RESUMO

PURPOSE OF REVIEW: Augmented reality (AR) has gained popularity in various sectors, including gaming, entertainment, and healthcare. The desire for improved surgical navigation within orthopaedic surgery has led to the evaluation of the feasibility and usability of AR in the operating room (OR). However, the safe and effective use of AR technology in the OR necessitates a proper understanding of its capabilities and limitations. This review aims to describe the fundamental elements of AR, highlight limitations for use within the field of orthopaedic surgery, and discuss potential areas for development. RECENT FINDINGS: To date, studies have demonstrated evidence that AR technology can be used to enhance navigation and performance in orthopaedic procedures. General hardware and software limitations of the technology include the registration process, ergonomics, and battery life. Other limitations are related to the human response factors such as inattentional blindness, which may lead to the inability to see complications within the surgical field. Furthermore, the prolonged use of AR can cause eye strain and headache due to phenomena such as the vergence-convergence conflict. AR technology may prove to be a better alternative to current orthopaedic surgery navigation systems. However, the current limitations should be mitigated to further improve the feasibility and usability of AR in the OR setting. It is important for both non-clinicians and clinicians to work in conjunction to guide the development of future iterations of AR technology and its implementation into the OR workflow.

2.
J Tissue Eng ; 14: 20417314231197282, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-38029018

RESUMO

Female cancer patients who have undergone chemotherapy have an elevated risk of developing ovarian dysfunction and failure. Experimental approaches to treat iatrogenic infertility are evolving rapidly; however, challenges and risks remain that hinder clinical translation. Biomaterials have improved in vitro follicle maturation and in vivo transplantation in mice, but there has only been marginal success for early-stage human follicles. Here, we developed methods to obtain an ovarian-specific extracellular matrix hydrogel to facilitate follicle delivery and establish an in situ ovary (ISO), which offers a permissive environment to enhance follicle survival. We demonstrate sustainable follicle engraftment, natural pregnancy, and the birth of healthy pups after intraovarian microinjection of isolated exogenous follicles into chemotherapy-treated (CTx) mice. Our results confirm that hydrogel-based follicle microinjection could offer a minimally invasive delivery platform to enhance follicle integration for patients post-chemotherapy.

3.
Hand (N Y) ; 17(5): 879-884, 2022 09.
Artigo em Inglês | MEDLINE | ID: mdl-33349049

RESUMO

BACKGROUND: It is recommended to have 6 bicortical screws for plate fixation of long bone fractures; however, many metacarpal fractures do not allow 6 screws due to size limitations and proximity of crucial anatomical structures. The purpose of this biomechanical study was to determine whether the mechanical properties of a 4-screw nonlocking construct are noninferior to those of a 6-screw nonlocking construct. METHODS: Metacarpal sawbones were used to simulate a midshaft, transverse fracture. Nonlocking bicortical screws were placed in the 6-hole plate, and the metacarpals were randomly assigned to 2 equal study groups: (1) 4 screws, 2 on either side of the fracture (4S); and (2) 6 screws, 3 on either side of the fracture (6S). The metacarpals were tested in a cyclic loading mode and load to failure in a cantilever bending mode. RESULTS: Maximum deflection was significantly higher for 4S compared with 6S. Cyclic root mean square (RMS) was also significantly greater for 4S at 70 and 100 N. There were no statistically significant differences observed between the 2 constructs for maximum bending load, bending stiffness, and cyclic RMS at 40 N. The maximum bending load in 4S and 6S was 245.6 ± 37.9 N and 230.8 ± 41.9 N, respectively; 4S was noninferior and not superior to 6S. Noninferiority testing was inconclusive for bending stiffness. CONCLUSIONS: A 4-screw bicortical nonlocking construct is noninferior to a 6-screw bicortical nonlocking construct for fixation of metacarpal fractures, which may be advantageous to minimize disruption of soft tissues while maintaining sufficient construct stability.