1.
Rev Sci Instrum ; 87(5): 053503, 2016 05.
Artigo em Inglês | MEDLINE | ID: mdl-27250419

RESUMO

A new and simple method for determining the degree of dissociation in hydrogen plasmas is presented. In this method, wide-range spectrum covering from an atomic H-γ line (434.05 nm) to molecular Fulcher-α band (600-640 nm) is measured simultaneously by a wide-range miniature spectrometer. Since the wide-range spectrum measured by the miniature spectrometer is too broadened to resolve respective lines in the Fulcher-α band, a synthetic spectrum method is applied to improve the accuracy in the Q-branch of Fulcher-α band intensity measurement. In order to reduce the influence from other transitions or anomalous P- and R-branch of Fulcher-α spectrum, the Fulcher-α spectra of which vibrational states are higher than 1 (υ ≥ 1) are synthesized using the rotational temperature obtained by the 0-0 Fulcher-α spectrum. The degree of dissociation is determined from the intensity ratio between H-γ line and the synthesized Fulcher-α band spectrum. A comparative study carried out in a volume-produced negative hydrogen ion source shows that the degree of dissociation determined by this method agrees well with the measured values using a spectrometer with high spectral resolution. The present method is expected to be useful to characterize the plasma sources with molecular species since it provides important parameters for understanding neutral particle behaviors.

2.
Rev Sci Instrum ; 87(2): 02B117, 2016 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-26931999

RESUMO

The influence of magnetic filter field on plasma properties in the heating region has been investigated in a planar-type inductively coupled radio-frequency (RF) H(-) ion source. Besides filtering high energy electrons near the extraction region, the magnetic filter field is clearly observed to increase the electron temperature in the heating region at low pressure discharge. With increasing the operating pressure, enhancement of electron temperature in the heating region is reduced. The possibility of electron cyclotron resonance (ECR) heating in the heating region due to stray magnetic field generated by a filter magnet located at the extraction region is examined. It is found that ECR heating by RF wave field in the discharge region, where the strength of an axial magnetic field is approximately ∼4.8 G, can effectively heat low energy electrons. Depletion of low energy electrons in the electron energy distribution function measured at the heating region supports the occurrence of ECR heating. The present study suggests that addition of axial magnetic field as small as several G by an external electromagnet or permanent magnets can greatly increase the generation of highly ro-vibrationally excited hydrogen molecules in the heating region, thus improving the performance of H(-) ion generation in volume-produced negative hydrogen ion sources.

3.
Rev Sci Instrum ; 87(2): 02B136, 2016 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-26932018

RESUMO

Transverse magnetic filter field as well as operating pressure is considered to be an important control knob to enhance negative hydrogen ion production via plasma parameter optimization in volume-produced negative hydrogen ion sources. Stronger filter field to reduce electron temperature sufficiently in the extraction region is favorable, but generally known to be limited by electron density drop near the extraction region. In this study, unexpected electron density increase instead of density drop is observed in front of the extraction region when the applied transverse filter field increases monotonically toward the extraction aperture. Measurements of plasma parameters with a movable Langmuir probe indicate that the increased electron density may be caused by low energy electron accumulation in the filter region decreasing perpendicular diffusion coefficients across the increasing filter field. Negative hydrogen ion populations are estimated from the measured profiles of electron temperatures and densities and confirmed to be consistent with laser photo-detachment measurements of the H(-) populations for various filter field strengths and pressures. Enhanced H(-) population near the extraction region due to the increased low energy electrons in the filter region may be utilized to increase negative hydrogen beam currents by moving the extraction position accordingly. This new finding can be used to design efficient H(-) sources with an optimal filtering system by maximizing high energy electron filtering while keeping low energy electrons available in the extraction region.

4.
Rev Sci Instrum ; 87(11): 11E540, 2016 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-27910347

RESUMO

Electron density profiles of versatile experiment spherical torus plasmas are measured by using a hydrogen line intensity ratio method. A fast-frame visible camera with appropriate bandpass filters is used to detect images of Balmer line intensities. The unique optical system makes it possible to take images of Hα and Hß radiation simultaneously, with only one camera. The frame rate is 1000 fps and the spatial resolution of the system is about 0.5 cm. One-dimensional local emissivity profiles have been obtained from the toroidal line of sight with viewing dumps. An initial result for the electron density profile is presented and is in reasonable agreement with values measured by a triple Langmuir probe.

5.
Rev Sci Instrum ; 85(2): 02A508, 2014 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-24593431

RESUMO

Stability of an anode spot plasma, which is an additional high density plasma generated in front of a positively biased electrode immersed in ambient plasma, is a critical issue for its utilization to various types of ion sources. In this study, operating conditions for the generation of stable anode spot plasmas are experimentally investigated. Diagnostics of the bias current flowing into the positively biased electrode and the properties of ambient plasma reveal that unstable nature of the anode spot is deeply associated with the reduction of double layer potential between the anode spot plasma and the ambient plasma. It is found that stability of the anode spot plasma can be improved with increasing the ionization rate in ambient plasma so as to compensate the loss of electrons across the double layer or with enlarging the area of the biased electrode to prevent electron accumulation inside the anode spot. The results obtained from the present study give the guideline for operating conditions of anode spot plasmas as an ion source with high brightness.

6.
Rev Sci Instrum ; 85(2): 02B119, 2014 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-24593559

RESUMO

In a volume-produced negative hydrogen ion source, control of electron temperature is essential due to its close correlation with the generation of highly vibrationally excited hydrogen molecules in the heating region as well as the generation of negative hydrogen ions by dissociative attachment in the extraction region. In this study, geometric effects of the cylindrical discharge chamber on negative ion generation via electron temperature changes are investigated in two discharge chambers with different lengths of 7.5 cm and 11 cm. Measurements with a radio-frequency-compensated Langmuir probe show that the electron temperature in the heating region is significantly increased by reducing the length of the discharge chamber due to the reduced effective plasma size. A particle balance model which is modified to consider the effects of discharge chamber configuration on the plasma parameters explains the variation of the electron temperature with the chamber geometry and gas pressure quite well. Accordingly, H(-) ion density measurement with laser photo-detachment in the short chamber shows a few times increase compared to the longer one at the same heating power depending on gas pressure. However, the increase drops significantly as operating gas pressure decreases, indicating increased electron temperatures in the extraction region degrade dissociative attachment significantly especially in the low pressure regime. It is concluded that the increase of electron temperature by adjusting the discharge chamber geometry is efficient to increase H(-) ion production as long as low electron temperatures are maintained in the extraction region in volume-produced negative hydrogen ion sources.

7.
Rev Sci Instrum ; 83(2): 02B314, 2012 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-22380293

RESUMO

A high monatomic beam fraction is an important factor in a hydrogen ion source to increase the application efficiency. The monatomic fraction of hydrogen plasmas with different plasma electrode materials is measured in a helicon plasma ion source, and aluminum shows the highest value compared to that with the other metals such as copper and molybdenum. Formation of an aluminum oxide layer on the aluminum electrode is determined by XPS analysis, and the alumina layer is verified as the high monatomic fraction. Both experiments and numerical simulations conclude that a low surface recombination coefficient of the alumina layer on the plasma electrode is one of the most important parameters for increasing the monatomic fraction in hydrogen plasma ion sources.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA