conclusions: Triple AFX removed more silicon than triple lavage. The eye wall actively interacts with silicon emulsion retaining silicon content rather than behaving as a neutral container. Translational Relevance: Triple air-fluid exchange removed more silicon than BSS lavage. Neither technique behaved as a well-mixed box dilution, suggesting the eye walls actively retain emulsion and a dynamic equilibrium is established between silicon dispersion and the eye wall surface.


Assuntos
Silício , Óleos de Silicone , Humanos , Emulsões , Espectroscopia Fotoeletrônica , Raios X
5.
Am J Ophthalmol Case Rep ; 25: 101273, 2022 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-35136847

RESUMO

PURPOSE: to report a case of Acute Disseminated EncephaloMyelitis (ADEM) occurring after documented SARS-Cov2 infection and flu-like disease. OBSERVATION: A 59-years-old woman presented with progressive visual loss and right leg paresthesia started 6 days earlier when CT scan excluded abnormalities. Visual acuity was OU hand motion with bilateral slow pupillary response and unremarkable ocular extrinsic motility while visual field testing showed diffuse bilateral sensitivity reduction. The patient had also right leg paresthesia and reported a 2-weeks flu-like syndrome 15 days earlier, with nausea, diarrhea, anosmia, ageusia, cough. Brain Magnetic Resonance Imaging revealed bilateral optic nerve enhancement, multiple brain and spine lesions. SARS-CoV-2 PCR tested negative on nasal swab and positive on cerebrospinal fluid. Patient's serum tested positive for anti-SARS-CoV-2 IgG, negative for anti-aquaporin-4 and anti-myelin oligodendrocyte glycoprotein antibodies. A diagnosis of suspect ADEM post SARS-CoV-2 infection was made and treatment with high dose intravenous methylprednisolone (with subsequent prednisone tapering) and immunoglobulins started. Ten days later vision improved to 20/30 RE and 20/25 LE and 3 months later to 20/20. CONCLUSION AND IMPORTANCE: ADEM may ensue after SARS-CoV-2 virus infection. High suspicious index and prompt aggressive treatment may result in complete vision restauration.

6.
J Cataract Refract Surg ; 48(2): 222-229, 2022 Feb 01.
Artigo em Inglês | MEDLINE | ID: mdl-34117178

RESUMO

PURPOSE: To evaluate the influence of anterior capsulorhexis shape, dimension, and eccentricity on intraocular lens (IOL) position. SETTING: Laboratory investigation. DESIGN: Computational model. METHODS: A finite element model of the human crystalline lens capsule and zonule was created and the anterior capsule opened to simulate centered and decentered circular and elliptic rhexis. The model calculated capsular bag stress, IOL rotation, tilt, decentration, and vaulting, related to both capsular landmarks (absolute) and a reference IOL position defined as that obtained with a 5.0 mm circular and centered rhexis. RESULTS: Mean von Mises stress along the IOL major z-axis was significantly higher than that along the perpendicular x-axis in all cases (P < .001), both at the equator and at the rhexis edge. Stress at the equator was always greater than that at the rhexis edge (P < .001) regardless of the rhexis shape and position. As rhexis eccentricity increased, the stress difference between the z- and x-axes increased. Absolute IOL tilt (range 10-1 to 10-7 degrees), decentration (10-3 to 10-7 mm), rotation (10-2 to 10-3 degrees), and vaulting (10-1 mm) were negligible from an optical standpoint, but all of them were significantly greater for decentered rhexis (both round and elliptic) compared with centered (P < .05). CONCLUSIONS: Anterior capsulorhexis irregularity and/or eccentricity increase IOL tilt, decentration, rotation, and vaulting in a numerically significant but optically negligible way. Von Mises stress is much greater at the capsular bag equator compared with the rhexis edge and highly asymmetrically distributed in all cases. Stress asymmetry may influence postoperative biologic processes of capsular bag shrinking and further IOL tilting or decentration.


Assuntos
Cápsula do Cristalino , Lentes Intraoculares , Capsulorrexe , Análise de Elementos Finitos , Humanos , Cápsula do Cristalino/cirurgia , Implante de Lente Intraocular
7.
Transl Vis Sci Technol ; 11(3): 29, 2022 03 02.
Artigo em Inglês | MEDLINE | ID: mdl-35333285

RESUMO

Purpose: To study the dimensions and distribution of human vitreous collagen type II fragments collected after vitrectomy performed at varying cut rates and to evaluate if increasing the cut rate produces smaller collagen fragments, thus reducing retinal traction and/or viscosity. Methods: Fluid was collected during core vitrectomies performed for macular surgery at cut rates from 1000 to 16,000 cuts per minute (CPM) and immediately refrigerated. Protein fractions were separated by molecular weight (MW; >100 kDa, 50-100 kDa, 50-30 kDa, 30-10 kDa, and <10 kDa) through centrifugal filters. The Human Collagen II ELISA Kit colorimetric assay was then used to measure the COL2A1 in unfiltered and filtered samples. Results: Vitreous samples collected after vitrectomy performed at 16,000 CPM contained a higher concentration of protein with MW over 100 kDa than at any other cutting frequency (P < 0.01). No significant differences were found in fractions collected with a MW between 50 and 100 kDa. Collagen type II fragments over 100 kDa were significantly more represented than smaller fragments at each cut rate. The proportion of smaller (50-100 kDa) collagen fragments compared with those over 100 kDa was higher at 2000 CPM than at higher cut rates. Conclusions: Vitreous samples collected at different cut rates do not contain a significantly different proportion of collagen type II fragments of the tested MW. The extreme variability of vitreous flow through the cutter port may explain the uncertain predictability of collagen fragment MWs. Translational Relevance: Increasing the cut rate does not produce vitreous fragments of proportionally smaller dimension. It is necessary to achieve an invariant instantaneous flow through the cutter port in order to decrease retinal traction during vitrectomy.


Assuntos
Vitrectomia , Corpo Vítreo , Colágeno/metabolismo , Colágeno Tipo II/metabolismo , Humanos , Viscosidade , Vitrectomia/métodos , Corpo Vítreo/metabolismo , Corpo Vítreo/cirurgia
8.
BMJ Open Ophthalmol ; 6(1): e000464, 2021.
Artigo em Inglês | MEDLINE | ID: mdl-33501377

RESUMO

OBJECTIVE: To report the results of a global survey on cataract practice patterns related to preoperative, intraoperative and postoperative care, surgical setting and personnel allocation. METHODS AND ANALYSIS: An online 28 questions survey was sent to 240 ophthalmologists asking to describe prevailing trends in their institutions across 38 countries and 5 continents. Questions inquired country, institution, surgical volume and setting, anaesthesia, preoperative and intraoperative examination and postsurgical care. Statistical analysis used crosstabs lambda statistics for non-parametric nominal variables. P value less than 0.05 was considered statistically significant. RESULTS: 209/240 (87%) ophthalmologists responded: 38% representing public hospitals, 36% private practices and 26% academic sites; overall surgical volume was between 241 700 and 410 500 cataracts per year. There was a significant correlation between type of institution and surgical volume. Complete results available in online (https://freeonlinesurveys.com/r/W6BcLLxy). CONCLUSION: Cataract surgery related patterns of perioperative care showed significant difference among respondents, regardless to type of institution, surgical volume and country. Many evidence-based procedures are unevenly practiced around the world and some widespread and expensive habits lack solid scientific evidence while consuming enormous amount of resources both monetary and human. There is a need to reach consensus and share evidence-based practice patterns.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA