Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 65
Filtrar
Mais filtros

País/Região como assunto
Tipo de documento
Intervalo de ano de publicação
1.
Eur Spine J ; 33(6): 2277-2286, 2024 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-38643425

RESUMO

INTRODUCTION: Postoperative cage subsidence after Anterior Cervical Discectomy and Fusion (ACDF) often has adverse clinical consequences and is closely related to Bone Mineral Density (BMD). Previous studies have shown that cage subsidence can be better predicted by measuring site-specific bone density. MRI-based Endplate Bone Quality (EBQ) scoring effectively predicts cage subsidence after lumbar interbody fusion. However, there is still a lack of studies on the practical application of EBQ scoring in the cervical spine. PURPOSE: To create a similar MRI-based scoring system for Cervical-EBQ (C-EBQ) and to assess the correlation of the C-EBQ with endplate Computed Tomography (CT)-Hounsfield Units (HU) and the ability of this scoring system to independently predict cage subsidence after ACDF, comparing the predictive ability of the C-EBQ with the Cervical-Vertebral Bone Quality (C-VBQ) score. METHODS: A total of 161 patients who underwent single-level ACDF for degenerative cervical spondylosis at our institution from 2012 to 2022 were included. Demographics, procedure-related data, and radiological data were collected, and Pearson correlation test was used to determine the correlation between C-EBQ and endplate HU values. Cage subsidence was defined as fusion segment height loss of ≥ 3 mm. Receiver operating characteristic analysis and area-under-the-curve values were used to assess the predictive ability of C-EBQ and C-VBQ. A multivariate logistic regression model was developed to identify potential risk factors associated with subsidence. RESULTS: Cage subsidence was present in 65 (40.4%) of 161 patients. The mean C-EBQ score was 1.81 ± 0.35 in the group without subsidence and 2.59 ± 0.58 in the group with subsidence (P < 0.001). Multivariate analysis showed that a higher C-EBQ score was significantly associated with subsidence (OR = 5.700; 95%CI = 3.435-8.193; P < 0.001), was the only independent predictor of cage subsidence after ACDF, had a predictive accuracy of 93.7%, which was superior to the C-VBQ score (89.2%), and was significantly negatively correlated with the endplate HU value (r = -0.58, P < 0.001). CONCLUSIONS: Higher C-EBQ scores were significantly associated with postoperative cage subsidence after ACDF. There was a significant negative correlation between C-EBQ and endplate HU values. The C-EBQ score may be a promising tool for assessing preoperative bone quality and postoperative cage subsidence and is superior to the C-VBQ.


Assuntos
Vértebras Cervicais , Discotomia , Imageamento por Ressonância Magnética , Fusão Vertebral , Humanos , Fusão Vertebral/instrumentação , Fusão Vertebral/métodos , Vértebras Cervicais/cirurgia , Vértebras Cervicais/diagnóstico por imagem , Discotomia/métodos , Feminino , Pessoa de Meia-Idade , Masculino , Imageamento por Ressonância Magnética/métodos , Idoso , Espondilose/cirurgia , Espondilose/diagnóstico por imagem , Densidade Óssea , Adulto , Estudos Retrospectivos
2.
BMC Musculoskelet Disord ; 25(1): 667, 2024 Aug 26.
Artigo em Inglês | MEDLINE | ID: mdl-39187852

RESUMO

OBJECTIVES: To optimize cervical vertebral bone quality (C-VBQ) score and explore its effectiveness in predicting cage subsidence in Anterior Cervical Corpectomy and Fusion (ACCF) and identify a new method for evaluating subsidence without different equipment and image scale interference. METHODS: Collecting demographic, imaging, and surgical related information. Measuring Cage Subsidence with a new method. Multifactorial logistic regression was used to identify risk factors associated with subsidence. Pearson's correlation was used to determine the relationship between C-VBQ and computed tomography (CT) Hounsfield units (HU). The receiver operating characteristic (ROC) curve was used to assess C-VBQ predictive ability. Correlations between demographics and C-VBQ scores were analyzed using linear regression models. RESULTS: 92 patients were included in this study, 36 (39.1%) showed subsidence with a C-VBQ value of 2.05 ± 0.45, in the no-subsidence group C-VBQ Value was 3.25 ± 0.76. The multifactorial logistic regression showed that C-VBQ is an independent predictor of cage subsidence with a predictive accuracy of 93.4%. Pearson's correlation analysis showed a negative correlation between C-VBQ and HU values. Linear regression analysis showed a positive correlation between C-VBQ and cage subsidence. Univariate analyses showed that only age was associated with C-VBQ. CONCLUSIONS: The C-VBQ values obtained using the new measurements independently predicted postoperative cage subsidence after ACCF and showed a negative correlation with HU values. By adding the measurement of non-operated vertebral heights as a control standard, the results of cage subsidence measured by the ratio method are likely to be more robust, perhaps can exclude unavoidable errors caused by different equipment and proportional.


Assuntos
Vértebras Cervicais , Fusão Vertebral , Humanos , Vértebras Cervicais/cirurgia , Vértebras Cervicais/diagnóstico por imagem , Masculino , Fusão Vertebral/instrumentação , Fusão Vertebral/efeitos adversos , Feminino , Pessoa de Meia-Idade , Idoso , Adulto , Estudos Retrospectivos , Tomografia Computadorizada por Raios X , Valor Preditivo dos Testes , Densidade Óssea , Fatores de Risco , Complicações Pós-Operatórias/etiologia , Complicações Pós-Operatórias/diagnóstico
3.
Appl Energy ; 334: 120676, 2023 Mar 15.
Artigo em Inglês | MEDLINE | ID: mdl-36714219

RESUMO

During the SARS-CoV-2 (COVID-19) pandemic, governments around the world have formulated policies requiring ventilation systems to operate at a higher outdoor fresh air flow rate for a sufficient time, which has led to a sharp increase in building energy consumption. Therefore, it is necessary to identify an energy-efficient ventilation strategy to reduce the risk of infection. In this study, we developed an occupant-number-based model predictive control (OBMPC) algorithm for building ventilation systems. First, we collected the occupancy and Heating, ventilation, and air conditioning system (HVAC) data from March to July 2021. Then, four different models (Auto regression moving average-based multilayer perceptron (ARMA_MLP), Recurrent neural networks (RNN), Long short-term memory networks (LSTM), and Nonhomogeneous Markov with change points detection (NH_Markov)) were used to predict the number of room occupants from 15 min to 24 h ahead with an interval output. We found that each model could predict the number of occupants with 85 % accuracy using a one-person offset. The accuracy of 15 min of the ahead prediction could reach 95 % with a one-person offset, but none of them could track abrupt changes. The occupancy prediction results were used to calculate the ventilation demand using the Wells-Riley equation, and the upper bound can maintain an infection risk lower than 2 % for 93 % of the day. This OBMPC model could reduce the coil load by 52.44 % and shift the peak load by 3 h up to 5 kW compared with 24 × 7 h full outdoor air (OA) system when people wear masks in the space. The occupancy prediction uncertainty could cause a 9 % to 26 % difference in demand ventilation, a 0.3 °C to 2.4 °C difference in zone temperature, a 28.5 % to 44.5 % difference in outdoor airflow rate, and a 10.7 % to 28.2 % difference in coil load.

4.
Build Environ ; 238: 110343, 2023 Jun 15.
Artigo em Inglês | MEDLINE | ID: mdl-37143581

RESUMO

People in cities use elevators daily. With the COVID-19 pandemic, there are more worries about elevator safety, since elevators are often small and crowded. This study used a proven CFD model to see how the virus could spread in elevators. We simulated five people taking in an elevator for 2 min and analyzed the effect of different factors on the amount of virus that could be inhaled, such as the infected person's location, the standing positions of the persons, and the air flow rate. We found that the position of the infected person and the direction they stood greatly impacted virus transmission in the elevator. The use of mechanical ventilation with a flow rate of 30 ACH (air changes per hour) was effective in reducing the risk of infection. In situations where the air flow rate was 3 ACH, we found that the highest number of inhaled virus copies could range from 237 to 1186. However, with a flow rate of 30 ACH, the highest number was reduced to 153 to 509. The study also showed that wearing surgical masks decreased the highest number of inhaled virus copies to 74 to 155.

5.
Indoor Air ; 32(1): e12935, 2022 01.
Artigo em Inglês | MEDLINE | ID: mdl-34605574

RESUMO

COVID-19 has caused the global pandemic and had a serious impact on people's daily lives. The respiratory droplets produced from coughing and talking of an infected patient were possible transmission routes of coronavirus between people. To avoid the infection, the US Centers for Disease Control and Prevention (CDC) advised to wear face masks while maintaining a social distancing of 2 m. Can the social distancing be reduced if people wear masks? To answer this question, we measured the mass of inhaled droplets by a susceptible manikin wearing a mask with different social distances, which was produced by coughing and talking of an index "patient" (human subject) also wearing a mask. We also used the computational fluid dynamics (CFD) technology with a porous media model and particle dispersion model to simulate the transmission of droplets from the patient to the susceptible person with surgical and N95 masks. We compared the CFD results with the measured velocity in the environmental chamber and found that the social distancing could be reduced to 0.5 m when people wearing face masks. In this case, the mass concentration of inhaled particles was less than two people without wearing masks and with a social distancing of 2 m. Hence, when the social distancing was difficult, wearing masks could protect people. We also found that the leakage between the face mask and the human face played an important role in the exhaled airflow pattern and particle dispersion. The verified numerical model can be used for more scenarios with different indoor environments and HVAC systems. The results of this study would make business profitable with reduced social distancing in transportation, education, and entertainment industries, which was beneficial for the reopening of the economy.


Assuntos
Poluição do Ar em Ambientes Fechados , COVID-19 , Máscaras , Distanciamento Físico , Microbiologia do Ar , Movimentos do Ar , COVID-19/prevenção & controle , Humanos , Pandemias , SARS-CoV-2
6.
BMC Musculoskelet Disord ; 23(1): 1113, 2022 Dec 21.
Artigo em Inglês | MEDLINE | ID: mdl-36544134

RESUMO

BACKGROUND: The nanohydroxyapatite/polyamide 66 (n-HA/PA66) cage, a bioactive nonmetal cage, is fabricated in a hollow cylindrical shape and has been widely used for decades with good clinical outcomes for anterior cervical fusion. However, there remain some radiological complications, such as a slightly high subsidence rate. To improve the clinical outcomes, the improved n-HA/PA66 cage now has been developed into a trapezoidal and wedge shape, a better biomechanical shape matching the cervical spine that is similar to that of the PEEK cage. However, there have been no long-term comparisons of the improved n-HA/PA66 cage and PEEK cage in anterior cervical reconstruction. METHODS: Fifty-eight patients who underwent single-level anterior cervical decompression and fusion (ACDF) with the improved n-HA/PA66 cage (n-HA/PA66 group) were matched with patients with the PEEK cage (PEEK group) by clinical presentation, segment, age and sex. All patients underwent a minimum of 6 years of follow-up. The radiographic parameters (cage subsidence, fusion status, cervical lordosis, and segmental sagittal alignment) and clinical parameters (10-point visual analogue scale, Neck Disability Index and Japanese Orthopedic Association scores) from patients were evaluated before surgery, immediately after surgery, and at the latest follow-up. RESULTS: The n-HA/PA66 and PEEK groups were well matched in terms of clinical presentation, segment, age, and sex at surgery. The n-HA/PA66 and PEEK cages had similar fusion rates at 6 months postoperatively (n-HA/PA66: 58.6% vs. PEEK: 51.7%, P = 0.455) and at the last follow-up (n-HA/PA66: 96.6% vs. PEEK: 93.1%, P = 0.402). The respective cage subsidence rates in the n-HA/PA66 and PEEK groups were 6.9 and 12.1% (P = 0.342). The correction of SA was similar between the groups at the final follow-up (n-HA/PA66: 4.29 ± 1.99 vs. PEEK: 3.99 ± 2.59 P = 0.464). There were no significant differences between the two groups in mean cervical lordosis, visual analogue scale scores of the neck and arm, NDI scores, JOA scores or patients' overall satisfaction at the final follow-up. CONCLUSION: After single-level ACDF, the improved n-HA/PA66 cage had similar excellent results in both radiological and clinical outcomes compared with the PEEK cage over 6 years of follow-up. According to these results, the improved n-HA/PA66 cage and the PEEK cage could be comparable for ACDF.


Assuntos
Lordose , Fusão Vertebral , Humanos , Seguimentos , Nylons , Resultado do Tratamento , Lordose/diagnóstico por imagem , Lordose/cirurgia , Estudos Retrospectivos , Fusão Vertebral/métodos , Vértebras Cervicais/diagnóstico por imagem , Vértebras Cervicais/cirurgia , Discotomia/métodos , Polietilenoglicóis , Cetonas
7.
BMC Musculoskelet Disord ; 23(1): 947, 2022 Nov 02.
Artigo em Inglês | MEDLINE | ID: mdl-36324134

RESUMO

BACKGROUND: In clinical practice, there are a significant percentage of Lenke 2 AIS patients suffered from medial shoulder imbalance (MSI) despite achieving good lateral shoulder balance (LSB) following surgery. However, there are few studies evaluating the features of the medial shoulder. The objective of this study was to determine the incidence and independent risk factors of MSI with LSB after Lenke 2 AIS corrective surgery. METHODS: One hundred and twenty Lenke 2 AIS patients with LSB at the last follow-up were reviewed from 2009 to 2018. Preoperative, and 3-month and the last postoperative follow-up radiographs were measured using a number of specific measurements. At the last follow-up, patients were divided into medial shoulder balance (MSB) group and the MSI group according to whether the T1 tilt was greater than 3°. A stepwise multiple linear regression analysis was used to examine the independent risk factors for MSI. Scoliosis Research Society (SRS)-30 questionnaire was used to assess clinical outcomes. RESULTS: Up to 69.2% of patients suffered from MSI with LSB after Lenke Type 2 AIS corrective surgery. Multiple regression showed that postoperative upper instrumented vertebra tilt (UIVt), proximal thoracic curve (PTC), the ratio of PTC and main thoracic curves (PTC/MTC) and T2 vertebra rotation ratio (T2-VR) were significant predictors for MSI (UIVt: b = 0.398, p < 0.001; PTC/MTC: b = 2.085, p < 0.001; PTC: b = 0.155, p < 0.001; T2-VR: b = 3.536, p = 0.008; adjusted R2 = 0.711). 72 patients completed the SRS-30 questionnaire survey, and the MSB group were scored the higher (p ≤ 0.001) in self-image domain (4.18 ± 0.43 vs. 3.70 ± 0.35), satisfaction domain (4.39 ± 0.54 vs. 3.95 ± 0.46) and total average (4.31 ± 0.23 vs. 4.11 ± 0.19). CONCLUSION: Although the patients with Lenke 2 AIS achieve LSB after corrective surgery, up to 69.2% of them suffered from MSI. Postoperative UIVt, PTC, PTC/MTC and T2-VR were significant predictors for MSI. Sufficient correction of these variables may facilitate the achievement of MSB.


Assuntos
Cifose , Escoliose , Fusão Vertebral , Humanos , Adolescente , Escoliose/diagnóstico por imagem , Escoliose/cirurgia , Ombro/diagnóstico por imagem , Ombro/cirurgia , Fusão Vertebral/efeitos adversos , Incidência , Estudos Retrospectivos , Vértebras Torácicas/diagnóstico por imagem , Vértebras Torácicas/cirurgia , Fatores de Risco , Seguimentos
8.
Sheng Wu Yi Xue Gong Cheng Xue Za Zhi ; 39(1): 175-184, 2022 Feb 25.
Artigo em Zh | MEDLINE | ID: mdl-35231979

RESUMO

The body weight support rehabilitation training system has now become an important treatment method for the rehabilitation of lower limb motor dysfunction. In this paper, a pelvic brace body weight support rehabilitation system is proposed, which follows the center of mass height (CoMH) of the human body. It aims to address the problems that the existing pelvic brace body weight support rehabilitation system with constant impedance provides a fixed motion trajectory for the pelvic mechanism during the rehabilitation training and that the patients have low participation in rehabilitation training. The system collectes human lower limb motion information through inertial measurement unit and predicts CoMH through artificial neural network to realize the tracking control of pelvic brace height. The proposed CoMH model was tested through rehabilitation training of hemiplegic patients. The results showed that the range of motion of the hip and knee joints on the affected side of the patient was improved by 25.0% and 31.4%, respectively, and the ratio of swing phase to support phase on the affected side was closer to that of the gait phase on the healthy side, as opposed to the traditional body weight support rehabilitation training model with fixed motion trajectory of pelvic brace. The motion trajectory of the pelvic brace in CoMH mode depends on the current state of the trainer so as to realize the walking training guided by active movement on the healthy side of hemiplegia patients. The strategy of dynamically adjustment of body weight support is more helpful to improve the efficiency of walking rehabilitation training.


Assuntos
Reabilitação do Acidente Vascular Cerebral , Caminhada , Fenômenos Biomecânicos , Marcha , Hemiplegia , Humanos , Pelve , Amplitude de Movimento Articular
9.
Neurosurg Rev ; 44(4): 2299-2308, 2021 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-33097988

RESUMO

The pathophysiology behind the instigation and progression of scoliosis in Chiari malformation type I (CMI) patients has not been elucidated yet. This study aims to explore the initiating and progressive factors for scoliosis secondary to CMI. Pediatric patients with CMI were retrospectively reviewed for radiological characteristics of tonsillar herniation, craniocervical anomaly, syrinx morphology, and scoliosis. Subgroup analyses of the presence of syrinx, scoliosis, and curve progression were also performed. A total of 437 CMI patients were included in the study; 62% of the subjects had syrinx, and 25% had scoliosis. In the subgroup analysis of 272 CMI patients with syrinx, 78 of them (29%) had scoliosis, and multiple logistic regression analysis showed that tonsillar herniation ≥ 10 mm (OR 2.13; P = 0.033) and a clivus canal angle ≤ 130° (OR 1.98; P = 0.025) were independent risk factors for scoliosis. In the subgroup analysis of 165 CMI patients without syrinx, 31 of them (19%) had scoliosis, and multiple logistic regression analysis showed that a clivus canal angle ≤ 130° (OR 3.02; P = 0.029) was an independent risk factor for scoliosis. In the subgroup analysis of curve progression for 97 CMI patients with scoliosis, multiple logistic regression analysis showed that anomalies of the craniocervical junction and syrinx were not risk factors for curve progression. Many complex factors including craniocervical angulation, tonsillar herniation, and syrinx might participate in the instigation of scoliosis for CMI patients, and the relationship between craniocervical angulation and scoliosis deserves further study.


Assuntos
Malformação de Arnold-Chiari , Escoliose , Malformação de Arnold-Chiari/complicações , Malformação de Arnold-Chiari/diagnóstico por imagem , Malformação de Arnold-Chiari/epidemiologia , Humanos , Imageamento por Ressonância Magnética , Estudos Retrospectivos , Fatores de Risco , Escoliose/diagnóstico por imagem , Escoliose/epidemiologia
10.
Pharm Biol ; 59(1): 525-531, 2021 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-33915063

RESUMO

CONTEXT: Thonningianin A is an ellagitannin substance and displays multiple pharmacological activities. OBJECTIVE: This study investigated the pharmacokinetic characteristics of thonningianin A after oral administration in rats using a fully validated liquid chromatography tandem mass spectrometry (LC-MS/MS) method. MATERIALS AND METHODS: A sensitive and selective LC-MS/MS assay was developed for quantifying thonningianin A. Eighteen Wistar rats were randomly divided into three groups (n = 6), which were given at a single dose of 10, 20, or 40 mg/kg thonningianin A by gavage. Blood samples (200 µL) were collected from the orbit vein at designated time points and analyzed using the LC-MS/MS method to measure the levels of thonningianin A. RESULTS: Thonningianin A and internal standard (IS) were eluted at 1.5 and ∼3.0 min, respectively. The selected reaction mode transitions monitored were m/z 873.2 > 300.3 and 819.3 > 610.6 for thonningianin A and the IS, respectively. The calibration range was 10-1200 ng/mL. The intra- and the inter-day accuracy and precision met the acceptance criteria. No carryover and matrix effect were observed. The plasma concentrations of thonningianin A increased rapidly after oral administration of three dosages and reached the mean peak concentrations (Cmax) within 0.61-0.83 h. Meanwhile, AUC0-t/AUC0-∞ of the three dosage groups was more than 89.0% (10 mg/kg), 95.7% (20 mg/kg), and 97.0% (40 mg/kg). DISCUSSION AND CONCLUSIONS: The present method is the first report in terms of the simple precipitation procedure, high sensitivity, and high-throughput efficiency. This validated assay was successfully applied to determine the pharmacokinetic behaviours of thonningianin A in rats. This study should be helpful for providing references for understanding the action mechanism and further application of Penthorum chinense.


Assuntos
Cromatografia Líquida/métodos , Taninos Hidrolisáveis/farmacocinética , Espectrometria de Massas em Tandem/métodos , Administração Oral , Animais , Relação Dose-Resposta a Droga , Taninos Hidrolisáveis/administração & dosagem , Taninos Hidrolisáveis/análise , Ratos , Ratos Wistar
11.
Sheng Wu Yi Xue Gong Cheng Xue Za Zhi ; 38(3): 549-555, 2021 Jun 25.
Artigo em Zh | MEDLINE | ID: mdl-34180201

RESUMO

The rotation center of traditional hip disarticulation prosthesis is often placed in the front and lower part of the socket, which is asymmetric with the rotation center of the healthy hip joint, resulting in poor symmetry between the prosthesis movement and the healthy lower limb movement. Besides, most of the prosthesis are passive joints, which need to rely on the amputee's compensatory hip lifting movement to realize the prosthesis movement, and the same walking movement needs to consume 2-3 times of energy compared with normal people. This paper presents a dynamic hip disarticulation prosthesis (HDPs) based on remote center of mechanism (RCM). Using the double parallelogram design method, taking the minimum size of the mechanism as the objective, the genetic algorithm was used to optimize the size, and the rotation center of the prosthesis was symmetrical with the rotation center of the healthy lower limb. By analyzing the relationship between the torque and angle of hip joint in the process of human walking, the control system mirrored the motion parameters of the lower on the healthy side, and used the parallel drive system to provide assistance for the prosthesis. Based on the established virtual prototype simulation platform of solid works and Adams, the motion simulation of hip disarticulation prosthesis was carried out and the change curve was obtained. Through quantitative comparison with healthy lower limb and traditional prosthesis, the scientificity of the design scheme was analyzed. The results show that the design can achieve the desired effect, and the design scheme is feasible.


Assuntos
Artroplastia de Quadril , Membros Artificiais , Prótese de Quadril , Fenômenos Biomecânicos , Articulação do Quadril , Humanos , Desenho de Prótese , Amplitude de Movimento Articular , Caminhada
12.
Biomed Chromatogr ; 34(1): e4717, 2020 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-31634986

RESUMO

A sensitive ultra-high performance liquid chromatography-tandem mass spectrometry (UHPLC-MS/MS) method was established to analyze furanodienone in rat plasma. In the process of chromatographic separation, selected reaction monitoring transitions for furanodienone and patchouli alcohol (internal standard, IS) were m/z 231.1 → 83.2 and m/z 205.1 → 95.1, respectively. Great linearity of furanodienone in plasma samples was found in the corresponding concentration range (r > 0.995). Intra- and inter-day precisions (RSD, %) were <11.3% in plasma, and the accuracy (RE, %) was within ±10.7%. This method was used to the furanodienone study on rat pharmacokinetics after a single oral dose of 10 mg/kg of furanodiene. The results indicated that the maximum observed plasma concentration was 52.4 ± 19.1 ng/ml at 1.2 ± 0.7 h with an elimination half-life of 2.2 ± 0.7 h. The obtained data indicated that furanodienone could be moderately distributed and eliminated.


Assuntos
Cromatografia Líquida de Alta Pressão/métodos , Furanos/sangue , Sesquiterpenos/sangue , Espectrometria de Massas em Tandem/métodos , Animais , Estabilidade de Medicamentos , Furanos/química , Furanos/farmacocinética , Modelos Lineares , Masculino , Ratos , Ratos Sprague-Dawley , Reprodutibilidade dos Testes , Sensibilidade e Especificidade , Sesquiterpenos/química , Sesquiterpenos/farmacocinética
13.
Biomed Chromatogr ; 33(7): e4516, 2019 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-30811609

RESUMO

The aim of this study was to establish and validate a rapid, selective and reliable ultra-performance liquid chromatography-tandem mass spectrometry (UPLC-MS/MS) for simultaneous quantitations of morin and morusin, and to investigate their pharmacokinetics difference between normal and diabetic rats after oral administration. Plasma samples were pretreated via protein precipitation with acetonitrile. Genkwanin was used as internal standard (IS). Analytes and IS were separated on a Thermo Hypersil Gold C18 column (50 × 4.6 mm, 3 µm) using gradient elution. The mobile phase consisted of acetonitrile and 0.1% formic acid in water at a flow rate of 0.5 mL/min. Mass spectrometry detection was carried out by means of negative electrospray ionization source and multipe-reaction monitoring mode. The transitions of m/z 300.9 → 151.2 for morin, m/z 419.2 → 297.1 for morusin and m/z 283.1 → 268.2 for IS were chosen for quantification. Calibration curves were linear in the range of 1.01-504.2 ng/mL (r2 ≥ 0.99) for morin and 1.02-522.3 ng/mL (r2 ≥ 0.99) for morusin. The lower limit of quantification was 1.02 ng/mL for morin and 1.05 ng/mL for morusin. The extraction recovery was >85.1% for each analyte. No obvious matrix effect was observed under the present UPLC-MS/MS conditions during all of the bioanalysis. The stability study demonstrated that morin and morusin remained stable during the whole analytical procedure. The method was successfully applied to support the pharmacokinetic comparisons of morin and morusin between normal and diabetic rats.


Assuntos
Cromatografia Líquida de Alta Pressão/métodos , Flavonoides/farmacocinética , Espectrometria de Massas em Tandem/métodos , Administração Oral , Animais , Diabetes Mellitus Experimental , Medicamentos de Ervas Chinesas/administração & dosagem , Medicamentos de Ervas Chinesas/farmacocinética , Flavonoides/sangue , Flavonoides/química , Limite de Detecção , Modelos Lineares , Masculino , Morus , Ratos , Ratos Sprague-Dawley , Reprodutibilidade dos Testes
14.
Biomed Chromatogr ; 32(3)2018 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-29027249

RESUMO

Isomers ß-asarone and α-asarone have recently been demonstrated to have differential pharmacological activities. Here, we report an LC-MS/MS method developed using acetonitrile to extract two isomeric phenylpropenes from rat plasma. Separation was achieved using a XDB-C18 column (100 × 2.1 mm; i.d., 1.8 µm) with a mobile phase of methanol-0.1% formic acid (55:45, v/v) at a flow rate of 0.3 mL/min. Calibration curves ranging from 5.20 to 2080 ng/mL for ß-asarone and from 3.68 to 1470 ng/mL for α-asarone were linear (r2 ≥ 0.9938) with the lower limits of quantification being 5.20 and 3.68 ng/mL for both isomers. Intravenous administration of ß-asarone (2.22 mg/kg) and α-asarone (2.36 mg/kg) in rats yielded half-lives of 13.40 ± 4.11 and 28.88 ± 7.82 min with clearance values of 0.196 ± 0.062 mL/min/kg and 0.112 ± 0.012 mL/min/kg for ß-asarone and α-asarone, respectively.


Assuntos
Anisóis/sangue , Anisóis/farmacocinética , Cromatografia Líquida/métodos , Espectrometria de Massas em Tandem/métodos , Derivados de Alilbenzenos , Animais , Anisóis/química , Isomerismo , Modelos Lineares , Masculino , Ratos , Ratos Sprague-Dawley , Reprodutibilidade dos Testes , Sensibilidade e Especificidade
15.
Biomed Chromatogr ; 32(4)2018 04.
Artigo em Inglês | MEDLINE | ID: mdl-29143972

RESUMO

Tubuloside B, a novel neuroprotective phenylethanoid, is a major active constituent of Cistanche tubulosa and Cistanche deserticola. A specific and sensitive liquid chromatography tandem mass spectrometry (LC-MS/MS) method has been developed and validated for the quantification of tubuloside B in rat plasma. Sample preparation was conducted through a protein-precipitation extraction with methanol using tubuloside A as internal standard (IS). Chromatographic separation was achieved using a Capcell Pak C18 column (2.0 × 50 mm, 5 µm) with a mobile phase of methanol-10 mm ammonium acetate buffer (70:30, v/v) in an isocratic elution. Mass spectrometry analysis was performed in negative ionization mode with selected reaction monitoring transitions at m/z 665.1 → 160.9 for tubuloside B, and m/z 827.1 → 160.9 for IS. Calibration curves were linear over the range of 1.64-1640 ng/mL for plasma samples samples (R2 > 0.990). The lower limit of quantification (LLOQ) was 1.64 ng/mL. The intra- and inter-day accuracy was between 92.3 and 113.0% with the RSD <9.23% at all LLOQ and quality control levels. Finally, this method was successfully applied in the pharmacokinetics study of tubuloside B after intravenous administration.


Assuntos
Cromatografia Líquida/métodos , Glucosídeos/sangue , Glucosídeos/farmacocinética , Espectrometria de Massas em Tandem/métodos , Animais , Estabilidade de Medicamentos , Glucosídeos/química , Modelos Lineares , Masculino , Ratos , Ratos Sprague-Dawley , Reprodutibilidade dos Testes , Sensibilidade e Especificidade
16.
Biomed Chromatogr ; 31(12)2017 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-28558153

RESUMO

A sensitive LC-MS method was developed for the quantification of morusin in rat plasma using praeruptorin C as internal standard. After extraction with diethyl ether, post-treatment samples were chromatographed on a Hypersil C18 column. An isocratic mobile phase consisting of methanol-water (70:30, v/v) was applied at a flow rate of 0.4 mL/min. Detection was performed via electrospray ionization source with positive ion mode using selected ion monitoring mode at m/z 443.1 for morusin and m/z 451.0 for IS. Acceptable linearity (r2 ≥ 0.99) was observed over the concentration range of 1.5-800 ng/mL. This method was successfully applied in the pharmacokinetics study of morusin in rats.


Assuntos
Cromatografia Líquida/métodos , Flavonoides/sangue , Flavonoides/farmacocinética , Espectrometria de Massas/métodos , Administração Oral , Animais , Flavonoides/administração & dosagem , Flavonoides/química , Modelos Lineares , Ratos
17.
Sensors (Basel) ; 17(2)2017 Feb 10.
Artigo em Inglês | MEDLINE | ID: mdl-28208587

RESUMO

Detecting vehicles in aerial imagery plays an important role in a wide range of applications. The current vehicle detection methods are mostly based on sliding-window search and handcrafted or shallow-learning-based features, having limited description capability and heavy computational costs. Recently, due to the powerful feature representations, region convolutional neural networks (CNN) based detection methods have achieved state-of-the-art performance in computer vision, especially Faster R-CNN. However, directly using it for vehicle detection in aerial images has many limitations: (1) region proposal network (RPN) in Faster R-CNN has poor performance for accurately locating small-sized vehicles, due to the relatively coarse feature maps; and (2) the classifier after RPN cannot distinguish vehicles and complex backgrounds well. In this study, an improved detection method based on Faster R-CNN is proposed in order to accomplish the two challenges mentioned above. Firstly, to improve the recall, we employ a hyper region proposal network (HRPN) to extract vehicle-like targets with a combination of hierarchical feature maps. Then, we replace the classifier after RPN by a cascade of boosted classifiers to verify the candidate regions, aiming at reducing false detection by negative example mining. We evaluate our method on the Munich vehicle dataset and the collected vehicle dataset, with improvements in accuracy and robustness compared to existing methods.

18.
Biomed Chromatogr ; 30(2): 163-8, 2016 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-26053360

RESUMO

Morinda officinalis is a famous traditional Chinese medicine containing iridoid glycoside compounds, such as monotropein and deacetylasperulosidic acid. The aim of the study was to develop a novel and sensitive liquid chromatography-tandem mass spectrometry (LC/MS/MS) method for the simultaneous determination of the two isomeric iridoid glycosides and then evaluate their pharmacokinetic properties in rats. Selected-reaction monitoring mode was employed for quantification of two analytes in rat plasma. The calibration curves were linear over their respective concentration range with correlation coefficient >0.995 for both analytes. Precision for monotropein and deacetylasperulosidic acid ranged from 2.5 to 11.9% relative standard deviation, and the accuracy of two analytes was -2.0-3.7 and -6.4-10.7% relative error, respectively. This method was successfully applied in pharmacokinetic study after oral administration of M. officinalis extract in rats. The results provided a basis for further research on the bioactivity of M. officinalis.


Assuntos
Cromatografia Líquida/métodos , Glicosídeos/sangue , Glicosídeos Iridoides/sangue , Morinda/química , Espectrometria de Massas em Tandem/métodos , Administração Oral , Animais , Glicosídeos/química , Glicosídeos/farmacocinética , Glicosídeos Iridoides/química , Glicosídeos Iridoides/farmacocinética , Modelos Lineares , Masculino , Extratos Vegetais/administração & dosagem , Raízes de Plantas/química , Ratos , Ratos Sprague-Dawley , Reprodutibilidade dos Testes , Sensibilidade e Especificidade
19.
Bioorg Med Chem Lett ; 24(9): 2159-62, 2014 May 01.
Artigo em Inglês | MEDLINE | ID: mdl-24717151

RESUMO

Two new cucurbitane glycosides, hemslepenside A (1) and 16,25-O-diacetyl-cucurbitacin F-2-O-ß-d-glucopyranoside (3), one new cucurbitacin, 16-O-acetyl-cucurbitacin F (2), along with three known cucurbitane compounds, were isolated from the roots of Hemsleya penxianensis. The structures of 1-6 were established on the basis of extensive spectroscopic and chemical methods. The isolated compounds were evaluated for their cytotoxic activities against different three human cancer cell lines, with IC50 values in the low microgram range.


Assuntos
Antineoplásicos Fitogênicos/química , Antineoplásicos Fitogênicos/farmacologia , Cucurbitaceae/química , Glicosídeos/química , Glicosídeos/farmacologia , Triterpenos/química , Triterpenos/farmacologia , Antineoplásicos Fitogênicos/isolamento & purificação , Linhagem Celular Tumoral , Glicosídeos/isolamento & purificação , Humanos , Neoplasias/tratamento farmacológico , Raízes de Plantas/química , Triterpenos/isolamento & purificação
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA