RESUMO
Circumferential scanning in endoscopic imaging is crucial across various disciplines, and optical coherence tomography (OCT) is often the preferred choice due to its high-speed, high-resolution, and micron-scale imaging capabilities. Moreover, real-time and high-speed 3D endoscopy is a pivotal technology for medical screening and precise surgical guidance, among other applications. However, challenges such as image jitter and non-uniform rotational distortion (NURD) are persistent obstacles that hinder real-time visualization during high-speed OCT procedures. To address this issue, we developed an innovative, low-cost endoscope that employs a brushless DC motor for scanning, and a sensorless technique for triggering and synchronizing OCT imaging with the scanning motor. This sensorless approach uses the motor's electrical feedback (back electromotive force, BEMF) as a virtual Hall sensor to initiate OCT image acquisition and synchronize it with a Fourier Domain Mode-Locked (FDML)-based Megahertz OCT system. Notably, the implementation of BEMF-triggered OCT has led to a substantial reduction in image jitter and NURD (<4 mrad), thereby opening up a new window for real-time visualization capabilities. This approach suggests potential benefits across various applications, aiming to provide a more accurate, deployable, and cost-effective solution. Subsequent studies can explore the adaptability of this system to specific clinical scenarios and its performance under practical endoscopic conditions.
RESUMO
PURPOSE: To evaluate the feasibility and accuracy of a radiation-free implantation of a thoracic aortic stent graft employing fiberoptic and electromagnetic tracking in an anthropomorphic phantom. MATERIALS AND METHODS: An anthropomorphic phantom was manufactured based on computed tomography (CT) angiography data from a patient. An aortic stent graft application system was equipped with a fiber Bragg gratings and 3 electromagnetic sensors. The stent graft was navigated in the phantom by 3 interventionalists using the tracking data generated by both technologies. One implantation procedure was performed. The technical success of the procedure was evaluated using digital subtraction angiography and CT angiography (before and after the intervention). Tracking accuracy was determined at various anatomical landmarks based on separately acquired fluoroscopic images. The mean/maximum errors were measured for the stent graft application system and the tip/end of the stent graft. RESULTS: The procedure resulted in technical success with a mean error below 3 mm for the entire application system and <2 mm for the position of the tip of the stent graft. Navigation/implantation and handling of the device were rated sufficiently accurate and on par with comparable, routinely used stent graft application systems. CONCLUSIONS: The study demonstrates successful stent graft implantation during a thoracic endovascular aortic repair procedure employing advanced guidance techniques and avoiding fluoroscopic imaging. This is an essential step in facilitating the implantation of stent grafts and reducing the health risks associated with ionizing radiation during endovascular procedures.
Assuntos
Aneurisma da Aorta Abdominal , Aneurisma da Aorta Torácica , Implante de Prótese Vascular , Procedimentos Endovasculares , Aneurisma da Aorta Abdominal/cirurgia , Aneurisma da Aorta Torácica/diagnóstico por imagem , Aneurisma da Aorta Torácica/cirurgia , Prótese Vascular , Fenômenos Eletromagnéticos , Humanos , Imageamento Tridimensional , Stents , Resultado do TratamentoRESUMO
We present a forward-viewing fiber scanning endoscope (FSE) for high-speed volumetric optical coherence tomography (OCT). The reduction in size of the probe was achieved by substituting the focusing optics by an all-fiber-based imaging system which consists of a combination of scanning single-mode fibers, a glass spacer, made from a step-index multi-mode fiber, and a gradient-index fiber. A lateral resolution of 11 µm was achieved at a working distance of 1.2 mm. The newly designed piezo-based FSE has an outer diameter of 1.6 mm and a rigid length of 13.5 mm. By moving the whole imaging optic in spirals for scanning the sample, the beam quality remains constant over the entire field of view with a diameter of 0.8 mm. The scanning frequency was adjusted to 1.22 kHz for use with a 3.28 MHz Fourier domain mode locked OCT system. Densely sampled volumes have been imaged at a rate of 6 volumes per second.
RESUMO
OBJECTIVE: Optical coherence elastography (OCE) allows for high resolution analysis of elastic tissue properties. However, due to the limited penetration of light into tissue, miniature probes are required to reach structures inside the body, e.g., vessel walls. Shear wave elastography relates shear wave velocities to quantitative estimates of elasticity. Generally, this is achieved by measuring the runtime of waves between two or multiple points. For miniature probes, optical fibers have been integrated and the runtime between the point of excitation and a single measurement point has been considered. This approach requires precise temporal synchronization and spatial calibration between excitation and imaging. METHODS: We present a miniaturized dual-fiber OCE probe of 1 mm diameter allowing for robust shear wave elastography. Shear wave velocity is estimated between two optics and hence independent of wave propagation between excitation and imaging. We quantify the wave propagation by evaluating either a single or two measurement points. Particularly, we compare both approaches to ultrasound elastography. RESULTS: Our experimental results demonstrate that quantification of local tissue elasticities is feasible. For homogeneous soft tissue phantoms, we obtain mean deviations of 0.15 ms-1 and 0.02 ms-1 for single-fiber and dual-fiber OCE, respectively. In inhomogeneous phantoms, we measure mean deviations of up to 0.54 ms-1 and 0.03 ms-1 for single-fiber and dual-fiber OCE, respectively. CONCLUSION: We present a dual-fiber OCE approach that is much more robust in inhomogeneous tissues. Moreover, we demonstrate the feasibility of elasticity quantification in ex-vivo coronary arteries. SIGNIFICANCE: This study introduces an approach for robust elasticity quantification from within the tissue.
RESUMO
Purpose: To assess the efficacy of an instrument-integrated OCT (iiOCT)-based distance sensor during robotic vitreoretinal surgery using the Preceyes Surgical System (PSS; Preceyes B.V.). Design: Single-center interventional study. Participants: Patients requiring vitreoretinal surgery. Methods: Five patients were enrolled. Standard preoperative OCT images were obtained. After vitrectomy, a predefined set of actions was performed using the iiOCT-based sensor. Images then were processed to assess the signal-to-noise ratio (SNR) at various angles to the retina and at different distances between the instrument tip and the retinal surface. Preoperative and intraoperative OCT images were compared qualitatively and quantitatively. Main Outcomes Measures: The feasibility in performing surgical tasks using the iiOCT-based sensor during vitreoretinal surgery, the SNR when imaging the retina, differences among intraoperative and preoperative OCT images, and characteristics of intraoperative retinal movements detected with the iiOCT-based probe. Results: Surgeons were able to perform all the tasks but one. The PSS was able to maintain a fixed distance. The SNR of the iiOCT-based sensor signal was adequate to determine the distance to the retina and to control the PSS. Analysis of iiOCT-based sensor A-scans identified 3 clearly distinguishable retinal layers, including the inner retinal boundary and the interface at the retinal pigment epithelium-Bruch's membrane. Thickness values differed by less than 5% from that measured by preoperative OCT, indicating its accuracy. The Fourier analysis of iiOCT-based sensor recordings identified anteroposterior retinal movements attributed to heartbeat and respiration. Conclusions: This iiOCT-based sensor was tested successfully and promises reliable use during robot-assisted surgery. An iiOCT-based sensor is a promising step toward OCT-guided robotic retinal surgery.
RESUMO
BACKGROUND: In endovascular aneuysm repair (EVAR) procedures, medical instruments are currently navigated with a two-dimensional imaging based guidance requiring X-rays and contrast agent. METHODS: Novel approaches for obtaining the three-dimensional instrument positions are introduced. Firstly, a method based on fibre optical shape sensing, one electromagnetic sensor and a preoperative computed tomography (CT) scan is described. Secondly, an approach based on image processing using one 2D fluoroscopic image and a preoperative CT scan is introduced. RESULTS: For the tracking based method, average errors from 1.81 to 3.13 mm and maximum errors from 3.21 to 5.46 mm were measured. For the image-based approach, average errors from 3.07 to 6.02 mm and maximum errors from 8.05 to 15.75 mm were measured. CONCLUSION: The tracking based method is promising for usage in EVAR procedures. For the image-based approach are applications in smaller vessels more suitable, since its errors increase with the vessel diameter.
Assuntos
Aneurisma da Aorta Abdominal , Implante de Prótese Vascular , Procedimentos Endovasculares , Aneurisma da Aorta Abdominal/diagnóstico por imagem , Aneurisma da Aorta Abdominal/cirurgia , Fluoroscopia , Humanos , Imageamento TridimensionalRESUMO
PURPOSE: During endovascular aneurysm repair (EVAR) procedures, medical instruments are guided with two-dimensional (2D) fluoroscopy and conventional digital subtraction angiography. However, this requires X-ray exposure and contrast agent is used, and the depth information is missing. To overcome these drawbacks, a three-dimensional (3D) guidance approach based on tracking systems is introduced and evaluated. METHODS: A multicore fiber with fiber Bragg gratings for shape sensing and three electromagnetic (EM) sensors for locating the shape were integrated into a stentgraft system. A model for obtaining the located shape of the first 38 cm of the stentgraft system with two EM sensors is introduced and compared with a method based on three EM sensors. Both methods were evaluated with a vessel phantom containing a 3D-printed vessel made of silicone and agar-agar simulating the surrounding tissue. RESULTS: The evaluation of the guidance methods resulted in average errors from 1.35 to 2.43 mm and maximum errors from 3.04 to 6.30 mm using three EM sensors, and average errors from 1.57 to 2.64 mm and maximum errors from 2.79 to 6.27 mm using two EM sensors. Moreover, the videos made from the continuous measurements showed that a real-time guidance is possible with both approaches. CONCLUSION: The results showed that an accurate real-time guidance with two and three EM sensors is possible and that two EM sensors are already sufficient. Thus, the introduced 3D guidance method is promising to use it as navigation tool in EVAR procedures. Future work will focus on developing a method with less EM sensors and a detailed latency evaluation of the guidance method.
Assuntos
Aneurisma Aórtico/cirurgia , Implante de Prótese Vascular/instrumentação , Imageamento Tridimensional/métodos , Angiografia Digital , Procedimentos Endovasculares/métodos , Fluoroscopia , Humanos , Imagens de FantasmasRESUMO
PURPOSE: Endovascular aortic repair procedures are currently conducted with 2D fluoroscopy imaging. Tracking systems based on fiber Bragg gratings are an emerging technology for the navigation of minimally invasive instruments which can reduce the X-ray exposure and the used contrast agent. Shape sensing of flexible structures is challenging and includes many calculations steps which are prone to different errors. To reduce this errors, we present an optimized shape sensing model. METHODS: We analyzed for every step of the shape sensing process, which errors can occur, how the error affects the shape and how it can be compensated or minimized. Experiments were done with one multicore fiber system with 38 cm sensing length, and the effects of different methods and parameters were analyzed. Furthermore, we compared 3D shape reconstructions with the segmented shape of the corresponding CT scans of the fiber to evaluate the accuracy of our optimized shape sensing model. Finally, we tested our model in a realistic endovascular scenario by using a 3D printed vessel system created from patient data. RESULTS: Depending on the complexity of the shape, we reached an average error of 0.35-1.15 mm and maximal error of 0.75-7.53 mm over the whole 38 cm sensing length. In the endovascular scenario, we obtained an average and maximal error of 1.13 mm and 2.11 mm, respectively. CONCLUSION: The accuracies of the 3D shape sensing model are promising, and we plan to combine the shape sensing based on fiber Bragg gratings with the position and orientation of an electromagnetic tracking to obtain the located catheter shape.