Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 43
Filtrar
Mais filtros

Base de dados
País/Região como assunto
Tipo de documento
País de afiliação
Intervalo de ano de publicação
1.
J Vasc Surg ; 68(4): 1217-1224, 2018 10.
Artigo em Inglês | MEDLINE | ID: mdl-29680298

RESUMO

OBJECTIVE: The use of off-the-shelf stent grafts for thoracic endovascular aortic repair of type A dissections is limited by variability in both the length of the ascending aorta and the location of the proximal intimal tear. This experimental study aimed to assess the feasibility of using a physician-modified thoracic aortic stent graft to treat acute type A dissection by a transapical cardiac approach. METHODS: The experiments were performed on six cadaveric human heart, ascending aorta, aortic arch, and descending aorta specimens. Fenestration was fashioned in each standard tubular Valiant thoracic stent graft (Valiant Captivia; Medtronic Vascular, Santa Rosa, Calif) to match the anatomy of each specimen. Stent grafts of sufficient length were selected to cover the entire ascending aorta and aortic arch. Stent graft diameters in proximal sealing zones were oversized by 5% to 10%. The length of the fenestration was the distance between the left subclavian artery and the proximal edge of the origin of the brachiocephalic trunk with an additional 10 mm. The diameter of the scallop was that of the brachiocephalic trunk with an additional 5 mm on all sides. The length of the covered portion of the stent graft was the distance between coronary arteries and the proximal edge of the origin of the brachiocephalic trunk. Two lateral radiopaque markers were positioned to delineate the distal and lateral edge of the scallop. Another 3-cm radiopaque marker was sutured onto the sheath to ensure accurate radiologic positioning of the scallop on the outer curve of the aorta. The left ventricle and the thoracic aorta were connected to a benchtop aortic pulsatile flow model. A 5-mm 30-degree lens was introduced through the left subclavian artery to monitor the procedure. The customized stent graft was deployed by a transapical approach under fluoroscopic control. RESULTS: Median duration of stent graft modification was 21 minutes (range, 17-40 minutes). All attempts to deploy the homemade proximal scalloped stent graft by a transapical approach were successful. Completion angiography demonstrated patency of the supra-aortic trunks and of the coronary arteries in all cases. Macroscopic evaluation did not identify any deterioration of the customized stent graft. CONCLUSIONS: The use of physician-modified stent grafts is feasible for thoracic endovascular aortic repair of type A dissection by a transapical approach in this model.


Assuntos
Aorta Torácica/cirurgia , Aneurisma da Aorta Torácica/cirurgia , Dissecção Aórtica/cirurgia , Implante de Prótese Vascular/instrumentação , Prótese Vascular , Procedimentos Endovasculares/instrumentação , Stents , Idoso , Idoso de 80 Anos ou mais , Dissecção Aórtica/diagnóstico por imagem , Dissecção Aórtica/fisiopatologia , Aorta Torácica/diagnóstico por imagem , Aorta Torácica/fisiopatologia , Aneurisma da Aorta Torácica/diagnóstico por imagem , Aneurisma da Aorta Torácica/fisiopatologia , Aortografia , Implante de Prótese Vascular/métodos , Cadáver , Procedimentos Endovasculares/métodos , Estudos de Viabilidade , Feminino , Humanos , Masculino , Teste de Materiais , Duração da Cirurgia , Desenho de Prótese , Fatores de Tempo , Grau de Desobstrução Vascular
2.
Front Cardiovasc Med ; 10: 1248606, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-38028479

RESUMO

Heart transplantation, the gold standard treatment for end-stage heart failure, is limited by heart graft shortage, justifying expansion of the donor pool. Currently, static cold storage (SCS) of hearts from donations after brainstem death remains the standard practice, but it is usually limited to 240 min. Prolonged cold ischemia and ischemia-reperfusion injury (IRI) have been recognized as major causes of post-transplant graft failure. Continuous ex situ perfusion is a new approach for donor organ management to expand the donor pool and/or increase the utilization rate. Continuous ex situ machine perfusion (MP) can satisfy the metabolic needs of the myocardium, minimizing irreversible ischemic cell damage and cell death. Several hypothermic or normothermic MP methods have been developed and studied, particularly in the preclinical setting, but whether MP is superior to SCS remains controversial. Other approaches seem to be interesting for extending the pool of heart graft donors, such as blocking the paths of apoptosis and necrosis, extracellular vesicle therapy, or donor heart-specific gene therapy. In this systematic review, we summarize the mechanisms involved in IRI during heart transplantation and existing targeting therapies. We also critically evaluate all available data on continuous ex situ perfusion devices for adult donor hearts, highlighting its therapeutic potential and current limitations and shortcomings.

3.
Eur J Cardiothorac Surg ; 62(2)2022 07 11.
Artigo em Inglês | MEDLINE | ID: mdl-35583290

RESUMO

OBJECTIVES: Despite growing evidence that aortic valve repair improves long-term patient outcomes and quality of life, aortic valves are mostly replaced. We evaluate the effect of aortic valve repair versus replacement in patients with dystrophic aortic root aneurysm up to 4 years. METHODS: The multicentric CAVIAAR (Conservation Aortique Valvulaire dans les Insuffisances Aortiques et les Anévrismes de la Racine aortique) prospective cohort study enrolled 261 patients: 130 underwent standardized aortic valve repair (REPAIR) consisting of remodelling root repair with expansible aortic ring annuloplasty, and 131 received mechanical composite valve and graft replacement (REPLACE). Primary outcome was a composite criterion of mortality, reoperation, thromboembolic or major bleeding events, endocarditis or operating site infections, pacemaker implantation and heart failure, analysed with propensity score-weighted Cox model analysis. Secondary outcomes included major adverse valve-related events and components of primary outcome. RESULTS: The mean age was 56.1 years, and valve was bicuspid in 115 patients (44.7%). Up to 4 years, REPAIR did not significantly differ from REPLACE in terms of primary outcome [Hazard Ratio (HR) 0.66 (0.39; 1.12)] but showed significantly less valve-related deaths (HR 0.09 [0.02; 0.34]) and major bleeding events (HR 0.37 [0.16; 0.85]) without an increased risk of valve-related reoperation (HR 2.10 [0.64; 6.96]). When accounting for the occurrence of multiple events in a single patient, the REPAIR group had half the occurrence of major adverse valve-related events (HR 0.51 [0.31; 0.86]). CONCLUSIONS: Although the primary outcome did not significantly differ between the REPAIR and REPLACE groups, the trend is in favour of REPAIR by a significant reduction of valve-related deaths and major bleeding events. Long-term follow-up beyond 4 years is needed to confirm these findings.


Assuntos
Aneurisma Aórtico , Insuficiência da Valva Aórtica , Anuloplastia da Valva Cardíaca , Implante de Prótese de Valva Cardíaca , Humanos , Pessoa de Meia-Idade , Valva Aórtica/cirurgia , Anuloplastia da Valva Cardíaca/efeitos adversos , Aneurisma Aórtico/cirurgia , Estudos Prospectivos , Qualidade de Vida , Resultado do Tratamento , Reoperação/efeitos adversos , Implante de Prótese de Valva Cardíaca/efeitos adversos , Estudos Retrospectivos
4.
Future Sci OA ; 7(4): FSO689, 2021 Feb 15.
Artigo em Inglês | MEDLINE | ID: mdl-33815827

RESUMO

BACKGROUND: Novel oral anticoagulants are used in atrial fibrillation. Idarucizumab has been approved for reversal of dabigatran in situations of life-threatening hemorrhage or emergency surgery. OBJECTIVES: We report a single center experience of ten patients on dabigatran therapy who were given idarucizumab prior to heart transplantation. METHODS & RESULTS: The mean plasma concentration of dabigatran prior to reversal was 139 ± 89 ng/ml. Hemoglobin, hematocrit and platelet levels were decreased after surgery. Surgical procedures were successfully performed with no increased risk, especially regarding bleeding complications. All patients were alive after 90 days. CONCLUSION: Dabigatran reversal with idarucizumab in contexts of emergency surgery/urgent procedures is an attractive and safe option to be taken into consideration for patients with end stage heart disease awaiting transplantation and indication of anticoagulant therapy.

5.
AJR Am J Roentgenol ; 194(3): 574-8, 2010 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-20173130

RESUMO

OBJECTIVE: The purpose of this study was to study the feasibility and diagnostic capability of preoperative cardiac CT for depicting aortic valvular pseudoaneurysms and vegetations in patients referred for aortic endocarditis requiring surgical intervention. MATERIALS AND METHODS: Consecutive patients presenting with active aortic endocarditis requiring surgical intervention were included. CT scan examinations were performed for assessing coronary artery status. Aortic valves were retrospectively analyzed. Contrast-enhanced CT scans were retrospectively gated to the ECG and obtained without the administration of a beta-blocker. The CT and intraoperative findings were systematically compared. RESULTS: During a 4-year period, 19 consecutive patients (18 men and one woman) were included (mean age +/- SD, 55 +/- 13 years). Results are expressed on a per-patient basis. The sensitivity, specificity, positive predictive value, and negative predictive value of MDCT in depicting aortic valve pseudoaneurysms were 100%, 87.5%, 91.7%, and 100%, respectively. The sensitivity, specificity, positive predictive value, and negative predictive value of the MDCT in depicting the extension of the aortic valve pseudoaneurysms into the intervalvular fibrous body were each 100%. The sensitivity, specificity, positive predictive value, and negative predictive value of MDCT in depicting aortic valve vegetations were 71.4%, 100%, 100%, and 55.5%, respectively. The sensitivity, specificity, positive predictive value, and negative predictive value of MDCT for depicting aortic valve vegetations larger than 1 cm were all 100%. CONCLUSION: Our study shows the feasibility of preoperative CT in aortic infective endocarditis for providing relevant data about the presence and relationships of aortic valvular pseudoaneurysms. A larger prospective study including a systematic comparison with transesophageal echocardiography should be performed to determine the respective value of each technique.


Assuntos
Doenças da Aorta/diagnóstico por imagem , Endocardite/diagnóstico por imagem , Tomografia Computadorizada por Raios X/métodos , Aorta Torácica , Doenças da Aorta/cirurgia , Meios de Contraste , Eletrocardiografia , Endocardite/cirurgia , Estudos de Viabilidade , Feminino , Humanos , Iopamidol/análogos & derivados , Masculino , Pessoa de Meia-Idade , Valor Preditivo dos Testes , Cuidados Pré-Operatórios , Interpretação de Imagem Radiográfica Assistida por Computador , Estudos Retrospectivos , Sensibilidade e Especificidade
6.
Pan Afr Med J ; 37: 65, 2020.
Artigo em Inglês | MEDLINE | ID: mdl-33244328

RESUMO

Rupture of Valsalva sinus remains a very rare and deadly complication of Valsalva sinus aneurysm with a high mortality rate. We report here the case of a 47-year-old man who presented to the emergency department with acute exercise-induced dyspnea, chest pain, and fever. Transthoracic (TTE) and transesophageal echocardiography (TEE) highlighted a rupture of the right Valsalva sinus in the right atrium due to infective endocarditis. After stabilization of the patient, a successful surgical repair with double pericardial patches was performed.


Assuntos
Ruptura Aórtica/etiologia , Endocardite/complicações , Seio Aórtico/diagnóstico por imagem , Aneurisma Aórtico/diagnóstico por imagem , Aneurisma Aórtico/etiologia , Ruptura Aórtica/diagnóstico por imagem , Dor no Peito/etiologia , Ecocardiografia , Ecocardiografia Transesofagiana , Átrios do Coração/diagnóstico por imagem , Humanos , Masculino , Pessoa de Meia-Idade
7.
Eur J Cardiothorac Surg ; 34(2): 256-61, 2008 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-18479929

RESUMO

The progress in the surgical treatment of postinfarction left ventricular (LV) aneurysm surgery has reduced the operative mortality considerably, while the selection of the optimal LV repair technique remains unclear. Any of the surgical techniques presented in this review has its own advantages and disadvantages. The main goal of this study was to perform a selective literature review of LV aneurysm repair techniques, the most widespread being the linear repair and patch ventriculoplasty.


Assuntos
Aneurisma Cardíaco/cirurgia , Infarto do Miocárdio/complicações , Aneurisma Cardíaco/etiologia , Ventrículos do Coração/cirurgia , Humanos , Próteses e Implantes , Técnicas de Sutura , Taquicardia Ventricular/cirurgia
8.
Ultrasonics ; 87: 1-6, 2018 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-29427896

RESUMO

Tissue temperature control during cardiac surgery is crucial for myocardial protection. To preserve the tissue, a hypothermic cardioplegia is applied in order to decrease the heart temperature down to around 10°C. The monitoring of the thermal evolution of the myocardium is then of importance to minimize deleterious effects on the heart. The present work aims at evaluating the potential of an ultrasonic velocimetric thermometry on the monitoring of in vitro tissues heating. An indentation process is first proposed to identify the experimental linear relationship linking, in myocardia, the speed of the ultrasonic longitudinal wave to the tissue temperature. An extension of this method based on the echo-tracking principle is then proposed to approach surgical conditions. Temperature changes are measured by monitoring the induced time delays of backscattered ultrasonic echoes. These results are compared to T-type thermocouple reference measurements. They are then discussed in terms of measurement precision and in situ applications.


Assuntos
Coração/fisiologia , Reologia , Termometria/métodos , Ultrassom/métodos , Humanos
9.
10.
Circulation ; 106(12 Suppl 1): I5-10, 2002 Sep 24.
Artigo em Inglês | MEDLINE | ID: mdl-12354700

RESUMO

BACKGROUND: Off-pump coronary artery bypass surgery (OPCAB) has been revived and has gained popularity, although the exact subsets of patients who might benefit most from this technique are unknown. The aim of this retrospective study was to compare the results of coronary artery bypass grafting surgery (CABG) in octogenarians using cardiopulmonary bypass (CPB) or OPCAB techniques. METHODS AND RESULTS: Over a 5-year period (1995-1999), 125 patients older than 80 years of age were operated for isolated myocardial revascularization (63 using CPB and 62 with OPCAB). There was no statistically significant difference in preoperative comorbidities between groups or in mean left ventricular ejection fraction (54.5+/-15.3% in the CPB group and 50.9+/-13.5% in the OPCAB group, respectively). The mean number of distal anastomosis per patient was 2.9 in CPB group and 2.6 in OPCAB group (P=ns). The majority of patients in both groups had unstable angina and were operated on an urgent basis. The operative mortality was 15.9% in the CPB group and 4.8% in the OPCAB group (P=0.04). There were 4 postoperative strokes (6.3%) in the CPB group and none (0%) in the OPCAB group (P=0.04). The percentage of patients transfused was 92.1% in the CPB group and 72.6% in the OPCAB group (P<0.01). Postoperative myocardial infarction occurred in 11.3% in the CPB group and 14.5% in the OPCAB group (P=NS). For all the parameters entered in the multivariate analysis with logistic regression model, the type of surgery (CPB or OPCAB) was an independent predictor of operative mortality and stroke (P=0.0375). The odds ratio (OR) indicates that operative mortality and stroke occur 4 times (OR=4.171) more often in CPB patients than in OPCAB patients. Follow-up showed no significant difference between the 2 groups in terms of cardiac events and mortality. CONCLUSIONS: This retrospective study suggests a benefit of OPCAB in terms of operative mortality and stroke for octogenarian patients when compared with CPB in our institution.


Assuntos
Ponte de Artéria Coronária/instrumentação , Ponte de Artéria Coronária/mortalidade , Acidente Vascular Cerebral/prevenção & controle , Idoso , Idoso de 80 Anos ou mais , Angina Instável/cirurgia , Creatina Quinase/análise , Creatina Quinase Forma MB , Seguimentos , Coração Auxiliar , Humanos , Isoenzimas/análise , Infarto do Miocárdio/epidemiologia , Estudos Retrospectivos , Acidente Vascular Cerebral/epidemiologia , Taxa de Sobrevida , Resultado do Tratamento
11.
Surg Technol Int ; 14: 241-4, 2005.
Artigo em Inglês | MEDLINE | ID: mdl-16525979

RESUMO

This clinical feasibility study was planned to evaluate pericardioscopy as a means of control of the pericardial cavity during drainage for pericardial effusion by a surgical sub xyphoid approach. Seventeen patients who underwent an operation for surgical drainage of the pericardium (11 medical and 6 postoperative pericardial effusions) benefited from a pericardial exploration with a mediastinoscope or rigid thoracoscope (Karl Storz, Germany). In 7 of the 11 medical cases, a severe inflammation of the pericardium associated with false membranes was visualized; in 3 cases, the pericardium was considered as normal; and in 1 case, pericardial metastases were visualized. In the 6 postoperative cases, clots were visualized with a venous bypass graft and the pulmonary cannula of a right ventricular assist device (Thoratec, USA) was also perfectly controlled. The cause of bleeding was reported in one case and suspected in another, but required total sternotomy for repair in both cases. No mortality or morbidity was reported to be directly due to the technique. The peroperative assessment of pericardial cavity is possible by use of pericardioscopy with a satisfactory resolution, but visualization of the left lateral part of the heart remains difficult. The possibility exists to partially remove clots and false membranes, obtain various samples, and control the position of the drains. Improvement in the optic device with the possibility of a flexible device that has a tip protector for optimal visualization, may improve both the technique and results.


Assuntos
Endoscopia , Derrame Pericárdico/cirurgia , Pericardiocentese/instrumentação , Estudos de Viabilidade , Humanos , Esterno/cirurgia , Toracotomia , Resultado do Tratamento
12.
J Thorac Cardiovasc Surg ; 150(1): 136-42, 2015 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-25936469

RESUMO

OBJECTIVE: To assess factors predisposing patients to retrograde type A aortic dissection (RTAD) who have undergone hybrid aortic arch repair. METHODS: From 2001 to 2013, 32 patients underwent hybrid aortic arch repair in our department: 19 in zone 1 and 13 in zone 0. Among these patients, 6 experienced RTAD (18.7%): 3 in zone 0 (23%), 3 in zone 1 (15.8%). Preoperative computed tomography scans of these 32 patients were evaluated. A morphologic assessment of the aortic arch, ascending aorta, and aortic root was performed. Other potential risk factors were investigated. Binary logistic regression was performed to test for possible associations with RTAD. RESULTS: Five patients were successfully converted to open repair. Patients who had RTAD were similar to those who did not, across pertinent variables, including age, type of device, diameter of the ascending aorta, and presence of a bicuspid aortic valve (all P > .1). Incidence of RTAD was observed to be higher among women (P = .034), patients with stent-graft oversizing ≥10% (P = .018), and patients treated with a stent-graft of diameter >42 mm (P = .01). Aortic morphology analysis showed that an indexed aortic diameter of ≥20 mm/m(2) (P = .003); aortic root morphology, specifically loss of the sinotubular junction (P = .004); and presence of an aortic arch malformation (P = .03) were correlated with risk of RTAD. Two patients in the zone-0 group with severe angulation (>120°) between the ascending and the transverse aorta suffered RTAD. CONCLUSIONS: The occurrence of RTAD after hybrid aortic arch repair is common. To prevent this complication, preoperative screening of the aortic arch, ascending aorta, and aortic root morphology is critical.


Assuntos
Aorta Torácica/cirurgia , Doenças da Aorta/epidemiologia , Doenças da Aorta/etiologia , Procedimentos Endovasculares , Complicações Pós-Operatórias/epidemiologia , Complicações Pós-Operatórias/etiologia , Idoso , Idoso de 80 Anos ou mais , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Fatores de Risco
13.
Soins ; (793): 44-6, 2015 Mar.
Artigo em Francês | MEDLINE | ID: mdl-26040141

RESUMO

A coronary artery bypass involves taking blood vessels from another part of the patient's body to bypass one or several major coronary stenoses. Coronary artery bypass using cardiopulmonary bypass and off-pump coronary artery bypass are the two methods used to revascularise the heart after a myocardial infarction.


Assuntos
Ponte de Artéria Coronária/métodos , Ponte Cardiopulmonar , Ponte de Artéria Coronária sem Circulação Extracorpórea , Humanos , Infarto do Miocárdio/terapia
14.
J Thorac Cardiovasc Surg ; 149(2 Suppl): S37-45, 2015 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-25240525

RESUMO

OBJECTIVE: The study objective was to compare the 30-day outcomes of a standardized aortic valve repair technique (REPAIR group) associating root remodeling with an expansible aortic ring annuloplasty versus mechanical composite valve and graft (CVG group) replacement in treating aortic root aneurysms. METHODS: A total of 261 consecutive patients with aortic root aneurysm were enrolled in this multicentric prospective cohort (131 in the CVG group, 130 in the REPAIR group) in 20 centers. The main end point is a composite criterion including mortality; reoperation; thromboembolic, hemorrhagic, or infectious events; and heart failure. Secondary end points were major adverse valve-related events. Crude and propensity score adjusted estimates are provided. RESULTS: The mean age was 56.1 years, and the valve was bicuspid in 115 patients (44.7%). The median (interquartile range) preoperative aortic insufficiency grade was 2.0 (1.0-3.0) in the REPAIR group and 3.0 (2.0-3.0) in the CVG group (P = .0002). Thirty-day mortality was 3.8% (n = 5) in both groups (P = 1.00). Despite a learning curve and longer crossclamp times for valve repair (147.7 vs 99.8 minutes, P < .0001), the 2 groups did not differ significantly for the main criterion (odds ratio, 1.31; 95% confidence interval, 0.72-2.40; P = .38) or 30-day mortality (odds ratio, 0.99; 95% confidence interval, 0.28-3053; P = .99), with a trend toward more frequent major adverse valve-related events in the CVG group (odds ratio, 2.52; 95% confidence interval, 0.86-7.40; P = .09). At discharge, 121 patients (96.8%) in the REPAIR group had grade 0 or 1 aortic insufficiency. CONCLUSIONS: A new standardized approach to valve repair, combining an expansible aortic annuloplasty ring with the remodeling technique, presented similar 30-day results to mechanical CVG with a trend toward reducing major adverse valve-related events. Analysis of late outcomes is in process for 3- and 10-year follow-ups.


Assuntos
Aneurisma Aórtico/cirurgia , Valva Aórtica/anormalidades , Implante de Prótese Vascular , Anuloplastia da Valva Cardíaca , Doenças das Valvas Cardíacas/cirurgia , Implante de Prótese de Valva Cardíaca/instrumentação , Próteses Valvulares Cardíacas , Adulto , Idoso , Idoso de 80 Anos ou mais , Aneurisma Aórtico/diagnóstico , Aneurisma Aórtico/mortalidade , Valva Aórtica/cirurgia , Doença da Válvula Aórtica Bicúspide , Implante de Prótese Vascular/efeitos adversos , Implante de Prótese Vascular/mortalidade , Anuloplastia da Valva Cardíaca/efeitos adversos , Anuloplastia da Valva Cardíaca/mortalidade , Distribuição de Qui-Quadrado , Intervalo Livre de Doença , Feminino , França , Doenças das Valvas Cardíacas/diagnóstico , Doenças das Valvas Cardíacas/mortalidade , Implante de Prótese de Valva Cardíaca/efeitos adversos , Implante de Prótese de Valva Cardíaca/mortalidade , Humanos , Modelos Logísticos , Masculino , Pessoa de Meia-Idade , Análise Multivariada , Razão de Chances , Preferência do Paciente , Complicações Pós-Operatórias/mortalidade , Complicações Pós-Operatórias/cirurgia , Pontuação de Propensão , Estudos Prospectivos , Desenho de Prótese , Reoperação , Fatores de Risco , Fatores de Tempo , Resultado do Tratamento , Adulto Jovem
15.
Ann Thorac Surg ; 75(1): 314-21, 2003 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-12537248

RESUMO

Psychological and psychiatric disorders independently increase the risk of cardiovascular disease and worsen the prognosis in patients with established cardiovascular lesions. The objective of this literature review is to discuss recent data concerning the relationships between depression and anxiety and the outcomes of coronary artery bypass grafting. Pathophysiological hypotheses are put forward to explain observed links. We suggest recommendations aimed at improving the psychological evaluation and management of heart surgery candidates, as well as postbypass patients, in the hope of improving quality of life and cardiovascular outcomes in these patients.


Assuntos
Ansiedade , Ponte de Artéria Coronária/psicologia , Depressão , Ansiedade/etiologia , Depressão/etiologia , Humanos , Fatores de Risco , Resultado do Tratamento
16.
Eur J Cardiothorac Surg ; 23(3): 277-82, 2003 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-12614794

RESUMO

OBJECTIVES: Surgical radiofrequency ablation is increasingly used during open heart surgery for the treatment of chronic atrial fibrillation. The purpose of this study was to determine the effects of application of radiofrequency on coronary endothelial function and structure and establish the relationship between coronary lesions and distance of radiofrequency application. METHODS: Six Landrace swine (25.9+/-2.0 kg) were included in the study. With the heart kept beating, three epicardial radiofrequency lesions (20 W, 20 s duration, 60 degrees C) 2 cm in length each, were created 1, 5 and 10 mm away from the left anterior descending and the right coronary arteries. The circumflex artery served as control. Coronary rings were placed in organ chambers. After contraction to KCl and prostaglandin F2alpha, endothelium-dependent relaxations to bradykinin were studied. Gomori trichrome and hematoxylin-eosin safran staining were used for histological evaluation. RESULTS: Exposure to radiofrequency 1 mm from the coronary arteries caused a significant decrease in endothelium-independent contractions to KCl and endothelium-dependent relaxations to bradykinin compared to controls (P<0.05). No significant decrease of endothelium-dependent relaxations occurred for rings exposed to radiofrequency at a distance of 5 and 10 mm, compared to controls. Histological examination showed endothelial disruption and medial smooth muscle cells at different stages of necrosis up to 5 mm from the radiofrequency application site. CONCLUSIONS: Radiofrequency may induce coronary endothelial functional and morphological damages when applied less than 5 mm from the artery. Caution must be exerted during left atrial radiofrequency application due to the proximity of the circumflex artery.


Assuntos
Fibrilação Atrial/cirurgia , Ablação por Cateter/efeitos adversos , Vasos Coronários/lesões , Endotélio Vascular/lesões , Animais , Vasos Coronários/patologia , Vasos Coronários/fisiopatologia , Endotélio Vascular/patologia , Endotélio Vascular/fisiopatologia , Feminino , Masculino , Músculo Liso Vascular/lesões , Músculo Liso Vascular/patologia , Músculo Liso Vascular/fisiopatologia , Necrose , Técnicas de Cultura de Órgãos , Suínos , Vasoconstrição , Vasodilatação
17.
Can J Cardiol ; 20(14): 1461-5, 2004 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-15614342

RESUMO

BACKGROUND: Patients with diabetes constitute a high-risk population for myocardial revascularization due to extensive coronary disease. OBJECTIVE: To compare the early postoperative outcomes of patients with diabetes undergoing off-pump or on-pump coronary artery bypass surgery. METHODS AND RESULTS: Over a four-year period (1995 to 1998), 885 diabetics were operated for primary isolated coronary bypass; 156 patients had off-pump and 729 had on-pump coronary artery bypass surgery. Patients in the off-pump group were significantly older, had a higher incidence of hypertension and renal failure, and received fewer distal anastomoses (2.7 versus 2.9, P=0.004). Postoperative myocardial infarction, reintubation and postoperative use of intra-aortic balloon pump occurred significantly more frequently in the off-pump group (10.3% versus 5.5%, P=0.04; 8.3% versus 3.6%, P=0.03; 7.7% versus 1.5%, P=0.0001, respectively). Multivariate analysis revealed that type of surgery was an independent predictor of these complications, which occurred 1.9, 2.7 and 7.9 times more often, respectively, in the off-pump group. The 30-day mortality rate was not significantly different between the groups. CONCLUSIONS: Off-pump coronary artery bypass surgery is associated with an increased early postoperative morbidity in patients with diabetes and, thus, should be used with caution.


Assuntos
Ponte de Artéria Coronária/efeitos adversos , Ponte de Artéria Coronária/métodos , Doença das Coronárias/cirurgia , Diabetes Mellitus Tipo 2/diagnóstico , Complicações Pós-Operatórias/epidemiologia , Idoso , Análise de Variância , Ponte Cardiopulmonar/instrumentação , Ponte Cardiopulmonar/métodos , Estudos de Coortes , Intervalos de Confiança , Doença das Coronárias/complicações , Doença das Coronárias/diagnóstico , Doença das Coronárias/mortalidade , Diabetes Mellitus Tipo 2/complicações , Diabetes Mellitus Tipo 2/mortalidade , Feminino , Testes de Função Cardíaca , Mortalidade Hospitalar/tendências , Humanos , Balão Intra-Aórtico/métodos , Masculino , Pessoa de Meia-Idade , Razão de Chances , Probabilidade , Prognóstico , Estudos Prospectivos , Medição de Risco , Índice de Gravidade de Doença , Análise de Sobrevida , Fatores de Tempo , Resultado do Tratamento
18.
Clin Physiol Funct Imaging ; 22(3): 180-6, 2002 May.
Artigo em Inglês | MEDLINE | ID: mdl-12076343

RESUMO

PURPOSE: To validate a newly developed image-processing technique for the assessment of arterial wall compliance and distensibility from non-invasive B-mode ultrasound compared with the invasive wall-tracking technique. MATERIALS AND METHODS: Arterial wall compliance and distensibility coefficient were measured invasively by wall-tracking with an ultrasonic transducer implanted on the vessel wall, and non-invasively by automatic processing of B-mode ultrasound images, with a dedicated workstation and software (IO 3.1, IODP, Paris). Measurements were performed in the normal aorta of five animals, and upstream, at the stent level, and downstream from the stent in eight other animals (immediately after stenting in six, and 3 months later in four), for a total of 35 paired measurements. RESULTS: There was no significant difference between the two techniques for compliance but there was a significant difference in diameter (P<0.005) and distensibility (P<0.05) as external ultrasound measured the inner diameter, while wall-tracking measured the outer diameter. Agreement between the two methods as assessed by the Bland-Altman approach was acceptable for aortic diameter, compliance and distensibility. CONCLUSION: Automatic processing of B-mode ultrasound images is a reliable non-invasive technique to assess the compliance of small-calibre arteries.


Assuntos
Aorta/diagnóstico por imagem , Aorta/fisiologia , Processamento de Imagem Assistida por Computador/normas , Ultrassonografia/normas , Animais , Pressão Sanguínea , Complacência (Medida de Distensibilidade) , Processamento de Imagem Assistida por Computador/métodos , Coelhos , Reprodutibilidade dos Testes , Stents , Ultrassonografia/métodos
19.
Heart Surg Forum ; 7(1): 51-54, 2004 Jan 01.
Artigo em Inglês | MEDLINE | ID: mdl-14980852

RESUMO

Abstract Background: Selective coronary angiography is the standard but invasive procedure for postoperative assessment of coronary artery bypass graft patency. The aim of this prospective study is to evaluate the multislice computed tomography (CT) as a means of postoperative patency assessment and anastomotic site control of arterial and venous coronary bypass grafts performed with off-pump coronary artery bypass techniques. Methods: Over a 6-month period, 20 patients underwent isolated coronary artery bypass (beating heart technique) and benefited, 7 days later, from a patency and anastomotic site control by multidetector angio multislice CT with cardiac gating. Results: Whole internal thoracic artery bypasses and venous grafts were visualized perfectly on their entire length, including the anastomotic site, and 3-dimensional reconstruction was possible. The relationship between cardiac cavities and the bypasses were well visualized, allowing quantification of bypass stenosis ensured by software analysis. Conclusions: Postoperative control of coronary bypasses is possible by multislice CT with a very satisfactory resolution, thus making it possible to check the patency of coronary bypasses and the quality of anastomosis with a noninvasive method. Three-dimensional reconstructions are very useful in the event of redo surgery.

20.
Heart Surg Forum ; 6(3): 160-8, 2003.
Artigo em Inglês | MEDLINE | ID: mdl-12821431

RESUMO

OBJECTIVE: The insertion of intracoronary shunts during off-pump coronary artery bypass surgery may induce severe endothelial dysfunction in the target arteries. The purpose of this study was to determine the role of the ratio of the shunt diameter to the target artery diameter in the development of endothelial dysfunction and to develop guidelines for selecting the most appropriate shunt size. METHODS: Nine swine (25 +/- 4 kg) were used for this study. Three ClearView shunts 3 mm, 2 mm, and 1.25 mm in diameter were inserted proximally to distally via 3 arteriotomies into the right coronary artery to obtain oversizing with the 3-mm shunt, undersizing with the 1.25-mm shunt, and a satisfying congruence with the 2-mm shunt. The shunts were left in place for 15 minutes, and the levels of bleeding were quantified. Coronary rings upstream and downstream from the arteriotomies were then harvested and placed in organ chambers to study endothelium-dependent relaxations to serotonin and bradykinin. Noninstrumented coronary arteries served as controls. RESULTS: A decrease of endothelium-dependent relaxation occurred with the 3-mm shunts (P <.005), which were associated with an adequate hemostasis. A decrease of endotheliumdependent relaxation occurred with the 2-mm shunts (P <.05), which were associated with intermittent bleeding, and no significant decrease of endothelium-dependent relaxation occurred with 1.25-mm shunts (P >.05), which were associated with continuous bleeding. CONCLUSIONS: Intracoronary shunts are associated with different disadvantages, depending on the mismatch to the target coronary artery, and whatever their size, shunts are not the ideal device for safely obtaining a satisfactory hemostasis. These results support our clinical attitude of the selective use of intracoronary shunts.


Assuntos
Ponte de Artéria Coronária/efeitos adversos , Vasos Coronários/fisiopatologia , Endotélio Vascular/fisiopatologia , Relaxamento Muscular/fisiologia , Anastomose Cirúrgica/efeitos adversos , Anastomose Cirúrgica/métodos , Animais , Ponte de Artéria Coronária/métodos , Feminino , Masculino , Modelos Animais , Suínos
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA