Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Mais filtros

Base de dados
Ano de publicação
Tipo de documento
País de afiliação
Intervalo de ano de publicação
1.
Circ J ; 83(12): 2443-2451, 2019 11 25.
Artigo em Inglês | MEDLINE | ID: mdl-31708555

RESUMO

BACKGROUND: Radiofrequency (RF)-based pulmonary vein isolation (PVI) results in a favorable clinical outcome, although its complexity demands a long learning curve. Balloon-based systems have been developed to possibly solve these limitations. The 2nd-generation laser balloon (LB2) offers optimized features for improved tissue contact and visibility. We determined the safety, efficacy and learning curve of the LB2 for PVI.Methods and Results:A total of 45 consecutive patients (89% persistent AF) were prospectively enrolled and divided into 3 groups (T1, T2, T3) of n=15 patients per group. All patients underwent PVI by 2 operators using the LB2. The operators were experienced in RF and cryothermal procedures, but not in laser ablations. A total of 174/177 PVs (98%) were successfully isolated. The median procedure time significantly declined from 132 (114, 158) to 119 (102, 127) and 91 (86, 105) min in T1-3, respectively (P=0.0009). Similarly, the median fluoroscopy time significantly decreased from T1 to T3 (22 (17, 27) vs. 21 (16, 24) vs. 13 (10, 17) min, respectively, P=0.045). Adverse events occurred in 6.7%, with a trend towards a lower complication rate with increasing experience. CONCLUSIONS: The LB2 was safe and effective for PVI, even for operators without any previous experience in laser balloon-based PVI. Procedure time, left atrial dwelling time and fluoroscopy time decreased after a learning curve of 15 cases.


Assuntos
Fibrilação Atrial/cirurgia , Cateteres Cardíacos , Ablação por Cateter/instrumentação , Competência Clínica , Terapia a Laser/instrumentação , Curva de Aprendizado , Veias Pulmonares/cirurgia , Potenciais de Ação , Idoso , Fibrilação Atrial/diagnóstico , Fibrilação Atrial/fisiopatologia , Ablação por Cateter/efeitos adversos , Desenho de Equipamento , Feminino , Frequência Cardíaca , Humanos , Terapia a Laser/efeitos adversos , Masculino , Pessoa de Meia-Idade , Segurança do Paciente , Estudos Prospectivos , Veias Pulmonares/fisiopatologia , Sistema de Registros , Medição de Risco , Fatores de Risco , Fatores de Tempo , Resultado do Tratamento
2.
Int J Cardiol Heart Vasc ; 29: 100576, 2020 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-32642555

RESUMO

BACKGROUND: Balloon-based ablation systems for pulmonary vein isolation (PVI) are providing procedural safety and efficacy as well as favourable clinical outcome. Although second-generation laser balloon (LB2) based PVI has been shown safety and efficacy relatively long procedural duration was a strong limitation. The third-generation laser balloon (LB3) offers and automized ablation for rapid PVI. We determined safety, efficacy and procedural characteristics of this new promising ablation system. METHODS AND RESULTS: A total of 15 consecutive patients were prospectively enrolled. All patients underwent PVI using the LB3. A total 59/59 PVs (100%) were successfully isolated. Procedural data was compared to the last 15 consecutive patients treated by the LB2. The median procedure time significantly declined from LB2 (91 (86, 105) min) to LB3 (77 (68, 87) min), p < 0.001. Similarly, the median left atrial dwelling time significantly decreased from LB2 (72 (62, 84) min) to LB3 (45 (38, 52) min), p < 0.0001. The total laser time decreased from LB2 (1920 (1765, 2193) sec) to LB3 (1077 (896, 1165) sec), p < 0.00001. A pure single shot PVI was performed in 18/59 PVs (31%). For major adverse events no differences were detected between the groups (LB2 1/15 (6.7%) and LB3 1/15 (6.7%), p = 0.999). CONCLUSION: The LB3 was safe and effective for PVI. Procedure time, LA dwelling time and total laser time significantly decreased compared to LB2.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA