Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 19 de 19
Filtrar
Mais filtros

País/Região como assunto
País de afiliação
Intervalo de ano de publicação
1.
Mem Inst Oswaldo Cruz ; 114: e180529, 2019.
Artigo em Inglês | MEDLINE | ID: mdl-31166420

RESUMO

Helmintex is a sensitive method used for detecting Schistosoma mansoni eggs. Here, we describe the observed frequency of six proposed criteria associated with the identification of S. mansoni eggs prepared with the Helmintex method and stained with ninhydrin. The efficacy of these criteria in classifying S. mansoni eggs when applied in various combinations was also examined. Nine observers registered the presence or absence of 6 different criteria in 100 eggs using a microscope at 100x magnification. Ninhydrin purple, which was frequently observed, was the criterion associated with the lowest inter-observer variability. At least three criteria were associated with a significantly better performance in egg identification. In conclusion, ninhydrin staining and a combination of criteria are recommended for microscope examination of faecal sediments.


Assuntos
Fezes/parasitologia , Indicadores e Reagentes , Ninidrina , Óvulo/citologia , Contagem de Ovos de Parasitas/métodos , Schistosoma mansoni/isolamento & purificação , Animais , Contagem de Ovos de Parasitas/normas , Valores de Referência , Reprodutibilidade dos Testes
2.
Exp Parasitol ; 177: 28-34, 2017 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-28431921

RESUMO

A diagnostic test that is reliable, sensitive, and applicable in the field is extremely important in epidemiological surveys, during medical treatment for schistosomiasis, and for the control and elimination of schistosomiasis. The Helmintex (HTX) method is based on the use of magnetic beads to trap eggs in a magnetic field. This technique is highly sensitive, but the screening of fecal samples consumes lots of time, thus delaying the results, especially in field studies. The objective of this work was to determine the effects of incorporation of the detergent Tween-20 into the method in an attempt to decrease the final pellet volume produced by the HTX method as well as the use of ninhydrin to stain the Schistosoma mansoni eggs. We showed that these modifications reduced the final volume of the fecal sediment produced in the last step of the HTX method by up to 69% and decreased the screening time to an average of 10.1 min per sample. The use of Tween 20 and ninhydrin led to a high percentage of egg recovery (27.2%). The data obtained herein demonstrate that the addition of detergent and the use of ninhydrin to the HTX process can optimize the screening step and also improve egg recovery, thus justifying the insertion of these steps into the HTX method.


Assuntos
Fezes/parasitologia , Schistosoma mansoni/isolamento & purificação , Esquistossomose mansoni/diagnóstico , Animais , Celulase/metabolismo , Humanos , Indicadores e Reagentes , Campos Magnéticos , Camundongos , Ninidrina , Óvulo , Contagem de Ovos de Parasitas/métodos , Polissorbatos , Tensoativos , Fatores de Tempo , Fixação de Tecidos/métodos
3.
Acta Trop ; 248: 107017, 2023 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-37774894

RESUMO

Intestinal schistosomiasis is a chronic and debilitating disease that affects public health systems worldwide. Control interventions to reduce morbidity primarily involve the diagnosis and treatment of infected individuals. However, the recommended Kato-Katz (KK) parasitological method shows low sensitivity in individuals with low parasite loads and is not useful for monitoring elimination of parasite transmission at later stages. In the current study, we evaluated the accuracy of serum reactivity levels of different immunoglobulin isotypes in an enzyme-linked immunosorbent assay (ELISA), utilizing Schistosoma mansoni crude extracts, with the aim to improve the diagnosis of infected individuals with low parasite loads. The serum reactivity of IgM and IgG subclass antibodies (IgG1, IgG3, and IgG4) against soluble adult worm and egg antigen preparations was evaluated in residents from a schistosomiasis-endemic area in northern Minas Gerais, Brazil. The parasitological status of the study population was determined through fecal examination with multiple parasitological tests to create a consolidated reference standard (CRS) plus a fecal DNA detection test (q-PCR). Twelve months after praziquantel treatment, a second serum sample was obtained from the population for reexamination. A two-graph receiver operating characteristic curve (TG-ROC) analysis was performed using the serum reactivity of non-infected endemic controls and egg-positive individuals, and the cut-off value was established based on the intersection point of the sensibility and specificity curves in TG-ROC analyses. The diagnostic accuracy of each serological test was evaluated in relation to the parasitological CRS and to the combination of CRS plus qPCR results. The data revealed that serum reactivity of IgM and IgG3 against S. mansoni antigens did not allow identification of infected individuals from the endemic area. In contrast, serum IgG1 and IgG4-reactivity against schistosome antigens could distinguish between infected and non-infected individuals, with AUC values ranging between 0.728-0.925. The reactivity of IgG4 anti-soluble egg antigen - SEA (sensitivity 79 %, specificity 69 %, kappa = 0.49) had the best diagnostic accuracy, showing positive reactivity in more than 75 % of the infected individuals who eliminated less than 12 eggs per gram of feces. Moreover, serum IgG4 reactivity against SEA and against soluble worm antigen preparation (SWAP) was significantly reduced in the serum of infected individuals after 12 months of confirmed parasitological cure and in the absence of re-infection. These results reinforce that the described IgG4 anti-SEA ELISA assay is a sensitive alternative for the diagnosis of active intestinal schistosomiasis in individuals from endemic areas, including in those with a very low parasite load.


Assuntos
Parasitos , Esquistossomose mansoni , Adulto , Animais , Humanos , Esquistossomose mansoni/diagnóstico , Esquistossomose mansoni/tratamento farmacológico , Esquistossomose mansoni/epidemiologia , Antígenos de Helmintos , Schistosoma mansoni , Imunoglobulina G , Ensaio de Imunoadsorção Enzimática , Sensibilidade e Especificidade , Anticorpos Anti-Helmínticos , Imunoglobulina M , Fezes/parasitologia
4.
Artigo em Inglês | MEDLINE | ID: mdl-36700600

RESUMO

BACKGROUND: The World Health Organization recommends a market-ready, urine-based point-of-care diagnostic test for circulating cathodic antigens (CCA) to determine the prevalence of S. mansoni. This study evaluated the performance of the URINE CCA (SCHISTO) ECO TESTE® (POC-ECO), which is currently available in Brazil. METHODS: Residents from eight sites with different prevalence estimates provided one urine sample for POC-ECO and one stool sample for Kato-Katz (KK) and Helmintex® (HTX) testing as an egg-detecting reference for infection status. RESULTS: None of the study sites had significantly higher POC-ECO accuracy than KK. CONCLUSIONS: POC-ECO is not currently recommended in Brazilian schistosomiasis elimination programs.


Assuntos
Esquistossomose mansoni , Animais , Humanos , Esquistossomose mansoni/diagnóstico , Esquistossomose mansoni/epidemiologia , Schistosoma mansoni , Brasil/epidemiologia , Sistemas Automatizados de Assistência Junto ao Leito , Sensibilidade e Especificidade , Antígenos de Helmintos/urina , Prevalência , Fezes
5.
Acta Trop ; 215: 105800, 2021 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-33352167

RESUMO

Many antigens for use in antibody-detection systems for schistosomiasis have been investigated over the past 40 years. In particular, soluble egg antigens (SEA) are still widely used in enzyme-linked immunosorbent assays (ELISAs) for detection of immunoglobulin classes and subclasses. Here, we conducted a literature review to examine accuracy evaluations of SEA-Immunoglobulin G (IgG)-ELISAs performed to detect Schistosoma mansoni infections and published between 1979 and 2019. S. mansoni is the main causative agent for intestinal schistosomiasis in many countries in Africa and Central and South America. After retrieving 214 relevant abstracts from the PubMed database, we selected 15 publications to undergo a full review. Sensitivity and specificity values varied from 71 to 99%, and from 6 to 100%, respectively. In addition, 11/15 studies did not state confidence intervals. Therefore, the findings from this review indicate that after four decades, we still do not have consistent evaluation estimates of SEA-IgG-ELISAs. Antigen mass per well and dilution of test sera in these articles varied from 0.018 µg to 1.5 µg, and from 1:50 to 1:500, respectively. Most of the reported accuracy evaluations used control sera which were selected based on parasitological examinations for egg detection, although ill-defined criteria were also noted. The number and composition of control serum panels was considered not adequate in approximately half of the studies. It is also noteworthy that among more than 30 diagnostic antigen preparations under development since the 1970s, most were not validated in the field and they failed to reach populations in need. Thus, attention to guidelines for standardization, estimations of accuracy, and reporting of results is needed to facilitate coordinated efforts aimed at schistosomiasis control and elimination.


Assuntos
Anticorpos Anti-Helmínticos/sangue , Antígenos de Helmintos/imunologia , Schistosoma mansoni/imunologia , Esquistossomose mansoni/diagnóstico , Animais , Ensaio de Imunoadsorção Enzimática , Humanos , Imunoglobulina G/sangue , Óvulo/imunologia , Esquistossomose mansoni/prevenção & controle
6.
Acta Trop ; 217: 105863, 2021 May.
Artigo em Inglês | MEDLINE | ID: mdl-33587944

RESUMO

A point-of-care test for detecting schistosome circulating cathodic antigen in urine (POCCCA) has been proposed for mapping infection and defining prevalence thresholds for mass drug administration (MDA). However, there is increasing evidence that POCCCA may yield false-positive results, which requires rigorous specificity evaluation in non-endemic areas. POCCCA was applied in an area known to be free from infection and devoid of any condition for schistosomiasis transmission as part of a multicentre study to evaluate the performance of POCCCA in Brazil's low or potentially endemic settings. Besides POCCCA detection in urine, a search for eggs in stool was performed by Kato-Katz (KK) and Helmintex (HTX) methods. One-hundred-and-seventy-four participants returned urine samples, 140 of which delivered stool samples. All these were HTX-negative for Schistosoma mansoni, and all 118 tested with KK were negative for both S. mansoni and soil-transmitted helminths. POCCCA results from freshly collected urine yielded a specificity of 62.1% (95% CI: 53.6% - 70.2%), taking trace outcomes as positive according to the manufacturer's instructions. Retesting urine from the 140 HTX-negatives after one-year storage at -20 °C with two new POCCCA batches simultaneously yielded significantly different specificities (34.3%; 95%CI: 26.5% - 42.8% and 75.0%; 95% CI: 67.0% - 81.9%). These two batches had a weak agreement (Cohen's kappa: 0.56; 95%CI: 0.44-0.68) among the 174 urine samples retested. At present, POCCCA cannot be recommended either as a cut-off point for MDA or a reliable diagnostic tool for treatment of the infection carriers (selective chemotherapy) in low endemic areas and at final stages of transmission interruption. Manufacturers should be required to optimize production standardization and to assure quality and reproducibility of the test. Extended rigorous performance evaluations by different users from different regions are needed before POCCCA is widely recommended.


Assuntos
Antígenos de Helmintos/sangue , Testes Imediatos , Esquistossomose mansoni/sangue , Esquistossomose mansoni/diagnóstico , Adolescente , Animais , Brasil/epidemiologia , Criança , Fezes/parasitologia , Feminino , Humanos , Masculino , Prevalência , Reprodutibilidade dos Testes , Esquistossomose mansoni/tratamento farmacológico , Esquistossomose mansoni/imunologia , Sensibilidade e Especificidade
7.
Rev Soc Bras Med Trop ; 53: e20200411, 2020.
Artigo em Inglês | MEDLINE | ID: mdl-33027417

RESUMO

INTRODUCTION: Brazil's southernmost state, Rio Grande do Sul (RGS), was considered schistosomiasis-free until 1998 when a low endemic focus was identified in Esteio, a city located next to the capital of RGS. In the last two decades, the control interventions applied in the region have been apparently successful, and the absence of new cases indicated the possibility of interrupted schistosomiasis transmission. The objective of this study was to update the clinical and epidemiological data of schistosomiasis in Esteio. METHODS: We reviewed all 28 individuals diagnosed with the infection since 1997 and a survey was applied to a group of 29 school-aged children residing in Vila Pedreira, one of the most affected neighborhoods. RESULTS: No eggs were detected in fecal samples using the Helmintex method, and all samples were negative for serum antibodies on examination by the western blot technique using the Schistosoma mansoni microsomal antigen (MAMA- WB). In contrast, 23 individuals (79%) tested positive for the cathodic circulating antigen with the point-of-care immunochromatographic test (POC-CCA) on urine samples. Of the 28 formerly infected individuals, only eight were located, of which four tested positive, and four tested negative for serum antibodies using the MAMA-WB technique. CONCLUSIONS: Current adverse conditions for S. mansoni transmission in Esteio and the absence of a confirmed diagnosis suggests that there is (i) a lack of specificity of the POC-CCA test in low endemic settings, and (ii) a high probability that interruption of schistosomiasis has been achieved in Esteio.


Assuntos
Esquistossomose , Animais , Anticorpos Anti-Helmínticos , Brasil , Criança , Humanos
8.
Rev Soc Bras Med Trop ; 53: e20190562, 2020.
Artigo em Inglês | MEDLINE | ID: mdl-32997046

RESUMO

INTRODUCTION: Schistosomiasis is a poverty-related disease that affects people in 78 countries worldwide. This study aimed to evaluate the point-of-care circulating cathodic antigen (POC-CCA) test performance using sensitive parasitological methods as a reference standard (RS) in individuals before and after treatment. METHODS: The RS was established by combining the results of 16 Kato-Katz slides and the Helmintex® method. Positivity rates of the POC-CCA test and Kato-Katz and Helmintex® methods were calculated before treatment and 30 days afterward. Furthermore, the sensitivity, specificity, accuracy, and kappa coefficient before treatment were determined by comparing the methods. The cure rate was defined 30 days after treatment. RESULTS: Among the 217 participants, the RS detected a total of 63 (29.0%) positive individuals. The POC-CCA test identified 79 (36.4%) infections. The evaluation of POC-CCA test performance in relation to the RS revealed a sensitivity of 61.9%, specificity of 74.0%, accuracy of 70.5%, and kappa coefficient of 0.33. Out of the 53 remaining participants after treatment, a total of 45 (81.1%) showed egg negative results, and 8 (18.9%) were egg positive according to the RS. A total of 5 (9.4%) egg-positive and 37 (69.8%) egg-negative individuals were positive by the POC-CCA test. CONCLUSIONS: Our data show that the POC-CCA test has potential as an auxiliary tool for the diagnosis of Schistosoma mansoni infection, yielding better results than 16 Kato-Katz slides from three different stool samples. However, the immunochromatographic test lacks sufficient specificity and sensitivity for verifying the cure rate after treatment.


Assuntos
Schistosoma mansoni/isolamento & purificação , Esquistossomose mansoni/diagnóstico , Animais , Antígenos de Helmintos/sangue , Humanos , Schistosoma mansoni/imunologia , Esquistossomose mansoni/urina , Sensibilidade e Especificidade
9.
PLoS Negl Trop Dis ; 14(7): e0008500, 2020 07.
Artigo em Inglês | MEDLINE | ID: mdl-32730339

RESUMO

Schistosomiasis remains a serious public health problem in tropical regions, affecting more than 250 million people. Sensitive diagnostic methods represent key tools for disease elimination, in particular in areas with low endemicity. Advances in the use of luminol-based chemiluminescent techniques have enabled greater sensitivity and speed in obtaining results in different diagnostic settings. In this study, we developed a luminol-H2O2 chemiluminescence (CL) method to detect Schistosoma mansoni eggs in human fecal sediments processed by the Helmintex (HTX) method. After S. mansoni eggs were incubated with a solution of luminol-H2O2 the light emission was detected and measured by spectrophotometry at 431 nm for 5 min, using detection and counts of eggs by bright field optical microscopy as a reference. CL intensity was found to correlate with different sources and numbers of eggs. Furthermore, our results showed that the CL method can distinguish positive from negative samples with 100% sensitivity and 71% specificity. To our knowledge, this is the first study to report the use of CL for the diagnosis of helminths from fecal samples. The combination of the HTX method with CL represents an important advance in providing a reference method with the highest standards of sensitivity.


Assuntos
Fezes/parasitologia , Peróxido de Hidrogênio/química , Luminol/química , Óvulo , Schistosoma mansoni/isolamento & purificação , Esquistossomose mansoni/diagnóstico , Animais , Humanos , Medições Luminescentes , Camundongos , Esquistossomose mansoni/parasitologia
10.
PLoS Negl Trop Dis ; 12(3): e0006274, 2018 03.
Artigo em Inglês | MEDLINE | ID: mdl-29518081

RESUMO

Control initiatives have successfully reduced the prevalence and intensity of schistosomiasis transmission in several localities around the world. However, individuals that release low numbers of eggs in their feces may not be detected by classical methods that are limited by low sensitivity. Given that accurate estimates of prevalence are key to implementing planning control actions for the elimination of schistosomiasis, new diagnostic tools are needed to effectively monitor infections and confirm transmission interruption. The World Health Organization recommends the Kato-Katz (KK) thick smear as a parasitological test for epidemiological surveys, even though this method has been demonstrated to underestimate prevalence when egg burdens are low. The point-of-care immunodiagnostic for detecting schistosome cathodic circulating antigen (POC-CCA) method has been proposed as a more sensitive substitute for KK in prevalence estimations. An alternative diagnostic, the Helmintex (HTX) method, isolates eggs from fecal samples with the use of paramagnetic particles in a magnetic field. Here, a population-based study involving 461 individuals from Candeal, Sergipe State, Brazil, was conducted to evaluate these three methods comparatively by latent class analysis (LCA). The prevalence of schistosomiasis mansoni was determined to be 71% with POC-CCA, 40.% with HTX and 11% with KK. Most of the egg burdens of the individuals tested (70%) were < 1 epg, thereby revealing a dissociation between prevalence and intensity in this locality. Therefore, the present results confirm that the HTX method is a highly sensitive egg detection procedure and support its use as a reference method for diagnosing intestinal schistosomiasis and for comparative evaluation of other tests.


Assuntos
Antígenos de Helmintos/isolamento & purificação , Enteropatias Parasitárias/diagnóstico , Contagem de Ovos de Parasitas/métodos , Schistosoma mansoni/isolamento & purificação , Esquistossomose mansoni/diagnóstico , Adolescente , Animais , Antígenos de Helmintos/imunologia , Brasil/epidemiologia , Criança , Pré-Escolar , Fezes/parasitologia , Feminino , Humanos , Lactente , Enteropatias Parasitárias/epidemiologia , Enteropatias Parasitárias/parasitologia , Enteropatias Parasitárias/transmissão , Masculino , Sistemas Automatizados de Assistência Junto ao Leito , Saúde da População , Prevalência , Schistosoma mansoni/imunologia , Esquistossomose mansoni/epidemiologia , Esquistossomose mansoni/parasitologia , Esquistossomose mansoni/transmissão , Sensibilidade e Especificidade , Organização Mundial da Saúde , Adulto Jovem
11.
PLoS Negl Trop Dis ; 12(2): e0006232, 2018 02.
Artigo em Inglês | MEDLINE | ID: mdl-29470516

RESUMO

BACKGROUND: In some tropical countries, such as Brazil, schistosomiasis control programs have led to a significant reduction in the prevalence and parasite burden of endemic populations. In this setting, the Kato-Katz technique, as the standard diagnostic method for the diagnosis of Schistosoma mansoni infections, which involves the analysis of two slides from one fecal sample, loses its sensitivity. As a result, a significant number of infected individuals are not detected. The objective of this study was to perform extensive parasitological testing of up to three fecal samples and include a rapid urine test (POC-CCA) in a moderate prevalence area in Northern Minas Gerais, Brazil, and evaluate the performance of each test separately and in combination. METHODS AND FINDINGS: A total of 254 individuals were examined with variants of the standard Kato-Katz technique (up to18 Kato-Katz slides prepared from three fecal samples), a modified Helmintex (30 g of feces), the saline gradient (500 mg of feces), and the POC-CCA methods. We established a reference standard taking into consideration all the positive results in any of the parasitological exams. Evaluation of the parasite burden by two Kato-Katz slides confirmed that most of the individuals harbored a light infection. When additional slides and different parasitological methods were included, the estimated prevalence rose 2.3 times, from 20.4% to 45.9%. The best sensitivity was obtained with the Helmintex method (84%). All parasitological methods readily detected a high or moderate intensity of infection; however, all lost their high sensitivity in the case of low or very low intensity infections. The overall sensitivity of POC-CCA (64.9%) was similar to the six Kato-Katz slides from three fecal samples. However, POC-CCA showed low concordance (κ = 0.34) when compared with the reference standard. CONCLUSIONS: The recommended Kato-Katz method largely underestimated the prevalence of S. mansoni infection. Because the best performance was achieved with a modified Helmintex method, this technique might serve as a more precise reference standard. An extended number of Kato-Katz slides in combination with other parasitological methods or with POC-CCA was able to detect more than 80% of egg-positive individuals; however, the rapid urine test (POC-CCA) produced a considerable percentage of false positive results.


Assuntos
Técnicas de Laboratório Clínico/métodos , Fezes/parasitologia , Doenças Negligenciadas/diagnóstico , Carga Parasitária , Schistosoma mansoni/isolamento & purificação , Esquistossomose mansoni/diagnóstico , Adolescente , Adulto , Idoso , Idoso de 80 Anos ou mais , Animais , Antígenos de Helmintos/urina , Brasil , Criança , Pré-Escolar , Feminino , Humanos , Renda , Masculino , Pessoa de Meia-Idade , Doenças Negligenciadas/epidemiologia , Contagem de Ovos de Parasitas , Sistemas Automatizados de Assistência Junto ao Leito , Prevalência , Esquistossomose/diagnóstico , Esquistossomose mansoni/epidemiologia , Esquistossomose mansoni/urina , Sensibilidade e Especificidade , Fatores Socioeconômicos , Abastecimento de Água , Adulto Jovem
12.
Rev. Soc. Bras. Med. Trop ; 56: e0238, 2023. tab, graf
Artigo em Inglês | LILACS-Express | LILACS | ID: biblio-1422897

RESUMO

ABSTRACT Background: The World Health Organization recommends a market-ready, urine-based point-of-care diagnostic test for circulating cathodic antigens (CCA) to determine the prevalence of S. mansoni. This study evaluated the performance of the URINE CCA (SCHISTO) ECO TESTE® (POC-ECO), which is currently available in Brazil. Methods: Residents from eight sites with different prevalence estimates provided one urine sample for POC-ECO and one stool sample for Kato-Katz (KK) and Helmintex® (HTX) testing as an egg-detecting reference for infection status. Results: None of the study sites had significantly higher POC-ECO accuracy than KK. Conclusions: POC-ECO is not currently recommended in Brazilian schistosomiasis elimination programs.

13.
Int J Parasitol ; 45(1): 43-50, 2015 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-25305086

RESUMO

Schistosomiasis is a chronic parasitic disease of humans, with two species primarily causing the intestinal infection: Schistosoma mansoni and Schistosoma japonicum. Traditionally, diagnosis of schistosomiasis is achieved through direct visualisation of eggs in faeces using techniques that lack the sensitivity required to detect all infections, especially in areas of low endemicity. A recently developed method termed Helmintex™ is a very sensitive technique for detection of Schistosoma eggs and exhibits 100% sensitivity at 1.3 eggs per gram of faeces, enough to detect even low-level infections. The Helminthex™ method is based on the interaction of magnetic microspheres and schistosome eggs. Further understanding the underlying egg-microsphere interactions would enable a targeted optimisation of egg-particle binding and may thus enable a significant improvement of the Helmintex™ method and diagnostic sensitivity in areas with low infection rates. We investigated the magnetic properties of S. mansoni and S. japonicum eggs and their interactions with microspheres with different magnetic properties and surface functionalization. Eggs of both species exhibited higher binding affinity to the magnetic microspheres than the non-magnetic microspheres. Binding efficiency was further enhanced if the particles were coated with streptavidin. Schistosoma japonicum eggs bound more microspheres compared with S. mansoni. However, distinct differences within eggs of each species were also observed when the distribution of the number of microspheres bound per egg was modelled with double Poisson distributions. Using this approach, both S. japonicum and S. mansoni eggs fell into two groups, one having greater affinity for magnetic microspheres than the other, indicating that not all eggs of a species exhibit the same binding affinity. Our observations suggest that interaction between the microspheres and eggs is more likely to be related to surface charge-based electrostatic interactions between eggs and magnetic iron oxide rather than through a direct magnetic interaction.


Assuntos
Adsorção , Magnetismo , Microesferas , Schistosoma japonicum/metabolismo , Schistosoma mansoni/metabolismo , Coloração e Rotulagem , Animais , Testes Diagnósticos de Rotina , Humanos , Camundongos , Esquistossomose/diagnóstico , Eletricidade Estática , Zigoto/metabolismo
14.
Rev. Soc. Bras. Med. Trop ; 53: e20200411, 2020. tab
Artigo em Inglês | SES-SP, Coleciona SUS (Brasil), LILACS | ID: biblio-1136850

RESUMO

Abstract INTRODUCTION: Brazil's southernmost state, Rio Grande do Sul (RGS), was considered schistosomiasis-free until 1998 when a low endemic focus was identified in Esteio, a city located next to the capital of RGS. In the last two decades, the control interventions applied in the region have been apparently successful, and the absence of new cases indicated the possibility of interrupted schistosomiasis transmission. The objective of this study was to update the clinical and epidemiological data of schistosomiasis in Esteio. METHODS: We reviewed all 28 individuals diagnosed with the infection since 1997 and a survey was applied to a group of 29 school-aged children residing in Vila Pedreira, one of the most affected neighborhoods. RESULTS No eggs were detected in fecal samples using the Helmintex method, and all samples were negative for serum antibodies on examination by the western blot technique using the Schistosoma mansoni microsomal antigen (MAMA- WB). In contrast, 23 individuals (79%) tested positive for the cathodic circulating antigen with the point-of-care immunochromatographic test (POC-CCA) on urine samples. Of the 28 formerly infected individuals, only eight were located, of which four tested positive, and four tested negative for serum antibodies using the MAMA-WB technique. CONCLUSIONS: Current adverse conditions for S. mansoni transmission in Esteio and the absence of a confirmed diagnosis suggests that there is (i) a lack of specificity of the POC-CCA test in low endemic settings, and (ii) a high probability that interruption of schistosomiasis has been achieved in Esteio.


Assuntos
Humanos , Animais , Criança , Esquistossomose , Brasil , Anticorpos Anti-Helmínticos
15.
Rev. Soc. Bras. Med. Trop ; 53: e20190562, 2020. tab, graf
Artigo em Inglês | SES-SP, Coleciona SUS (Brasil), LILACS | ID: biblio-1136886

RESUMO

Abstract INTRODUCTION Schistosomiasis is a poverty-related disease that affects people in 78 countries worldwide. This study aimed to evaluate the point-of-care circulating cathodic antigen (POC-CCA) test performance using sensitive parasitological methods as a reference standard (RS) in individuals before and after treatment. METHODS The RS was established by combining the results of 16 Kato-Katz slides and the Helmintex® method. Positivity rates of the POC-CCA test and Kato-Katz and Helmintex® methods were calculated before treatment and 30 days afterward. Furthermore, the sensitivity, specificity, accuracy, and kappa coefficient before treatment were determined by comparing the methods. The cure rate was defined 30 days after treatment. RESULTS Among the 217 participants, the RS detected a total of 63 (29.0%) positive individuals. The POC-CCA test identified 79 (36.4%) infections. The evaluation of POC-CCA test performance in relation to the RS revealed a sensitivity of 61.9%, specificity of 74.0%, accuracy of 70.5%, and kappa coefficient of 0.33. Out of the 53 remaining participants after treatment, a total of 45 (81.1%) showed egg negative results, and 8 (18.9%) were egg positive according to the RS. A total of 5 (9.4%) egg-positive and 37 (69.8%) egg-negative individuals were positive by the POC-CCA test. CONCLUSIONS Our data show that the POC-CCA test has potential as an auxiliary tool for the diagnosis of Schistosoma mansoni infection, yielding better results than 16 Kato-Katz slides from three different stool samples. However, the immunochromatographic test lacks sufficient specificity and sensitivity for verifying the cure rate after treatment.


Assuntos
Humanos , Animais , Schistosoma mansoni/isolamento & purificação , Esquistossomose mansoni/diagnóstico , Schistosoma mansoni/imunologia , Esquistossomose mansoni/urina , Sensibilidade e Especificidade , Antígenos de Helmintos/sangue
16.
Mem. Inst. Oswaldo Cruz ; 114: e180529, 2019. tab, graf
Artigo em Inglês | LILACS | ID: biblio-1040608

RESUMO

Helmintex is a sensitive method used for detecting Schistosoma mansoni eggs. Here, we describe the observed frequency of six proposed criteria associated with the identification of S. mansoni eggs prepared with the Helmintex method and stained with ninhydrin. The efficacy of these criteria in classifying S. mansoni eggs when applied in various combinations was also examined. Nine observers registered the presence or absence of 6 different criteria in 100 eggs using a microscope at 100x magnification. Ninhydrin purple, which was frequently observed, was the criterion associated with the lowest inter-observer variability. At least three criteria were associated with a significantly better performance in egg identification. In conclusion, ninhydrin staining and a combination of criteria are recommended for microscope examination of faecal sediments.


Assuntos
Animais , Óvulo/citologia , Contagem de Ovos de Parasitas/métodos , Schistosoma mansoni/isolamento & purificação , Fezes/parasitologia , Indicadores e Reagentes , Ninidrina , Contagem de Ovos de Parasitas/normas , Valores de Referência , Reprodutibilidade dos Testes
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA