Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 3 de 3
Filtrar
Mais filtros

Base de dados
País/Região como assunto
Ano de publicação
Tipo de documento
Assunto da revista
País de afiliação
Intervalo de ano de publicação
1.
Egypt Heart J ; 76(1): 83, 2024 Jul 04.
Artigo em Inglês | MEDLINE | ID: mdl-38963642

RESUMO

BACKGROUND: Over recent years, spontaneous coronary artery dissection (SCAD) has emerged as a no longer rare cause of acute coronary syndrome (ACS). On the other hand, coronary artery spasm (CAS) is the main cause of ischemic heart disease with non-obstructive coronary lesions. Clinical manifestations of both vary from stable angina to ACS or, rarely, sudden cardiac death. These entities may be underdiagnosed on a coronary angiography. CASE PRESENTATION: We report the case of a young woman presenting with acute chest pain and no coronary risk factors. Angiography revealed a focal subcritical stenosis of the right coronary artery. Coronary wiring resulted in diffuse and critical spasm. However, optical coherence tomography (OCT) and intravascular ultrasound (IVUS) showed extensive SCAD. She was therefore treated conservatively. On the fourth day, cardiac computed tomography angiography (CCTA) excluded disease progression, and then she was discharged on medical therapy. CONCLUSIONS: Combined IVI plays a vital role in providing accurate and detailed visualization of the coronary anatomy and thus allowing for more precise diagnosis, risk stratification, and treatment planning. CCTA can be considered a valuable tool in the noninvasive follow-up of SCAD.

2.
Diagnostics (Basel) ; 12(4)2022 Mar 25.
Artigo em Inglês | MEDLINE | ID: mdl-35453852

RESUMO

Wellens' syndrome (WS) is a preinfarction state caused by a sub-occlusion of the proximal left anterior descending coronary artery (LAD). In this case report, for the first time, we describe how this syndrome can be caused by COVID-19 infection and, most importantly, that it can be assessed bedside by enhanced transthoracic coronary echo Doppler (E-Doppler TTE). This seasoned technique allows blood flow Doppler to be recorded in the coronaries and at the stenosis site but has never been tested in an acute setting. Two weeks after clinical recovery from bronchitis allegedly caused by COVID-19 infection on the basis of epidemiologic criteria (no swab performed during the acute phase but only during recovery, at which time it was negative), our patient developed typical angina for the first time, mainly during effort but also at rest. He was admitted to our tertiary center, where pharyngeal swabs tested positive for COVID-19. A typical EKG finding supporting WS prompted an assessment of the left main coronary artery (LMCA) and the whole LAD blood flow velocity by E-Doppler TTE. Localized high velocity (transtenotic velocity) (100 cm/s) was recorded in the proximal LAD, with the reference velocity being 20 cm/s. This indicated severe stenosis with 90% area narrowing according to the continuity equation, as confirmed by coronary angiography. During follow-up after successful stenting, E-Doppler TTE showed a decrease in the transtenotic acceleration, confirming stent patency and a normal coronary flow reserve (3.2) and illustrating a normal microcirculatory function. Conclusion: COVID infection can trigger a coronary syndrome like WS. E-Doppler TTE, an ionizing radiation-free method, allows safe and rapid bedside management of the syndrome. This new strategy can be pivotal in distinguishing true WS from pseudo-WS. In cases of pseudo-WS, coronary angiography can be avoided. If E-Doppler TTE confirms the stenosis and PCI (percutaneous coronary intervention) is performed, the same method can allow assessment over time of the precise residual stenosis after stenting and verify the microvasculature status by evaluating coronary flow reserve.

3.
Hellenic J Cardiol ; 68: 9-16, 2022.
Artigo em Inglês | MEDLINE | ID: mdl-35863727

RESUMO

BACKGROUND: Surgical aortic valve replacement with a rapid deployment valve (RDV) is a relatively recent treatment option. The aim of this study was to compare the hemodynamic performance of balloon-expandable (BE)-RDVs and BE-transcatheter heart valves (THVs) in a high surgical risk and frail-elderly population. METHODS: BE-THVs and BE-RDVs were implanted in 138 and 47 patients, respectively, all older than 75 years and with a Canadian Study of Health and Aging category of 5 or above. Echocardiographic assessment was performed at discharge and six months later. RESULTS: At discharge, transprosthetic pressure gradients and indexed effective orifice area (iEOA) were similar in both cohorts. At six-month follow-up, BE-RDVs showed lower peak (14.69 vs. 20.86 mmHg; p < 0.001) and mean (7.82 vs. 11.83 mmHg; p < 0.001) gradients, and larger iEOA (1.05 vs. 0.84 cm2/m2; p < 0.001). Similar findings were also shown considering only small-sized valves. Moderate-to-severe paravalvular leakage was more prevalent in BE-THVs at discharge (14.49 vs. 0.00%; p = 0.032) and, considering exclusively small prostheses, at six months too (57.69 vs. 15.00%; p = 0.014). Nevertheless, BE-THVs determined amelioration in left ventricular ejection fraction (53.79 vs. 60.14%; p < 0.001), pulmonary artery systolic pressure (35.81 vs. 33.15 mmHg; p = 0.042), and tricuspid regurgitation severity (40.58 vs. 19.57%; p = 0.031), from discharge to mid-term follow-up. CONCLUSIONS: BE-RDVs showed better hemodynamic performance, especially when implanted in small annuli. Despite their worse baseline conditions, transcatheter patients still exhibited a greater improvement of their echocardiographic profile at mid-term follow-up.


Assuntos
Estenose da Valva Aórtica , Bioprótese , Próteses Valvulares Cardíacas , Substituição da Valva Aórtica Transcateter , Humanos , Idoso , Estenose da Valva Aórtica/cirurgia , Substituição da Valva Aórtica Transcateter/efeitos adversos , Volume Sistólico , Desenho de Prótese , Resultado do Tratamento , Função Ventricular Esquerda , Canadá/epidemiologia , Valva Aórtica/diagnóstico por imagem , Valva Aórtica/cirurgia , Hemodinâmica
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA