Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Mais filtros

Base de dados
País/Região como assunto
Ano de publicação
Tipo de documento
País de afiliação
Intervalo de ano de publicação
1.
Surg Technol Int ; 34: 30-34, 2019 May 15.
Artigo em Inglês | MEDLINE | ID: mdl-30472721

RESUMO

BACKGROUND: The growth of laparoscopic surgery has increased the use of laparoscopic electrosurgical devices based on radiofrequency current. Despite an improvement in most post-operative outcomes, the use of these devices can be associated with inadvertent thermal or mechanical injuries, also called accidental punctures and lacerations (APLs). APLs can occur through either operator error or system error, including insulation failure or capacitive coupling resulting in stray energy burns. Our aim was to estimate the incidence and-as a result-the impact of laparoscopic APLs. METHODS: A retrospective analysis of the Healthcare Cost and Utilization Project (HCUP) State Inpatient Database (SID) was performed for 2009 in California (CA) and Florida (FL). ICD-9 codes and current procedural terminology were used to query for five common general surgery procedures: appendectomy, cholecystectomy, fundoplication, gastric bypass, and gastroplasty with these procedures cross-referenced for any secondary procedure at the time of the initial surgery indicative of APLs. The c2 test was used for comparisons where appropriate. RESULTS: Overall, 192,794 primary laparoscopic procedures were identified in the HCUP database in CA and FL in 2009, with a similar procedure frequency distribution between CA and FL. Six hundred ninety-four procedures were complicated by APL. Gastric bypass and fundoplication were more commonly associated with APLs. CONCLUSION: In this retrospective analysis of procedures performed in CA and FL, the estimated incidence of APL was 3.6 per 1000 cases. Patient morbidity and mortality were likely related to both pilot-error injuries and stray energy burns during laparoscopy. Possible solutions to reduce surgical complications from APL include educational programs to reduce pilot error and the incorporation of fail-safe technologies to eliminate stray energy burns, such as active electrode monitoring and use of non-radiofrequency current (true cautery).


Assuntos
Queimaduras/epidemiologia , Laparoscopia/efeitos adversos , Laparoscopia/estatística & dados numéricos , Ablação por Radiofrequência/efeitos adversos , Acidentes/estatística & dados numéricos , Queimaduras/etiologia , California/epidemiologia , Bases de Dados Factuais , Florida/epidemiologia , Humanos , Incidência , Segurança do Paciente/estatística & dados numéricos , Ablação por Radiofrequência/instrumentação , Estudos Retrospectivos
2.
J Laparoendosc Adv Surg Tech A ; 23(5): 456-8, 2013 May.
Artigo em Inglês | MEDLINE | ID: mdl-23578416

RESUMO

INTRODUCTION: Transoral incisionless fundoplication (TIF) has been used for endoscopic treatment of gastroesophageal reflux disease (GERD). Full-thickness polypropylene H-fasteners create a serosa-to-serosa gastroesophageal plication. A certain subset of TIF patients will require subsequent antireflux surgery to achieve adequate reflux control, and it is unknown whether this procedure increases the technical difficulty of laparoscopic Nissen fundoplication for recurrent GERD. PATIENTS AND METHODS: Between 2008 and 2010, patients demonstrating objective evidence of recurrent gastroesophageal reflux following TIF using the Esophyx device (Endogastric Solutions, Redmond, WA) underwent laparoscopic Nissen fundoplication. The study end points included operative time, operative blood loss, gastric or esophageal perforation, and length of hospital stay. RESULTS: In total, 7 patients underwent laparoscopic Nissen fundoplication for recurrent GERD at a median interval of 7 (range, 3-28) months after TIF. Revisional fundoplication required 97 (range, 48-122) minutes and was performed in all cases with minimal blood loss. There were no cases of esophageal or gastric perforation during the dissection of the previous fundoplication. A significant hiatal hernia was noted during 1 case, and all others revealed partially disrupted gastroesophageal fundoplications with visible dislodged polypropylene H-fasteners visible. All patients were discharged from the hospital on the first postoperative day. CONCLUSIONS: Severe recurrent gastroesophageal reflux necessitating laparoscopic Nissen fundoplication occurs in a subset of patients following TIF. In this series, previous TIF did not result in prolonged operative times, significant operative hemorrhage, or iatrogenic hollow viscus injury. These data suggest that laparoscopic Nissen fundoplication can be safely performed in this patient population without increased operative morbidity.


Assuntos
Fundoplicatura/métodos , Refluxo Gastroesofágico/cirurgia , Laparoscopia , Adulto , Idoso , Feminino , Fundoplicatura/efeitos adversos , Humanos , Masculino , Pessoa de Meia-Idade , Boca , Cirurgia Endoscópica por Orifício Natural , Complicações Pós-Operatórias/epidemiologia , Complicações Pós-Operatórias/etiologia , Recidiva , Estudos Retrospectivos , Adulto Jovem
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA