Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 10 de 10
Filtrar
Mais filtros

Base de dados
País/Região como assunto
Tipo de documento
Assunto da revista
País de afiliação
Intervalo de ano de publicação
1.
J Phys Chem A ; 126(40): 7309-7330, 2022 Oct 13.
Artigo em Inglês | MEDLINE | ID: mdl-36170568

RESUMO

Dark chamber experiments were conducted to study the SOA formed from the oxidation of α-pinene and Δ-carene under different peroxy radical (RO2) fate regimes: RO2 + NO3, RO2 + RO2, and RO2 + HO2. SOA mass yields from α-pinene oxidation were <1 to ∼25% and strongly dependent on available OA mass up to ∼100 µg m-3. The strong yield dependence of α-pinene oxidation is driven by absorptive partitioning to OA and not by available surface area for condensation. Yields from Δ-carene + NO3 were consistently higher, ranging from ∼10-50% with some dependence on OA for <25 µg m-3. Explicit kinetic modeling including vapor wall losses was conducted to enable comparisons across VOC precursors and RO2 fate regimes and to determine atmospherically relevant yields. Furthermore, SOA yields were similar for each monoterpene across the nominal RO2 + NO3, RO2 + RO2, or RO2 + HO2 regimes; thus, the volatility basis sets (VBS) constructed were independent of the chemical regime. Elemental O/C ratios of ∼0.4-0.6 and nitrate/organic mass ratios of ∼0.15 were observed in the particle phase for both monoterpenes in all regimes, using aerosol mass spectrometer (AMS) measurements. An empirical relationship for estimating particle density using AMS-derived elemental ratios, previously reported in the literature for non-nitrate containing OA, was successfully adapted to organic nitrate-rich SOA. Observations from an NO3- chemical ionization mass spectrometer (NO3-CIMS) suggest that Δ-carene more readily forms low-volatility gas-phase highly oxygenated molecules (HOMs) than α-pinene, which primarily forms volatile and semivolatile species, when reacted with NO3, regardless of RO2 regime. The similar Δ-carene SOA yields across regimes, high O/C ratios, and presence of HOMs, suggest that unimolecular and multistep processes such as alkoxy radical isomerization and decomposition may play a role in the formation of SOA from Δ-carene + NO3. The scarcity of peroxide functional groups (on average, 14% of C10 groups carried a peroxide functional group in one test experiment in the RO2 + RO2 regime) appears to rule out a major role for autoxidation and organic peroxide (ROOH, ROOR) formation. The consistently substantially lower SOA yields observed for α-pinene + NO3 suggest such pathways are less available for this precursor. The marked and robust regime-independent difference in SOA yield from two different precursor monoterpenes suggests that in order to accurately model SOA production in forested regions the chemical mechanism must feature some distinction among different monoterpenes.

2.
Nature ; 514(7522): 351-4, 2014 Oct 16.
Artigo em Inglês | MEDLINE | ID: mdl-25274311

RESUMO

The United States is now experiencing the most rapid expansion in oil and gas production in four decades, owing in large part to implementation of new extraction technologies such as horizontal drilling combined with hydraulic fracturing. The environmental impacts of this development, from its effect on water quality to the influence of increased methane leakage on climate, have been a matter of intense debate. Air quality impacts are associated with emissions of nitrogen oxides (NOx = NO + NO2) and volatile organic compounds (VOCs), whose photochemistry leads to production of ozone, a secondary pollutant with negative health effects. Recent observations in oil- and gas-producing basins in the western United States have identified ozone mixing ratios well in excess of present air quality standards, but only during winter. Understanding winter ozone production in these regions is scientifically challenging. It occurs during cold periods of snow cover when meteorological inversions concentrate air pollutants from oil and gas activities, but when solar irradiance and absolute humidity, which are both required to initiate conventional photochemistry essential for ozone production, are at a minimum. Here, using data from a remote location in the oil and gas basin of northeastern Utah and a box model, we provide a quantitative assessment of the photochemistry that leads to these extreme winter ozone pollution events, and identify key factors that control ozone production in this unique environment. We find that ozone production occurs at lower NOx and much larger VOC concentrations than does its summertime urban counterpart, leading to carbonyl (oxygenated VOCs with a C = O moiety) photolysis as a dominant oxidant source. Extreme VOC concentrations optimize the ozone production efficiency of NOx. There is considerable potential for global growth in oil and gas extraction from shale. This analysis could help inform strategies to monitor and mitigate air quality impacts and provide broader insight into the response of winter ozone to primary pollutants.

3.
Environ Sci Technol ; 53(5): 2529-2538, 2019 03 05.
Artigo em Inglês | MEDLINE | ID: mdl-30698424

RESUMO

Biomass burning (BB) is a large source of reactive compounds in the atmosphere. While the daytime photochemistry of BB emissions has been studied in some detail, there has been little focus on nighttime reactions despite the potential for substantial oxidative and heterogeneous chemistry. Here, we present the first analysis of nighttime aircraft intercepts of agricultural BB plumes using observations from the NOAA WP-3D aircraft during the 2013 Southeast Nexus (SENEX) campaign. We use these observations in conjunction with detailed chemical box modeling to investigate the formation and fate of oxidants (NO3, N2O5, O3, and OH) and BB volatile organic compounds (BBVOCs), using emissions representative of agricultural burns (rice straw) and western wildfires (ponderosa pine). Field observations suggest NO3 production was approximately 1 ppbv hr-1, while NO3 and N2O5 were at or below 3 pptv, indicating rapid NO3/N2O5 reactivity. Model analysis shows that >99% of NO3/N2O5 loss is due to BBVOC + NO3 reactions rather than aerosol uptake of N2O5. Nighttime BBVOC oxidation for rice straw and ponderosa pine fires is dominated by NO3 (72, 53%, respectively) but O3 oxidation is significant (25, 43%), leading to roughly 55% overnight depletion of the most reactive BBVOCs and NO2.


Assuntos
Atmosfera , Incêndios , Aerossóis , Aeronaves , Biomassa
4.
Faraday Discuss ; 200: 529-557, 2017 08 24.
Artigo em Inglês | MEDLINE | ID: mdl-28580969

RESUMO

Cavity enhanced spectroscopy, CES, is a high sensitivity direct absorption method that has seen increasing utility in the last decade, a period also marked by increasing requirements for understanding human impacts on atmospheric composition. This paper describes the current NOAA six channel cavity ring-down spectrometer (CRDS, the most common form of CES) for measurement of nitrogen oxides and O3. It further describes the results from measurements from a tower 300 m above the urban area of Seoul in late spring of 2015. The campaign demonstrates the performance of the CRDS instrument and provides new data on both photochemistry and nighttime chemistry in a major Asian megacity. The instrument provided accurate, high time resolution data for N2O5, NO, NO2, NOy and O3, but suffered from large wall loss in the sampling of NO3, illustrating the requirement for calibration of the NO3 inlet transmission. Both the photochemistry and nighttime chemistry of nitrogen oxides and O3 were rapid in this megacity. Sustained average rates of O3 buildup of 10 ppbv h-1 during recurring morning and early afternoon sea breezes led to a 50 ppbv average daily O3 rise. Nitrate radical production rates, P(NO3), averaged 3-4 ppbv h-1 in late afternoon and early evening, much greater than contemporary data from Los Angeles, a comparable U. S. megacity. These P(NO3) were much smaller than historical data from Los Angeles, however. Nighttime data at 300 m above ground showed considerable variability in high time resolution nitrogen oxide and O3, likely resulting from sampling within gradients in the nighttime boundary layer structure. Apparent nighttime biogenic VOC oxidation rates of several ppbv h-1 were also likely influenced by vertical gradients. Finally, daytime N2O5 mixing ratios of 3-35 pptv were associated with rapid daytime P(NO3) and agreed well with a photochemical steady state calculation.

5.
Environ Sci Technol ; 51(11): 5941-5950, 2017 Jun 06.
Artigo em Inglês | MEDLINE | ID: mdl-28468492

RESUMO

The Salt Lake Valley experiences severe fine particulate matter pollution episodes in winter during persistent cold-air pools (PCAPs). We employ measurements throughout an entire winter from different elevations to examine the chemical and dynamical processes driving these episodes. Whereas primary pollutants such as NOx and CO were enhanced twofold during PCAPs, O3 concentrations were approximately threefold lower. Atmospheric composition varies strongly with altitude within a PCAP at night with lower NOx and higher oxidants (O3) and oxidized reactive nitrogen (N2O5) aloft. We present observations of N2O5 during PCAPs that provide evidence for its role in cold-pool nitrate formation. Our observations suggest that nighttime and early morning chemistry in the upper levels of a PCAP plays an important role in aerosol nitrate formation. Subsequent daytime mixing enhances surface PM2.5 by dispersing the aerosol throughout the PCAP. As pollutants accumulate and deplete oxidants, nitrate chemistry becomes less active during the later stages of the pollution episodes. This leads to distinct stages of PM2.5 pollution episodes, starting with a period of PM2.5 buildup and followed by a period with plateauing concentrations. We discuss the implications of these findings for mitigation strategies.


Assuntos
Poluentes Atmosféricos , Material Particulado , Temperatura Baixa , Monitoramento Ambiental , Lagos , Utah
6.
Environ Sci Technol ; 51(20): 11761-11770, 2017 Oct 17.
Artigo em Inglês | MEDLINE | ID: mdl-28976736

RESUMO

We report enhancements of glyoxal and methylglyoxal relative to carbon monoxide and formaldehyde in agricultural biomass burning plumes intercepted by the NOAA WP-3D aircraft during the 2013 Southeast Nexus and 2015 Shale Oil and Natural Gas Nexus campaigns. Glyoxal and methylglyoxal were measured using broadband cavity enhanced spectroscopy, which for glyoxal provides a highly selective and sensitive measurement. While enhancement ratios of other species such as methane and formaldehyde were consistent with previous measurements, glyoxal enhancements relative to carbon monoxide averaged 0.0016 ± 0.0009, a factor of 4 lower than values used in global models. Glyoxal enhancements relative to formaldehyde were 30 times lower than previously reported, averaging 0.038 ± 0.02. Several glyoxal loss processes such as photolysis, reactions with hydroxyl radicals, and aerosol uptake were found to be insufficient to explain the lower measured values of glyoxal relative to other biomass burning trace gases, indicating that glyoxal emissions from agricultural biomass burning may be significantly overestimated. Methylglyoxal enhancements were three to six times higher than reported in other recent studies, but spectral interferences from other substituted dicarbyonyls introduce an estimated correction factor of 2 and at least a 25% uncertainty, such that accurate measurements of the enhancements are difficult.


Assuntos
Agroquímicos , Glioxal , Compostos Orgânicos , Aeronaves , Biomassa , Monitoramento Ambiental , Aldeído Pirúvico
7.
Nature ; 464(7286): 271-4, 2010 Mar 11.
Artigo em Inglês | MEDLINE | ID: mdl-20220847

RESUMO

Halogen atoms and oxides are highly reactive and can profoundly affect atmospheric composition. Chlorine atoms can decrease the lifetimes of gaseous elemental mercury and hydrocarbons such as the greenhouse gas methane. Chlorine atoms also influence cycles that catalytically destroy or produce tropospheric ozone, a greenhouse gas potentially toxic to plant and animal life. Conversion of inorganic chloride into gaseous chlorine atom precursors within the troposphere is generally considered a coastal or marine air phenomenon. Here we report mid-continental observations of the chlorine atom precursor nitryl chloride at a distance of 1,400 km from the nearest coastline. We observe persistent and significant nitryl chloride production relative to the consumption of its nitrogen oxide precursors. Comparison of these findings to model predictions based on aerosol and precipitation composition data from long-term monitoring networks suggests nitryl chloride production in the contiguous USA alone is at a level similar to previous global estimates for coastal and marine regions. We also suggest that a significant fraction of tropospheric chlorine atoms may arise directly from anthropogenic pollutants.


Assuntos
Atmosfera/química , Cloro/química , Nitritos/química , Nitrogênio/química , Aerossóis/química , Ar/análise , Colorado , Modelos Químicos , Nitritos/análise , Óxidos de Nitrogênio/química , Fatores de Tempo
8.
Environ Sci Technol ; 48(16): 9609-15, 2014 Aug 19.
Artigo em Inglês | MEDLINE | ID: mdl-25019919

RESUMO

We present a sensitive, compact detector that measures total reactive nitrogen (NOy), as well as NO2, NO, and O3. In all channels, NO2 is directly detected by laser diode based cavity ring-down spectroscopy (CRDS) at 405 nm. Ambient O3 is converted to NO2 in excess NO for the O3 measurement channel. Likewise, ambient NO is converted to NO2 in excess O3. Ambient NOy is thermally dissociated at ∼700 °C to form NO2 or NO in a heated quartz inlet. Any NO present in ambient air or formed from thermal dissociation of other reactive nitrogen compounds is converted to NO2 in excess O3 after the thermal converter. We measured thermal dissociation profiles for six of the major NOy components and compared ambient measurements with other instruments during field campaigns in Utah and Alabama. Alabama measurements were made in a rural location with high biogenic emissions, and Utah measurements were made in the wintertime in unusual conditions that form high ozone levels from emissions related to oil and gas production. The NOy comparison in Alabama, to an accepted standard measurement method (a molybdenum catalytic converter/chemiluminescence instrument), agreed to within 12%, which we define as an upper limit to the accuracy of the NOy channel. The 1σ precision is <30 pptv at 1 s and <4 pptv at 1 min time resolution for all measurement channels. The accuracy is 3% for the NO2 and O3 channels and 5% for the NO channel. The precision and accuracy of this instrument make it a versatile alternative to standard chemiluminescence-based NOy instruments.


Assuntos
Monitoramento Ambiental/métodos , Nitrogênio/análise , Ozônio/análise , Análise Espectral/métodos , Alabama , Monitoramento Ambiental/instrumentação , Desenho de Equipamento , Umidade , Lasers Semicondutores , Dióxido de Nitrogênio/análise , Óxidos de Nitrogênio/análise , Compostos Orgânicos , Análise Espectral/instrumentação , Utah
9.
Anal Chem ; 80(15): 6010-7, 2008 Aug 01.
Artigo em Inglês | MEDLINE | ID: mdl-18588318

RESUMO

Pulsed cavity ring-down spectroscopy is a highly sensitive method for direct absorption spectroscopy that has been applied to in situ detection of NO3, N2O5 and NO2 in the atmosphere from a variety of platforms, including ships, aircraft, and towers. In this paper, we report the development of schemes to significantly improve the accuracy of these measurements. This includes the following: (1) an overall improvement in the inlet transmission efficiencies (92 +/- 2% for NO3 and 97 +/- 1% for N2O5) achieved primarily through a reduction in the inlet residence time; and (2) the development of a calibration procedure that allows regular determination of these efficiencies in the field by addition of NO3 or N2O5 to the inlet from a portable source followed by conversion of NO3 to NO2. In addition, the dependence of the instrument's sensitivity and accuracy to a variety of conditions encountered in the field, including variations in relative humidity, aerosol loading, and VOC levels, was systematically investigated. The rate of degradation of N2O5 transmission efficiency on the inlet and filter system due to the accumulation of inorganic aerosol was determined, such that the frequency of filter changes required for accurate measurements could be defined. In the absence of aerosol, the presence of varying levels of relative humidity and reactive VOC were found to be unimportant factors in the instrument's performance. The 1 sigma accuracy of the NO3, N2O5, and NO2 measured with this instrument are -9/+12, -8/+11, +/- 6%, respectively, where the -/+ signs indicate that the actual value is low/high relative to the measurement. The largest contribution to the overall uncertainty is now due to the NO3 absorption cross section rather than the inlet transmission efficiency.

10.
Environ Sci Technol ; 43(20): 7831-6, 2009 Oct 15.
Artigo em Inglês | MEDLINE | ID: mdl-19921901

RESUMO

A sensitive, small detector was developed for atmospheric NO2 and NOx concentration measurements. NO2 is directly detected by laser diode based cavity ring-down spectroscopy (CRDS) at 404 nm. The sum of NO and NO2 (=NOx) is simultaneously measured in a second cavity by quantitative conversion of ambient NO to NO2 in excess ozone. Interferences due to absorption by other trace gases at 404 nm, such as ozone and water vapor, are either negligible or small and are easily quantified. The limit of detection is 22 pptv (2sigma precision) for NO2 at 1 s time resolution. The conversion efficiency of NO to NO2 is 99% in excess O3. The accuracy of the NO2 measurement is mainly limited by the NO2 absorption cross section to +/-3%. Because of the formation of undetectable higher nitrogen oxides in subsequent reactions of NO2 with ozone in the NOx channel, the (1sigma) accuracy of the NOx measurement is increased to approximately +/-5% depending on the level of NOx. The new instrument was designed to be easily deployed in the field with respect to size, weight and consumables. Measurements were validated against a photolysis/chemiluminescence detector during six days of sampling ambient air with colocated inlets. The data sets for NO2, NO and NOx exhibit high correlation and good agreement within the combined accuracies of both methods. Linear fits for all three species give similar slopes of 0.99 in ambient air.


Assuntos
Ar/análise , Monitoramento Ambiental/instrumentação , Dióxido de Nitrogênio/análise , Lasers , Óxido Nítrico/química , Análise Espectral/instrumentação
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA