Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 71
Filtrar
Mais filtros

Base de dados
Tipo de documento
Intervalo de ano de publicação
1.
Eur Radiol ; 32(1): 152-162, 2022 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-34255159

RESUMO

OBJECTIVE: The aim of the current study was, first, to assess the coronary artery calcium (CAC) scoring potential of spectral photon-counting CT (SPCCT) in comparison with computed tomography (CT) for routine clinical protocols. Second, improved CAC detection and quantification at reduced slice thickness were assessed. METHODS: Raw data was acquired and reconstructed with several combinations of reduced slice thickness and increasing strengths of iterative reconstruction (IR) for both CT systems with routine clinical CAC protocols for CT. Two CAC-containing cylindrical inserts, consisting of CAC of different densities and sizes, were placed in an anthropomorphic phantom. A specific CAC was detectable when 3 or more connected voxels exceeded the CAC scoring threshold of 130 Hounsfield units (HU). For all reconstructions, total CAC detectability was compared between both CT systems. Significant differences in CAC quantification (Agatston and volume scores) were assessed with Mann-Whitney U tests. Furthermore, volume scores were compared with the known CAC physical. RESULTS: CAC scores for routine clinical protocols were comparable between SPCCT and CT. SPCCT showed 34% and 4% higher detectability of CAC for the small and large phantom, respectively. At reduced slice thickness, CAC detection increased by 142% and 169% for CT and SPCCT, respectively. In comparison with CT, volume scores from SPCCT were more comparable with the physical volume of the CAC. CONCLUSION: CAC scores using routine clinical protocols are comparable between conventional CT and SPCCT. The increased spatial resolution of SPCCT allows for increased detectability and more accurate CAC volume estimation. KEY POINTS: • Coronary artery calcium scores using routine clinical protocols are comparable between conventional CT and spectral photon-counting CT. • In comparison with conventional CT, increased coronary artery calcium detectability was shown for spectral photon-counting CT due to increased spatial resolution. • Volumes scores were more accurately determined with spectral photon-counting CT.


Assuntos
Cálcio , Doença da Artéria Coronariana , Doença da Artéria Coronariana/diagnóstico por imagem , Vasos Coronários/diagnóstico por imagem , Humanos , Imagens de Fantasmas , Tomografia Computadorizada por Raios X
2.
Eur Radiol ; 32(5): 3447-3457, 2022 May.
Artigo em Inglês | MEDLINE | ID: mdl-34997284

RESUMO

OBJECTIVE: The aim of the current study was to systematically assess coronary artery calcium (CAC) detection and quantification for spectral photon-counting CT (SPCCT) in comparison to conventional CT and, in addition, to evaluate the possibility of radiation dose reduction. METHODS: Routine clinical CAC CT protocols were used for data acquisition and reconstruction of two CAC containing cylindrical inserts which were positioned within an anthropomorphic thorax phantom. In addition, data was acquired at 50% lower radiation dose by reducing tube current, and slice thickness was decreased. Calcifications were considered detectable when three adjacent voxels exceeded the CAC scoring threshold of 130 Hounsfield units (HU). Quantification of CAC (as volume and mass score) was assessed by comparison with known physical quantities. RESULTS: In comparison with CT, SPCCT detected 33% and 7% more calcifications for the small and large phantoms, respectively. At reduced radiation dose and reduced slice thickness, small phantom CAC detection increased by 108% and 150% for CT and SPCCT, respectively. For the large phantom size, noise levels interfered with CAC detection. Although comparable between CT and SPCCT, routine protocols CAC quantification showed large deviations (up to 134%) from physical CAC volume. At reduced radiation dose and slice thickness, physical volume overestimations decreased to 96% and 72% for CT and SPCCT, respectively. In comparison with volume scores, mass score deviations from physical quantities were smaller. CONCLUSION: CAC detection on SPCCT is superior to CT, and was even preserved at a reduced radiation dose. Furthermore, SPCCT allows for improved physical volume estimation. KEY POINTS: • In comparison with conventional CT, increased coronary artery calcium detection (up to 156%) for spectral photon-counting CT was found, even at 50% radiation dose reduction. • Spectral photon-counting CT can more accurately measure physical volumes than conventional CT, especially at reduced slice thickness and for high-density coronary artery calcium. • For both conventional and spectral photon-counting CT, reduced slice thickness reconstructions result in more accurate physical mass approximation.


Assuntos
Calcinose , Doença da Artéria Coronariana , Calcinose/diagnóstico por imagem , Cálcio , Doença da Artéria Coronariana/diagnóstico por imagem , Vasos Coronários/diagnóstico por imagem , Humanos , Imagens de Fantasmas , Doses de Radiação , Tomografia Computadorizada por Raios X/métodos
3.
Eur Radiol ; 31(7): 5324-5334, 2021 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-33449188

RESUMO

OBJECTIVES: To compare the spectral performance of dual-energy CT (DECT) platforms using task-based image quality assessment based on phantom data. MATERIALS AND METHODS: Two CT phantoms were scanned on four DECT platforms: fast kV-switching CT (KVSCT), split filter CT (SFCT), dual-source CT (DSCT), and dual-layer CT (DLCT). Acquisitions on each phantom were performed using classical parameters of abdomen-pelvic examination and a CTDIvol at 10 mGy. Noise power spectrum (NPS) and task-based transfer function (TTF) were evaluated from 40 to 140 keV of virtual monoenergetic images. A detectability index (d') was computed to model the detection task of two contrast-enhanced lesions as function of keV. RESULTS: The noise magnitude decreased from 40 to 70 keV for all DECT platforms, and the highest noise magnitude values were found for KVSCT and SFCT and the lowest for DSCT and DLCT. The average NPS spatial frequency shifted towards lower frequencies as the energy level increased for all DECT platforms, smoothing the image texture. TTF values decreased with the increase of keV deteriorating the spatial resolution. For both simulated lesions, higher detectability (d' value) was obtained at 40 keV for DLCT, DSCT, and SFCT but at 70 keV for KVSCT. The detectability of both simulated lesions was highest for DLCT and DSCT. CONCLUSION: Highest detectability was found for DLCT for the lowest energy levels. The task-based image quality assessment used for the first time for DECT acquisitions showed the benefit of using low keV for the detection of contrast-enhanced lesions. KEY POINTS: • Detectability of both simulated contrast-enhanced lesions was higher for dual-layer CT for the lowest energy levels. • The image noise increased and the image texture changed for the lowest energy levels. • The detectability of both simulated contrast-enhanced lesions was highest at 40 keV for all dual-energy CT platforms except for fast kV-switching platform.


Assuntos
Imagem Radiográfica a Partir de Emissão de Duplo Fóton , Tomografia Computadorizada por Raios X , Abdome/diagnóstico por imagem , Humanos , Imagens de Fantasmas , Razão Sinal-Ruído
5.
J Neuroradiol ; 38(3): 148-55, 2011 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-20728218

RESUMO

PURPOSE: To evaluate the agreement and diagnostic accuracy of Contrast enhanced magnetic resonance angiography (CE-MRA), Doppler ultrasound (DUS) and Digital subtraction angiography (DSA) in the assessment of carotid stenosis. METHODS: DUS, CE-MRA and DSA were performed in 56 patients included in the Carotide-angiographie par résonance magnétique-échographie-doppler-angioscanner (CARMEDAS) multicenter study with a carotid stenosis ≥ 50%. Three readers evaluated stenoses on CE-MRA and DSA (NASCET criteria). Velocities criteria were used for stenosis estimation on DUS. RESULTS: CE-MRA had a sensitivity and specificity of 96-98% and 66-83% respectively for carotid stenoses ≥ 50% and a sensitivity and specificity of 94% and 76-84% respectively for carotid stenoses ≥ 70%. The interobserver agreement of CE-MRA was excellent, except for moderate stenoses (50-69%). DUS had a sensitivity and specificity of 88 and 75% respectively for carotid stenoses ≥ 50% and a sensitivity and specificity of 83 and 86% respectively for carotid stenoses ≥ 70%. Combined concordant CE-MRA and DUS had a sensitivity and specificity of 100 and 85-90% respectively for carotid stenoses ≥ 50% and a sensitivity and specificity of 96-100% and 80-87% respectively for carotid stenoses ≥ 70%. The positive predictive value of the association CE-MRA and DUS for carotid stenoses ≥ 70% is calculated between 77 and 82% while the negative predictive value is calculated between 97 and 100%. CE-MRA and DUS have concordant findings in 63-72%, and the overestimations cases were recorded only for carotid stenosis ≤ 69%. CONCLUSION: Combined DUS-CE-MRA is excellent for evaluation of severe stenosis but remains debatable in moderate stenosis (50-69%) due to the risk of overestimations.


Assuntos
Estenose das Carótidas/diagnóstico , Imageamento Tridimensional , Angiografia por Ressonância Magnética , Ultrassonografia Doppler , Idoso , Idoso de 80 Anos ou mais , Estenose das Carótidas/diagnóstico por imagem , Estenose das Carótidas/patologia , Meios de Contraste , Feminino , Humanos , Interpretação de Imagem Assistida por Computador , Masculino , Pessoa de Meia-Idade , Valor Preditivo dos Testes , Sensibilidade e Especificidade
6.
J Radiol ; 91(2): 185-94, 2010 Feb.
Artigo em Francês | MEDLINE | ID: mdl-20389265

RESUMO

A third of cerebrovascular accidents are a complication from carotid artery plaque. In addition to the degree of stenosis, plaque composition and morphology are key elements in determining the probability of complication from the atherosclerotic plaque. High resolution MRI can characterize plaque composition and morphology and therefore help identify unstable plaque. The purpose of this review is to summarize recent concepts on unstable plaque and underlying inflammation. The signal characteristics of the different components of plaque on high resolution MRI then be reviewed. Finally, current morphological and functional criteria for unstable plaque will be discussed.


Assuntos
Doenças das Artérias Carótidas/diagnóstico , Imageamento por Ressonância Magnética , Humanos
7.
Diagn Interv Imaging ; 101(5): 289-297, 2020 May.
Artigo em Inglês | MEDLINE | ID: mdl-31932228

RESUMO

PURPOSE: To determine the lowest suitable dose level for the detection of pulmonary arteriovenous malformation (PAVM) using a task-based image quality assessment. MATERIAL AND METHODS: A phantom was scanned using the standard chest protocol (STD) and 4 other ultra-low dose protocols (ULD) using various kVp. Raw data were reconstructed using level 5 of the hybrid iterative reconstruction algorithm (iDose4) for the STD protocol, and level 6 of iDose4 and levels 1 to 3 of model-based iterative reconstruction (IMR) for the ULD protocols. Both quantitative criteria and qualitative analysis were used to compare protocols. Noise-power-spectrum and Task-based transfer function were computed using imQuest software. The detectability-index (d') was computed for the detection of PAVM. A subjective analysis was performed by 2 chest radiologists to validate the image-quality obtained on the anthropomorphic phantom for all protocols. RESULTS: Similar d' values were found for ULD-140 using iDose4 6 compared to STD protocol. Greater d' values were found for all ULD protocols using IMR compared to STD. Subjective image quality was rated as acceptable to excellent for ULD-140 and ULD-120 for all reconstruction types, for ULD-100 and ULD-80 using IMR2, and for ULD-100 using IMR1. Image smoothing was poor for IMR3 for ULD-100 and ULD-80. Finally, the ULD-80 protocol reconstructed with IMR2 was chosen for the detection of PAVM. With this protocol, the dose (CTDIvol of 0.3mGy) was reduced by 91% compared with the STD protocol. CONCLUSION: A dose level as low as 0.3mGy reconstructed with IMR2 provides an image quality suitable for the detection of PAVM.


Assuntos
Malformações Arteriovenosas , Interpretação de Imagem Radiográfica Assistida por Computador , Algoritmos , Malformações Arteriovenosas/diagnóstico por imagem , Humanos , Imagens de Fantasmas , Doses de Radiação , Tomografia Computadorizada por Raios X
8.
Diagn Interv Imaging ; 101(5): 299-310, 2020 May.
Artigo em Inglês | MEDLINE | ID: mdl-32173289

RESUMO

PURPOSE: To compare the quantitative and qualitative lung perfusion data acquired with dual energy CT (DECT) to that acquired with a large field-of-view cadmium-zinc-telluride camera single-photon emission CT coupled to a CT system (SPECT-CT). MATERIALS AND METHODS: A total of 53 patients who underwent both dual-layer DECT angiography and perfusion SPECT-CT for pulmonary hypertension or pre-operative lobar resection surgery were retrospectively included. There were 30 men and 23 women with a mean age of 65.4±17.5 (SD)years (range: 18-88years). Relative lobar perfusion was calculated by dividing the amount (of radiotracer or iodinated contrast agent) per lobe by the total amount in both lungs. Linear regression, Bland-Altman analysis, and Pearson's correlation coefficient were also calculated. Kappa test was used to test agreements in morphology and severity of perfusion defects assessed on SPECT-CT and on DECT iodine maps with a one-month interval. Wilcoxon rank sum test was used to compare the sharpness of perfusion defects and radiation dose among modalities. RESULTS: Strong correlations for relative lobar perfusion using linear regression analysis and Pearson's correlation coefficient (r=0.93) were found. Bland-Altman analysis revealed a -0.10 bias, with limits of agreement between [-6.01; 5.81]. With respect to SPECT- CT as standard of reference, the sensitivity, specificity, PPV, NPV, accuracy for lobar perfusion defects were 89.4% (95% CI: 82.6-93.4%), 96.5% (95% CI: 92.1-98.5%), 95.6% (95% CI: 90.9-97.8%), 91.4% (95% CI: 85.6-94.9%) and 93.0% (95% CI: 87.6-96.1%) respectively. High level of agreement was found for morphology and severity of perfusion defects between modalities (Kappa=0.84 and 0.86 respectively) and on DECT images among readers (Kappa=0.94 and 0.89 respectively). A significantly sharper delineation of perfusion defects was found on DECT images (P<0.0001) using a significantly lower equivalent dose of 4.1±2.3 (SD) mSv (range: 1.9-11.85mSv) compared to an equivalent dose of 5.3±1.1 (SD) mSv (range: 2.8-7.3mSv) for SPECT-CT, corresponding to a 21.2% dose reduction (P=0.0004). CONCLUSION: DECT imaging shows strong quantitative correlations and qualitative agreements with SPECT-CT for the evaluation of lung perfusion.


Assuntos
Pulmão , Tomografia Computadorizada por Raios X , Adolescente , Idoso , Feminino , Humanos , Pulmão/diagnóstico por imagem , Masculino , Pessoa de Meia-Idade , Perfusão , Estudos Retrospectivos , Sensibilidade e Especificidade , Tomografia Computadorizada de Emissão de Fóton Único , Adulto Jovem
9.
J Radiol ; 90(9 Pt 2): 1172-5, 2009 Sep.
Artigo em Francês | MEDLINE | ID: mdl-19752827

RESUMO

The recent and future advancements that are known in the field of cardiac imaging imply an optimal training of the operators. This training concerns medical specialists whether originating from radiology or cardiology. The training of the medical specialists in cardiac imaging entitles 3 main essential steps: The basic training taking place within each specialty, allowing the fellow to get acquainted with the clinical and technical basics. The specialized training, delivered principally in post-residency. This training must include an upgrading of each specialty in the domain that does not concern it (a technical base for the cardiologist, a physio-pathological and clinical base for the radiologist). It must include a specific theoretical training covering all aspects of cardiac imaging as well as practical training in a certified training centre. The continuous medical training and maintenance of skills that allow a sustained activity in the field and the obligation to regularly participate in the actions of specific validated training. The different aspects of these rules are exposed in this chapter.


Assuntos
Cardiopatias/diagnóstico , Radiologia/educação , Diagnóstico por Imagem , Guias como Assunto , Humanos
10.
Diagn Interv Imaging ; 100(3): 177-183, 2019 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-30497958

RESUMO

INTRODUCTION: The purpose of this study was to develop a convolutional neural network (CNN) to determine the extent of over-scanning in the Z-direction associated with lung computed tomography (CT) examinations. MATERIALS AND METHODS: The CT examinations of 250 patients were used to train the machine learning software and 100 were used to validate the results. Each lung CT examination was divided into cervical, lung, and abdominal areas by the CNN and 2 independent radiologists, and the length of each area was measured. Every part above or below the lung marks was labeled as over-scanning. The accuracy of the CNN was calculated after the training phase and agreement between CNN and radiologists was assessed using kappa statistics during the validation phase. After validation the software was used to estimate the length of each of the three areas and the total over-scanning in further 1000 patients. RESULTS: An accuracy of 0.99 was found for the testing dataset and a very good agreement (kappa=0.98) between the CNN and the radiologists' evaluation was found for the validation dataset. Over-scanning was 22.8% with the CNN and 22.2% with the radiologists. The degree of over-scanning was 22.6% in 1000 lung CT examinations. CONCLUSION: Our study shows a substantial over estimation of the length of the area to be scanned during lung CT and thus an unnecessary patient's over-exposure to ionizing radiation. This over-scanning can be assessed easily, reliably and quickly using CNN.


Assuntos
Pulmão/diagnóstico por imagem , Aprendizado de Máquina , Redes Neurais de Computação , Tomografia Computadorizada por Raios X/métodos , Inteligência Artificial , Humanos , Sensibilidade e Especificidade
11.
J Cardiovasc Surg (Torino) ; 48(1): 1-6, 2007 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-17308515

RESUMO

AIM: The endoluminal stent-grafting represents an alternative to surgery in the treatment of lesions of the descending thoracic aorta. The purpose of the present study was to evaluate the mid-term results of the Talent stent-graft in the different indications of aortic disease and the use of magnetic resonance angiography (MRA) in the diagnosis of complications. METHODS: Over a 3-year period, 23 patients with a high surgical risk and presenting a localized lesion of the descending thoracic aorta had an implantation of a Talent stent-graft. Indications were degenerative aneurysm (n=13), false aneurysm (n=7) and penetrating atherosclerotic ulcer (n=3). The feasibility of the endovascular treatment and sizing of the aorta and stent-grafts were determined pre-operatively by MRA and intraoperative angiography. Immediate and mid-term technical and clinical success were assessed by clinical and MRA follow-up. RESULTS: Endovascular treatment was completed successfully in all patients with no conversion to open repair. There was no intraoperative mortality. The mean operative time was 38+/-7 min. Primary success rate was 100%. We didn't have perioperative mortality. The mean follow-up period was 15+/-5 months. The survival rate was 97% (n=22). Regression of the aneurysmal size was observed in 70% (n=16). MRA diagnosed 3 over 4 postoperative endoleaks that were not diagnosed with the CT-scan, and did not interfere with the nitinol structure of the stent-graft. CONCLUSIONS: Endovascular treatment of the various localized diseases of the descending thoracic aorta is a promising, feasible, alternative technique to open surgery in well selected patients. MRA is well adapted to diagnose postoperative endoleaks.


Assuntos
Falso Aneurisma , Aneurisma da Aorta Torácica , Aterosclerose , Implante de Prótese Vascular/métodos , Angiografia por Ressonância Magnética , Stents , Úlcera , Idoso , Idoso de 80 Anos ou mais , Falso Aneurisma/diagnóstico , Falso Aneurisma/epidemiologia , Falso Aneurisma/cirurgia , Aorta Torácica/patologia , Aorta Torácica/cirurgia , Aneurisma da Aorta Torácica/diagnóstico , Aneurisma da Aorta Torácica/epidemiologia , Aneurisma da Aorta Torácica/cirurgia , Aterosclerose/complicações , Aterosclerose/diagnóstico , Aterosclerose/cirurgia , Diagnóstico Diferencial , Feminino , Seguimentos , Humanos , Incidência , Masculino , Pessoa de Meia-Idade , Estudos Prospectivos , Reprodutibilidade dos Testes , Sensibilidade e Especificidade , Taxa de Sobrevida/tendências , Fatores de Tempo , Resultado do Tratamento , Úlcera/diagnóstico , Úlcera/etiologia , Úlcera/cirurgia
12.
J Radiol ; 87(11 Pt 1): 1637-41, 2006 Nov.
Artigo em Francês | MEDLINE | ID: mdl-17095958

RESUMO

The recent developments in the multi-slice CT scanner require evaluation of the clinical indications of this new tool for imaging coronary arteries. Improvements in spatial and temporal resolution with this new generation of CT (16 slices and more) allow the acquisition of coronary arteries with a sufficient quality in the majority of cases. After a short review of the technical principles of the cardiac CT, this article considers the clinical indications of this new method in the general evaluation of coronary artery disease.


Assuntos
Angiografia Coronária , Doença das Coronárias/diagnóstico por imagem , Tomografia Computadorizada por Raios X , Algoritmos , Doença das Coronárias/fisiopatologia , Diástole , Frequência Cardíaca , Humanos , Valor Preditivo dos Testes , Prognóstico , Valores de Referência , Medição de Risco , Fatores de Risco , Sensibilidade e Especificidade , Tomografia Computadorizada por Raios X/métodos
13.
J Am Coll Cardiol ; 20(4): 942-51, 1992 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-1527306

RESUMO

OBJECTIVES: The purpose of this study was to examine the coronary artery response to percutaneous transluminal coronary angioplasty by using intravascular ultrasound. BACKGROUND: The immediate effects of coronary angioplasty on arterial wall geometry and surface appearance are understood poorly. Most of the available data are derived from small necropsy series, inferred from animal models or extrapolated from in vitro studies. High frequency intravascular ultrasound provides transmural images of coronary arteries in vivo. METHODS: We used intravascular ultrasound to study 29 patients before or after, or both, successful coronary angioplasty. RESULTS: The angiographic diameter narrowing was 72 +/- 13% before and improved to 19 +/- 11% after angioplasty. Calcium was visualized in 7 (24%) of the 29 angioplasty sites by fluoroscopy versus 15 (52%) of sites by intravascular ultrasound (p = 0.022). Arterial dissection after angioplasty was observed in 8 (27%) of cases by contrast angiography versus 24 (83%) by intravascular ultrasound (p less than 0.001). Intravascular ultrasound detected extensive dissection at the angioplasty site in 11 (73%) of the 15 calcified plaques and in only 3 (21%) of the 14 noncalcified plaques (p = 0.024). Arterial expansion (defined as the area within the external elastic membrane at the angioplasty site greater than that of the proximal reference segment) occurred in 29% of calcified plaques compared with 86% of noncalcified plaques (p = 0.007). CONCLUSIONS: Intravascular ultrasound is more sensitive than angiography for identifying arterial calcium and dissection at the site of angioplasty. At the site of angioplasty, arterial dissection occurred more frequently in calcified plaques whereas arterial expansion occurred more frequently in noncalcified plaques. Successful angioplasty causes a continuum of arterial responses that vary importantly with plaque composition.


Assuntos
Angioplastia Coronária com Balão , Doença da Artéria Coronariana/terapia , Vasos Coronários/diagnóstico por imagem , Calcinose/diagnóstico por imagem , Calcinose/terapia , Angiografia Coronária , Doença da Artéria Coronariana/diagnóstico por imagem , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Sensibilidade e Especificidade , Ultrassonografia/métodos
14.
J Am Coll Cardiol ; 20(5): 1149-55, 1992 Nov 01.
Artigo em Inglês | MEDLINE | ID: mdl-1401615

RESUMO

OBJECTIVES: The purpose of this study was to evaluate the frequency, amount and distribution of target lesion calcification in patients undergoing transcatheter therapy for symptomatic coronary artery disease. BACKGROUND: Coronary artery target lesion calcification may be an important determinant of response to transcatheter therapy: balloon angioplasty causes dissections in calcified lesions, directional atherectomy cuts calcium poorly, rotational atherectomy causes preferential ablation of calcium and laser irradiation effect may vary. Intravascular ultrasound imaging is a highly sensitive technique for detection of plaque calcification in vivo. METHODS: We performed intravascular ultrasound imaging before or after, or both, various transcatheter therapies in 110 patients. These 84 men and 26 women had a mean age of 60 years and a duration of angina of 22 +/- 34 months. Forty-nine patients had one-vessel, 29 had two-vessel, 25 had three-vessel and 7 had left main coronary disease. Vessels treated and imaged were the left main (n = 7), left anterior descending (n = 47), left circumflex (n = 18) and right (n = 38) coronary arteries. RESULTS: Eighty-four patients (76%) had target lesion calcification; 29 patients had one-quadrant, 25 had two-quadrant, 17 had three-quadrant and 13 had four-quadrant calcification. The calcification was superficial in 42 patients, deep in 13 and both superficial and deep in 31. The axial length of calcium could be measured in 29 patients; it was < or = 5 mm in 11 and > or = 6 mm in 18. Fluoroscopy detected calcification in 50 patients (48%, p < 0.001 vs. detection by ultrasound); this proportion increased to 74% in patients with calcification of two or more quadrants and to 86% in patients with calcification > or = 6 mm in length of two or more quadrants. Calcification was more common in patients who smoked and tended to be more common in patients with multivessel disease or previous coronary artery bypass graft surgery. CONCLUSIONS: We conclude that target lesion calcification occurs in 75% of patients with symptomatic coronary artery disease requiring angioplasty. Target lesion calcification is best detected, localized and quantified by intravascular ultrasound. These observations may be important in selecting devices for transcatheter therapy.


Assuntos
Calcinose/diagnóstico por imagem , Doença das Coronárias/diagnóstico por imagem , Vasos Coronários/diagnóstico por imagem , Adulto , Idoso , Análise de Variância , Calcinose/epidemiologia , Calcinose/terapia , Cateterismo Periférico , Distribuição de Qui-Quadrado , Doença Crônica , Angiografia Coronária , Doença das Coronárias/epidemiologia , Doença das Coronárias/terapia , Feminino , Fluoroscopia , Humanos , Masculino , Pessoa de Meia-Idade , Ultrassonografia/instrumentação , Ultrassonografia/métodos , Ultrassonografia/estatística & dados numéricos
15.
Diagn Interv Imaging ; 96(9): 885-90, 2015 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-25697831

RESUMO

Cardiac magnetic resonance (CMR) provides a high signal-to-noise ratio, high spatial and temporal resolutions, as well as a delayed-enhancement sequence and is therefore considered a reference technique in the field of cardiac imaging. However, currently available sequences are not adequate to assess some pathologic conditions, such as myocardial edema. T2 mapping sequences generate parametric images that are based on the transverse relaxation time (T2) for each voxel. In case of edema, the T2 relaxation time is longer. This review summarizes current knowledge on CMR T2 mapping for assessing myocardial edema.


Assuntos
Cardiomiopatias/diagnóstico , Edema/diagnóstico , Interpretação de Imagem Assistida por Computador/métodos , Imageamento por Ressonância Magnética/métodos , Miocárdio/patologia , Biópsia , Cardiomiopatias/patologia , Edema/patologia , Endocárdio/patologia , Humanos , Sensibilidade e Especificidade
16.
Diagn Interv Imaging ; 96(3): 265-72, 2015 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-25543870

RESUMO

OBJECTIVE: Despite the obligatory recording of doses administered to patients during CT scans, this data is not easily accessible. The objective of this study was to implement and validate a computerised automated dose-recording system for CT scans, for a single radiology department. MATERIAL AND METHODS: Every patient undergoing a CT scan in our department over a one-year period was included in the study. The CT scanner was upgraded after eight months (installation of iterative reconstruction and choice of an additional voltage of 100 kV). The system recorded, from DICOM image headers, the patient data and technical acquisition parameters. The statistical analysis compared the dose length products (DLP) before and after the upgrade, and compared them with the diagnostic reference levels (DRL). RESULTS: Four thousand seven hundred and ninety-five CT scans were included (2141 before the upgrade and 2654 after). For all of the acquisition protocols tested, there was a reduction in DLP after the upgrade. The mean reduction was 30%, with a range of 17% to 44% depending on the protocol. After the upgrade, all of the mean DLPs were under the DRL thresholds (P<0.0001). CONCLUSION: The proposed tool enabled systematic recording of the doses of radiation used in CT scans. It confirmed the significant reduction in the dose resulting from the implementation of iterative reconstruction, and enabled an exhaustive and rapid control of the respect of DRLs.


Assuntos
Processamento de Imagem Assistida por Computador , Sistemas Computadorizados de Registros Médicos , Doses de Radiação , Exposição à Radiação , Tomografia Computadorizada por Raios X/métodos , Adolescente , Adulto , Idoso , Idoso de 80 Anos ou mais , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Serviço Hospitalar de Radiologia , Adulto Jovem
17.
Radiat Prot Dosimetry ; 164(1-2): 116-9, 2015 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-25342609

RESUMO

The objective of this study was to propose diagnostic reference levels (DRLs) for coronary computed tomography angiography (CCTA), in the context of a large variability in patient radiation dose, and the lack of European recommendations. Volume Computed Tomography Dose Index (CTDIvol) and dose-length product (DLP) were collected from 460 CCTAs performed over a 3-month period at eight French hospitals. CCTAs (∼50 per centre) were performed using the routine protocols of the centres, and 64- to 320-detector CT scanners. ECG gating was prospective (n = 199) or retrospective (n = 261). The large gap in dose between these two modes required to propose specific DRLs: 26 and 44 mGy for CTDIvol, and 370 and 970 mGy cm for DLP, respectively. This study confirms the large variability in patient doses during CCTA and underlines the need for the optimisation of cardiac acquisition protocols. Availability of national DRLs should be mandatory in this setting.


Assuntos
Angiografia Coronária/estatística & dados numéricos , Angiografia Coronária/normas , Radiometria/estatística & dados numéricos , Radiometria/normas , Tomografia Computadorizada por Raios X/estatística & dados numéricos , Tomografia Computadorizada por Raios X/normas , Doses de Radiação , Valores de Referência , Inquéritos e Questionários
18.
Am J Cardiol ; 74(7): 647-50, 1994 Oct 01.
Artigo em Inglês | MEDLINE | ID: mdl-7942520

RESUMO

The contribution of tissue removal to lumen improvement after directional coronary atherectomy remains controversial. The purpose of this study was to validate the intravascular ultrasound measurement of plaque volume and use it to study the contribution of tissue removal to lumen improvement after directional coronary atherectomy. With use of intravascular ultrasound, 12 human coronary vessels were imaged in vitro. With use of computer-assisted planimetry, the external elastic membrane and lumen cross-sectional areas were manually traced and the plaque+media area was calculated at 1 mm axial intervals. Then, plaque+media volume was calculated by Simpson's rule. After imaging, ultrasound measurements of plaque+media volume were compared with histologic measurements. Similarly, volumetric intravascular ultrasound imaging was performed before and after directional atherectomy in 47 patients. In vitro, the mean plaque+media volume measured by intravascular ultrasound was 134.0 +/- 94.8 mm3 and compared well with that derived by histology (187.4 +/- 128.8 mm3, r = 0.96, p < 0.001). In vivo, the lumen volume increased from 27.2 +/- 12.3 to 58.7 +/- 30.3 mm3, and the mean plaque+media volume decreased from 122.0 +/- 74.0 to 97.5 +/- 63.5 mm3. The mean intravascular ultrasound atherectomy index was 76 +/- 23%. In 11 of the 47 patients (23.4%), tissue removal alone accounted for lumen improvement. Volumetric intravascular ultrasound image analysis indicates that the mechanism of directional coronary atherectomy primarily is tissue removal. As a result, the contribution of arterial remodeling (expansion and dissection) probably is less important.


Assuntos
Aterectomia Coronária , Doença da Artéria Coronariana/cirurgia , Vasos Coronários/diagnóstico por imagem , Idoso , Aterectomia Coronária/métodos , Doença da Artéria Coronariana/diagnóstico por imagem , Doença da Artéria Coronariana/patologia , Vasos Coronários/patologia , Humanos , Processamento de Imagem Assistida por Computador , Masculino , Pessoa de Meia-Idade , Ultrassonografia de Intervenção
19.
Invest Radiol ; 29(5): 547-52, 1994 May.
Artigo em Inglês | MEDLINE | ID: mdl-8077094

RESUMO

RATIONALE AND OBJECTIVES: The performance of a rheolytic catheter designed to provide rapid fragmentation and evacuation of debris was evaluated. Specifically, fragmentation and evacuation efficiency was investigated in vitro. METHODS: Fragmentation, aspiration, and recanalization of large thrombotic occlusions (8-cm length, 6-mm inner diameter) composed of clot (n = 11) or collagen gels (n = 20) of different stiffness were performed with different jet pressures at rates optimized by visual observation and were recorded on videotape for subsequent analysis. The size and number of the resulting particles in the evacuated fluid and those remaining in the artificial vessel were determined using filtration and laser light scattering techniques. The rate of fragmentation, mean particulate size, and efficiency of evacuation were evaluated as a function of operating parameters and "clot stiffness." RESULTS: Complete fragmentation of fresh thrombus occurred at 11,000 psi by direct action of the 6 radially disposed jets, which created a trapping vortex from which most of the particles (80%) were evacuated by suction. At lower pressure (5,500 psi), fragmentation efficiency was unchanged for fresh thrombus and softer 5% gels. Ninety-five percent of the thrombus was fragmented in very small particles with a mean diameter of 0.8 +/- 0.4 micron, while 5% of the mass of the fragmented thrombus was in particles > 40 microns. At 11,000 psi, the maximal rate of advancement associated with complete material fragmentation decreased with stiffness. For very stiff gels or heavily cross-linked old thrombus, complete fragmentation and removal of material was not achieved. CONCLUSION: The high-pressure rheolytic catheter rapidly fragmented and evacuated large thrombi much larger than the catheter diameter--features with potential for treating large thrombi, such as acute pulmonary emboli or deep vein thrombi. However, this rapid forceful disruption may damage vessel walls and invariably creates a broad range of particulate sizes, which makes evacuation of almost all of the particulate material imperative to minimize clinically relevant distal embolization.


Assuntos
Cateterismo/instrumentação , Trombectomia/instrumentação , Desenho de Equipamento , Humanos , Modelos Cardiovasculares , Modelos Estruturais , Tamanho da Partícula
20.
Invest Radiol ; 35(1): 41-9, 2000 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-10639035

RESUMO

RATIONALE AND OBJECTIVES: To evaluate the use of two new blood pool contrast agents (P760, P775) compared with a low-molecular-weight gadolinium chelate in MR angiography. METHODS: The r1 efficiency of P760 was evaluated in vitro at 1.5 T; 3D abdominal contrast-enhanced MR angiography with qualitative analysis was compared in four rabbits after injection of incremental doses of P760 and in one rabbit after Gd-DOTA. A dynamic MR study was performed using a 2D T1-weighted turbo-flash MR sequence after injection of P760, P775, and Gd-DOTA. Each compound was tested at equivalent doses in three rabbits to assess r1 efficiency. Quantitative analysis of signal intensity in the aorta, the inferior vena cava, the renal cortex, and the medulla was performed. RESULTS: In vitro, the r1 efficiency of P760 was 23.3 mmol(-1) x L x sec(-1) at 1.5 T. Injection of a dose of P760 10 times less than Gd-DOTA allowed similar vessel visualization. The signal intensity peak and first-pass contrast kinetics in the aorta and the inferior vena cava were similar with the three products. Compared with P760 and Gd-DOTA, P775 allowed a greater renal cortex signal intensity at the first pass and a faster decrease on delayed images. CONCLUSIONS: The superior r1 efficiency of P760 and P775 was confirmed in vitro and in vivo at 1.5 T compared with Gd-DOTA, and P775 proved to be a rapid-clearance blood pool agent.


Assuntos
Meios de Contraste/farmacocinética , Angiografia por Ressonância Magnética , Animais , Gadolínio , Compostos Heterocíclicos , Compostos Organometálicos/farmacocinética , Projetos Piloto , Coelhos
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA