Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 13 de 13
Filtrar
1.
Phys Rev Lett ; 127(15): 151301, 2021 Oct 08.
Artigo em Inglês | MEDLINE | ID: mdl-34678017

RESUMO

We present results from an analysis of all data taken by the BICEP2, Keck Array, and BICEP3 CMB polarization experiments up to and including the 2018 observing season. We add additional Keck Array observations at 220 GHz and BICEP3 observations at 95 GHz to the previous 95/150/220 GHz dataset. The Q/U maps now reach depths of 2.8, 2.8, and 8.8 µK_{CMB} arcmin at 95, 150, and 220 GHz, respectively, over an effective area of ≈600 square degrees at 95 GHz and ≈400 square degrees at 150 and 220 GHz. The 220 GHz maps now achieve a signal-to-noise ratio on polarized dust emission exceeding that of Planck at 353 GHz. We take auto- and cross-spectra between these maps and publicly available WMAP and Planck maps at frequencies from 23 to 353 GHz and evaluate the joint likelihood of the spectra versus a multicomponent model of lensed ΛCDM+r+dust+synchrotron+noise. The foreground model has seven parameters, and no longer requires a prior on the frequency spectral index of the dust emission taken from measurements on other regions of the sky. This model is an adequate description of the data at the current noise levels. The likelihood analysis yields the constraint r_{0.05}<0.036 at 95% confidence. Running maximum likelihood search on simulations we obtain unbiased results and find that σ(r)=0.009. These are the strongest constraints to date on primordial gravitational waves.

2.
Appl Opt ; 59(10): 3285-3295, 2020 Apr 01.
Artigo em Inglês | MEDLINE | ID: mdl-32400613

RESUMO

We present two prescriptions for broadband ($ {\sim} 77 - 252\;{\rm GHz} $), millimeter-wave antireflection coatings for cryogenic, sintered polycrystalline aluminum oxide optics: one for large-format (700 mm diameter) planar and plano-convex elements, the other for densely packed arrays of quasi-optical elements-in our case, 5 mm diameter half-spheres (called "lenslets"). The coatings comprise three layers of commercially available, polytetrafluoroethylene-based, dielectric sheet material. The lenslet coating is molded to fit the 150 mm diameter arrays directly, while the large-diameter lenses are coated using a tiled approach. We review the fabrication processes for both prescriptions, then discuss laboratory measurements of their transmittance and reflectance. In addition, we present the inferred refractive indices and loss tangents for the coating materials and the aluminum oxide substrate. We find that at 150 GHz and 300 K the large-format coating sample achieves $ (97 \pm 2)\% $ transmittance, and the lenslet coating sample achieves $ (94 \pm 3)\% $ transmittance.

3.
Phys Rev Lett ; 121(22): 221301, 2018 Nov 30.
Artigo em Inglês | MEDLINE | ID: mdl-30547645

RESUMO

We present results from an analysis of all data taken by the bicep2/Keck CMB polarization experiments up to and including the 2015 observing season. This includes the first Keck Array observations at 220 GHz and additional observations at 95 and 150 GHz. The Q and U maps reach depths of 5.2, 2.9, and 26 µK_{CMB} arcmin at 95, 150, and 220 GHz, respectively, over an effective area of ≈400 square degrees. The 220 GHz maps achieve a signal to noise on polarized dust emission approximately equal to that of Planck at 353 GHz. We take auto and cross spectra between these maps and publicly available WMAP and Planck maps at frequencies from 23 to 353 GHz. We evaluate the joint likelihood of the spectra versus a multicomponent model of lensed-ΛCDM+r+dust+synchrotron+noise. The foreground model has seven parameters, and we impose priors on some of these using external information from Planck and WMAP derived from larger regions of sky. The model is shown to be an adequate description of the data at the current noise levels. The likelihood analysis yields the constraint r_{0.05}<0.07 at 95% confidence, which tightens to r_{0.05}<0.06 in conjunction with Planck temperature measurements and other data. The lensing signal is detected at 8.8σ significance. Running a maximum likelihood search on simulations we obtain unbiased results and find that σ(r)=0.020. These are the strongest constraints to date on primordial gravitational waves.

4.
J Dent ; 131: 104466, 2023 04.
Artigo em Inglês | MEDLINE | ID: mdl-36804580

RESUMO

PURPOSE: The present study aims to assess the accuracy of sleeveless guided endodontics for root canal treatment of severe pulp canal obliteration (PCO) in 3D printed jaws. Additionally, the treatment of a complex lateral incisor is presented to illustrate the use of sleeveless guides in a clinical situation. METHODS: Two cone-beam computed tomography (CBCT) volumes of an upper and lower jaw were selected to design 3D printed models with PCO. Virtual planning of the access cavities was performed from right to left second premolar. Then, the models were mounted into a phantom head to simulate an actual patient. Two operators with different levels of experience in endodontics performed guided access cavities. The handpiece was guided by guiding rails placed against each other on the sides of the tooth. A post-operative CBCT scan was taken for analysis. RESULTS: Eighty-eight guided access cavities (44 per operator) were drilled on eight 3D printed models. The mean length of the access cavities was 15.3 mm, with a mean coronal and apical deviation of 0.5 mm and 0.7 mm respectively. The mean angular deviation was 1.5°. No statistically significant difference was found between operators for the three measured parameters. CONCLUSIONS: This study demonstrates, within its limitations, that sleveless guides represent an accurate method for guided endodontic treatment. No statistically significant difference between operators was found when using the guide. CLINICAL SIGNIFICANCE: This method offers a valuable alternative to conventional endodontic guides with similar accuracy results.


Assuntos
Cárie Dentária , Doenças da Polpa Dentária , Endodontia , Humanos , Incisivo/diagnóstico por imagem , Endodontia/métodos , Tratamento do Canal Radicular , Cavidade Pulpar/diagnóstico por imagem , Cavidade Pulpar/cirurgia , Tomografia Computadorizada de Feixe Cônico
5.
J Dent ; 135: 104566, 2023 08.
Artigo em Inglês | MEDLINE | ID: mdl-37263407

RESUMO

OBJECTIVES: To (1) validate the use of a post-operative intraoral scan (IOS) versus Cone Beam Computed Tomography (CBCT), gold standard, on its ability to measure the accuracy of guided endodontics, and (2) present clinical data on the accuracy of guided endodontics. METHODS: Four models, including 10 extracted teeth each, were created. Forty guided access cavities were planned on dentin to simulate pulp canal obliteration (PCO). Two operators performed guided access cavities. A post-operative CBCT and IOS were acquired. The coronal, apical, and angular deviations were measured with CBCT and IOS. Clinical accuracy was measured using an IOS acquired immediately after drilling the access cavity with the aid of a guide. Data analysis was performed using multiway Anova and corrected for simultaneous hypothesis testing according to Tukey. P ≤ 0.05 was considered statistically significant. Descriptive statistics on the clinical accuracy of guided endodontics were performed. RESULTS: Thirty-eight cavities were assessed with a mean length of 13.8 mm. No statistical difference between operators and methods was found for all parameters (P > 0.05). Thirty-three patients were treated with guided endodontics and measured using an IOS. Results show an average coronal, apical, and angular deviation of 0.2 mm, 0.45 mm, and 1.91° respectively. The average length of the access cavities was 12.5 mm. CONCLUSIONS: An IOS can be used to measure the accuracy of guided endodontics. Clinical data showed high accuracy of guided endodontics with a mean apical deviation smaller than 0.5 mm and a mean angular deviation of less than 2°. CLINICAL SIGNIFICANCE: The use of an IOS does not involve additional radiation exposure. A safety margin of at least 1 mm around the planned trajectory should be respected when planning the case to minimize the possibility of root perforation.


Assuntos
Cárie Dentária , Doenças da Polpa Dentária , Endodontia , Humanos , Cavidade Pulpar/diagnóstico por imagem , Tomografia Computadorizada de Feixe Cônico
6.
Rev Med Brux ; 15(6): 371-5, 1994.
Artigo em Francês | MEDLINE | ID: mdl-7824830

RESUMO

In paediatrics, ambulatory care under hospital control is ensured both by the out-patient department and by the emergency unit. If socio-economic level and parental availability are taken into account, the hospital remains the most accessible health-care structure in large towns. The common illnesses, in most cases infectious and respiratory, should not encumber the emergency unit, but should instead be taken in charge by a structure where an extended-timetable dispensary and an out-patient clinic by appointment work in parallel. In the most favourable cases, a home care unit completes this out-patient structure. Its main characteristics are as follows: it is exclusively paediatric, and it aims at shortening or avoiding hospitalization. It improves the quality of treatment, provides the family with medico-social support and follow-up that is particularly useful in less favoured settings, and can also offer preliminary training in heavy or chronic cases. Notwithstanding its obvious advantages, budgetary cuts have led to the suppression of home care at Hôpital Saint-Pierre in 1983.


Assuntos
Assistência Ambulatorial/organização & administração , Serviços de Saúde da Criança/organização & administração , Bélgica , Criança , Maus-Tratos Infantis/prevenção & controle , Pré-Escolar , Serviço Hospitalar de Emergência/estatística & dados numéricos , Hepatite Viral Humana/terapia , Serviços de Assistência Domiciliar/organização & administração , Hospitalização , Humanos , Lactente , Recém-Nascido , Tempo de Internação , Tuberculose/tratamento farmacológico
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA