Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 14 de 14
Filtrar
1.
Sensors (Basel) ; 17(2)2017 Jan 31.
Artigo em Inglês | MEDLINE | ID: mdl-28146122

RESUMO

A highly versatile Electrical Impedance Tomography (EIT) system, nicknamed the ScouseTom, has been developed. The system allows control over current amplitude, frequency, number of electrodes, injection protocol and data processing. Current is injected using a Keithley 6221 current source, and voltages are recorded with a 24-bit EEG system with minimum bandwidth of 3.2 kHz. Custom PCBs interface with a PC to control the measurement process, electrode addressing and triggering of external stimuli. The performance of the system was characterised using resistor phantoms to represent human scalp recordings, with an SNR of 77.5 dB, stable across a four hour recording and 20 Hz to 20 kHz. In studies of both haeomorrhage using scalp electrodes, and evoked activity using epicortical electrode mats in rats, it was possible to reconstruct images matching established literature at known areas of onset. Data collected using scalp electrode in humans matched known tissue impedance spectra and was stable over frequency. The experimental procedure is software controlled and is readily adaptable to new paradigms. Where possible, commercial or open-source components were used, to minimise the complexity in reproduction. The hardware designs and software for the system have been released under an open source licence, encouraging contributions and allowing for rapid replication.


Assuntos
Impedância Elétrica , Animais , Eletrodos , Humanos , Imagens de Fantasmas , Tomografia , Tomografia Computadorizada por Raios X
2.
Front Surg ; 10: 1222859, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-37780914

RESUMO

Background: Endoscopic endonasal surgery is an established minimally invasive technique for resecting pituitary adenomas. However, understanding orientation and identifying critical neurovascular structures in this anatomically dense region can be challenging. In clinical practice, commercial navigation systems use a tracked pointer for guidance. Augmented Reality (AR) is an emerging technology used for surgical guidance. It can be tracker based or vision based, but neither is widely used in pituitary surgery. Methods: This pre-clinical study aims to assess the accuracy of tracker-based navigation systems, including those that allow for AR. Two setups were used to conduct simulations: (1) the standard pointer setup, tracked by an infrared camera; and (2) the endoscope setup that allows for AR, using reflective markers on the end of the endoscope, tracked by infrared cameras. The error sources were estimated by calculating the Euclidean distance between a point's true location and the point's location after passing it through the noisy system. A phantom study was then conducted to verify the in-silico simulation results and show a working example of image-based navigation errors in current methodologies. Results: The errors of the tracked pointer and tracked endoscope simulations were 1.7 and 2.5 mm respectively. The phantom study showed errors of 2.14 and 3.21 mm for the tracked pointer and tracked endoscope setups respectively. Discussion: In pituitary surgery, precise neighboring structure identification is crucial for success. However, our simulations reveal that the errors of tracked approaches were too large to meet the fine error margins required for pituitary surgery. In order to achieve the required accuracy, we would need much more accurate tracking, better calibration and improved registration techniques.

3.
IEEE Trans Biomed Eng ; PP2023 Oct 19.
Artigo em Inglês | MEDLINE | ID: mdl-37856260

RESUMO

OBJECTIVE: Reconstructing freehand ultrasound in 3D without any external tracker has been a long-standing challenge in ultrasound-assisted procedures. We aim to define new ways of parameterising long-term dependencies, and evaluate the performance. METHODS: First, long-term dependency is encoded by transformation positions within a frame sequence. This is achieved by combining a sequence model with a multi-transformation prediction. Second, two dependency factors are proposed, anatomical image content and scanning protocol, for contributing towards accurate reconstruction. Each factor is quantified experimentally by reducing respective training variances. RESULTS: 1) The added long-term dependency up to 400 frames at 20 frames per second (fps) indeed improved reconstruction, with an up to 82.4% lowered accumulated error, compared with the baseline performance. The improvement was found to be dependent on sequence length, transformation interval and scanning protocol and, unexpectedly, not on the use of recurrent networks with long-short term modules; 2) Decreasing either anatomical or protocol variance in training led to poorer reconstruction accuracy. Interestingly, greater performance was gained from representative protocol patterns, than from representative anatomical features. CONCLUSION: The proposed algorithm uses hyperparameter tuning to effectively utilise long-term dependency. The proposed dependency factors are of practical significance in collecting diverse training data, regulating scanning protocols and developing efficient networks. SIGNIFICANCE: The proposed new methodology with publicly available volunteer data and code for parametersing the long-term dependency, experimentally shown to be valid sources of performance improvement, which could potentially lead to better model development and practical optimisation of the reconstruction application.

4.
Med Image Anal ; 90: 102943, 2023 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-37703675

RESUMO

Augmented Reality (AR) is considered to be a promising technology for the guidance of laparoscopic liver surgery. By overlaying pre-operative 3D information of the liver and internal blood vessels on the laparoscopic view, surgeons can better understand the location of critical structures. In an effort to enable AR, several authors have focused on the development of methods to obtain an accurate alignment between the laparoscopic video image and the pre-operative 3D data of the liver, without assessing the benefit that the resulting overlay can provide during surgery. In this paper, we present a study that aims to assess quantitatively and qualitatively the value of an AR overlay in laparoscopic surgery during a simulated surgical task on a phantom setup. We design a study where participants are asked to physically localise pre-operative tumours in a liver phantom using three image guidance conditions - a baseline condition without any image guidance, a condition where the 3D surfaces of the liver are aligned to the video and displayed on a black background, and a condition where video see-through AR is displayed on the laparoscopic video. Using data collected from a cohort of 24 participants which include 12 surgeons, we observe that compared to the baseline, AR decreases the median localisation error of surgeons on non-peripheral targets from 25.8 mm to 9.2 mm. Using subjective feedback, we also identify that AR introduces usability improvements in the surgical task and increases the perceived confidence of the users. Between the two tested displays, the majority of participants preferred to use the AR overlay instead of navigated view of the 3D surfaces on a separate screen. We conclude that AR has the potential to improve performance and decision making in laparoscopic surgery, and that improvements in overlay alignment accuracy and depth perception should be pursued in the future.


Assuntos
Realidade Aumentada , Laparoscopia , Cirurgia Assistida por Computador , Humanos , Imageamento Tridimensional/métodos , Laparoscopia/métodos , Fígado/diagnóstico por imagem , Fígado/cirurgia , Cirurgia Assistida por Computador/métodos
5.
Med Phys ; 50(5): 2695-2704, 2023 May.
Artigo em Inglês | MEDLINE | ID: mdl-36779419

RESUMO

BACKGROUND: Accurate camera and hand-eye calibration are essential to ensure high-quality results in image-guided surgery applications. The process must also be able to be undertaken by a nonexpert user in a surgical setting. PURPOSE: This work seeks to identify a suitable method for tracked stereo laparoscope calibration within theater. METHODS: A custom calibration rig, to enable rapid calibration in a surgical setting, was designed. The rig was compared against freehand calibration. Stereo reprojection, stereo reconstruction, tracked stereo reprojection, and tracked stereo reconstruction error metrics were used to evaluate calibration quality. RESULTS: Use of the calibration rig reduced mean errors: reprojection (1.47 mm [SD 0.13] vs. 3.14 mm [SD 2.11], p-value 1e-8), reconstruction (1.37 px [SD 0.10] vs. 10.10 px [SD 4.54], p-value 6e-7), and tracked reconstruction (1.38 mm [SD 0.10] vs. 12.64 mm [SD 4.34], p-value 1e-6) compared with freehand calibration. The use of a ChArUco pattern yielded slightly lower reprojection errors, while a dot grid produced lower reconstruction errors and was more robust under strong global illumination. CONCLUSION: The use of the calibration rig results in a statistically significant decrease in calibration error metrics, versus freehand calibration, and represents the preferred approach for use in the operating theater.


Assuntos
Calibragem , Processamento de Imagem Assistida por Computador , Laparoscópios , Laparoscópios/normas , Laparoscopia/instrumentação , Confiabilidade dos Dados , Dispositivos Ópticos/normas
6.
Int J Comput Assist Radiol Surg ; 17(5): 961-963, 2022 May.
Artigo em Inglês | MEDLINE | ID: mdl-35355211

RESUMO

PURPOSE: The use of synthetic or simulated data has the potential to greatly improve the availability and volume of training data for image guided surgery and other medical applications, where access to real-life training data is limited. METHODS: By using the Unity game engine, complex intraoperative scenes can be simulated. The Unity Perception package allows for randomisation of paremeters within the scene, and automatic labelling, to make simulating large data sets a trivial operation. In this work, the approach has been prototyped for liver segmentation from laparoscopic video images. 50,000 simulated images were used to train a U-Net, without the need for any manual labelling. The use of simulated data was compared against a model trained with 950 manually labelled laparoscopic images. RESULTS: When evaluated on data from 10 separate patients, synthetic data outperformed real data in 4 out of 10 cases. Average DICE scores across the 10 cases were 0.59 (synthetic data), 0.64 (real data) and 0.75 (both synthetic and real data). CONCLUSION: Synthetic data generated using this method is able to make valid inferences on real data, with average performance slightly below models trained on real data. The use of the simulated data for pre-training boosts model performance, when compared with training on real data only.


Assuntos
Aprendizado Profundo , Cirurgia Assistida por Computador , Simulação por Computador , Humanos , Processamento de Imagem Assistida por Computador , Fígado
7.
J Open Res Softw ; 9(1): 17, 2021 Jul 16.
Artigo em Inglês | MEDLINE | ID: mdl-34434553

RESUMO

CMakeCatchTemplate (https://github.com/MattClarkson/CMakeCatchTemplate) is a project to provide a starting structure for C++ projects configured with CMake, that can be customised to work in a variety of scenarios, allowing developers to deploy new algorithms to users in a shorter timeframe. Main features include a SuperBuild to build optional dependencies; unit tests using Catch; support for CUDA, OpenMP and MPI; examples of command line and GUI applications; Doxygen integration; Continuous Integration templates and support for building/deploying Python modules.

8.
Int J Comput Assist Radiol Surg ; 16(8): 1347-1356, 2021 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-33937966

RESUMO

PURPOSE: Image-guided surgery (IGS) is an integral part of modern neuro-oncology surgery. Navigated ultrasound provides the surgeon with reconstructed views of ultrasound data, but no commercial system presently permits its integration with other essential non-imaging-based intraoperative monitoring modalities such as intraoperative neuromonitoring. Such a system would be particularly useful in skull base neurosurgery. METHODS: We established functional and technical requirements of an integrated multi-modality IGS system tailored for skull base surgery with the ability to incorporate: (1) preoperative MRI data and associated 3D volume reconstructions, (2) real-time intraoperative neurophysiological data and (3) live reconstructed 3D ultrasound. We created an open-source software platform to integrate with readily available commercial hardware. We tested the accuracy of the system's ultrasound navigation and reconstruction using a polyvinyl alcohol phantom model and simulated the use of the complete navigation system in a clinical operating room using a patient-specific phantom model. RESULTS: Experimental validation of the system's navigated ultrasound component demonstrated accuracy of [Formula: see text] and a frame rate of 25 frames per second. Clinical simulation confirmed that system assembly was straightforward, could be achieved in a clinically acceptable time of [Formula: see text] and performed with a clinically acceptable level of accuracy. CONCLUSION: We present an integrated open-source research platform for multi-modality IGS. The present prototype system was tailored for neurosurgery and met all minimum design requirements focused on skull base surgery. Future work aims to optimise the system further by addressing the remaining target requirements.


Assuntos
Monitorização Intraoperatória/métodos , Procedimentos Neurocirúrgicos/métodos , Imagens de Fantasmas , Base do Crânio/cirurgia , Cirurgia Assistida por Computador/métodos , Humanos , Imageamento por Ressonância Magnética , Base do Crânio/diagnóstico por imagem , Software , Ultrassonografia
9.
J Open Res Softw ; 8(1): 8, 2020.
Artigo em Inglês | MEDLINE | ID: mdl-32395246

RESUMO

SnappySonic provides an ultrasound acquisition replay simulator designed for public engagement and training. It provides a simple interface to allow users to experience ultrasound acquisition without the need for specialist hardware or acoustically compatible phantoms. The software is implemented in Python, built on top of a set of open source Python modules targeted at surgical innovation. The library has high potential for reuse, most obviously for those who want to simulate ultrasound acquisition, but it could also be used as a user interface for displaying high dimensional images or video data.

10.
Int J Comput Assist Radiol Surg ; 15(7): 1075-1084, 2020 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-32436132

RESUMO

PURPOSE: This paper introduces the SciKit-Surgery libraries, designed to enable rapid development of clinical applications for image-guided interventions. SciKit-Surgery implements a family of compact, orthogonal, libraries accompanied by robust testing, documentation, and quality control. SciKit-Surgery libraries can be rapidly assembled into testable clinical applications and subsequently translated to production software without the need for software reimplementation. The aim is to support translation from single surgeon trials to multicentre trials in under 2 years. METHODS: At the time of publication, there were 13 SciKit-Surgery libraries provide functionality for visualisation and augmented reality in surgery, together with hardware interfaces for video, tracking, and ultrasound sources. The libraries are stand-alone, open source, and provide Python interfaces. This design approach enables fast development of robust applications and subsequent translation. The paper compares the libraries with existing platforms and uses two example applications to show how SciKit-Surgery libraries can be used in practice. RESULTS: Using the number of lines of code and the occurrence of cross-dependencies as proxy measurements of code complexity, two example applications using SciKit-Surgery libraries are analysed. The SciKit-Surgery libraries demonstrate ability to support rapid development of testable clinical applications. By maintaining stricter orthogonality between libraries, the number, and complexity of dependencies can be reduced. The SciKit-Surgery libraries also demonstrate the potential to support wider dissemination of novel research. CONCLUSION: The SciKit-Surgery libraries utilise the modularity of the Python language and the standard data types of the NumPy package to provide an easy-to-use, well-tested, and extensible set of tools for the development of applications for image-guided interventions. The example application built on SciKit-Surgery has a simpler dependency structure than the same application built using a monolithic platform, making ongoing clinical translation more feasible.


Assuntos
Realidade Aumentada , Software , Cirurgia Assistida por Computador/métodos , Humanos
11.
Sci Data ; 5: 180112, 2018 07 03.
Artigo em Inglês | MEDLINE | ID: mdl-29969115

RESUMO

Electrical Impedance Tomography (EIT) is a non-invasive imaging technique, which has the potential to expedite the differentiation of ischaemic or haemorrhagic stroke, decreasing the time to treatment. Whilst demonstrated in simulation, there are currently no suitable imaging or classification methods which can be successfully applied to human stroke data. Development of these complex methods is hindered by a lack of quality Multi-Frequency EIT (MFEIT) data. To address this, MFEIT data were collected from 23 stroke patients, and 10 healthy volunteers, as part of a clinical trial in collaboration with the Hyper Acute Stroke Unit (HASU) at University College London Hospital (UCLH). Data were collected at 17 frequencies between 5 Hz and 2 kHz, with 31 current injections, yielding 930 measurements at each frequency. This dataset is the most comprehensive of its kind and enables combined analysis of MFEIT, Electroencephalography (EEG) and Computed Tomography (CT) or Magnetic Resonance Imaging (MRI) data in stroke patients, which can form the basis of future research into stroke classification.


Assuntos
Neuroimagem , Acidente Vascular Cerebral , Impedância Elétrica , Eletroencefalografia , Humanos , Acidente Vascular Cerebral/diagnóstico por imagem , Acidente Vascular Cerebral/fisiopatologia , Tomografia Computadorizada por Raios X
12.
Physiol Meas ; 36(9): 1943-61, 2015 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-26245292

RESUMO

Multifrequency electrical impedance tomography (MFEIT) reconstructs the distribution of conductivity by exploiting the dependence of tissue conductivity on frequency. MFEIT can be performed on a single instance of data, making it promising for applications such as stroke and cancer imaging, where it is not possible to obtain a 'baseline' measurement of healthy tissue. A nonlinear MFEIT algorithm able to reconstruct the volume fraction distribution of tissue rather than conductivities has been developed previously. For each volume, the fraction of a certain tissue should be either 1 or 0; this implies that the sharp changes of the fractions, representing the boundaries of tissue, contain all the relevant information. However, these boundaries are blurred by traditional regularization methods using [Formula: see text] norm. The total variation (TV) regularization can overcome this problem, but it is difficult to solve due to its non-differentiability. Because the fraction must be between 0 and 1, this imposes a constraint on the MFEIT method based on the fraction model. Therefore, a constrained optimization method capable of dealing with non-differentiable problems is required. Based on the primal and dual interior point method, we propose a new constrained TV regularized method to solve the fraction reconstruction problem. The noise performance of the new MFEIT method is analysed using simulations on a 2D cylindrical mesh. Convergence performance is also analysed through experiments using a cylindrical tank. Finally, simulations on an anatomically realistic head-shaped mesh are demonstrated. The proposed MFEIT method with TV regularization shows higher spatial resolution, particularly at the edges of the perturbation, and stronger noise robustness, and its image noise and shape error are 20% to 30% lower than the traditional fraction method.


Assuntos
Algoritmos , Tomografia/métodos , Simulação por Computador , Impedância Elétrica , Análise de Elementos Finitos , Cabeça/fisiologia , Humanos , Modelos Biológicos , Dinâmica não Linear , Imagens de Fantasmas , Tomografia/instrumentação
13.
Physiol Meas ; 36(6): 1193-209, 2015 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-26008768

RESUMO

The applications of total variation (TV) algorithms for electrical impedance tomography (EIT) have been investigated. The use of the TV regularisation technique helps to preserve discontinuities in reconstruction, such as the boundaries of perturbations and sharp changes in conductivity, which are unintentionally smoothed by traditional l2 norm regularisation. However, the non-differentiability of TV regularisation has led to the use of different algorithms. Recent advances in TV algorithms such as the primal dual interior point method (PDIPM), the linearised alternating direction method of multipliers (LADMM) and the spilt Bregman (SB) method have all been demonstrated successful EIT applications, but no direct comparison of the techniques has been made. Their noise performance, spatial resolution and convergence rate applied to time difference EIT were studied in simulations on 2D cylindrical meshes with different noise levels, 2D cylindrical tank and 3D anatomically head-shaped phantoms containing vegetable material with complex conductivity. LADMM had the fastest calculation speed but worst resolution due to the exclusion of the second-derivative; PDIPM reconstructed the sharpest change in conductivity but with lower contrast than SB; SB had a faster convergence rate than PDIPM and the lowest image errors.


Assuntos
Algoritmos , Processamento de Imagem Assistida por Computador/métodos , Tomografia , Impedância Elétrica , Imagens de Fantasmas , Fatores de Tempo
14.
IEEE Trans Neural Netw Learn Syst ; 23(10): 1513-25, 2012 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-24807998

RESUMO

A compact implementation of a dynamic charge transfer synapse cell, capable of implementing synaptic depression, is presented. The cell is combined with a simple current mirror summing node to produce biologically plausible postsynaptic potentials (PSPs). A single charge packet is effectively transferred from the synapse to the summing node, whenever a presynaptic pulse is applied to one of its terminals. The charge packet is "weighted" by a voltage applied to the second terminal of the synapse. A voltage applied to the third terminal determines the charge recovery time in the synapse, which can be adjusted over several orders of magnitude. This voltage determines the paired pulse ratio for the synapse. The fall time of the PSP is also adjustable and is set by the gate voltage of a metal-oxide-semiconductor field-effect transistor operating in subthreshold. Results extracted from chips fabricated in a 0.35-µm complementary metal-oxide-semiconductor process, alongside theoretical and simulation results, confirm the ability of the cell to produce PSPs that are characteristic of real synapses. The concept addresses a key requirement for scalable hardware neural networks.


Assuntos
Biomimética/instrumentação , Inibição Neural/fisiologia , Sinapses/fisiologia , Potenciais Sinápticos/fisiologia , Transmissão Sináptica/fisiologia , Transistores Eletrônicos , Animais , Desenho de Equipamento , Análise de Falha de Equipamento , Humanos , Modelos Neurológicos , Neurônios
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA