Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 3 de 3
Filtrar
Mais filtros

Base de dados
Tipo de documento
Intervalo de ano de publicação
1.
Neurology ; 90(24): e2146-e2154, 2018 06 12.
Artigo em Inglês | MEDLINE | ID: mdl-29752304

RESUMO

OBJECTIVE: To describe the quantification of novel dystrophin production in patients with Duchenne muscular dystrophy (DMD) after long-term treatment with eteplirsen. METHODS: Clinical study 202 was an observational, open-label extension of the randomized, controlled study 201 assessing the safety and efficacy of eteplirsen in patients with DMD with a confirmed mutation in the DMD gene amenable to correction by skipping of exon 51. Patients received once-weekly IV doses of eteplirsen 30 or 50 mg/kg. Upper extremity muscle biopsy samples were collected at combined study week 180, blinded, and assessed for dystrophin-related content by Western blot, Bioquant software measurement of dystrophin-associated immunofluorescence intensity, and percent dystrophin-positive fibers (PDPF). Results were contrasted with matched untreated biopsies from patients with DMD. Reverse transcription PCR followed by Sanger sequencing of newly formed slice junctions was used to confirm the mechanism of action of eteplirsen. RESULTS: Reverse transcription PCR analysis and sequencing of the newly formed splice junction confirmed that 100% of treated patients displayed the expected skipped exon 51 sequence. In treated patients vs untreated controls, Western blot analysis of dystrophin content demonstrated an 11.6-fold increase (p = 0.007), and PDPF analysis demonstrated a 7.4-fold increase (p < 0.001). The PDPF findings were confirmed in a re-examination of the sample (15.5-fold increase, p < 0.001). Dystrophin immunofluorescence intensity was 2.4-fold greater in treated patients than in untreated controls (p < 0.001). CONCLUSION: Taken together, the 4 assays, each based on unique evaluation mechanisms, provided evidence of eteplirsen muscle cell penetration, exon skipping, and induction of novel dystrophin expression. CLASSIFICATION OF EVIDENCE: This study provides Class II evidence of the muscle cell penetration, exon skipping, and induction of novel dystrophin expression by eteplirsen, as confirmed by 4 assays.


Assuntos
Distrofina/biossíntese , Éxons/genética , Morfolinos/uso terapêutico , Distrofia Muscular de Duchenne/tratamento farmacológico , Biópsia , Criança , Humanos , Músculo Esquelético/metabolismo , Músculo Esquelético/patologia , Distrofia Muscular de Duchenne/genética , Distrofia Muscular de Duchenne/metabolismo , Resultado do Tratamento
2.
J Chromatogr Sci ; 41(5): 234-40, 2003.
Artigo em Inglês | MEDLINE | ID: mdl-12841950

RESUMO

A reversed-phase high-performance liquid chromatography method using evaporative light-scattering detection is developed for the determination of residual octylglucoside (OG) levels after a detergent exchange step for in-process samples of a vaccine antigen. The reversed-phase column not only provides separation of the OG but also functions as an extraction column to remove the vaccine antigen from the sample, thereby eliminating off-line sample manipulations. In addition to column selection, the mobile phase is optimized to enhance extraction and separation. The vaccine antigen is irreversibly bound to the column, allowing nonprotein components to interact with the column for separation and elution. The assay is linear over the range of 0.00050-0.050% OG. Precision tested at 0.0010% and 0.0050% OG is 2.9% and 7.2% relative standard deviation, respectively. The limits of quantitation and detection are determined to be 0.00050 and 0.000125% OG, respectively. Accuracy is determined to be 103 and 98%, based on spike recoveries of 0.0010% and 0.0050% OG, respectively.


Assuntos
Cromatografia Líquida de Alta Pressão/métodos , Glucosídeos/isolamento & purificação , Glucosídeos/análise , Luz , Padrões de Referência , Reprodutibilidade dos Testes , Espalhamento de Radiação
3.
Pharm Res ; 22(1): 33-7, 2005 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-15771227

RESUMO

PURPOSE: A chemiluminescent nitrogen detector (CLND) has been evaluated for determining the concentration of an aluminum-adsorbed recombinant vaccine antigen. METHODS: Quantification of the antigen was based upon several nitrogen-containing compounds used to calibrate the CLND. All calibrants (6.75-400 microg/ml) generated linear standard curves, with slopes being directly proportional to the % nitrogen. The limit of quantification (LOQ) was determined to be 6.75 microg/ml based on the performance of the antigen standard curve, and the limit of detection (LOD) was defined by setting the CLND minimum peak area to 40,000 U. The CLND was capable of analyzing antigen-adjuvant suspensions (adsorbed + unbound antigen) without any sample pretreatment. To measure unbound antigen, the suspension was centrifuged and an aliquot of supernatant removed for analysis; the difference between these two measurements was the amount of adsorbed antigen. RESULTS: The adjuvant exhibited no significant matrix effect. Samples were analyzed in triplicate with observed relative standard deviation values ranging from 0.065% to 10.0%. The most accurate concentrations of the antigen were recovered relative to the antigen itself and to glycine as standards. CONCLUSION: This methodology provides a direct measurement of the concentration of a vaccine antigen adsorbed onto an aluminum adjuvant.


Assuntos
Compostos de Alúmen/análise , Antígenos/análise , Medições Luminescentes/métodos , Nitrogênio/análise , Vacinas Sintéticas/análise , Adjuvantes Farmacêuticos/análise , Adjuvantes Farmacêuticos/normas , Adsorção/efeitos dos fármacos , Compostos de Alúmen/administração & dosagem , Compostos de Alúmen/normas , Antígenos/administração & dosagem , Calibragem , Medições Luminescentes/normas , Nitrogênio/normas , Espectrofotometria Ultravioleta/normas , Vacinas Sintéticas/administração & dosagem , Vacinas Sintéticas/normas
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA