Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 5 de 5
Filtrar
Mais filtros

Base de dados
Ano de publicação
Tipo de documento
Assunto da revista
Intervalo de ano de publicação
1.
Eur J Orthop Surg Traumatol ; 34(5): 2645-2652, 2024 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-38743103

RESUMO

INTRODUCTION: Computerized surgical navigation system guidance can improve bone tumor surgical resection accuracy. This study compared the 10-mm planned resection margin agreement between simulated pelvic-region bone tumors (SPBT) resected using either skin fiducial markers or Kirschner (K)-wires inserted directly into osseous landmarks with navigational system registration under direct observation. We hypothesized that skin fiducial markers would display similar resection margin accuracy. METHODS: Six cadaveric pelvises had one SPBT implanted into each supra-acetabular region. At the left hemi-pelvis, the skin fiducial marker group had guidance from markers placed over the pubic tubercle, the anterior superior iliac spine, the central and more posterior iliac crest, and the greater trochanter (5 markers). At the right hemi-pelvis, the K-wire group had guidance from 1.4-mm-diameter wires inserted into the pubic tubercle, and 3 inserted along the iliac crest (4 K-wires). The senior author, a fellowship-trained surgeon performed "en bloc" SPBT resections. The primary investigator, blinded to group assignment, measured actual resection margins. RESULTS: Twenty of 22 resection margins (91%) in the skin fiducial marker group were within the Bland-Altman plot 95% confidence interval for actual-planned margin mean difference (mean = -0.23 mm; 95% confidence intervals = 2.8 mm, - 3.3 mm). Twenty-one of 22 resection margins (95%) in the K-wire group were within the 95% confidence interval of actual-planned margin mean difference (mean = 0.26 mm; 95% confidence intervals = 1.7 mm, - 1.1 mm). CONCLUSION: Pelvic bone tumor resection with navigational guidance from skin fiducial markers placed over osseous landmarks provided similar accuracy to K-wires inserted into osseous landmarks. Further in vitro studies with different SPBT dimensions/locations and clinical studies will better delineate use efficacy.


Assuntos
Neoplasias Ósseas , Cadáver , Marcadores Fiduciais , Margens de Excisão , Ossos Pélvicos , Cirurgia Assistida por Computador , Humanos , Cirurgia Assistida por Computador/métodos , Neoplasias Ósseas/cirurgia , Neoplasias Ósseas/patologia , Neoplasias Ósseas/diagnóstico por imagem , Ossos Pélvicos/cirurgia , Ossos Pélvicos/diagnóstico por imagem , Fios Ortopédicos , Pontos de Referência Anatômicos , Feminino , Ílio/cirurgia , Masculino
3.
Cureus ; 16(3): e57028, 2024 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-38681386

RESUMO

Background Vitamin D has been found to be crucial in musculoskeletal health. The role of vitamin D levels in orthopedic patients has become a growing area of interest given its negative impact on fracture healing which can contribute to the development of nonunion following surgery. We sought to investigate the incidence of hypovitaminosis D in a cohort of patients who experienced a nonunion following a foot and ankle arthrodesis procedure. Methodology Patients who underwent a major elective foot and ankle arthrodesis procedure and developed a nonunion were given the opportunity to obtain serum vitamin D levels. All vitamin D levels were reported from percutaneous venous blood samples and compared to our institution's range of accepted normal values (25-80 ng/mL). Results A total of 13 patients who developed a nonunion agreed to have a vitamin D level obtained, and 11 of 13 patients had a low vitamin D level (average = 14.6 ng/mL, range = 9-24 ng/mL). Five patients underwent revision arthrodesis after normalization of vitamin D levels, and four out of five patients went on to successful union. Conclusions Hypovitaminosis D may be a modifiable risk factor for nonunion following a major foot and ankle arthrodesis procedure. Orthopedic surgeons should consider vitamin D screening and supplementation in patients undergoing elective arthrodesis procedures.

4.
Foot Ankle Int ; 45(8): 888-895, 2024 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-38853769

RESUMO

BACKGROUND: Operative management of midfoot Charcot arthropathy often involves an extended midfoot arthrodesis with intramedullary bolts for fixation, a method called "beaming." Recently intramedullary nails have been introduced for the same indication, presumably providing stronger fixation. This study compares midfoot fusion nails to bolts with regard to stiffness and compressive ability. Additionally, we assessed how the addition of a subtalar fusion affects the construct. METHODS: Medial column fusions were performed on 10 matched cadaver foot specimens with either a midfoot fusion nail or bolt. Specimens underwent cyclical compression loading, and displacement was measured. Separately, compressive forces produced were compared between the 2 fixation constructs using a synthetic bone block model. Lastly, another 10 matched specimens with midfoot fusion nails were evaluated with or without subtalar fusions. RESULTS: No differences in stiffness were found in comparing matched specimens between nail vs bolt or comparing nail only without subtalar fusion (STF) vs nail with STF. The compressive force produced by the nail specimens was significantly and substantially greater than the bolted specimens (751.7 vs 139.0 N, P = .01). The accumulated height drop at the midfoot after cycling was 0.5 mm more in the nail group than in the bolt group (1.72 vs 1.22 mm, P = .008). The nail with STF group had greater initial height drop at the midfoot than the nail-only group (0.68 vs 0.34 mm, P = .035) with similar initial height drop at the ankle. However, there were no differences in strength among the matched pairs of midfoot nail-only vs midfoot nail with STF as measured by displacement after fatigue or maximum force at load to failure. CONCLUSION: The overall cadaveric comparisons between matched pairs of nails vs bolts, and nail-only vs nail with STF, did not provide noteworthy differences between the groups with regard to strength or stiffness. However, the compressive force of the midfoot fusion nail was far superior to the bolt in a synthetic bone model. These data provide valuable insight comparing implants used in Charcot midfoot arthrodesis.


Assuntos
Artrodese , Pinos Ortopédicos , Cadáver , Força Compressiva , Humanos , Artrodese/métodos , Artrodese/instrumentação , Artropatia Neurogênica/cirurgia , Artropatia Neurogênica/fisiopatologia , Articulação Talocalcânea/cirurgia , Idoso
5.
Int Forum Allergy Rhinol ; 9(10): 1144-1150, 2019 10.
Artigo em Inglês | MEDLINE | ID: mdl-31430061

RESUMO

BACKGROUND: The Questionnaire of Olfactory Disorders-Negative Statements (QOD-NS) is a valuable instrument in the measurement of olfactory-specific quality of life (QOL). In the clinical setting, patients can be overwhelmed with the time required to complete questionnaires. Our objective was to develop a brief version of the QOD-NS to streamline clinical care and research. METHODS: QOD-NS scores from 221 subjects were used to determine which subset of the 17 QOD-NS questions best correlated with total and subdomain QOD-NS scores. An initial pool of 11 questions was made by removing items with ρ < 0.80 to their respective subdomain scores. Next, 500 bootstrapped samples were taken. On each sampe, an all-subsets regression was performed with total QOD-NS scores and QOD-NS subdomain scores as the outcomes. From this, our "top" and "bottom" 10 subsets were identified based on mean r2 value, representation in bootstrap analysis, and number of items. RESULTS: All of our top subsets had excellent correlation with total and subdomain QOD-NS scores (mean r2 > 0.90). Our top choice has 7 total questions, is representative of all subdomains, has a mean r2 = 0.92, and was represented in 323 of our 500 bootstrapped samples. The worst-performing subset has 5 items, mean r2 = 0.81, and was represented in only 1 bootstrapped sample. CONCLUSIONS: Using less than half of the questions in the QOD-NS, excellent correlations with both total and domain-specific scores are achieved. A brief version of the QOD-NS may prove useful in future clinical and research settings.


Assuntos
Transtornos do Olfato/diagnóstico , Rinite/diagnóstico , Sinusite/diagnóstico , Inquéritos e Questionários , Adulto , Idoso , Doença Crônica , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Qualidade de Vida
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA