Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 10 de 10
Filtrar
1.
Pacing Clin Electrophysiol ; 44(7): 1176-1184, 2021 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-34028066

RESUMO

INTRODUCTION: There is limited data using continuous monitoring to assess outcomes of atrial fibrillation (AF) ablation. This study assessed long-term outcomes of AF ablation in patients with implantable cardiac devices. METHODS: 207 patients (mean age 68.1 ± 9.5, 50.3% men) undergoing ablation for symptomatic AF were followed up for a mean period of 924.5 ± 636.7 days. Techniques included The Pulmonary Vein Ablation Catheter (PVAC) (59.4%), cryoablation (17.4%), point by point (14.0%) and The Novel Irrigated Multipolar Radiofrequency Ablation Catheter (nMARQ) (9.2%). RESULTS: 130 (62.8%) patients had paroxysmal AF (PAF) and 77 (37.2%) persistent AF. First ablation and repeat ablation reduced AF burden significantly (relative risk 0.91, [95% CI 0.89 to 0.94]; P <0.0001 and 0.90, [95% CI, 0.86-0.94]; P <0.0001). Median AF burden in PAF patients reduced from 1.05% (interquartile range [IQR], 0.1%-8.70%) to 0.10% ([IQR], 0%-2.28%) at one year and this was maintained out to four-years. Persistent AF burden reduced from 99.9% ([IQR], 51.53%-100%) to 0.30% ([IQR], 0%-77.25%) at one year increasing to 87.3% ([IQR], 4.25%-100%) after four years. If a second ablation was required, point-by-point ablation achieved greater reduction in AF burden (relative risk, 0.77 [95% CI, 0.65-0.91]; P <0.01). CONCLUSION: Ablation reduces AF burden both acutely and in the long-term. If a second ablation was required the point-by-point technique achieved greater reductions in AF burden than "single-shot" technologies. Persistent AF burden increased to near pre ablation levels by year 4 suggesting a different mechanism from PAF patients where this increase did not occur.


Assuntos
Fibrilação Atrial/cirurgia , Ablação por Cateter , Idoso , Estudos de Coortes , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Fatores de Tempo , Resultado do Tratamento
2.
Am Heart J ; 207: 86-87, 2019 01.
Artigo em Inglês | MEDLINE | ID: mdl-30414626

RESUMO

A central iliac arteriovenous anastomosis, the 'coupler' (ROX Medical, California, USA) results in a significant reduction in blood pressure in hypertensive patients. This study assessed the change in AF burden following coupler implantation in patients with paroxysmal AF (PAF) and hypertension. Good blood pressure control using the coupler results in a significant reduction in AF burden.


Assuntos
Derivação Arteriovenosa Cirúrgica/métodos , Fibrilação Atrial/cirurgia , Hipertensão/cirurgia , Idoso , Idoso de 80 Anos ou mais , Fibrilação Atrial/diagnóstico , Feminino , Humanos , Hipertensão/diagnóstico , Artéria Ilíaca , Veia Ilíaca , Masculino , Pessoa de Meia-Idade , Fatores de Tempo
3.
Int J Clin Pract ; : e13410, 2019 Aug 29.
Artigo em Inglês | MEDLINE | ID: mdl-31464020

RESUMO

OBJECTIVE: To investigate the accuracy of three non-invasive blood pressure (BP) devices in atrial fibrillation (AF) compared with invasive arterial BP. METHODS: One hundred patients aged 45-90 years, 63% male (50 in AF and 50 age matched controls in sinus rhythm [SR]) were identified with arterial lines measuring beat-to-beat BP fluctuation. Non-invasive BP measurements utilising the manual sphygmomanometer (MS), PulseCor R6.5 (PC) and automated sphygmomanometer (AS) were taken simultaneously with invasive BP in a randomised sequence. This was repeated three times in each patient. RESULTS: In SR differences in systolic BP (SBP) for MS, AS and PC were -0.34 mm Hg (95% CI -2.31 to 1.63; P = .733), -3.80 mm Hg (95% CI -5.73 to -1.87; P = .0001) and -3.90 mm Hg (95% CI -5.90 to -1.90; P = .0001) and for diastolic BP (DBP) were 6.02 mm Hg (95% CI 4.39-7.64; P < .0001), 8.95 mm Hg (95% CI 7.36-10.55; P < .0001) and 7.54 mm Hg (95% CI 5.89-9.18; P < .0001), respectively. In AF mean differences in SBP for MS, AS and PC were -7.33 mm Hg (95% CI -9.11 to -5.55; P < .0001), -5.29 mm Hg (95% CI -7.08 to -3.50; P < .0001) and -5.75 mm Hg (95% CI -7.54 to -3.96; P < .0001) respectively and for DBP were 5.28 mm Hg (95% CI 4.03-6.54; P < .0001), 6.26 mm Hg (95% CI 5.00-7.52; P < .0001) and 6.89 mm Hg (95% CI 5.64-8.15; P < .0001) respectively. CONCLUSIONS: The MS is accurate in SR because of direct assessment of Korotkoff sounds. Non-invasive BP assessment in AF is significantly less accurate. These findings have important prognostic and therapeutic implications.

4.
Eur Heart J Case Rep ; 7(1): ytac474, 2023 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-36685101

RESUMO

Background: Leadless pacemakers present a viable alternative to conventional transvenous devices to mitigate the risk of lead- and/or pocket-related complications. In elderly patients who have encountered ventricular lead failures with transvenous pacemakers, this option may enable the delivery of atrioventricular synchronous pacing therapy, while obviating the requirement for lead extraction and lead-based pacemaker re-implantation. Case summary: This case report describes the successful implantation of a leadless pacemaker in a 90-year-old who had undergone two dual-chamber permanent pacemaker implantation procedures with a failure of three of four previously implanted leads. Atrioventricular synchronous pacing was achieved, as the leadless device was able to track the atrial-paced rhythm from the pre-existing right-sided device. Discussion: In elderly patients who have encountered issues with transvenous pacemakers, alternative approaches should be considered to mitigate the risk of future complications. Leadless pacemakers may offer a low-risk solution, enabling the delivery of atrioventricular synchronous pacing therapy in such patient groups. Future studies should be designed to delineate whether these devices could be utilized as a first-line approach in certain situations.

5.
JACC Case Rep ; 4(18): 1213-1217, 2022 Sep 21.
Artigo em Inglês | MEDLINE | ID: mdl-36213881

RESUMO

We present the case of an 81-year-old woman with a background of situs inversus with dextrocardia who was successfully treated for tachycardia-bradycardia syndrome with left bundle area pacing. This report describes how this approach can circumvent the limitations of other pacing approaches to optimize patient outcomes. (Level of Difficulty: Intermediate.).

6.
Arrhythm Electrophysiol Rev ; 9(3): 161-166, 2020 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-33240512

RESUMO

AF and heart failure (HF) commonly coexist. Left atrial ablation is an effective treatment to maintain sinus rhythm (SR) in patients with AF. Recent evidence suggests that the use of ablation for AF in patients with HF is associated with an improved left ventricular ejection fraction and lower death and HF hospitalisation rates. We performed a systematic search of world literature to analyse the association in more detail and to assess the utility of AF ablation as a non-pharmacological tool in the treatment of patients with concomitant HF.

7.
J Clin Hypertens (Greenwich) ; 21(9): 1399-1405, 2019 09.
Artigo em Inglês | MEDLINE | ID: mdl-31347773

RESUMO

A central iliac arteriovenous anastomosis, termed the "coupler" (ROX Medical), results in a significant reduction in blood pressure (BP) in hypertensive patients. This study assessed functional and hemodynamic changes induced by the device. Twenty-one patients with resistant and/or uncontrolled hypertension underwent stress echocardiography and cardiopulmonary exercise testing (CPET) at baseline and 6 months post-coupler implantation. End points were selected to best evaluate cardiac function including Doppler stroke volume (SV), septal and lateral E/E', and right ventricular systolic velocity S' (RV S'). CPET VO2 peak demonstrated total cardiopulmonary performance. SV increased from 76.4 SD12.2 mL to 92.1 SD22.7 mL 6 months post-coupler insertion; P = .002. No changes in RV S', septal or lateral E/E', or VO2 peak were observed. Five patients experienced increased diuretic requirement ≥3 times baseline. RV S' fell from 19.0 SD1.87 cm/s to 16.80 SD3.43 cm/s in these patients (P > .05). A significant increase in SV 6 months post-coupler insertion was observed. In patients with increased diuretic requirement, the device was associated with a lower RV S' suggesting occult RV dysfunction as the mechanism of this pre-specified adverse outcome.


Assuntos
Derivação Arteriovenosa Cirúrgica/instrumentação , Vasoespasmo Coronário/fisiopatologia , Hemodinâmica/fisiologia , Hipertensão/fisiopatologia , Função Ventricular Direita/fisiologia , Idoso , Idoso de 80 Anos ou mais , Anastomose Arteriovenosa , Derivação Arteriovenosa Cirúrgica/efeitos adversos , Pressão Sanguínea/fisiologia , Determinação da Pressão Arterial/métodos , Vasoespasmo Coronário/cirurgia , Ecocardiografia/métodos , Ecocardiografia sob Estresse/métodos , Teste de Esforço/métodos , Feminino , Humanos , Hipertensão/cirurgia , Artéria Ilíaca/cirurgia , Veia Ilíaca/cirurgia , Masculino , Pessoa de Meia-Idade , Estudos Prospectivos , Segurança , Volume Sistólico/fisiologia , Sístole/fisiologia
8.
Clin Respir J ; 13(5): 280-288, 2019 May.
Artigo em Inglês | MEDLINE | ID: mdl-30793493

RESUMO

BACKGROUND: Sleep-disordered breathing (SDB) and atrial fibrillation (AF) are associated. This study investigated the impact of AF intervention on 6-month home sleep testing data. METHODS: Sixty-seven patients (aged 66 to 86, 53% male) with persistent AF were randomized (1:1:1) to direct current cardioversion (DCCV) (22 patients), permanent pacemaker (PPM) + atrioventricular node ablation (AVNA) + DCCV (22 patients) or AF ablation (23 patients). Baseline and 6-month multichannel home sleep tests with the Watch-PAT200 (Itamar Medical Lts., Caesarea, Israel) were recorded. Implantable cardiac monitors (ICMs) (Medtronic Reveal XT, Minneapolis, Minnesota) in the DCCV and AF ablation groups, and PPM Holters in the 'pace and ablate' group were utilized to assess cardiac rhythm beat-to-beat throughout the study period. RESULTS: The prevalence of moderate-to-severe SDB [apnoea-hypopnoea index (AHI) ≥ 15/h] was 60%. At 6 months there was no change in AHI, Epworth sleepiness scale, sleep time, % REM sleep, respiratory desaturation index or central apnoeic events. Twenty-five patients (15 AF ablation, 9 DCCV and 1 following DCCV post-AVNA) maintained SR at 6 months confirmed on ICMs in these patients. AHI fell from 29.8 ± 26.6/h to 22.2 ± 20.4/h; P = 0.049. CONCLUSIONS: SDB is highly prevalent in patients with persistent AF. Restoration of sinus rhythm, and the associated long-term recovery of haemodynamics, is associated with a significant reduction in AHI. This implicates reversal of fluid shift from the lower limbs to the neck region, a key mechanism in the pathogenesis of SDB.


Assuntos
Fibrilação Atrial/complicações , Fibrilação Atrial/terapia , Síndromes da Apneia do Sono/complicações , Síndromes da Apneia do Sono/prevenção & controle , Idoso , Idoso de 80 Anos ou mais , Ablação por Cateter , Cardioversão Elétrica , Eletrocardiografia Ambulatorial , Feminino , Humanos , Masculino , Marca-Passo Artificial , Polissonografia , Prevalência , Síndromes da Apneia do Sono/epidemiologia
9.
BMJ Case Rep ; 20162016 Jan 20.
Artigo em Inglês | MEDLINE | ID: mdl-26791131

RESUMO

The ROX Coupler is a device that allows creation of a central arteriovenous anastomosis at the iliac level. The device has been shown to improve exercise capacity in patients with chronic obstructive pulmonary disease and is CE marked for the treatment of resistant and uncontrolled hypertension. Reflex syncope is a challenging clinical condition with limited proven therapeutic options. We describe the resolution of symptoms and tilt table response of a patient who underwent insertion of a ROX Coupler to treat hypertension, and also incidentally had pre-existing vasodepressor syncope.


Assuntos
Hipertensão/cirurgia , Síncope Vasovagal/diagnóstico , Síncope Vasovagal/cirurgia , Idoso , Anastomose Arteriovenosa/cirurgia , Feminino , Humanos , Hipertensão/fisiopatologia , Reflexo , Síncope Vasovagal/fisiopatologia , Teste da Mesa Inclinada/métodos , Resultado do Tratamento
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA