J Appl Clin Med Phys ; 23(5): e13592, 2022 May.
Artigo em Inglês | MEDLINE | ID: mdl-35290701

RESUMO

PURPOSE: Total body irradiation (TBI) in extended source surface distance (SSD) is a common treatment technique before hematopoietic stem cell transplant. The lungs are organs at risk, which often are treated with a lower dose than the whole body. METHODS: This can be achieved by the application of blocks. Three-dimensional (3D) printers are a modern tool to be used in the production process of these blocks. RESULTS: We demonstrate the applicability of a specific printer and printing material, describe the process, and evaluate the accuracy of the product. CONCLUSION: The blocks and apertures were found to be applicable in clinical routine.


Assuntos
Impressão Tridimensional , Irradiação Corporal Total , Humanos , Imagens de Fantasmas , Irradiação Corporal Total/métodos
2.
BMC Cancer ; 20(1): 88, 2020 Feb 03.
Artigo em Inglês | MEDLINE | ID: mdl-32013920

RESUMO

BACKGROUND: This planning study compares different radiotherapy techniques for patients with pituitary adenoma, including flatness filter free mode (FFF), concerning plan quality and secondary malignancies for potentially young patients. The flatness filter has been described as main source of photon scatter. MATERIAL AND METHODS: Eleven patients with pituitary adenoma were included. An Elekta Synergy™ linac was used in the treatment planning system Oncentra® and for the measurements. 3D plans, IMRT, and VMAT plans and non-coplanar varieties were considered. The plan quality was evaluated regarding homogeneity, conformity, delivery time and dose to the organs at risk. The secondary malignancy risk was calculated from dose volume data and from measured dose to the periphery using different models for carcinoma and sarcoma risk. RESULTS: The homogeneity and conformity were nearly unchanged with and without flattening filter, neither was the delivery time found substantively different. VMAT plans were more homogenous, conformal and faster in delivery than IMRT plans. The secondary cancer risk was reduced with FFF both in the treated region and in the periphery. VMAT plans resulted in a higher secondary brain cancer risk than IMRT plans, but the risk for secondary peripheral cancer was reduced. Secondary sarcoma risk plays a minor role. No advantage was found for non-coplanar techniques. The FFF delivery times were not shortened due to additional monitor units needed and technical limitations. The risk for secondary brain cancer seems to depend on the irradiated volume. Secondary sarcoma risk is much smaller than carcinoma risk in accordance to the results of the atomic bomb survivors. The reduction of the peripheral dose and resulting secondary malignancy risk for FFF is statistically significant. However, it is negligible in comparison to the risk in the treated region. CONCLUSION: Treatments with FFF can reduce secondary malignancy risk while retaining similar quality as with flattening filter and should be preferred. VMAT plans show the best plan quality combined with lowest peripheral secondary malignancy risk, but highest level of second brain cancer risk. Taking this into account VMAT FFF seems the most advantageous technique for the treatment of pituitary adenomas with the given equipment.


Assuntos
Adenoma/radioterapia , Segunda Neoplasia Primária/epidemiologia , Neoplasias Hipofisárias/radioterapia , Radioterapia/métodos , Fatores Etários , Feminino , Humanos , Masculino , Radioterapia/efeitos adversos , Radioterapia/instrumentação , Dosagem Radioterapêutica , Planejamento da Radioterapia Assistida por Computador , Fatores de Risco
3.
J Appl Clin Med Phys ; 21(12): 197-205, 2020 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-33147377

RESUMO

Men treated for localized prostate cancer by radiotherapy have often a remaining life span of 10 yr or more. Therefore, the risk for secondary malignancies should be taken into account. Plans for ten patients were evaluated which had been performed on an Oncentra® treatment planning system for a treatment with an Elekta Synergy™ linac with Agility™ head. The investigated techniques involved IMRT and VMTA with and without flattening filter. Different dose response models were applied for secondary carcinoma and sarcoma risk in the treated region and also in the periphery. As organs at risk we regarded for carcinoma risk urinary bladder, rectum, colon, esophagus, thyroid, and for sarcoma risk bone and soft tissue. The excess absolute risk (EAR) was found very similar in the treated region for both techniques (IMRT and VMAT) and also for both with and without flattening filter. The secondary sarcoma risk resulted about one magnitude smaller than the secondary carcinoma risk. The EAR to the peripheral organs was statistically significant reduced by application of the flattening filter free mode concerning the flattening filter as main source of scattered dose. Application of flattening filter free mode can thus support to reduce second malignancy risk for patients with localized prostate cancer.


Assuntos
Segunda Neoplasia Primária , Neoplasias da Próstata , Radioterapia de Intensidade Modulada , Humanos , Masculino , Segunda Neoplasia Primária/etiologia , Neoplasias da Próstata/radioterapia , Dosagem Radioterapêutica , Planejamento da Radioterapia Assistida por Computador , Radioterapia de Intensidade Modulada/efeitos adversos
4.
J Appl Clin Med Phys ; 19(5): 632-639, 2018 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-30125453

RESUMO

Pediatric patients suffering from ependymoma are usually treated with cranial or craniospinal three-dimensional (3D) conformal radiotherapy (3DCRT). Intensity-modulated techniques spare dose to the surrounding tissue, but the risk for second malignancies may be increased due to the increase in low-dose volume. The aim of this study is to investigate if the flattening filter free (FFF) mode allows reducing the risk for second malignancies compared to the mode with flattening filter (FF) for intensity-modulated techniques and to 3DCRT. A reduction of the risk would be advantageous for treating pediatric ependymoma. 3DCRT was compared to intensity-modulated radiation therapy (IMRT) and volumetric-modulated arc therapy (VMAT) with and without flattening filter. Dose-volume histograms (DVHs) were compared to evaluate the plan quality and used to calculate the excess absolute risk (EAR) to develop second cancer in the brain. Dose verification was performed with a two-dimensional (2D) ionization chamber array and the out-of-field dose was measured with an ionization chamber to determine the EAR in peripheral organs. Delivery times were measured. Both VMAT and IMRT achieved similar plan quality in terms of dose sparing in the OAR and higher PTV coverage as compared to 3DCRT. Peripheral dose in low-dose region, which is proportional to the EAR in organs located in this region, for example, gonads, bladder, or bowel, could be significantly reduced using FFF. The lowest peripheral EAR and lowest delivery times were hereby achieved with VMATFFF . The EAR calculated based on DVH in the brain could not be reduced using FFF mode. VMATFFF improved the target coverage and homogeneity and kept the dose in the OAR similar compared to 3DCRT. In addition, delivery times were significantly reduced using VMATFFF . Therefore, for radiotherapy of ependymoma patients, VMATFFF may be considered advantageous for the combination of Elekta Synergy linac and Oncentra External Beam planning system used in this study.


Assuntos
Ependimoma/radioterapia , Adolescente , Criança , Pré-Escolar , Humanos , Lactente , Neoplasias Induzidas por Radiação , Segunda Neoplasia Primária , Aceleradores de Partículas , Dosagem Radioterapêutica , Planejamento da Radioterapia Assistida por Computador , Radioterapia de Intensidade Modulada , Estudos Retrospectivos
5.
J Appl Clin Med Phys ; 18(5): 307-314, 2017 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-28857432

RESUMO

This study on patients with localized prostate cancer was set up to investigate valuable differences using flattened beam (FB) and flattening filter free (FFF) mode in the application of intensity-modulated radiotherapy (IMRT) and volumetric-modulated arc therapy (VMAT). For ten patients, four different plans were calculated with Oncentra planning system of Elekta, using Synergy machines: IMRT and VMAT, with and without flattening filter. Homogeneity and conformity indexes, dose to the organs at risk, and measurements of peripheral dose and dosimetric plan verification including record of the delivery times were analyzed and statistically evaluated. The indexes for homogeneity and conformity (CTV and PTV) are either advantageous or not significantly different for FFF compared to FB with one minor exception. Regarding the doses to the organs at risk and the measured peripheral dose, equivalent or lower doses were delivered for FFF than with FB. Furthermore, the delivery times were significantly shorter for FFF. VMAT compared to IMRT reveals benefits or at least equivalent values. VMAT-FFF combines the most advantageous plan quality parameters with the shortest delivery times and reduced peripheral dose and is therefore recommended for the given equipment and cancer localization.


Assuntos
Neoplasias da Próstata/radioterapia , Planejamento da Radioterapia Assistida por Computador , Radioterapia de Intensidade Modulada/métodos , Idoso , Humanos , Masculino , Órgãos em Risco , Aceleradores de Partículas , Imagens de Fantasmas , Neoplasias da Próstata/patologia , Dosagem Radioterapêutica
6.
Strahlenther Onkol ; 192(6): 403-13, 2016 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-26968180

RESUMO

PURPOSE: Metallic dental implants cause severe streaking artifacts in computed tomography (CT) data, which affect the accuracy of dose calculations in radiation therapy. The aim of this study was to investigate the benefit of the metal artifact reduction algorithm iterative metal artifact reduction (iMAR) in terms of correct representation of Hounsfield units (HU) and dose calculation accuracy. MATERIALS AND METHODS: Heterogeneous phantoms consisting of different types of tissue equivalent material surrounding metallic dental implants were designed. Artifact-containing CT data of the phantoms were corrected using iMAR. Corrected and uncorrected CT data were compared to synthetic CT data to evaluate accuracy of HU reproduction. Intensity-modulated radiation therapy (IMRT) and volumetric modulated arc therapy (VMAT) plans were calculated in Oncentra v4.3 on corrected and uncorrected CT data and compared to Gafchromic™ EBT3 films to assess accuracy of dose calculation. RESULTS: The use of iMAR increased the accuracy of HU reproduction. The average deviation of HU decreased from 1006 HU to 408 HU in areas including metal and from 283 HU to 33 HU in tissue areas excluding metal. Dose calculation accuracy could be significantly improved for all phantoms and plans: The mean passing rate for gamma evaluation with 3 % dose tolerance and 3 mm distance to agreement increased from 90.6 % to 96.2 % if artifacts were corrected by iMAR. CONCLUSION: The application of iMAR allows metal artifacts to be removed to a great extent which leads to a significant increase in dose calculation accuracy.


Assuntos
Artefatos , Implantes Dentários , Intensificação de Imagem Radiográfica/métodos , Radiometria/métodos , Planejamento da Radioterapia Assistida por Computador/métodos , Tomografia Computadorizada por Raios X/métodos , Humanos , Metais , Imagens de Fantasmas , Dosagem Radioterapêutica , Reprodutibilidade dos Testes , Sensibilidade e Especificidade , Tomografia Computadorizada por Raios X/instrumentação
7.
Strahlenther Onkol ; 192(10): 687-95, 2016 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-27534409

RESUMO

BACKGROUND: The aim of this study was to investigate if the flattening filter free mode (FFF) of a linear accelerator reduces the excess absolute risk (EAR) for second cancer as compared to the flat beam mode (FF) in simultaneous integrated boost (SIB) radiation therapy of right-sided breast cancer. PATIENTS AND METHODS: Six plans were generated treating the whole breast to 50.4 Gy and a SIB volume to 63 Gy on CT data of 10 patients: intensity-modulated radiation therapy (IMRT), volumetric modulated arc therapy (VMAT), and a tangential arc VMAT (tVMAT), each with flattening filter and without. The EAR was calculated for the contralateral breast and the lungs from dose-volume histograms (DVH) based on the linear-exponential, the plateau, and the full mechanistic dose-response model. Peripheral low-dose measurements were performed to compare the EAR in more distant regions as the thyroids and the uterus. RESULTS: FFF reduces the EAR significantly in the contralateral and peripheral organs for tVMAT and in the peripheral organs for VMAT. No reduction was found for IMRT. The lowest EAR for the contralateral breast and lung was achieved with tVMAT FFF, reducing the EAR by 25 % and 29 % as compared to tVMAT FF, and by 44 % to 58 % as compared to VMAT and IMRT in both irradiation modes. tVMAT FFF showed also the lowest peripheral dose corresponding to the lowest EAR in the thyroids and the uterus. CONCLUSION: The use of FFF mode allows reducing the EAR significantly when tVMAT is used as the treatment technique. When second cancer risk is a major concern, tVMAT FFF is considered the preferred treatment option in SIB irradiation of right-sided breast cancer.


Assuntos
Neoplasias Induzidas por Radiação/etiologia , Neoplasias Induzidas por Radiação/prevenção & controle , Planejamento da Radioterapia Assistida por Computador/métodos , Radioterapia de Intensidade Modulada/efeitos adversos , Radioterapia de Intensidade Modulada/métodos , Neoplasias Unilaterais da Mama/radioterapia , Adulto , Idoso , Terapia Combinada , Feminino , Humanos , Pessoa de Meia-Idade , Hipofracionamento da Dose de Radiação , Fatores de Risco , Resultado do Tratamento , Neoplasias Unilaterais da Mama/complicações
8.
Strahlenther Onkol ; 191(3): 234-41, 2015 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-25359507

RESUMO

PURPOSE: Metallic dental implants cause severe streaking artefacts in computed tomography (CT) data, which inhibit the correct representation of shape and density of the metal and the surrounding tissue. The aim of this study was to investigate the impact of dental implants on the accuracy of dose calculations in radiation therapy planning and the benefit of metal artefact reduction (MAR). A second aim was to determine the treatment technique which is less sensitive to the presence of metallic implants in terms of dose calculation accuracy. MATERIALS AND METHODS: Phantoms consisting of homogeneous water equivalent material surrounding dental implants were designed. Artefact-containing CT data were corrected using the correct density information. Intensity-modulated radiation therapy (IMRT) and volumetric modulated arc therapy (VMAT) plans were calculated on corrected and uncorrected CT data and compared to 2-dimensional dose measurements using GafChromic™ EBT2 films. RESULTS: For all plans the accuracy of dose calculations is significantly higher if performed on corrected CT data (p = 0.015). The agreement of calculated and measured dose distributions is significantly higher for VMAT than for IMRT plans for calculations on uncorrected CT data (p = 0.011) as well as on corrected CT data (p = 0.029). CONCLUSION: For IMRT and VMAT the application of metal artefact reduction significantly increases the agreement of dose calculations with film measurements. VMAT was found to provide the highest accuracy on corrected as well as on uncorrected CT data. VMAT is therefore preferable over IMRT for patients with metallic implants, if plan quality is comparable for the two techniques.


Assuntos
Artefatos , Implantação Dentária Endóssea , Metais , Dosagem Radioterapêutica , Tomografia Computadorizada por Raios X/métodos , Algoritmos , Humanos , Imagens de Fantasmas , Planejamento da Radioterapia Assistida por Computador
9.
Strahlenther Onkol ; 185(4): 222-30, 2009 Apr.
Artigo em Alemão | MEDLINE | ID: mdl-19370424

RESUMO

BACKGROUND: Postoperative radiotherapy after breast cancer surgery effectively reduces local relapses. A survival benefit after breast conservation, however, has only been proven recently which was in part due to excessive cardiac mortality of patients who had been treated with radiotherapy in the past. MATERIAL AND METHODS: The literature on postoperative radiotherapy for breast cancer was reviewed with regard to cardiac toxicity as the basis for hypothesis generation. RESULTS: From numerous publications on cardiac toxicity of breast cancer radiotherapy, the following pattern emerges: in series where a high radiation dose was applied to a significant percentage of the heart (postmastectomy and postlumpectomy series) cardiac toxicity/mortality was increased versus a nonexposed cohort or for left over right disease. If, however, a relevant exposure of cardiac muscle could be more or less excluded based on the technique used (mainly more recent postlumpectomy radiotherapy), no cardiac toxicity was observed. Series for which individual dose exposure varied or could not be clarified also came to varying conclusions. Also due to retrospectively unclear dose distributions, an exact quantification of tolerance doses/effects of different geographic dose distribution patterns could not be performed to date. A particularly difficult question to answer is the threshold volume for clinically relevant cardiotoxicity with tangential radiotherapy at prescription doses. As a consequence, this precludes an estimate in which situations multifield intensity-modulated radiotherapy (IMRT) with its characteristic dose distribution pattern of a larger volume exposed to intermediate doses and higher mean/median heart doses (as shown in Figure 1) might be preferable. CONCLUSION: This review updates the database on cardiac toxicity of breast cancer radiotherapy with special emphasis regarding the issues related to the clinical use of IMRT. Multifield IMRT may reduce the cardiac risk for a small subset of patients at excessive risk with conventional tangential radiotherapy due to unfavorable thoracic geometry, for whom partial-breast radiotherapy is not an option. Due to further concern about the effects of intermediate doses to larger heart volumes, potentially increased contralateral cancer risk and the long latency of clinically apparent toxicity, the introduction of breast IMRT should be closely followed. Accompanying functional studies may have the potential to detect cardiac toxicity at an earlier time.


Assuntos
Neoplasias da Mama/mortalidade , Neoplasias da Mama/terapia , Cardiopatias/epidemiologia , Cardiopatias/prevenção & controle , Mastectomia/mortalidade , Radioterapia Conformacional/mortalidade , Comorbidade , Feminino , Humanos , Incidência , Mastectomia/estatística & dados numéricos , Medição de Risco/métodos , Fatores de Risco , Resultado do Tratamento
10.
J Appl Clin Med Phys ; 10(4): 4-15, 2009 Sep 02.
Artigo em Inglês | MEDLINE | ID: mdl-19918235

RESUMO

The purpose of the study was to investigate the potential of direct machine parameter optimization (DMPO) to achieve parotid sparing without compromising target coverage in IMRT of oropharyngeal cancer as compared to fluence modulation with subsequent leaf sequencing (IM) and forward planned 2-step arc therapy (IMAT). IMRT plans were generated for 10 oropharyngeal cancer patients using DMPO and IM. The resulting dose volume histograms (DVH) were evaluated with regard to compliance with the dose volume objectives (DVO) and plan quality. DMPO met the DVO for the targets better than IM but violated the DVO to the parotids in some cases. DMPO provided better target coverage and dose homogeneity than IM and comparable to IMAT. Dose to the parotids (23Gy) was significantly lower than for IMAT (48Gy), but somewhat higher than for IM (20Gy). Parotid sparing with IM was, however, only achieved at the cost of target coverage and homogeneity. DMPO allows achieving parotid sparing in the treatment of oropharyngeal cancer without compromising target coverage and dose homogeneity in the target as compared to 2-step IMAT. Better overall plan quality can be delivered with less monitor units than with IM.


Assuntos
Neoplasias Orofaríngeas/radioterapia , Planejamento da Radioterapia Assistida por Computador , Radioterapia de Intensidade Modulada , Humanos , Glândula Parótida/efeitos da radiação , Prognóstico , Dosagem Radioterapêutica , Medula Espinal/efeitos da radiação
11.
Z Med Phys ; 19(4): 288-93, 2009.
Artigo em Alemão | MEDLINE | ID: mdl-19995529

RESUMO

The check of dosimetry of the intraoperative radiotherapy system Intrabeam is predefined by the manufacture (Zeiss). The purpose of the study was to develop and implement a method to verify the internal dosimetry of Intrabeam (Zeiss). Additionally the long-term stability of Intrabeam was checked for dose and isotropy. For dose to water measurements an Unidos was combined with a soft jet chamber (TM 23342) which was calibrated in water absorbed dose and as a phantom the type 2962 (PTW Freiburg) was used. RW1 plates were inserted as build up material. The applicators were placed in a bag filled with water to consider the side-scattering. At the surface of the applicator there was a mean difference of 3 percent between the dose to water measurement and the internal dosimetry. The constancy of the dose rate showed a mean deviation of 0.3% at the reference point. The analysis of the dose distribution perpendicular to the applicator axis z (reference z-axis) resulted in a mean deviation of -2.7% (x-direction) and -7,1% (-x-direction) for the x-axis and, respectively -4.1% (y-direction) and -5.3% (-y-direction) for the y-axis. The proposed method is suitable to verify the absolute dose of Intrabeam. The dose values measured by this method were congruent to the dosimetry of the manufacture (Zeiss). From our point of view it is sufficient to verify the absolute dosimetry only at time of commissioning of the system or in the case of changing the applicator. For the daily routine the check of constancy specified by the manufacture is adequate, because the dose rate is checked on a daily basis. Additionally the test of constancy showed a high long-term stability in terms of dose rate and symmetry.


Assuntos
Doses de Radiação , Radiometria/métodos , Radioterapia/métodos , Simulação por Computador , Análise de Falha de Equipamento/métodos , Humanos , Período Intraoperatório , Imagens de Fantasmas , Monitoramento de Radiação/métodos
12.
Z Med Phys ; 19(1): 58-66, 2009.
Artigo em Alemão | MEDLINE | ID: mdl-19459586

RESUMO

INTRODUCTION: Recent data suggest that a radiosurgery boost treatment for up to three brain metastases in addition to whole brain radiotherapy (WBRT) is beneficial. Sequential treatment of multiple metastatic lesions is time-consuming and optimal normal tissue sparing is not trivial for larger metastases when separate plans are created and are only superimposed afterwards. Sequential Tomotherapy (see image I) with noncoplanar arcs and Multi-field IMRT may streamline the process and enable easy simultaneous treatment. We compared plans for 2-3 intracerebral targets calculated with Intensity Modulated Radiotherapy (IMRT) based on treatment with MLC or sequential Tomotherapy using the Peacock-System (see image II). Treatment time was not to exceed 90 min on a linac with standard dose rate. MIMiC plans without treatment-time restrictions were created as a benchmark. MATERIALS AND METHODS: Calculations are based on a Siemens KD2 linac with a dose rate of 200 MU/min. Step-and-Shoot IMRT is performed with a standard MLC (2 x 29 leaves, 1 cm), serial Tomotherapy with the Multivane-Collimator MIMiC (NOMOS Inc. USA) (see image II). Treatment plans are created with Corvus 5.0. To create plans with good conformity we chose a noncoplanar beam- and arc geometry for each approach (IMRT 4-, MIMiC 5-couch angles). The benchmark MIMiC plans with maximally steep dose gradients had 9 couch angles. For plan comparison reasons, 10 Gy were prescribed to 90% of the PTV. Steepness of dose gradients, homogeneity and conformity were assessed by the following parameters: Volume encompassed by certain isodoses outside the target as well as homogeneity and conformity as indicated by Homogeneity- and Conformity-Index. RESULTS: Plans without treatment-time restrictions had slightest dose to organ at risk (OAR), normal tissue and least Conformity-index. MIMiC- and MLC-IMRT based plans can be treated within the intended period of 90 min, all plans met the required dose (see Table 2). MLC based plans resulted in higher dose to organs at risk (OAR) (see table 1) and dose to tissue outside the targets (see table 3), as indicated by a higher CI (see image III). The HI was similar for all calculated plans (see image IV). DISCUSSION: When treatment plans resulting in a similar treatment time were compared, serial Tomotherapy showed minor advantages over MLC based IMRT with regard to conformity, OAR sparing, and steepness of dose gradients. Both methods are inferior to serial Tomotherapy with ideal plan quality disregarding treatment efficiency. Treating multiple metastases in less than 1 h would therefore be possible on a LINAC with high dose rate and bidirectional rotation with minor compromises on gradient steepness.


Assuntos
Neoplasias Encefálicas/radioterapia , Planejamento da Radioterapia Assistida por Computador/métodos , Radioterapia de Intensidade Modulada/métodos , Neoplasias Encefálicas/secundário , Neoplasias Encefálicas/cirurgia , Humanos , Metástase Neoplásica/radioterapia , Planejamento de Assistência ao Paciente , Radiocirurgia/métodos , Dosagem Radioterapêutica , Radioterapia Conformacional/métodos , Estudos Retrospectivos
13.
Strahlenther Onkol ; 184(2): 86-92, 2008 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-18259700

RESUMO

PURPOSE: Evaluation of a simplified intensity-modulated irradiation (IMRT), a three-field (MFT), and a conventional two-tangential-field technique regarding dose homogeneity, target coverage, feasibility and, for the first time, dosimetric reliability in patients with large breasts treated postoperatively for breast cancer on a low-energy linac. MATERIAL AND METHODS: CT datasets of ten patients with relatively large breast volumes treated for breast cancer were selected. For each patient, four treatment plans were created: low-energy conventional (C-LE), high-energy conventional (C-HE), three-field (MFT), and a two-field aperture-based IMRT technique. Apertures for the IMRT and MFT were created with the aid of a three-dimensional dose display. Dosimetric accuracy of each technique was evaluated in an anthropomorphic thorax/breast phantom. RESULTS: The mean of planning target volumes receiving < 95% or > 105% of the prescribed total dose was reduced from 16.0% to 13.9% to 10.4% to 8.9% in the C-LE, C-HE, MFT, and IMRT plans, respectively. Phantom dose measurements agreed well with the calculated dose within the breast tissue. CONCLUSION: Aperture-based IMRT using two tangential incident beam directions, as well as a three-field technique with inverse optimization, provide a better alternative to the standard wedged tangential beams for patients with large breasts treated on low-energy linacs while maintaining the efficiency of the treatment-planning and delivery process.


Assuntos
Algoritmos , Neoplasias da Mama/fisiopatologia , Neoplasias da Mama/radioterapia , Modelos Biológicos , Radiometria/métodos , Planejamento da Radioterapia Assistida por Computador/métodos , Radioterapia Conformacional/métodos , Mama/fisiopatologia , Simulação por Computador , Feminino , Humanos , Tamanho do Órgão , Dosagem Radioterapêutica , Eficiência Biológica Relativa , Reprodutibilidade dos Testes , Espalhamento de Radiação , Sensibilidade e Especificidade
14.
Int J Radiat Oncol Biol Phys ; 67(1): 288-95, 2007 Jan 01.
Artigo em Inglês | MEDLINE | ID: mdl-17189077

RESUMO

PURPOSE: In external beam radiotherapy (EBRT) and especially in intensity-modulated radiotherapy (IMRT), the accuracy of the dose distribution in the patient is of utmost importance. It was investigated whether image guided in vivo dosimetry in the rectum is a reliable method for online dose verification. METHODS AND MATERIALS: Twenty-one dose measurements were performed with an ionization chamber in the rectum of 7 patients undergoing IMRT for prostate cancer. The position of the probe was determined with cone beam computed tomography (CBCT). The point of measurement was determined relative to the isocenter and relative to an anatomic reference point. The dose deviations relative to the corresponding doses in the treatment plan were calculated. With an offline CT soft-tissue match, patient positioning after ultrasound was verified. RESULTS: The mean magnitude +/- standard deviation (SD) of patient positioning errors was 3.0 +/- 2.5 mm, 5.1 +/- 4.9 mm, and 4.3 +/- 2.4 mm in the left-right, anteroposterior and craniocaudal direction. The dose deviations in points at corresponding positions relative to the isocenter were -1.4 +/- 4.9% (mean +/- SD). The mean dose deviation at corresponding anatomic positions was 6.5 +/- 21.6%. In the rare event of insufficient patient positioning, dose deviations could be >30% because of the close proximity of the probe and the posterior dose gradient. CONCLUSIONS: Image-guided dosimetry in the rectum during IMRT of the prostate is a feasible and reliable direct method for dose verification when probe position is effectively controlled.


Assuntos
Neoplasias da Próstata/radioterapia , Radiometria/métodos , Dosagem Radioterapêutica , Radioterapia de Intensidade Modulada/normas , Reto , Estudos de Viabilidade , Humanos , Masculino , Neoplasias da Próstata/diagnóstico por imagem , Controle de Qualidade , Radiometria/normas , Radioterapia de Intensidade Modulada/métodos , Reto/diagnóstico por imagem , Tomografia Computadorizada por Raios X , Ultrassonografia
15.
Radiat Oncol ; 12(1): 114, 2017 Jul 05.
Artigo em Inglês | MEDLINE | ID: mdl-28679448

RESUMO

BACKGROUND: The aim of this study was to investigate if the flattening filter free (FFF) irradiation mode of a linear accelerator (linac) is advantageous as compared to the flat beam (FF) irradiation mode in intensity modulated radiation therapy (IMRT) and volumetric modulated arc therapy (VMAT) for carcinoma of the hypopharynx / larynx. METHODS: Four treatment plans were created for each of 10 patients for an Elekta Synergy linac with Agility collimating device, a dual arc VMAT and a nine field step and shoot IMRT each with and without flattening filter. Plan quality was compared considering target coverage and dose to the organs at risk. All plans were verified by a 2D-ionization-chamber-array and delivery times were compared. Peripheral point doses were determined as a measure of second cancer risk. The Wilcoxon test was used for statistical analysis with a significance level of 0.05. RESULTS: Plan quality was similar for all four treatment plans without statistically significant differences of clinical relevance. The clinical goals were met in all plans for the PTV-SIB (V95% > 95%), the spinal cord (D1ccm < 45 Gy) and the brain stem (D1ccm < 48 Gy). For the parotids, the goal of D50% < 30 Gy was met in 70% and 60% of the plans for the left and right parotid respectively, and the V95% of the SIB reached an average of 94%. Delivery times were similar for FF and FFF and significantly decreased by around 70% for VMAT as compared to IMRT. Peripheral doses were significantly reduced by 18% in FFF mode as compared to FF and by 26% for VMAT as compared to IMRT. Lowest peripheral doses were found for VMAT FFF, followed by VMAT FF. CONCLUSIONS: The FFF mode of a linear accelerator is advantageous for the treatment of hypopharynx/larynx carcinoma only with respect to reduction of second cancer induction in peripheral organs for the combination of Elekta Synergy linacs and Oncentra® External Beam v4.5 treatment planning system. This might be of interest in a therapy with curative intent.


Assuntos
Neoplasias Hipofaríngeas/radioterapia , Neoplasias Laríngeas/radioterapia , Órgãos em Risco/efeitos da radiação , Aceleradores de Partículas/instrumentação , Planejamento da Radioterapia Assistida por Computador/métodos , Radioterapia de Intensidade Modulada/métodos , Humanos , Prognóstico , Dosagem Radioterapêutica
16.
Stud Health Technol Inform ; 119: 404-6, 2006.
Artigo em Inglês | MEDLINE | ID: mdl-16404087

RESUMO

Based on a stochastic mutual information type matching and RPROP as stochastic optimizer, an interactive image-based registration of a CT volume onto two 2D images provided by a megavoltage system is presented. The matching process is based on semi-automatic pre-segmentation, an approximate 2D-2D matching with precomputed virtual projections (DRRs) followed by an accurate 3D-2D matching step. Our sample-based approach requires only a fraction of computed DRRs for 3D-2D. A simultaneous computation of the DRR rays and their perturbations in 6 dimensions speeds up the rendering process by a factor of 6.8. The complete registration process takes 5.6 +/- 2.3 seconds on a 3 GHz Pentium IV PC, being the fastest non-parallel approach for this sort of application the authors are aware of.


Assuntos
Apresentação de Dados , Radioterapia Assistida por Computador , Tomografia Computadorizada por Raios X , Alemanha
17.
Radiat Oncol ; 11(1): 111, 2016 Aug 31.
Artigo em Inglês | MEDLINE | ID: mdl-27577561

RESUMO

BACKGROUND: The aim of the study was to compare the two irradiation modes with (FF) and without flattening filter (FFF) for three different treatment techniques for simultaneous integrated boost radiation therapy of patients with right sided breast cancer. METHODS: An Elekta Synergy linac with Agility collimating device is used to simulate the treatment of 10 patients. Six plans were generated in Monaco 5.0 for each patient treating the whole breast and a simultaneous integrated boost (SIB) volume: intensity modulated radiation therapy (IMRT), volumetric modulated arc therapy (VMAT) and a tangential arc VMAT (tVMAT), each with and without flattening filter. Plan quality was assessed considering target coverage, sparing of the contralateral breast, the lungs, the heart and the normal tissue. All plans were verified by a 2D-ionisation-chamber-array and delivery times were measured and compared. The Wilcoxon test was used for statistical analysis with a significance level of 0.05. RESULTS: Significantly best target coverage and homogeneity was achieved using VMAT FFF with V95% = (98.7 ± 0.8) % and HI = (8.2 ± 0.9) % for the SIB and V95% = (98.3 ± 0.7) % for the PTV, whereas tVMAT showed significantly lowest doses to the contralateral organs at risk with a Dmean of (0.7 ± 0.1) Gy for the contralateral lung, (1.0 ± 0.2) Gy for the contralateral breast and (1.4 ± 0.2) Gy for the heart. All plans passed the gamma evaluation with a mean passing rate of (99.2 ± 0.8) %. Delivery times were significantly reduced for VMAT and tVMAT but increased for IMRT, when FFF was used. Lowest delivery times were observed for tVMAT FFF with (1:20 ± 0:07) min. CONCLUSION: Balancing target coverage, OAR sparing and delivery time, VMAT FFF and tVMAT FFF are considered the preferable of the investigated treatment options in simultaneous integrated boost irradiation of right sided breast cancer for the combination of an Elekta Synergy linac with Agility and the treatment planning system Monaco 5.0.


Assuntos
Neoplasias da Mama/radioterapia , Radioterapia de Intensidade Modulada/métodos , Neoplasias Unilaterais da Mama/radioterapia , Feminino , Humanos , Radiometria/métodos , Dosagem Radioterapêutica , Planejamento da Radioterapia Assistida por Computador/métodos , Estudos Retrospectivos
18.
Radiat Oncol ; 11: 33, 2016 Mar 01.
Artigo em Inglês | MEDLINE | ID: mdl-26932561

RESUMO

BACKGROUND: The aim of this study was to investigate the potential of the flattening filter free (FFF) mode of a linear accelerator for intensity modulated radiation therapy (IMRT) and volumetric modulated arc therapy (VMAT) for patients with in-field recurrence of vertebral metastases. METHODS: An Elekta Synergy Linac with Agility™ head is used to simulate the treatment of ten patients with locally recurrent spinal column metastases. Four plans were generated for each patient treating the vertebrae sparing the spinal cord: Dual arc VMAT and nine field step and shoot IMRT each with and without flattening filter. Plan quality was assessed considering target coverage and sparing of the spinal cord and normal tissue. All plans were verified by a 2D-ionisation-chamber-array, peripheral doses were measured and compared to calculations. Delivery times were measured and compared. The Wilcoxon test was used for statistical analysis with a significance level of 0.05. RESULTS: Target coverage, homogeneity index and conformity index were comparable for both flat and flattening filter free beams. The volume of the spinal cord receiving the allowed maximum dose to keep the risk of radiation myelopathy at 0 % was at the same time significantly reduced to below the clinically relevant 1 ccm using FFF mode. In addition the mean dose deposited in the surrounding healthy tissue was significantly reduced in the FFF mode. All four techniques showed equally good gamma scores for plan verification. FFF plans required considerably more MU per fraction dose. Regardless of the large number of MU, out-of-field point dose was significantly lower for FFF plans, with an average reduction of 33 % and mean delivery time was significantly reduced by 22 % using FFF beams. When compared to IMRT FF, VMAT FFF offered even a reduction of 71 % in delivery time and 45 % in peripheral dose. CONCLUSIONS: FFF plans showed a significant improvement in sparing of normal tissue and the spinal cord, keeping target coverage and homogeneity comparable. In addition, delivery times were significantly reduced for FFF treatments, minimizing intrafractional motion as well as strain for the patient. Shortest delivery times were achieved using VMAT FFF. For radiotherapy of spinal column metastases VMAT FFF may therefore be considered the preferable treatment option for the combination of Elekta Synergy Linacs and Oncentra® External Beam v4.5 treatment planning system.


Assuntos
Recidiva Local de Neoplasia/radioterapia , Radioterapia de Intensidade Modulada/métodos , Reirradiação/métodos , Neoplasias da Coluna Vertebral/radioterapia , Simulação por Computador , Humanos , Metástase Neoplásica , Órgãos em Risco , Aceleradores de Partículas , Radiometria/métodos , Dosagem Radioterapêutica , Planejamento da Radioterapia Assistida por Computador/métodos , Neoplasias da Coluna Vertebral/secundário , Tomografia Computadorizada por Raios X
19.
Radiat Oncol ; 11: 81, 2016 Jun 10.
Artigo em Inglês | MEDLINE | ID: mdl-27287010

RESUMO

INTRODUCTION: A sweeping beam technique for total body irradiation in standard treatment rooms and for standard linear accelerators (linacs) is introduced, which does not require any accessory attached to the linac. Lung shielding is facilitated to reduce the risk of pulmonary toxicity. Additionally, the applicability of a commercial radiotherapy planning system (RTPS) is examined. MATERIAL AND METHODS: The patient is positioned on a low couch on the floor, the longitudinal axis of the body in the rotational plane of the linac. Eight arc fields and five additional fixed beams are applied to the patient in supine and prone position respectively. The dose distributions were measured in a solid water phantom and in an Alderson phantom. Diode detectors were calibrated for in-vivo dosimetry. The RTPS Oncentra was employed for calculations of the dose distribution. RESULTS: For the cranial 120 cm the longitudinal dose profile in a slab phantom measured with ionization chamber varies between 94 and 107 % of the prescription dose. These values were confirmed by film measurements and RTPS calculations. The transmittance of the lung shields has been determined as a function of the thickness of the absorber material. Measurements in an Alderson phantom and in-vivo dosimetry of the first patients match the calculated dose. DISCUSSION AND CONCLUSION: A treatment technique with clinically good dose distributions has been introduced, which can be applied with each standard linac and in standard treatment rooms. Dose calculations were performed with a commercial RTPS and should enable individual dose optimization.


Assuntos
Pulmão/efeitos da radiação , Planejamento de Assistência ao Paciente , Imagens de Fantasmas , Lesões por Radiação/prevenção & controle , Radiometria/instrumentação , Planejamento da Radioterapia Assistida por Computador/métodos , Irradiação Corporal Total/métodos , Calibragem , Humanos , Tratamentos com Preservação do Órgão , Aceleradores de Partículas
20.
Int J Radiat Oncol Biol Phys ; 59(4): 1236-44, 2004 Jul 15.
Artigo em Inglês | MEDLINE | ID: mdl-15234061

RESUMO

PURPOSE: Data from the randomized Intergroup Trial 116 suggest effectiveness of adjuvant radiochemotherapy in patients with advanced gastric cancer. Late toxicity, however, especially with respect to the kidneys, may pose significant longtime problems. Intensity-modulated radiotherapy (IMRT) may reduce toxicity to organs at risk. To evaluate the relative merits of different IMRT approaches, we performed a plan comparison between a step-and-shoot class solution and an AP-PA setup, a conventional box technique and the Peacock tomotherapy approach. METHODS AND MATERIALS: Computed tomographies and structure data from 15 patients who had been treated postoperatively for advanced (T3/T4/N+) gastric cancer at our department formed the basis of our plan comparison study. For each patient data set, 5 plans or plan combinations (conventional 3D plan, AP-PA plan, step-and-shoot IMRT, tomotherapy with 1-cm or 2-cm collimation) were chosen, and evaluation was performed for a total dose of 45 Gy delivered as the median dose to the target volume for each plan or plan combination. RESULTS: Median kidney dose generated from the IMRT plans is reduced individually by >50% for the kidney with the highest exposure (usually the left kidney) from 20 to 30 Gy with conventional 3D planning down to values between 8 and 10 Gy for IMRT. On average, median dose to the right kidney is the same for the conventional box technique and IMRT (between 8 and 10 Gy) but lower for the AP-PA technique. In 3 patients, kidney dose might have been ablative for both kidneys with both the AP-PA technique and the box technique, whereas it was acceptable with IMRT. Median dose to the liver was subcritical with all modalities but lowest with AP-PA fields. Differences between step-and-shoot IMRT and tomotherapy plans are small when compared to the differences between IMRT plans and conventional conformal 3D plans. For some patients, however, their body and target diameters obviate treatment with tomotherapy. Treatment time for the step-and-shoot approach and for tomotherapy with 2-cm collimation can be kept <20 min. CONCLUSIONS: For postoperative radiotherapy of advanced gastric cancer, step-and-shoot IMRT as well as tomotherapy can deliver efficient doses to target volumes while delivering dose to the kidneys in a fashion that is different from a conventional technique and is clearly advantageous in a small number of patients. An advantage for the majority of patients is likely with the normal tissue complication probability data presented in this series, but, given the uncertainty of the reaction of the kidney to inhomogeneous dose distributions, cannot be considered unequivocal at the moment. Different technical limitations apply to the different IMRT techniques. The choice of approach is therefore determined by departmental circumstances.


Assuntos
Rim/efeitos da radiação , Lesões por Radiação/prevenção & controle , Radioterapia Conformacional/métodos , Neoplasias Gástricas/radioterapia , Humanos , Fígado/efeitos da radiação , Radioterapia Adjuvante , Neoplasias Gástricas/diagnóstico por imagem , Neoplasias Gástricas/cirurgia , Tomografia Computadorizada por Raios X
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA