J Cardiovasc Electrophysiol ; 34(2): 348-355, 2023 02.
Artigo em Inglês | MEDLINE | ID: mdl-36448428

RESUMO

INTRODUCTION: Early and safe ambulation can facilitate same-day discharge (SDD) following catheter ablation, which can reduce resource utilization and healthcare costs and improve patient satisfaction. This study evaluated procedure success and safety of the VASCADE MVP venous vascular closure system in patients with atrial fibrillation (AF). METHODS: The AMBULATE SDD Registry is a two-stage series of postmarket studies in patients with paroxysmal or persistent AF undergoing catheter ablation followed by femoral venous access-site closure with VASCADE MVP. Efficacy endpoints included SDD success, defined as the proportion of patients discharged the same day who did not require next-day hospital intervention for procedure/access site-related complications, and access site sustained success within 15 days of the procedure. RESULTS: Overall, 354 patients were included in the pooled study population, 151 (42.7%) treated for paroxysmal AF and 203 (57.3%) for persistent AF. SDD was achieved in 323 patients (91.2%) and, of these, 320 (99.1%) did not require subsequent hospital intervention based on all study performance outcomes. Nearly all patients (350 of 354; 98.9%) achieved total study success, with no subsequent hospital intervention required. No major access-site complications were recorded. Patients who had SDD were more likely to report procedure satisfaction than patients who stayed overnight. CONCLUSION: In this study, 99.7% of patients achieving SDD required no additional hospital intervention for access site-related complications during follow-up. SDD appears feasible and safe for eligible patients after catheter ablation for paroxysmal or persistent AF in which the VASCADE MVP is used for venous access-site closure.


Assuntos
Fibrilação Atrial , Ablação por Cateter , Humanos , Alta do Paciente , Fibrilação Atrial/diagnóstico , Fibrilação Atrial/cirurgia , Fibrilação Atrial/etiologia , Satisfação do Paciente , Ablação por Cateter/efeitos adversos , Ablação por Cateter/métodos , Sistema de Registros , Resultado do Tratamento
2.
N Engl J Med ; 380(20): 1895-1905, 2019 05 16.
Artigo em Inglês | MEDLINE | ID: mdl-30883056

RESUMO

BACKGROUND: Infections after placement of cardiac implantable electronic devices (CIEDs) are associated with substantial morbidity and mortality. There is limited evidence on prophylactic strategies, other than the use of preoperative antibiotics, to prevent such infections. METHODS: We conducted a randomized, controlled clinical trial to assess the safety and efficacy of an absorbable, antibiotic-eluting envelope in reducing the incidence of infection associated with CIED implantations. Patients who were undergoing a CIED pocket revision, generator replacement, or system upgrade or an initial implantation of a cardiac resynchronization therapy defibrillator were randomly assigned, in a 1:1 ratio, to receive the envelope or not. Standard-of-care strategies to prevent infection were used in all patients. The primary end point was infection resulting in system extraction or revision, long-term antibiotic therapy with infection recurrence, or death, within 12 months after the CIED implantation procedure. The secondary end point for safety was procedure-related or system-related complications within 12 months. RESULTS: A total of 6983 patients underwent randomization: 3495 to the envelope group and 3488 to the control group. The primary end point occurred in 25 patients in the envelope group and 42 patients in the control group (12-month Kaplan-Meier estimated event rate, 0.7% and 1.2%, respectively; hazard ratio, 0.60; 95% confidence interval [CI], 0.36 to 0.98; P = 0.04). The safety end point occurred in 201 patients in the envelope group and 236 patients in the control group (12-month Kaplan-Meier estimated event rate, 6.0% and 6.9%, respectively; hazard ratio, 0.87; 95% CI, 0.72 to 1.06; P<0.001 for noninferiority). The mean (±SD) duration of follow-up was 20.7±8.5 months. Major CIED-related infections through the entire follow-up period occurred in 32 patients in the envelope group and 51 patients in the control group (hazard ratio, 0.63; 95% CI, 0.40 to 0.98). CONCLUSIONS: Adjunctive use of an antibacterial envelope resulted in a significantly lower incidence of major CIED infections than standard-of-care infection-prevention strategies alone, without a higher incidence of complications. (Funded by Medtronic; WRAP-IT ClinicalTrials.gov number, NCT02277990.).


Assuntos
Antibacterianos/administração & dosagem , Antibioticoprofilaxia , Infecções Bacterianas/prevenção & controle , Desfibriladores Implantáveis/efeitos adversos , Cardiopatias/terapia , Minociclina/administração & dosagem , Marca-Passo Artificial/efeitos adversos , Infecções Relacionadas à Prótese/prevenção & controle , Rifampina/administração & dosagem , Idoso , Antibacterianos/efeitos adversos , Infecções Bacterianas/epidemiologia , Infecções Bacterianas/mortalidade , Feminino , Humanos , Incidência , Estimativa de Kaplan-Meier , Masculino , Pessoa de Meia-Idade , Minociclina/efeitos adversos , Infecções Relacionadas à Prótese/epidemiologia , Infecções Relacionadas à Prótese/mortalidade , Rifampina/efeitos adversos , Método Simples-Cego , Padrão de Cuidado
3.
J Cardiovasc Electrophysiol ; 32(10): 2729-2736, 2021 10.
Artigo em Inglês | MEDLINE | ID: mdl-34374160

RESUMO

BACKGROUND: Patients with wire and catheter refractory venous occlusion are traditionally referred for pectoral transvenous lead extraction (TLE) to obtain venous access. TLE causes 1-2 mm circumferential mechanical or laser destruction of tissue surrounding the lead(s). This not only exposes the patient to the risk of major complications but also can damage nontargeted leads. We present a series of patients where retained wire femoral lead removal and fibroplasty was used to obtain venous access in patients with refractory obstruction. METHODS: Between 2008 and 2021, we identified 17 patients where retained wire lead removal followed by fibroplasty was used to retain venous access. Demographic and procedural data were obtained by retrospective review of patient charts. RESULTS: We were able to successfully obtain venous access in all 17 patients in whom this technique was attempted. In two patients the target lead was less than or equal to 1 year old. In the remaining 15 patients, the average dwell time of the target lead(s) was 6 years. There were no procedure-related complications, and no changes in the parameters of other leads were noted. CONCLUSION: Retained wire femoral lead removal and fibroplasty is safe and highly efficacious at obtaining venous access in patients with refractory venous occlusion. If the target lead(s) is less than or equal to 1 year old, this technique can help obtain venous access at the time of the initial surgery, hence avoiding the need for TLE. Furthermore, in patients referred for TLE to obtain venous access, this technique by avoiding the use of TLE tools spares the patient of the associated risks.


Assuntos
Desfibriladores Implantáveis , Marca-Passo Artificial , Remoção de Dispositivo/efeitos adversos , Artéria Femoral , Humanos , Estudos Retrospectivos
4.
Artigo em Inglês | MEDLINE | ID: mdl-38509402

RESUMO

BACKGROUND: Roughly one in six patients receiving conventional transvenous pacemaker systems experience significant complications within 1 year of implant, mainly due to the transvenous lead and subcutaneous pocket. A new helix-fixation single-chamber ventricular leadless pacemaker (LP) system capable of pre-deployment exploratory electrical mapping is commercially available. Such an LP may mitigate complications while streamlining the implantation. In this study, the initial real-world implant experience of the helix-fixation LP was evaluated following its commercial release. METHODS: In patients indicated for single-chamber right ventricular pacing, helix-fixation Aveir VR LPs (Abbott, Abbott Park, IL) were implanted using the dedicated loading tool, introducer, and delivery catheter. Implant procedural characteristics, electrical parameters, and any 30-day procedure-related adverse events of consecutive implant attempts were retrospectively evaluated. RESULTS: A total of 167 patients with Class I indication for permanent pacing received implants in four North American centers (57% male, 70 years old). Pre-fixation electrical mapping of potential sites allowed repositioning to be avoided in 95.7% of patients. Median [interquartile range] LP procedure and fluoroscopy durations were 25.5 min [20.0, 35.0] and 5.7 min [4.0, 9.2], respectively. Pacing capture threshold, sensed R-wave amplitude, and impedance were 0.8 V [0.5, 1.3], 9.0 mV [6.0, 12.0], and 705 Ω [550, 910], respectively. Implantation was successful in 98.8% of patients, with 98.2% free from acute adverse events. CONCLUSIONS: The initial, real-world experience of the helix-fixation ventricular leadless pacemaker demonstrated safe and efficient implantation with minimal repositioning, viable electrical metrics, and limited acute complications.

5.
J Am Coll Cardiol ; 84(1): 61-74, 2024 07 02.
Artigo em Inglês | MEDLINE | ID: mdl-38864538

RESUMO

BACKGROUND: The ADVENT randomized trial revealed no significant difference in 1-year freedom from atrial arrhythmias (AA) between thermal (radiofrequency/cryoballoon) and pulsed field ablation (PFA). However, recent studies indicate that the postablation AA burden is a better predictor of clinical outcomes than the dichotomous endpoint of 30-second AA recurrence. OBJECTIVES: The goal of this study was to determine: 1) the impact of postablation AA burden on outcomes; and 2) the effect of ablation modality on AA burden. METHODS: In ADVENT, symptomatic drug-refractory patients with paroxysmal atrial fibrillation underwent PFA or thermal ablation. Postablation transtelephonic electrocardiogram monitor recordings were collected weekly or for symptoms, and 72-hour Holters were at 6 and 12 months. AA burden was calculated from percentage AA on Holters and transtelephonic electrocardiogram monitors. Quality-of-life assessments were at baseline and 12 months. RESULTS: From 593 randomized patients (299 PFA, 294 thermal), using aggregate PFA/thermal data, an AA burden exceeding 0.1% was associated with a significantly reduced quality of life and an increase in clinical interventions: redo ablation, cardioversion, and hospitalization. There were more patients with residual AA burden <0.1% with PFA than thermal ablation (OR: 1.5; 95% CI: 1.0-2.3; P = 0.04). Evaluation of outcomes by baseline demographics revealed that patients with prior failed class I/III antiarrhythmic drugs had less residual AA burden after PFA compared to thermal ablation (OR: 2.5; 95% CI: 1.4-4.3; P = 0.002); patients receiving only class II/IV antiarrhythmic drugs pre-ablation had no difference in AA burden between ablation groups. CONCLUSIONS: Compared with thermal ablation, PFA more often resulted in an AA burden less than the clinically significant threshold of 0.1% burden. (The FARAPULSE ADVENT PIVOTAL Trial PFA System vs SOC Ablation for Paroxysmal Atrial Fibrillation [ADVENT]; NCT04612244).


Assuntos
Fibrilação Atrial , Ablação por Cateter , Recidiva , Humanos , Fibrilação Atrial/cirurgia , Fibrilação Atrial/terapia , Fibrilação Atrial/fisiopatologia , Masculino , Feminino , Pessoa de Meia-Idade , Ablação por Cateter/métodos , Idoso , Qualidade de Vida , Resultado do Tratamento
6.
Heart Rhythm ; 19(5): 776-781, 2022 05.
Artigo em Inglês | MEDLINE | ID: mdl-35066177

RESUMO

BACKGROUND: Complications associated with transvenous pacemakers, specifically those involving the lead or subcutaneous pocket, may be avoided with leadless pacemakers (LPs). The safety and efficacy of single-chamber right ventricular LPs have been demonstrated, but their right atrium (RA) use poses new design constraints. OBJECTIVES: The purpose of this study was to evaluate the implant success, electrical performance, and safety of a novel RA LP design in benchtop and preclinical studies. METHODS: A new LP was designed with a dual-helix fixation mechanism specific to the RA anatomy. A 12-week preclinical ovine study was conducted to evaluate implant success, electrical performance, mechanical stability, and safety in vivo, with supporting benchtop measurements to quantify the mechanical forces needed for device retrieval and dislodgment. RESULTS: LPs were successfully implanted in all 10 ovine subjects with no complications. The pacing capture threshold improved significantly over time from implant to week 12 (1.1 ± 0.7 V vs 0.4 ± 0.2 V, P = .008). Sensing amplitudes and pacing impedances were stable from implant to week 12 (4.8 ± 1.8 mV vs 6.0 ± 1.9 mV, P = .160; and 393 ± 77 Ω vs 398 ± 65 Ω, P = .922, respectively). Gross pathology and microscopic histology revealed no adverse interactions and no evidence of device dislodgment or clinically significant myocardial perforation. Benchtop ex vivo porcine atrial tissue measurements revealed greater pull forces required to dislodge the LP vs transvenous active fixation lead (0.42 ± 0.18 lbf vs 0.29 ± 0.08 lbf, P = .020), and greater rotational forces required for deliberate extraction (0.28 ± 0.04 lbf vs 0.14 ± 0.07 lbf, P <.001). CONCLUSION: The novel atrial LP demonstrated successful implantation, with acceptable electrical performance, mechanical stability, and safety in a 12-week preclinical study.


Assuntos
Lipopolissacarídeos , Marca-Passo Artificial , Animais , Estimulação Cardíaca Artificial , Desenho de Equipamento , Átrios do Coração , Humanos , Próteses e Implantes , Ovinos , Suínos , Resultado do Tratamento
7.
Heart Rhythm O2 ; 3(4): 396-404, 2022 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-36097459

RESUMO

Background: Hybrid Convergent ablation for atrial fibrillation (AF) combines minimally invasive surgical (epicardial) and catheter (endocardial) ablation. The procedural goal is to achieve more extensive, enduring ablation of AF substrate around the pulmonary veins, posterior wall, and vestibule of the posterior wall left atrium. Objective: To perform a systematic review and meta-analysis on safety and effectiveness of contemporary Hybrid Convergent procedures. Methods: PubMed, Embase, and manual searches identified primary research articles on Hybrid Convergent. Inclusion criteria focused on contemporary practices (epicardial ablation device and lesions). Clinical outcomes at 1 year or later follow-up, patient population, procedural details, and major adverse events (MAE) were recorded. Results: Of 249 records, 6 studies (5 observational, 1 randomized controlled trial) including 551 patients were included. Endocardial energy sources included radiofrequency and cryoballoon. Hybrid Convergent ablation was mostly performed in patients with drug-refractory persistent and longstanding persistent AF. Mean preprocedural AF duration ranged between 2 and 5.1 years. Most patients (∼92%) underwent Hybrid Convergent in a single hospitalization. At 1 year follow-up or later, 69% (95% confidence interval [CI]: 61%-78%, n = 523) were free from atrial arrhythmias and 50% (95% CI: 42%-58%, n = 343) were free from atrial arrhythmias off antiarrhythmic drugs. Thirty-day MAE rate was 6% (95% CI: 3%-8%, n = 551). Conclusion: Hybrid Convergent ablation is an effective ablation strategy for persistent and longstanding persistent AF. Contemporary procedural approaches and published strategies aim to mitigate complications reported in early experience and address delayed inflammatory effusions.

8.
ESC Heart Fail ; 8(2): 1571-1581, 2021 04.
Artigo em Inglês | MEDLINE | ID: mdl-33619893

RESUMO

AIMS: This study aims to characterize the range of implantable device-based sensor values including heart sounds, markers of ventilation, thoracic impedance, activity, and heart rate for patients with heart failure (HF) when patients were deemed to be in clinically stable periods against the time course of acute decompensation and recovery from HF events. METHODS AND RESULTS: The MultiSENSE trial followed 900 patients implanted with a COGNIS CRT-D for up to 1 year. Chronic, ambulatory diagnostic sensor data were collected and evaluated during clinically stable periods (CSP: unchanged NYHA classification, no adverse events, and weight change ≤2.27 kg), and in the timeframe leading up to and following HF events (HF admissions or unscheduled visits with intravenous HF treatment). Physiologic sensor data from 1667 CSPs occurring in 676 patients were compared with those data leading up to and following 192 HF events in 106 patients. Overall, the mean age was 66.6 years, and the population were predominantly male (73%). Patients were primarily in NYHA II (67%), with a mean LVEF of 29.6% and median NT-proBNP of 754.5 pg/mL. Sensor values during CSP were poorer in patients who had HF events during the study period than those without HF events, including first heart sound (S1: 2.18 ± 0.84 mG vs. 2.62 ± 0.95 mG, P = 0.002), third heart sound (S3: 1.13 ± 0.36 mG vs. 0.91 ± 0.30 mG, P < 0.001), thoracic impedance (45.66 ± 8.78 Ohm vs. 50.33 ± 8.43 Ohm, P < 0.001), respiratory rate (19.09 ± 3.10 br/min vs. 17.66 ± 2.39 br/min, P = 0.002), night time heart rate (73.39 ± 8.36 b.p.m. vs. 69.56 ± 8.09 b.p.m., P = 0.001), patient activity (1.69 ± 1.84 h vs. 2.56 ± 2.20 h, P = 0.006), and HeartLogic index (11.07 ± 12.14 vs. 5.31 ± 5.13, P = 0.001). Sensor parameters measured worsening status leading up to HF events with recovery of values following treatment. CONCLUSIONS: Device-based physiologic sensors not only revealed progressive worsening leading up to HF events but also differentiated patients at increased risk of HF events when presumed to be clinically stable.


Assuntos
Insuficiência Cardíaca , Idoso , Insuficiência Cardíaca/diagnóstico , Frequência Cardíaca , Hospitalização , Humanos , Masculino
9.
Heart Rhythm ; 18(7): 1142-1150, 2021 07.
Artigo em Inglês | MEDLINE | ID: mdl-33781980

RESUMO

BACKGROUND: Cardiac device procedures require tissue dissection to free existing device lead(s). Common techniques include blunt dissection, standard electrocautery, and low-temperature electrocautery (PlasmaBlade, Medtronic); however, data on the type of electrosurgical tool used and the development of procedure- or lead-related adverse events are limited. OBJECTIVE: The purpose of this study was to determine whether standard or low-temperature electrocautery impacts the development of an adverse event. METHODS: We evaluated patients enrolled in WRAP-IT (Worldwide Randomized Antibiotic EnveloPe Infection PrevenTion Trial) undergoing cardiac implantable electronic device (CIED) revision, upgrade, or replacement. All adverse events were adjudicated by an independent physician committee. Data were analyzed using Cox proportional hazard regression modeling. RESULTS: In total, 5641 patients underwent device revision/upgrade/replacement. Electrocautery was used in 5205 patients (92.3%) (mean age 70.6 ± 12.7 years; 28.8% female), and low-temperature electrocautery was used in 1866 patients (35.9%). Compared to standard electrocautery, low-temperature electrocautery was associated with a 23% reduction in the incidence of a procedure- or lead-related adverse event through 3 years of follow up (hazard ratio [HR] 0.77; 95% confidence interval [CI] 0.65-0.91; P = .002). After controlling for the number of active leads, degree of capsulectomy, degree of lead dissection, and renal dysfunction, low-temperature electrocautery was associated with a 32% lower risk of lead-related adverse events (HR 0.68; 95% CI 0.52-0.89; P = .004). These effects were consistent across a spectrum of lead-related adverse event types. CONCLUSION: This study represents one of the largest assessments of electrocautery use in patients undergoing CIED revision, upgrade, or replacement procedures. Compared to standard electrocautery, low-temperature electrocautery significantly reduces adverse effects from these procedures.


Assuntos
Arritmias Cardíacas/terapia , Desfibriladores Implantáveis/efeitos adversos , Eletrocoagulação/métodos , Marca-Passo Artificial/efeitos adversos , Idoso , Remoção de Dispositivo , Falha de Equipamento , Feminino , Seguimentos , Humanos , Masculino , Estudos Retrospectivos , Temperatura
10.
Clin Transl Sci ; 13(3): 618-627, 2020 05.
Artigo em Inglês | MEDLINE | ID: mdl-31961467

RESUMO

Most literature describing pharmacogenetic implementations are within academic medical centers and use single-gene tests. Our objective was to describe the results and lessons learned from a multisite pharmacogenetic pilot that utilized panel-based testing in academic and nonacademic settings. This was a retrospective analysis of 667 patients from a pilot in 4 perioperative and 5 outpatient cardiology clinics. Recommendations related to 12 genes and 65 drugs were classified as actionable or not actionable. They were ascertained from Clinical Pharmacogenetics Implementation Consortium (CPIC) guidelines and US Food and Drug Administration (FDA) labeling. Patients displayed a high prevalence of actionable results (88%, 99%) and use of medications (28%, 46%) with FDA or CPIC recommendations, respectively. Sixteen percent of patients had an actionable result for a current medication per CPIC compared with 5% per FDA labeling. A systematic approach by a health system may be beneficial given the quantity and diversity of patients affected.


Assuntos
Assistência Ambulatorial/estatística & dados numéricos , Assistência Perioperatória/estatística & dados numéricos , Testes Farmacogenômicos/estatística & dados numéricos , Padrões de Prática Médica/estatística & dados numéricos , Medicina de Precisão/estatística & dados numéricos , Idoso , Assistência Ambulatorial/normas , District of Columbia , Feminino , Humanos , Masculino , Maryland , Pessoa de Meia-Idade , Assistência Perioperatória/normas , Testes Farmacogenômicos/normas , Projetos Piloto , Guias de Prática Clínica como Assunto , Padrões de Prática Médica/normas , Medicina de Precisão/métodos , Medicina de Precisão/normas , Estudos Retrospectivos , Estados Unidos , United States Food and Drug Administration/normas
11.
J Atr Fibrillation ; 12(6): 2361, 2020.
Artigo em Inglês | MEDLINE | ID: mdl-33024494

RESUMO

Pulmonary vein isolation (PVI) is the cornerstone of atrial fibrillation (AF) ablation. Yet tools and techniques used for confirmation of PVI vary greatly, and it is unclear whether the use of any particular combination of tools and techniques provides greater sensitivity for identifying gaps periprocedurally. It has been suggested the use of a high-density mapping catheter, which enables simultaneous recording of adjacent bipolar EGMs in two directions, may provide improved sensitivity for gap identification. Anonymized, acute procedural data was prospectively collected in AF ablation cases utilizing various workflows for confirmation of PVI. Post-hoc analysis was performed to evaluate the incidence of gaps detected by different diagnostic catheter technologies, including a high-density mapping catheter and circular mapping catheters (CMCs), and common techniques such as pacing the ablation lines. A total of 139 cases were included across three subgroup analyses: 99 cases were included in an indirect comparison of three mapping catheter technologies, revealing gaps in 36.7%, 38.9%, and 81.8% of cases utilizing a 10-pole CMC, 20-pole CMC, and a high-density mapping catheter, respectively; a direct comparison of diagnostic catheter technologies in 18 cryoballoon ablation cases revealed residual gaps in 22.2% of patients identified by high-density mapping which were missed previously with the use of a 3.3F CMC; in 22 cases utilizing a technique of pacing the ablation lines, high-density mapping identified residual gaps in 68.2% of patients. This proof of concept analysis demonstrated that the use of a high-density catheter which records orthogonal bipoles simultaneously, appears to improve acute detection of gaps in PVI lines relative to other commonly utilized techniques and technologies. The long-term impact of ablating these concealed gaps remains unclear. Further study, including direct comparison of diagnostic catheter technologies in a randomized setting with long-term followup, is warranted.

12.
Circ Arrhythm Electrophysiol ; 13(10): e008503, 2020 10.
Artigo em Inglês | MEDLINE | ID: mdl-32915063

RESUMO

BACKGROUND: In the WRAP-IT trial (Worldwide Randomized Antibiotic Envelope Infection Prevention), adjunctive use of an absorbable antibacterial envelope resulted in a 40% reduction of major cardiac implantable electronic device infection without increased risk of complication in 6983 patients undergoing cardiac implantable electronic device revision, replacement, upgrade, or initial cardiac resynchronization therapy defibrillator implant. There is limited information on the cost-effectiveness of this strategy. As a prespecified objective, we evaluated antibacterial envelope cost-effectiveness compared with standard-of-care infection prevention strategies in the US healthcare system. METHODS: A decision tree model was used to compare costs and outcomes of antibacterial envelope (TYRX) use adjunctive to standard-of-care infection prevention versus standard-of-care alone over a lifelong time horizon. The analysis was performed from an integrated payer-provider network perspective. Infection rates, antibacterial envelope effectiveness, infection treatment costs and patterns, infection-related mortality, and utility estimates were obtained from the WRAP-IT trial. Life expectancy and long-term costs associated with device replacement, follow-up, and healthcare utilization were sourced from the literature. Costs and quality-adjusted life years were discounted at 3%. An upper willingness-to-pay threshold of $150 000 per quality-adjusted life year was used to determine cost-effectiveness, in alignment with the American College of Cardiology/American Heart Association practice guidelines and as supported by the World Health Organization and contemporary literature. RESULTS: The base case incremental cost-effectiveness ratio of the antibacterial envelope compared with standard-of-care was $112 603/quality-adjusted life year. The incremental cost-effectiveness ratio remained lower than the willingness-to-pay threshold in 74% of iterations in the probabilistic sensitivity analysis and was most sensitive to the following model inputs: infection-related mortality, life expectancy, and infection cost. CONCLUSIONS: The absorbable antibacterial envelope was associated with a cost-effectiveness ratio below contemporary benchmarks in the WRAP-IT patient population, suggesting that the envelope provides value for the US healthcare system by reducing the incidence of cardiac implantable electronic device infection. Registration: URL: https://www.clinicaltrials.gov. Unique identifier: NCT02277990.


Assuntos
Antibacterianos/economia , Antibioticoprofilaxia/economia , Dispositivos de Terapia de Ressincronização Cardíaca/economia , Desfibriladores Implantáveis/economia , Custos de Medicamentos , Implantação de Prótese/economia , Infecções Relacionadas à Prótese/economia , Implantes Absorvíveis/economia , Antibacterianos/uso terapêutico , Dispositivos de Terapia de Ressincronização Cardíaca/efeitos adversos , Tomada de Decisão Clínica , Redução de Custos , Análise Custo-Benefício , Árvores de Decisões , Desfibriladores Implantáveis/efeitos adversos , Humanos , Modelos Econômicos , Estudos Multicêntricos como Assunto , Implantação de Prótese/efeitos adversos , Implantação de Prótese/instrumentação , Infecções Relacionadas à Prótese/microbiologia , Infecções Relacionadas à Prótese/prevenção & controle , Qualidade de Vida , Anos de Vida Ajustados por Qualidade de Vida , Ensaios Clínicos Controlados Aleatórios como Assunto , Fatores de Risco , Fatores de Tempo , Resultado do Tratamento , Estados Unidos
13.
Heart Rhythm ; 3(4): 435-42, 2006 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-16567291

RESUMO

BACKGROUND: RV pacing induces conduction delay (CD), mechanical dyssynchrony, and increased morbidity in patients with HF. CRT improves HF symptoms and survival, but sparse data exist on its direct effect on chronically RV-paced HF patients. OBJECTIVES: To assess the benefit of cardiac resynchronization therapy (CRT) in chronically right ventricle (RV)-paced heart failure (HF) patients. METHODS: We studied 12 consecutive patients with class III HF who had a previously implanted pacemaker or implantable cardioverter-defibrillator. These individuals were chronically RV paced and referred for upgrade to a biventricular device by their primary cardiologists. Tissue Doppler and strain rate imaging (TDI and SRI, respectively) were performed immediately before each upgrade and 4-6 weeks afterward to quantify changes in regional wall motion and synchrony with CRT. RESULTS: CRT significantly reduced the mean QRS duration (205 ms to 156 ms; P<.0001), and it increased the ejection fraction (30.7%+/-5.1% to 35.8%+/-5.1%; P<.01). Left ventricular end-systolic and end-diastolic dimensions were also significantly reduced. Clinically, patients improved by an average of one New York Heart Association (NYHA) functional class after upgrade (P = .006). The parameter exhibiting greatest improvement was the coefficient of variation (CoV: standard deviation/mean) of time to peak systolic strain rate, a marker of ventricular dyssynchrony, which decreased from 34.3%+/-13.0% to 19.0%+/-6.6% (P<.01). Reduction in CoV of time to peak systolic strain rate was maximally seen in the midventricle (38.2%+/-19.6% to 16.5%+/-9.7%; P<.01). CONCLUSIONS: Upgrading chronically RV-paced HF patients to CRT improves global and regional systolic function. TDI and SRI provide compelling evidence that this benefit parallels that seen in HF patients with CD unrelated to RV pacing, which implies that biventricular pacing synchronizes mechanical activation in different myocardial regions in patients upgraded from RV pacing as well.


Assuntos
Estimulação Cardíaca Artificial , Ecocardiografia , Insuficiência Cardíaca/fisiopatologia , Insuficiência Cardíaca/terapia , Idoso , Idoso de 80 Anos ou mais , Análise de Variância , Doença Crônica , Desfibriladores Implantáveis , Feminino , Sistema de Condução Cardíaco/diagnóstico por imagem , Sistema de Condução Cardíaco/fisiopatologia , Sistema de Condução Cardíaco/cirurgia , Insuficiência Cardíaca/diagnóstico por imagem , Ventrículos do Coração/diagnóstico por imagem , Ventrículos do Coração/fisiopatologia , Ventrículos do Coração/cirurgia , Humanos , Masculino , Pessoa de Meia-Idade , Insuficiência da Valva Mitral/fisiopatologia , Insuficiência da Valva Mitral/terapia , Contração Miocárdica , Marca-Passo Artificial , Índice de Gravidade de Doença , Volume Sistólico , Resultado do Tratamento , Disfunção Ventricular Esquerda/diagnóstico por imagem , Disfunção Ventricular Esquerda/cirurgia , Função Ventricular Esquerda , Remodelação Ventricular
14.
Circulation ; 110(19): 3003-10, 2004 Nov 09.
Artigo em Inglês | MEDLINE | ID: mdl-15505084

RESUMO

BACKGROUND: The purpose of this study was to determine the radiation exposure during catheter ablation of atrial fibrillation (AF) using the pulmonary vein (PV) approach. METHODS AND RESULTS: The study included 15 patients with AF and 5 patients each with atrial flutter and atrioventricular nodal reentrant tachycardia (AVNRT) who underwent fluoroscopically guided procedures on a biplane x-ray system operated at a low-frame pulsed fluoroscopy (7.5 frames per second). Radiation exposure was measured directly with 50 to 60 thermoluminescent dosimeters (TLDs). Peak skin doses (PSDs), effective radiation doses, and risk of fatal malignancies were all computed. Mean fluoroscopy durations for AF procedures were 67.8+/-21 minutes in the right anterior oblique (RAO) and 61.9+/-16.6 minutes in the left anterior oblique (LAO) projection, significantly different from that required for atrial flutter and AVNRT. The mean PSDs measured with the TLDs were 1.0+/-0.5 Gy in the RAO and 1.5+/-0.4 Gy in the LAO projection. The lifetime risk of excess fatal malignancies normalized to 60 minutes of fluoroscopy was 0.07% for women and 0.1% for men. CONCLUSIONS: The relatively small amounts of the patient's radiation exposure in this study, despite the prolonged fluoroscopy durations, can be attributed to the use of very-low-frame pulsed fluoroscopy, the avoidance of magnification, and optimal adjustments of the fluoroscopy exposure rates. The resulting lifetime risk of fatal malignancy is within the range previously reported for standard supraventricular arrhythmias.


Assuntos
Fibrilação Atrial/cirurgia , Flutter Atrial/cirurgia , Ablação por Cateter , Fluoroscopia/efeitos adversos , Veias Pulmonares/cirurgia , Radiografia Intervencionista/efeitos adversos , Dosagem Radioterapêutica , Taquicardia por Reentrada no Nó Atrioventricular/cirurgia , Adulto , Idoso , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Neoplasias Induzidas por Radiação/epidemiologia , Neoplasias Induzidas por Radiação/etiologia , Risco , Pele/efeitos da radiação , Dosimetria Termoluminescente
15.
Heart Rhythm ; 2(1): 42-8, 2005 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-15851264

RESUMO

OBJECTIVES: The purpose of this study was to report the safety, efficacy, and predictors of recurrence of circumferential pulmonary vein (PV) catheter ablation in patients with atrial fibrillation (AF). BACKGROUND: Circumferential PV ablation has been described as an alternate ablation strategy for AF. METHODS: Seventy consecutive patients (age 56 +/- 10 years) with symptomatic drug refractory paroxysmal (n = 21), persistent (n = 22), and permanent (n = 27) AF underwent catheter ablation. The catheter ablation procedure was performed by creating circular lesions encircling right- and left-side PV ostia guided by an electroanatomic (CARTO) mapping system. Linear ablation lesions also were created in the cavotricuspid isthmus, the mitral isthmus, and in the posterior left atrium. In 42 patients (60%), additions linear lesions were created between superior and inferior PVs in a "figure-of-eight" fashion. RESULTS: At 6 +/- 2.5 months of follow-up, 53 patients (76%) were AF free, including 39 patients (56%) not taking and 14 patients (20%) taking antiarrhythmic drugs. Among various variables, only early recurrence of AF was a predictor of long-term recurrence. Significant complications included one pericardial tamponade, one stroke, and two PV occlusions. Both patients with PV occlusion received radiofrequency delivery in a figure-of-eight fashion. CONCLUSIONS: Circumferential PV catheter ablation of AF is associated with moderate efficacy and risk of complications. The absence of a difference in efficacy combined with the risk of PV stenosis associated with figure-of-eight lesion lead us to conclude that the figure-of-eight lesion should not be a routine component of circumferential PV AF ablation procedures.


Assuntos
Fibrilação Atrial/cirurgia , Ablação por Cateter , Ablação por Cateter/métodos , Técnicas Eletrofisiológicas Cardíacas , Feminino , Seguimentos , Humanos , Masculino , Pessoa de Meia-Idade , Complicações Pós-Operatórias/epidemiologia , Veias Pulmonares , Recidiva , Segurança , Fatores de Tempo
16.
J Interv Card Electrophysiol ; 13(2): 107-14, 2005 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-16133837

RESUMO

INTRODUCTION: Catheter ablation to achieve pulmonary vein (PV) isolation has become an increasingly used treatment strategy for patients with atrial fibrillation (AF). The purpose of this study was to evaluate the impact of segmental isolation of PVs on volume of left atrium and its relation to the decrease in the size of the pulmonary veins. METHODS: Gadolinium enhanced Magnetic Resonance Angiography (MRA) was performed in 51 AF patients before and 6 approximately 8 weeks post PV isolation, using cooled radio-frequency (RF) energy. Three-dimensional reconstruction with maximum intensity projections and multiplanar reformations was performed. Oblique coronal projections were used to measure the ostial size of PVs. Three orthogonal dimensions of LA chamber were measured and computed to assess the volume of the left atrium. RESULTS: The mean LA volume decreased by 15.7% after ablation (p<0.001). The mean PV ostial diameter decreased by 11%, from 18.3+/-0.8 mm to 16.7+/-1.0 mm (p=0.005). Moderate PV stenosis was noted in two veins out of the 192 veins analyzed. There was a significant correlation between changes in the size of PV ostium to that of the LA. CONCLUSIONS: Catheter ablation of AF using a segmental PV isolation approach results in a significant reverse remodeling in the left atrium. Significant stenosis of PVs appears to be rare after the segmental isolation procedure.


Assuntos
Fibrilação Atrial/cirurgia , Ablação por Cateter , Angiografia por Ressonância Magnética , Veias Pulmonares/patologia , Pneumopatia Veno-Oclusiva/diagnóstico , Técnicas Eletrofisiológicas Cardíacas , Feminino , Humanos , Processamento de Imagem Assistida por Computador , Imageamento Tridimensional , Modelos Lineares , Masculino , Pessoa de Meia-Idade , Variações Dependentes do Observador , Veias Pulmonares/cirurgia , Resultado do Tratamento
17.
Heart Rhythm ; 12(2): 360-6, 2015 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-25446153

RESUMO

BACKGROUND: Implantable cardioverter-defibrillator (ICD) implantation is contraindicated in those with <1-year life expectancy. OBJECTIVES: The aim of this study was to develop a risk prediction score for 1-year mortality in patients with primary prevention ICDs and to determine the incremental improvement in discrimination when serum-based biomarkers are added to traditional clinical variables. METHODS: We analyzed data from the Prospective Observational Study of Implantable Cardioverter-Defibrillators, a large prospective observational study of patients undergoing primary prevention ICD implantation who were extensively phenotyped for clinical and serum-based biomarkers. We identified variables predicting 1-year mortality and synthesized them into a comprehensive risk scoring construct using backward selection. RESULTS: Of 1189 patients deemed by their treating physicians as having a reasonable 1-year life expectancy, 62 (5.2%) patients died within 1 year of ICD implantation. The risk score, composed of 6 clinical factors (age ≥75 years, New York Heart Association class III/IV, atrial fibrillation, estimated glomerular filtration rate <30 mL/min/1.73 m(2), diabetes, and use of diuretics), had good discrimination (area under the curve 0.77) for 1-year mortality. Addition of 3 biomarkers (tumor necrosis factor α receptor II, pro-brain natriuretic peptide, and cardiac troponin T) further improved model discrimination to 0.82. Patients with 0-1, 2-3, 4-6, or 7-9 risk factors had 1-year mortality rates of 0.8%, 2.7%, 16.1%, and 46.2%, respectively. CONCLUSION: Individuals with more comorbidities and elevation of specific serum biomarkers were at increased risk of all-cause mortality despite being deemed as having a reasonable 1-year life expectancy. A simple risk score composed of readily available clinical data and serum biomarkers may better identify patients at high risk of early mortality and improve patient selection and counseling for primary prevention ICD therapy.


Assuntos
Biomarcadores/sangue , Morte Súbita Cardíaca/prevenção & controle , Desfibriladores Implantáveis , Insuficiência Cardíaca/sangue , Prevenção Primária/métodos , Medição de Risco , Idoso , Creatina Quinase Forma MB/sangue , Morte Súbita Cardíaca/epidemiologia , Feminino , Insuficiência Cardíaca/mortalidade , Insuficiência Cardíaca/terapia , Humanos , Incidência , Masculino , Pessoa de Meia-Idade , Peptídeo Natriurético Encefálico/sangue , Países Baixos/epidemiologia , Fragmentos de Peptídeos/sangue , Prognóstico , Estudos Prospectivos , Precursores de Proteínas , Fatores de Risco , Taxa de Sobrevida/tendências , Troponina T/sangue , Estados Unidos/epidemiologia
18.
J Am Coll Cardiol ; 66(5): 524-31, 2015 Aug 04.
Artigo em Inglês | MEDLINE | ID: mdl-26227190

RESUMO

BACKGROUND: Heart failure patients with primary prevention implantable cardioverter-defibrillators (ICD) may experience an improvement in left ventricular ejection fraction (LVEF) over time. However, it is unclear how LVEF improvement affects subsequent risk for mortality and sudden cardiac death. OBJECTIVES: This study sought to assess changes in LVEF after ICD implantation and the implication of these changes on subsequent mortality and ICD shocks. METHODS: We conducted a prospective cohort study of 538 patients with repeated LVEF assessments after ICD implantation for primary prevention of sudden cardiac death. The primary endpoint was appropriate ICD shock defined as a shock for ventricular tachyarrhythmias. The secondary endpoint was all-cause mortality. RESULTS: Over a mean follow-up of 4.9 years, LVEF decreased in 13.0%, improved in 40.0%, and was unchanged in 47.0% of the patients. In the multivariate Cox models comparing patients with an improved LVEF with those with an unchanged LVEF, the hazard ratios were 0.33 (95% confidence interval: 0.18 to 0.59) for mortality and 0.29 (95% confidence interval: 0.11 to 0.78) for appropriate shock. During follow-up, 25% of patients showed an improvement in LVEF to >35% and their risk of appropriate shock decreased but was not eliminated. CONCLUSIONS: Among primary prevention ICD patients, 40.0% had an improved LVEF during follow-up and 25% had LVEF improved to >35%. Changes in LVEF were inversely associated with all-cause mortality and appropriate shocks for ventricular tachyarrhythmias. In patients whose follow-up LVEF improved to >35%, the risk of an appropriate shock remained but was markedly decreased.


Assuntos
Terapia de Ressincronização Cardíaca , Morte Súbita Cardíaca , Cardioversão Elétrica , Insuficiência Cardíaca , Disfunção Ventricular Esquerda , Idoso , Terapia de Ressincronização Cardíaca/métodos , Terapia de Ressincronização Cardíaca/estatística & dados numéricos , Estudos de Coortes , Morte Súbita Cardíaca/epidemiologia , Morte Súbita Cardíaca/etiologia , Morte Súbita Cardíaca/prevenção & controle , Desfibriladores Implantáveis , Cardioversão Elétrica/instrumentação , Cardioversão Elétrica/métodos , Feminino , Insuficiência Cardíaca/complicações , Insuficiência Cardíaca/terapia , Humanos , Incidência , Masculino , Pessoa de Meia-Idade , Modelos de Riscos Proporcionais , Estudos Prospectivos , Medição de Risco , Índice de Gravidade de Doença , Volume Sistólico , Estados Unidos/epidemiologia , Disfunção Ventricular Esquerda/diagnóstico , Disfunção Ventricular Esquerda/etiologia , Disfunção Ventricular Esquerda/mortalidade
19.
Circ Arrhythm Electrophysiol ; 7(6): 1084-91, 2014 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-25273351

RESUMO

BACKGROUND: Primary prevention implantable cardioverter defibrillators (ICDs) reduce all-cause mortality, but the benefits are heterogeneous. Current risk stratification based on left ventricular ejection fraction has limited discrimination power. We hypothesize that biomarkers for inflammation, neurohumoral activation, and cardiac injury can predict appropriate shocks and all-cause mortality in patients with primary prevention ICDs. METHODS AND RESULTS: The Prospective Observational Study of Implantable Cardioverter Defibrillators (PROSe-ICD) enrolled 1189 patients with systolic heart failure who underwent ICD implantation for primary prevention of sudden cardiac death. The primary end point was an ICD shock for adjudicated ventricular tachyarrhythmia. The secondary end point was all-cause mortality. After a median follow-up of 4.0 years, 137 subjects experienced an appropriate ICD shock and 343 participants died (incidence rates of 3.2 and 5.8 per 100 person-years, respectively). In multivariable-adjusted models, higher interleukin-6 levels increased the risk of appropriate ICD shocks. In contrast, C-reactive protein, interleukin-6, tumor necrosis factor-α receptor II, pro-brain natriuretic peptide (pro-BNP), and cardiac troponin T showed significant linear trends for increased risk of all-cause mortality across quartiles. A score combining these 5 biomarkers identified patients who were much more likely to die than to receive an appropriate shock from the ICD. CONCLUSIONS: An increase in serum biomarkers of inflammation, neurohumoral activation, and myocardial injury increased the risk for death but poorly predicted the likelihood of an ICD shock. These findings highlight the potential importance of serum-based biomarkers in identifying patients who are unlikely to benefit from primary prevention ICDs. CLINICAL TRIAL REGISTRATION URL: clinicaltrials.gov; Unique Identifier: NCT00733590.


Assuntos
Proteínas Sanguíneas/análise , Morte Súbita Cardíaca/prevenção & controle , Desfibriladores Implantáveis , Cardioversão Elétrica/instrumentação , Prevenção Primária/instrumentação , Idoso , Biomarcadores/sangue , Distribuição de Qui-Quadrado , Morte Súbita Cardíaca/etiologia , Feminino , Humanos , Mediadores da Inflamação/sangue , Modelos Lineares , Masculino , Pessoa de Meia-Idade , Análise Multivariada , Miocárdio/metabolismo , Peptídeo Natriurético Encefálico/sangue , Seleção de Pacientes , Valor Preditivo dos Testes , Prevenção Primária/métodos , Modelos de Riscos Proporcionais , Estudos Prospectivos , Precursores de Proteínas/sangue , Medição de Risco , Fatores de Risco , Estados Unidos/epidemiologia
20.
Heart Rhythm ; 11(8): 1377-83, 2014 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-24793459

RESUMO

BACKGROUND: Implantable cardioverter-defibrillators (ICDs) reduce the risk of death in patients with left ventricular dysfunction. Little is known regarding the benefit of this therapy in African Americans (AAs). OBJECTIVE: The purpose of this study was to determine the association between AA race and outcomes in a cohort of primary prevention ICD patients. METHODS: We conducted a prospective cohort study of patients with systolic heart failure who underwent ICD implantation for primary prevention of sudden cardiac death. The primary end-point was appropriate ICD shock defined as a shock for rapid ventricular tachyarrhythmias. The secondary end-point was all-cause mortality. RESULTS: There were 1189 patients (447 AAs and 712 non-AAs) enrolled. Over a median follow-up of 5.1 years, a total of 137 patients experienced an appropriate ICD shock, and 343 died (294 of whom died without receiving an appropriate ICD shock). The multivariate adjusted hazard ratio (95% confidence interval) comparing AAs vs non-AAs were 1.24 (0.96-1.59) for all-cause mortality, 1.33 (1.02, 1.74) for all-cause mortality without receiving appropriate ICD shock, and 0.78 (0.51, 1.19) for appropriate ICD shock. Ejection fraction, diabetes, and hypertension appeared to explain 24.1% (10.1%-69.5%), 18.7% (5.3%-58.0%), and 13.6% (3.8%-53.6%) of the excess risk of mortality in AAs, with a large proportion of the mortality difference remaining unexplained. CONCLUSION: In patients with primary prevention ICDs, AAs had an increased risk of dying without receiving an appropriate ICD shock compared to non-AAs.


Assuntos
Negro ou Afro-Americano , Morte Súbita Cardíaca/prevenção & controle , Desfibriladores Implantáveis , Prevenção Primária/métodos , Medição de Risco , Disfunção Ventricular Esquerda/terapia , Morte Súbita Cardíaca/epidemiologia , Feminino , Seguimentos , Humanos , Incidência , Masculino , Pessoa de Meia-Idade , Prognóstico , Estudos Prospectivos , Fatores de Risco , Estados Unidos/epidemiologia , Disfunção Ventricular Esquerda/etnologia , Disfunção Ventricular Esquerda/fisiopatologia
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA