Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 11 de 11
Filtrar
1.
Optom Vis Sci ; 97(9): 669-675, 2020 09.
Artigo em Inglês | MEDLINE | ID: mdl-32932393

RESUMO

SIGNIFICANCE: This randomized, masked, crossover clinical study identifies that ≥125 Dk materials should be used for scleral lens daily wear if disruption to corneal oxygen is to be minimized. PURPOSE: Modern scleral lens use has increased and has proven to be successful where other types and materials have previously failed. Although the required oxygen permeability has been modeled, this has not been established clinically. METHODS: Fifteen masked participants aged 20.7 ± 2.3 years (10 female) were bilaterally fitted with five different scleral lenses (65, 100, 125, 163, and 180+ Dk) of the same shape profile and one soft silicone hydrogel lens compared with no lens wear on separate occasions in a randomized order. A masked researcher measured corneal thickness and fluid reservoir depth, corneal curvature, objective bulbar and limbal redness, corneal biomechanics, and ocular surface oxygen consumption before and after 8 hours of wear. In addition, comfort scores were obtained using a visual analog scale. RESULTS: Scleral lenses with oxygen permeability of 65 Dk resulted in greater corneal thickness (1.37 ± 1.25%) after 8 hours of wear versus ≥100 Dk materials (0.58 ± 0.99%; F = 17.215, P < .001) because of stromal thickening; edema with ≥100 Dk materials was associated with fluid reservoir depth (r = 0.231, P = .05). Fluid reservoir depth decreased similarly with all oxygen-permeable lenses from 325.6 ± 99.1 µm to 174.2 ± 100.8 µm after 8 hours of wear (F = 0.961, P = .44). Oxygen consumption reduced with ≤125 Dk lenses (χ = 604.196, P < .001). Soft and scleral lens wear had no effect on corneal curvature, corneal biomechanics, or ocular hyperemia (P > .05). Soft lenses were more comfortable than all the scleral lenses (P < .05), and the 180+ Dk lenses had the best comfort among the sclerals (P < .05). CONCLUSIONS: A ≥125 Dk is advised for safe scleral lens daily wear. Scleral lens wear leads to an increase in corneal thickness, regardless of lens-material oxygen permeability because of the fluid reservoir depth.


Assuntos
Lentes de Contato , Córnea/fisiologia , Oxigênio/metabolismo , Esclera , Adulto , Lentes de Contato Hidrofílicas , Estudos Cross-Over , Método Duplo-Cego , Feminino , Humanos , Masculino , Consumo de Oxigênio/fisiologia , Permeabilidade , Adulto Jovem
2.
J Refract Surg ; 30(9): 584-8, 2014 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-25250414

RESUMO

PURPOSE: To assess the visual performance and subjective experience of eyes implanted with a new bi-aspheric, segmented, multifocal intraocular lens: the Mplus X (Topcon Europe Medical, Capelle aan den IJssel, Netherlands). METHODS: Seventeen patients (mean age: 64.0 + 12.8 years) had binocular implantation (34 eyes) with the Mplus X. Three months after the implantation, assessment was made of: manifest refraction; uncorrected and corrected distance visual acuity; uncorrected and distance corrected near visual acuity; defocus curves in photopic conditions; contrast sensitivity; halometry as an objective measure of glare; and patient satisfaction with unaided near vision using the Near Acuity Visual Questionnaire. RESULTS: Mean residual manifest refraction was -0.13 + 0.51 diopters (D). Twenty-five eyes (74%) were within a mean spherical equivalent of -0.50 D. Mean uncorrected distance visual acuity was +0.10 + 0.12 logMAR monocularly and 0.02 - 0.09 IogMAR binocularly. Thirty-two eyes (94%) could read 0.3 or better without any reading correction and all patients could read 0.3 or better with a reading correction. Mean monocular uncorrected near visual acuity was 0.18 + 0.16 logMAR, improving to 0.15 + 0.15 logMAR with distance correction. Mean binocular uncorrected near visual acuity was 0.11 - 0.11 logMAR, improving to 0.09 - 0.12 logMAR with distance correction. Mean binocular contrast sensitivity was 1.75 _ 0.14 log units at 3 cycles per degree, 1.88 _ 0.20 log units at 6 cycles per degree, 1.66 + 0.19 log units at 12 cycles per degree, and 1.11 - 0.20 log units at 18 cycles per degree. Mean binocular and monocular halometry showed a glare profile of less than 10 of debilitating light scatter. Mean Near Acuity Visual Questionnaire Rasch score (0 = no difficulty, 100 = extreme difficulty) for satisfaction for near vision was 20.43 - 14.64 log-odd units. CONCLUSIONS: The Mplus X provides a good visual outcome at distance and near with minimal dysphotopsia. Patients were very satisfied with their uncorrected near vision.


Assuntos
Implante de Lente Intraocular , Lentes Intraoculares , Satisfação do Paciente , Facoemulsificação , Refração Ocular/fisiologia , Acuidade Visual/fisiologia , Adulto , Idoso , Idoso de 80 Anos ou mais , Sensibilidades de Contraste/fisiologia , Percepção de Profundidade/fisiologia , Feminino , Ofuscação , Humanos , Masculino , Pessoa de Meia-Idade , Estudos Prospectivos , Visão Binocular/fisiologia
3.
Cont Lens Anterior Eye ; 45(6): 101593, 2022 12.
Artigo em Inglês | MEDLINE | ID: mdl-35431131

RESUMO

PURPOSE: To examine the effects of long-term ultraviolet radiation (UVR) blocking wearing contact lenses on ocular surface health, eye focus and macular pigment. METHOD: 210 pre-presbyopic patients were recruited from Birmingham UK, Brisbane Australia, Hong Kong China, Houston USA and Waterloo Canada (n = 42 at each site). All patients had worn contact lenses for ≥ 5 years, half (test group) of a material incorporating a UVR-blocking filter. Ocular health was assessed using slit-lamp biomicroscopy and UV autofluorescence. Accommodation was measured subjectively with a push-up test and overcoming lens-induced defocus. Objective stimulus response and dynamic measures of the accommodative response were quantified with an open-field aberrometer. Macular pigment optical density (MPOD) was assessed using heterochromatic flicker photometry (MPS II). RESULTS: The two groups of participants were matched for age, sex, race, body-mass-index, diet, lifestyle, UVR exposure, refractive error and visual acuity. Limbal (p = 0.035), but not bulbar conjunctival redness (p = 0.903) was lower in eyes that had worn UVR-blocking contact lenses compared to controls. The subjective (8.0 ± 3.7D vs 7.3 ± 3.3D; p = 0.125) and objective (F = 1.255, p = 0.285) accommodative response was higher in the test group, but the differences did not reach significance. However, the accommodative latency was shorter in eyes that had worn UVR-blocking contact lenses (p = 0.003). There was no significant different in MPOD with UVR filtration (p = 0.869). CONCLUSIONS: Blocking the transmission of UVR is beneficial in maintaining the eye's ability to focus, suggesting that presbyopia maybe delayed in long-term UVR-blocking contact lenses wearers. These lenses also provide protection to the critical limbal region.


Assuntos
Lentes de Contato , Pigmento Macular , Proteção Radiológica , Humanos , Raios Ultravioleta , Olho/efeitos da radiação
4.
Ocul Surf ; 21: 58-63, 2021 07.
Artigo em Inglês | MEDLINE | ID: mdl-33965652

RESUMO

PURPOSE: To evaluate demographic and lifestyle factors associated with aqueous deficient and evaporative dry eye disease. METHODS: A total of 1125 general public visitors (707 females, mean ± SD age, 33 ± 21, range 5-90 years) at the Royal Society Summer Science Exhibition were recruited in a cross-sectional study. A demographic and lifestyle factor questionnaire was administered, and dry eye symptomology (DEQ-5 score), ocular surface characteristics (conjunctival hyperaemia, and infrared meibography), and tear film parameters (tear meniscus height, non-invasive breakup time, and lipid layer grade) were evaluated for the left eye of each participant within a single session. The diagnostic criteria for dry eye disease subtypes were adapted from the rapid non-invasive dry eye assessment algorithm. RESULTS: Overall, 428 (38%) participants fulfilled the diagnostic criteria for dry eye disease, 161 (14%) with aqueous deficient dry eye disease, and 339 (30%) with evaporative dry eye disease. Multivariate logistic regression demonstrated that advancing age, female sex, reduced sleep duration, higher psychological stress, and poorer self-perceived health status were independently associated with aqueous deficient dry eye disease (all p < 0.05). Significant risk factors for evaporative dry eye disease included advancing age, East and South Asian ethnicity, contact lens wear, increased digital device screen exposure, higher psychological stress, and poorer self-perceived health status (all p < 0.05). CONCLUSIONS: Both subtypes of dry eye disease were associated with several unique and shared demographic and lifestyle factors. The findings of this study could inform future research design investigating the utility of targeted screening and risk factor modification for the prevention and management of dry eye disease.


Assuntos
Síndromes do Olho Seco , Glândulas Tarsais , Adolescente , Adulto , Idoso , Idoso de 80 Anos ou mais , Criança , Pré-Escolar , Estudos Transversais , Demografia , Síndromes do Olho Seco/epidemiologia , Feminino , Humanos , Estilo de Vida , Pessoa de Meia-Idade , Fatores de Risco , Lágrimas , Adulto Jovem
5.
Vision (Basel) ; 3(3)2019 Jun 28.
Artigo em Inglês | MEDLINE | ID: mdl-31735835

RESUMO

The key determinants of the range of clear focus in pre-presbyopes and their relative contributions to the difference between subjective range of focus and objective accommodation assessments have not been previously quantified. Fifty participants (aged 33.0 ± 6.4 years) underwent simultaneous monocular subjective (visual acuity measured with an electronic test-chart) and objective (dynamic accommodation measured with an Aston open-field aberrometer) defocus curve testing for lenses between +2.00 to -10.00 DS in +0.50 DS steps in a randomized order. Pupil diameter and ocular aberrations (converted to visual metrics normalized for pupil size) at each level of blur were measured. The difference between objective range over which the power of the crystalline lens changes and the subjective range of clear focus was quantified and the results modelled using pupil size, refractive error, tolerance to blur, and ocular aberrations. The subjective range of clear focus was principally accounted for by age (46.4%) and pupil size (19.3%). The objectively assessed accommodative range was also principally accounted for by age (27.6%) and pupil size (15.4%). Over one-quarter (26.0%) of the difference between objective accommodation and subjective range of clear focus was accounted for by age (14.0%) and spherical aberration at maximum accommodation (12.0%). There was no significant change in the objective accommodative response (F = 1.426, p = 0.229) or pupil size (F = 0.799, p = 0.554) of participants for levels of defocus above their amplitude of accommodation. Pre-presbyopes benefit from an increased subjective range of clear vision beyond their objective accommodation due in part to neural factors, resulting in a measured depth-of-focus of, on average, 1.0 D.

6.
Am J Ophthalmol ; 205: 165-174, 2019 09.
Artigo em Inglês | MEDLINE | ID: mdl-31078533

RESUMO

PURPOSE: To compare routine clinical examination with optical coherence tomography angiography (OCTA) for the assessment of limbal conjunctival ischemia following a chemical burn. SETTING: Validity analysis. METHODS: We assessed 10 participants (15 eyes) with an acute chemical injury. Clinical photographs were used to determine the extent of any limbal conjunctival epithelial defect and ischemia. These were compared with the extent of limbal ischemia identified on OCTA images of the ocular surface. Quantitative and longitudinal analysis using the OCTA software were also performed. Correlations with visual outcome were sought using clinical and OCTA-derived variables. RESULTS: The extent of clinically determined limbal ischemia was less than that identified with OCTA (2.3±3.6 clock hours vs 5.1±4.2 clock hours, P = .003), which in turn was less than the size of limbal conjunctival epithelial defect (7.3±5.1 clock hours, P = .03). Longitudinal OCTA analysis showed that mean vessel area increased by 0.2%±0.1% during the study, corresponding to a rate of vascular recovery of 0.9 mm2/d. Significant correlations were found between visual outcome at 3 months and limbal conjunctival fluorescein staining (r = 0.67, P = .006), and limbal conjunctival ischemia on OCTA (r = 0.76, P = .001). CONCLUSIONS: OCTA can objectively identify and monitor the recovery of limbal ischemia following an acute ocular chemical injury. OCTA confirms that limbal ischemia is usually more extensive than is suggested by clinical examination, and the former is highly correlated with visual outcome. OCTA therefore is a useful tool in the management of ocular chemical injury.


Assuntos
Segmento Anterior do Olho/patologia , Queimaduras Químicas/diagnóstico , Traumatismos Oculares/diagnóstico , Angiofluoresceinografia/métodos , Tomografia de Coerência Óptica/métodos , Acuidade Visual , Doença Aguda , Adulto , Feminino , Seguimentos , Fundo de Olho , Humanos , Masculino , Estudos Prospectivos
9.
BMJ Open ; 6(7): e012078, 2016 07 27.
Artigo em Inglês | MEDLINE | ID: mdl-27466243

RESUMO

OBJECTIVES: To describe the initial outcomes following installation of a cataract surgery laser system. SETTING: National Health Service cataract surgery day care unit in North London, UK. PARTICIPANTS: 158 eyes of 150 patients undergoing laser-assisted cataract surgery. INTERVENTIONS: Laser cataract surgery using the AMO Catalys femtosecond laser platform. PRIMARY OUTCOME MEASURE: intraoperative complications including anterior and posterior capsule tears. SECONDARY OUTCOME MEASURES: docking to the laser platform, successful treatment delivery, postoperative visual acuities. RESULTS: Mean case age was 67.7±10.8 years (range 29-88 years). Docking was successful in 94% (148/158 cases), and in 4% (6/148 cases) of these, the laser delivery was aborted part way during delivery due to patient movement. A total of 32 surgeons, of grades from junior trainee to consultant, performed the surgeries. Median case number per surgeon was 3 (range from 1-20). The anterior capsulotomy was complete in 99.3% of cases, there were no anterior capsule tears (0%). There were 3 cases with posterior capsule rupture requiring anterior vitrectomy, and 1 with zonular dialysis requiring anterior vitrectomy (4/148 eyes, 2.7%). These 4 cases were performed by trainee surgeons, and were either their first laser cataract surgery (2 surgeons) or their first and second laser cataract surgeries (1 surgeon). CONCLUSIONS: Despite the learning curve, docking and laser delivery were successfully performed in almost all cases, and surgical complication rates and visual outcomes were similar to those expected based on national data. Complications were predominately confined to trainee surgeons, and with the exception of intraoperative pupil constriction appeared unrelated to the laser-performed steps.


Assuntos
Procedimentos Cirúrgicos Ambulatórios/estatística & dados numéricos , Extração de Catarata/métodos , Terapia a Laser/métodos , Adulto , Idoso , Idoso de 80 Anos ou mais , Extração de Catarata/efeitos adversos , Extração de Catarata/normas , Feminino , Humanos , Complicações Intraoperatórias/prevenção & controle , Terapia a Laser/efeitos adversos , Terapia a Laser/normas , Londres , Masculino , Pessoa de Meia-Idade , Oftalmologia/educação , Estudos Retrospectivos , Medicina Estatal
10.
Cont Lens Anterior Eye ; 37(3): 191-5, 2014 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-24275625

RESUMO

PURPOSE: Evaluating the impact of splitting toric power on patient tolerance to misorientation such as with intraocular lens rotation. SETTING: University vision clinic. METHODS: Healthy, non astigmats had +1.50D astigmatism induced with spectacle lenses at 90°, 135°, 180° and +3.00D at 90°. Two correcting cylindrical lenses of the opposite sign and half the power each were subsequently added to the trial frame misaligned by 0°, 5° or 10° in a random order and misorientated from the initial axis in a clockwise direction by up to 15° in 5° steps. A second group of adapted astigmats with between 1.00 and 3.00DC had their astigmatism corrected with two toric spectacle lenses of half the power separated by 0°, 5° or 10° and misorientated from the initial axis in both directions by up to 15° in 5° steps. Distance, high contrast visual acuity was measured using a computerised test chart at each lens misalignment and misorientation. RESULTS: Misorientation of the split toric lenses caused a statistically significant drop in visual acuity (F=70.341; p<0.001). Comparatively better acuities were observed around 180°, as anticipated (F=3.775; p=0.035). Misaligning the split toric power produced no benefit in visual acuity retention with axis misorientation when subjects had astigmatism induced with a low (F=2.190, p=0.129) or high cylinder (F=0.491, p=0.617) or in the adapted astigmats (F=0.120, p=0.887). CONCLUSION: Misalignment of toric lens power split across the front and back lens surfaces had no beneficial effect on distance visual acuity, but also no negative effect.


Assuntos
Astigmatismo/diagnóstico , Astigmatismo/etiologia , Implante de Lente Intraocular/efeitos adversos , Lentes Intraoculares/efeitos adversos , Satisfação do Paciente , Ajuste de Prótese/efeitos adversos , Adulto , Astigmatismo/prevenção & controle , Feminino , Humanos , Masculino , Resultado do Tratamento
11.
Invest Ophthalmol Vis Sci ; 54(9): 6190-7, 2013 Sep 11.
Artigo em Inglês | MEDLINE | ID: mdl-23942975

RESUMO

PURPOSE: To evaluate the influence of soft contact lens midperipheral shape profile and edge design on the apparent epithelial thickness and indentation of the ocular surface with lens movement. METHODS: Four soft contact lens designs comprising of two different plano midperipheral shape profiles and two edge designs (chiseled and knife edge) of silicone-hydrogel material were examined in 26 subjects aged 24.7 ± 4.6 years, each worn bilaterally in randomized order. Lens movement was imaged enface on insertion, at 2 and 4 hours with a high-speed, high-resolution camera simultaneous to the cross-section of the edge of the contact lens interaction with the ocular surface captured using optical coherence tomography (OCT) nasally, temporally, and inferiorly. Optical imaging distortions were individually corrected for by imaging the apparent distortion of a glass slide surface by the removed lens. RESULTS: Apparent epithelial thickness varied with edge position (P < 0.001). When distortion was corrected for, epithelial indentation decreased with time after insertion (P = 0.010), changed after a blink (P < 0.001), and varied with position on the lens edge (P < 0.001), with the latter being affected by midperipheral lens shape profile and edge design. Horizontal and vertical lens movement did not change with time postinsertion. Vertical motion was affected by midperipheral lens shape profile (P < 0.001) and edge design (P < 0.001). Lens movement was associated with physiologic epithelium thickness for lens midperipheral shape profile and edge designs. CONCLUSIONS: Dynamic OCT coupled with high-resolution video demonstrated that soft contact lens movement and image-corrected ocular surface indentation were influenced by both lens edge design and midperipheral lens shape profiles.


Assuntos
Lentes de Contato Hidrofílicas , Epitélio Corneano/anatomia & histologia , Desenho de Prótese , Adulto , Estudos Cross-Over , Feminino , Humanos , Masculino , Tomografia de Coerência Óptica , Adulto Jovem
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA